Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Ejection fraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

Comparative study of three automatic programs of left ventricular ejection fraction evaluation.

The aim of this study was to compare three automatic programs (P1, P2, P3) for evaluating radionuclide left ventricular ejection fraction (LVEF) and to emphasize the clinical consequences. Gated radionuclide ventriculography was performed in 73 subjects, 15 of whom were healthy and 58 of whom had experienced heart failure. All scintigraphic data were processed with the three programs. Good inter-observer, intra-observer and automatic-manual reproducibility were observed using each of the three programs. On the other hand, in the normal subjects, the three mean normal LVEF values were significantly different from each other (P1 = 77 +/- 5%, P2 = 63 +/- 7%, P3 = 68 +/- 8%; P < 0.0001) In the pathological patients, the values obtained with P2 were significantly different from those obtained using P1 and P3 (P1= 32 +/- 15%, P2 = 26 +/- 13%; P < 0.0001), Moreover, the linear regression studies between the three automatic programs were always significantly different from the identity line equation (y = x). This study shows that LVEF criteria for normality depend on the program used, and inter-program measurement of LVEF is poorly reproducible. Caution is recommended when comparing data obtained from different centres (or different computers), either in the follow-up of a given patient or in gathering results from patient groups.

Adult↗

Changes in ejection fraction during induction of anesthesia with two different i.v. techniques.

Two intravenous induction techniques were compared with respect to changes in ejection fraction (EF) and central hemodynamics in 30 patients scheduled for coronary artery surgery. Left ventricular EF was measured with a collimated single crystal probe linked to a microcomputer, after injection of 200 MBq Tc 99 m HSA. Stroke volume index (SI) determined by thermodilution and EF were used to calculate left ventricular volume in end-systole and end-diastole. In 20 patients (Group I), anesthesia was induced with diazepam (94 micrograms x kg-1), thiopentone (3 mg x kg-1) and fentanyl (3 micrograms x kg-1). In 10 patients (Group II), fentanyl (30 micrograms x kg-1) was used for induction. In Group I, EF decreased from 0.43 to 0.26 at intubation, while systemic vascular resistance index (SVRI) showed an increase. Left ventricular volume decreased during induction of anesthesia except during intubation. In Group II, EF and left ventricular volume remained unchanged during the study period. SVRI showed no increase at intubation. No change in contractility was indicated from the relation between the end-systolic pressure and volume, in any of the groups.

Anesthesia, Inhalation↗

Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs.

UNLABELLED: Gated myocardial perfusion SPECT has been used to calculate ejection fraction (EF) and end-diastolic volume (EDV) and has correlated well with conventional methods. However, the comparative accuracy of and correlations across various types of gated SPECT software are not well understood. METHODS: Mathematic phantoms of cylindric-hemispheric hybrid models, ranging in volume from 34 to 266 mL, were generated. The clinical cases consisted of 30 patients who participated in a radionuclide angiography and gated blood-pool (GBP) study in addition to undergoing (99m)Tc-sestamibi gated SPECT. Four kinds of software, Quantitative Gated SPECT (QGS), the Emory Cardiac Toolbox (ECT), 4D-MSPECT, and Perfusion and Functional Analysis for Gated SPECT (pFAST) were used to compute EF and EDV, and the results were analyzed by multiple comparisons tests. Patients were classified into 4 groups (i.e., no defect, small defect, large defect, and small heart) so that factors affecting variation could be analyzed. RESULTS: In mathematic models > or = 74 mL, volume error was within +/-15%, whereas for a small volume (34 mL), QGS and 4D-MSPECT underestimated the volume and pFAST overestimated it. The respective intra- and interobserver reproducibility of the results was good for QGS (r = 0.99 and 1.00), ECT (r = 0.98 and 0.98), and 4D-MSPECT (r = 0.98 and 0.98) and fair for pFAST (r = 0.88 and 0.85). The correlation coefficient for EF between gated SPECT and the GBP study was 0.82, 0.78, 0.69, and 0.84 for QGS, ECT, 4D-MSPECT, and pFAST, respectively. The correlation coefficient for EDV between gated SPECT and the GBP study was 0.88, 0.89, 0.85, and 0.90, respectively. Although good correlation was observed among the 4 software packages, QGS, ECT, and 4D-MSPECT overestimated EF in patients with small hearts, and pFAST overestimated the true volume in patients with large perfusion defects. Correlation coefficients among the 4 kinds of software were 0.80-0.95 for EF and 0.89-0.98 for EDV. CONCLUSION: All 4 software programs showed good correlation between EF or EDV and the GBP study. Good correlation was observed also between each pair of quantification methods. However, because each method has unique characteristics that depend on its specific algorithm and thus behaves differently in the various patient subgroups, the methods should not be used interchangeably.

Coronary Circulation↗

Myocardial revascularization for patients with an ejection fraction of 0.2 or less. 12 years' results.

From 1969 through December 31, 1981, a total of 232 patients with an ejection fraction of 0.2 or less (normal 0.67) had myocardial revascularization. The in-hospital mortality in these patients decreased from 25 deaths in 82 patients (30%) from 1969 through 1972 to 10 deaths in 150 patients (7%) from 1973 through December 31, 1981. There was a 24% five-year survival for patients in congestive heart failure at the time of operation, a 40% survival at five years for patients successfully treated for failure before operation and a 60% five-year survival for those patients who had never been in failure. These results would appear to be better than those with cardiac transplantation, with neither the restrictions for operation nor the long-term immunotherapy required with cardiac transplantation.

Adult↗

Disproportionate effects of regional hypokinesis on radionuclide ejection fraction: compensation using attenuation-corrected ventricular volumes.

This study evaluates the potential effects of regional hypokinesis on measurements of global ejection fraction (EF) as determined by radionuclide angiographic techniques. Studies were performed in a two-compartment left-ventricular (LV) model that allowed stimulation of global, anterior-region, or posterior-region hypokinesis in a torso chamber with heart-to-background activity similar to that in clinical studies. Radionuclide techniques accurately measured changes in EF during global hypokinesis but progressively underestimated true EF during increasing anterior-region hypokinesis, and progressively overestimated true EF during increasing posterior hypokinesis. When EF (y-axis) was plotted against true EF (x-axis) for a 240-ml model, from linear regression equations, the slopes and intercepts were significantly different for anterior and posterior hypokinesis. The disproportionate effects of regional hypokinesis increased with LV size. Accurate EF was computed during regional hypokinesis by determining absolute LV volumes from count rates corrected for attenuation, depth, background activity and blood-pool activity. Thus, the disproportionate effects of regional hypokinesis on EF were corrected by considering differential count attenuation.

Cardiac Output↗

[Coronary artery bypass grafting for a patient with left ventricular ejection fraction of 16%: a case report and review of the Japanese literature].

A 65-year-old man with left ventricular ejection fraction (LVEF) of 16% successfully underwent coronary artery bypass grafting (CABG). CABG used to be contraindicative for patients with LVEF below 20%. However, such patients are recently involved to indication of CABG if viability of the myocardium is proved. We consider CABG is indicated for a patient who keeps a sufficient cardiac output despite a low level of LVEF. Intraaortic balloon pumping which was started immediately after the induction of anesthesia was effective. Only eight patients with LVEF below 20% have undergone CABG in Japan. Thus, we reported our patient with some discussion on operative indication and perioperative management.

Aged↗

Demonstrating time sequence and extent of sustained decrease in native heart ejection fraction after heterotopic transplantation.

BACKGROUND: In this study we investigate the time sequence and extent of the sustained decrease in native heart ejection fraction (EF) after heterotopic heart transplantation (HHTx) when using gated cardiac blood pool scanning (GCBPS) and transthoracic echocardiography (TTE) One case report of 2 patients used post-operative GCBPS and TTE and found a significant deterioration in native heart EF post-operatively over the course of several years. Comparison with pre-operative measurements using these techniques in a series of patients has not been performed previously. METHODS: Thirteen of 16 HHTx patients with adequate pre- and post-operative GCBPS follow-up were included in this study. All patients also underwent TTE post-operatively and the GCBPS results were correlated with the TTE findings. RESULTS: GCBPS demonstrated a marked (21.1 +/- 4.7% vs 10.5 +/- 3.7%, p < 0.0001) decrease in native EF post-HHTx. Spontaneous echo contrast in the native left ventricle and/or poor opening of the mitral/aortic valves was noted at Day 1 in 4 of 5 patients who had a TTE at this stage. No further decline was noted between the first and last post-operative GCBPS (10.8 +/- 3% vs 8.6 +/- 2.1%, p = NS). CONCLUSIONS: A dramatic decrease in native heart EF post-HHTx occurs as early as Day 1 post-transplant. Dissociation of ventricular contraction is the most likely cause. Studies have demonstrated that paced linkage (counterpulsation) between the ventricles results in improved hemodynamics. This may have clinical implications as to the timing of ejection of blood from a left ventricular assist device (LVAD) and for providing the best hemodynamics for the ventricle being assisted and for optimizing its chances of long-term recovery.

Echocardiography↗

Reproducibility of determination of right ventricular ejection fraction by radionuclide imaging: assessment by the statistical method of variance components.

Confidence limits for single and repeat measurements of right ventricular ejection fraction (RVEF) were established by means of a model based on the statistical method of variance components. A total of 80 subjects (age 23 to 74 years) were examined by two radionuclide methods 1) gated first-pass (fp) technique performed in a standard 30 degrees right anterior oblique projection, and 2) multigated equilibrium imaging (muga) in an individual left anterior oblique view, applying with both methods separate end-diastolic and end-systolic ventricular regions of interest. Values obtained by fp technique were clearly higher than those measured by the muga approach, and the correlation between them was only fair: RVEFmuga = 0.48 RVEFfp + 0.13; r = 0.73; SEE = 0.08. The 95% confidence limits for a single measurement were with the fp technique: 'true' RVEF = measured RVEF +/- 6 EF-units compared to +/- 16 units with the muga method. At repeat determination within an interval of four weeks, the minimal changes in measured RVEF that were statistically significant at the 5% level were with the fp technique +/- 8 units with the same observer on both occasions and +/- 9 units with different observers. Corresponding figures with the muga method were +/- 16 and +/- 22 units, respectively. The minimal changes in a subject's 'true' RVEF necessary to produce a significant change in measured RVEF were with fp technique +/- 14 units for the same observer and +/- 17 units for different observers, compared to +/- 30 and +/- 41 units with the muga method. In conclusion, the variability with the muga approach was far greater than with the fp technique and the consequent reproducibility so poor as to preclude meaningful measurement of RVEF by the muga method.

Adult↗

Echocardiographic ejection fraction in patients with acute heart failure: correlations with hemodynamic, clinical, and neurohormonal measures and short-term outcome.

BACKGROUND: Although echocardiographic ejection fraction (EF) is frequently used for the estimation of left ventricular contractility in patients with acute heart failure, its exact role and correlations with clinical, hemodynamic, and neurohormonal variables of cardiac contractility is not known. METHODS: Patients (343) with acute heart failure, enrolled into two prospective placebo-controlled hemodynamic studies of tezosentan, and in whom EF was available at baseline, were included. Outcome was evaluated in a subset of 94 patients who were enrolled in the placebo arms of the studies. RESULTS: Higher echocardiographic EF was correlated with older age, increased incidence of hypertension and atrial fibrillation, and female gender. We observed weak correlation between EF and cardiac output or cardiac power and no correlation with wedge pressure, and the change in hemodynamic variables over time. Higher EF was correlated with more baseline leukocytosis and higher plasma levels of endothelin-1 and blood urea nitrogen, while lower EF was related to higher baseline B-type natriuretic peptide (BNP). We observed no overall correlations between EF and outcome. CONCLUSIONS: In patients with acute heart failure, echocardiographic EF is weakly correlated with hemodynamic measures of left ventricular contractility and outcome; hence, it should be interpreted cautiously when evaluating patients admitted due to acute heart failure.

Aged↗

Prescription of beta-blockers in patients with advanced heart failure and preserved left ventricular ejection fraction. Clinical implications and survival.

BACKGROUND: The effects of beta-blockers in patients with heart failure (HF) and preserved left ventricular ejection fraction (LVEF) are not well established. AIMS: To assess the association between beta-blocker prescription at discharge and mortality in a cohort of patients with advanced HF and preserved LVEF. METHODS AND RESULTS: We prospectively studied a cohort of 443 patients with advanced HF and preserved LVEF (LVEF> or =40%). Mean age was 78 years, 56% female, 33% NYHA class IV. Overall, 227 patients (51%) had a beta-blocker prescribed at discharge. Mean duration of follow-up was 25 (+/-18) months. Death (all cause) occurred in 40 patients (17.6%) who were receiving a beta-blocker at discharge and 73 patients (33.8%) who were not on a beta-blocker. In multivariate Cox analysis, including adjustment for propensity score, prescription of a beta-blocker remained associated with a 43% relative mortality risk reduction (HR 0.57, 95% CI 0.37 to 0.88, p=0.01). CONCLUSIONS: In this cohort of patients with advanced HF and preserved LVEF, prescription of a beta-blocker was associated with a significant mortality reduction. This beneficial effect of beta-blocker use needs to be further confirmed in prospective, randomised clinical trials.

Adrenergic beta-Antagonists↗

Postischemic stunning can affect left ventricular ejection fraction and regional wall motion on post-stress gated sestamibi tomograms.

OBJECTIVES: This study was designed to investigate whether left ventricular ejection fraction (LVEF) calculated from post-stress single-photon emission computed tomography (SPECT) reflects the basal value for LVEF or whether post-stress LVEF is reduced in some patients with stress-induced ischemia. BACKGROUND: Automated programs are now commercially available for assessing global left ventricular (LV) function from post-stress technetium-99m sestamibi gated SPECT performed >15 min after completion of exercise. METHODS: Eighty-one sequential patients who underwent a 2-day stress/rest sestamibi imaging protocol and showed perfusion defects on the post-stress tomogram underwent gated acquisition of the second-day rest tomogram. The post-stress and rest tomographic images were read for presence, location, severity and reversibility of defects by consensus of two to three experienced observers with the aid of circumferential count displays. Defects were scored as mild, moderate or severe and as completely or partially reversible or fixed, and a summed defect severity score was calculated. Of these 81 scans, 20 showed nonreversible perfusion defects (group 3), whereas 61 showed reversible perfusion defects. Post-stress and rest LVEF was calculated from the processed gated SPECT data. From 15 additional patients who underwent rest gated SPECT studies on separate days, serial reproducibility of LVEF values calculated from the gated SPECT data was determined to be +/-5.2%. Coronary angiography was performed within 3 months of the scan without intervening events in 47 of 81 patients, including 39 of 61 with reversible perfusion defects. RESULTS: In 22 (36%) of 61 patients with reversible perfusion defects, post-stress LVEF was >5% lower than that at rest (group 2), whereas in the remaining 39 patients, post-stress LVEF was either +/-5% or greater than that at rest (group 1). Segmental chordal shortening analysis performed in group 2 studies showed that differences in chordal shortening between rest and post-stress were significantly greater in the reversible perfusion defect territories than in the nonischemic perfusion defect territories ([mean +/- SD] 0.14 +/- 0.14 vs. 0.02 +/- 0.09, respectively, p < 0.0001). There were no significant differences among groups for any of the following variables: age, gender, previous myocardial infarction and type of stress. Time to imaging and stress and scan variables were correlated with the change in LVEF by univariate analysis, and the two variables that correlated significantly were the summed defect reversibility score on the scan and a left anterior descending coronary artery location of the scan defect. Only summed defect reversibility score was significant on multivariate analysis. CONCLUSIONS: When the only gated sestamibi scan is the post-stress scan, global and regional LV function will not represent basal LV function in all patients with stress-induced ischemia.

Dipyridamole↗

Ejection fraction: subjective visual echocardiographic estimation versus radionuclide angiography.

OBJECTIVES: The aim of this study was to validate the correlation of left ventricular ejection fraction (LVEF) between two-dimensional (2D) echocardiography with harmonic imaging modality and radionuclide angiography (RNA) in a large number of patients. BACKGROUND: Subjective visual estimation of LVEF is the most prevalent method in evaluating left ventricular systolic function. Previous published reports demonstrated that visual estimation from 2D was superior to other mathematical calculations, however the studies contained less than 50 patients. METHODS: Retrospective review of 377 consecutive medical records containing LVEF from both 2D echocardiography and RNA obtained from the same patient within 15 days from January 1998 to September 1999. RESULTS: Correlation coefficient value (r) between 2D echocardiography subjective visual estimation and RNA was 0.84. The r value was further increased to 0.87 when heart transplant recipients excluded. The agreement of LVEF between 2D echocardiography and RNA are higher in normal or severely depressed LV. CONCLUSION: Excellent correlation of LVEF exists between 2D echocardiography subjective visual estimation and RNA, especially in normal or severely depressed LV.

Echocardiography↗

[Results of employing single crystal gammacamera and minicomputer in the first tracer passage to determine left-ventricular ejection fraction and wall motion (author's transl)].

Single crystal gammacamera and minicomputer were employed in 71 patients to determine left-ventricular ejection fraction (EF) (17 mCi 99mTc-HSA; 30 degrees RAO projection) by means of the first tracer passage. In 30 out of these patients, ventricular wall motion could be analyzed additionally because later on the gammacamera was equipped with a converging collimator. Comparison with cineventriculographically determined EF values revealed a good correlation (r = 0.91), not depending on left-ventricular wall motion pattern. Hereby, with first transit, high EFs were computed somewhat lower and low EFs were found somewhat higher. This non-limiting discrepancy is closely related to the influence of paracardiac "background"-radioactivity. Comparative analysis of segmental wall motion demonstrated agreement in 83% of the 90 segments examined. Therefore, it can be confirmed that performance of the first tracer passage for a evaluating segmental wall motion must not mandatorily be done with a multicrystal camera.

Adult↗

A method of left ventricular ejection fraction estimation from cineangiocardiograms employing a special-purpose calculator.

A special-purpose calculator is described which computes the left ventricular ejection fraction and end-diastolic volume (and thus stroke and end-systolic volumes) from single-plane cineangiocardiograms. A pair of manual callipers is used to convert the length information of angiographic projections into digital form for processing by the calculator. Volumes are estimated by means of a first order numerical integration method assuming circular cross-section. The angiograms of 42 patients were analysed using both the calculator and a conventional method. The results of the 2 methods correlated very closely (r = 0.99) with a slope within 1% of unity. The calculator is suggested as a practical and cheaper alternative to computer-based systems.

Angiography↗

Value of partial ejection fraction, volume increment, and regional wall motion in identifying patients with clinically significant coronary artery disease.

Recent studies suggest that the partial ejection fraction (EF) in early systole is a more sensitive index of left ventricular (LV) dysfunction than the holosystolic EF. We examined LV volume, partial EF, and volume increment at each of 12 time points in systole to determine which parameter best distinguishes normal subjects from patients with coronary artery disease (CAD). Contrast ventriculograms, obtained either in the right anterior oblique projection (60 frames/sec) or in the biplane projection (30 frames/sec), of 58 normal subjects and 68 patients with CAD were studied. The endocardial contour in each frame of a sinus beat was traced to derive a volume curve. At each twelfth of systole, LV volume was extrapolated from the curve and the partial EF was calculated. The increment in volume between successive time points was also calculated. Both partial EF and LV volume in patients with CAD became progressively more abnormal with time; peak abnormality occurred at end-systole. In a subgroup of patients with CAD who had normal holosystolic EF, both partial EF and volume were normal throughout systole. The increment in volume with each twelfth of systole in patients with CAD deviated less than 1 SD from normal throughout systole. Thus, maximum abnormality in partial EF and volume occurs at end-systole. Of the parameters of global LV function tested, holosystolic EF best distinguishes patients with CAD from normal subjects. However, regional wall motion measured in the area of interest is more sensitive to localized abnormality, the severity of which may be overestimated or underestimated by the EF due to hyperkinesis or hypokinesis in other regions of the left ventricle.

Cardiac Catheterization↗

Adriamycin and epirubicin treatment monitored by radionuclide ejection fraction during therapy and follow-up.

Twenty-four patients with advanced breast cancer were studied with serial determinations of the radionuclide ejection fraction at rest (RST-LVEF) during anthracycline chemotherapy (CT) and with a mean follow-up (FU) of 8 months. We had 2 cases of anthracycline congestive heart failure (CHF) during FU, 3 and 12 months respectively after the end of CT. The RST-LVEF changes observed during CT were not able to predict which patients were to develop a symptomatic cardiomyopathy. The type of RST-LVEF change that is generally considered a worsening of cardiac performance is a decline greater than or equal to 15%. We had this type of RST-LVEF change, in addition to the 2 CHF, in 5 other patients without symptomatic cardiomyopathy. Nevertheless none of these 5 patients attained pathological values of RST-LVEF, while the 2 CHF showed symptomatic cardiomyopathy only when RST-LVEF became clearly pathologic (less than or equal to 46%). Therefore, although in our study the RST-LVEF changes during CT did not have predictive value for CHF, the method may give a notable clinical contribution all the same. In fact, by submitting the patients with a RST-LVEF fall greater than or equal to 15% to frequent sequential RST-LVEF determinations and stopping the CT if the RST-LVEF becomes pathologic it is possible to avoid severe and irreversible CHF.

Adult↗

Evaluation of right ventricular performance with a right ventricular ejection fraction thermodilution catheter and MRI in patients with pulmonary hypertension.

STUDY OBJECTIVES: We sought to compare catheter studies using a right ventricular ejection fraction (REF) catheter together with echocardiography and MRI in patients with pulmonary hypertension. PATIENTS AND METHODS: We compared hemodynamic findings, echocardiography, and MRI studies in 16 patients with pulmonary hypertension. Six healthy volunteers served as control subjects for the MRI studies. RESULTS: MRI imaging provided accurate assessment of cardiac output in all but two patients. As compared with MRI, the REF catheter constantly underestimated the REF and overestimated right ventricular volumes in patients with pulmonary hypertension. REF, end-systolic and end-diastolic right ventricular volumes, and right ventricular muscle mass, as determined by MRI, were almost identical in patients with preserved cardiac function and those with low-output failure. The only factor that was different in both groups was the severity of tricuspid regurgitation. CONCLUSION: Right ventricular dimensions and muscle mass do not differ in patients with pulmonary hypertension who have low cardiac output and those who do not. According to our results, the major determinant of cardiac output in these patients appears to be the severity of tricuspid regurgitation. The REF catheter provides invalid data on right ventricular dimensions in patients with pulmonary hypertension.

Adult↗

Equilibrium (gated) radionuclide ejection fraction measurement in the pressure or volume overloaded right ventricle. Comparison of three methods.

Although equilibrium radionuclide angiographic measurement of right ventricular ejection fraction (RVEF) has been validated in patients with coronary artery disease, the accuracy of this technique has not been demonstrated in patients with other cardiac diseases which may result in RV pressure and/or volume overload. The accuracy of three methods of equilibrium radionuclide analysis for measuring RVEF was compared in several subgroups of patients with a variety of cardiac diseases, including congenital and valvular heart disease, cor pulmonale, and cardiomyopathy. It was concluded that RVEF may be accurately derived by equilibrium radionuclide ventriculography in patients with a wide variety of cardiac diseases, including those resulting in RV volume and/or pressure overload. Accuracy varies depending on analysis method and the nature of the hemodynamic derangement.

Adult↗