Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “TOMOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Contribution of conventional axial computed tomography (nonhelical), in conjunction with panoramic tomography (zonography), in evaluating mandibular fractures.

Previous studies comparing the sensitivity between different radiological exams have concluded that conventional axial computed tomography (CT; nonhelical) is unsuitable in the assessment of mandibular fractures. Axial CT was shown to have a reduced sensitivity compared with plain radiographs and panoramic tomography because it missed nondisplaced fractures in the posterior portion of the mandible. Because the resolution of CT has improved from the time of these previous studies, the authors were interested in assessing whether axial CT (nonhelical) could now provide additional clinically useful information and enhance our understanding of mandibular fractures, beyond that obtained from panoramic tomography alone. In their study, 5 staff surgeons initially evaluated the panoramic tomograms and then the CT scans of 39 patients with 66 fractures. A series of four questions assessed the relative contribution of these two radiological exams in formulating an optimal operative plan for each patient. The authors found that axial CT provided supplementary information regarding missed fractures, comminution, and the exact size and degree of displacement of fracture fragments. This additional data could have changed the operative plan in a substantial proportion of patients (17 of 39). Axial CT demonstrated two missed parasymphyseal fractures (2 of 39 patients) that were not seen on these patients' panoramic tomograms. Axial CT also revealed undiscovered comminution or demonstrated fracture displacement more precisely in 39% of patients (15 of 39) and 24% of fractures (16 of 66). This study demonstrates that axial CT was clinically useful as an additional investigation to panoramic tomography. Axial CT helped elucidate further the nature of suspected mandibular fractures.

Humans↗

Fractional quantitative computed tomography for bone mineral density evaluation: accuracy, precision, and comparison to quantitative computed tomography.

OBJECTIVE: To evaluate bone mineral density considering its distribution, fractional quantitative computed tomography (fQCT) was designed and verified. METHODS: Quantitative computed tomography (QCT) was performed at 64 areas in 10 swine long bones. Fractional quantitative computed tomography was measured at the identical areas as the proportion of pixels showing a bone density higher than 130 mg/mL equivalent. All target areas were extracted and incinerated to measure apparent ash bone density. Based on standard references, the accuracy and precision of fQCT were evaluated and the results were compared with conventional QCT results. RESULTS: The correlation coefficient between fQCT and apparent ash bone density was 0.843 (P < 0.0001). The fQCT showed good correlation with volume fraction (r = 0.88, P < 0.0001). The coefficient of variation of fQCT was 0.42%. The fQCT revealed higher accuracy and precision than the results of QCT. CONCLUSION: Fractional quantitative computed tomography was designed and verified as a reliable method to measure bone mineral density.

Animals↗

Two-year outcomes of computed tomography-based and computed tomography free navigation for total knee arthroplasties.

UNLABELLED: Optimal component position in all planes and well-balanced soft tissues facilitate a good clinical outcome and long-term survival after total knee arthroplasties. We investigated the accuracy of implantation of navigated total knee arthroplasties at 3 months followup and the influence on the clinical outcome at 2 years followup. Forty-four patients (44 procedures) were enrolled in our prospective study. One half of the surgeries were performed using a computed tomography-based navigation system, and half were performed with imageless navigation. Outcomes were based on the Insall knee score parameters, anterior knee pain, patient satisfaction, feeling of instability, and step test. The radiographic parameters were the mechanical axis, tibial slope, lateral distal femoral angle, and medial proximal tibial angle. The radiographic measurements were similar in both groups (patients within +/- 3 degrees inaccuracy range in computed tomography-based/imageless groups; mechanical axis 86%/81%, tibial slope 95%/91%, lateral distal femoral angle 95%/91%, medial proximal tibial angle 91%/95%). The imageless system provided equal radiographic results, but we found improved ligament balancing in the computed tomography free group. The computed tomography-based approach has a good pre-operative planning procedure, but is more expensive and time consuming. LEVEL OF EVIDENCE: Therapeutic Study, Level II. See the Guidelines for Authors for a complete description of levels of evidence.

Aged↗

Ultrasound-mediated biophotonic imaging: a review of acousto-optical tomography and photo-acoustic tomography.

This article reviews two types of ultrasound-mediated biophotonic imaging-acousto-optical tomography (AOT, also called ultrasound-modulated optical tomography) and photo-acoustic tomography (PAT, also called opto-acoustic or thermo-acoustic tomography)-both of which are based on non-ionizing optical and ultrasonic waves. The goal of these technologies is to combine the contrast advantage of the optical properties and the resolution advantage of ultrasound. In these two technologies, the imaging contrast is based primarily on the optical properties of biological tissues, and the imaging resolution is based primarily on the ultrasonic waves that either are provided externally or produced internally, within the biological tissues. In fact, ultrasonic mediation overcomes both the resolution disadvantage of pure optical imaging in thick tissues and the contrast and speckle disadvantages of pure ultrasonic imaging. In our discussion of AOT, the relationship between modulation depth and acoustic amplitude is clarified. Potential clinical applications of ultrasound-mediated biophotonic imaging include early cancer detection, functional imaging, and molecular imaging.

Acoustics↗

Airway dimensions measured from micro-computed tomography and high-resolution computed tomography.

Volume averaging results in both over- and underestimation of airway dimensions when they are measured by high-resolution computed tomography (HRCT). The current authors calibrated computerised measurements of airway dimensions from HRCT against a novel three-dimensional micro-computed tomography (CT) standard, which has a 50-fold greater resolution, as well as against traditional morphometry. Inflation-fixed porcine lung cubes were scanned by HRCT and micro-CT. A total of 59 lumen area (Ai), 30 wall area (A(aw)) and 11 lumen volume (Vi) measurements were made. Ai was measured from the cut surface of 11 airways by morphometry. Airways in scanned images were matched using branching points. After calibration, the errors of Ai, A(aw) and Vi HRCT measurements were determined. The current authors found a systematic, size-dependent underestimation of Ai and overestimation of A(aw) from HRCT measurements. This was used to calibrate an HRCT measurement algorithm. The 95% limits of agreement of subsequent measurements were +/-3.2 mm2 for Ai, +/-4.3 mm2 for A(aw), and +/-11.2 mm3 for Vi with no systematic error. Morphometric measurements agreed with micro-CT (+/-2.5 mm2) without systematic error. In conclusion, micro-computed tomography image data from inflation-fixed airways can be used as calibration standards for three-dimensional lumen volume measurements from high-resolution computed tomography, while morphometry is acceptable for two-dimensional measurements. The image dataset could be used to validate other developmental three-dimensional segmentation algorithms.

Animals↗

[Comparison of scanning laser polarimetry, optical coherence tomography 1 and Stratus optical coherence tomography for the detection of axonal loss in band atrophy of the optic nerve].

PURPOSE: To compare the abilitiy of scanning laser polarimetry (GDx), optical coherence tomography (OCT) 1 and Stratus- optical coherence tomography to discriminate between healthy eyes and eyes with band atrophy of the optic nerve and temporal hemianopsia. METHODS: Twenty-three eyes with band atrophy of the optic nerve and 23 eyes from healthy subjects were included in this observational prospective case-control study. All eyes underwent retinal nerve fiber layer (RNFL) thickness analysis using GDx, optical coherence tomography-1 and Stratus-optical coherence tomography. Mean values obtained with each equipment were compared between band atrophy and normal eyes. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% e 95%) were calculated for each parameter calculated with each equipment and compared. RESULTS: When compared with healthy subjects, the parameters corresponding to the global average as well as each of the four quadrant retinal nerve fiber layer thickness in eyes with band atrophy were significantly smaller (p<0.05), than in normal eyes, with the exception of GDx's temporal thickness parameter. Comparison of the areas under ROC curves (AUCs) of the parameters from the three equipments revealed significantly greater values for the Stratus-OCT when compared to the OCT-1 in the global average and in the temporal quadrant thickness measurement. Stratus-OCT was significantly more sensitive than GDx in the global average as well as in the temporal, nasal and inferior quadrant. OCT-1 was superior to GDx only in the temporal quadrant. All three equipments revealed a similar ability to identify retinal nerve fiber layer reduction in the superior quadrant. CONCLUSIONS: The Stratus OCT showed the best ability to discriminate between eyes with band atrophy of the optic nerve and healthy eyes although all three equipments were able do identify most of the abnormal eyes. OCT-1 was inferior to Stratus-OCT and superior do GDx in the temporal quadrant. Although GDx was able identify some abnormality in most studied eyes, the equipment showed poor sensitivity in the detection of axonal loss in the nasal and temporal aspect of the optic disc and should be used with caution in neuro-ophthalmic diseases that cause retinal nerve fiber layer loss in those areas of the optic disc.

Axons↗

Osseous temporomandibular joint abnormalities in rheumatic disease. Computed tomography versus hypocycloidal tomography.

Computed tomography (CT) of the temporomandibular joint (TMJ) was compared with hypocycloidal tomography in 30 joints of 15 adults with rheumatic disease. CT included 1.5 mm thick axial scans (at 1.0 mm intervals) with reformatted oblique sagittal and oblique coronal sections. Multisection (at 2.0 mm intervals) tomography included oblique sagittal and occasionally, oblique coronal sections. CT demonstrated bone abnormalities in 21 and tomography in 20 joints, indicating high agreement between the imaging modalities regarding number of abnormal TMJs. Bone structures were, however, better visualized by multiplanar CT due to superior contrast and spatial resolution particularly in the most lateral and medial parts of the joint, indicating superiority of CT for depicting subtle bony TMJ abnormalities in patients with rheumatic disease.

Adolescent↗

Quantitative positron emission tomography and single photon emission computed tomography measurements of human cerebral blood flow.

Current methods using emission tomography to quantitate human regional cerebral blood flow (rCBF) are reviewed. The sensitivity and spatial resolution of single photon emission tomography are too low to correlate reliably rCBF with known anatomic landmarks in the brain. However, even if the superior imaging qualities of positron emission tomography are employed, the radiotracers of rCBF frequently do not fully meet the requirements of the models of tracer kinetics that are employed. Therefore, the methodology of reported rCBF studies using emission tomography to measure quantitatively human rCBF needs to be carefully evaluated.

Brain↗

A study of computer-assisted tomography. II. Comparison of metrizamide myelography and computed tomography in the diagnosis of herniated lumbar disc and spinal stenosis.

One hundred twenty-two patients with surgically confirmed pathology consisting of either herniated lumbar disc, spinal stenosis, or both were included in this investigation. For each of these patients, preoperative metrizamide myelography and computerized tomography were performed. Each myelogram and CT scan was read blindly so that the neuroradiologist interpreting the study had no knowledge of the patient's surgical pathology, clinical examination, nor any knowledge of the interpretation of the other preoperative test. A painstaking attempt was made to describe precisely both the exact nature of the preoperative myelogram and CT scan interpretations. The correlations between the preoperative interpretation of each test and the observed surgical findings then were analyzed statistically. Based upon this analysis, myelography was found to be more accurate than computed tomography in the diagnosis of herniated lumbar disc (83% vs. 72%). In the diagnosis of spinal stenosis, myelography was slightly more accurate than computed tomography (93% vs. 89%). Based upon the results of this study, the authors conclude that metrizamide myelography is more accurate than computed tomography in the diagnosis of both herniated lumbar disc and spinal stenosis and remains the diagnostic study of choice for these conditions. Furthermore, metrizamide myelography gives the added advantage of visualizing the thoracolumbar junction and, thus, affords the opportunity to diagnose occult spinal tumors.

False Negative Reactions↗

Diagnosis and staging of head and neck cancer: a comparison of modern imaging modalities (positron emission tomography, computed tomography, color-coded duplex sonography) with panendoscopic and histopathologic findings.

OBJECTIVE: To compare the clinical value of positron emission tomography (PET) using fludeoxyglucose F 18, computed tomography (CT), color-coded duplex sonography (CCDS), and panendoscopy in the detection and staging of head and neck cancer. DESIGN: Prospective nonrandomized controlled study. SETTING: Medical school. PATIENTS: Convenience sample of 50 patients with suspected primary or recurrent head and neck cancer. INTERVENTION: Biopsy, tumor surgery. MAIN OUTCOME MEASURES: Information of diagnostic procedures compared with histopathologic features. RESULTS: Both PET and panendoscopy had a sensitivity of 95% and 100% for detection of primary tumor or recurrent carcinomas, respectively. Specificity for PET and panendoscopy was 92% and 85% in primary tumors and 100% and 80% in recurrent carcinoma, respectively. Sensitivity of CCDS and CT was 74% and 68% in primary tumors and 67% and 63% in recurrent carcinomas, respectively. Specificity was 75% and 69% in primary tumors and 100% and 80% in recurrent neoplasms. When assessing neck nodes, all imaging procedures exhibited identical sensitivity (84%). Specificity was 90%, 96%, and 88% in PET, CT, and CCDS, respectively. In recurrent lymph node metastases, sensitivity was 100%, 67%, and 67% and specificity was 87%, 91%, and 87% for PET, CT, and CCDS, respectively. CONCLUSIONS: Positron emission tomography was the most reliable imaging procedure in the detection of primary tumor and recurrent carcinomas localized in the head and neck region. Owing to its limited anatomical depiction, it cannot as yet replace other diagnostic procedures in preoperative planning but does contribute valuable complementary diagnostic information. Computed tomograpy may have difficulties in identifying recurrent carcinomas. For routine diagnosis of nodal spread in the neck, CCDS is recommended. Panendoscopy is a valuable diagnostic procedure that can provide key information in cases of superficial mucosal tumor involvement. Arch Otolaryngol Head Neck Surg. 2000;126:1457-1461

Biopsy↗

Cardiac metabolism: a technical spectrum of modalities including positron emission tomography, single-photon emission computed tomography, and magnetic resonance spectroscopy.

Noninvasive techniques for the assessment of cardiac metabolism are important for the detection of potentially salvageable tissue in jeopardized areas of the myocardium. The correct identification of hibernating and stunned myocardium in patients with severely depressed cardiac function can have vital therapeutic consequences for the patient. Changes in myocardial fatty acid and glucose metabolism during acute and prolonged ischemia can be traced by positron-emitting or gamma-emitting radiopharmaceuticals. Alternatively, 31P-labeled magnetic resonance spectroscopy can be used for the assessment of high-energy phosphate metabolism. It is not yet clear which modality will emerge as the most useful in the clinical setting. Positron emission tomography (PET) that uses combinations of flow tracers and metabolic tracers offers unique opportunities for quantification and high-resolution static and rapid dynamic studies. Currently, assessment of glucose metabolism with 18F-fluorodeoxyglucose is regarded as the gold standard for myocardial viability and prediction of improvement of impaired contractile function after revascularization. However, preserved oxidative metabolism may be required for potential functional improvement, and therefore assessment of residual oxidative metabolism by 11C-labeled acetate PET may prove to be more accurate than 18F-fluorodeoxyglucose PET, which reflects both anaerobic and oxidative metabolism. Moreover, because fatty acids are metabolized only aerobically, they are excellent candidates for the clinical assessment of myocardial viability and prediction of functional improvement after revascularization. Especially derivatives of fatty acids that are not metabolized but accumulate in the myocyte are attractive for myocardial imaging. Examples are 123I-beta-methyl-p-iodophenyl pentadecanoic acid and 15-(o-123I-phenyl)-pentadecanoic acid. These tracers can be detected by planar scintigraphy and single-photon emission computed tomography, which are more economical and widely available than PET. In addition, 511 keV collimators have been developed recently, making the detection of positron emitters by planar scintigraphy and single-photon emission computed tomography feasible. The experience with 31P-labeled magnetic resonance spectroscopy in humans is still limited. With current magnetic resonance spectroscopic techniques, insufficient spatial resolution is achieved for clinical purposes, but the possibility of serial measurements to monitor rapid changes of phosphate-containing molecules in time makes magnetic resonance spectroscopy very valuable for the research of myocardial metabolism.

Acetic Acid↗

A novel phantom design for emission tomography enabling scatter- and attenuation-"free" single-photon emission tomography imaging.

A newly designed technique for experimental single-photon emission tomography (SPET) and positron emission tomography (PET) data acquisition with minor disturbing effects from scatter and attenuation has been developed. In principle, the method is based on discrete sampling of the radioactivity distribution in 3D objects by means of equidistant 2D planes. The starting point is a set of digitised 2D sections representing the radioactivity distribution of the 3D object. Having a radioactivity-related grey scale, the 2D images are printed on paper sheets using radioactive ink. The radioactive sheets can be shaped to the outline of the object and stacked into a 3D structure with air or some arbitrary dense material in between. For this work, equidistantly spaced transverse images of a uniform cylindrical phantom and of the digitised Hoffman rCBF phantom were selected and printed out on paper sheets. The uniform radioactivity sheets were imaged on the surface of a low-energy ultra-high-resolution collimator (4 mm full-width at half-maximum) of a three-headed SPET camera. The reproducibility was 0.7% and the uniformity was 1.2%. Each rCBF sheet, containing between 8.3 and 80 MBq of 99mTcO4- depending on size, was first imaged on the collimator and then stacked into a 3D structure with constant 12 mm air spacing between the slices. SPET was performed with the sheets perpendicular to the central axis of the camera. The total weight of the stacked rCBF phantom in air was 63 g, giving a scatter contribution comparable to that of a point source in air. The overall attenuation losses were <20%. A second SPET study was performed with 12-mm polystyrene plates in between the radioactive sheets. With polystyrene plates, the total phantom weight was 2300 g, giving a scatter and attenuation magnitude similar to that of a patient study. With the proposed technique, it is possible to obtain "ideal" experimental images (essentially built up by primary photons) for comparison with "real" images degraded by photon scattering and attenuation losses. The method can serve as a tool for experimental validation and intercomparison of attenuation and scatter correction methods. Moreover, the large flexibility of this phantom design will allow investigations of arbitrary activity distributions and autoradiography or other imaging techniques such as PET, x-ray computed tomography or magnetic resonance imaging.

Brain↗

Clinical value of combined positron emission tomography/computed tomography imaging in the interpretation of 2-deoxy-2-[F-18]fluoro-D-glucose-positron emission tomography studies in cancer patients.

BACKGROUND: Positron emission tomography (PET)/computed tomography (CT) is a new imaging modality that provides exact coregistration of anatomic and metabolic data. We have investigated to what degree this new technique might affect the interpretation of PET images in a nonselected group of consecutive cancer patients, reflecting routine condition in a busy cancer center. METHODS: Whole-body 2-deoxy-2-[F-18]fluoro-D-glucose (FDG)-PET and PET/CT fusion image sets were compared in 100 consecutive, nonselected patients: 21 with head and neck cancer, 39 with chest malignancies, and 40 with malignancies of the abdomen and pelvis. All studies were performed for primary staging or evaluation of therapy and were interpreted by two nuclear medicine physicians also trained in radiology. Areas of abnormal FDG uptake were identified on PET and graded as likely benign, equivocal, or likely malignant. Positron emission tomography/computed tomography fusion images were then made available, and the initial findings were amended if necessary. RESULTS: One hundred sixty-six areas with abnormal FDG uptake were identified. Based on PET alone, 51 sites were considered equivocal for malignancy. With PET/CT, the number of equivocal lesions decreased to 24. This difference is more marked in the head and neck as well as the abdomen and pelvis. When the equivocal sites were included in the analysis and grouped with the malignant sites, positive predictive value (PPV) of PET/CT was 89% compared with 75% for PET (p = 0.04). CONCLUSION: Combined PET/CT results in increased reader confidence and 53% fewer equivocal readings, as well as improved PPV compared with PET alone.

Adolescent↗

Studies of central nervous system disorders with single photon emission computed tomography and positron emission tomography: evolution over the past 2 decades.

Single photon emission computed tomography (SPECT) was introduced in the 1960s to detect breakdowns in the blood-brain barrier and was replaced by x-ray computed tomography in the mid-1970s. The development of the deoxyglucose (DG) technique to measure regional cerebral glucose metabolism by employing either autoradiography, using 14CDG, or positron emission tomography (PET), using 18FDG, added a major dimension to the investigation of brain function. In the late 1970s and early 1980s, the FDG-PET technique was widely used to examine a variety of neuropsychiatric disorders. It soon became apparent that functional imaging was more sensitive than anatomic imaging in detecting abnormalities of the brain related to aging, dementia, tumors, seizures, cerebral vascular accidents, and psychiatric problems. Because of its complexity and the cost involved, PET was used in a limited number of centers in the United States. However, the success of PET resulted in the resurgence of interest in SPECT as an alternative technology after almost a decade. This became possible because of the synthesis of iodine 123- and technetium 99m-labeled radiopharmaceuticals to determine regional cerebral blood flow. Since blood flow and metabolism are coupled in most pathological states, patterns of abnormality noted on SPECT were similar to those seen on PET in many disorders. Since the introduction of high resolution SPECT imaging instruments, the role of SPECT has been further enhanced. The successful synthesis of both positron and single emitting radioligands to image dopamine and other receptors has started a new era in neurosciences and will have a far-reaching impact on the day-to-day practice of neuropsychiatry.

Adult↗

Comparison of sestamibi single-photon emission computed tomography with positron emission tomography for estimating left ventricular myocardial viability.

Technetium-99m methoxyisobutyl isonitrile (technetium-99m sestamibi [MIBI]) is distributed in the myocardium according to blood flow. Reports comparing stress rest sestamibi protocols with reinjection thallium or resting fluorodeoxyglucose (FDG), or both, in patients with coronary artery disease have shown appreciable discordance regarding myocardial viability in these settings. We performed this analysis with regard to regional comparisons within discordant segments and made comparisons in a subset of patients who underwent revascularization. Thirty-seven patients with coronary artery disease had single-photon emission computed tomography MIBI, N-13 ammonia/18FDG positron emission tomography (PET), and radionuclide ventriculography performed at rest. One hundred two segments were viable and 29 were nonviable by both MIBI and FDG. The concordance was 71%. In MIBI nonviable/FDG viable segments, most of the discordance was in the inferior wall. In MIBI nonviable discordant segments, FDG accurately predicted an increase in percent regional ejection fraction (preoperative 36% [+/- 5 SE] to postoperative 48% [+/- 5.5 SE][p < 0.0006]). MIBI underestimates myocardial viability as assessed by PET. Seventy-one percent of myocardial segments were concordant by both quantitative sestamibi single-photon emission computed tomography and FDG PET. Discordance in MIBI nonviable segments was predominantly in the inferior wall. PET can be helpful in detecting myocardial viability in patients suspected of having had MIBI nonviability in the inferior wall.

Adult↗

Computed tomography and positron emission tomography in the pre-operative staging of oesophageal carcinoma.

UNLABELLED: Because patients with carcinoma of the oesophagus usually present with advanced disease and surgery has a high mortality with cure in less than 10% of patients, pre-operative staging to select appropriate patients is necessary. Computed tomography (CT) plays an important role in staging but has well recognized limitations. Positron emission tomography (PET) which provides physiological information may therefore be a better alternative. OBJECTIVE: To compare the findings of CT and positron emission tomography (PET) with 2-[18fluorine]-fluoro-2-deoxy-D-glucose (FDG) in the pre-operative staging of oesophageal carcinoma. MATERIALS AND METHODS: Twenty-five patients with biopsy proven oesophageal cancer had pre-operative staging using CT and FDG-PET. The studies were read independently and full histological confirmation was obtained in 19 patients. Four parameters were studied: the primary tumour, peri-oesophageal lymph nodes, liver metastases and left gastric lymph nodes. RESULTS: PET visualized all primary tumours; CT missed one. CT identified 4/8 patients with involved peri-oesophageal nodes and PET 3/8. CT identified 5/9 patients with left gastric adenopathy and PET 1/9. PET visualized a liver metastasis missed on CT and appeared to be better in assessing residual tumour. PET did identify distant metastases not seen on CT in seven patients. CONCLUSIONS: The two techniques are both effective in showing the primary tumour and about equally sensitive in the demonstration of peri-oesophageal nodes. PET is probably more sensitive than CT for the detection of distant metastases.

Esophageal Neoplasms↗

Calibration of trabecular bone structure measurements of in vivo three-dimensional peripheral quantitative computed tomography with 28-microm-resolution microcomputed tomography.

It has recently been shown that high-resolution computed tomography and magnetic resonance imaging have the potential to assess information about the microarchitecture of bone in a noninvasive way. However, due to the limited spatial resolution of the in vivo measurements, the individual trabeculae are not depicted with their true thickness. Nevertheless, the spacing of the structural elements allows the assessment of trabecular number. In a previous publication, the ridge number density (RND) was introduced as a measure for this structural index. It can be extracted from high-resolution three-dimensional (3D) images of patients and shows a reproducibility of 1.6%. In this work the Ridge extraction procedure is compared to and calibrated with microcomputed tomography (microCT) measurements. Three-dimensional measurements of 15 bone biopsies are made with a 28-microm-resolution microCT scanner as well as with a 165-microm-resolution peripheral quantitative computed tomography (pQCT) scanner. For the latter, the same settings are used as for patient examinations. The 15 pairs of measurements are analyzed and the resulting structural indices are compared. The results show that structural indices such as trabecular number, mean thickness, and mean separation can be determined from the 3D pQCT data with an r2 of between 0.81 and 0.96 if the microCT data are taken as the gold standard. The calibration equation found for the bone volume fraction has an intercept of 0.04 and a slope of 0.86 (r2 = 0.98), and trabecular number as the main additional structural index shows a nonsignificant intercept and a calibration slope of 0.91 with the microCT. The calibration procedure can be used directly for patient examinations. Applied to time-series measurements it may be of value for monitoring and quantifying microarchitectural changes due to therapy or aging.

Adult↗

Acetazolamide reactivity on 123I-IMP single photon emission computed tomography in patients with major cerebral artery occlusive disease: correlation with positron emission tomography parameters.

Single photon emission computed tomography (SPECT) with acetazolamide challenge has increasingly been used for evaluating hemodynamic reserve in stroke patients. The accuracy of this test, however, has not been validated with positron emission tomography (PET). In 14 patients who had occlusive disease of the internal carotid artery or the trunk of the middle cerebral artery (MCA) with minimal or no infarction on computed tomography (CT) and magnetic resonance imaging (MRI), we compared acetazolamide reactivity on SPECT with N-isopropyl-p-[123I]-iodoamphetamine to hemodynamic parameters determined with gas inhalation labeled 15O steady-state PET studies. The asymmetry index (AI)--i.e., the percentage of the activity rate of the ischemic MCA territory versus the contralateral one, was determined by SPECT. Acetazolamide reactivity expressed as delta AI, or change in AI after acetazolamide challenge, was significantly lower in seven patients than -8.4%, the lower limit of the 95% confidence interval for the normal reactivity. Values of ipsilateral CBF, cerebral blood volume (CBV)/CBF, and oxygen extraction fraction (OEF) and contralateral OEF were significantly different between patients with normal and reduced acetazolamide reactivity. Values of delta AI were correlated with OEF (r = -0.87; p < 0.001) and CBV/CBF (r = -0.56; p < 0.05). All patients with OEF > 0.52, the mean + 2 SD calculated from five normal volunteers, also had reduced acetazolamide reactivity, while the patients with normal OEF values had normal reactivity. The present study has demonstrated that SPECT studies with an acetazolamide challenge can detect the Stage II hemodynamic failure.

Acetazolamide↗