[Carbomonoxyhemoglobin and methemoglobin in patients with and without a smoking history during ambulatory anesthesia. Consequences for the use of pulse oximetry].

Carboxyhemoglobin (COHb) and methemoglobin (MetHb) in venous blood were determined by oximetry in 1000 non-hospitalised preoperative patients. 370 of them were smokers (S), 630 non-smokers (NS). In addition, in five S we compared the oxygen saturation measured by pulse oximetry (SaO2, p) with that measured by in vitro oximetry (SaO2) and that calculated with reference to COHb (SaO2,korr). MetHb (0.66 +/- 0.21%, mean +/- standard deviation) was found to be of no relevance. COHb in S (5.12 +/- 2.25%, maximum 12.4%) was significantly higher than in NS (1.82 +/- 0.3%, range 0.9%-4.0%) and is therefore of importance in S for the oxygen transport and for the interpretation of SaO2, p, which overestimated SaO2 at a COHb level of 4.4 +/- 0.7% by 4.5 +/- 0.9%. The difference between SaO2, korr (calculated according to Forstner) differed from SaO2 by 0.66 +/- 0.5% only. We conclude that there is an indication for in vitro oximetry in non hospitalised smokers or cases of unknown smoking history. If oximetry is not available, both a reduction of O2-binding hemoglobin and an overestimation of SaO2 by pulse oximetry in an order of ten per cent should be taken into account. To compensate for dyshemoglobin fractions, pulse oximetry using more than two wavelengths is desirable.

Ambulatory Care↗

Accuracy of pulse oximetry in hypothermic neonates and infants undergoing cardiac surgery.

OBJECTIVES: To assess the accuracy of pulse oximetry under hypothermic conditions in neonates and infants undergoing cardiac surgery, and to assess the effect of probe site as well as probe site skin temperature on the reliability of pulse oximetry. DESIGN: Prospective Study. SETTING: Cardiac operating room and intensive care unit of children's hospital. PATIENTS: Twenty-five infants <3 months of age undergoing cardiac surgery with cardiopulmonary bypass. INTERVENTIONS: Pulse oximeter readings (Sp O2) from probes placed on the hand and foot were recorded at various skin temperatures and compared with hemoximeter oxygen saturations (Sa O2) obtained on simultaneously drawn arterial blood samples. Core temperature, arterial pressure and vasodilator use were recorded simultaneously. MEASUREMENTS AND MAIN RESULTS: Pulse oximetry bias (Sp O2 - Sa O2) increased to an unacceptable range (>+3% or <-3%) in 45.5% of the readings at foot probe site temperatures of <27 degrees. Pulse oximetry bias was within an acceptable range in 94.7% of the readings at temperatures >29 degrees. There was no significant difference between oximeter readings obtained from two probe sites (hand and foot). Administration of phenoxybenzamine improved the accuracy of pulse oximetry in ten infants at skin temperature of <27 degrees. CONCLUSIONS: Pulse oximetry readings in small infants are likely to be unreliable at skin temperatures of <27 degrees, irrespective of probe site. Intravenous phenoxybenzamine appeared to improve the accuracy of pulse oximetry at low temperatures.

Age Factors↗

Does implementing pulse oximetry in a critical care unit result in substantial arterial blood gas savings?

OBJECTIVES: To examine the impact of pulse oximetry on the use of arterial blood gas and other laboratory determinations and to examine predictors of the use of arterial blood gas measurements. DESIGN: Before (preoximetry)/after (postoximetry) study. SETTING: Thirty-bed multidisciplinary critical care unit. PATIENTS: Consecutive admissions of 300 patients (150 before and 150 after oximetry). MEASUREMENTS: For each patient examined, the number of arterial blood gas determinations, serum electrolyte levels, complete blood chemistries, arterial lactate levels, and creatinine samples were recorded for the initial 9 days of the stay in the critical care unit. These data were stratified by nursing shift (day vs night) and by the source of the admission (medical vs surgical). Other information collected included demographic variables, the severity of illness, the length of stay in the critical care unit, and various ventilatory parameters. RESULTS: Introducing pulse oximetry was associated with a marginal (10.3 percent; p < 0.025) reduction in the use of arterial blood gas determinations. This decrease was accounted for by changes occurring on the night shift and in the surgical patient. These findings were also observed for serum electrolyte determinations. No significant differences in the use of arterial blood gas measurements were found for medical patients. No significant differences were found in the use of arterial lactate levels, complete blood chemistries, or creatinine determinations. Significant predictors of arterial blood gas determinations included the number of days intubated, the number of ventilator orders, the number of days on an inspired oxygen content (FIO2) greater than 50 percent, and the acute physiology and chronic health evaluation II (APACHE II) score. CONCLUSIONS: The implementation of pulse oximetry in this manner gives an idea how effective the technology will be in reducing the use of arterial blood gas determinations without guidelines for the use of pulse oximetry. As only a marginal decrease was observed in the total population of medical and surgical patients, and only on the night shift, formal and standardized guidelines for the most efficient use of pulse oximetry should be considered. If these were considered, pulse oximetry may indeed make a significant contribution to improving the efficiency of care services.

Blood Chemical Analysis↗

An educational project to improve knowledge related to pulse oximetry.

BACKGROUND: Pulse oximetry is a frequently used, noninvasive monitoring tool for assessing arterial blood oxygenation. Physicians, registered nurses, and respiratory therapists are responsible for the accurate interpretation of pulse oximetry data as part of the evaluation and management of acutely and critically ill patients. OBJECTIVES: (1) To evaluate the extent of current knowledge about pulse oximetry and (2) to increase clinicians' knowledge of research-based practices related to the appropriate use of pulse oximetry and interpretation of its results. METHODS: A test/survey of 17 true-false questions based on the research-based practice protocol of the American Association of Critical-Care Nurses was developed to evaluate current knowledge of pulse oximetry. A convenience sample of medical, nursing, and respiratory therapy staff was invited to complete the test/survey before and several months after an educational program to improve staff members' knowledge of pulse oximetry. The program included educational forums, policy changes, competency checklists, and verification of inclusion of research-based principles in orientation programs. RESULTS: A total of 442 staff members completed the test/survey given before the educational program: 331 nurses, 82 physicians, and 29 respiratory therapists. The overall mean percentage of correct answers was 66%. Differences between disciplines were significant: respiratory therapists scored slightly higher (76%) than did nurses (64%) and physicians (66%) (P = .01). The scores on the test/survey given after the educational program increased significantly, from 66% to 82% (P < .01). CONCLUSIONS: This educational project improved staff members' knowledge of pulse oximetry monitoring.

Clinical Competence↗

A model for technology assessment applied to pulse oximetry. The Technology Assessment Task Force of the Society of Critical Care Medicine.

OBJECTIVES: To test a model for the assessment of critical care technology. To develop practice guidelines for the use of pulse oximetry. DATA SOURCES: A computer-assisted search of the English language literature and interviews with recognized experts in the field of pulse oximetry. STUDY SELECTION: Those studies that addressed one or more of the seven questions contained in our technology assessment template were analyzed. Study design was not a factor in article selection. However, the lack of well-designed clinical outcome studies was an important factor in determining the method of practice policy development we utilized. DATA EXTRACTION: A focus person summarized the data from the selected studies that related to each of the seven assessment questions. The preliminary data summary developed by the focus person was further analyzed and refined by the task force and then sent to 16 expert reviewers for comment. These expert comments were considered by the task force, and this final consensus report was developed. DATA SYNTHESIS: Pulse oximetry combines the principles of spectrophotometry and plethysmography to noninvasively measure oxygen saturation with a high degree of accuracy over the range of 80% to 100% saturation, assuming the device is being used according to the manufacturer's instructions and without any adverse operating conditions. The appropriate clinical uses of pulse oximetry fall into one of two broad categories: as a warning system based on continuous real-time measurement of arterial desaturation, or as an end-point for titration of therapeutic interventions. There are no published studies that allow for definitive, outcome-based conclusions concerning either the clinical impact or cost-benefit ratio of pulse oximetry. CONCLUSIONS: The model developed for technology assessment proved to be appropriate for assessing pulse oximetry. The available data have allowed us to develop an evidence-based practice policy for the use of pulse oximetry in critical care. Critical care clinicians, researchers, and industry have a shared responsibility to provide valid outcome and efficacy studies of new technologies.

Centers for Medicare and Medicaid Services, U.S.↗

Pulse oximetry is a poor predictor of hypoxemia in stable children with sickle cell disease.

OBJECTIVE: To evaluate the accuracy of the pulse oximeter to detect hypoxemia in patients with sickle cell disease in an ambulatory care setting. STUDY DESIGN: Simultaneous measurements of PaO(2), arterial oxygen saturation by co-oximetry (criterion standard), and pulse oximetry were performed in 21 children with sickle cell disease during 22 outpatient visits. The bias and precision of the pulse oximeter compared with measured arterial oxygen saturation by co-oximetry were determined. The sensitivity, specificity, and positive and negative predictive values of the pulse oximeter to detect hypoxemia (PaO(2) <70 mm Hg) were also calculated. RESULTS: The mean difference between pulse oximetry and measured oxygen saturation (bias) was 5.0% and the SD (precision) was 5.3. Twenty-one patients had a PaO(2) greater than 70 mm Hg; 7 of these (33%) were predicted to be hypoxic by pulse oximetry with values less than 93%, for a specificity to detect normoxia of 67%. CONCLUSION: Making treatment decisions based on pulse oximetry data alone in patients with sickle cell disease who are not acutely ill may be inappropriate.

Adolescent↗

The pulse in reflectance pulse oximetry: modeling and experimental studies.

OBJECTIVE: Reflectance pulse oximetry permits the use of alternative monitoring sites such as the face or torso, and is the approach commonly employed in fetal pulse oximetry systems. The purpose of this study is to investigate the impact of assumptions about the nature of arterial pulsatility on the calibration of such systems. METHODS: Monte Carlo simulations of reflectance pulse oximetry were run on a six-layer tissue model, varying depth and magnitude of the arterial pulse. SpO2 readings on and off the femoral artery obtained during desaturation studies in newborn piglets were compared to predictions. Results. Monte Carlo simulation results clarified the difference between deep and shallow pulsatility found with photon diffusion models, agreeing with earlier in vivo observations. Significant overestimation of SpO2 <75% and slight underestimation >75% is expected if a sensor is placed on a highly pulsatile site. The on- and off-artery SpO2 readings recorded during desaturation in the newborn piglet follow the model predictions. CONCLUSIONS: The sensitivity of reflectance pulse oximetry calibration to the depth and magnitude of arterial pulsatility reinforces the observation that monitoring site selection is of importance in optimizing reflectance pulse oximetry performance, particularly fetal pulse oximetry. Sites with palpable pulsatility should be avoided.

Animals↗

Continuous monitoring of fetal oxygen saturation by pulse oximetry.

OBJECTIVE: To compare spectrophotometric saturation values of fetal blood sampling to the saturation readings by pulse oximetry. METHODS: During a clinical trial, fetal oxygen saturation was monitored during labor by a fetal oxisensor and a fetal pulse oximeter. Fifty-one fetal scalp blood samples were assessed because of abnormal fetal heart rate (FHR) patterns. The pulse oximeter displayed only signal quality readings. The investigator had to perform adjustments if signal quality fell below 50%. After delivery, the saturation at the moment of fetal blood analysis could be read from a printout and compared to the saturation values of scalp blood sampling. RESULTS: The share of usable signal time was 51% overall, but only 40% in the 20-minute period during fetal blood sampling. Comparison with the reference method resulted in a median deviation of 6% (tenth percentile -10%; 90th percentile 18%) for pulse oximetry. The correlation coefficient between saturation values by pulse oximetry and fetal scalp blood sampling was 0.67. The correlation coefficient with the partial pressure of oxygen and oxygen saturation by pulse oximetry was 0.61, whereas it was 0.88 between partial pressure and saturation from the spectrophotometric analysis of the scalp sample. CONCLUSIONS: Fetal pulse oximetry corresponds satisfactorily to results from fetal blood analysis. Low invasiveness and continuous monitoring are the advantages of this method. At present, the available sensor generates only a limited amount of signal time. However, in combination with FHR monitoring, pulse oximetry promises greatly improved detection of fetal hypoxia.

Female↗

The sensitivity of room-air pulse oximetry in the detection of hypercapnia.

OBJECTIVE: To estimate the sensitivity of room-air pulse oximetry in the detection of moderate hypercapnia. METHODS: In this retrospective case-control study, charts were reviewed from patients with and without moderate hypercapnia (Pa co 2 >50 mm Hg), as determined by analysis of arterial blood gas samples obtained in the ED. Test characteristics (sensitivity, specificity, and likelihood ratios [LR) for room-air pulse oximetry < or = 96% to detect hypercapnia were calculated, as were confidence intervals. RESULTS: A total of 349 charts were eligible for abstraction-92 cases and 257 controls. A room-air pulse oximetry reading < or = 96% detected 88 of 92 cases of hypercapnia. Test characteristics were as follows (with 95% confidence interval): sensitivity, 0.96 (0.89-0.99); specificity, 0.39 (0.33-0.45), LR of a room-air pulse oximetry value >96%, 0.1 (0.04-0.3); and LR of a room-air pulse oximetry value < or = 96%, 1.6 (1.4-1.7). CONCLUSION: Room-air pulse oximetry detects moderate hypercapnia with high sensitivity.

Adult↗

The effect of pulse oximetry on emergency medical technician decision making.

OBJECTIVE: Relatively little is known about the use of pulse oximetry in the prehospital setting. The purpose of this study was to determine how emergency medical technicians (EMTs) use pulse oximetry information to influence their decisions regarding the involvement of advanced life support (ALS) personnel in a two-tiered emergency medical services (EMS) system. METHODS: EMTs were trained and authorized to use pulse oximetry in predefined clinical situations. The EMTs completed a questionnaire describing the influence of the oximetry information on their decision making regarding the involvement of ALS units. RESULTS: The EMTs reported an influence on their decisions whether to involve ALS care in 35 (12%) of 302 cases. The addition of the pulse oximetry information caused the EMTs to request ALS dispatch in 11 cases, to cancel a previously dispatched ALS response in eight cases, and not to request an ALS response from the scene when they otherwise would have requested it in 16 cases. CONCLUSION: Prehospital pulse oximetry has a measurable influence on EMT decisions concerning ALS involvement in a two-tiered EMS system. It improves system efficiency by helping to match patients to an appropriate level of care.

Advanced Cardiac Life Support↗

Evaluation of pulse oximetry in anemia from hemoglobin-H disease.

A patient with hemoglobin-H (Hb-H) disease developed an acute hemolytic crisis after treatment with trimethoprim and sulfamethoxazole. Despite her poor clinical condition and profound anemia (Hb, 2.7 g/dL), pulse oximetry continued to demonstrate a high O2 saturation percentage. Manipulation of Beer's law shows that anemia theoretically should not affect pulse oximetry values. The literature describes the effects of dyshemoglobinopathies such as carboxyhemoglobinemia and methemoglobinemia on O2 saturation percentage measured by pulse oximetry, but the effect of genetic hemoglobinopathies on pulse oximetry values is largely unreported. Because most hemoglobinopathies do not significantly change the protein-heme electronic interaction, the values of O2 saturation percentage determined through pulse oximetry should remain clinically valid. Hb-H is an exception to this generalization; as in patients with carboxyhemoglobinemia, pulse oximetry measurements showing high O2 saturation percentage do not correspond to high levels of oxygen available for delivery to tissues.

Adult↗

Pulse oximetry is accurate in acute anemia from hemorrhage.

HYPOTHESIS: Pulse oximetry is an accurate, noninvasive assay of oxygen saturation percentage (SaO2) in acutely severe anemia (less than 5 g/dL). DESIGN: A paired comparison of SaO2 by pulse oximetry (SpO2) and arterial blood gas analysis (SaO2) in patients with either acute gastrointestinal bleeding or blunt trauma with hematocrit of less than 20%. SETTING: An academic emergency department in a tertiary referral hospital with a Level I trauma center. PARTICIPANTS: Seventeen nonhypoxic patients were identified with initial hematocrit of less than 20% over a 9-month period. MEASUREMENTS AND MAIN RESULTS: Determination of SaO2 by pulse oximetry and arterial blood analysis was not statistically significantly different (P < .05) over a range of hemoglobin levels from 2.3 to 8.7 g/dL. The observed mean difference between SpO2 and SaO2 was 0.53 +/- 0.23% (mean +/- SEM; n = 17). The 95% confidence interval associated with this difference score ranged from 0.044 to 1.014. CONCLUSION: Despite reports that pulse oximetry is inaccurate below a hemoglobin concentration of 5 g/dL, our study suggested that this technology is accurate and reliable at 2.3 g/dL for nonhypoxic SaO2 values (SaO2 of more than 93%). The anemic endpoint where pulse oximetry either becomes inaccurate or simply fails to work has not been determined. Pulse oximetry overestimates SaO2 on average by 0.53% over a range of hemoglobin concentrations from 2.3 to 8.7 g/dL.

Acute Disease↗

Pulse oximetry during labour--does it give rise to hope? Value of saturation monitoring in comparison to fetal blood gas status.

OBJECTIVE: Purpose of this presentation is to show the diagnostic power of fetal pulse oximetry in comparison to the other blood gas parameters from fetal blood samplings (FBS). The distribution of saturation readings in acidotic fetuses and normally oxygenated fetuses should be established. STUDY DESIGN: A fetal pulse oximetry system (N400, FS14) was evaluated in a strictly observational study design based on blinded saturation display and on continuous data storing. The investigation was performed on 170 fetuses with non-reassuring fetal heart rate (FHR)-tracings. Since pulse oximetry readings were not available for decision finding, the clinical management was based on electronic fetal monitoring and fetal blood samplings. The oxygen saturation from FBS or umbilical cord blood was measured by blood gas analysers with an integrated hemoximeter (Bayer 865; ABL 625, Radiometer) and biosensors measuring lactate as metabolic component. Out of the 170 cases 17 cases were defined as group of acidemia (pH(umb.art.) < 7.16 + BD<-9.4). The distribution of saturation readings and the duration of desaturation periods (in minutes and percentage of total monitoring time SPO2 below 30%) were determined. ROC curve analysis from FBS preceding delivery compared the diagnostic power of other blood gas parameters with oxygen saturation. The Wilcoxon test for uneven pairs was used. RESULTS: The distribution of oxygen saturation in the normal group of fetuses differs significantly from the acidemic group. The correlation coefficient between both methods to determine oxygen saturation was r=0.66. A specific evaluation of the distribution of SPO2 shows an overestimation of pulse oximetry in the low range and an underestimation in the high range of saturation. ROC-curve analysis showed a good diagnostic power of lactate in comparison to the oxygen saturation measured by pulse oximetry or by hemoximetry. CONCLUSIONS: The advantage of continuous fetal pulse oximetry surveilling the fetus under suspicion of hypoxia appears limited by the poor diagnostic power of the respiratory parameter saturation itself and by the impairment of the precision of the technology.

Acidosis↗

The accuracy of pulse oximetry in the emergency department.

The objective of this retrospective study was to identify factors affecting the accuracy of pulse oximetry in the ED. Over a 3-year period, 664 consecutive emergency department (ED) patients had simultaneous arterial blood gas (ABG) and pulse oximeter readings taken. Pulse oximeter saturations (SpO2) were compared with ABG CO-oximeter saturations (SaO2) for accuracy. Multiple variables including age, sex, hemoglobin, bicarbonate, pH, and carboxyhemoglobin (COHb) were analyzed to see if they affected SpO2 accuracy. ROC curves were used to determine the best pulse oximeter threshold for detecting hypoxia. Using multivariate analysis, COHb was the only statistically significant factor affecting the accuracy of pulse oximetry. In patients with COHb <2%, SpO2 overestimated SaO2 by more than 4% in 8.4% of cases. In patients with COHb > or = 2%, SpO2 overestimated SaO2 by more than 4% in 35% of cases. The best pulse oximetry threshold for detecting hypoxia is 92%. At this threshold, if COHb is <2%, pulse oximetry has a sensitivity of 0.92 and specificity of 0.90. If COHb is > or =2%, sensitivity is 0.74 and specificity is 0.84. For patients likely to have a COHb < 2, pulse oximetry is an effective screening tool for detecting hypoxia. However, more caution must be exercised when using pulse oximetry in patients likely to have a COHb > or = 2%.

Blood Gas Analysis↗

Overnight home oximetry: can it identify patients with obstructive sleep apnea-hypopnea who have minimal daytime sleepiness?

BACKGROUND: Overnight home oximetry is being widely used as a case selection technique for patients with suspected obstructive sleep apnea-hypopnea (OSAH). In the absence of excessive daytime sleepiness (EDS), patients with snoring and/or witnessed apnea are considered to have low probability of OSAH. METHODS: Patients suspected to have OSAH, who denied EDS, and had a normal overnight home oximetry were studied by polysomnography for presence of significant OSAH (apnea/hypopnea index (AHI) > 15/h). RESULTS: Twelve (40%) of the 30 patients studied had significant OSAH. All had a 2% oxygen desaturation index of less than 10/h. The sensitivity of oximetry increased at lower desaturation indices butthis was associated with decreased specificity. Review of oximetry waveform pattern, by experienced physicians, did not improve the diagnostic accuracy. Combining oximetry with a clinical prediction rule would have reduced the need for polysomnography by 30%. CONCLUSION: Many patients, who present with snoring and/or witnessed apnea and are referred to a sleep disorder clinic for suspected OSAH, may have significant OSAH even if they deny EDS. Overnight home oximetry did not help discriminate between those patients with or without OSAH.

Adult↗

Accuracy of pulse oximetry during exercise stress testing.

Pulse oximetry is used extensively during exercise stress-testing in the clinical and sports medicine settings. There are few validation studies to assess the appropriateness of using pulse oximetry under conditions of potentially compromised peripheral blood flow. To study the accuracy of pulse oximetry during severe exercise stress, 10 athletes undertook 3 bouts of exhaustive exercise; once at an intensity requiring VO2max (max), once at 115% of VO2max (Smax), and once at Smax while FIO2 was increased to 0.30. The results indicate relatively large underestimations occur when pulse oximetry is used to estimate %SaO2 during exercise, when compared to the criterion samples of gas analysis in arterial blood. These differences were exacerbated as the exercise intensity increased from a mean(+/- SE) difference of 2.9 +/- 0.7 %SaO2 at max to 4.6 +/- 0.7 %SaO2 at Smax. Breathing a higher FIO2 reversed the hypoxemia that occurred during the normoxic exercise, however, pulse oximetry measurements failed to detect this alteration in %SaO2. Estimates of oxygen saturation during severe exercise using pulse oximetry should be viewed with caution, as potentially large errors may occur.

Adolescent↗

Screening for pulmonary arteriovenous malformations: contrast echocardiography versus pulse oximetry.

Pulmonary arteriovenous malformations (PAVM) cause right-to-left shunt and imply risk of paradoxical embolism and cerebral abscess. These complications can be prevented by appropriate treatment. Detection of PAVMs is therefore important, so simple and reliable screening methods are needed for this purpose. The aim of this investigation was to compare pulse oximetry and contrast echocardiography as screening tools for detection of pulmonary arteriovenous malformations. Eighty-five hereditary haemorrhagic telangiectasia (HHT) patients and first-degree relatives identified in a comprehensive study of HHT-families in the county of Funen, Denmark, were investigated. Standing and supine pulse oximetry in room air was performed in all subjects, and in subjects with symptoms and/or abnormal pulse oximetry in room air, supine pulse oximetry breathing 100% oxygen was also performed. Transthoracic echocardiography with intravenous injection of echo contrast was performed in all subjects. Outcome measures were oxygen saturation change >2% units on changing body position and echo contrast observed in the left-sided heart chambers. Positive contrast echocardiography indicating the presence of PAVM was found in 47 subjects, whereas pulse oximetry was abnormal in only 16. The results strongly suggest that contrast echocardiography is a more sensitive screening tool for PAVMs than pulse oximetry.

Adolescent↗

Fetal pulse oximetry.

Within the last ten years several groups adapted pulse oximetry to be used in the fetus. The obvious advantage of this technology is the fact that a biochemical parameter--the arterial oxygen saturation--can be measured continuously during delivery. Nevertheless, the continuous information about the fetal oxygenation during delivery has a couple of obstacles to surmount. It is well known that fetal reflectance pulse oximetry may be influenced by a number of artifacts. In addition, severe physiological considerations should remind us of the limited diagnostic value of saturation monitoring alone in order to predict fetal acidosis. Some recent articles deal with the predictive value of fetal pulse oximetry for fetal compromise. While it appears that the fetal wellbeing is more likely to be in accordance with a normal saturation measured by current pulse oximetry systems, the number of fetuses detected by pulse oximetry suffering from hypoxia seems to be low. Different authors describe a poor sensitivity to predict fetal compromise. One reason therefore may be the reduced precision of the oxysensor in the low saturation range. Therefore, we conclude that the current generation of fetal pulse oximetry sensors is not improving the quality of combined fetal monitoring of fetal heart rate and fetal scalp blood analysis.