Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

Determination of debrisoquine and 4-hydroxydebrisoquine in urine by high-performance liquid chromatography with fluorescence detection after solid-phase extraction.

A simple, selective and sensitive method has been developed to determine debrisoquine and 4-hydroxydebrisoquine in human urine. Separation of the analytes was obtained using a mobile phase of 0.1 M sodium dihydrogen phosphate-acetonitrile (87:13, v/v) and a muBondapak C18 column. The column effluent was monitored with fluorescence detection at 210 nm (ex) and 290 nm (em). Rapid sample preparation was achieved by solid-phase extraction columns (Bond Elut CBA, 3 ml capacity) which provided excellent recovery values for both compounds. The cost per sample using this approach could be minimized by column regeneration and re-use. The within-day and the day-to-day reproducibilities were less than 7% for both components. The method was shown to be suitable for the study of the debrisoquine-sparteine type genetic polymorphism in man.

Acetonitriles↗

Two derivative spectrophotometric determinations of indapamide in pharmaceutical dosage forms.

Simple, fast and reliable derivative spectrophotometric methods were developed for determination of indapamide in bulk and pharmaceutical dosage forms. The solutions of standard and the sample were prepared in methanol. The quantitative determination of the drug was carried out using the first-derivative values measured at 252.8 nm (N=6) and the second-derivative values measured at 260.4 nm (N=9). Calibration graphs constructed at their wavelengths of determination were linear in the concentration range of indapamide using peak to zero 1.00-30.00 microg ml(-1) for first-derivative and 1.00-35.00 microg ml(-1) for second-derivative spectrophotometric method. The developed methods were successfully applied for the assay of pharmaceutical dosage forms which do not require any preliminary separation or treatment of the samples. The details of the statistical treatment of analytical data are also presented. The results obtained from two derivative spectrophotometry were compared with a spectrophotometric method reported in literature and no significant difference was found statistically.

Dosage Forms↗

Liquid chromatography-mass spectrometry method to determine alcohol ethoxylates and alkylamine ethoxylates in soil interstitial water, ground water and surface water samples.

Alcohol ethoxylates (AEs) and alkylamine ethoxylates (AMEs) are used as adjuvants in pesticide formulations. Analytical procedures for these compounds in environmental aqueous samples using LC-MS are presented. Sample preparation uses solid-phase extraction with Porapak Rdx cartridges. Detection limits and recoveries in ground water and surface water are, respectively, AEs: 16-60 ng/l, 35-93% and AMEs: 0.3-6 microg/l, 28-96%. The lower recoveries are obtained for the apolar surfactants. The procedure was employed on samples of ground water and soil interstitial water collected from farming areas. The individual AEs were detected at concentration levels ranging from 33 to 189 ng/l water.

Alcohols↗

Development of a simplified method for the determination of folates in baker's yeast by HPLC with ultraviolet and fluorescence detection.

A simplified HPLC method for rapid determination of folates in yeast with ultraviolet and fluorescence detection without sample purification has been developed. By use of the column Aquasil C(18), specially designed for polar analytes, and gradient elution, it was possible to separate and determine five folate derivatives: tetrahydrofolate, 5-methyltetrahydrofolate, and 5-formyltetrahydrofolate with fluorescence detection, and 10-formylfolic acid and folic acid with ultraviolet detection. The sample preparation required only a small amount of dry yeast (25-50 mg) and included an extraction of folates by heat treatment and deconjugation of folate polyglutamates to monoglutamates with the use of rat serum conjugase. Validation involved investigation of matrix effects, determination of recovery by standard addition method, repeatability, and stability tests. The dominating folate forms in commercial dry baker's yeast were found to be tetrahydrafolate and 5-methyltetrahydrofolate with a total folate content of 2890 microg/100 g (63.4 nmol/g). The simplicity of the method makes it suitable for folate screening studies of different yeast strains.

Chromatography, High Pressure Liquid↗

Simultaneous multi-determination of brain trace element concentrations by inductively coupled plasma mass spectrometry.

We examined the method of sample digestion and the analytical conditions for simultaneous multi-determination of trace element concentrations by inductively coupled plasma mass spectrometry (ICP-MS) in biological samples. In order to eliminate contaminations by extraneous elements from reagents and instruments, we chose plastic tubes and a Teflon decomposition vessel and super pure grade nitric acid for sample decomposition. Furthermore, standard solutions were prepared by mixing stock solutions of trace elements with a mixture of sample solutions to eliminate matrix interference. Quality control measurements using a standard reference material (SRM bovine liver) showed that the multi-analysis method established in the present study is very accurate and useful for determination of trace element concentrations in biological samples. Using this procedure, we determined the distribution of Zn, Cu, Rb, Mn and Mo in seven discrete regions of the rat brain and Zn and Mn in their synaptosomal fractions.

Animals↗

Fully automated determination of selective retinoic acid receptor ligands in mouse plasma and tissue by reversed-phase liquid chromatography coupled on-line with solid-phase extraction.

A fully automated reversed-phase HPLC method was developed for the quantitative assay of three retinoids (Am-580, CD-2019 and CD-437) which selectively activate the retinoic acid receptors RAR alpha, RAR beta and RAR gamma, respectively. Mouse plasma, embryo and maternal tissues were prepared for injection by on-line solid-phase extraction (SPE) and valve-switching techniques. Following automatic injection, the sample was loaded on preconditioned disposable cartridges, cleaned-up and then transferred onto the analytical column to be eluted in the backflush mode, separated by gradient elution and detected by UV, while a new cartridge was concomitantly conditioned. The overall recovery was quantitative allowing for external standardization. The calibration curves were linear in all biological samples tested so far, with a correlation coefficient (r) >0.99. The intra-day precision was < or = 7.8% (n = 5-6) and the inter-day variability was < or = 9.4% (n = 3). The lower limit of detection was 2.5 ng/ml or ng/g for CD-2019 and CD-437, and 5 ng/ml for Am-580 with a S/N ratio of 5 using a sample weight of 25 microliters or mg. The method is now in routine use in our laboratory for the assessment of the pharmacokinetic profiles of these retinoids. The small sample size required, the simple sample preparation and the rapid analysis with high degree of automation make this method convenient for microanalysis of biological samples both in animal and human studies.

Animals↗

Measurement of the anticancer agent gemcitabine and its deaminated metabolite at low concentrations in human plasma by liquid chromatography-mass spectrometry.

A liquid chromatography/mass spectrometry (LC-MS) method has been developed and validated for the determination of the anticancer agent gemcitabine (dFdC) and its metabolite 2',2'-difluoro-2'-deoxyuridine (dFdU) in human plasma. An Oasis((R)) HLB solid phase extraction cartridge was used for plasma sample preparation. Separation of the analytes was achieved with a YMC ODS-AQ (5 microm, 120 A, 2.0 mm x 150 mm) column. The initial composition of the mobile phase was 2% methanol/98% 5mM ammonium acetate at pH 6.8 (v/v), and the flow rate was 0.2 ml/min. An isocratic gradient was used for 3min, followed by a linear gradient over 4 min to 30% methanol/70% 5mM ammonium acetate at pH 6.8. The gradient returned to the initial conditions over 2 min and remained there for 6 min. The retention times of dFdC, dFdU, and the internal standard 5'-deoxy-5-fluorouridine (5'-DFUR) were 11.46, 12.63, and 13.58 min. The mass spectrometer was operated under negative electrospray ionization conditions. Single-ion-monitoring (SIM) mode was used for analyte quantitation at m/z 262 for [dFdC-H](-), m/z 263 for [dFdU-H](-), and m/z 245 for [5'-DFUR-H](-). The average recoveries for dFdC, dFdU, and 5'-DFUR were 88.4, 84.6, and 99.3%, respectively. The linear calibration ranges were 5-1000 ng/ml for dFdC, and 5-5000 ng/ml for dFdU. The intra- and inter-assay precisions (%CV) were </=3 and </=7% at three concentration levels (50.0, 500, and 5000 ng/ml). The limits of quantitation (defined as 10 times of signal-to-noise ratio) were 3.16 ng/ml for dFdC, and 1.35 ng/ml for dFdU with 50-microl sample injections. This method has been used for measuring plasma concentrations of dFdC and dFdU in samples from adult cancer patients in a Phase I trial of weekly dFdC given as 150 (or lower) mg/(m(2) 24-h) infusion. The average plasma dFdC concentrations at 22- and 23-h into the infusion were 18.3 and 16.8 ng/ml at 150 and 100mg/m(2), respectively; the values for dFdU averaged 2950 and 1372 ng/ml.

Adult↗

Trace analysis of fullerenes in biological samples by simplified liquid-liquid extraction and high-performance liquid chromatography.

Fullerene (C60) has several potential biomedical and industrial applications. While pure fullerene is not soluble in water, nanoparticles of the fullerene aggregates (nano-C60) can be prepared in water solutions. The concentration of nano-C(60) in biological media after systemic exposure could be very low and requires trace analytical methods to be developed for the toxicological and pharmacokinetic studies of the nanomaterial. A serious drop in extraction efficiency was observed when the concentration was under 0.5 microg/mL using traditional liquid-liquid extraction (LLE) protocols. The evaporation of the solvent extract to dryness was found to be the main reason for the efficiency drop and an improved evaporation method was proposed to overcome this problem. Optimal proportion of glacial acetic acid (GAA) was used to solublize the proteins and surfactants in the biological samples, so that the emulsion problem was eliminated during LLE. Magnesium perchlorate was used to destabilize the nano-C60 particles in the water solution and promoted the solvent extraction. A simplified LLE method was developed for high throughput while preserved the advantages of the traditional LLE. The developed method was used for trace analysis of fullerenes in protein containing media and tape-stripped skin samples. Under optimal experimental conditions, the detection limit was 0.34 ng/mL and the recovery was in the range of 94-100% (n=5) at a concentration of 10 ng/mL nano-C60 in the biological media.

Chromatography, High Pressure Liquid↗

Semi-preparative high-performance reversed-phase displacement chromatography of insulins.

A reversed-phase displacement chromatographic method has been developed for the purification of bovine and porcine insulin samples. Up to 500 mg of raw insulin could be purified on a Nucleosil C8 analytical column using a methanol-containing phosphate buffer carrier and a cetrimide-containing displacer. A proinsulin contamination level as low as 100 ppm in the collected fractions could be achieved.

Animals↗

Automated sample preparation for monitoring groundwater pollution by carbamate insecticides and their transformation products.

We investigated automated on-line solid-phase extraction (SPE) followed by liquid chromatographic (LC) techniques for monitoring carbamates and their transformation products. Analytical determinations were performed by LC with UV or postcolumn fluorescence detection (U.S. Environmental Protection Agency Method 531.1 for carbamate insecticides) after preconcentration with on-line SPE using C18 Empore extraction disks. On-line SPE/LC/thermospray mass spectrometry with time-scheduled selected-ion monitoring was used as confirmatory method. The method was used to determine pesticide traces in well waters of a typical aquifer in the Almeria area (Andalucia, south of Spain) from March 1993 to February 1994. The major pollutants, found in highest amounts, were carbofuran, methiocarb, and methomyl, at levels of 0.32, 0.3, and 0.8 micrograms/L, respectively. According to results of seasonal variation studies, pollution by carbamate insecticides is sporadic and exceeds the limit of 0.5 micrograms/L for total pesticides allowed by the European Economic Community Drinking Water Directive only twice a year. 3-Hydroxycarbofuran and methiocarb sulfone also were detected, showing the importance of including the main toxic break-down products of carbamate insecticides in future monitoring programs.

Autoanalysis↗

Circulating levels of cardiac natriuretic peptides (ANP and BNP) measured by highly sensitive and specific immunoradiometric assays in normal subjects and in patients with different degrees of heart failure.

Plasma atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP) levels increase in patients with heart failure with the progression of clinical symptoms and with the deterioration of hemodynamics; consequently, assay methods for these peptides may be useful in the follow-up of cardiac patients. Non-competitive immunoradiometric assay (IRMA) methods for ANP or BNP do not generally require preliminary extraction and/or purification of the plasma sample, and so may be more suitable than competitive immunoradiometric assay (RIA) methods for the routine assay of plasma peptide concentrations. We evaluated the analytical characteristics and clinical usefulness of two IRMAs for plasma ANP and BNP, to verify whether these methods may be considered suitable for the follow-up of patients with heart failure. Both methods are based on the solid-phase sandwich IRMA system, which uses two monoclonal antibodies prepared against two sterically remote epitopes of peptide molecule; the first antibody was coated on the beads solid-phase and the second was radiolabeled with 125I. Blood samples were collected from a brachial vein in ice-chilled disposable polypropylene tubes containing aprotinin and EDTA after the patient had rested for at least 20 min in the recumbent position. Plasma samples were immediately separated by centrifugation and stored at -20 C until assay. The IRMA methods showed a better sensitivity and a wider working range sensitivity (about 2 ng/l) than those of RIA methods. Moreover, the normal range found with these methods (ANP = 16.1 +/- 8.6 ng/l, 5.2 +/- 2.8 pmol/l, BNP = 8.6 +/- 8.2 ng/l, 2.5 +/- 2.4 pmol/l) was similar to that generally reported using the most accurate methods, such as the other IRMAs or RIAs, using a preliminary extraction and purification of plasma samples with chromatographic procedures. Our results obtained in patients with different degrees of heart failure indicate that plasma ANP and BNP increase with the progression of clinical symptoms (NYHA class) (ANOVA p < 0.0001). Indeed, circulating levels of ANP (R = -0.701, no. = 86) and BNP (R = -0.745, no. = 55) were significantly (p < 0.0001) and negatively correlated with the left ventricular ejection fraction values. Furthermore, a close curvilinear regression (R = 0.960, no. = 215) was found between ANP and BNP values, because plasma BNP progressively increases more than plasma ANP in patients with different stages of heart failure. In conclusion, IRMA methods are preferable for the measurement of plasma ANP and BNP for experimental studies and routine assay because they are more practicable, sensitive and accurate than RIA procedures. Finally, BNP assay appears to be better than ANP for discriminating between normal subjects and patients with different degrees of heart failure.

Adult↗

Simultaneous determination of a novel KDR kinase inhibitor and its N-oxide metabolite in human plasma using 96-well solid-phase extraction and liquid chromatography/tandem mass spectrometry.

To support pharmacokinetic studies, a selective and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous determination of a novel KDR kinase inhibitor (1) and its active metabolite (2) in human plasma. The method is fully automated using a Packard MultiPROBE II system and a TomTec Quadra 96 liquid handling workstation to perform sample preparation and solid-phase extraction (SPE). Following the extraction on a mixed-mode SPE using Oasis MCX 96-well plate, the analytes were separated on a Aquasil C18 column (50 mm x 2.1 mm, i.d., 3 microm) with a mobile phase consisting of acetonitrile/ammonium acetate buffer (5 mM, pH 5.0) (60/40, v/v). The run time for each injection was 4.5 min with the retention times of approximately 2.0 and 2.7 min for 1 and 2 respectively, at a flow rate of 0.25 mL/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring (MRM) under the positive ion mode with a turbo ion-spray interface. The linear ranges of the calibration curves were 0.05-400 ng/mL for 1 and 0.1-400 ng/mL for 2 on a PE Sciex API 4000 LC-MS/MS system. The lower limits of quantitation (LLOQ) of the assay were 0.05 and 0.1 ng/mL for 1 and 2 respectively, when 0.4 mL of plasma was processed. Intra-day assay precision (using five standard curves prepared by spiking compounds to five lots of plasma) was less than 4.9% for 1 and less than 9.6% for 2 on each concentration. Assay accuracy was found to be 95.1-104.6% of nominal for 1 standards and 93.5-105.6% for 2 standards. QC samples were stable when kept at room temperature for 4 h, at -70 degrees C for 10 days, and after three freeze-thaw cycles. The extraction recoveries were 80%, 83% and 84% for 1 and 2 and I.S. respectively, and no significant matrix effects were observed. The method was successfully applied to plasma samples from clinical studies after oral administration of compound 1.

Chromatography, High Pressure Liquid↗

Membrane protein and peptide sample handling for MS analysis using a structured MALDI target.

Different sample handling methods for hydrophobic proteins and peptides were evaluated in association with the utilization of a structured matrix-assisted laser/desorption ionization (MALDI) target for increased sensitivity. The fluorinated organic solvent hexafluoroisopropanol (HFIP) was used for the solubilization of both the full-length protein bacteriorhodopsin (BR) and a cyanogen bromide digest thereof, and compared to the performance of the non-ionic detergents octyl-beta-D-glucopyranoside (OG), dodecyl-beta-D-maltoside (DM), and Triton X-100. A concentrating effect was seen when using the structured MALDI plate for BR dissolved in all the different detergents, of which OG generated the best-quality spectra for the full-length integral membrane protein as well as for the hydrophobic peptides. However, the uneven analyte distribution obtained with the detergent preparations required selective and thus time-consuming acquisition of spectra. When instead HFIP was used as sample solvent, a tenfold increase in sensitivity was achieved for full-length BR. Addition of acids to the HFIP-solubilized sample, or to the MALDI matrix solution, improved the signals for a few of the peptides, while degrading the spectra of others. Consequently, the addition of acid could be used as a complementary sample preparation method for hydrophobic peptides. On-target washing to remove contaminants (e.g., salt) was performed, and a recrystallization protocol for signal improvement specifically suited for hydrophobic peptides is described. Results from digestion and solubilization in different micro centrifuge tubes were examined to determine the influence of different materials on the possible sample loss due to wall adhesion. Studies of sample solution storage times suggest immediate analysis after solubilization to obtain best results.

Membrane Proteins↗

Liquid chromatography-mass spectrometry method for the determination of venlafaxine in human plasma and application to a pharmacokinetic study.

A sensitive and selective liquid chromatographic-mass spectrometric (LC-MS) method for the determination of venlafaxine in human plasma has been developed. Samples were prepared using liquid-liquid extraction and analyzed on a C(18) column interfaced with a triple quadrupole mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase was methanol-water containing 10 mmol/L ammonium acetate, pH 7.9 adjusted with aqueous ammonia (80:20, v/v) at the flow rate of 1.0 mL/min. The analyte and internal standard clozapine were both detected by use of selected ion monitoring mode. The method was linear in the concentration range of 1.0-200.0 ng/mL. The lower limit of quantification (LLOQ) was 1.0 ng/mL. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 10.1%. The accuracy determined at three concentrations (5.0, 50.0 and 150.0 ng/mL for venlafaxine) was within +/-10.0% in terms of relative error (RE). The method was successfully applied for the evaluation of pharmacokinetic profiles of venlafaxine capsule in 20 healthy volunteers. The results show AUC, T(max), C(max) and T(1/2) between the testing formulation and reference formulation have no significant difference (p > 0.05). Relative bioavailability was 103.4 +/- 14.1%.

Adolescent↗

Analysis of the Fusarium mycotoxins fusaproliferin and trichothecenes in grains using gas chromatography-mass spectrometry.

A method is described using gas chromatography-mass spectrometry (GC-MS) for the simultaneous detection of the Fusarium mycotoxins fusaproliferin and seven trichothecenes from grains. Sample purification of the raw extract was carried out with commercial solid phase extraction columns, and the recovery of the more polar analytes was increased by rinsing the column with acetonitrile. A significant matrix effect was found for the analysis of fusaproliferin and trichothecenes; thus, the calibrants should be prepared in a blank matrix. The response was linear in the range used. The mean recovery for fusaproliferin was 60.4 or 62.9%, depending on the spiking level. With respect to the trichothecenes, the recovery was generally higher (70.2-125.3%). The method proved to be repeatable for the analysis of fusaproliferin and trichothecenes. The limit of detection for fusaproliferin in the blank matrix mixture was 50 microg/kg, and that for trichothecenes was 5-15 microg/kg. Thirty-eight Finnish grain samples were analyzed for fusaproliferin and trichothecenes with the method developed. Fusaproliferin was not detected in any of the samples. The mean levels of deoxynivalenol, 3-acetyldeoxynivalenol, nivalenol, HT-2 toxin, and T-2 toxin in Finnish grain samples were 272, 17, 150, 40, and <20 microg/kg, respectively.

Edible Grain↗

Isotachophoresis of CSF proteins in gel tubes especially gammaglobulins. An analytical and preparative technique for high-separation of CSF proteins.

An isotachophoretic method using polyacrylamide gel (PAG-ITP) in a simple disc electrophoretic equipment with plastic tubes containing the gels, was elaborated and especially designed for studying the gammaglobulins in CSF and serum from control subjects and patients with neurological disorders, especially known or probable MS. The device and the ITP system used, including leading and terminating electrolytes and spacer substances, dividing the gammaglobulins in a reproducible way, are described. No cooling of the gel tubes was needed. The sample volumes varied between 5--500 microliters, and the separation time was 1.5--3.0 h. CSF from patients with verified or probable MS revealed characteristic, increased low-mobility gammaglobulin fractions. Using other ITP systems, such as other spacer compositions, the anodic proteins can also be studied in more detail. PAG-ITP in gel tubes is a simple and inexpensive technique which can be used for both analytical and preparative procedures for biological material such as CSF, serum and extractions from nervous tissues.

Cerebrospinal Fluid Proteins↗

Simultaneous determination of coumarin, 7-hydroxycoumarin and 7-hydroxycoumarin glucuronide in human serum and plasma by high-performance liquid chromatography.

A HPLC method was developed for the determination of the metabolites of coumarin and 7-hydroxycoumarin in plasma and serum. Separation was based on gradient elution of 7-hydroxycoumarin glucuronide, 7-hydroxycoumarin, coumarin and finally 4-hydroxycoumarin (which is used as an internal standard). Standards, prepared in plasma or serum, and samples were treated with trichloroacetic acid, mixed and centrifuged. The supernatant was removed and analyzed by reversed-phase high-performance liquid chromatography on a C18 column. The limit of detection was 50 ng/ml for 7-hydroxycoumarin and 200 ng/ml for coumarin and 7-hydroxycoumarin glucuronide. The linear range was 0.5-100 micrograms/ml for each of the analytes. The percentage relative standard deviation about the mean measured concentrations were all below 10%. There was no statistical difference between the standard curves prepared in plasma or serum. The method developed was applied to the determination of each of the three compounds in serum, after the administration of 7-hydroxycoumarin, and in plasma after the administration of coumarin. The concentrations of total 7-hydroxycoumarin in the serum samples were also determined by another HPLC method and the results were compared. There was no statistical difference between the results determined.

Chromatography, High Pressure Liquid↗

An isotope-dilution gas chromatography-mass spectrometry method for trace analysis of xylene metabolites in tissues.

A gas chromatography-mass spectrometry (GC-MS) method using isotope dilution was developed to measure trace levels of xylene metabolites in brain tissues. The primary metabolites of xylene are dimethylphenol (DMP), methylbenzyl alcohol (MBA), toluic acid (TA), and methylhippuric acid (MHA). The internal standard was a mixture of deuterated DMP-d3, TA-d7, and MHA-d7. DMP-d3 was commercially available and was used as the internal standard for both DMP and MBA. TA-d7 and MHA-d7 were biosynthesized by administering xylene-d10 to rats and collecting their urine. Based on the noise peaks in 10 blank samples, the on-column limits of quantitation (mean +10 SD of noise peaks) were approximately 305, 1220, 545, and 386 pg for DMP, MBA, TA, and MHA, respectively. Analyte detection and recovery tests from brain tissues of control rats were conducted by spiking the tissues with 32 nmol/g of each analyte, together with the deuterated metabolites. The tissues were homogenized, extracted with ethyl acetate, and derivatized by trimethylsilylation. One microliter of the sample was injected into the GC-MS. The recoveries of the analytes were 104 +/- 8%, 80 +/- 9%, 93 +/- 10%, and 92 +/- 11% (mean +/- SD, n = 7) for DMP, MBA, TA, and MHA, respectively. The tissue preparation efficiency, which was indicated by absolute recoveries of internal standards, was approximately 33% for DMP, MBA, and TA and approximately 80% for MHA. No metabolites were detected in untreated control tissues. This simple and sensitive method to simultaneously detect major xylene metabolites in brain tissues could also be used for the analysis of blood and urine samples from workers to monitor p-xylene exposure.

Animals↗