Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Knee Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

Composites for bone replacement.

The application of synthetic materials for bone replacement is now well established, but it is recognized that mechanical compatibility, as well as biocompatibility, of the tissue and implant is required if stress shielding and consequent bone resorption is to be avoided at areas of fixation. The development of materials analogous to the natural tissue for longer term implantation is discussed, with particular reference to hydroxyapatite reinforced polymers.

Biocompatible Materials↗

A wheelchair cushion designed to redistribute sites of sitting pressure.

OBJECTIVES: Despite the diversity of wheelchair cushions currently in clinical use, pressure on bony prominences continues to be a major problem for wheelchair-bound patients, and the incidence of pressure ulcers remains high. No static surface has been reported to reduce resting pressure under the ischial tuberosities to below that of capillary pressure, which may well be the threshold for inducing tissue damage. An entirely new form of seating was designed to decrease absolute pressure using a prosthetic fitting technique analogous to a below-the-knee prosthesis. DESIGN: A repeated measures randomized design was used to test differences between the experimental (TCS) and three other standard cushions. SETTING: A Veterans Medical Center outpatient service. PATIENTS: Wheelchair-bound volunteer subjects, n = 47, were selected who weighed more than 60kg. MAIN OUTCOME MEASURES: Pressures were measured by a standard air pressure pad and also by a computer-linked array of pressure transducers. The grid was standardized and used to generate topographic maps for each site over time. These data were used to measure the seating interface pressures. RESULTS: There was a significant main effect of cushion over site, F = 131 for left ischial tuberosity. Pressure were lowest while patients sat on the experimental seat and differences were significant at all time points. Using 1psi as presumed capillary pressure, frequency of success at achieving this pressure threshold was greatest for the experimental seat, p < .001. This difference persisted throughout the 30 minutes of testing. CONCLUSIONS: A computerized pressure grid was developed that allowed evaluation of anatomically localized pressures. The prosthetically designed TCS displays lower seating pressures than any other cushion tested. Consistent and sustained pressures were below the postulated threshold for tissue damage.

Adult↗

Metallic artefacts in MR imaging: effects of main field orientation and strength.

AIM: To determine the effect of metallic implant positioning on magnetic resonance (MR) imaging artefacts, and to determine the optimal imaging parameters for minimization of metallic artefacts. MATERIALS AND METHODS: In a phantom and in three joints with non-ferromagnetic metallic implants imaged at 1.5 and/or at 0.2 T, we examined the influence of the static magnetic field (B(0)) strength and orientation, frequency-encoding direction, and type of imaging sequence on metallic artefacts. RESULTS: The impact of artefacts caused by metallic objects depends mainly on the relationship between the anatomy of interest and the orientation of the object relative to the direction of B(0). The main field strength plays a less important role, but its orientation depends on the type of MR imager. CONCLUSION: MR artefacts can be easily minimized by optimally positioning patients with metallic implants in the magnet. Knowledge of how this influences MR imaging is helpful in patient selection and guiding limb positioning.

Artifacts↗

Scintigraphic evaluation of the painful prosthetic joint: a comparison of gallium-67 citrate and indium-111 labelled leucocyte imaging.

The radiopharmaceuticals gallium-67 and indium-111 labelled leucocytes have been compared in 15 patients with a painful joint prosthesis in an attempt to identify those patients with periprosthetic infection. Gallium-67 images were abnormal in five out of six patients with periprosthetic infection and normal in seven out of nine without evidence of infection. Indium-111 leucocyte images were abnormal in three out of six patients with infection and normal in all nine patients without infection. Indium-111 labelled leucocyte imaging is technically more difficult to perform than gallium-67 imaging. This, combined with the higher sensitivity of gallium-67 imaging for infection around a prosthetic joint, leads us to conclude that gallium-67 imaging is superior to indium-111 leucocyte imaging in identifying infection as a cause of a painful prosthetic joint.

Adult↗

[Recurrent spontaneous pneumothorax complicating osteosarcoma pulmonary metastasis].

We report the case of a 15-year-old girl with osteosarcoma in the left distal femur who developed a recurrent spontaneous pneumothorax. The patient was treated by neoadjuvant chemotherapy followed by surgery (limb-sparing surgical procedure with insertion of a knee prosthesis) and then adjuvant chemotherapy. The initial extension assessment was normal. No pulmonary metastasis was found. The chest tomography performed at the end of treatment (8 months after surgery) revealed two peripheral pulmonary nodules not seen on the chest X-ray. Palliative chemotherapy was given, the thoracic tomography after four chemotherapy courses showed a progress of the pulmonary metastasis and on the right more abundant bilateral pneumothorax which had recurred two months after thoracic draining. Thoracoscopy showed no pleural lesions.

Adolescent↗

[Mathematical kinematic methods in joint prosthetics].

By the use of mathematical and cinematical methods a new understanding for the construction as well as for the implantation-techniques for endoprosthesis can be developed. With these methods the size of the natural motion and the process of the natural motion can be studied. So we get better informations about the natural motion and we can deduce criterions for the construction of endoprosthesis, for we can compare the motion of a model with the natural way of motion. So we can estimate preoperative the efficiency and the maximal load of the prosthesis as a result of incorrect motions. Such incorrect motions can be caused or can be avoid by the construction of the endoprosthesis as well as the implantation techniques.

Biomechanical Phenomena↗

[Electron spectroscopy for chemical analysis. (ESCA). Examinations on formation and re-formation of the passive layer on vitallium (author's transl)].

The passive layer of a metal implant is responsible for its tolerance in a biological environment. A report is given on ESCA-investigations on the passive layer on Vitallium implants which consists largely of Cr-oxide and is only approx. 3-5 micrometer thick. This passive layer can easily be damaged with OP-instruments. The oxide layers rebuilt on exposure to air or on sterilization in boiling water were also investigated by ESCA. Oxide layers normally formed are very similar to the original passive layer. Accumulations of Co- and Mo-oxides are also observed, however. Some short implantation experiments show that the thin Cr-oxide layer is indeed effective as a passive layer. The analytical findings indicate that the formation or re-formation of the passive layer is due to a selective dissolution process. This accords with results obtained by the neutron activation analysis of the serum.

Chromium Alloys↗

[Antibiotic prophylaxis of postoperative infection in orthopedics. Results of an epidemiologic survey in Italy conducted by the Journal of Chemotherapy].

An epidemiological survey of the use of antimicrobial prophylaxis in Italian hospitals was carried out under the auspices of the Journal of Chemotherapy. Out of 500 Italian orthopedic centers requested, 225 have participated in this study. A total of 136,321 surgical procedures were reported in the 166 centers reporting complete answers on type of surgery. They comprised hip and knee prosthesis (13.9%), spine surgery (4%), hip endoprosthesis (5.2%), osteosynthesis (26.9%), arthroscopy (24.4%), and others (25.5%). Perioperative antimicrobial prophylaxis was used in 75% of operations (ranging from 57.1% to 99.4% in arthroscopy and joint prosthesis, respectively). Short term (< 24 h) antimicrobial prophylaxis was performed in 38.4% of the 206 Centers answering this question correctly. 61.1% of Centers employed single agent prophylaxis. 70.8% of these prescriptions were betalactam antibiotics. Bacteriological analysis of the wound in 86 Centers (total number of isolates 2013) revealed the presence of Gram-positive isolates in 73.7% of cases. Methicillin resistance was expressed in 45% of 915 tested strains. Out of 4221 patients with high risk of infectious complications (joint prosthesis surgery) given antimicrobial prophylaxis in 46 Centers, the percentage of surgical wound infections was overall 2.1%, while that of non-surgical wound infections was 3.6%. A decrease in the total infection rate by about half was associated with long-term (> 24 h) as compared to short-term (< 24 h) antibiotic treatment (3.7 vs 7.6%, respectively), and with the use of antibiotic drug combinations vs single antibiotic drugs (3.9 vs 6.6%, respectively). The incidence of surgical-site infection is not decreased by extending the chemoprophylaxis for more than the first 24 h after surgery, while it is reduced from 2.5 to 1.4% by use of combination antibiotic therapy.

Antibiotic Prophylaxis↗

Impact of postdischarge surveillance on surgical site infection rates for several surgical procedures: results from the nosocomial surveillance network in The Netherlands.

OBJECTIVE: To compare the number of surgical site infections (SSIs) registered after hospital discharge with respect to various surgical procedures and to identify the procedures for which postdischarge surveillance (PDS) is most important. DESIGN: Prospective SSI surveillance with voluntary PDS. Recommended methods for PDS in the Dutch national nosocomial surveillance network are addition of a special registration card to the outpatient medical record, on which the surgeon notes clinical symptoms and whether a patient developed an SSI according to the definitions; an alternative method is examination of the outpatient medical record. SETTING: Hospitals participating in the Dutch national nosocomial surveillance network between 1996 and 2004. RESULTS: We collected data on 131,798 surgical procedures performed in 64 of the 98 Dutch hospitals. PDS was performed according to one of the recommended methods for 31,134 operations (24%) and according to another active method for 32,589 operations (25%), and passive PDS was performed for 68,075 operations (52%). Relatively more SSIs were recorded after discharge for cases in which PDS was performed according to a recommended method (43%), compared with cases in which another active PDS method was used (30%) and cases in which passive PDS was used (25%). The highest rate of SSI after discharge was found for appendectomy (79% of operations), followed by knee prosthesis surgery (64%), mastectomy (61%), femoropopliteal or femorotibial bypass (53%), and abdominal hysterectomy (53%). CONCLUSIONS: For certain surgical procedures, most SSIs develop after discharge. SSI rates will be underestimated if no PDS is performed. We believe we have found a feasible and sensitive method for PDS that, if patients routinely return to the hospital for a postdischarge follow-up visit, might be suitable for use internationally.

Community Networks↗

Fungal prosthetic arthritis: presentation of two cases and review of the literature.

Fungal infections complicating reconstructive arthroplasty are extremely rare, with only six previously reported cases. These infections follow an indolent course and involve pain without inflammation in the affected joint, often as late as 2 years after surgery. Candida species other than Candida albicans are the commonest fungal pathogens and represent intraoperative contaminants. The diagnosis is made difficult by the indolent course and the frequent interpretation of the fungal isolate as a culture contaminant. Therapy requires resection of the prosthetic components with debridement; the additional need for antifungal therapy remains unclear.

Aged↗

Periprosthetic candidal infections following arthroplasty.

Candidal infection after prosthetic arthroplasty has been reported in six previous cases, to which four cases are now added. Candida albicans was the offending organism in four patients, Candida parapsilosis in three, Candida tropicalis in two, and Candida (Torulopsis) glabrata in one. None of the 10 patients had evidence of disseminated candidiasis, and, except for the uniform presence of a prosthesis, other underlying factors that are generally associated with candidal infections were present in only three. Clinical features that distinguished periprosthetic from natural bone and joint infection included an older patient population, the usual lack of predisposing factors other than the prosthesis, and the absence of evidence of disseminated candidiasis. All patients were treated with removal of the prosthesis and antifungal therapy, consisting of amphotericin B alone (six patients) or combined with 5-fluorocytosine (three patients) or ketoconazole (one patient). Infection appeared to be cured in nine of the 10 patients, but the follow-up was less than 1 year in five cases. Replacement with a new prosthetic joint was attempted in only two cases and successful in only one. Direct inoculation of organisms during surgery or transient unrecognized candidemia may initiate periprosthetic infection, which might then be promoted by favorable local factors, both mechanical and molecular. The role of prosthetic materials, candidal adhesins, and human factors such as fibronectin in initiating these infections has yet to be characterized.

Adult↗

Experimental models in the investigation of device-related infections.

There has been an increasing concern with the problem of device-related infections, ever since foreign materials such as metal or plastic began to be used in implant surgery. The prophylaxis and treatment of such infections is difficult to evaluate in clinical studies, because placebo-controlled prophylaxis trials are thought to be unethical, and no single centre has enough patients for comparative treatment studies. For this reason different experimental models have been developed to study aspects of device-related infections. In this review, these infection models are presented. Different applications of the tissue-cage guinea pig model are summarized. This model allows the study of pathogenesis, natural course, prophylaxis, and treatment of device-related infection. In addition, by using this infection model, novel microbiological in-vitro tests could be developed, and questions of biocompatibility analysed.

Animals↗

Functional lower limb salvage with an osteocutaneous filet flap of the foot.

An osteocutaneous foot filet flap based on the posterior tibial vessels was successfully used to provide tibial coverage in a patient requiring a below-knee amputation following a high-voltage electrical injury. Addition of the calcaneus to the standard foot filet flap provided a vascularized bone graft that served to both lengthen the tibia and secure the flap via a tibial-calcaneal synostosis. The synostosis provided firm anchoring of the flap and allowed for a partial end-bearing, below-knee prosthesis.

Aged↗

Infected arthroplasties.

Infection is potentially the most serious complication of total joint arthroplasty. Over the last 10 years, considerable advances have been made in the diagnosis and management of the infected implant. Modern methods of treatment are successful in up to 90% of cases in the lower limb, and results appear to be improving in the upper limb. This review places recent advances in the context of previous published work in the field.

Elbow Joint↗