Search PubMedSearch

SEARCH · Search PubMed

Results for “hyperspectral imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

154 records · Page 5Linked to original sources

Physician-Modified Fenestrated Stent-Grafts Planned Using Three-Dimensional Techniques for Complex Aortic Pathology: A Systematic Review and Meta-Analysis.

BACKGROUND: Complex aortic pathology involving the visceral arteries remains a significant therapeutic challenge. Open repair is associated with considerable perioperative risk, particularly in patients with multiple comorbidities, while standard endovascular aneurysm repair (EVAR) is often not feasible because of inadequate proximal sealing zones. Fenestrated and branched endovascular repair (F/BEVAR) represents an established treatment strategy; however, the use of custom-made devices is limited by manufacturing time and availability. Physician-modified stent grafts (PMSGs) have therefore emerged as a pragmatic alternative. Three-dimensional planning techniques have been increasingly used to facilitate accurate graft modification. The aim of this systematic review and meta-analysis was to evaluate the effectiveness and safety of PMSG procedures planned with three-dimensional techniques. Technical success, target vessel patency, early mortality, endoleak occurrence, and reintervention rates were analyzed. METHODS: A systematic search was conducted in the PubMed/MEDLINE and Embase databases. Studies describing the use of physician-modified fenestrated stent grafts planned with three-dimensional tools were included. Meta-analyses were performed using a random-effects model with restricted maximum likelihood estimation. A logit transformation was used for the analysis of proportions. RESULTS: The analysis included five studies involving 172 patients. The estimated weighted mean follow-up duration was 14.9 months. The overall technical success rate was 92.9% (95% confidence interval [CI]: 84.5-96.9%), with low-to-moderate heterogeneity. Target vessel patency was 96.9% (95% CI: 93.6-98.5%). Early mortality was 5.5% (95% CI: 2.1-13.3%). The incidence of endoleaks was 13.3% (95% CI: 5.8-27.4%), with significant heterogeneity among studies. Reinterventions were reported in 6.6% of patients (95% CI: 2.3-17.5%). CONCLUSION: The results indicate that PMSG procedures planned with three-dimensional techniques are associated with a high rate of technical success and preserved patency of target vessels in patients with complex aortic pathology. The observed variability in endoleak and reintervention rates likely reflects differences in anatomical complexity and patient selection among studies. Further prospective studies are needed to confirm long-term outcomes.

Humans

Paramedian supracerebellar transtentorial approach for Yaşargil T2 tentorial incisura meningiomas.

OBJECTIVE: Tentorial incisura meningiomas, particularly those arising from the middle incisural region (Yaşargil T2), are surgically challenging because of their deep location and compression of critical neurovascular structures. These lesions typically have supratentorial or infratentorial extension but can also extend across both compartments. Although approach selection is often guided by the dominant compartment of tumor extension, for lesions with supratentorial-dominant extension, the optimal approach remains controversial, and a standardized strategy has not been established. Authors of this study evaluated the feasibility and outcomes of the paramedian supracerebellar transtentorial (PST) approach for Yaşargil T2 tentorial incisura meningiomas with a supratentorial-dominant or combined extension. METHODS: The authors retrospectively reviewed data from consecutive patients with radiographic and intraoperative findings consistent with a Yaşargil T2 tentorial incisura lesion treated via the PST approach from September 2005 through December 2025. Patients were placed in a semisitting position whenever feasible and in a semilateral position when semisitting was contraindicated. Collected data included demographics, tumor extension patterns, extent of resection on postoperative MRI, neurological outcomes, histopathology, rate of recurrence, and follow-up. RESULTS: Six patients, 1 male and 5 female, with an overall mean age of 43 years, underwent resection via the PST approach. Four lesions had predominantly supratentorial extension, and 2 had combined supra- and infratentorial growth, with no cases of isolated infratentorial extension. Five patients had been placed in the semisitting position and 1 in a semilateral position because of a cardiac contraindication to the semisitting position. No new permanent neurological deficits were observed. Postoperative MRI showed Simpson grade I resection in all 6 patients. The mean follow-up was 8.6 years. Histopathological analysis revealed 3 WHO grade 1 meningiomas, 1 WHO grade 2 meningioma (clear cell), and 2 solitary fibrous tumors (meningioma mimics). These diagnoses were evaluated according to the 2021 WHO classification. CONCLUSIONS: In this consecutive series, the PST approach was a viable single-corridor strategy for Yaşargil T2 tentorial incisura lesions, including supratentorial-dominant tumors, achieving Simpson grade I resection with no permanent neurological deficits. By providing early devascularization at the tentorial attachment and a gravity-assisted, retractorless working corridor with favorable deep venous visualization, the PST approach challenges compartment dominance as the primary determinant of approach selection.

Humans

Efficacy of current approaches to non-invasive diagnosis of skin cancer and the potential impact of artificial intelligence: A systematic review and meta-analysis.

BACKGROUND: Skin cancer is one of the most prevalent malignancies worldwide, particularly within Caucasian populations. This systematic review and meta-analysis aimed to quantitatively review the current literature on non-invasive diagnosis of skin cancer and evaluate the current evidence to support the use of tools in addition to, or in replacement of clinician face-to-face assessment. METHODS: A literature search was conducted for publications in PubMed, Medline and Embase databases. Articles describing accuracy, sensitivity, specificity and outcomes of their mode of assessment were included. A total of 208 articles met the inclusion criteria. RESULTS AND CONCLUSION: This systematic review and meta-analysis showed that the diagnostic performance of artificial intelligence (AI) in the interpretation of dermatoscopic images was high for melanoma diagnosis, basal cell carcinoma or malignancy, in comparison to dermatoscopic assessment alone by clinicians and experts. Although AI interpretation of images demonstrated higher sensitivity for melanoma diagnosis in comparison to clinical assessment combined with dermatoscopic assessment, it is unclear if this is also the case for basal cell carcinoma and squamous cell carcinoma diagnosis. Reflectance confocal microscopy, a non-invasive high resolution imaging technique, is known to have a high sensitivity for diagnosing cutaneous malignancy, and this may have applications within secondary care. Therefore, AI could help reduce resource burden and aid in clinical assessment, particularly within primary care settings.

Humans

Depression and amyloid-β across CSF, PET, and plasma biomarkers: a systematic review and meta-analysis.

Alzheimer's disease is increasingly defined by biomarker evidence of amyloid-β and tau pathology, sharpening questions about whether late-life depression contributes to, or instead reflects, this pathology. We conducted a systematic review and meta-analysis of studies published between 2000 and 2025 that compared amyloid-β biomarkers in adults with and without depression, with depression defined by validated clinical diagnoses or symptom rating scales. Twenty-four studies were included, spanning three biomarker sources: cerebrospinal fluid, positron emission tomography imaging, and plasma. Across all sources, the pooled difference in amyloid-β burden between depressed and non-depressed individuals was small and clustered near zero, indicating only a weak, statistically non-significant tendency toward higher amyloid in depression. When the three sources were examined separately, each yielded a similar near-null result, although between-study heterogeneity was considerable for cerebrospinal fluid and plasma and moderate for imaging. Importantly, a prespecified subgroup analysis showed that imaging results diverged by quantification method: studies using the simpler standardized uptake value ratio clustered around zero, whereas the smaller group of studies using kinetic distribution volume ratio modelling showed a significant positive association, suggesting that methodological choices critically influence the observed relationship. Taken together, these findings indicate that depression is not consistently accompanied by greater amyloid-β burden across widely used biomarker platforms. The distribution volume ratio signal nonetheless raises the possibility of subtle associations that cruder methods may obscure, and suggests that depression may shape Alzheimer's disease trajectories more by modifying the clinical impact of amyloid than by altering its amount.

Humans

Artificial intelligence-supported double reading in European population breast cancer screening: A systematic review and meta-analysis of prospective programs.

BACKGROUND: Most European population mammography screening programs rely on double reading with arbitration, a model that delivers mortality benefit but is increasingly challenged by radiologist workload, variable specificity, and interval cancers. Artificial intelligence (AI) is being evaluated to support or optimize these established European screening pathways. PURPOSE: To synthesize prospective or program-embedded evaluations of AI conducted within European-style population screening programs and to estimate exploratory program-level absolute risk differences (RDs) per 1000 examinations for cancer detection rate (CDR) and recall. MATERIALS AND METHODS: We performed a prespecified, focused evidence synthesis of three large studies embedded within routine population screening programs operating under European-relevant workflows: MASAI (randomized AI-supported risk triage within a national program), ScreenTrustCAD (prospective paired-reader evaluation with AI as an independent reader in a double-reading framework), and PRAIM (nationwide decision-referral implementation). Outcomes were harmonized as AI-control RDs per 1000 examinations. Random-effects pooling used Hartung-Knapp-Sidik-Jonkman models. For the paired-reader design, sensitivity analyses applied a Kish effective sample-size approach across plausible within-examination correlations (ρ = 0.3-0.8). Positive predictive value (PPV) and workflow/time outcomes were summarized descriptively. RESULTS: Across 597,419 examinations, the pooled CDR RD was +0.9 per 1000 (95% CI -0.0 to +1.8; I2 ≈ 12%), consistent with a modest directional increase with borderline statistical uncertainty. The pooled recall RD was -0.6 per 1000 (95% CI -3.1 to +2.1; I2 ≈ 41-43%), indicating no consistent recall increase across screening programs. Where reported, PPV was higher with AI-supported screening. Efficiency signals included 44.3% fewer total readings in MASAI and shorter reading times for AI-normal examinations in PRAIM; in PRAIM, a program-level safety-net mechanism recovered 204 cancers that would otherwise have been missed. CONCLUSION: In European population screening programs characterized by double reading and arbitration, prospective program-embedded evidence suggests that AI integration may yield a small absolute increase in cancer detection (≈1/1000) without a consistent increase in recall, alongside improved PPV and efficiency signals. These findings suggestAI primarily as a complementary reader within European screening workflows, with implementation requiring explicit quality assurance and monitoring of interval cancers and stage distribution.

Humans

IgA Vasculitis with necrotizing arteritis: a multicenter retrospective study from the French Vasculitis Study Group and systematic review of the literature.

IgA vasculitis (IgAV) primarily affects small vessels, but rare cases with necrotizing arteritis (NA) raise questions about overlap with polyarteritis nodosa (PAN). To characterize IgAV with necrotizing arteritis (IgAV-NA) and compare its phenotype with classical IgAV and PAN. We performed a multicenter retrospective study combined with a systematic literature review (1990-2025). Patients fulfilled EULAR/PRINTO/PRES IgAV criteria, had pathological or imaging evidence of NA in small or medium arteries, and were ANCA-negative. Thirty patients were included (7 from databases, 23 from the literature). NA was confirmed by biopsy (n = 16) or vascular imaging (n = 14). Clinical features, treatments, remission, and mortality were compared with 257 adult IgAV and 196 PAN patients. Median age was 54.5 years. IgAV-NA was characterized by severe manifestations, including gastrointestinal bleeding, perforation, surgical abdomen, neuropathy, pancreatitis, and livedo. Compared with classical IgAV, IgAV-NA showed significantly higher rates of multi-organ involvement and mortality. Compared with PAN, IgAV-NA shared vascular complications but had less fever and neuropathy. Despite arterial involvement, patients did not fulfil PAN criteria. IgAV-NA represents a rare, severe IgAV phenotype with life-threatening complications rather than an IgAV-PAN overlap. Severe or atypical IgAV presentations should prompt vascular imaging and intensified immunosuppression.

Humans

Changes in hippocampal functional connectivity and volume associated with cognitive improvement and decline in amnestic mild cognitive impairment following computerized cognitive training.

BACKGROUND: The hippocampus influences the outcomes of amnestic mild cognitive impairment (aMCI) and undergoes different changes during the cognitive decline or recovery of aMCI compared to elderly individuals with normal cognition, which may reveal disease-dependent neurodegeneration or plasticity. We first aimed to investigate the hippocampal changes associated with cognitive changes in aMCI using a combined case-control study design. METHODS: In total, 50&#x202f;aMCI individuals and 50 healthy controls (HCs) were recruited in Shenyang, China, and separately randomized into training and control groups: aMCI training group, aMCI no training group, HC training group, and HC no training group. The aMCI and HC training groups received computerized cognitive training (CCT) thrice weekly for 12 weeks. Cognitive assessments and MRI data were collected at baseline and follow-up. RESULTS: The primary outcome was significant CCT&#xd7;diagnosis interaction effect on the change in cognitive performance as measured by clock drawing test (CDT) scores (F&#x202f;=&#x202f;4.322, P&#x202f;=&#x202f;0.041); this interaction was driven by CCT specifically in aMCI (F&#x202f;=&#x202f;4.465, P&#x202f;=&#x202f;0.038). Significant CCT&#xd7;diagnosis interaction effects of right-hippocampal FC changes were observed in the bilateral precuneus/cuneus (Pvoxel<0.05) driven by CCT in aMCI (F&#x202f;=&#x202f;5.429, P&#x202f;=&#x202f;0.023), and in the left superior temporal gyrus/middle temporal gyrus (STG/MTG, Pvoxel<0.05), driven by CCT of only in HCs (F&#x202f;=&#x202f;6.587, P&#x202f;=&#x202f;0.013). A significant interaction effect of left-hippocampal FC changes were observed in the right triangular part of the inferior frontal gyrus (IFGtriang, Pvoxel<0.05), driven by CCT in aMCI and HCs (F&#x202f;=&#x202f;6.550, P&#x202f;=&#x202f;0.013; F&#x202f;=&#x202f;7.097, P&#x202f;=&#x202f;0.010). No significant interaction effect on the change in hippocampal GMV was noted (P&#x202f;>&#x202f;0.05). CONCLUSION: CCT can improve the visuospatial ability of aMCI, which is reflected by the CDT scores. CCT can alter hippocampal FC in the bilateral precuneus/cuneus, the right IFGtriang, and the left STG/MTG. The hippocampal GMV is difficult to change in both HCs and aMCI during the cognitive decline. REGISTRATION NUMBER: ChiCTR1900026849. DATE OF REGISTRATION: 24 October 2019 NAME OF TRIAL REGISTRY: Chinese Clinical Trial Registry (ChiCTR).

Humans

Cognitive-metabolic relationship in temporal lobe epilepsy: A systematic review.

OBJECTIVE: To summarize the current literature on neurometabolic dysfunction identified through brain imaging and its cognitive correlates in temporal lobe epilepsy (TLE). BACKGROUND: Cognitive decline contributes to chronic disability in TLE. The pathophysiology of cognitive decline in TLE is poorly understood, limiting therapeutic advances. Characterizing metabolic changes in patients with TLE and cognitive impairment may identify biomarkers and inform new treatment strategies. DESIGN/METHODS: We conducted a systematic review of five major databases, gathering studies published through December 2024, in accordance with PRISMA guidelines. We included all observational studies describing associations between metabolic imaging findings and cognitive measures in TLE. RESULTS: Of 1449 reports, 38 met the inclusion criteria, encompassing 1161 patients with TLE aged 5-66&#xa0;years. Twenty-two studies applied fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) to assess interictal brain glucose metabolism. Two studies utilized PET with other tracers to assess more specific metabolic aspects. Fourteen studies used proton magnetic resonance spectroscopy (1H-MRS) to quantify local concentrations of brain metabolites. Impairment of verbal memory was consistently associated with left temporal lobe metabolite changes. Non-memory cognitive impairments correlated with changes in glucose metabolism, N-acetylaspartate, and gamma-aminobutyrate in both temporal and extratemporal areas. CONCLUSION: 18F-FDG PET remains the most widely used imaging modality to assess cognitive-metabolic correlates in TLE, while other PET tracers and 1H-MRS are potentially underexplored. Verbal memory impairment correlates robustly with left temporal dysmetabolism. Cognitive impairment in TLE is multifaceted and correlates with measurable changes in metabolism in both temporal and extratemporal regions. While our synthesis was restricted by some methodological limitations, these neurometabolic signatures may hold promise as potential biomarkers for identifying risk of cognitive decline and highlight avenues for future research.

Humans

Phase-resolved functional lung MRI detects single-dose and sustained bronchodilator responses in COPD in a randomized crossover trial.

OBJECTIVES: To evaluate the effects of tiotropium/olodaterol (T/O) on phase-resolved functional lung (PREFUL) MRI parameters in hyperinflated chronic obstructive pulmonary disease (COPD) patients and examine correlations with conventional cardiopulmonary and hyperpolarized 129Xe MRI measures. MATERIALS AND METHODS: Retrospective subanalysis of a prospective, randomized, placebo-controlled, crossover trial with open-label extension. Thirty-two patients with moderate-to-severe COPD (61.5&#x2009;&#xb1;&#x2009;7.7 years; 17 men); 30 completed the MRI extension at 1.5&#x2009;T. PREFUL analysis yielded regional ventilation (RVent), flow-volume loop correlation metric (FVL-CM), normalized perfusion (QN), ventilation defect percentage (VDP), perfusion defect percentage (QDP), V/Q match metrics (VQM), and pulmonary pulse wave velocity (PWV; post-hoc parameter). Linear mixed-effects models tested treatment effects; correlations were evaluated with Spearman's rank and bootstrap 95% confidence intervals (95% CIs). RESULTS: PREFUL parameters improved after T/O single dose (SD) versus placebo, including improvements in FVL-CM by 4.1 percentage points (pp; 95% CI: 1.0 to 7.3 pp) and QN by 0.4 pp (95% CI: 0.2 to 0.6 pp) and reductions in VDP and QDP, with parallel gains in VQM(Non-Defect) (p&#x2009;<&#x2009;0.05). PWV decreased after multiple doses (-0.87&#x2009;m/s, 95% CI: -1.26 to -0.48&#x2009;m/s). PREFUL MRI baseline values showed significant correlations with pulmonary function tests, cardiac, dynamic contrast-enhanced and 129Xe MRI. SD treatment-induced absolute changes in VDP(FVL-CM) correlated with reductions in residual volume (&#x3c1;&#x2009;=&#x2009;0.41, 95% CI: 0.02 to 0.64). Further correlations were observed between PREFUL MRI and &#xb9;&#xb2;&#x2079;Xe-derived VDP, apparent diffusion coefficient, and compartment ratios. CONCLUSION: PREFUL MRI sensitively captured immediate SD T/O-induced improvements in V/Q parameters and dose-dependent PWV responses after sustained bronchodilation. KEY POINTS: Question Can phase-resolved functional lung (PREFUL) MRI sensitively capture immediate single-dose and sustain multi-dose effects of tiotropium/olodaterol on ventilation-perfusion and vascular function in COPD patients? Findings Tiotropium/olodaterol improved PREFUL MRI-derived ventilation, perfusion, and V/Q matching parameters after a single dose, with sustained pulmonary vascular improvements after repeated dosing. Clinical relevance PREFUL MRI detected immediate and sustained functional improvements after tiotropium/olodaterol and showed significant correlations with cardiopulmonary tests and hyperpolarized &#xb9;&#xb2;&#x2079;Xe MRI, supporting its role as a sensitive, radiation-free tool for monitoring COPD treatment response.

Humans

Beyond predictive performance: A systematic review and critical methodological appraisal of AI/ML and conventional modelling strategies in breast, colorectal, and pancreatic Cancer.

BACKGROUND: Predictive modelling for cancer risk, treatment-related complications, and survival is central to precision oncology. Conventional logistic regression (LR) and Cox proportional hazards (CoxPH) regression remain widely used but are limited when modelling nonlinear interactions, high-dimensional imaging features, and multimodal clinical-metabolic predictors. Artificial intelligence (AI) and machine learning (ML) methods offer expanded capability through automated feature extraction, ensemble learning, and flexible survival modelling, but the evidence on when AI/ML adds value over conventional models across cancer sites and predictive tasks remains fragmented. OBJECTIVE: To systematically evaluate the methodological performance, validation strategies, and translational limitations of AI/ML models compared with conventional statistical models in published predictive-modelling studies for breast, colorectal, or pancreatic cancer. METHODS: PubMed, Scopus, and Web of Science were searched for studies published between January 2019 and March 2025. Two reviewers independently conducted title-and-abstract screening, full-text eligibility assessment, and PROBAST risk-of-bias assessment. Sixty-five studies (n&#xa0;=&#xa0;907,567 participants) were narratively synthesised by cancer site, predictive task, model family, comparator, validation strategy, predictor modality, and calibration or explainability reporting. RESULTS: The 65 studies comprised breast cancer (n&#xa0;=&#xa0;35), colorectal cancer (n&#xa0;=&#xa0;21), and pancreatic cancer (n&#xa0;=&#xa0;9). AI/ML superiority over LR and CoxPH was task- and data-dependent. CNN- and U-Net-based models predominated in imaging and body-composition tasks, tree-based ensembles consistently outperformed LR for tabular perioperative complication prediction, and CoxPH remained competitive, and in the largest pancreatic risk study, superior to XGBoost (C-index 0.802 vs 0.723) in well-structured datasets. PROBAST analysis-domain risk was moderate in 54 of 65 studies (83%), driven by limited external validation, sparse calibration reporting (11/65), and few decision-curve analyses (7/65). CONCLUSION: AI/ML adds the most methodological value in imaging-derived feature extraction and nonlinear perioperative prediction, while conventional regression remains preferable in large, structured datasets with linear predictors. Clinical translation requires standardised body-composition definitions, external validation, calibration assessment, decision-curve analysis, and explainability, in line with TRIPOD+AI and CLAIM standards.

Humans

Vestibular schwannoma associated normal pressure hydrocephalus: clinical features and shunt responsiveness compared with idiopathic NPH.

BACKGROUND: Vestibular schwannoma (VS) is commonly associated with obstructive hydrocephalus due to mass effect; however, a rarer communicating form resembling normal pressure hydrocephalus (NPH) has also been described, possibly related to impaired CSF absorption from elevated CSF protein. We aimed to characterize the clinical and imaging features of VS-associated NPH (VS-NPH) and compare them with those of an idiopathic NPH (iNPH) cohort. METHODS: We retrospectively analyzed 18 patients with VS-NPH identified between 2008 and 2024. For comparison, 41 iNPH patients were drawn from a prospective longitudinal study at our center. Variables included demographics, tumor size, VS treatment modality, CSF parameters, Radscale imaging features, and shunt responsiveness. RESULTS: VS-NPH patients had markedly higher CSF protein levels than patients with iNPH (median 100 vs. 51&#xa0;mg/dL, p&#xa0;<&#xa0;0.001). Radiological features largely overlapped; however, parasagittal sulcal narrowing was more frequent in VS-NPH (61&#xa0;% vs.13&#xa0;%, p&#xa0;=&#xa0;0.002). These differences remained significant in the sensitivity analysis excluding the two patients without gait impairment. VS-NPH patients were younger in the primary analysis (66.8 vs. 72.0&#xa0;years, p&#xa0;=&#xa0;0.03), while exploratory associations between larger tumor size and both earlier NPH symptom onset (r&#xa0;=&#xa0;-0.48, p&#xa0;=&#xa0;0.049) and smaller callosal angle (r&#xa0;=&#xa0;-0.49, p&#xa0;=&#xa0;0.048) attenuated to non-significant trends in the sensitivity analysis. Tumor size was&#xa0;<&#xa0;30&#xa0;mm in 89&#xa0;% of patients. Ventriculoperitoneal shunt (VPS) resulted in clinical improvement in both groups, although response rates were numerically lower in VS-NPH than in iNPH (63&#xa0;% vs.75&#xa0;%). CTT was positive in 9 of 11 VS-NPH patients who underwent testing, although improvement after shunting also occurred in patients with negative CTT results or without prior CTT. CONCLUSIONS: VS-NPH may represent a secondary subtype of NPH with distinct biochemical and subtle imaging features. Elevated CSF protein may contribute to altered CSF dynamics. These findings are exploratory and require confirmation in larger prospective studies.

Humans

The wider erection angle in hypospadias: A neglected feature affecting surgical outcomes.

INTRODUCTION: Penile curvature often accompanies hypospadias, and numerous techniques have been described for its correction; however, in some cases, an abnormal erection angle may also be present, further exacerbating the perception of curvature. OBJECTIVE: This study investigates the significance of the erection angle in hypospadias cases and its correlation with the severity of the anomaly. STUDY DESIGN: A retrospective analysis of intraoperative photographs of hypospadias cases operated between 2019 and 2023 was performed. Erection angle was measured with a digital goniometer during a full artificial erection. Erection angles in proximal and distal hypospadias cases were analyzed and compared to data from Kinsey's subgroups representing healthy male erection angles. RESULTS: This study involved images of 68 patients, with 31 having proximal and 37 distal hypospadias. The median age of the whole group was 11 months (6-156, IQR 9). Median erection angle was 91 (63-119, IQR 11) for distal cases, whereas it was 96 (75-138, IQR 21) for proximal cases. The difference was statistically significant (p = 0.009). The erection angle distribution in our cohort, including both proximal and distal hypospadias cases, skewed toward wider angles, highlighting a distinct pattern compared to data constituted by Kinsey and Sparling. DISCUSSION: Our findings indicate that the erection angle in hypospadias is significantly wider in proximal cases, suggesting a correlation between erection angle and severity of the hypospadias. While we acknowledge the limitation of comparing our prepubertal cohort with Kinsey's adult data, the absence of evidence suggesting significant post-pubertal changes in erection angle justifies this approach. Additionally, the use of digital images for angle assessment is not a standardized technique in hypospadias evaluation; these images were initially captured for curvature assessment. Despite these limitations, our study provides novel insights into seldom mentioned association with hypospadias - a wide erection angle, emphasizing the need for further research on its implications for surgical planning and long-term outcomes. CONCLUSION: This study introduces a wider erection angle as an additional characteristic of hypospadias particularly pronounced in proximal cases. To our knowledge, this is the first focused investigation on addressing this aspect of the condition. It emphasizes the need for further research on adults with wide post-repair erection angles to explore its long-term impact on sexual function and aesthetics.

Humans

Beyond Photometric Consistency: Addressing Loss Insensitivity to Depth Noise in Endoscopic Estimation via Error Calibration.

Self-supervised monocular depth estimation in endoscopy is fundamentally constrained by the ill-posed nature of photometric supervision. In this work, we identify a critical yet overlooked cause of this ambiguity: the inherent insensitivity of photometric loss to depth noise. To overcome this intrinsic limitation, we propose Depth Error Calibration Learning (DECL), a two-stage framework that suppresses prediction variance and mitigates residual errors in self-supervised depth estimation. In Stage I (Variance Reduction), a cyclic depth generation strategy produces multiple depth hypotheses for the input image. The per-pixel empirical variance is quantified and integrated into a dedicated variance loss term, which penalizes inconsistent predictions and encourages the network to generate more stable and reliable depth estimates. In Stage II (Bias Calibration), an image-conditioned diffusion model refines the Stage-I depth prior and mitigates structured residuals through iterative denoising, thereby improving geometric accuracy and global consistency. Extensive experiments on three public endoscopic datasets demonstrate that DECL achieves consistent improvements over representative self-supervised monocular depth estimation methods under the evaluated protocols. Moreover, ablation studies on two representative backbones indicate that DECL is not restricted to a single network implementation, while broader validation on additional backbone families remains necessary. The source code is publicly available at https://github.com/DavidLuBit/EndoDenoising.

Journal Article

Extending the Treatment Window for Intravenous Thrombolysis in Acute Ischemic Stroke: An Updated Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Intravenous thrombolysis (IVT) is the standard treatment for acute ischemic stroke within 4.5 hours of onset. However, imaging-based selection may extend the treatment window. This systematic review and meta-analysis evaluated the efficacy and safety of IVT administered beyond 4.5 hours after stroke onset or last known well (LKW) in patients selected based on imaging findings. METHODS: A comprehensive search of PubMed, Scopus, and Cochrane Library was performed to identify randomized controlled trials comparing IVT with alteplase or tenecteplase (TNK) administered >4.5 hours after stroke onset/LKW vs standard care. Primary outcomes were 3-month excellent (modified Rankin Scale [mRS] 0-1) functional outcome and symptomatic intracranial hemorrhage (sICH). Secondary outcomes included good (mRS 0-2) functional outcome, recanalization, and 3-month mortality. Pooled odds ratios (ORs) with 95% confidence intervals (CIs) were calculated using random-effects models. Subgroup analysis assessed differences between alteplase and TNK. RESULTS: Fourteen studies involving 4,944 patients were included. The mean age was 69.8 years, 58.2% were male, the median National Institutes of Health Stroke Scale score was 9, and 12.3% received preplanned endovascular thrombectomy (EVT). A total of 2,492 patients received IVT in an extended time window (4.5-24 hours). Compared with standard care, extended IVT was associated with higher odds of achieving an excellent functional outcome (OR: 1.43 [95% CI 1.25-1.63]), a good functional outcome (OR: 1.25 [95% CI 1.11-1.40]), and recanalization (OR: 3.28 [95% CI 2.09-5.16]). There was no difference in 3-month mortality (OR: 1.21 [95% CI 0.95-1.53]). However, IVT increased the risk of sICH (OR: 2.51 [95% CI 1.47-4.28]). Sensitivity analysis excluding patients who received EVT showed no impact on the outcomes. TNK exhibited similar efficacy to alteplase but showed potentially lower odds of sICH (OR: 1.96, 95% CI 1.06-3.64) compared with alteplase (OR: 5.29, 95% CI 1.80-15.57); however, the subgroup difference was not significant (p = 0.11). DISCUSSION: Among patients selected based on imaging, 4.5-24 hours after stroke onset/LKW, IVT improves outcomes despite an increased risk of sICH. TNK showed similar efficacy to alteplase, with a possible lower risk of sICH; however, direct comparisons in future trials are needed.

Humans

Isometric Exercises for Tendinopathies: A Systematic Literature Review.

PURPOSE: Musculoskeletal disorders are among the most common reasons for medical consultation, with tendinopathies accounting for up to 30% of such presentations. Although exercise remains the cornerstone of management, the most effective modality continues to be debated. Eccentric exercise has long been the mainstay, but the role of isometric exercise in pain modulation and functional recovery remains unclear. This systematic review aims to evaluate the current evidence on the efficacy of isometric exercises in the management of tendinopathies across various anatomic sites. METHODS: A systematic search was conducted in PubMed, MEDLINE, Embase, and the Cochrane Library from inception to August 1, 2025. Eligible studies included randomized controlled trials and prospective or retrospective cohort studies assessing isometric exercise interventions for tendinopathy, with or without comparator groups. Case series and case reports were excluded. Data extracted included participant demographic characteristics, site of tendinopathy, symptom duration, treatment duration, adherence, and outcome measures such as Victorian Institute of Sports Assessment (A, P, or G), visual analog scale, Patient-Specific Functional Scale, 36 item short form health survey (SF-36), and EuroQol 5-Dimension questionnaires. Imaging outcomes (ultrasound or magnetic resonance imaging) were recorded where available. Methodological quality and risk of bias were assessed using the Cochrane Risk of Bias tool in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. FINDINGS: The search identified 304 articles, of which 13 randomized controlled trials met the inclusion criteria, encompassing 336 participants (40% female). Tendinopathy sites included the patellar (n = 4), Achilles (n = 3), lateral elbow (n = 2), rotator cuff (n = 2), wrist extensor (n = 1), and gluteal (n = 1) tendons. Median symptom duration was 23 months (interquartile range, 3-51 months). Intervention periods ranged from a single 45-minute session to 4-month exercise programs. Treatment adherence was high initially (nearly 100%) but declined over time, with 70% of participants in the isometric and 58% in the control (isotonic) groups completing &#x2265;80% of sessions. Pain reduction and functional improvement were statistically significant in only 3 studies. Imaging-based outcomes were inconsistently reported, and study heterogeneity precluded meta-analysis. Overall methodological quality was rated as good in 3 studies and poor in 10. IMPLICATIONS: Current evidence provides limited support for the superiority of isometric exercise in tendinopathy management. Although isometric regimens appear tolerable and may confer short-term analgesic benefits, their long-term efficacy relative to eccentric or isotonic protocols remains uncertain. Future research should prioritize standardized outcome measures, longer follow-up, and uniform diagnostic criteria to strengthen the evidence base for exercise prescription in tendinopathies.

Humans

Automated CEAP Classification of Venous Duplex Reports Using Multimodal Artificial Intelligence.

OBJECTIVE: To develop and internally validate a prototype multimodal artificial intelligence system for automated CEAP (Clinical, Etiological, Anatomical and Pathophysiological) classification of venous duplex ultrasound (VDUS) reports, integrating natural language processing of free-text components with computer vision analysis of hand-drawn anatomical diagrams. METHODS: Single centre retrospective observational study using routinely collected clinical data. One thousand consecutive venous duplex ultrasound reports from Cambridge University Hospitals NHS Foundation Trust, UK (July 2024 - May 2025) were labelled according to the CEAP classification, excluding the Etiological component, which could not be reliably determined from duplex reports alone. Transfer learning was applied using ClinicalBERT for text and MobileNetV3 for diagrammatic data. Clinical classes were predicted from request line text. Text- and image-based pathophysiological models were developed for four anatomical territories (Great Saphenous Vein, Small Saphenous Vein, Deep system, Perforators), combined using late fusion with probability averaging. RESULTS: The clinical CEAP model achieved accuracy of 0.91, macro-F1 of 0.82, and macro-AUC of 0.98. Pathophysiological prediction varied, with text models broadly outperforming image models. Fusion yielded heterogeneous benefits, improving SSV performance but reducing Deep system accuracy. The performance of the final pathophysiological CEAP fusion models varied across anatomical territories: accuracy ranged from 0.70-0.92 and macro-AUC from 0.80-0.92. CONCLUSION: This study demonstrates the feasibility of automated CEAP classification from VDUS reports. Despite class imbalance affecting minority class predictions, the strong discriminatory performance validates this multimodal ML model for extracting clinically meaningful information from real-world data. This approach offers potential, pending external validation, to streamline vascular services through automated triage and guideline-compliant decision making.

Artificial intelligence

Cerebrovascular involvement in Erdheim-Chester disease: a case report and systematic literature review.

BACKGROUND: Intracranial perivascular/vascular infiltrations and stenoses related to Erdheim-Chester disease (ECD), often associated with ischemic events, are rarely documented. This study aims to characterize intracranial perivascular/vascular infiltrations and stenoses. METHODS: We first report a new case of strokes revealing ECD with intracranial arterial involvement. We then searched all English- and French-language publications from database inception to November 2025 across 12 different search interfaces, including grey literature sources. Vascular involvement was defined by the presence of intracranial perivascular/vascular infiltrations and stenosis on imaging and/or histopathological evidence of small-vessel involvement. Cases with intracranial nodules or masses abutting vessels but without clear longitudinal perivascular infiltration were excluded. RESULTS: We present a case of recurrent strokes with intracranial vertebral and basilar artery wall stenosis, and aortitis. Initially diagnosed as giant cell arteritis, the patient was treated with corticosteroids, cyclophosphamide followed by methotrexate, but relapsed. The identification of tibial osteosclerosis led to the diagnosis of ECD, with a favorable response to anakinra. Twelve relevant articles were retrieved, in addition to our own case. Most patients exhibited focal cerebrovascular signs (11/13) and associated parenchymal involvement (11/13). Intracranial perivascular/vascular infiltrations and stenoses involved the carotid arteries (7/13), the vertebrobasilar arteries (1/13), or both territories (4/13). Aorta was involved in 8/12 cases. Among the nine patients with available follow-up data, five had poor overall or neurovascular outcomes. CONCLUSIONS: Intracranial perivascular/vascular infiltrations and stenoses, which leads to recurrent focal ischemic events, represents a likely underdiagnosed CNS pattern in ECD, referred to as "cerebrovascular ECD", which worsens overall prognosis. Vascular imaging should be included in brain MRI protocols for patients with ECD, given the overlap with parenchymal involvement.

Humans

Artificial Intelligence for Diagnosing Meibomian Gland Dysfunction: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies.

PURPOSE: To identify, appraise, and synthesize the performance of artificial intelligence-based meibography reading as compared with human graders in diagnosing meibomian gland dysfunction. METHODS: We followed Cochrane methodology and reporting guidelines for diagnostic test accuracy reviews. To assess potential risk of bias and applicability, we used a modified Quality Assessment of Diagnostic Accuracy Studies-2 checklist. We applied bivariate logistic models to estimate summary sensitivity and specificity when appropriate and used the GRADE framework to rate the certainty of the evidence. RESULTS: We identified 14 eligible studies involving 5511 predominantly middle-aged participants (average age: 27-55 years) who were primarily female (&#x2265;54.5%). A total of 18,926 meibography images were obtained through noncontact infrared (11 studies) or in vivo confocal microscopy (three studies). Two studies reported external validation of deep learning models, 12 reported internally validated models, and one reported both. All but one study had high risk of bias in at least one domain; 12 studies raised high or intermediate concern about applicability. Based on three external evaluations, the summary sensitivity and specificity for diagnosing meibomian gland dysfunction from normal glands were 97.5% (95% confidence interval: 77.5%-99.8%) and 85.5% (95% confidence interval: 47.3%-97.5%). Sources of heterogeneity in internally validated models included study population, case mix, and others. The overall evidence was very low to low certainty because of imprecision, high risk of bias, and concerns about applicability. CONCLUSIONS: Artificial intelligence-based meibography grading appears less accurate than human graders. Future studies should adopt rigorous designs, including a more diverse participant pool (or image set), and external validation.

Humans