Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Neuronavigation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Spatial congruence of neuronavigated transcranial magnetic stimulation and functional neuroimaging.

OBJECTIVES: Transcranial magnetic stimulation (TMS) is progressively gaining relevance as a tool in cognitive neuroscience and clinical research. However, most studies in this field do not consider individual anatomy. Neuronavigational devices allow to guide the coil to a specific cortical area, predetermined by functional magnetic resonance imaging (fMRI). Therefore, it is crucial to know whether the area of a certain function as identified by fMRI corresponds to the area where the TMS should be placed in order to influence this function. METHODS: We investigated the spatial relation between the cortical area activated by a motor task in fMRI and the area of magnetically evoked motor potentials (MEP) in 8 subjects, using a spacing of 5x5 mm. A neuronavigational system was adapted for coil positioning and for the registration of the stimulation coordinates. RESULTS: A spatial divergence of the centers of gravity from fMRI and MEP was found with a mean distance of about 10 mm, with the MEP centers being, by a mean derivation of 7.5 mm, consistently anterior to the center of fMRI activation. However, regarding MEP areas and fMRI activities, a large overlap was found for stimulation intensities of both 110 and 120% motor threshold. CONCLUSIONS: The combination of fMRI and neuronavigated TMS is useful for non-invasive investigation of individual cortical functions predetermined by fMRI. Whereas both are spatially by and large congruent, discrepencies in the exact spatial relation between MEP and fMRI areas should be considered and further studied.

Adult↗

Virtual placement of frontal ventricular catheters using frameless neuronavigation: an "unbloody training" for young neurosurgeons.

OBJECTIVE: To evaluate virtually the reliability of freehand puncture of the anterior horn of the lateral ventricle and to provide realistic, but unbloody training for young neurosurgeons. METHODS: Virtual placement of ventricular catheters was performed repeatedly by neurosurgical doctors and thereafter controlled by neuronavigation. With the help of a frameless stereotactic navigation device they virtually had to hit the anterior horn of the lateral ventricle on the MRI of 29 brains with normal ventricular sizes and 60 pathological ventricles, respectively. The catheter placement was simulated using the pointer of the navigation system (EasyGuide Neuro). The monitor screen was blinded, so that on-line control was impossible. Virtual elongation of the pointer tip was performed on the workstation and the position of the virtual catheter was evaluated on a printout. RESULTS: Virtual freehand catheter placement was performed 145 times into the MRIs of the normal brains. In 66 cases (45%) the site of the catheter tip was judged as accurate as shown by the navigation system. No difference concerning the number of correctly placed catheters was observed when comparing more and less experienced doctors. The results in the 60 pathological MRIs of patients differed with respect to the size of the ventricles: in narrow ventricles an accurate placement succeeded in 7 of 22 cases (32%), moderately enlarged ventricles were accurately hit in 15 out of 32 cases (46%) and wide ventricles in 5 of 6 attempts (83%), respectively. CONCLUSION: This setup is a simple, practicable tool for neurosurgical education. The virtual freehand placement of ventricular drains controlled by neuronavigation provides an unbloody training of a routine neurosurgical procedure in a realistic setting without the risk of injuring a patient. Neuronavigation systems can serve therefore as a link between learning from observation and handling the real situation.

Adolescent↗

Error analysis in cranial neuronavigation.

Neuronavigation systems are now an important component of many modern neurosurgical treatment strategies. Their support facilities intraoperative orientation and makes neurosurgical operations more precise and less traumatic. Computer-aided neurosurgery is definitively not a temporary fashionable phenomenon, the concept of neuronavigation is here to stay. This report summarizes a ten-years-long experience and presents an error analysis of 108 failures (12.4 %) in a total of 874 image-guided cranial neurosurgical procedures with an arm-linked (mechanical) system and two different infrared-light emitting (optical) systems. The application of neuronavigation incurs multiple reasons for pitfalls because of the complex man-machine interface. Principally, we have to differentiate two types of errors: "machine made errors" due to soft- or hardware failure and "man made errors" generally, due to inadequate handling of the navigation system. The error analysis demonstrated that the so-called human interface plays the main role causing a high error rate.

Bias↗

Frameless neuronavigation in modern neurosurgery.

A fundamental effort in neurosurgery is to reduce surgical trauma. Microneurosurgical technique combined with precise localization of lesions, can minimize the invasiveness of neurosurgical procedures. This report summarizes the utility of frameless neuronavigator systems and examines their value in reducing operative invasiveness. The basic principle of neuronavigation is the virtual linkage between digitized neuroradiological data and real anatomical structures, allowing an excellent three-dimensional orientation by real-time graphic-anatomic interaction. As frameless graphic interactive neuronavigation is developed further, these devices should become an important component of the modern microneurosurgical armamentarium and reduce surgical morbidity.

Humans↗

Endoscopic facial skeletal surgery using a neuronavigator.

In the reconstruction of asymmetrical deformities of the facial skeleton, both an endoscope and a neuronavigator have been used. The endoscope allows the surgeon a wide view of the object on a television monitor, reduces the scarring, minimizes the undermined field, and reduces the need to work blind. The neuronavigator is a frameless computed tomographic stereotactic device that has been mainly used in neurosurgery. The device is easy to use and can offer the surgeon three-dimensional coordinates of the status during the operation. We have used this new technique in three clinical cases, two involving augmentation of the zygomatic bone on one side and one involving reduction of the frontal bone on one side. The surgical techniques we used and the versatility of both the endoscope and the neuronavigator are discussed herein based on our own experience.

Adolescent↗

Open surgery assisted by the neuronavigator, a stereotactic, articulated, sensitive arm.

A new computed tomographic-stereotactic device that translates the operating point onto preoperative computed tomographic (CT) images, the Neuronavigator, has been developed. We have applied this system to various neurosurgical procedures to examine its usefulness. The system consists of a 6-joint sensing arm and a 16-bit personal computer. It projects the location of the arm tip onto a corresponding CT slice with a cursor that guides the surgeon toward the intracranial target during open surgery. The system also projects the location of the tip onto angiograms, and when used in conjunction with echography or a transcranial Doppler (TCD) flow meter, the surgeon's ability to navigate is enhanced. Sixty-eight patients underwent operation with the Neuronavigator. The navigation system worked as the core of a multimodal three-dimensional data base that proved to be useful during surgery. The maximum detection error was 2.5 mm, which was considered sufficient for open microsurgery. It also proved useful in designing the position of a craniotomy, in targeting deep-seated mass lesions, and in tracing the tumor edge, which had been identified on a CT scan. When the angiogram was combined with the navigator, it became easy to identify key vessels within a small operating field. The system was also combined with a TCD flow meter. This combination makes it possible to translate the measuring point of the TCD directly into CT coordinates, improving the precision of location of the TCD probe. The Neuronavigator combines various diagnostic images into one database and effectively guides the surgeon during surgery.

Adolescent↗

Integration of functional magnetic resonance imaging supported by magnetoencephalography in functional neuronavigation

OBJECTIVE: In this study, the intraoperative visualization of functional data provided by functional magnetic resonance imaging (fMRI) and magnetoencephalography (MEG) leading to functional neuronavigation is demonstrated in surgery around the motor strip. METHODS: In seven patients with lesions adjacent to the central region, fMRI was performed with a 1.5-Tesla magnetic resonance system, using axial echo-planar imaging with a motor and a sensory task. Somatosensory and motor evoked fields were recorded with a biomagnetometer. fMRI and MEG were matched to an anatomic three-dimensional magnetic resonance image set by a contour fit. Then this three-dimensional image data set was transferred to the navigation microscope and displayed in the eyepieces of the microscope during surgery. Additionally, intraoperative recording of somatosensory evoked potentials was performed for verification of the central sulcus. RESULTS: In all cases, the projection of fMRI and MEG data into the operating viewing field allowed easy identification of the central region, which was confirmed by phase reversal of somatosensory evoked potentials in each case. fMRI and MEG measurements yielded corresponding results in each patient. CONCLUSION: Functional neuronavigation with integration of fMRI and MEG allows the fast identification of eloquent brain areas. The widespread availability of fMRI will result in a broad availability of functional neuronavigation, which will, in turn, contribute to the successful surgery of lesions in eloquent brain areas with lower morbidity.

Journal Article↗

Multimodal cranial neuronavigation: direct integration of functional magnetic resonance imaging and positron emission tomography data: technical note.

OBJECTIVE: This is the first report of the direct integration of functional magnetic resonance imaging (fMRI) and positron emission tomography (PET) data into cranial neuronavigation. METHODS: In a patient with a left precentral oligodendroglioma (World Health Organization Grade III), the Zeiss MKM system (Carl Zeiss Co., Oberkochen, Germany) was used for navigation based on thin-slice, T1-weighted, contrast-enhanced magnetic resonance imaging (MRI) scans. fMRI and methionine PET data were integrated by landmark matching, with reference to skin fiducials. RESULTS: The inaccuracy of the image fusion between fMRI and T1-weighted MRI data was 1.7 mm, that between PET and T1-weighted MRI data was 4.3 mm, and that for the subsequent registration of the navigation was 1.2 mm. The correct fMRI localization of the precentral gyrus was intraoperatively verified by cortical somatosensory evoked potential (phase-reversal) monitoring. Although the tumor was not clearly defined in the MRI scans, [11C]methionine PET demonstrated a clear tumor border, enabling us to achieve gross total tumor removal without postoperative functional deficits. CONCLUSION: Functional neuronavigation permits observation and preservation of relevant brain areas. Other functional areas (such as short-term memory areas) that can be detected only by fMRI might also warrant future monitoring. The simultaneous integration of fMRI and PET data adds a new dimension to cranial neuronavigation, enabling the observation of tumors in relation to functional cortical areas (in our case, the motor strip).

Brain↗

Methodological and technical issues for integrating functional magnetic resonance imaging data in a neuronavigational system.

OBJECTIVE: The aim of this article was to analyze the technical and methodological issues resulting from the use of functional magnetic resonance image (fMRI) data in a frameless stereotactic device for brain tumor or pain surgery (chronic motor cortex stimulation). METHODS: A total of 32 candidates, 26 for brain tumor surgery and six chronic motor cortex stimulation, were studied by fMRI scanning (61 procedures) and intraoperative cortical brain mapping under general anesthesia. The fMRI data obtained were analyzed with the Statistical Parametric Mapping 99 software, with an initial analysis threshold corresponding to P < 0.001. Subsequently, the fMRI data were registered in a frameless stereotactic neuronavigational device and correlated to brain mapping. RESULTS: Correspondence between fMRI-activated areas and cortical mapping in primary motor areas was good in 28 patients (87%), although fMRI-activated areas were highly dependent on the choice of paradigms and analysis thresholds. Primary sensory- and secondary motor-activated areas were not correlated to cortical brain mapping. Functional mislocalization as a result of insufficient correction of the echo-planar distortion was identified in four patients (13%). Analysis thresholds (from P < 0.0001 to P < 10(-12)) more restrictive than the initial threshold (P < 0.001) had to be used in 25 of the 28 patients studied, so that fMRI motor data could be matched to cortical mapping spatial data. These analysis thresholds were not predictable preoperatively. Maximal tumor resection was accomplished in all patients with brain tumors. Chronic motor cortex electrode placement was successful in each patient (significant pain relief >50% on the visual analog pain scale). CONCLUSION: In brain tumor surgery, fMRI data are helpful in surgical planning and guiding intraoperative brain mapping. The registration of fMRI data in anatomic slices or in the frameless stereotactic neuronavigational device, however, remained a potential source of functional mislocalization. Electrode placement for chronic motor cortex stimulation is a good indication to use fMRI data registered in a neuronavigational system and could replace somatosensory evoked potentials in detection of the central sulcus.

Adolescent↗

Factors influencing the application accuracy of neuronavigation systems.

OBJECTIVE: The overall accuracy of neuronavigation systems may be influenced by (1) the technical accuracy, (2) the registration process, (3) voxel size and/or distortion of image data and (4) intraoperative events. The aim of this study was to test the influence of the registration and imaging modality on the accuracy. METHODS: A plexiglas phantom with 32 rods was taken for navigation targeting. Sixteen fiducials were attached to the surface of the phantom forming two different attachment patterns (clustered vs. diffusely scattered). This model was scanned by MRI and CT (1-mm slices). Registration was performed using different numbers and attachment patterns of the fiducials. Using CT or MRI, the localization error was measured in image space as the Euclidean distance between targets defined in image space and those detected in the physical space. Accuracy was measured with two commercial systems, the Zeiss MKM and the StealthStation. RESULTS: The mean localization error varied between 1.59 +/- 0.29 mm (MKM, 8 scattered fiducials, CT scanning) and 3.86 +/- 2.19 mm (MKM, 4 clustered fiducials, MRI). The worst localization error was 9.5 mm (MKM). In case of an optimal registration, the 95th percentile for the localization error was 2.2 (MKM) and 2.75 mm (StealthStation). The imaging modality has only minor influence on the localization error, with CT increasing accuracy minimally. Both the fiducial number and the attachment pattern critically influence the localization error: 8 fiducials and a generalized attachment pattern increase the accuracy significantly. No correlation between the calculated registration accuracy and the measured localization accuracy was found. CONCLUSION: The application accuracy of different neuronavigation systems critically depends on the registration. The calculated registration accuracy provided by the system does not correspond to the localization error found in reality. The accuracy of frameless neuronavigation systems is comparable to that of classical frame-based stereotactic devices.

Magnetic Resonance Imaging↗

Infrared-based neuronavigation and cortical motor stimulation in the management of central-region tumors.

An infrared-based neuronavigation device (Surgical Microscope Navigator) integrating a pointer system with microscope guidance, is presented. We report our experience with this system in 17 patients undergoing surgery for space-occupying lesions of the central region. Cortical motor stimulation was additionally used in selected cases. The system was helpful in all operations by guiding craniotomy, corticotomy, or extent of tissue resection. Gross total tumor removal was possible in all patients but 1. Technical problems occurred in 1 case. Postoperative neurological worsening was found in 3 patients; this was reversible within a few weeks in 2 of them. In 9 cases, neuronavigation (combined with cortical stimulation, if necessary) probably prevented permanent neurological injury by exactly localizing tumors in the central area. It is concluded that neuronavigation (combined with motor cortex stimulation) may decrease neurological injury or neurosurgical invasiveness in lesions of the central region.

Astrocytoma↗

[Quality securing procedures in neurosurgical operations. Experiences with intraoperative computed tomography and neuronavigation].

In the department of Neurosurgery of the Unfallkrankenhaus Berlin, experiences with neuronavigation and intraoperative computed tomography were acquired and reviewed on a descriptive basis. The main parameter for the evaluation was target point accuracy for the neuronavigation and image quality for the intraoperative ct. Additionally, both systems were evaluated about the requirement of time, staff and technical equipment. The analysis shows that both techniques are apted for quality control with the operation of intracranial lesions. Most problems with the handling of the new methods decreased with growing experience. On the technical aspect there are still problems with target accuracy for the neuronavigation and image quality for the ct-scans. However, solutions due to future technical improvement are perceived. The increase of time requirement is compensated with the rise of operation security. An even higher quality control is achieved with combination of both systems.

Brain↗

[Neuronavigation in third ventricle tumors].

The authors present the results of neuronavigation as a help to open neurosurgery for the tumors of the third ventricle. From January, 1995 to August, 1999, six image-guided surgical procedures were performed to remove third ventricle lesions : 4 colloïd cysts, 1 ependymoma, and 1 craniopharyngioma. The operative approach was transcortical in 5 cases, and transcallosal in 1 case. The use of neuronavigation allows a decrease of the surgical trauma during the surgical approach. The procedure secures the neurosurgeon in the choice and execution of his pathway to the target. It becomes however less accurate after opening the ventricle, because of the brainshift induced by the loss of cerebrospinal fluid becomes important. Nevertheless, neuronavigation is useful in the surgery of the third ventricle, especially if it is used with neuroendoscopy.

Adult↗

SonoWand, an ultrasound-based neuronavigation system.

OBJECTIVE: We have integrated a neuronavigation system into an ultrasound scanner and developed a single-rack system that enables the surgeon to perform frameless and armless stereotactic neuronavigation using intraoperative three-dimensional ultrasound data as well as preoperative magnetic resonance or computed tomographic images. The purpose of this article is to describe our two-rack prototype and present the results of our work on image quality enhancement. DESCRIPTION OF INSTRUMENTATION: The system consists of a high-end ultrasound scanner, a modest-cost computer, and an optical positioning/digitizer system. Special technical and clinical efforts have been made to achieve high image quality. A special interface between the ultrasound instrument and the navigation computer ensures rapid transfer of digital three-dimensional data with no loss of image quality. OPERATIVE TECHNIQUE: The positioning system tracks the position and orientation of the patient, the ultrasound probe, the pointer, and various surgical instruments. This makes it possible to update the three-dimensional map during surgery and navigate by ultrasound data in a similar manner as with magnetic resonance data. METHODS: The two-rack prototype has been used for clinical testing since November 1997 at the University Hospital in Trondheim. EXPERIENCE AND RESULTS: The image quality improvements have enabled us, in most cases, to extract information from ultrasound with clinical value similar to that of preoperative magnetic resonance imaging. The overall clinical accuracy of the ultrasound-based navigation system is expected to be comparable to or better than that of a magnetic resonance imaging-based system. CONCLUSION: The SonoWand system enables neuronavigation through direct use of intraoperative three-dimensional ultrasound. Further research will be necessary to explore the potential clinical value and the limitations of this technology.

Equipment Design↗

[Integrating functional magnetic resonance imaging in neuronavigation surgery of brain tumors involving motor cortex].

OBJECTIVE: To assess the value of integrating blood oxygen level dependent (BOLD) functional magnetic resonance imaging (fMRI) in neuronavigation surgery of brain tumors involving motor cortex. METHODS: A total of 58 patients with brain tumors in or directly adjacent to the motor cortex, with 18 lesions located in primary motor area, 18 lesions located in premotor area, 11 lesions located in primary motor sensory area, 9 lesions located in primary sensory area, and 2 lesions located in supplementary motor area respectively, were randomly divided into 2 groups: trial group including 30 cases undergoing BOLD navigation and control group with 28 cases undergoing routine navigation. A prospective random and matched controlled study was carried out to compare the clinical outcome between the two groups. For the patients in the trial group, the motor tasks consisted of simple flexion-extension finger movements and finger-to-thumb touching in a repeating, pre-planned sequence of either hand. A standard 1.5 T MR system had been utilized to localize the cortical motor hand area, using the BOLD contrast technique. The BOLD images were integrated with the routine navigational MR images (T1-weighted three-dimensional fast spoiled gradient recalled sequence), and then co-registered to the neuronavigation system. For the patients in the control group, the navigational MR imaging examinations were carried out only. RESULTS: The statistics analysis confirmed a good balance of main variations between the trial and control groups. The percentage of completely resection of tumors was 86.7% in trial group and 60.7% in control group (P < 0.05). The postoperative contralateral extremities muscle strength were 4.3 +/- 1.1 degree for trial group and 2.5 +/- 1.9 degree for the control group (P < 0.01). The motor functional deficit was observed in 23.3% of the cases of trial group and 71.4% of the cases in trial group (P < 0.05). The mean Karnofsky prognosis scale of the trial group was 88 +/- 27, significantly higher than that of the control group (65 +/- 32, P < 0.01). CONCLUSION: BOLD functional MR imaging is of great value in surgical planning and intraoperative functional brain mapping of motor cortex individually. To integrate BOLD data with the routine navigational MR images can supply more precise and real-time information about the relationship between lesions and neighboring cortical motor area. It should be used in neuronavigation surgery to increase the ratio of total resection of brain tumors and decrease the risk of postoperative hemiplegia.

Adolescent↗

Development and human factors analysis of neuronavigation vs. augmented reality.

This paper is focused on the human factors analysis comparing a standard neuronavigation system with an augmented reality system. We use a passive articulated arm (Microscribe, Immersion technology) to track a calibrated end-effector mounted video camera. In real time, we superimpose the live video view with the synchronized graphical view of CT-derived segmented object(s) of interest within a phantom skull. Using the same robotic arm, we have developed a neuronavigation system able to show the end-effector of the arm on orthogonal CT scans. Both the AR and the neuronavigation systems have been shown to be within 3mm of accuracy. A human factors study was conducted in which subjects were asked to draw craniotomies and answer questions to gage their understanding of the phantom objects. The human factors study included 21 subjects and indicated that the subjects performed faster, with more accuracy and less errors using the Augmented Reality interface.

Adult↗

[Usefulness of neuroendoscopy and a neuronavigator for removal of clival chordoma].

We report a case of large clival chordoma. The patient was a 56-year-old male who was admitted to our hospital with left eye ptosis and diplopia of 2 months duration. On admission, neurological examinations revealed oculomotor nerve palsy of the left eye. Skull radiographs with polytomographs demonstrated marked destruction of the clivus. A plain computed tomography (CT) scan revealed a large iso-attenuated mass in the clivus, extending anteriorly into the sphenoidal sinus, superiorly into the suprasellar cistern, bilaterally into the petrous apex, posteriorly into the prepontine cistern and caudally into the foramen magnum. An enhanced CT scan demonstrated a slightly enhanced tumor. A high-resolution bone-window CT scan revealed marked destruction of the clivus and bilateral petrous apex. Magnetic resonance imaging (MRI) scans disclosed a large enhanced mass extending superiorly into the suprasellar cistern, bilaterally into the petrous apex and inferiorly into the foramen magnum. The tumor extended so widely that we decided on a one-stage operation via a transsphenoidal sublabial transseptal approach and transoral transpalatal approach. At surgery, we employed a neuronavigator and Codman 4-mm rigid neuroendoscope with 0 degree, 30 degrees and 70 degrees angled lenses. The tumor was very soft and suckable, and could be easily removed by applying CUSA, a pituitary curette and suction. The neuronavigator was particularly useful because the surgeon had a real-time two-dimensional representation of the position of the tip of this device in the corresponding imaging space intraoperatively. The neuroendoscope also proved useful, since remnant tumor tissues that could not be seen under an operating microscope were frequently recognized near or around the entrance of the tumor cavity, cavernous sinus region and petroclival junction area. The surgeon was able to remove these remnants safely by checking on the neuroendoscope monitor. The tumor was excised completely. The dead space of the tumor cavity was reconstructed using a free rectus abdominis muscle flap. Postoperatively, cerebrospinal fluid leakage and meningitis were recognized, but improved following spinal drainage for one week and intrathecal injection of antibiotic. The oculomotor nerve palsy of the left eye also showed good recovery at one month after the operation. Recently, skull base surgery has undergone considerable developments. Neuroendoscopes and neuronavigators are very helpful for the neurosurgeon in performing skull base tumor surgery safely and with precision, although further instrument modifications are needed.

Chordoma↗

Neuronavigation--first experiences with three different commercially available systems.

Growing interest in neuronavigation also referred to as frameless stereotaxy has led to the development of various navigational devices employing different localization methods. In 152 procedures the authors have used neuronavigation. Cases included 89 intracranial- and 26 skull base tumours, 9 biopsies, 21 vascular and 7 functional procedures on 144 patients since July 1993. In 75 cases the lesions were located in eloquent areas. In 82% (124) MRI, 13% (18) CT and 5% (8) both imaging methods were employed. Three neuronavigational devices with different localization methods were used for the procedures. The Viewing Wand (VW, ISG, Canada), a multijointed arm was used in 101 procedures. In 15 cases the SPOCS (Aesculap, Germany) consisting of cameras detecting infrared light from LED's mounted on instruments and in 51 cases the microscope-integrated MKM (ZEISS, Germany) was investigated, 15 times two systems were used simultaneously. Mean time necessary for preoperative registration was 23 +/- 13 min (VW), 21 +/- 16 min (SPOCS) and 27 +/- 22 min (MKM) respectively. The mean accuracy of registration measured as RMS was 2.9 +/- 1.2 mm (VW), 3.3 +/- 0.9 mm (SPOCS) and 3.1 +/- 1.0 (MKM) respectively. Regarding intraoperative handling the VW was found to be a robust but sometimes bulky and hindering device whereas the SPOCS was more flexible but with the need of unobstructed visibility between cameras and pointers. The MKM without these restrictions required training to get used to handling.

Adolescent↗