Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polyesters”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Degradation of natural and synthetic polyesters under anaerobic conditions.

Often, degradability under anaerobic conditions is desirable for plastics claimed to be biodegradable, e.g. in anaerobic biowaste treatment plants, landfills and in natural anaerobic sediments. The biodegradation of the natural polyesters poly(beta-hydroxybutyrate) (PHB), poly(beta-hydroxybutyrate-co-11.6%-beta-hydroxyvalerate) (PHBV) and the synthetic polyester poly(epsilon-caprolactone) (PCL) was studied in two anaerobic sludges and individual polyester degrading anaerobic strains were isolated, characterized and used for degradation experiments under controlled laboratory conditions. Incubation of PHB and PHBV films in two anaerobic sludges exhibited significant degradation in a time scale of 6-10 weeks monitored by weight loss and biogas formation. In contrast to aerobic conditions, PHB was degraded anaerobically more rapidly than the copolyester PHBV, when tested with either mixed cultures or a single strained isolate. PCL tends to degrade slower than the natural polyesters PHB and PHBV. Four PHB and PCL degrading isolates were taxonomically identified and are obviously new species belonging to the genus Clostridium group I. The depolymerizing enzyme systems of PHB and PCL degrading isolates are supposed to be different. Using one isolated strain in an optimized laboratory degradation test with PHB powder, the degradation time was drastically reduced compared to the degradation in sludges (2 days vs. 6-10 weeks).

Anaerobiosis↗

Biodegradation of polyesters containing aromatic constituents.

Polymers, which undergo a controlled biological degradation by micro-organisms came to remarkable interest during the last years. Composting for instance could so be established as an alternative waste management system for parts of the plastic waste. Within this group of innovative polymer, polyesters play a predominant role, due to their potentially hydrolyzable ester bonds. While aromatic polyesters such as poly(ethylene terephthalate) exhibit excellent material properties but proved to be almost resistant to microbial attack, many aliphatic polyesters turned out to be biodegradable but lack in properties, which are important for application. To combine good material properties with biodegradability, aliphatic-aromatic copolyesters have been developed as biodegradable polymers for many years. This article reviews the attempts to combine aromatic and aliphatic structures in biodegradable plastics and work, which has been done to evaluate the degradation behaviour and environmental safety of biodegradable polyesters, containing aromatic constituents.

Bacteria↗

Can knitting structure affect dilation of polyester bifurcated prostheses? A randomized study with the use of helical computed tomography scanning.

PURPOSE: The aim of this study was to prospectively evaluate the postoperative dilation of two types of knitted polyester arterial prostheses with the use of helical computed tomographic scanning. METHODS: Thirty-four patients who underwent aortoiliac or aortofemoral bifurcation grafting were randomized to receive a collagen-sealed warp-knitted polyester graft (n = 16 patients) or a gelatin-sealed Köper-knitted polyester graft (n = 18 patients). Alterations in size of all parts of the grafts were evaluated by helical computed tomographic scanning at postoperative day 8, at 3 months, and at 6 months. RESULTS: On postoperative day 8, the mean dilation of the Köper-knitted grafts was 18% +/- 8% for the stem and 15% +/- 12% for the limbs. At the same time period, the mean dilation of warp-knitted grafts was 27% +/- 13% for the stem and 33% +/- 18% for the limbs. No increase in graft dilation was observed at 3 and 6 months. Despite the wide range of values among patients with the same graft type, at each time interval, the Köper-knitted grafts dilated significantly less than the warp-knitted grafts (P <. 05). CONCLUSION: In this randomized study, helical computed tomographic scanning was an accurate technique with which to assess graft dilation. For a 6-month follow-up interval, the Köper-knitted polyester structure dilated less than the warp-knitted structure. Longer-term serial scans should allow a better understanding of the clinical significance of graft dilation.

Aged↗

Evaluation of a novel hirudin-coated polyester graft to physiologic flow conditions: hirudin bioavailability and thrombin uptake.

PURPOSE: Our laboratory has developed methods required to covalently bind recombinant hirudin (rHir) to the surface of polyester vascular grafts. Using alkaline hydrolysis of the polyester surface, carboxyl-binding sites are created on the outer periphery of each fiber. A series of static, in vitro experiments have demonstrated that surface-bound rHir rapidly removes and inhibits activated human alpha-thrombin from the reaction system; however, the performance of this modified graft material under physiologic flow conditions was undefined. METHODS: An in vitro flow loop was used to evaluate structural stability of the 125I-rHir and 131I-albumin covalently bound to the surface of 6 mm interior diameter crimped polyester grafts exposed to either constant flow (n = 4; shear rate, 300 sec(-1)) or pulsatile flow (n = 4; maximum shear rate, 780 sec(-1)) conditions for a 7-day period. In a separate series of experiments, the kinetics of thrombin-rHir interaction were evaluated through perfusion of 125I-rHir-coated grafts (n = 6) with 131I-thrombin for a 27-hour period under constant flow conditions. Identically prepared 125I-albumin-coated grafts (n = 3) were used as controls. RESULTS: Results of the stability experiments were independent of flow conditions, demonstrating moderate loss of both proteins, with rHir and albumin losses of 52.1% and 19.9% under constant flow and 49.1% and 21.6% under pulsatile flow, respectively. With results comparable with those of previous static experiments, rHir-coated grafts were significantly more effective at removing thrombin from the perfusion stream with 131I-thrombin binding densities of 3.08 +/- 0.61 and 0.64 +/- 0.04 NIHU/cm2 (p < 0.01) for rHir-coated and albumin-coated grafts, respectively. Estimates of the total amount of thrombin inactivated during the perfusion period similarly demonstrated a marked difference between the rHir-coated and control graft segments (125 +/- 8 vs. 3 +/- 14 NIHU; p < 0.005). CONCLUSIONS: These in vitro flow results illustrate that polyester grafts with covalently bound rHir can provide significant reductions in local thrombin concentration under physiologic flow conditions, and can serve as a foundation with which to understand the performance of these grafts when implanted in vivo under physiologic flow and shear rates.

Biocompatible Materials↗

Soluble camptothecin derivatives prepared by click cycloaddition chemistry on functional aliphatic polyesters.

Aliphatic polyesters are of interest as biomaterials and drug-delivery vehicles, as their ability to degrade under physiological conditions provides a mechanism for both drug release and clearance of the polymer from the body. Presented here is the synthesis of a polyester-drug graft copolymer conjugate, enabled by click cycloaddition of azide-functionalized camptothecin derivatives with alkyne-functionalized aliphatic polyesters. Further grafting of residual alkyne groups with azide-terminated poly(ethylene oxide) gave a water-soluble polyester-camptothecin conjugate. Control over PEGylation and drug loading, inherent to the graft copolymer design, opens versatile routes to new materials with potential utility in polymer therapeutics.

Azides↗

Water-soluble degradable hyperbranched polyesters: novel candidates for drug delivery?

A novel approach to hyperbranched polymers is presented in this work. Hyperbranched polyesters with a large amount of terminal hydroxyl groups are prepared by a one-pot synthesis from commercially available AB-type and CD(n)-type monomers (n >/= 2). In this paper, Michael addition of diethanolamine (CD(2)) or N-methyl-d-glucamine (CD(5)) to methyl acrylate (AB) generates dominantly AD(n)-type intermediates. Further self-condensation of intermediates at higher temperature and in the presence of catalyst gives hyperbranched polyesters. Because of the tertiary amino groups in the backbone and the hydroxyl groups in the linear and terminal units, the resulting hyperbranched polyester is highly soluble in water. Furthermore, the hyperbranched polymer is degradable because of its ester units. So, the water-soluble hyperbranched polyesters might be applied as a novel material for drug delivery.

Biodegradation, Environmental↗

Production of a polyester degrading extracellular hydrolase from Thermomonospora fusca.

The production of a polyester-degrading hydrolase from the thermophilic actinomycete Thermomonospora fusca was investigated with regard to its potential technical application. Only in the presence of a polyester (random aliphatic-aromatic copolyester from 1,4-butanediol, terephthalic acid, and adipic acid with around 40-50 mol % terephthalic acid in the acid component), the excretion of the extracellular enzyme could be achieved with an optimized synthetic medium using pectin and NH(4)Cl as nitrogen source. Compared to complex media, a significantly higher specific activity at comparable volumetric yields could be obtained, thus reducing the expenditure for purification. The activity profile in the medium is controlled by a complex process involving (1) induction of enzyme excretion, (2) enzyme adsorption on the hydrophobic polyester surface, (3) inhibition of enzyme generation by monomers produced by polyester cleavage, and (4) enzyme denaturation. Diafiltration with cellulose acetate membranes as the sole downstream processing step led to a product of high purity and with sufficient yield (60% of total activity). Scaling-up from shaking flasks to a fermentor scale of 100 L revealed no specific problems. However, the excretion of the hydrolase by the actinomycete turned out to be inhibited by the degradation products (monomers) of the aliphatic-aromatic copolyester used as inductor for the enzyme production. The crude enzyme exhibited generally similar properties (temperature and pH optimum) as the highly purified hydrolase described previously; however, the storage capability and thermal stability is improved when the crude enzyme solution is diafiltrated.

Actinomycetales↗

Polyester fibre prosthetic anterior cruciate ligament implant rupture: necrosis of ingrown connective tissue.

AIMS: To describe the histopathological and microanalytical features in seven cases of ruptured Apex(R) polyester (Terylene(R)) fibre anterior cruciate ligament prosthesis. METHODS AND RESULTS: Transmitted and polarized light microscopy was performed in all cases; one case was investigated by immunohistochemistry, transmission electron microscopy and scanning electron microscopy, with backscatter and X-ray detectors for elemental microanalysis. For comparison we also studied synovial biopsy material and unused polyester fibres. In the excised ligaments there was much ingrowth of fibrous tissue accompanying a florid giant cell reaction to the individual intact polyester fibres throughout the ligaments. Phagocytosis of particles of prosthesis-derived material was demonstrated and a striking finding was of necrosis of the ingrown connective tissue in the central portions of the ligaments. Hyalinized areas and 'neoligament growth' were less striking. A consistent finding in the polyester fibres was of small particles containing antimony, used as a catalyst in the manufacturing process. CONCLUSIONS: The pattern of reaction to the prosthetic material and the presence of necrosis differ from previous descriptions in animal and human explants of this and other prosthesis types. The mechanical effect of the necrosis is unlikely to be of significance with this ligament, which is load-bearing ab initio.

Adult↗

[Injury of polyester grafts by vascular clamps].

UNLABELLED: Protected vascular clamps are not new. Clamp associated damage of human arteries has already been published over 20 years ago. The necessity of protective clamps seems to have been forgotten. In our explant archive (230 explants) we have observed an accumulation of graft ruptures in the groin (13 of 25 ruptures). We presume a multifactorial process. Clamp damage could be part of it. The aim of this study is to prove the clamp induced damage of polyester vascular grafts and to examine whether protected clamps can reduce this. METHOD: Five unprotected (Aesculap(R) FB512R, FB502, FB517, Ulrich CC1235, CV3535) and 5 protected vascular clamp types (Aesculap(R) FB667, FB668, Edwards(R) - formally Baxter(R) - Fogarty(R) CV5050, CV5201, Edwards(R) Cosgrove(R) CV1033) were tested. A longitudinal burst test was performed after maximal clamp closure on 6 different, multifilament polyester yarns of 2 different vascular grafts manufacturers (B. Braun(R), Edwards(R)). RESULTS: The yarn tests with protected clamps showed no difference to those of the unclamped yarns. After clamping with unprotected vascular clamps the stress-strain-diagrams differed significantly. The mean, maximum burst strength was up to 75 % lower. Video documentation revealed filament ruptures. Damage of the yarn surface was seen on a simple woven graft in scanning electron microscopy (SEM). DISCUSSION: The application of unprotected vascular clamps on polyester vascular grafts is common in Germany (56 %). The observed damage of multifilament polyester yarns makes it necessary to re-consider the use of unprotected vascular clamps. The benefit for biological vessels has already been shown.

Blood Vessel Prosthesis↗

Longitudinal ruptures of polyester knitted vascular prostheses.

AIM: The purpose of the study was the characterization of a type of rupture occurring on warp-knitted polyester vascular prostheses. MATERIALS AND METHODS: We studied 20 cases of warp-knitted polyester vascular prostheses that were explanted from humans that showed a longitudinal rupture as a part of a collaborative retrieval program. All the prostheses were immediately fixed in a 10% formaldehyde solution after their explantation in the operating room. The clinical data of these cases were recorded. The explants were photographed, washed to eliminate the surrounding tissues, and photographed again. The ruptures were characterized with macroscopic examination, optical stereomicroscopy, and scanning electron microscopy. RESULTS: The mean duration of implantation of the prostheses was 16.0 +/- 3.3 years (range, 9-20.7 years). The prostheses were Cooley Double Velour (n = 15) and Microvel Double Velour (n = 5). There were 16 aortobifemoral bypass grafts, 1 aorto-biiliac, 1 aorto-aortic, 1 iliofemoral, and 1 axillobifemoral. The longitudinal ruptures occurred on two specific parts of the prostheses: the guide line (6 cases) and the remeshing line (11 cases). In three cases both lines were affected. Scanning electron microscopy showed major degradation of the trilobar filaments of the velour and gradual ruptures of the flat filaments of the remeshing and guide lines. CONCLUSIONS: In this study, we have identified a specific mechanism of late (9-20 years) longitudinal rupture of knitted polyester prostheses consisting of degradation of the polyester filaments along the remeshing and guide lines that run the length of the graft.

Aorta, Abdominal↗

Clearing and embedding in polyester resin for demonstrating the nerve distribution pattern of skeletal muscles.

The preservation of many stained gross specimens in solution creates some difficulties. It is convenient and effective to preserve material in polyester resin instead of glycerol. The aim of this study was to determine the usefulness of clearing and embedding using polyester resin. The samples consisted of the nerve distribution patterns of skeletal muscles stained using Sihler's method. The muscles were cleared more successfully and the intramuscular nerve distributions were demonstrated better in polyester than in glycerol. The method presented here eliminates not only the storage and handling problems of specimens, but also problems such as pale stains and the molding of preparations. Furthermore, it is more convenient to examine and to photograph specimens cleared and embedded in polyester than those stored in glycerol.

Glycerol↗

Exposure of orbital implants wrapped with polyester-urethane after enucleation for advanced retinoblastoma.

PURPOSE: Enucleation is the main form of treatment for advanced retinoblastoma. The major complication of this procedure is orbital implant exposure. Different implants and wrapping materials are currently in use. The aim of the current study was to analyze the complications associated with the use of polyester-urethane, an artificial dura substitute, as a wrapping material for enucleation in advanced retinoblastoma. METHODS: A retrospective review of 32 cases (28 patients), who were treated with enucleation for advanced retinoblastoma, was performed. The age of the patients ranged between 3 months and 6.7 years (median, 19 months). Additional chemotherapy was administered in 12 cases. The removed eyeball was replaced either with a silicone implant and polyester-urethane wrapping (13 cases) or hydroxyapatite, silicone-hydroxyapatite, or polyethylene implants without additional wrappings (19 cases). The follow-up period ranged from 7 months to 5.9 years (median, 22.4 months). Statistical analysis was performed using the Kaplan-Meier method. RESULTS: Single or multiple exposures occurred in 22% of cases (7/32). There were 6 exposures (46%, 6/13) in the group with polyester-urethane wrapping compared with only 1 exposure (5%, 1/19) in the implants without wrapping. This difference was statistically significant (p=0.0236). None of the other analyzed factors (additional chemotherapy, surgeon, age of the patient, or size of the implant) demonstrated a significant correlation to implant exposures. CONCLUSIONS: Wrapping of orbital implants with polyester-urethane resulted in a high rate of implant exposures after enucleation for advanced retinoblastoma. In this series, the best results were achieved with integrated implants without additional wrapping.

Child↗

Use of polyester filters for the preparation of leukocyte-poor platelet concentrates.

We studied the usefulness of two polyester leukocyte removal depth filters for the preparation of leukocyte-poor platelet concentrate. The Sepacell R500A removed approximately 92% of the white cells and 98% of the platelets from stored concentrate. In contrast, the Travenol 4C2423 polyester depth microaggregate filter removed less than 1% of the platelets but only 14% of the leukocytes. These findings were obtained with stored (5-day-old) random donor platelets as well as with 16-hour-old platelets collected by apheresis. We conclude that neither of these two leukocyte removal depth filters are suitable for the preparation of leukocyte-poor platelet concentrate; the Sepacell because it removes too many platelets and the 4C2423 because it removes too few leukocytes. The efficiency of cell removal by polyester filters is likely related to alteration of the polyester filter element during fiber manufacture.

Blood Platelets↗

Replacement of the medial collateral ligament with polypropylene mesh or a polyester suture in dogs.

The medial collateral ligament of one stifle in 20 adult dogs was excised and replaced with polypropylene mesh or a polyester suture. After 26 weeks, the fibrous tissue-prosthesis composites were evaluated clinically, morphologically, and biomechanically. Clinical lameness was not significantly different after 10 days. The polypropylene mesh reconstructions consistently had more fibrous tissue and greater collagenous ingrowth than the polyester suture reconstructions. There were four complications related to fixation of the polypropylene mesh prosthesis and one to the polyester suture. The polypropylene mesh reconstructions had greater stability and were biomechanically more similar to the natural ligaments than the polyester suture reconstructions. Although the results with polypropylene mesh were favorable, more challenging biomechanical testing and alternative anchoring techniques are required before polypropylene mesh can be recommended as a collateral ligament replacement in dogs.

Animals↗

Comparative development of SIRC rabbit corneal cells grown on polycarbonate- and polyester-based filters.

Statens Seruminstitut Rabbit Cornea (SIRC) cells were grown on sterile polycarbonate- and polyester-based filter inserts to evaluate the feasibility of substituting the polyester-based filter inserts for use in a previously developed permeability model. The two filter types were compared for differences in cellular growth rate and morphological changes following days 3, 7 and 10 in culture. There were no significant differences in the number of cell layers formed on any day examined. The numbers of cell layers formed with the polycarbonate-based filter inserts were 1.75 +/- 0.09, 2.53 +/- 0.14 and 2.93 +/- 0.16, for days 3, 7 and 10, respectively. The numbers of cell layers formed with the polyester-based filter inserts were 1.79 +/- 0.07, 2.23 +/- 0.11 and 2.90 +/- 0.13, for days 3, 7 and 10, respectively. The SIRC cells had a similar comparative morphology on each of the above days. Active cell growth was seen on each day with signs of maturation evident by day 7 in culture. The polyester-based filter inserts can be substituted in the previously established permeability assay without alteration of morphology or rate of growth, thus allowing confirmation of cell confluency prior to use in the permeability assay. It will also allow for photographic documentation of cell injury prior to recovery studies, without necessitating the preparation of extra samples for fixation at the time of initial injury. Future studies will be required to determine if there will be any alteration in the rate of permeability with a previously tested standard, before adoption of the new filter.

Animals↗

[Application of polyester fiber heart patches to secondary intraorbital implantation of hydroxyapatite spheres].

OBJECTIVE: To observe the effect of intraorbital implantation of hydroxyapatite spheres wrapped with polyester fiber heart patches. METHOD: According to the rectus contraction points four rectus were found and the rectus valves were created in anophthalmos. Then the hydroxyapatite sphere wrapped by the polyester fiber heart patch was inserted in the orbit. RESULT: There were 13 cases in this group. Of them 11 patients showed very good operative results, Local poor healing of bulbar conjunctiva and fascia occurred in 2 patients. The wound in one patient healed very well after a simple repairing operation and in the other the wound healed spontaneously without any special treatments. CONCLUSION: The effect of secondary intraorbital implantation of hydroxyapatite spheres wrapped by polyester fiber heart patches is positive. The polyester fiber heart patch is safe, reliable, cheap, very convenient in use and easy to obtain. It is a better substitute for sclera which is used to wrap the HA sphere.

Adult↗

[Inflammatory process caused by intraperitoneal injection of polyester in the rat: chemotactic activity in lavage fluid from the cavity].

Minced polyester threads introduced into peritoneal cavity of guinea pigs or rats cause a granulomatous inflammation with evidence of macrophage stimulation. Chemotactic agents play an important role in the inflammatory reaction; they may be exogenous and/or endogenous. These are released locally by the cells involved in inflammation. In this paper the chemotactic effects of the peritoneal fluids from rats bearing the polyester inflammatory process, have been studied on PMN cells "in vitro". The peritoneal cavity fluids were obtained by washing the cavity of untreated rats or rats intraperitoneally injected with polyester, 1, 3, 7, 14 days after the intraperitoneal injection. The chemotactic response was assayed by employing modified chemotaxis Boyden chambers (Blind Well Neuro Probe) and polymorphonuclear leukocytes from normal or treated rats. Quantification of the migration was calculated by chemotactic index (A/B) (B = random migration, A = chemotaxis). The results demonstrated that the peritoneal fluids taken 3 and 7 days after the intraperitoneal polyester injection, elicit an evident chemotaxis response greater than that showed by peritoneal fluids from control rats. It is suggested that chemotactic factors can be produced and released by mononuclear cells involved in the inflammatory process.

Animals↗

A study of polybutilate lubricated polyester sutures.

In the 49 patients in whom polybutilate coated polyester sutures were used, no adverse side-effects, such as increased redness, tenderness, pain or edema of the wounds, were noted. Primary healing was achieved in each patient. There were no suture related complications encountered during the early or late follow-up examinations. Polybutilate coated polyester sutures were found to be easy to work with. They were strong, pliable and handled and tied with ease. They had no tendency to twist, tangle or adhere to gloves or instruments. Tissue passage through skin, fascia, arteries, veins and Dacron vascular grafts was better than it was with uncoated polyester sutures and as good as with Teflon coated sutures. No unusual drag, pull or catching of the sutures was encountered. Over-all, the polybutilate coated polyester suture is thought to be a safe, reliable and an easy to use material for a wide variety of surgical procedures for which a strong nonabsorbable suture is indicated.

Adolescent↗