Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Porosity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

Fused deposition modeling of novel scaffold architectures for tissue engineering applications.

Fused deposition modeling, a rapid prototyping technology, was used to produce novel scaffolds with honeycomb-like pattern, fully interconnected channel network, and controllable porosity and channel size. A bioresorbable polymer poly(epsilon-caprolactone) (PCL) was developed as a filament modeling material to produce porous scaffolds, made of layers of directionally aligned microfilaments, using this computer-controlled extrusion and deposition process. The PCL scaffolds were produced with a range of channel size 160-700 microm, filament diameter 260-370 microm and porosity 48-77%, and regular geometrical honeycomb pores, depending on the processing parameters. The scaffolds of different porosity also exhibited a pattern of compressive stress-strain behavior characteristic of porous solids under such loading. The compressive stiffness ranged from 4 to 77 MPa, yield strength from 0.4 to 3.6 MPa and yield strain from 4% to 28%. Analysis of the measured data shows a high correlation between the scaffold porosity and the compressive properties based on a power-law relationship.

Anisotropy↗

Microstructural dependence of Young's and shear moduli of P2O5 glass reinforced hydroxyapatite for biomedical applications.

P2O5 glass reinforced hydroxyapatite composite materials were prepared through a liquid-phase sintering process. Secondary phases, beta- and alpha-tricalcium phosphates (beta-TCP and alpha-TCP), were formed in the microstructure of the composites, due to the reaction between the liquid glassy phase and the hydroxyapatite matrix. The dynamic Young's modulus (E) and shear modulus (G) of these composites were determined using an impulse excitation method. By applying the Duckworth-Knudsen equation, the elastic property results were correlated with the relative proportion of beta-TCP and alpha-TCP phases and with the porosity percentage present in the microstructure. Glass reinforced hydroxyapatite composites showed lower Young's and shear moduli than unmodified hydroxyapatite, mainly due to the presence of beta-TCP phase. The Duckworth-Knudsen model demonstrated an exponential dependence of E and G modulus with porosity and mathematical equations were derived for composite materials with porosity correction factors (b) of 4.04 and 4.11, respectively, indicating that porosity largely decreased both E and G moduli.

Biocompatible Materials↗

Growth substrates made from duck excreta enriched wood shavings and source-separated municipal solid waste compost and separates: physical and chemical characteristics.

Production and use of compost is an effective means to reduce wastes, and offers a large potential as growth substrates and source of nutrients. The objective of this study was to determine the physical and chemical characteristics of duck excreta enriched wood shavings (DMC) and source-separated municipal solid waste (MSW) composts and separates, and to assess the physical characteristics of growth substrates made from these two composts and selected substrates. MSW compost separates were the following sizes: F1 > 4 mm diameter, 2 mm < F2 < 4 mm, 1 mm < F3 < 2 mm and F4 < 1 mm. Growth substrates were prepared by mixing DMC and F2 and F3 MSW separates (M/M ratios). Growth substrates A-E consisted exclusively of 10-60% DMC and 20-60% of MSW separates F2 and F3. Growth substrates F-J, and K-O were the same as substrates A E, with 15% M/M brick fragments or shredded plastic added as porosity agents, respectively. Growth substrates (BE/S) made of black earth (BE) and sandy loam soil (Ls) in a 1:4 (M/M) ratio, commercially available peat substrate (Pr) and an in-house sphagnum peat-based substrate (Gs) were used for comparison. Principal component analysis (PCA) showed that DMC was a better material than MSW with respect to porosity and water field capacity. MSW compost and separates differed by their relatively high levels of water-soluble and HCl-hydrolyzable N and increased advantageous water retention capacity. PCA also showed that substrates A-E exhibited porosity and water field capacity similar to those of Pr. Substrates F-J had porosity and water field capacity similar to those of BE/S, whereas substrates K O were more similar to Pr and to substrates A and B. The presented data indicate that DMC and MSW separates were complementary in providing good physical and chemical characteristics to the growth substrates.

Agriculture↗

Characterization of the surface interacting ability of carbon black by means of electron paramagnetic resonance analysis of adsorbed Cu2+, supported by surface analysis and atomic absorption.

Electron paramagnetic resonance (EPR) has been used to investigate the adsorption capability and the surface interacting ability towards Cu(II) solutions (CuCl2, Cu(NO3)2, CuSO4 in water or ethanol) of various carbon blacks, both graphitized and ungraphitized, selected on the basis of the surface area, namely, Carbograph1 (area = 100 m2/g), Carbograph4 (area = 210 m2/g), and Carbograph5 (area = 560 m2/g), which were indicated as C1g, C4g, C5g (g = graphitized), and C1ng, C4ng, C5ng (ng = ungraphitized). The EPR analysis was supported by surface analysis, for evaluating the surface area, the pore volume and the porosity, and by atomic absorption to obtain the adsorbed Cu(II) amounts. Graphitization provokes a decrease in surface area, but C1g, at low surface area, showed a unexpected increase of the adsorption ability ascribed to the formation of new surface porosity closed by graphite layers. The carbon samples showed a broad unresolved EPR signal due to mobile unpaired electrons in the carbon matrix. Graphitized samples presented a narrower signal than ungraphitized samples, which increases in width with the increase in surface area (with the exception of C5ng due to the high exposition of the wide surface to oxydizing external agents) and upon prolonged thermal treatment. The signal intensity of the carbon paramagnetic centers decreases upon Cu(II) adsorption. Computer aided analysis of the EPR spectra of the solids after Cu(II) adsorption allowed to extract structural information on the Cu-surface site complexes. The Cu2+ ions coordinated with surface polar sites, mainly oxygenated. Adsorption depends on the different Cu(II) salts, caused by the salt solubility and the interacting ability of the counter-ion. In several cases the solutions concentrated in the carbon porosity leading to precipitation of the salt. Ethanol solutions are more adsorbed at the carbon surface than water solutions; Cu(II) partially retains its solvation shell and partially presents electron transfer to the carbon surface. Adsorption is favored to ungraphitized carbons with respect to the graphitized ones due to both the higher surface area, and the higher hydrophilicity of the surface. In summary, these carbon powders, widely used for chromatographic applications, show an adsorption capability towards Cu(II) solutions higher than expected due to both a definite porosity, and the presence of polar groups which are not eliminated with chemical surface treatments.

Carbon↗

Controlled-release NPK fertilizer encapsulated by polymeric membranes.

The commercial granular fertilizer NPK6-20-30 was coated using polysulfone (PSF), polyacrylonitrile (PAN), and cellulose acetate (CA). The coatings were formed from the polymer solutions by the phase inversion technique. Measurements of the thickness and porosity of the prepared coatings and a microphotographic observation of the coatings were performed. The physical properties of the coatings influence the release rate of macronutrients which are present in the core of the coated fertilizer. In the case of PAN coating with 60.45% porosity, prepared from a 16% polymer solution, 100% of NH(4)(+) and P(2)O(5) was released after 4 h of test and 99.7% of K(+) after 5 h of test, whereas in the case of coating with 48.8% porosity, 31.8% of NH(4)(+), 16.7% of P(2)O(5), and 11.6% of K(+) was released after 5 h. In all experiments, different selectivities of the coatings in terms of the release of components were observed. The release of potassium through the coatings made of PSF and PAN was the slowest. The same tendency was observed for the release of nitrogen through a coating of CA. The release of fertilizer active components was the slowest in the case of PSF. The lowest porosity coating was prepared from the 18% PSF solution.

Chemical Phenomena↗

Molecular tectonics. Porous hydrogen-bonded networks built from derivatives of 9,9'-spirobifluorene.

Molecules with multiple sites that induce strong directional association tend to form open networks with significant volumes available for the inclusion of guests. Such molecules can be conveniently synthesized by grafting diverse sticky sites onto geometrically suitable cores. The characteristic inability of 9,9'-spirobifluorene to form close-packed crystals suggests that it should serve as a particularly effective core for the elaboration of molecules designed to form highly porous networks. To test this hypothesis, various new tetrasubstituted 9,9'-spirobifluorenes with hydrogen-bonding sites at the 3,3',6,6'-positions or 2,2',7,7'-positions were synthesized by multistep routes. Four of these compounds were crystallized, and their structures were determined by X-ray crystallography. In all cases, the compounds form extensively hydrogen-bonded networks with high porosity. In particular, 43% of the volume of crystals of 3,3',6,6'-tetrahydroxy-9,9'-spirobifluorene (28) is available for the inclusion of guests, whereas the porosity is only 28% in crystals of tetrakis(4-hydroxyphenyl)methane, a close model that lacks the spirobifluorene core. Similarly, the porosities found in crystals of 2,2',7,7'-tetra(acetamido)-9,9'-spirobifluorene (33) and 2,2',7,7'-tetrasubstituted tetrakis(diaminotriazine) 39 are 33% and 60%, respectively. Moreover, the porosity of crystals of 2,2',7,7'-tetrasubstituted tetrakis(triaminotriazine) 40 is 75%, the highest value yet observed in crystals built from small molecules. These observations demonstrate that a particularly effective strategy for engineering molecules able to form highly porous networks is to graft multiple sticky sites onto spirobifluorenes or other cores intrinsically resistant to close packing.

Journal Article↗

Porous ceramic bodies for drug delivery.

An approach to the production of ceramic drug delivery devices is proposed. Two examples of possible ceramics are dealt with: hydroxyapatite weakly modifiable by living tissue and the bioinert alumina. The possibility to control the formed porosity was taken into consideration for both materials. The ratio between the acquired porosity and the quantity and quality of the agents inducing porosity is also described and discussed. A test on the role of porosity was performed on the obtained porous ceramic bodies and a study was made on the release of a substance with pharmacological activity from previously impregnated porous ceramic bodies. This paper is preliminary to a planned work targeted to the preparation of ceramic drug delivery systems.

Journal Article↗

Numerical simulation of the casting process of titanium tooth crowns and bridges.

The objectives of this paper were to simulate the casting process of titanium tooth crowns and bridges; to predict and control porosity defect. A casting simulation software, MAGMASOFT, was used. The geometry of the crowns with fine details of the occlusal surface were digitized by means of laser measuring technique, then converted and read in the simulation software. Both mold filling and solidification were simulated, the shrinkage porosity was predicted by a "feeding criterion", and the gas pore sensitivity was studied based on the mold filling and solidification simulations. Two types of dental prostheses (a single-crown casting and a three-unit-bridge) with various sprue designs were numerically "poured", and only one optimal design for each prosthesis was recommended for real casting trial. With the numerically optimized design, real titanium dental prostheses (five replicas for each) were made on a centrifugal casting machine. All the castings endured radiographic examination, and no porosity was detected in the cast prostheses. It indicates that the numerical simulation is an efficient tool for dental casting design and porosity control.

Journal Article↗

Effect of compaction temperature on consolidation of amorphous copolymers with different glass transition temperatures.

PURPOSE: The purpose of this study was to relate the combination of glass transition temperature (Tg) and temperature of measurement with the mechanical and compaction properties of some test materials. METHODS: Copolymers with different Tg'S were synthesised by free radical copolymerisation of methyl methacrylate with lauryl methacrylate. Elastic moduli were measured by dynamic mechanical analysis at different strain rates and temperatures. Compaction experiments were performed at different compaction speeds and temperatures. RESULTS: The difference between temperature of measurement and Tg appears to determine both elastic modulus and yield strength completely. They both decrease with decreasing difference between temperature of measurement and Tg and increase with strain rate. At temperatures of measurement higher than the Tg the elastic modulus is extremely low because the materials behave as rubbers. Consequently, the amount of energy stored during compaction decreases when the compaction temperature approaches the Tg and increases with strain rate. When the compaction temperature is higher than the Tg, the amount of stored energy is extremely large. The compaction experiments show that the final tablet porosity is completely determined by stress relaxation phenomena. Consequently, the final tablet porosity follows exactly the same relation as that of stored energy. CONCLUSIONS: The final tablet porosity is unequivocally determined by the amount of stored energy. This implies that tablet production at a temperature of about 20 K under the glass transition temperature of the material yields tablets with minimum porosity.

Glass↗

A theoretical analysis of low-frequency sonophoresis: dependence of transdermal transport pathways on frequency and energy density.

PURPOSE: Application of low-frequency ultrasound has been shown to increase skin permeability, thereby facilitating delivery of macromolecules (low-frequency sonophoresis). In this study, we seek to determine the dependence of transport pathways during low-frequency sonophoresis on ultrasound parameters. METHODS: Pig skin is exposed to low-frequency ultrasound over a range of frequencies to achieve different skin resistivities. The porous pathway model is used to study the dependence of average pore size, porosity, and tortuosity on ultrasound parameters. Imaging experiments are also carried out to visualize the transport pathways created by ultrasound. RESULTS: The data show that the average pore size, determined from the porous pathway model, does not depend on application frequency. Both in the presence and absence of ultrasound the average pore size determined from mannitol delivery is the same (28 +/- 12 A). With the application of ultrasound the skin porosity could be increased by up to 1700-fold. The effect of ultrasound on skin is heterogeneous thereby creating localized transport pathways (LTP). The porosity of these transport pathways is of the same order of magnitude as that of the dermis. CONCLUSIONS: With this study it is shown that low-frequency ultrasound increases skin permeability by increasing skin porosity rather than by increasing the size of the pores that are responsible for permeant delivery.

Administration, Cutaneous↗

Clinical experience with a new collagen-coated Dacron double-velour prosthesis.

Vascular grafts with primary zero porosity are desirable in surgery for aortic aneurysms with intraoperative partial or total systemic heparinization of the patient. The present study describes the clinical application and results of a new knitted Dacron double-velour prosthesis (primary porosity: 1,400 cc/min/cm2), coated with cross-linked bovine collagen; the resulting porosity for implantation is O cc/min/cm2. Such grafts were implanted in 111 patients between 12/83 and 11/84: for replacement of the infrarenal aorta in 74 aneurysms, for replacement of the thoraco-abdominal aorta in 4 instances, and for replacement of 13 aneurysms of the descending aorta. In 20 patients with arterial occlusive disease, the prosthesis was employed as bifurcation graft. In 43 cases (38%) the underlying disease was a ruptured (26) or symptomatic aortic aneurysm requiring emergency operation. There was no leakage from any of the implanted grafts regardless of whether partial (100 units/kg BW) or total (300 units/kg BW) systemic heparinization was administered. The overall mortality rate was 11.7% (13/111). For cases of ruptured abdominal aortic aneurysm the mortality rate was 22.7% (5/22). There was no graft-related complication either in the early postoperative course or during the follow-up period (1 to 10 months, mean: 6.2 months). It is concluded that this new type of graft combines the advantages of knitted Dacron prostheses in respect to healing and incorporation with primary zero porosity, and is therefore the graft of choice in surgery for ruptured aortic aneurysm.

Adult↗

Porous poly(propylene fumarate) foam coating of orthotopic cortical bone grafts for improved osteoconduction.

A porous biodegradable scaffold coating for perforated and demineralized cortical bone allografts could maintain immediate structural recovery and subsequently allow normal healing and remodeling by promoting bony ingrowth and avoiding accelerated graft resorption. This new type of osteoconductive surface modification should improve allograft incorporation by promoting new bone growth throughout the biodegradable scaffold, hence encasing the graft with the recipient's own bone. We investigated the feasibility of augmenting orthotopically transplanted cortical bone grafts with osteoconductive biodegradable polymeric scaffold coatings. Five types of bone grafts were prepared: type I, untreated fresh-frozen cortical bone grafts (negative control); type II, perforated and partially demineralized cortical bone grafts without additional coating (positive control); type III, perforated and partially demineralized cortical bone coated with a low-porosity poly(propylene fumarate) (PPF) foam; type IV, perforated and partially demineralized cortical bone coated with a medium-porosity PPF foam; and type V, perforated and partially demineralized cortical bone coated with a high-porosity PPF foam. Grafts were implanted into the rat tibial diaphysis. Fixation was achieved with an intramedullary threaded K-wire. Two sets of animals were operated on. Animals were killed in groups of eight with one set being killed 12 weeks, and the other 16 weeks, postoperatively. Radiographic, histologic, and histomorphometric analyses of grafts showed that the amount of new bone forming around the foam-coated grafts was significantly higher than that in the type I control group (uncoated) or that in type II group (perforated and partially demineralized cortical bone grafts). Although all foam formulations appeared initially equally osteoconductive, histologic evaluation of medium-porosity PPF foam-based coatings appeared to result in a sustained response 16 weeks postoperatively. Significant resorption was present in perforated and partially demineralized cortical bone graft allografts, with some accompanying new bone formation occurring primarily within the laser holes. Therefore, PPF foam-coated cortical bone grafts appeared to be better protected from excessive bone resorption, as frequently seen with invasion of fibrovascular tissue. Biomechanical analysis of the PPF foam-coated grafts corroborated findings of the morphometric analysis in that the failure strength at the allograft-host bone junction sites of all PPF-coated cortical bone grafts was higher than in the uncoated controls.

Animals↗

Aerenchyma and an inducible barrier to radial oxygen loss facilitate root aeration in upland, paddy and deep-water rice (Oryza sativa L.).

The present study evaluated waterlogging tolerance, root porosity and radial O(2) loss (ROL) from the adventitious roots, of seven upland, three paddy, and two deep-water genotypes of rice (Oryza sativa L.). Upland types, with the exception of one genotype, were as tolerant of 30 d soil waterlogging as the paddy and deep-water types. In all but one of the 12 genotypes, the number of adventitious roots per stem increased for plants grown in waterlogged, compared with drained, soil. When grown in stagnant deoxygenated nutrient solution, genotypic variation was evident for root porosity and rates of ROL, but there was no overall difference between plants from the three cultural types. Adventitious root porosity increased from 20-26 % for plants grown in aerated solution to 29-41 % for plants grown in stagnant solution. Growth in stagnant solution also induced a 'tight' barrier to ROL in the basal regions of adventitious roots of five of the seven upland types, all three paddy types, and the two deep-water types. The enhanced porosity provided a low resistance pathway for O(2) movement to the root tip, and the barrier to ROL in basal zones would have further enhanced longitudinal O(2) diffusion towards the apex, by diminishing losses to the rhizosphere. The plasticity in root physiology, as described above, presumably contributes to the ability of rice to grow in diverse environments that differ markedly in soil waterlogging, such as drained upland soils as well as waterlogged paddy fields.

Adaptation, Physiological↗

Swelling properties of various polymers used in controlled release systems.

The effect of powder packing and porosity of specimens on the swelling properties of polymeric materials was studied, in various swelling liquids, such as distilled water and 0.1 N hydrochloric acid solution. Capsules, tablets and films of hydroxypropyl methylcellulose, poly(ethylene oxide) and sodium alginate were prepared, and their weight uptake after immersion into the above solutions was recorded as a function of time, in order to assess the swelling process. Measurements of some characteristics of the as-received powders were also performed in an attempt to classify the specimens prepared according to their porosity. Within the experimental conditions of this work, it was shown that the porosity of polymeric specimens is a dominant factor that controls their swelling behaviour. Increased porosity leads to fast initial rates of weight uptake and high extent of equilibrium swelling. On the other hand, dissolution and possible degradation of polymers susceptible to acid hydrolysis results in some variations from the above mentioned behaviour. With respect to the application in controlled release systems, the overall delivery rate from a polymeric specimen is expected to be a function of both swelling and disintegration characteristics of a specimen, and therefore, the weight uptake can be considered a measure of the release only in the case of polymers with low water solubility and increased stability to hydrolysis.

Biocompatible Materials↗

Swelling properties of various polymers used in controlled release systems.

The effect of powder packing and porosity of specimens on the swelling properties of polymeric materials was studied, in various swelling liquids, such as distilled water and 0.1 N hydrochloric acid solution. Capsules, tablets and films of hydroxypropyl methylcellulose, poly(ethylene oxide) and sodium alginate were prepared and their weight uptake after immersion into the above solutions was recorded as a function of time, in order to assess the swelling process. Measurements of some characteristics of the as received powders were also performed as an attempt to classify the specimens prepared according to their porosity. Within the experimental conditions of this work, it was shown that the porosity of polymeric specimens is a dominant factor that controls their swelling behaviour. Increased porosity leads to fast initial rates of weight uptake and high extent of equilibrium swelling. On the other hand, dissolution and possible degradation of polymers susceptible to acid hydrolysis, results in some variations from the above-mentioned behaviour. With respect to the application in controlled release systems, the overall delivery rate from a polymeric specimen is expected to be a function of both swelling and disintegration characteristics of a specimen and, therefore, the weight uptake can be considered a measure of the release only in the case of polymers with low water solubility and increased stability to hydrolysis.

Drug Delivery Systems↗

Femoral bone adaptation to unstable long-term cemented total hip arthroplasty in dogs.

OBJECTIVE: To evaluate femoral adaptation after unstable long-term cemented total hip arthroplasty (cTHA) in dogs. STUDY DESIGN: Clinical study. ANIMALS: Four dogs. METHODS: Paired femurs were examined from client-owned dogs that were donated to a retrieval program after death from causes unrelated to their cTHA. Mean (+/-SEM) dog age was 10.0+/-1.5 years and implant duration was 6.0+/-1.4 years. Implanted femurs had radiographic changes associated with implant loosening and gross mechanical instability at femur retrieval. Femurs were evaluated at 3 levels relative to implant length. Cortical area and medullary area were measured at each level, and cortical porosity was assessed at each level in 4 quadrants and in 3 regions. Implanted femurs were compared with the contralateral non-implanted femurs. RESULTS: Cortical area and cortical porosity were increased at all levels in femurs with unstable implants. Implanted femurs had increased porosity in all quadrants and regions at the proximal 2 levels, and increased porosity in only the cranial quadrant and mid-cortical area at the distal level, when compared with contralateral non-implanted femurs. Corresponding medullary areas were not different. CONCLUSIONS: Significant histomorphometric changes occur in femurs after unstable cTHA. The patterns of periosteal bone formation and endosteal bone resorption support mechanisms of stress shielding and wear debris-mediated osteolysis as factors that may contribute to femoral adaptation and implant loosening. CLINICAL RELEVANCE: Despite popularity and excellent return to function with cTHA, aseptic loosening remains a serious long-term complication. Substantial net bone loss and unfavorable environment with unstable cTHA may make revision surgery less successful.

Animals↗

In vitro acoustic waves propagation in human and bovine cancellous bone.

UNLABELLED: The acoustic behavior of cancellous bone with regard to its complex poroelastic nature has been investigated. The existence of two longitudinal modes of propagation is demonstrated in both bovine and human cancellous bone. Failure to take into account the presence of these two waves may result in inaccurate material characterization. INTRODUCTION: Acoustic wave propagation is now a commonly used nondestructive method for cancellous bone characterization. However, wave propagation in this material may be affected by fluid-solid interactions inherent to its poroelastic nature, resulting in two different longitudinal waves. This phenomenon has been demonstrated in previous studies and is in agreement with Biot's theory. The purpose of this paper is to extend these findings to human trabecular bone and to thoroughly investigate these two waves. MATERIALS AND METHODS: Sixty human and 14 bovine cancellous bone cubic specimens were tested in vitro in three different directions using an immersion acoustic transmission method. Original procedures were developed to quantify both velocity and attenuation characteristics of each wave. In term of attenuation, a modified broadband ultrasound attenuation (BUA), describing the rate of change of the frequency-dependent attenuation, was defined for each wave (FDUA). RESULTS: Both waves were identified in most of the specimens. The fast wave velocities demonstrated a negative linear correlation with porosity (1500-2300 m/s, R2 = 0.44, p < 10(-3)), whereas the slow wave velocities exhibited two different behaviors: (1) a first set of data clearly dependent on porosity showing a positive linear correlation (1150-1450 m/s, R2 = 0.26, p < 10(-3)) and (2) a second group independent on porosity. The fast wave FDUA (20-140 dB/cmMHz) showed a parabolic behavior and reached a maximum for 75% porosity (second degree relationship R2 = 0.41,p < 10(-3)), whereas a positive linear behavior was observed for the slow wave FDUA (15-40 dB/cmMHz; R2 = 0.15, p < 10(-2)). CONCLUSIONS: Existence of two wave propagation modes were demonstrated in human cancellous bone. Our data suggest that, in some cases, the amplitude of the slow wave is much larger than the amplitude of the fast wave. For this reason, care should be taken when using measurement systems that incorporate simple threshold detection because the fast wave could remain undetected. Moreover, failure to consider the presence of these two waves could result in an inaccurate quantification of cancellous bone physical properties.

Acoustics↗

[Studies on the application of apatite to dental materials. (I) --Apatite ceramics-- (author's transl)].

Apatite ceramics is composed of hydroxyapatite [Ca10(PO4)6(OH)2] sintered at high temperature. It is known that hydroxyapatite is the main component of bone and tooth minerals. There are two synthetic methods for the apatite powder. One is so called wet synthetic method: Synthesis by the reaction of Ca++ and PO4--- in the aqueous solution of approximately pH 7.0, the other is dry method: Synthesis by the solid state reaction at high temperature. The apatite powder stable below 1400 degrees C was prepared by the latter method in this work. After passing through a sieve, this powder was cold-pressed and then sintered at 1000 degrees C to 1300 degrees C in air. Biological apatite powders were also perpared as a reference. It was found that any apatite ceramics having porosity in the range of 5 to 50% could be obtained under the various sintering conditions. Compressive strength of these apatite ceramics increased with the reduction of the porosity, and those with porosity less than 20% were more than 100 kg/cm2. Vickers hardness was measured. This result showed the same tendency as that of compressibility. Hardness of the apatite ceramics with 90% relative density was almost the same or more as that of enamel. Solubility of the synthetic apatite powder in distilled water and aqueous solution of lactic acid (pH 4.0) was nearly the same as biological apatites. The dissolution rate decreased with the reduction of porosity of the ceramics. It was certified that hot pressing technique was extremely effective to obtain high density ceramics (more than 95% of density) and thus low parosity apatite ceramics. From the facts as described above, it is understood that sintered pure hydroxy-apatite is an excellent ceramics of high mechanical strength.

Apatites↗