At least 91 records · Page 5Linked to original sources

Calcium biosensing with a sol-gel immobilized photoprotein.

Aequorin, the bioluminescent protein found in the jellyfish Aequorea sp., has been immobilized in a porous sol-gel glass environment. The luminescence from this protein is specifically triggered by the presence of calcium ions, thus offering exciting possibilities for the development of an optical biosensor for this cationic species. The luminescence emission spectrum has been measured from the aequorin protein after interaction with calcium ions. The intensity of the luminescence, measured at the peak maximum of 470 nm, for the encapsulated protein has been calibrated against calcium ion concentration. The characterization of the protein within the sol-gel matrix has been reported together with biosensing experiments using human sera and milk samples. The results suggest that the sol-gel encapsulated aequorin protein offers potential as a one shot bioluminescence based biosensor for the determination of calcium ions in such complex matrices.

Biosensing Techniques↗

Double-stranded DNA liquid-crystalline dispersions as biosensing units.

Three different approaches to constructing biosensing units based on double-stranded (ds) DNA molecules, capable of detecting various biologically active compounds, are considered. The first approach is based on the abnormal optical activity of the liquid-crystalline dispersion formed from ds DNA molecules, modified by relevant physical factors or treated with biologically active compounds. The second one is based on the abnormal optical activity of the liquid-crystalline dispersions formed first from the ds DNA and then treated with coloured biologically active compounds. The third one is based on the abnormal optical activity, specific to particles of the liquid-crystalline dispersions, where the neighbouring DNA molecules are crosslinked by artificial polymeric bridges. These approaches permit the detection of biologically relevant compounds of various origins.

Biosensing Techniques↗

Online and in situ monitoring of environmental pollutants: electrochemical biosensing of cadmium.

Online sensitive monitoring of gene expression is essential for understanding microbial life and microbial communities, especially under stress-inducing conditions, such as the presence of environmental pollutants. We describe here a novel use of promoter-based electrochemical biosensing for online and in situ monitoring of gene expression in response to pollutants. As a model system, we used a cadmium-responsive promoter from Escherichia coil fused to a promoterless lacZ gene, which was monitored using an electrochemical assay of beta-galactosidase activity. This whole-cell biosensor could detect, within minutes, nanomolar concentrations of cadmium in water, sea water and soil samples, and it can be used for continuous online and in situ monitoring.

Adenosine Triphosphatases↗

Repeat region engineering of Cas13a crRNA enables conformational gating-based autocatalytic CRISPR biosensing.

CrRNA engineering has emerged as a pivotal strategy for extending CRISPR-Cas13a biosensing. However, structural modulation of the direct repeat (DR) region remains exceptionally challenging due to its intricate architecture and the high energetic barrier of the Cas13a-crRNA interface, which is conventionally viewed as a rigid and immutable scaffold. Here, we demonstrate that the DR region is instead a programmable topological element with unexpected structural plasticity. By systematically engineering the DR through sequence insertion and structural splitting, we identified multiple DR variants that retain robust catalytic activity. Crucially, this topological reconfiguration enables Cas13a activity to be precisely gated by unmodified nucleic acid blockers, a level of regulation unattainable with the wild-type crRNA. Building on this flexible modulation, we developed Dre-CRISPR, a DR-engineered platform that couples target-triggered DR restoration to a self-reinforcing autocatalytic loop. This self-amplifying system provides a 2 × 106-fold sensitivity enhancement over nonamplified systems. Furthermore, the Dre-CRISPR platform extends the diagnostic scope of Cas13a to a broader spectrum of analytes, ranging from microRNAs to enzymatic activities and heavy metal ions. Our findings redefine the crRNA scaffold as a versatile signaling node and provide a generalizable framework for developing high-sensitivity, self-amplifying CRISPR biosensors through topology-driven guide RNA engineering.

CRISPR-Associated Proteins↗

Electrochemical biosensing with nanoparticles.

This minireview looks at the latest trends in the use of nanoparticles (NPs) in electrochemical biosensing systems. It includes electrochemical characterization of NPs for use as labels in affinity biosensors and other applications. DNA analysis involving NPs is one of the most important topics of current research in bionanotechnology. The advantages of the use of NPs in designing novel electrochemical sensors for DNA analysis are reviewed. Electrochemical NPs can also be used in designing immunoassays, offering the possibility of easy, low cost and simultaneous detection of several proteins. Research into NP applications in electrochemical analysis is in its infancy. Several aspects related to sensitivity as well integration of all the assay steps into a single one need to be improved.

Animals↗

Rapid and sensitive screening of antifungal activity in medicinal plants by a single-cell biosensing system.

A biosensing system based on the response of fungal cells was used for the evaluation of antifungal activity of medicinal plants against Aspergillus niger. This system measured the hyphal growth rate in real time in the presence or absence of Chinese herbal extracts. The sensitivity of this system was 100-fold higher than that of conventional methods, and is advisable for the screening of antifungal compounds.

Antifungal Agents↗

M-DNA: a self-assembling molecular wire for nanoelectronics and biosensing.

M-DNA is a complex between divalent metal ions such as Zn2+ and duplex DNA which forms at pH 8.5. Unlike B-DNA, M-DNA does not bind ethidium so that M-DNA formation can be monitored conveniently by an ethidium fluorescence assay. M-DNA was shown to be a better conductor than B-DNA by fluorometric measurements of electron transport in donor-acceptor labelled duplexes; by direct conductivity measurements of M-DNA bound between gold electrodes and by cyclic voltammetric studies on ferrocene labelled duplexes attached to gold microelectrodes. As is the case with B-DNA, M-DNA can self-assemble into a variety of structures and is anticipated to find widespread use in nanoelectronics and biosensing.

Biosensing Techniques↗

Influence of D-glucose on lipid solid support membrane system as attempt for biosensing of medically relevant molecules.

The influence of D-glucose on a lipid solid support system with the aid of impedance spectrocopy as a preliminary attempt for the biosensing of medical relevant molecules was studied. In spite of some shortcomings, s-BLM's proved to be an appropriate model for the study of lipid membrane-D-glucose interactions. The shortcomings were the roughness of the metal support, and the lack of homogeneity in the monolayer or multilayer lipid structures.

Biosensing Techniques↗

Biosensing in California.

Worldwide sales of medical biosensors now exceed pounds 2.8 billion (Euro 4.1 billion) per annum and applications of biosensing technology are highly relevant to United States homeland security. A recent mission funded by the United Kingdom government to California, USA, investigated some of the development work going on there.

Biosensing Techniques↗

Feasibility of continuous glutamate monitoring in perfused retinal tissue with a potentiometric biosensing probe.

A potentiometric biosensing probe for glutamate has been evaluated as a possible tool to measure the release of glutamate from the isolated retina of Bufo marinus. This probe is based on carbon dioxide detection, following enzymatic conversion of glutamate to gamma-aminobutyric acid (GABA) via glutamic acid decarboxylase (GAD). Probe response characteristics of dynamic range, limit of detection, pH dependency, and selectivity are described. Probe modifications were required for sensor operation in an upside down configuration which was demanded by the need to mount and perfuse the retinal tissue directly at the sensor tip. Overall, these results indicate that this particular potentiometric biosensor is not well suited for direct glutamate measurements in retinal tissue because of pH incompatibility between the sensor and the tissue, and because of high background carbon dioxide levels released from the retina at the pH optimum of the probe. Despite this drawback, the sensor could be utilized to provide a continuous "downstream" monitor of glutamate levels during the course of an experiment, after pH buffering of tissue perfusate. Alternative approaches to probes more compatible with direct tissue measurements are discussed.

Animals↗

The development and application of biosensing devices for bioreactor monitoring and control.

Presently, few of the reported (bio)chemical sensor devices have found application in fermentation monitoring and control. Although many devices with desirable selectivities have been reported, few have demonstrated reliability sufficient to encourage significant and widespread application. Chemical sensors (ion-selective electrodes, amperometric detectors, piezoelectric, field-effect transistors, semiconductor, Optrode and optoelectronic sensors), biosensors (based on potentiometric, amperometric, field-effect transistor and conductiometric detectors) and physical detection methods are reviewed with the aim of highlighting the problems of their application in this area. Physical detection principles appear to show promise as reliable and direct monitoring principles. However, even the more reliable discrete (bio)chemical sensor devices require the development of on-line flow sampling and autocalibration methods to demonstrate the necessary reliability. Biosensor devices appear most problematical and it is concluded that continued development of more direct biosensing principles is likely to prove most fruitful.

Biological Products↗

DRESSA: biosensing of dioxin and dioxin-like chemicals using secreted alkaline phosphatase.

In this article, we describe a highly sensitive biosensing system, DRESSA, for detection of dioxin and dioxin-like chemicals. Tandem copies of the dioxin-responsive element (DRE) fused to a minimal viral promoter were subcloned into an expression plasmid upstream of a secreted alkaline phosphatase (SEAP) gene. When murine hepatoma cell line Hepa-1c1c7 was stably transfected with this construct, established sensor clones secreted SEAP following stimulation with 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). A clone HeDS49 was found to be extremely sensitive; it secreted SEAP in response to TCDD in dose- and time-dependent manners, and the minimal detection limit was 100 fM. To detect more than 6 pM of TCDD, the whole assay time (from cell seeding to measurement of SEAP activity) could be reduced to 4h. Secretion of SEAP was induced selectively by other activators of DRE (3-methylcholanthrene, benzo[a]pyrene, and beta-naphthoflavone) but not by activators of unrelated responsive elements. These data suggested that because of the rapidity, easiness, specificity, and high sensitivity of DRESSA, it is more suitable than currently available detection systems for dioxin and dioxin-like chemicals and would be of great advantage to high-throughput screening of these pollutants in environmental samples.

Alkaline Phosphatase↗

Synthesis of a series of oligo(ethylene glycol)-terminated alkanethiol amides designed to address structure and stability of biosensing interfaces.

A strategy for the synthesis of a series of closely related oligo(ethylene glycol)-terminated alkanethiol amides (principally HS(CH(2))(m)CONH(CH(2)CH(2)O)(n)H; m = 2, 5, 11, 15, n = 1, 2, 4, 6, 8, 10, 12) and analogous esters has been developed. These compounds were made to study the structure and stability of self-assembled monolayers (SAMs) on gold in the prospect of designing new biosensing interfaces. For this purpose, monodisperse heterofunctional oligo(ethylene glycols) with up to 12 units were prepared. Selective monoacylation of the symmetrical tetra- and hexa(ethylene glycol) diols as their mesylates with the use of silver(I) oxide was performed. The synthetic approach was based on carbodiimide couplings of various oligo(ethylene glycol) derivatives to omega-(acetylthio) carboxylic acids via a terminal amino or hydroxyl function. SAM structures on gold were studied with respect to thickness, wettability (water contact angles approximately 30 degrees ), and conformation. A good fit was obtained for the relation between monolayer thickness (d) and the number of units in the oligo(ethylene glycol) chain (n): d = 2.8n + 21.8 (A). Interestingly, the corresponding infrared spectroscopy analysis showed a dramatic change in conformation of the oligomeric chains from all-trans (n = 4) to helical (n > or = 6) conformation. A crystalline helical structure was observed in the SAMs for n > 6.

Journal Article↗

Immediate effect of Biosense guided percutaneous direct myocardial revascularization with holmium:yttrium aluminium garnet laser on myocardial contractility assessed by transesophageal echocardiography.

OBJECTIVE: To evaluate immediate changes in left ventricular wall motion in patients treated using Biosense direct myocardial revascularization laser system. METHODS: Regional wall motion in 10 patients undergoing catheter-based direct myocardial revascularization using a holmium:yttrium aluminium garnet laser was assessed by transesophageal echocardiography before and immediately after the procedure. RESULTS: Mild deterioration in wall-motion score occurred rarely for only three of 160 (1.9%) segments and did not induce clinical heart failure. CONCLUSION: With the current catheter-based laser myocardial revascularization strategy, mild deterioration in wall motion of treated segments was rarely observed and did not effect overall left ventricular function or induce clinical congestive heart failure.

Aged↗

Zinc biosensing with multiphoton excitation using carbonic anhydrase and improved fluorophores.

Previously, we had shown that the zinc-dependent binding of certain fluorescent aryl sulfonamide inhibitors could be used with apocarbonic anhydrase II to transduce the level of free zinc as a change in the fluorescence of the inhibitor. While inhibitors such as dansylamide, ABD-M, and ABD-N made possible quantitation of free zinc in the picomolar range with high selectivity, they have only modest absorbance which limits their utility. We describe here the synthesis and properties of two new probes, Dapoxyl sulfonamide and BTCS, and their use in zinc biosensing. Dapoxyl sulfonamide exhibits a dramatic increase and blue shift in its emission upon binding to holocarbonic anhydrase II, as well as a 20-fold increase in lifetime: it is thus well suited for quantitating free Zn(II) down to picomolar ranges. The anisotropy of BTCS increases fivefold upon binding to the holoprotein, making this probe well suited for anisotropy-based determination of zinc. BTCS and ABD-N are efficiently excited with two photon excitation using 1.5 ps pulses from a titanium sapphire laser, and exhibit the increased zinc-dependent anisotropy response anticipated on the basis of photoselection.

Anisotropy↗

Advances in Single-Molecule Immunoassay: From Counting Strategies to CRISPR-Enhanced Biosensing.

Single-molecule immunoassays (SMIs) overcome the sensitivity limitations of conventional bulk measurements by enabling a paradigm shift from analog to digital signal readouts, thereby facilitating highly sensitive quantification of ultra-low-abundance biomarkers for precision diagnostics. This review provides a systematic overview of recent advances in SMI technologies and the conceptual framework underlying their evolution. First, discretization strategies for single-molecule counting are classified into hard discretization, based on physical confinement, and soft discretization, based on spatiotemporal isolation, within heterogeneous and homogeneous assay systems, respectively. The fundamental mechanisms by which these strategies mitigate diffusion limitations and enhance signal-to-noise ratios are discussed. Second, the integration of SMIs with CRISPR-based diagnostic systems (CRISPR-dx) is examined, with particular emphasis on their complementary roles in target recognition and signal amplification. Finally, recent applications of SMIs in the diagnosis of oncological, neurological, infectious, and cardiovascular diseases are summarized, along with a critical discussion of current engineering challenges and future directions toward clinical translation.

Immunoassay↗