Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Peracetic Acid”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

[Comparative study on HAV and Poliovirus 2 inactivation cinetics with peracetic acid].

Hepatitis A virus and Poliovirus 2 inactivation tests were carried out using three peracetic acid concentrations (160, 320 and 640 mg/l) at different pH condition and at +20 degrees C temperature. HAV HM-175 strain was grown in FRhK4 cells and titrated in PFU (plaque technique) and the Poliovirus 2 strain was grown in monkey kidney cells RC-37 and titred in TCID50. The viral titration reduction was determined in the space of an hour with the disinfectant contact at 10-15 minutes intervals. The results obtained with the hepatitis A virus have shown a good linear trend between viral titration and contact time at the highest concentrations without any particular pH influence. The complete viral activity absence was achieved after 30-60 minutes of contact at 640 mg/l concentration. As regards Poliovirus 2 a good linear trend was highlighted between titrations and times at all the concentrations in shorter times at pH acid. The complete viral activity absence was obtained with 640 mg/l concentration after 30 minutes at pH acid. The HAV seems to own a higher resistance than Poliovirus 2 and Poliovirus 1 too.

Disinfectants↗

Liquid chemical sterilization using peracetic acid. An alternative approach to endoscope processing.

Recurrent episodes of endoscope contamination with nontuberculous mycobacterium and Pseudomonas species, coupled with employee concerns about exposure to 2% glutaraldehyde and the requirement for rapid scope turnover time, led to the investigation of an alternative method for endoscope processing. A prospective evaluation of 220 bronchoscopy procedures was carried out. Endoscope culture surveillance was performed twice a month for a 12 month period on all endoscopes. In addition, the deliberate inoculation of bronchoscopes with Mycobacterium gordonae was carried out. No indications of cross contamination were noted among the 220 bronchoscopy procedures after processing the scopes by the studied liquid chemical sterilization system using peracetic acid. Ongoing patient surveillance did not reveal any indications of cross contamination for nearly 15,000 patients diagnostic or surgical endoscopic procedures using instruments processed by this liquid chemical sterilization system. Twice a month for 12 months, bronchoscopes, colonoscopes, and gastroscopes were cultured for bacterium, fungi, and acid fast bacilli and showed no growth. Deliberate inoculation of bronchoscopes with M. gordonae showed the scopes were rendered sterile. No unusual occurrences of occupational chemical exposure were found in 11 individuals working with this liquid chemical sterilization system. The peracetic acid based sterilization system studied proved to be an effective, safe, and economical alternative to the glutaraldehyde method.

Adolescent↗

Evaluation of peracetic acid permeation during flash sterilization through pharmaceutical plastic polymers used in cytotoxic reconstitution units.

Peracetic acid (PAA) permeation in flash sterilization was studied using three different plastic infusion bags made of polypropylene and polyethylene, filled with glucose 5% or NaCl 0.9%. The pH was measured and acetic acid (AA) and PAA concentrations were made by reverse phase high-performance liquid chromatography (RP-HPLC). PAA was derivatized by oxidation of methyl tolyl sulfide (MTS) into methyl tolyl sulfoxide (MTSO) detected by ultraviolet (UV) absorbance at 230 nm. The technique has a sensitivity of 0.3 microg x L(-1) and was highly specific. Results showed that pH measurements remain constant and demonstrated the absence of PAA permeation, which was confirmed by the absence of AA permeation regardless of the brand tested, with both unwrapped and overwrapped infusion bags, when flash sterilization is applied. These results allow flash sterilization to be performed with unwrapped infusion bags without any risk of drug degradation by PAA. This makes compounding safer and easier, which improves productivity.

Antineoplastic Agents↗

[Efficient killing of anthrax spores using aqueous and alcoholic peracetic acid solutions].

We analysed the sporicidal effect of different concentrations of aqueous and alcoholic peracetic acid (PAA) solutions on anthrax spores in suspension and germ carrier tests. In activation of anthrax spores in suspension assays was achieved in less than 2 min using 1% PAA solution and in less than 3 min using 0.5% PAA solution, respectively. In contrast, in germ carrier as says, a test under practical conditions, spores on 38% of the germ carriers survived treatment with 1% PAA solution for 15 min. The use of PAA in 80% ethyl alcohol outclassed the sporicidal effect of aqueous PAA solutions in both suspension and germ carrier assays. Anthrax spores on 14% of germ carriers tested survived 30 min of treatment with a 1% aqueous PAA solution. In contrast anthrax spores were reliably inactivated under the same test procedure using a 1% alcoholic PAA solution for 30 min. The proven enhancement of the sporicidal effect of alcoholic PAA solutions should be kept in mind when using disinfectants in practice. In further surveys we will optimise the test conditions.

Bacillus anthracis↗

Peracetic acid (PAA) disinfection of primary, secondary and tertiary treated municipal wastewaters.

The efficiency of peracetic acid (PAA) disinfection against enteric bacteria and viruses in municipal wastewaters was studied in pilot-scale. Disinfection pilot-plant was fed with the primary or secondary effluent of Kuopio municipal wastewater treatment plant or tertiary effluent from the pilot-scale dissolved air flotation (DAF) unit. Disinfectant doses ranged from 2 to 7 mg/l PAA in the secondary and tertiary effluents, and from 5 to 15 mg/l PAA in the primary effluents. Disinfection contact times were 4-27 min. Disinfection of secondary and tertiary effluents with 2-7 mg/l PAA and 27 min contact time achieved around 3 log reductions of total coliforms (TC) and enterococci (EC). PAA disinfection also significantly improved the hygienic quality of the primary effluents: 10-15 mg/l PAA achieved 3-4 log reductions of TC and EC, 5 mg/l PAA resulting in below 2 log reductions. F-RNA coliphages were more resistant against the PAA disinfection and around 1 log reductions of these enteric viruses were typically achieved in the disinfection treatments of the primary, secondary and tertiary effluents. Most of the microbial reductions occurred during the first 4-18 min of contact time, depending on the PAA dose and microorganism. The PAA disinfection efficiency remained relatively constant in the secondary and tertiary effluents, despite of small changes of wastewater quality (COD, SS, turbidity, 253.7 nm transmittance) or temperature. The disinfection efficiency clearly decreased in the primary effluents with substantially higher microbial, organic matter and suspended solids concentrations. The results demonstrated that PAA could be a good alternative disinfection method for elimination of enteric microbes from different wastewaters.

Coliphages↗

A kinetic study of the effect of hydrogen peroxide and peracetic acid against Staphylococcus aureus and Pseudomonas aeruginosa using the bioscreen disinfection method.

Hydrogen peroxide and peracetic acid at pH 4 were examined against Staphylococcus aureus and Pseudomonas aeruginosa using the published 'Bioscreen' technique of biocide analysis. The data were examined using either classical Chick-Watson (CW) log-linear disinfection kinetics or the empirical, non-linear time Hom model. In some cases, modelling the data with the classical CW method gave good linear correlations, in others, however, deviations from this model were observed. In such cases the Hom model proved an adequate descriptor of the data. The Bioscreen technique therefore gives data which can be analysed using the normal mechanistic and empirical models currently available.

Disinfection↗

Effect of peracetic acid and aldehyde disinfectants on biofilm.

The effects of two aldehyde (Cidex, Endosporine) and four peracetic acid (PAA) (Nu Cidex, Anioxyde 1000, Hydraseptic, Peralkan) disinfectants on an Escherichia coli biofilm model were studied. The biofilm was prepared in glass tubes, and evaluated indirectly using a colourimetric method. The ability of the disinfectants to fix or remove the biofilm from tubes was determined by their detergent activity (DA). The two aldehyde derivatives and two of the PAA (Nu Cidex, Anioxyde 1000) agents fixed the biofilm. However, the effects of Hydraseptic and Peralkan were equivalent to the control (sterile water). Regardless of their disinfectant activity, PAA agents display different DAs that could be used to select the weakest biofilm-fixing agents. Users should be concerned about the efficiency of the cleaning stage of medical devices, and when choosing a PAA product, non-fixing ability should be considered in addition to antimicrobial activity.

Biofilms↗

Direct determination of peracetic acid, hydrogen peroxide, and acetic acid in disinfectant solutions by far-ultraviolet absorption spectroscopy.

In this paper we propose a rapid and highly selective far-ultraviolet (FUV) spectroscopic method for the simultaneous determination of peracetic acid (PAA), hydrogen peroxide, and acetic acid (AA). For this purpose we developed a novel FUV spectrometer that enables us to measure the spectra down to 180 nm. Direct determination of PAA, H(2)O(2), and AA, the three main species in disinfectant solutions, was carried out by using their absorption bands in the 180-220-nm region. The proposed method does not require any reagents or catalysts, a calibration standard, and a complicated procedure for the analysis. The only preparation procedure requested is a dilution of H(2)O(2) with pure water to a concentration range lower than 0.2 wt % in the sample solutions. Usually, the required concentration range can be obtained by the 10 times volume dilution of the actual disinfectant solutions. As the measured sample does not leave any impurity for the disinfection, it can be reused completely by using a circulation system. The detection limit for PAA of the new FUV spectrometer was evaluated to be 0.002 wt %, and the dynamic ranges of the measured concentrations were from 0 to 0.05 wt %, from 0 to 0.2 wt %, and from 0 to 0.2 wt % for PAA, H(2)O(2), and AA, respectively. The response time for the simultaneous determination of the three species is 30 s, and the analysis is applicable even to the flowing samples. This method may become a novel approach for the continuous monitoring of PAA in disinfectant solutions on the process of sterilization.

Acetic Acid↗

Ligand and pH influence on manganese-mediated peracetic acid epoxidation of terminal olefins.

[reaction: see text] Nineteen Mn(II) complexes were screened for the catalytic epoxidation of terminal olefins using peracetic acid. Few of these complexes are efficient catalysts at pH < 2, but many are effective at 1 mol % catalyst loading at pH 4. With 0.1 mol % loading, four complexes epoxidize 1-octene in approximately 80% yield in 5 min. The relative reactivity of the catalysts toward different olefins was probed using a multicomponent intermolecular competition reaction.

Alkenes↗

[Sporocidic activity of sodium hypochlorite and peracetic acid alone or combined against free or fixed spores or on biofilm].

In order to assess the sporocidal activity of chlorine and peracetic acid (PAA), alone and in combination, against a spored biofilm, the biofilms of two species (Bacillus subtilis ATCC 6633 and Bacillus megaterium ATCC 8245) were formed on inert support (tygon). A sporulation kinetic of these bacteria in biofilm was established. Sporocidal properties of chlorine and PAA were compared against free spores, spores fixed by drying and spores in biofilm. The combination of these two products was also tested. Minimal sporocidal concentrations (MSC) of the two products towards free spores were determined (contact time 5 mn). The efficacy of these MSC were evaluated in terms of contact time on adhered spores and on spores in biofilm. Chlorine and PAA exhibited an excellent sporocidal activity. The combination of PAA and chlorine, tested by checkerboard micromethod, was found to be synergistic in case of free or adhered spores. The spored biofilm showed a high resistance. The combination of these two products revealed then only an additive effect.

Bacillus megaterium↗

Evaluation of copper sulphate, formalin and peracetic acid in footbaths for the treatment of digital dermatitis in cattle.

The efficacy of three non-antibiotic products (copper sulphate, formalin and peracetic acid) was compared with the efficacy of erythromycin, when the four substances were applied in footbaths for the treatment of cows with digital dermatitis. The cows were divided into four groups on the basis of their current housing and randomly allocated to one of the four treatments. Cattle allocated to the non-antibiotic treatments were footbathed daily for seven days, but the cattle treated with erythromycin were footbathed for two days only. Complete records were obtained for 252 lesions from 169 cows. There were significant reductions in the lesion scores of all four groups, but there was no significant effect of treatment and no significant interaction between treatment and time.

Animals↗

Comparative evaluation of the sporicidal activity of new low-temperature sterilization technologies: ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid.

OBJECTIVE: This study was undertaken to evaluate the efficacy of 4 new low-temperature sterilization technologies: ethylene oxide with hydrochlorofluorocarbons, a liquid peracetic acid immersion system (Steris System 1 Processor), and 2 plasma sterilization processes that use vaporized hydrogen peroxide (Sterrad 100 and the Sterrad 100S). The Sterrad 100S system potentially improves sterilizer efficacy by using 2 cycles of a diffusion stage and a plasma stage per sterilization cycle. METHODS: Flat stainless steel carriers were inoculated with approximately 10(6) Bacillus stearothermophilus spores. These carriers were aseptically placed in the middle of 40 cm long stainless steel lumens (hollow tubes). Two types of lumen were used:(1) a lumen test unit with a removable 5 cm center piece (1.2 cm diameter) of stainless steel sealed to the narrower steel tubing by hard rubber septums and (2) a straight lumen. Three different diameters of the lumen test unit (1, 2, and 3 mm) and a single diameter of the straight lumen (3 mm) were studied. At least 40 replicates were performed for each type of lumen and sterilization method. After inoculation, the test unit was evaluated in 1 of the low-temperature sterilization technologies. After sterilization, the carriers were cultured in trypticase soy broth for 14 days at 55 degrees C and assessed for growth of B stearothermophilus spores. RESULTS: Our results demonstrated that ethylene oxide with hydrochlorofluorocarbons, the Sterrad 100s, and the Sterrad 100S half cycle were highly effective in killing approximately 10(6) B stearothermophilus spores present in the center of narrow-lumen stainless steel tubes. As the lumen diameter decreased with the lumen test unit, the Sterrad 100 demonstrated reduced ability to kill B stearothermophilus spores present on the carrier. At the smallest diameter tested (1 mm), the Sterrad 100 system failed 74% of the time. The Steris System 1 was not effective in completely eliminating the 10(6) inoculum under test conditions. CONCLUSION: The Sterrad 100S was significantly superior to the Sterrad 100 system and equivalent to ethylene oxide with hydrochlorofluorocarbons. Introduction of this new Sterrad 100S system should improve the margin of safety and reduce processing costs by its use of a shorter cycle time. The Steris System 1 is limited by diffusion of the chemical sterilant into the interior of the lumen test unit.

Disinfectants↗

A steady state kinetic analysis of the reaction of chloroperoxidase with peracetic acid, chloride, and 2-chlorodimedone.

The chloroperoxidase-peracetic acid-chloride-2-chlorodimedone system is used as a model for the investigation of enzymatic halogenation reactions. Systematic variation of the concentrations of the three substrates under steady state conditions yields sets of kinetic parameters containing both kinetic and mechanistic information. Three distinct enzyme species are involved in the halogenation cycle: native enzyme, compound I, and a short-lived halogenating intermediate. Analysis of the kinetic data is complicated by the fact that chloride serves as a substrate in the second step and as an inhibitor of the first step of the overall halogenation reaction. The inhibitor binding site on the native enzyme must be protonated prior to the binding of chloride. Chloride appears to be a competitive inhibitor for both compound I formation and cyanide binding to chloroperoxidase. Only the latter reaction can be studied directly in stopped-flow experiments since compound I disappears rapidly by reacting with chloride present in solution. Rate constants are calculated for the individual steps of the reaction at four different pH values. The rate constant for compound I formation is independent of pH, but the actual rate is reduced at lower pH values due to pH dependence of the chloride inhibition. The rate constant for the oxidation of chloride by compound I decreases with increasing pH. The rate of the halogenation step appears to be independent of pH.

Acetates↗

Sufficient penetration of peracetic acid into drilled human femoral heads.

Chemical sterilisation methods for musculoskeletal transplants have the problem of penetration into all tissue strata. The present study examined if a peracetic acid/ethanol solution penetrated to a sufficient extent into specifically prepared femoral heads. To this effect, 10 femoral heads have been provided with drillings (diameter 2 mm, depth 10 mm) at a distance of 15 mm (series B) and placed in a diffusion chamber with sterilisation solution. From an additional central drilling at the femoral neck junction, the sample drawing was made after 30 min each over a period of 4 h for the iodometric determination of peracetic acid (PAA) concentration. Ten femoral heads, which did contain only the central drilling, served as controls (series A). In 9 of the examined femoral heads of series A the defined minimum concentration of PAA of 0.2% (inactivation of bacteria, spores, fungi) has been clearly exceeded over the complete period of measurement. About 0.8% PAA (inactivation of viruses) was achieved within 4 h only with six femoral heads. Nine out of the 10 examined femoral heads in series B show a clearly improved penetration behaviour which was expressed in smaller standard deviations, a faster increase in concentration, as well as in higher starting and final concentrations (approx. 0.9%) of PAA. Previous drying in air leads to a faster penetration into the centre of the bone. Standardised drilling of de-cartilaged femoral heads creates favourable conditions for the penetration of the PAA sterilisation solution into the whole tissue and guarantees a sufficient inactivation of microorganisms.

Bone Transplantation↗

Genotoxicity of the disinfection by-products resulting from peracetic acid- or hypochlorite-disinfected sewage wastewater.

Wastewater disinfection is routinely carried out to prevent the spread of human pathogens present in wastewater effluents. To this aim, chemical and physical treatments are applied to the effluents before their emission in water bodies. In this study, the influence of two widely used disinfectants, peracetic acid (PAA) and sodium hypochlorite (NaClO), on the formation of mutagenic by-products was investigated. Wastewater samples were collected before and after disinfection, in winter and in summer, at a pilot plant installed in a municipal wastewater-treatment plant. Samples were adsorbed using silica C18 cartridges and the concentrates were tested for mutagenicity in the Salmonella typhimurium reversion test with strains TA98 and TA100. Non-concentrated water samples were tested with two plant genotoxicity assays (the Allium cepa root anaphase aberration test and the Tradescantia/micronucleus test). Mutagenicity assays in bacteria and in Tradescantia showed borderline mutagenicity in some of the wastewater samples, independent of the disinfection procedure applied. Negative results were obtained in the A. cepa anaphase aberration test. These results indicate that, in the conditions applied, wastewater disinfection with PAA and NaClO does not lead to the formation of significant amounts of genotoxic by-products.

Disinfectants↗

Ruthenium-catalyzed oxidation of alkanes with tert-butyl hydroperoxide and peracetic acid

The ruthenium-catalyzed oxidation of alkanes with tert-butyl hydroperoxide and peracetic acid gives the corresponding ketones and alcohols highly efficiently at room temperature. The former catalytic system, RuCl(2)(PPh(3))(3)-t-BuOOH, is preferable to the oxidation of alkylated arenes to give aryl ketones. The latter system, Ru/C-CH(3)CO(3)H, is suitable especially for the synthesis of ketones and alcohols from alkanes. The ruthenium-catalyzed oxidation of cyclohexane with CH(3)CO(3)H in trifluoroacetic acid/CH(2)Cl(2) at room temperature gave cyclohexyl trifluoroacetate and cyclohexanone with 90% conversion and 90% selectivity (85:15). The mechanistic study indicates that these catalytic oxidations of hydrocarbons involve oxo-ruthenium species as key intermediates.

Journal Article↗