Strategies for muscle activation during isometric torque generation at the human elbow.

1. We studied the patterns of electromyographic (EMG) activity in elbow muscles of 14 normal human subjects. The activity of five muscles that act in flexion-extension and forearm supination-pronation was simultaneously recorded during isometric voluntary torque generation, in which torques generated in a plane orthogonal to the long axis of the forearm were voluntarily coupled with torques generated about the long axis of the forearm (i.e., supination-pronation). 2. When forearm supination torques were superimposed on a background of elbow flexion torque, biceps brachii activity increased substantially, as expected; however, brachioradialis and brachialis EMG levels decreased modestly, a less predictable outcome. The pronator teres was also active during pure flexion and flexion coupled with mild supination (even though no pronation torque was required). This was presumably to offset inappropriate torque contributions of other muscles, such as the biceps brachii. 3. When forearm supination torque was superimposed on elbow extension torque, again the biceps brachii was strongly active. The pronator teres also became mildly active during extension with added pronation torque. These changes occurred despite the fact that both the pronator and biceps muscles induce elbow flexion. 4. In these same elbow extension tasks, triceps brachii activity was also modulated with both pronation or supination loads. It was most active during either supination or pronation loads, again despite the fact that it has no mechanical role in producing forearm supination-pronation torque. 5. Recordings of EMG activity during changes in forearm supination-pronation angle demonstrated that activation of the biceps brachii followed classic length-tension predictions, in that less EMG activity was required to achieve a given supination torque when the forearm was pronated (where biceps brachii is relatively longer). On the other hand, EMG activity of the pronator teres did not decrease when the pronator was lengthened. Triceps EMG was also more active when the forearm was supinated, despite its having no direct functional role in this movement. 6. Plots relating EMG activity in biceps brachii, brachialis, and brachioradialis at three different forearm positions revealed that there was a consistent positive near-linear relationship between brachialis and brachioradialis and that biceps brachii is often most active when brachioradialis and brachialis are least active. 7. We argue that, for the human elbow joint at least, fixed muscle synergies are rather uncommon and that relationships between muscle activities are situation dependent.(ABSTRACT TRUNCATED AT 400 WORDS)

Elbow↗

Cat hindlimb muscles exert substantial torques outside the sagittal plane.

1. We studied the contributions of several hindlimb muscles to ankle torque in adult cats deeply anesthetized with pentobarbital sodium. Isometric torques were measured with a multiaxis, force-moment sensor connected to the plantar surface of the foot. 2. Individual muscle torques were provoked by using a combination of muscle nerve stimulation and selective denervations and tenotomies. Torques were represented by three orthogonal components; defined as dorsiflexion/plantarflexion, inversion/eversion (rotation about the long axis of the foot), and toe-in/toe-out (rotation about the axis of the tibia). 3. Most of the muscles tested exerted substantial torques about more than one of the orthogonal axes, each of which shared a common origin centered midway between the medial and lateral malleoli. The lateral and especially the medial head of the gastrocnemius muscle exhibited large toe-out torques and eversion torques as well as the classical plantarflexion components. 4. The torque exerted by tibialis anterior was seen to oppose that of both medial and lateral gastrocnemius in each of the three directions. The toe-in and inversion torques exerted by tibialis posterior was opposed in these directions by both peroneus brevis and peroneus longus. Flexor hallucis longus exerted approximately 10 times more plantarflexion torque than did flexor digitorum longus; therefore, these two muscles cannot be considered pure synergists. 5. The major plantarflexors and dorsiflexor of the cat ankle joint contribute substantial torques outside the sagittal plane. Their opposing torques lead to increased joint stiffness; the net effect of coactivation of these muscles causes ground reaction forces oriented so as to maintain stability during quadrupedal stance.

Animals↗

Intraoperative insertion torque of lumbar pedicle screw and postoperative radiographic evaluation: short-term observation.

The correlation between the insertion torque of a lumbar pedicle screw and the mechanical stability of the screw in the bone has been mentioned in in vitro studies. The purpose of this study was to confirm the factors affecting the insertion torque of such screws in vivo. Also, the contribution of insertion torque to the initial stability of the fusion area was to be analyzed in vivo. A series of 23 cases representing 50 lumbar vertebrae were included in this study, in which we examined bone mineral density using quantitative computed tomography (CT) prior to operation. Two screw shapes were utilized, with the insertion torque for each screw measured at two points in time. The correlation between insertion torque and mineral density was investigated. Screw positions were confirmed on postoperative CT scans, and the effect of the screw thread cutting into the cortex bone was investigated. Radiographic changes at three points during a period of 3 months were also measured, and we then evaluated the interrelations between these changes and insertion torque. Furthermore, the relation between insertion torque and instability at 3 months was investigated. Correlations of insertion torque and bone mineral density depended on screw shape. There was no correlation found with mineral density in the case of cylindrical screws. Insertion torque was not affected by the screw thread cutting into the cortex of bone. As for postoperative alignment changes, no definitive trends could be ascertained, and no interrelations with torque and alignment changes were observed. There is a possibility that insertion torque was related to early-stage stability, but no statistical relation could be determined.

Aged↗

Accuracy of the Nouvag torque control motor for nickel-titanium rotary instruments.

OBJECTIVES: To determine the torque output and examine the accuracy of 5 Nouvag torque control motors. STUDY DESIGN: A handpiece was attached to the motor and gripped with a vise. A size 50 Orifice Shaper, with a 0.07 mm/mm taper was inserted in the handpiece. The instrument tip was clamped in a chuck connected to a torque sensor. Four torque settings were evaluated at 350 rpm. Ten tests were done at each torque setting. A new instrument was used for each test. The means of the torque values generated by the motors at the different torque levels were analyzed using analysis of variance and the Student t test. RESULTS: The actual torque values were significantly higher than the torque preset on the motor (P<.0001) and did not differ significantly among the motors (P>.05). CONCLUSIONS: The actual torque deviated from the preset torque. The usefulness of these motors is questionable.

Analysis of Variance↗

The effects of ACL injury on quadriceps and hamstring torque, work and power.

The aim of this study was to assess isokinetic torque, work and power between non-injured, ACL (anterior cruciate ligament)-deficient and ACL-reconstructed individuals. Ten healthy, non-injured individuals, seven unilateral ACL-deficient individuals and six unilateral ACL-reconstructed individuals were assessed for isokinetic quadriceps and hamstring strength at 1.05 and 3.14 rad.s-1. Peak torque, total work, average power and the ratio of peak torque to body mass were computed for both velocities. Peak torque was also corrected for body mass, using allometric modelling. The non-injured individuals showed significantly greater quadriceps peak torque to body mass ratios than the ACL-deficient and ACL-reconstructed individuals at both velocities, and greater hamstring peak torque to body mass ratios than the ACL-deficient group at 3.14 rad.s-1 (P < 0.05). The ACL-deficient individuals displayed greater quadriceps and hamstring peak torque, total work and average power than the non-injured individuals at 1.05 rad.s-1 (P < 0.05). The ACL-deficient individuals also displayed significantly greater peak torque, total work and average power than the ACL-reconstructed individuals for the quadriceps at both velocities (P < 0.05). The ACL-deficient individuals demonstrated greater hamstring peak torque and total work than the non-injured individuals at both velocities (P < 0.05). The allometrically modelled peak torques at both isokinetic velocities demonstrated that the quadriceps muscle values were significantly higher in the non-involved than the involved limb. The hamstring peak torques corrected for body mass were significantly higher in the non-involved than the involved limb only at 1.05 rad.s-1. The main finding from the present study is that isokinetic measures in ratio-scaled or absolute units yield a different outcome and, hence, interpretation compared with the allometric approach.

Adult↗

Can insertional torque predict screw loosening and related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion.

STUDY DESIGN: An investigation of the relation between intraoperative insertional torque of pedicle screws, bone mineral density of the vertebra, and development of screw loosening in vivo. OBJECTIVES: To determine the usefulness of intraoperative measurement of the insertional torque of pedicle screws. SUMMARY OF BACKGROUND DATA: Some biomechanical studies have demonstrated that the insertional torque is highly correlated with bone mineral density and the stability of pedicle screws in vitro. METHODS: Pedicle screw fixation was performed with posterior lumbar interbody fusion in 62 consecutive patients. The mean age of the patients at the time of surgery was 58 years. The insertional torque of pedicle screws was measured intraoperatively in all patients. The mean follow-up period was 2.7 years. RESULTS: The mean insertional torque was 1.28 +/- 0.37 Nm in patients with screw loosening and 1.50 +/- 0. 40 Nm in patients without the problem. The mean insertional torque in patients with compression fractures in the upper vertebra adjacent to the fixed segment was 0.83 +/- 0.23 Nm. There was no significant difference between the mean insertional torque in patients with screw loosening and those without the condition. The mean insertional torque in patients without screw loosening was significantly greater than in patients with compression fractures (P < 0.01). A high correlation was found between insertional torque and bone mineral density (P < 0.01). CONCLUSIONS: Although a high correlation was found between the insertional torque of pedicle screws and bone mineral density in vivo, the insertional torque could not objectively predict screw loosening.

Bone Density↗

Accuracy of the TCM Endo III torque-control motor for nickel-titanium rotary instruments.

The purpose of this study was to determine the torque output and examine the accuracy of five TCM Endo III torque control motors. A handpiece was attached to the motor and gripped with a vise. A 0.07 taper Orifice Shaper, size 50, was inserted in the handpiece. The instrument tip was clamped in a chuck connected to a torque sensor. Four torque settings were evaluated at 350 rpm. Ten tests were performed at each torque setting. A new instrument was used for each test. The means of the torque values generated by the motors at the different torque levels were analyzed using analysis of variance and post-hoc pairwise comparisons with the Bonferroni test. The actual torque values were significantly higher than the torque preset on the motor (p < 0.0001) and did not differ significantly among the motors (p > 0.05). The actual torque deviated from the preset torque. The usefulness of these motors is questionable.

Analysis of Variance↗

Effects of fatigue on the torque-velocity relation in muscle.

BACKGROUND: The extent to which fatigue is related to the velocity of shortening is still not fully understood. OBJECTIVES: To examine the effects of fatigue induced by maximal intensity exercise at different velocities on subsequent torque-velocity relations in muscle. METHODS: Ten men (mean (SD) age 25 (3) years; stature 1.78 (0.34) m; body mass 80.6 (14.5) kg) provided written informed consent and, over a five day period in a randomised manner, performed 16 fatiguing bouts of maximal intensity exercise on an isokinetic dynamometer each followed by one repetition maximum action. Concentric peak torque of the preferred leg was assessed at angular velocities of 0.52, 1.05, 2.09, and 3.14 rad/s. Mechanical work performed for all fatiguing bouts was held at 3050-3150 J. After a 45 second rest, a maximum effort was performed at one of the preset velocities. As a baseline, dependent variables of peak torque (N.m), angle of peak torque (rad), and mean torque (N.m) were measured at each velocity. An analysis of covariance was used to compare torque-velocity relations, and one factor, within subject analyses of variance with repeated measures investigated differences from baseline. RESULTS: Torque-velocity relations for all dependent variables did not differ (p>0.05). Similarly, angles at which peak torque occurred were not velocity dependent and did not differ from baseline and subsequent exercise measures (p>0.05). Generally, fatiguing exercise at low velocities led to reductions in peak and mean torque in subsequent exercise at higher velocities (p<0.05). CONCLUSIONS: Torque-velocity relations fundamentally remain intact after fatigue induced at any velocity, although the magnitude changes. The results suggest that the greater decline in torque during subsequent exercise at high velocities could be due to greater exhaustion of fatigue sensitive type II fibres, whereas low velocity subsequent exercise is less affected because of the greater use of type I fibres.

Adult↗

Accuracy of mechanical torque-limiting devices for implants.

PURPOSE: To examine the accuracy of 3 mechanical torque wrenches. MATERIALS AND METHODS: The torque outputs of the Nobel Biocare, Straumann ITI, and DynaTorq ITL mechanical torque-limiting devices were determined using a special setup on an Instron test machine. The devices were held in the test setup and oriented so that activation of the drivers caused a pure torsion effect. RESULTS: Significant differences generally existed between individual units and the target torque levels for the Nobel Biocare torque controller. DISCUSSION: The mean torque values of the ITI and ITL devices were within 10% of their respective target torque levels. Knowledge of applied torque levels to the screws that retain implant abutments and their attached prostheses is necessary to achieve optimal preload. The ITI and ITL devices tested in this study were capable of providing consistent torque at or near their respective targets. CONCLUSION: The torque output of each individual device deviated in varying degrees from target torque values.

Analysis of Variance↗

Torques generated at the human elbow joint in response to constant position errors imposed during voluntary movements.

The stiffness of the human elbow joint was investigated during targeted, 1.0-rad voluntary flexion movements at speeds ranging from slow (1.5 rad/s) to very fast (6.0 rad/s). A torque motor produced controlled step position errors in the execution of the movements. The steps began at the onset of movement, rose to an amplitude of 0.15 rad in 100 ms, and had a duration equal to movement duration. The net joint torque (muscle torque) resisting the step perturbation was computed from the applied torque, the joint acceleration, and the limb inertia. Subjects resisted the imposed step changes with approximately step changes in the net muscle torque. The mean resistance torque divided by the step amplitude was computed and is referred to as the stiffness. The stiffness increased with the voluntary movement speed, over the range of speeds (1.5-6 rad/s). The stiffness increased linearly with the magnitude of the net muscle torque on the unperturbed trials (referred to as "background torque"). The stiffness changed by only 20% when the step amplitude ranged from 0.05 to 0.15 rad. The mechanical resonant frequency (fr), estimated from the average stiffness estimates, ranged from 0.8 to 3.0 Hz. The resonant frequency approximately equaled the principal frequency component of the movement fm. On average: fr = 0.96 fm +0.46. During the fixed, 100-ms rise time of the step, the resistance was not linearly related to the background torque. At slower speeds the resistance was relatively greater during this rise time. However, when the imposed step perturbation was modified so that its rise time occurred in a time proportional to the movement duration (rather than in the fixed, 100-ms, time), the muscle torque resisting the motor during this rise time was proportional to the background torque. When these modified step responses were plotted on a time scale normalized to the movement duration, they all had approximately the same shape. Apparently the muscle viscosity scaled with the stiffness so as to maintain the constant response shape (constant damping ratio). The observed "tuning" of the mechanical properties to the movement speed is suggested to be important in the robust generation of smooth stereotyped voluntary movements.

Adult↗

Static firing rates of premotor and primary motor cortical neurons associated with torque and joint position.

Single cell activity was studied in the postarcuate premotor area (PMA) and primary motor cortex (MI) of two monkeys performing a load-bearing task with the contralateral hand. Steady-state discharge rates were examined in relation to positional maintenance of the wrist which was held in one of three given positions against graded torques directed towards flexion or extension. Significant and monotonic relationships between tonic firing rate and static torque were found in 41% of 477 MI cells and in only 26% of 470 units studied in PMA. However, for specific cell groups in the PMA the proportion of load-related neurons reached that of the MI samples; this was true for pyramidal tract neurons (PTNs) and for 'non-PTNs' if recorded in their vicinity. The most interesting difference pertains to the range of load over which cells in both areas modulated activity. MI neurons showed steepest change of firing rates over a limited range of small torques around zero external load; the population average displayed a sigmoidal relationship. Proportionally more PMA neurons increased their activity over the entire range of torques examined or showed the highest increase with stronger torques; the population average best fitted a quadratic function. The mean firing rate-torque slope of the PMA population was significantly smaller than that of MI. Many cells in either area were related to both torque and joint position and displayed correlates of length-tension properties of muscle. Change of position sensitivity with torque was found to parallel the rate-torque characteristics in individual neurons. Mean position sensitivity of PMA neurons increased with increasing torques in the 'preferred' direction. In contrast, greatest position sensitivity of the MI population occurred over the range of low torques, which means a clear quantitative dissociation from the muscular activities. The results suggest differential roles of MI and PMA in the control of 'fine' versus 'gross' muscular forces. Undoubtedly, some PMA cell elements (possibly certain output neurons) are involved in aspects of postural control of EMG adjustment to load and joint position.

Animals↗

Reprogramming of muscle activation patterns at the wrist in compensation for elbow reaction torques during planar two-joint arm movements.

The relationship between wrist kinematics, dynamics and the pattern of muscle activation were examined during a two-joint planar movement in which the two joints moved in opposite directions, i.e. elbow flexion/wrist extension and elbow extension/wrist flexion. Elbow movements (ranging from 10 to 70 deg) and wrist movements (ranging from 10 to 50 deg) were performed during a visual, step-tracking task in which subjects were required to attend to the initial and final angles at each joint. As the elbow amplitude increased, wrist movement duration increased and the wrist movement trajectories became quite variable. Analysis of the torques acting at the wrist joint showed that elbow movements produced reaction torques acting in the same direction as the intended wrist movement. Distinct patterns of muscle activation were observed at the wrist joint that were dependent on the relative magnitude of the elbow reaction torque in relation to the net wrist torque. When the magnitude of the elbow reaction torque was quite small, the wrist agonist was activated first. As the magnitude of the elbow reaction torque increased, activity in the wrist agonist decreased significantly. In conditions where the elbow reaction torque was much larger than the net wrist torque, the wrist muscle torque reversed direction to oppose the intended movement. This reversal of wrist muscle torque was directly associated with a change in the pattern of muscle activation where the wrist antagonist was activated prior to the wrist agonist. Our findings indicate that motion of the elbow joint is an important consideration in planning wrist movement. Specifically, the selection of muscle activation patterns at the wrist is dependent on the relative magnitude and direction of the elbow reaction torque in relation to the direction of wrist motion.

Animals↗

A new non-orthogonal decomposition method to determine effective torques for three-dimensional joint rotation.

This paper describes a new non-orthogonal decomposition method to determine effective torques for three-dimensional (3D) joint rotation. A rotation about a joint coordinate axis (e.g. shoulder internal/external rotation) cannot be explained only by the torque about the joint coordinate axis because the joint coordinate axes usually deviate from the principal axes of inertia of the entire kinematic chain distal to the joint. Instead of decomposing torques into three orthogonal joint coordinate axes, our new method decomposes torques into three "non-orthogonal effective axes" that are determined in such a way that a torque about each effective axis produces a joint rotation only about one of the joint coordinate axes. To demonstrate the validity of this new method, a simple internal/external rotation of the upper arm with the elbow flexed at 90 degrees was analyzed by both orthogonal and non-orthogonal decomposition methods. The results showed that only the non-orthogonal decomposition method could explain the cause-effect mechanism whereby three angular accelerations at the shoulder joint are produced by the gravity torque, resultant joint torque, and interaction torque. The proposed method would be helpful for biomechanics and motor control researchers to investigate the manner in which the central nervous system coordinates the gravity torque, resultant joint torque, and interaction torque to control 3D joint rotations.

Arm↗

Torque generated by the flagellar motor of Escherichia coli.

Cells of the bacterium Escherichia coli were tethered and spun in a high-frequency rotating electric field at a series of discrete field strengths. This was done first at low field strengths, then at field strengths generating speeds high enough to disrupt motor function, and finally at low field strengths. Comparison of the initial and final speed versus applied-torque plots yielded relative motor torque. For backward rotation, motor torque rose steeply at speeds close to zero, peaking, on average, at about 2.2 times the stall torque. For forward rotation, motor torque remained approximately constant up to speeds of about 60% of the zero-torque speed. Then the torque dropped linearly with speed, crossed zero, and reached a minimum, on average, at about -1.7 times the stall torque. The zero-torque speed increased with temperature (about 90 Hz at 11 degrees C, 140 Hz at 16 degrees C, and 290 Hz at 23 degrees C), while other parameters remained approximately constant. Sometimes the motor slipped at either extreme (delivered constant torque over a range of speeds), but eventually it broke. Similar results were obtained whether motors broke catastrophically (suddenly and completely) or progressively or were de-energized by brief treatment with an uncoupler. These results are consistent with a tightly coupled ratchet mechanism, provided that elastic deformation of force-generating elements is limited by a stop and that mechanical components yield at high applied torques.

Biomechanical Phenomena↗

Mechanisms controlling accurate changes in elbow torque in humans.

This paper addresses a fundamental question of how motor commands specify target torque levels. Human subjects produced fast and accurate changes in torque with the isometric elbow joint. Visual stimuli were used to indicate target torque levels as well as to cue subjects to initiate their responses. During rapid changes in torque from one steady-state level to another, target torque was achieved through a sequence of approximations. During the first 200-250 msec of responses produced in the presence of visual feedback, 3 distinct control mechanisms were recruited to guide torque to the target level. The timing and accuracy of each control mechanism were evaluated. The first control mechanism was triggered by the visual stimulus and produced the initial rise in torque. Target torque predictability was found to strongly influence the accuracy of this control mechanism. The second control mechanism produced a corrective adjustment in torque within roughly the first 100 msec of responses. This mechanism incorporated target torque information provided by the stimulus into the response. The third control mechanism began 200-250 msec after response onset and produced corrective adjustments based on visual feedback of torque errors. The stability of the visual feedback mechanism was evaluated because of a long loop delay. Two strategies were used to control stability: low gain and information transfer between the visual feedback mechanism and the preceding (second) control mechanism.

Adult↗

The effect of time to peak ankle torque on balance stability boundary: experimental validation of a biomechanical model.

Pai and Patton (1997), using a biomechanical model, determined a set of feasible center of mass (CM) velocity-position combinations (balance stability boundary) that guarantee upright stability. In their study, the magnitude of the restoring ankle torque was used to study the subject's ability to recover balance. Recent studies have suggested that the ability to maintain a stable posture depends not only on the magnitude of the restoring torque but also on the time to generate this torque. The objectives of the present study were: (1) to build a biomechanical model that predicts the balance stability boundary which includes time to peak ankle torque, (2) to determine the capability of the model to predict successful and failed experimental balance recovery trials, and (3) to compare the predictive capability of the biomechanical model with that of a statistical model (logistic regression). A single-link-plus-foot biomechanical model was used to determine a set of balance stability boundaries, computed from the combination of maximum CM velocity and related CM position, for various times to peak ankle torque. An experiment was conducted to validate the biomechanical model. The participants self-initiated a forward destabilization and were asked to regain balance using an ankle feet-in-place strategy. Also, a forward stepwise logistic regression (predictors: CM position and velocity and time to peak ankle torque) was used to discriminate between successful and failed experimental trials. (1) The outcomes of the biomechanical model confirmed that the time to peak ankle torque drastically constrained the stability boundaries. (2) The biomechanical model predicted 79.9% of the failed experimental trials and 74.5% of the successful experimental trials. (3) The stepwise logistic regression included all independent variables and predicted 57.2% of the failed and 93.7% of the successful experimental trials. Hence, the biomechanical model showed better predictive capability than the statistical model for identifying unsuccessful balance recovery. It is noteworthy that the balance stability boundaries constrained by the speed of ankle torque development predicted the outcome of the experimental trial earlier in the time series than balance stability boundary constrained by constant ankle torque. Overall, the present biomechanical model may serve as an assessment tool to develop specific interventions towards improving a patient's speed of ankle torque development and to possibly reduce falling frequency.

Accidental Falls↗

Mechanical testing of small fracture implants for comparison of insertion and failure torques.

INTRODUCTION: Small fracture screws are among the most commonly used implants in the field of orthopedic surgery. The goal of this study was to compare the insertion and failure torques of three screw types: cortical, partially threaded cancellous, and fully threaded cancellous from three manufacturers: Zimmer, Richards, and Synthes. MATERIALS AND METHODS: Each type of screw was subjected to biomechanical tests to determine the insertion ( n=6/group) and failure ( n=10/group) torques. RESULTS: Two-factor ANOVA tests were run to determine whether the insertion or failure torques were different for the different screw types and manufacturers. In the case of insertion torques, neither the screw nor the manufacturer had any significant effect. In the case of failure torque, significant differences were found based on both the screw type and the manufacturer, with the cortical screws manufactured by Zimmer being the strongest. Although there were strength differences, the most important comparison clinically is between the failure torque and the insertion torque of each screw. In all cases, the failure torques were approximately 20 times larger than the insertion torques, and therefore no failures should occur if only torsional loads are applied during insertion. This comparison shows that factors other than screw strength and manufacturing processes may be involved in cases of screw failure during insertion. CONCLUSION: All three screw types from all three manufacturers appear to be mechanically reliable, with the proper insertion to failure torque ratio. The surgeon's choice of implant should be based on other considerations.

Analysis of Variance↗

Mechanical torque measurement predicts load to implant cut-out: a biomechanical study investigating DHS anchorage in femoral heads.

INTRODUCTION: Bone strength plays an important role in implant anchorage. Bone mineral density (BMD) is used as surrogate parameter to quantify bone strength and to predict implant anchorage. BMD can be measured by means of quantitative computer tomography (QCT) or dual energy X-ray absorptiometry (DXA). These noninvasive methods for BMD measurement are not available pre- or intra-operatively. Instead, the surgeon could determine bone strength by direct mechanical measurement. We have evaluated mechanical torque measurement for (A) its capability to quantify local bone strength and (B) its predictive value towards load at implant cut-out. MATERIALS AND METHODS: Our experimental study was performed using sixteen paired human cadaver proximal femurs. BMD was determined for all specimens by QCT. The torque to breakaway of the cancellous bone structure (peak torque) was measured by means of a mechanical probe at the exact position of subsequent DHS placement. The fixation strength of the DHS achieved was assessed by cyclic loading in a stepwise protocol beginning with 1,500 N increasing 500 N every 5,000 cycles until 4,000 N. RESULTS: A highly significant correlation of peak torque with BMD (QCT) was found (r = 0.902, r (2) = 0.814, P < 0.001). Peak torque correlated highly significant with the load at implant cut-out (r = 0.795, P < 0.001). All specimens with a measured peak torque below 6.79 Nm failed at the first load level of 1,500 N. The specimens with a peak torque above 8.63 Nm survived until the last load level of 4,000 N. CONCLUSION: Mechanical peak torque measurement is able to quantify bone strength. In an experimental setup, peak torque identifies those specimens that are likely to fail at low load. In clinical routine, implant migration and cut-out depend on several parameters, which are difficult to control, such as fracture type, fracture reduction achieved, and implant position. The predictive value of peak torque towards cut-out in a clinical set-up therefore has to be carefully validated.

Aged↗