Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “LARYNGOSCOPY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

Short thyromental distance: a predictor of difficult intubation or an indicator for small blade selection?

BACKGROUND: Short thyromental distance (TMD; < 5 cm) has been correlated with difficult direct laryngoscopic intubation in adult patients. The authors hypothesized that a smaller Macintosh curved blade (No. 2 MCB) would improve the predicted difficult laryngoscopy in short-TMD patients over that with a standard Macintosh curved blade (No. 3 MCB). METHODS: In a preliminary study of 11 consenting adults (7 females and 4 males), American Society of Anesthesiologists physical status I and TMD < or = 5 cm, lateral neck radiographs were recorded during laryngoscopy with a No. 2 and No. 3 MCB in sequential fashion. In a prospective clinical study, laryngoscopy and tracheal intubation were evaluated in 83 adult patients with TMD < or = 5 cm by randomly assigning them to two groups for the blade used at first intubation. Those who failed intubation with the first blade were switched to the alternate blade. In total 100 laryngoscopies and intubations were performed: the No. 2 MCB (n = 50) and the No. 3 MCB (n = 50). RESULTS: Lateral neck radiographs recorded at the best laryngeal view revealed that the tip of the No. 2 MCB was proximal to the hyoid body with the No. 2 MCB and distal to it with the No. 3 MCB. The intubation distance (C5 to blade tip) on neck radiographs with the No. 2 MCB was significantly greater than it was with the No. 3 MCB for similar anterior jaw displacement. In the clinical study, the laryngoscopic grade with the No. 2 blade was considered easy (median, 2B), better than the grade with the No. 3 MCB (median, 3). When the No. 2 MCB was used, external laryngeal pressure improved the laryngoscopic grade (1, full glottic view) in 46% of patients. In contrast, when the No. 3 MCB was used, pressure improved the grade in only 10% of the patients. Intubation time with the No. 2 MCB was significantly (P < 0.05) less than it was in patients with No. 3 MCB. Overall, 14 patients who failed intubation with the No. 3 MCB were switched to the No. 2 MCB, and intubation was successful with an easy laryngoscopic grade. Three patients who failed intubation with the No. 2 MCB were switched to the No. 3 MCB. CONCLUSIONS: The predicted difficult laryngoscopy and intubation with the use of the adult No. 3 MCB in standard adult patients with a TMD < or = 5 cm is significantly easier with use of the smaller No. 2 MCB.

Adolescent↗

A pilot study of autofluorescent endoscopy for the in vivo detection of laryngeal cancer.

OBJECTIVES: To determine the advantage of autofluorescent endoscopy for the identification of laryngeal cancer. STUDY DESIGN: This is a prospective, multicenter clinical study. We investigated whether autofluorescent endoscopy using the Lung Imaging Fluorescent Endoscopy (LIFE)-Lung System (Xillix, Olympus) is capable of identifying early cancer of the larynx, especially in comparison with conventional white-light endoscopy and microscopic laryngoscopy. Benign lesions as well as microinvasive and invasive squamous cell carcinoma of the larynx were investigated. For logistic reasons and because of the pilot character of this study, the number of patients was limited. METHODS: Sixteen patients having 24 laryngeal lesions of both benign or malignant character were subsequently examined by autofluorescent endoscopy, white-light endoscopy, and microscopic laryngoscopy. Based on optical appearance, and for each method separately, the lesions were classified as malignant or not. The visual results were documented and histologically verified. RESULTS: The sensitivity of autofluorescent endoscopy for laryngeal cancer detection was more than 90% and therefore higher than that of white-light endoscopy and microscopic laryngoscopy. However, as far as laryngeal cancer is concerned, the specificity of autofluorescent endoscopy was very low. Many of the false-positive results were due to inflammation, hypervascularization, and edema. CONCLUSION: Autofluorescent endoscopy is advantageous only in the hands of an experienced ENT specialist. Although it does not replace the combination of white-light endoscopy and a critical evaluation of the clinical symptoms of the individual disease, it can profitably complement them. Autofluorescent endoscopy can help in determining whether microscopic laryngoscopy performed with general anesthesia should be recommended urgently to the patient. Microscopic laryngoscopy remains the best method for the identification of malignant lesions, if it is combined with obtaining taking multiple biopsy specimens. Confirmation of the results of this pilot study with a larger series of patients is desirable.

Adult↗

Methacholine challenge testing in the diagnosis of paradoxical vocal fold motion.

OBJECTIVE: The purpose of this study was to determine whether methacholine challenge testing (MCT) combined with serial laryngoscopy could elicit and visualize paradoxical vocal fold motion (PVFM) during asymptomatic periods and suggest laryngeal dysfunction as an etiology of episodic dyspnea. STUDY DESIGN: A retrospective study of seven adult patients. METHODS: Medical records of seven adult patients who were referred to an otolaryngology clinic with recurrent episodes of dyspnea or choking and underwent bronchoprovocation testing were reviewed. After initial fiberoptic laryngoscopy and pulmonary function testing (PFT), bronchoprovocation was performed using aerosolized methacholine at increasing concentrations. Each administration was followed by repeated laryngoscopy and PFT. A positive endoscopic test was marked by the visualization of paradoxical adduction of the true vocal folds during inspiration. A positive bronchoprovocation test was marked by a 20% or greater decline in the forced expiratory volume. RESULTS: All seven patients demonstrated normal upper airway anatomy and function on initial laryngoscopy. In three patients, a positive endoscopic examination demonstrating PVFM was elicited during MCT. In three, the bronchoprovocation test was positive, and asthma was diagnosed. In one patient, both tests were negative. PVFM was seen in all patients whose chief complaint was choking (n = 2) but in only one of five patients whose chief complaint was dyspnea. CONCLUSIONS: PVFM may be elicited and observed during MCT coupled with serial laryngoscopy. This test holds promise in differentiating vocal cord dysfunction from asthma during asymptomatic periods in patients who present with recurrent episodes of refractory dyspnea.

Administration, Inhalation↗

Comparison of two methods for predicting difficult intubation in obstetric patients.

Preoperative airway assessment for prediction of difficult laryngoscopy and intubation was done using the modified Mallampati test and Wilson risk sum score in three hundred and seventy two obstetric patients undergoing elective as well as emergency Cesarean section under general anesthesia. 25 (6.7%) patients had laryngoscopy grade III or IV of whom 24 (6.4%) patients were difficult at tracheal intubation. Mallampati class III or IV predicted 15 of the 23 patients while Wilson risk sum score > or = 2 predicted 9 of the 14 patients in whom tracheal intubation was difficult. As a screening test for prediction of difficult intubation Wilson risk sum score was less sensitive (36%) but had almost same specificity (98.5%) and positive predictive value (64%) in comparison to modified Mallampati test (62.5%, 97.7% and 65% respectively). When used as a predictor of difficult laryngoscopy sensitivity, specificity and positive predictive value for modified Mallampati test were 60%, 97.6% and 65% respectively and for Wilson risk sum they were 36%, 98.5% and 64% respectively, but when both tests were combined as predictors (with either of tests positive) sensitivity improved to 100% while specificity was marginally decreased to 96.2% and positive predictive value (64.8%) remained almost the same. There was no significant association between age and laryngoscopy grade III or IV but there was significant (P < 0.01) relationship with weight and external laryngeal manipulation. The advantage of the above tests lies in, incorporating them into the preoperative protocol, rather than using them as sole predictors of difficult laryngoscopy and intubation.

Adolescent↗

Opioid sparing during endotracheal intubation using McCoy laryngoscope in neurosurgical patients: the comparison of haemodynamic changes with Macintosh blade in a randomized trial.

BACKGROUND: There is conflicting data in literature to show that the McCoy laryngoscope is less stressful and opioids can actually be avoided during laryngoscopy and intubation with the use of this laryngoscope. AIM: A comparison of hemodynamic changes with McCoy vs Macintosh laryngoscope.. SETTINGS AND DESIGN: 180 ASA I and II neurosurgical patients undergoing elective surgery for space occupying lesions were recruited. The study was was prospective, randomized and blinded in the setting of neurosurgical perioperative services. METHODS AND MATERIALS: The patients were divided into four groups (Gr.1 McCoy and fentanyl; Gr. 2 McCoy and no fentanyl; Gr. 3 Macintosh and fentanyl; Gr. 4 Macintosh and no fentanyl). In Gr. 2 and 4 equivalent volume of saline was given in place of fentanyl as placebo. Heart rate, systolic and diastolic blood pressure were measured after laryngoscopy, after intubation and subsequently every minute for the next five minutes. The incidence of cough due to fentanyl treatment was observed. STATISTICAL ANALYSIS: Haemodynamic changes were compared between and within groups using oneway ANOVA and repeated measures ANOVA. All analysis included 95% CI at 5% significance. The Mann Whitney U test was used for comparing incidence of cough. RESULTS: No difference was found between McCoy laryngoscopy when done with or without fentanyl pretreatment (HR p=0.848, sys BP p=0.229 and diastolic blood pressure p=0.981). Significant changes in haemodynamic parameters were seen between Macintosh and McCoy laryngoscopy without fentanyl pretreatment (p<0.001) whereas changes were blunted with fentanyl pretreatment in Macintosh laryngoscopy (p<0.05). CONCLUSIONS: McCoy laryngoscope blade is less stressful and fentanyl pretreatment is not necessary to attenuate haemodynamic responses with its use in ASA I and II patients.

Adult↗

Haemodynamic effects of ketamine and thiopentone during anaesthetic induction for caesarean section.

Ketamine (1 mg . kg-1) or thiopentone (4 mg . kg-1) was used to induce anaesthesia for Caesarean section in 62 normotensive patients. During induction of anaesthesia and before laryngoscopy, blood pressure did not change in either group (preinduction systolic blood pressure, 131 mmHg, and diastolic blood pressure, 75 mmHg). When laryngoscopy and intubation were performed, mean blood pressures of both patient groups increased 20-30 per cent. With ketamine (n = 30) heart rate was unchanged from the preinduction rate of 85 beats/min before laryngoscopy and increased significantly by 15 per cent during laryngoscopy and intubation. With thiopentone (n = 32), heart rate increased significantly to 20 per cent above the preinduction rate of 87 beats/min during induction and increased further (to 35 per cent above the preinduction rate) during laryngoscopy and intubation. The average maximal rate-pressure product calculated for the thiopentone group was over 18,000, which was significantly higher than the 15,000 calculated for the ketamine group. Neonatal outcome as assessed by Apgar score and umbilical blood gas analysis was good and did not differ significantly between groups.

Blood Pressure↗

Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope.

The question of which is the optimum technique to intubate the trachea in a patient who may have a cervical(C)-spine injury remains unresolved. We compared, using fluoroscopic video, C-spine motion during intubation for Macintosh 3 blade, GlideScope, and Intubating Lighted Stylet, popularly known as the Lightwand or Trachlight. Thirty-six healthy patients were randomized to participate in a crossover trial of either Lightwand or GlideScope to Macintosh laryngoscopy, with in-line stabilization. C-spine motion was examined at the Occiput-C1 junction, C1-2 junction, C2-5 motion segment, and C5-thoracic motion segment during manual ventilation via bag-mask, laryngoscopy, and intubation. Time to intubate was also measured. C-spine motion during bag-mask ventilation was 82% less at the four motion segments studied than during Macintosh laryngoscopy (P < 0.001). C-spine motion using the Lightwand was less than during Macintosh laryngoscopy, averaging 57% less at the four motion segments studied (P < 0.03). There was no significant difference in time to intubate between the Lightwand and the Macintosh blade. C-spine motion was reduced 50% at the C2-5 segment using the GlideScope (P < 0.04) but unchanged at the other segments. Laryngoscopy with GlideScope took 62% longer than with the Macintosh blade (P < 0.01). Thus, the Lightwand (Intubating Lighted Stylet) is associated with reduced C-spine movement during endotracheal intubation compared with the Macintosh laryngoscope.

Adolescent↗

[Cardiovascular response to tracheal intubation in patients with intracranial tumor. Comparative study between urapidil and lidocaine].

OBJECTIVES: To compare the effects of urapidil and lidocaine on cardiovascular response to laryngoscopy and tracheal intubation in patients with brain tumors. PATIENTS AND METHODS: Prospective, randomized double-blind study of 40 ASA II-III patients undergoing elective surgery for supratentorial tumor resection. The patients were assigned to two groups of 20 to receive an intravenous bolus of 1.5 mg/kg of lidocaine or 0.4 mg/kg urapidil before laryngoscopy and intubation. Anesthetic induction was performed with 0.03 mg/kg midazolam, 3 micrograms/kg of fentanyl, 5 mg/kg of thiopental and 0.2 mg/kg of vecuronium. Anesthesia was maintained with N2O/O2 (60%/40%) and isoflurane (0.5% expired). The following variables were recorded: mean blood pressure, heart rate and arterial oxygen saturation (SpO2) at baseline and 1, 2 and 3 min after induction and at 1, 2, 3, 4, 5 and 10 min after laryngoscopy and tracheal intubation. RESULTS: The two groups were comparable with respect to age, sex, weight, height and baseline hemodynamics. No statistically significant differences in hemodynamic variables were found between the two groups. Mean blood pressure in the postintubation period stayed near baseline and heart rate increased significantly after laryngoscopy and tracheal intubation in both groups. SpO2 decreased 7 min after administration of urapidil and stayed lower throughout the study period and was statistically different from SpO2 in the lidocaine group. All changes described were within clinically normal ranges. CONCLUSIONS: In patients undergoing neurosurgery to remove a supratentorial tumor, both lidocaine and urapidil reduce the pressor response to laryngoscopy and tracheal intubation at the doses given in this study. However, neither was able to prevent the increase in heart rate.

Adult↗

[A comparison of bullard laryngoscope and intubating laryngeal mask using fiberoptic guidance for tracheal intubation].

The purpose of this study is to compare the success rate of tracheal intubation, intubation time and laryngoscopic view of the larynx by Bullard laryngoscope or by intubating laryngeal mask using fiberoptic guidance in 50 patients. Following a standardized induction protocol, conventional laryngoscopic view by Macintosh's laryngoscope was obtained and classified by Cormack's grades. We measured the times from incertion of laryngoscopy or laryngeal mask until obtaining the best view of the larynx and until tracheal intubation. A best view by Bullard laryngoscopy or by fiberoscopy through the laryngeal mask was classified by Cormack's grades. The success rate of tracheal intubation was higher by Bullard laryngoscopy than by intubating laryngeal mask. The durations of laryngoscopy and tracheal intubation were significantly shorter and Cormack's grades were significantly lower by Bullard laryngoscopy than by laryngeal mask and fiberscopy. These results demonstrate that tracheal intubation by Bullard laryngoscope is faster and more successful compared with intubating laryngeal mask using fiberoptic guidance.

Adolescent↗

[Comparison of 4 anesthesia induction protocols on hemodynamic changes in tracheal intubation].

This study was undertaken to determine whether alfentanil (A) or sufentanil (S) associated with propofol (P) or etomidate (E) can abolish or attenuate the hemodynamic response to laryngoscopy and orotracheal intubation in ASA I or II patients, during induction of anesthesia for lumbar spinal surgery. Eighty patients were randomly divided into four groups. Group I (AE) received alfentanil 30 micrograms/kg and etomidate 0.3 mg/kg; group II (AP) received alfentanil 30 micrograms/kg and propofol 1.5 mg/kg; group III (SE) received sufentanil 0.3 microgram/kg and etomidate 0.3 mg/kg; group IV (SP) received sufentanil 0.3 microgram/kg and propofol 1.5 mg/kg. In each group, narcotic and hypnotic were given respectively five minutes and three minutes before laryngoscopy. The intubation was facilitated by vecuronium 0.1 mg/kg. The sequence of laryngoscopy and orotracheal intubation was always performed in less than 20 seconds. The anesthesia was maintained by O2/N2O in IPPV (TV = 10 ml/kg; respiratory rate 12). Heart rate, systolic, diastolic and mean blood pressure were recorded at the following times: on arrival in the operating room (T-5), 3 minutes before laryngoscopy (T-3), just at laryngoscopy (T0) and 1 (T1), 3 (T3), 54 (T5) minutes after intubation. The comparison of baseline values (T-5) with T1 values showed that the heart rate did not change significantly in any group. Systolic blood pressure increased (p < 0.05) in SE group, decreased (p < 0.05) in AE and SE groups and did not change in AP and SP groups. Mean blood pressure increased in AE and SE groups, decreased in AP group but did not change significantly in SP group.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Results of esophageal biopsies performed during triple endoscopy in the pediatric patient.

BACKGROUND: Endoscopic examination (direct laryngoscopy and bronchoscopy) is the method of choice for diagnosis of respiratory symptoms of unknown cause in children. However, gastroesophageal reflux is being recognized increasingly often as a cause of pediatric respiratory symptoms and is difficult to diagnose on the basis of findings from direct laryngoscopy and bronchoscopy. In cases in which gastroesophageal reflux was included in the differential diagnosis, we additionally performed esophagoscopy with esophageal mucosal biopsies. OBJECTIVES: To determine the feasibility, safety, and efficacy of routinely performing esophageal biopsies during triple endoscopy in children. METHODS: Twenty-four children ranging in age from 2 weeks to 10 years were referred for airway evaluation. Under general anesthesia, children underwent direct laryngoscopy and bronchoscopy and esophagoscopy with mucosal biopsy. RESULTS: Esophageal mucosa biopsy specimens were quickly and safely obtained during endoscopic evaluation. There were no complications. Reflux esophagitis was present in 54% of biopsy specimens, as suggested by basal cell hyperplasia, papillary elongation, and/or inflammatory cell infiltrates. CONCLUSION: Gastroesophageal reflux is often difficult to diagnose in the pediatric population. When direct laryngoscopy and bronchoscopy is performed during examination of the child with airway symptoms, the addition of esophagoscopy with mucosal biopsies will safely and quickly provide data regarding the potential contribution of gastroesophageal reflux.

Biopsy↗

The role of airway fluoroscopy in the evaluation of stridor in children.

OBJECTIVE: To determine the role of airway fluoroscopy in comparison with other diagnostic modalities in diagnosing the site of partial airway obstruction in children with stridor. DESIGN: Prospective study comparing direct laryngoscopy and bronchoscopy with nasopharyngoscopy, airway fluoroscopy, and plain films. Children with stridor or partial airway obstruction were evaluated by the Department of Otolaryngology at Columbus Children's Hospital, Columbus, Ohio. A history review and physical examination, including flexible fiberoptic laryngoscopy, plain films, airway fluoroscopy, and direct laryngoscopy and bronchoscopy, were performed for all children. SETTING: Tertiary care children's hospital. PATIENTS: From November 1996 to September 1999, 64 children aged 1 week to 12 years, with a mean age of 1.8 years and male-female ratio of 3:2, were evaluated for stridor. MAIN OUTCOME MEASURES: The sensitivity and specificity of airway fluoroscopy in diagnosing the site of partial airway obstruction in comparison with nasopharyngoscopy and plain films. RESULTS: Airway fluoroscopy had a sensitivity of 80% for subglottic, 73% for tracheal, and 80% for bronchial sites of obstruction. It was less sensitive for supraglottic and glottic sites-33% and 14%, respectively. Nasopharyngoscopy was more sensitive for supraglottic and glottic sites of obstruction. Overall, airway fluoroscopy was far more sensitive than plain films for diagnosing site of obstruction. CONCLUSIONS: Airway fluoroscopy is a quick, noninvasive, and dynamic study of the entire airway that provides important additional information to the history review and physical examination and is a valuable adjunct to flexible fiberoptic laryngoscopy. It was far superior to plain films and may serve as a cost-effective screening tool in the evaluation of stridor in children, especially for lesions of the lower airway.

Airway Obstruction↗

Analysis of mathematical model for osseous factors in difficult intubation.

A two-dimensional model of the factors relevant to difficult laryngoscopy was analysed mathematically to determine clinical implications and limitations. The model describes the space into which the "inevitable residual volume" of the tongue (that part remaining anterior to the blade at laryngoscopy) can be displaced to permit a view of the larynx. Four points are used: the tip of the upper incisors; a point on the anterior airway just above the larynx; the mid-point between the mandibular condyles and the internal mid-point of the symphysis. The number, F, was defined by a formula developed from their spacial relationships. Decreasing F values imply an increasing likelihood of difficult laryngoscopy. The analysis investigated the effects of: translation of individual points; plotting individual point positions for specified F-values; translating adjacent pairs of points; treating any three points as a triangle which rotates about each of its apices; and lastly, translating three points independently. During manipulations the model behaved well mathematically. Single point analysis implied that jaw recession and a non-protruding mandible were comparable in effect. Closing the mouth around the laryngoscope blade maximised F-values. Prominence of the maxilla required greater forward displacement than backward movement of the symphysis for equivalent F-value change. One particular triangular rotation suggested an entirely novel mechanism for difficulty (the "hi-slung mandible") where the condyles are positioned more rostral than normal. An otherwise normal jaw with this configuration recedes markedly on opening. Further studies are required to validate the model. Accurate quantification of individual factors in difficult laryngoscopy may then be feasible.

Adult↗

Comparison of a rigid laryngoscope with the ultrathin fibreoptic laryngoscope for tracheal intubation in infants.

The flexible ultrathin fibreoptic laryngoscope allows placement of endotracheal tubes as small as 2.5 mm internal diameter. The purpose of this study was to document the safety and efficacy of intubation using an ultrathin fibreoptic laryngoscope. Proved safety and efficacy would justify the routine use of fibreoptic laryngoscopy in normal infants to maintain skills needed for management of the difficult infant airway. In this prospective study, 40 infants < 24 mo of age scheduled for elective surgery were randomly divided into two equal groups. After inhalation induction of anaesthesia, in 20 infants the trachea was intubated using direct rigid laryngoscopy, and in 20 using the ultrathin fibreoptic laryngoscope (size 1.8 mm OD) Olympus LFP. Time to successful intubation was recorded, as well as blood pressure, heart rate, end-tidal CO2 and oxygen saturation. Airway trauma in the operating room, the post-anaesthesia care unit, and on the first postoperative day was recorded. The intubation times using rigid laryngoscopy were less than those using fibreoptic laryngoscopy (13.6 +/- 0.9 sec (mean +/- SEM) vs 22.8 +/- 1.7 sec; P < 0.01). Oxygen saturation and end-tidal CO2 readings were not different between the two groups. After intubation, blood pressure and heart rate increased equally in both groups, returning to normal within one to two minutes. There was no difference in the airway trauma between groups. We conclude that the ultrathin fibreoptic laryngoscope is a safe and effective method for tracheal intubation in infants and may be used routinely in order to maintain fibreoptic airway skills.

Anesthesia, Inhalation↗

Use of a new videolaryngoscope (GlideScope) in the management of a difficult airway.

PURPOSE: To describe the clinical use of a new videolaryngoscope in a patient who had repeatedly been difficult or impossible to intubate by conventional direct laryngoscopy. This device provided excellent glottic visualization and permitted easy endotracheal intubation. CLINICAL FEATURES: A 74-yr-old male presenting for repeat elective surgery had a history of failed intubations by direct laryngoscopy and pulmonary aspiration with a laryngeal mask airway. He refused awake flexible fibreoptic intubation. After the induction of general anesthesia, laryngoscopy was performed using a GlideScope. This provided complete glottic exposure and easy endotracheal intubation. CONCLUSION: This new videolaryngoscope provided excellent laryngeal exposure in a patient whom multiple experienced anesthesiologists had repeatedly found to be difficult or impossible to intubate using direct laryngoscopy. The clinical role of this device awaits confirmation in a large series of difficult airways.

Humans↗

Video-intuboscopic monitoring of tracheal intubation in pediatric patients.

PURPOSE: To evaluate the efficacy of video-intuboscopic monitoring during orotracheal intubation in a pediatric anesthesia teaching unit. METHODS: In 100 pediatric patients direct laryngoscopy performed by residents or nurse anesthetists was monitored on a video display using a flexible, ultralight video-endoscopic system (O.D. 2.8 mm/length 1.8 m) within the endotracheal tube (ETT). Best direct laryngoscopic view was assessed by the intubator. The instructor observed the intubation procedure on the video display and noted number of intubation attempts, best laryngoscopic monitor view, tube passage through the larynx and final tube position. If required he gave instructions or corrections. After removal of the laryngoscope, tracheal tube position was adjusted using the monitor view. Difficulties attributed to the fibreoptic endoscope during intubation and removal from the ETT were recorded. RESULTS: The trachea was successfully intubated at the first attempt in all patients. The supervisor detected one esophageal and 12 endobronchial intubations that were immediately corrected before starting ventilation. Final visualized endotracheal tube adjustment above the carina was possible in all patients except in one with copious tracheal secretions. Compared with direct laryngoscopy the video display provided an improved view of the vocal cords during intubation. In six patients direct laryngoscopy was difficult but the tracheas were intubated using the monitor view. No difficulties with the equipment were encountered except that the black coated endoscope compromised recognition of the black ETT depth-markings in small tubes. CONCLUSIONS: Video-intuboscopic monitoring is a useful monitor of tracheal intubation. "The improved view of the cords may provide assistance during difficult laryngoscopy.

Adolescent↗

Limitations of difficult airway prediction in patients intubated in the emergency department.

STUDY OBJECTIVE: Physiognomic assessment of difficult laryngoscopy before rapid sequence intubation has been advocated for all emergency department (ED) intubations. The study objectives were to evaluate whether Mallampati scores, thyromental distance, and neck mobility could have been assessed in non-cardiac arrest ED-intubated patients and determine whether such tests would have been feasible in our rapid sequence intubation-associated laryngoscopy failures. METHODS: We retrospectively reviewed 37 months of ED intubations using prospectively collected data from electronic medical records, critical care flow sheets, and a trauma registry. All non-cardiac arrest ED-intubated patients were included for analysis. Mallampati scoring was deemed unobtainable if patients could not follow simple commands. Neck mobility and thyromental measurement were deemed unobtainable with cervical spine precautions. RESULTS: Eight hundred fifty intubations met the inclusion criteria, and 838 patients underwent rapid sequence intubation. Laryngoscopy failed in 3 patients who underwent rapid sequence intubation. Eight patients had awake nasal intubation, and 4 oral intubations were done without rapid sequence intubation. Four hundred fifty-two (53%) patients could not follow simple commands, and cervical spine immobilization was present in 370 (44%) patients. Only 32% of patients could follow simple commands and were not cervical spine immobilized. Among the 3 rapid sequence intubation laryngoscopy failures, no patients were following commands. CONCLUSION: Mallampati scoring, neck mobility testing, and measurement of thyromental distance could have been done in only one third of our non-cardiac arrest ED intubations and in none of the rapid sequence intubation failures. The inability to widely obtain these assessment tools, coupled with the low incidence of failed rapid sequence intubation, indicates limitations to using these screening tests in the ED setting.

Algorithms↗

The usefulness of the modified laryngoscopic blade for training novice laryngoscopists.

STUDY OBJECTIVE: The objective of this study was to evaluate the effectiveness of a modified Macintosh blade for reducing the chances of directly contacting the teeth and providing a satisfactory laryngoscopic view during laryngoscopies by novice laryngoscopists. DESIGN: This is a prospective clinical comparison study. SETTING: The study took place at an operating room of a university hospital. PATIENTS: Seventy-two patients with American Society of Anesthesiologists physical statuses I and II, aged 16 to 64 years, who were scheduled for elective surgery requiring general anesthesia with endotracheal tube placement participated in this study. INTERVENTIONS: Laryngoscopy was performed twice on each patient, once with a regular Macintosh no. 3 blade and once with a blade in which the flange was partially removed. MEASUREMENTS: As an indirect parameter for anticipating potential dental injury during laryngoscopy, the perpendicular distance from the tip of the maxillary central incisor to the flange of each blade (the blade-tooth distance) was measured when a novice laryngoscopist lifted up the laryngoscope and visualized the glottis. We compared the blade-tooth distances, the chances of directly contacting the tooth, laryngoscopic views, and the subjective feeling of difficulty in handling the laryngoscope between the 2 blades. MAIN RESULTS: Blade-tooth distance varied significantly between the 2 blades: the median/interquartile range was 1.2/2.3 mm vs 3.0/4.3 mm for the regular Macintosh no. 3 and the modified blade, respectively (P<.01). The modified blade was associated with decreased chances of directly contacting the teeth (P<.05). In addition, the modified blade provided a better laryngoscopic view than did the regular blade (P<.01). Most novice laryngoscopists felt that laryngoscopy with the modified blade was significantly easier than that with the regular Macintosh blade (P<.01). CONCLUSIONS: The modified Macintosh blade used in this study proved to be a useful device for training novice laryngoscopists with respect to procedure effectiveness and patient safety.

Adolescent↗