Acute airway obstruction associated with granulation tissue of tracheostoma--a case report.

We report an 85-year-old tracheostomized male patient who underwent ventriculoperitoneal shunt because of hydrocephalus. Postoperative acute airway obstruction and tension pneumothorax developed due to the granulation tissue of tracheostoma which scraped off from the tracheostoma in the act of endotracheal intubation for operation and it lay dormant around until it was drawn into the endotracheal tube (ETT) by negative pressure during suction of trachea in intensive care unit. Persistent hypoxemia in consequence of airway obstruction resulted in cardiac arrest and expiratory seal of trachea eventuated in tension pneumothorax. Flexible fiberoptic bronchoscopy performed during resuscitation disclosed that the obstruction was due to granulation tissue which blocked the ETT lumen. Immediate exchange of endotracheal tube and placement of chest tube made the patient tide over this crisis. No sequela resulted from this crisis and the patient was discharged one week later.

Acute Disease↗

Use of endoscopic trocar-cannula for chest drain insertion in trauma patients and others.

BACKGROUND: The insertion of a chest drain into the pleural space is a common procedure used for treatment in various intrathoracic abnormalities. Recently, a new technique for chest-tube insertion for pleural cavity drainage, using the disposable endoscopic trocar-cannula, was described for the treatment of some pathologic conditions. METHODS: In a prospective study, we used this technique in the treatment of patients with chest trauma, spontaneous and iatrogenic pneumothorax, and various kinds of pleural effusion. RESULTS: One hundred twelve patients were treated by using the endoscopic trocar-cannula for tube insertion into the pleural cavity. Among them, 39 patients were treated after blunt and penetrating chest trauma. Most cannulae were of 10 to 11 mm in diameter, which enabled the insertion of large-bore drain tubes. In five trauma patients, chest-tube insertion was done successfully without antecedent chest x-ray films. The complication rate was 0.89% for intrapulmonary positioning of a chest tube in a patient who had previous ipsilateral thoracic surgery. CONCLUSION: The use of endoscopic trocar-cannulae for chest-tube insertion is a safe, simple, and effective technique for management of trauma and other diverse intrathoracic abnormalities. Its use outside the hospital should be further studied.

Adolescent↗

Streptococcus milleri infections of the pleural space: operative management predominates.

BACKGROUND: Management of patients with thoracic empyema ranges from tube thoracostomy drainage, with or without fibrinolytics, to operative intervention, with the optimal intervention remaining uncertain. Streptococcus milleri, typically a benign bacterium colonizing the oropharynx, has recently been reported as a potential pathogen in pneumonia and pleural space disease. Our initial experience indicated this infection, when in the pleural space, was particularly tenacious and often required major operative intervention to eradicate. Therefore, we hypothesized that patients with S milleri pleural space infections often require operative intervention as definitive treatment. METHODS: We reviewed all patients from June 17, 1999 to April 15, 2005 with S milleri infections at our level I academic trauma/acute care surgery department at a safety-net hospital. S milleri infections were diagnosed by thoracentesis, bronchoalveolar lavage, tube thoracostomy fluid, or intraoperative culture. RESULTS: Over the 70-month period evaluated, of 697 patients with S milleri infections, 39 patients had S milleri infections of the pleural space; 26 (67%) patients underwent operative intervention. The majority (72%) were men with a mean age of 46 (range 22 to 63); the underlying etiology in those patients requiring operation was pneumonia (26 patients; 67%), trauma (9 patients; 23%), postoperative infection (2 patients), foreign body ingestion (1 patient), and malignancy (1 patient). The vast majority of patients in the operative group were treated preoperatively with tube thoracostomy (88%) and antibiotics (96%). The average duration of chest tube drainage prior to operation was 4.4 days (95% confidence interval [CI] 2.6 to 6.2) and antibiotic treatment was 6.0 days (95% CI 3.8 to 8.2). Thirteen patients (50%) underwent video-assisted thoracoscopic surgery (VATS) and 13 patients required thoracotomy. VATS was performed more often when operative intervention occurred early (average hospital day 6.2) compared to initial thoracotomy or conversion from VATS to thoracotomy (average hospital day 9.8). Hospital length of stay was less in the operative group (average 24 days; 95% CI 17 to 31) than in the nonoperative group (34 days; 95% CI 19 to 49), discharge to home was greater in the operative group (77% vs. 16%), and mortality was less in operative group (0% vs. 23%). CONCLUSIONS: Despite attempts at nonoperative management, the majority of patients with a S milleri pleural space infection require operative intervention for definitive therapy. Patients diagnosed with S milleri empyema should be considered for early operative intervention due to the unrelenting nature of their infection. Operative treatment is associated with a shorter hospital length of stay, increased discharge to home, and decreased mortality.

Adult↗

Image-guided drainage techniques.

The basic principles of empyema management center on the initiation of antibiotics and effective pleural space drainage. For patients with empyemas in the exudative or fibrinopurulent stage, image-guided chest tubes have markedly improved patient care. These catheters can be placed into ideal positions within the chest by the use of various imaging techniques to promote effective drainage. Because of a minimal need for tissue dissection, patients tolerate image-guided catheters well with only local anesthetics. Multiple techniques exist to augment tube drainage if necessary. Available approaches include tube exchange with placement of a larger-caliber catheter, tube manipulation, and fibrinolytic therapy. However, success of image-guided catheters depends on proper patient selection, the skills of the operator, and the ability to monitor daily chest tube function to ensure adequacy of drainage. Open surgical procedures can be avoided in most treated patients.

Chest Tubes↗

Advances in thoracostomy tube management.

This article summarizes several of the studies utilizing randomized trials or predetermined algorithms for chest tube management. The classification system, when to use wall suction, when to use water seal, and how to safely discharge patients by the fourth postoperative day-even with air leaks-are outlined.

Algorithms↗

Congenital diaphragmatic hernia in 120 infants treated consecutively with permissive hypercapnea/spontaneous respiration/elective repair.

BACKGROUND/PURPOSE: Poor prognosis (approximately 50% survival rate and significant morbidity) traditionally has been associated with congenital diaphragmatic hernia (CDH). The authors reviewed a single institution experience and challenged conventional wisdom in the context of a care strategy based on permissive hypercapnea/spontaneous respiration/elective repair. METHODS: From August 1992 through February 2000, all infants with CDH and (1) respiratory distress requiring mechanical ventilation, (2) in-born or (3) transferred preoperatively within hours of birth are reported. All respiratory care strategy used permissive hypercapnea/spontaneous respiration and combined with elective repair. Arterial blood gas values and concomitant ventilator support were recorded. Outcome markers were (1) need for extracorporeal membrane oxygenation ECMO, (2) discharge to home, (3) supplemental oxygen need at discharge, and (4) influence of non-ECMO ancillary therapies (surfactant, nitric oxide, high-frequency oscillatory ventilation). RESULTS: One hundred twenty consecutive infants were reviewed. Overall survival rate was 75.8%, but, excluding 18 of 120 not treated (6 lethal anomalies, 10 overwhelming pulmonary hypoplasia, 3 prerepair ECMO-related neurocomplications), 84.4% survived to discharge. A total of 67/120 were inborn. Non-ECMO ancillary treatments had no impact on survival rate. ECMO was used in 13.3%. Surgery was transabdominal; prosthetics were used in 7%. Tube thoracostomy was rare. Every inborn patient (n = 11) requiring a chest tube for pneumothorax died. Respiratory support before surgery was peak inspiratory pressure (PIP), 22, FIO(2),.43 with PaO(2), 66 torr; PaCO(2), 41 torr; and pH, 7.32. The survivors discharged on oxygen (n = 2) died at 4 and 7 months. CONCLUSIONS: The majority of infants with life-threatening CDH treated with permissive hypercapnea/spontaneous respiration/elective surgery survive to discharge with minimal pulmonary morbidity.

Blood Gas Analysis↗

Modified Nuss operation for pectus excavatum: design for decreasing cardiopulmonary complications.

BACKGROUND: Thoracoscopic Nuss operation of funnel chest is increasingly performed. However, it has a high rate of complications. This study developed some modifications to facilitate Nuss operations with the intention of reducing several major complications. METHODS: Patients who presented for surgical repair of pectus excavatum from July 2003 through June 2004 had a preoperative computed tomography (CT) scan, pulmonary function tests, and cardiac echo before and two months after the modified Nuss operation. The following modifications of the standard Nuss procedure were implemented: (1) One small subxyphoid incision was made to guide the plate implantation and to decrease cardiopulmonary complications. (2) Thoracic muscles were dissected off the ribs to provide muscle pockets. (3) Shorter thick stainless-steel AO bars were selected to avoid thoracic outlet syndrome and restriction. (4) The bars were fixed to adjacent ribs by 4-0 stainless steel wires into the submuscular pockets. (5) No thoracoscope routinely used. (6) No chest tubes were placed to decrease chest pain or for cosmetic purposes. RESULTS: 15 patients aged between 4 and 32 years (mean, 18.6 +/- 7.8) underwent evaluation. Preoperative CT index was 4.14 +/- 0.86. The average operating time was 95.7 +/- 27.0 min. There was no bar dislocation, prolonged pain, or neuralgia. Echocardiography showed no pericarditis and no pneumothorax occurred after placement of the intrathoracic bar. CONCLUSION: A small subxiphoid incision makes bar implantation easier and has reduced the incidence of major complications in this early experience with 15 patients.

Adolescent↗

Accuracy of auscultation in the detection of haemopneumothorax.

OBJECTIVE: To assess the accuracy of auscultation in the detection of haemopneumothorax. DESIGN: Prospective study. SETTING: University hospital, Taiwan. PATIENTS: 148 patients with chest injuries admitted between July 1994 and August 1996. MAIN OUTCOME MEASURES: Correlation between the results of auscultation and radiographic findings in 148 patients with injuries to the chest. 83 (56%) had internal injuries, of whom 38 had pneumothoraces, 24 haemothoraces, and 21 haemopneumothoraces. RESULTS: Auscultation had a sensitivity of 84%, a specificity of 97%, an accuracy of 89% and a positive predictive value of 97% in the detection of these injuries. CONCLUSIONS: Auscultation is not as accurate as chest radiography. Chest tubes can be inserted before chest radiography in patients in whom auscultation has indicated an injury. A chest radiograph is essential in those patients with normal breath sounds to exclude a haemopneumothorax that had been missed by auscultation.

Adolescent↗

[A case report of treatment for tracheal fistula after radical esophagectomy].

We report our experience of the treatment of a 60-year-old man with upper tracheal fistula which developed on the 11th day after radical surgery for esophageal cancer. Primary treatment to close the fistula was unsuccessful, resulting in the involvement of empyema due to infection. Controlled ventilation with T-tube and drainage through a chest tube for 2 months lead to depuration of the thoracic cavity. As a strategy for secondary closure of the fistula, fenestration was performed on the 87th day postoperatively. The patient's overall condition improved thereafter and closure was being considered. However, the patient died on the 116th day postoperatively due to supervenient aspiration pneumonia. Thus, long-term controlled ventilation with a T-tube was beneficial for the treatment of central airway injury.

Esophageal Neoplasms↗

Hemopneumothorax following blunt trauma of the thorax.

Hemopneumothorax is a frequent sequel of blunt trauma of the thorax and is easily treated if it occurs without associated injury. As an isolated injury, it is accompanied by a low mortality rate, 2 per cent in this series of 330 patients. The principal treatment for hemopneumothorax was tube thoracostomy with large bore chest tubes. Initial thoracotomy was required for 3.3 per cent of the patients, and late thoracotomy for complications was necessary only in 1.2 per cent of the patients. The over-all mortality rate of 20.3 per cent reflected the many associated injuries. Extrathoracic trauma played a significant role in 44 of the 67 deaths.

Adolescent↗

Perigraft seroma complicating the modified Blalock-Taussig shunts: two consecutive instances with review of literature.

Systemic-to-pulmonary artery shunts using polytetrafluoroethylene (PTFE) (modified Blalock-Taussig shunt) are being used successfully in palliation of cyanotic congenital heart diseases. Graft thrombosis is by far the most common complication of the procedure. Persistant serum leakage through PTFE graft causing perigraft seroma is a rare but devastating complication resulting in increased duration of tube drainage or reinsertion of chest tubes, prolonged hospital stay, and multiple operations. Two consecutive modified Blalock-Taussig shunts complicated by perigraft seroma formation are presented here with review of the literature.

Anastomosis, Surgical↗

An alternative to sutures.

Cyanoacrylate tissue adhesives are used in numerous settings to close wounds without the use of sutures. The product and its use for closing chest tube wounds is discussed.

Chest Tubes↗

[Chylothorax as a rare complication of pancreatitis].

The authors of this study report an extraordinary case which is rather rare even in the medical literature. The patient who suffered from recurrence pancreatitis was taken to hospital in septic condition. In the background of the septic condition lied the acut exacerbate of pancreatitis. Besides, in the right side of the thoracic cavity as well as in the peritoneal cavity fistulas of pancreal tail's pseudocyst was found. It was proved by clinical, laboratory and imaging procedure examinations. During the operation external drainage of the pseudocyst was carried out. After several thoracocentesis chylothorax was developed which was cured by permanent chest tube drainage.

Acute Disease↗

Complication rates of tube thoracostomy.

This study compared the complication rates of tube thoracostomy performed in the emergency department (ED) versus the operating room (OR) and the inpatient ward (IW). A retrospective case series of all patients at an urban, university-based level 1 trauma center hospital who received tube thoracostomy for any indication between 1/1/93 and 12/31/93 was conducted. Complications were defined as empyema, unresolved pneumothorax (persistent air leak or residual pneumothorax), persistent effusion, or incorrect placement. The data for age and duration of tube placement were weighted for analysis of variance (ANOVA). A total of 352 tube thoracostomies was placed in 239 patients. Twenty-three patients had three or more chest tubes placed, 65 had two placed, and the remaining 181 had a single tube. Ninety-nine tubes were placed in the ED, 87 in the OR, and 166 on IW. The mean age of patients in the ED was 37 years, and differed significantly (P < .015) from those in the OR (48 years) and the IW (44 years). The duration of tube placement was similar for all groups (mean = 6.5 days). The overall complication rates related to tube insertion were: ED, 14.0%; OR, 9.2%; IW, 25.3%. Significance was achieved when comparing complication rates between the ED and IW, with less complications in the ED (P = .0436). When comparing complication rates between the ED and OR, there was no significant difference (P = .3643). A power calculation indicated too small of a sample size to truly determine an insignificant difference between complication rates between the ED and OR. Placement of emergent thoracostomy tubes in the ED does not result in an increased complication rate as compared to placement in the IW.

Adult↗

Silicone thorax: a complication of tube thoracostomy in the presence of mammary implants.

Rupture of silicone breast implants is usually either iatrogenic or due to trauma. We present a case of blunt chest wall trauma in a patient with bilateral breast implants. Emergency chest tube thoracostomy resulted in rupture of one of the prostheses and caused subsequent migration of silicone into the chest cavity, where it led to empyema. The patient ultimately required a thoracotomy to evacuate the silicone and decorticate the lung. Review of the literature and methods to avoid this complication are described.

Breast Implants↗

Treatment of early parapneumonic empyema by "medical" thoracoscopy.

We report on a consecutive series of 16 patients with complicated parapneumonic effusion or empyema, in whom, after a failed attempt at tube drainage, thoracoscopy under local anesthesia ("medical" thoracoscopy) was performed for debridement and placement of a chest tube. This approach led to immediate clinical improvement in all patients and to definitive cure in 12 of 16. In 4 patients open surgical debridement was necessary after a few days in an elective procedure. In a subgroup of thoracoscopically treated patients, lung function tests were performed at least 6 months after the procedure and did not demonstrate significant restrictive changes. We conclude that thoracoscopy under local anesthesia is a valuable addition to the treatment options in patients with multiloculated, complicated parapneumonic effusion or empyema not responsive to simple tube thoracotomy. The procedure is less taxing for the patient and less expensive than video-assisted thoracoscopic surgery under general anesthesia or open decortication.

Adult↗

Sensations experienced during removal of tubes in acute postoperative patients.

The major purpose of this study was to determine the types and intensity of sensations that patients experience when chest tubes (CTs) and Jackson-Pratt (JP) abdominal tubes are removed. A convenience sample of 62 hospitalized subjects, 31 with CTs and 31 with JP tubes, participated. Each subject was interviewed after tube removal. Sensations were identified, and intensity of sensation was marked on a 100-mm Visual Analogue Scale. Similar sensations were reported by both groups. Intensity of sensation was consistently higher in the JP group. The most frequently reported sensations were pain (77%) on JP tube removal and pulling (90%) upon CT removal.

Adult↗

Extrapleural suction buttress of primary esophageal repair.

Buttress reinforcement of a primary esophageal repair after perforation may diminish the potential for breakdown or leakage of the approximation. We describe a method of reinforcing a primary esophageal repair by using pleural tissue that is secured in place with an extrapleural, soft T-tube attached to a suction device. This technique is simple to apply and may maximize recovery of respiratory function by permitting timely removal of chest tubes.

Chest Tubes↗