Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Multiplex”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

CROPseq-multi: a universal solution for multiplexed perturbation in high-content pooled CRISPR screens.

Forward genetic screens seek to dissect complex biological systems by systematically perturbing genetic elements and observing the resulting phenotypes. While standard screening methodologies introduce individual perturbations, multiplexing perturbations improves the performance of single-target screens and enables combinatorial screens for the study of genetic interactions. Current tools for multiplexing perturbations are limited by technical challenges and do not offer compatibility across diverse screening methodologies, including enrichment, single-cell sequencing, and optical pooled screens. Here, we report the development of CROPseq-multi (CSM), a CROPseq1-inspired lentiviral system to multiplex Streptococcus pyogenes (Sp) Cas9-based perturbations with versatile readout compatibility and high performance for both perturbation and barcode identification. CSM has equivalent per-guide activity to CROPseq and low lentiviral recombination frequencies. Dual-guide CSM libraries are constructed in a single, facile molecular cloning step that facilitates the use of unique molecular identifiers. CSM is compatible with enrichment screening methodologies, single-cell RNA-sequencing readouts, and optical pooled screens. For optical pooled screens, an optimized and multiplexed in situ detection protocol improves barcode counts 10-fold (for mRNA detection), enables detection of recombination events, and reduces the number of sequencing cycles required for decoding by 3-fold relative to CROPseq. CROPseq-multi-v2 (CSMv2) adds compatibility for detection methods based on T7 RNA polymerase in vitro transcription2-5. CSM provides a single system for CRISPR screens that is compatible with individual and combinatorial perturbations, diverse SpCas9-based perturbation technologies, and multiple high-content, single-cell phenotypic readouts.

CRISPR Cas9↗

Turbo-charging crop improvement: harnessing multiplex editing for polygenic trait engineering and beyond.

Multiplex CRISPR editing has emerged as a transformative platform for plant genome engineering, enabling the simultaneous targeting of multiple genes, regulatory elements, or chromosomal regions. This approach is effective for dissecting gene family functions, addressing genetic redundancy, engineering polygenic traits, and accelerating trait stacking and de novo domestication. Its applications now extend beyond standard gene knockouts to include epigenetic and transcriptional regulation, chromosomal engineering, and transgene-free editing. These capabilities are advancing crop improvement not only in annual species but also in more complex systems such as polyploids, undomesticated wild relatives, and species with long generation times. At the same time, multiplex editing presents technical challenges, including complex construct design and the need for robust, scalable mutation detection. We discuss current toolkits and recent innovations in vector architecture, such as promoter and scaffold engineering, that streamline workflows and enhance editing efficiency. High-throughput sequencing technologies, including long-read platforms, are improving the resolution of complex editing outcomes such as structural rearrangements-often missed by standard genotyping-when targeting repetitive or tandemly spaced loci. To fully realize the potential of multiplex genome engineering, there is growing demand for user-friendly, synthetic biology-compatible, and scalable computational workflows for gRNA design, construct assembly, and mutation analysis. Experimentally validated inducible or tissue-specific promoters are also highly desirable for achieving spatiotemporal control. As these tools continue to evolve, multiplex CRISPR editing is poised to become a foundational technology of next-generation crop improvement to address challenges in agriculture, sustainability, and climate resilience.

Gene Editing↗

Mononeuritis multiplex and vasculitis. Association with anti-neutrophil cytoplasmic autoantibody.

Mononeuritis multiplex is known to occur in many illnesses including certain types of systemic vasculitis. Anti-neutrophil cytoplasmic autoantibody (ANCA) has been described in association with Wegener's granulomatosis, polyarteritis nodosa, pauci-immune necrotizing crescentic glomerulonephritis, and so-called ANCA-associated vasculitis. We describe three patients who presented with mononeuritis multiplex and positive tests for ANCA. A careful search revealed underlying vasculitis in two of the three patients. Whereas both respiratory and renal involvement are well known in ANCA-associated vasculitis, to our knowledge the relationship of mononeuritis multiplex and ANCA positivity has not previously been described. The three patients were treated with steroids and oral cyclophosphamide. All demonstrated marked clinical improvement, as well as a decrease or disappearance of the ANCA. Since mononeuritis multiplex may be a presenting symptom of many illnesses, a serological marker may be helpful for early diagnosis and prompt treatment.

Aged↗

Multiple genetic diagnoses from single cells using multiplex PCR: reliability and allele dropout.

We used a multiplex fluorescent PCR system containing seven primer sets on single cells from three different cell types (buccal, corneal and blastomere cells) and more than 3500 heterozygous alleles to investigate reliability and extent of allele dropout in multiplex PCRs at the single cell level. All three cell types gave similarly high reliability, accuracy and allele dropout rates, with similar reliability between singleplex and multiplex PCRs. Allele dropout was also consistent between the three cell types and did not significantly increase as allele size increased. These results indicate that multiplex fluorescent PCR is a reliable and accurate method of obtaining multiple diagnosis (eight chromosomes simultaneously) from single cells and maximizes the information available from single cell analysis.

Alleles↗

Direct genomic multiplex PCR for BRCA1 and application to mutation detection by single-strand conformation and heteroduplex analysis.

Most mutation detection methods are based on analysis of PCR amplified segments and the application of multiplex PCR is one central approach to improving screening efficiency. Genes like the breast-ovarian cancer susceptibility gene BRCA1 pose a difficult challenge to efficient mutation screening because of large coding regions, numerous exons, and complex mutational spectra. The application to BRCA1 of a general approach to effective multiplex PCR is described here. Fifteen triplex PCRs and a single PCR reaction condition were used for amplification of all BRCA1 coding regions and the BRCA1-specific segments from the duplicated promoter region. SSCP/HDX gel analysis of the multiplex products detected mobility distinctions for 34/34 sets of allelic BRCA1 fragments. A novel polymorphism was found, CTTCT(4)CT(10)CT(12) >CT(4)CT(11), a compound deletion in a region beginning at the +33 position of IVS7 and resulting in a net deletion of 15 bp. This change was shown to be one of the common polymorphisms that define the two major haplotypes of the BRCA1-RNU2 region in a large proportion of the world population. A triplex PCR for SSCP detection of this deletion and two other distantly located common polymorphisms may be used to screen haplotype content and facilitate comparison of samples with similar haplotypes in subsequent mutation screening. The approach for robust multiplex amplification is generally applicable and allows rapid development of efficient testing for a wide variety of mutations in any gene(s) encompassing a large coding region or numerous exons and including as many as 50 different genomic PCR products.

Breast Neoplasms↗

Behavioral phenotypic variation in autism multiplex families: evidence for a continuous severity gradient.

Recent genetic investigations of autism have studied multiplex families, typically including families with multiple siblings who meet criteria for a diagnosis of autism. However, little is known about the specific behavioral characteristics of siblings with autism in these multiplex families. We investigated the behavioral phenotypic variability and similarity of 351 siblings with autism in 171 multiplex families using cluster analysis and correlations. The results of cluster analyses showed that the individuals with autism could be characterized on a severity gradient: a continuum based on severity of symptoms and impairment as measured by Autism Diagnostic Interview-Revised (ADI-R) scores, verbal-nonverbal status, and nonverbal IQ scores. Clusters based on scores from the ADI-R for the autism diagnostic criteria of the DSM-IV and nonverbal IQ scores still represented a severity gradient when the effects of verbal-nonverbal status were removed. The severity gradient was shown to be heritable, with a sib correlation of 30% or a heritability of 60%. In summary, in a sample of 171 autism multiplex families, there was no evidence of discrete behaviorally defined subgroups of affected individuals or families characterized by distinct patterns of behavioral symptoms. Rather, the clusters could be characterized along a single, heritable, continuous severity dimension.

Autistic Disorder↗

Brief communication: multiplex X/Y-PCR improves sex identification in aDNA analysis.

This study introduces a polymerase chain reaction (PCR)-based multiplex approach to improve the certainty of molecular sex identification on archaeological skeletal material. We coamplified amelogenin, two X-chromosomal short tandem repeats (STRs) (DXS6789 and DXS9898), and two Y-specific STRs (DYS391 and DYS392). The amplification results of this multiplex approach back each other up, and enable a reliable sex identification. This coamplification of X- and Y-specific markers in a multiplex assay combines the added advantage of positive identification of both female and male individuals with raising the validity of the diagnosis by obtaining multiple data simultaneously. This multiplex system was successfully applied to 3,000-year-old bone material.

Archaeology↗

Clinical demographics of multiplex families with multiple sclerosis. Multiple Sclerosis Genetics Group.

The demographic and clinical characteristics of 89 multiplex families whose affected members meet proposed diagnostic criteria for multiple sclerosis (MS) genetic research are described and compared with 425 sporadic cases of MS and other published collections of MS multiplex families. The proportion of affected multiplex family members who experienced gradual progression of disability from onset (primary progressive MS) is lower than reported by other investigators. Different phenotypes of MS may reflect genetic heterogeneity that may partially explain inconsistencies in the results of genetic linkage studies. Clinical details of affected multiplex family members must be described so that comparisons of genetic results across studies can be properly interpreted.

Adolescent↗

Multiplexed DNA sizing by capillary electrophoresis using entangled polymer solutions and diode array detection.

We developed a method for the analysis of multiplexed double-stranded DNA (dsDNA) samples complexed to various intercalating dyes using entangled polymer solution. A commercial single-column capillary electrophoresis (CE) instrument with diode array detection was used for multiplexed detection of DNA samples by addition of intercalating fluorescent molecules. A Phi X174HinfI and a pGEM DNA ladder (1 mg/mL) were used for the electrophoretic separation of dsDNA fragments ranging in size from 24 to 726 and 36 to 2645 bp, respectively. The results suggested that simultaneous electrophoretic separation of different DNA ladders multiplexed with different dyes could be performed in the same capillary yielding fast DNA sizing separations. CE analysis, which is often overpowered by slab gel in sample throughput, could now overcome this disadvantage by allowing multiplexed sample analysis in a fraction of the time needed for slab gel analysis. The separation efficiency of stained DNA molecules with both dyes were dramatically improved with buffers containing a large cation such as tetrapentylammonium ion (Npe(4) (+)) as the only cation in the buffer.

Bacteriophage phi X 174↗

Fluorescent microsphere-based readout technology for multiplexed human single nucleotide polymorphism analysis and bacterial identification.

Large-scale human genotyping requires technologies with a minimal number of steps, high accuracy, and the ability to automate at a reasonable cost. In this regard, we have developed a rapid, cost-effective readout method for single nucleotide polymorphism (SNP) genotyping that combines an easily automatable single-tube allele-specific primer extension (ASPE) with an efficient high throughput flow cytometric analysis performed on a Luminex 100 flow cytometer. This robust technique employs an ASPE reaction using PCR-derived target DNA containing the SNP and a pair of synthetic complementary capture probes that differ at their 3' end-nucleotide defining the alleles. Each capture probe has been synthesized to contain a unique 25-nucleotide identifying sequence (ZipCode) at its 5' end. An array of fluorescent microspheres, covalently coupled with complementary ZipCode sequences (cZipCodes), was hybridized to biotin-labeled ASPE reaction products, sequestering them for flow cytometric analysis. ASPE offers both an advantage of streamlining the SNP analysis protocol and an ability to perform multiplex SNP analysis on any mixture of allelic variants. All steps of the assay are simple additions of the solutions, incubations, and washes. This technique was used to assay 15 multiplexed SNPs on human chromosome 12 from 96 patients. Comparison of the microsphere-based ASPE assay results to gel-based oligonucleotide ligation assay (OLA) results showed 99.2% agreement in genotype assignments. In addition, the microsphere-based multiplex SNPs assay system was adapted for the identification of bacterial samples by both ASPE and single base chain extension (SBCE) assays. A series of probes designed for different variable sites of bacterial 16S rDNA permitted multiplex analysis and generated species- or genus-specific patterns. Seventeen bacterial species representing a broad range of gram-negative and gram-positive bacteria were analyzed within 16 variable sites of 16S rDNA sequence. The results were consistent with the published sequences and confirmed by direct DNA sequencing.

Alleles↗

A four-channel time domain multiplexer: a cost-effective alternative to multiple receivers.

The concept of simultaneous image acquisition as originally conceived by Hyde has been implemented by Roemer et al. using a multiple receiver system. This article describes an alternative technique that uses time domain multiplexing (TDM) to acquire simultaneous images using a single receiver channel. This method requires few modifications to the existing receiver and has been shown to be equivalent to a true four channel receiver in most applications. The multiplexing technique was implemented and tested on a standard commercial scanner that has also been equipped with a four channel receiver. Signal-to-noise results demonstrate that four independent images can be multiplexed through a single receiver channel with no degradation in image quality. Additionally, spine images that were obtained from a normal volunteer with both a multiplexed single channel receiver and a true four channel receiver system are presented.

Cost-Benefit Analysis↗

Enzyme-linked fluorescent detection for automated multiplex DNA sequencing.

Initiatives to sequence DNA on a large scale have created a need for increased throughput and decreased costs. One scheme for increasing throughput, multiplex sequencing, involves the processing of a mixture of sequencing templates followed by sequential hybridization to reveal the individual sequence ladders on a membrane. Because multiplex sequencing has not been fully automated, and has not seemed automatable, few sequencing efforts have attempted to exploit it. We describe here a scheme for the automation of multiplex sequencing. Probe hybridized to target DNA is detected via spatially localized enzyme-linked fluorescence. Light output is high enough that imaging is possible with simple instrumentation. Direct imaging within an automated hybridization apparatus is made feasible so that the entire process will be automatic once a multiplex membrane is produced. The technique has the potential to increase severalfold the throughput of automated sequencing instruments required for sequencing the human genome.

Base Sequence↗

Linkage analysis with multiplexed short tandem repeat polymorphisms using infrared fluorescence and M13 tailed primers.

The use of short tandem repeat polymorphisms (STRPs) as marker loci for linkage analysis is becoming increasingly important due to their large numbers in the human genome and their high degree of polymorphism. Fluorescence-based detection of the STRP pattern with an automated DNA sequencer has improved the efficiency of this technique by eliminating the need for radioactivity and producing a digitized autoradiogram-like image that can be used for computer analysis. In an effort to simplify the procedure and to reduce the cost of fluorescence STRP analysis, we have developed a technique known as multiplexing STRPs with tailed primers (MSTP) using primers that have a 19-bp extension, identical to the sequence of an M13 sequencing primer, on the 5' end of the forward primer in conjunction with multiplexing several primer pairs in a single polymerase chain reaction (PCR) amplification. The banding pattern is detected with the addition of the M13 primer-dye conjugate as the sole primer conjugated to the fluorescent dye, eliminating the need for direct conjugation of the infrared fluorescent dye to the STRP primers. The use of MSTP for linkage analysis greatly reduces the number of PCR reactions. Up to five primer pairs can be multiplexed together in the same reaction. At present, a set of 148 STRP markers spaced at an average genetic distance of 28 cM throughout the autosomal genome can be analyzed in 37 sets of multiplexed amplification reactions. We have automated the analysis of these patterns for linkage using software that both detects the STRP banding pattern and determines their sizes. This information can then be exported in a user-defined format from a database manager for linkage analysis.

Chromosome Mapping↗

Optimized multiplex PCR: efficiently closing a whole-genome shotgun sequencing project.

A new method has been developed for rapidly closing a large number of gaps in a whole-genome shotgun sequencing project. The method employs multiplex PCR and a novel pooling strategy to minimize the number of laboratory procedures required to sequence the unknown DNA that falls in between contiguous sequences. Multiplex sequencing, a novel procedure in which multiple PCR primers are used in a single sequencing reaction, is used to interpret the multiplex PCR results. Two protocols are presented, one that minimizes pipetting and another that minimizes the number of reactions. The pipette optimized multiplex PCR method has been employed in the final phases of closing the Streptococcus pneumoniae genome sequence, with excellent results.

Algorithms↗

Direct detection of vanA and vanB genes in clinical specimens for rapid identification of vancomycin resistant enterococci (VRE) using multiplex PCR.

Surveillance for vancomycin resistant enterococci (VRE) by culture can be labour intensive and time consuming. We have developed a multiplex polymerase chain reaction (MPCR) which can be performed directly on the clinical specimen. The assay allows sensitive detection of enterococci with vanA - and vanB -mediated resistance to vancomycin. DNA was purified from stool and rectal specimens using the XTRAX(TM)DNA Extraction Kit (Gull Labs). Multiplex PCR amplified vanA and vanB targets were detected using a microtiter plate EIA. Two-hundred specimens were tested by routine culture and MPCR. Culture identified 44 VRE isolates and MPCR detected 38 of the 44 culture positives. Multiplex PCR detected three additional positive VRE specimens missed by culture for a sensitivity and specificity of 86.4 and 98.1%, respectively. When the presence of PCR inhibitors was addressed in the six culture positive/MPCR negative specimens, four additional VRE positive specimens were detected. Performing MPCR on the original specimens and on a 1:10 dilution of all specimens to minimize the effect of inhibitors gave a sensitivity and specificity of 95.5 and 98.1%, respectively. Multiplex PCR with confirmation by microtiter plate hybridization could be completed in 8 h compared with 24-48 h required for culture.

Bacterial Proteins↗

Comparison of multiplex PCR, PCR-ELISA and fluorogenic 5' nuclease PCR assays for detection of plasmid-bearing virulent Yersinia enterocolitica in swine feces.

Swine are implicated as the principal animal reservoir for plasmid-bearing Yersinia enterocolitica (YEP(+)) strains that are pathogenic to humans. To evaluate the utility of the PCR for detection of YEP(+) strains in naturally-contaminated pig feces, samples were first enriched in Irgasan ticarcillin potassium chlorate broth for 48 h at 25 degrees C and then tested by multiplex PCR, PCR-ELISA, and fluorogenic 5' nuclease PCR assays. Three different primer sets for amplification of the ail gene sequences were used in these three assays. Three out of 50 (6%) samples were positive for YEP(+) strains using the multiplex PCR targeting the chromosomal ail (170 bp) and plasmid virF (591 bp) genes. Two of the 3 samples positive by the multiplex PCR were also positive by the PCR-ELISA method using primers targeting the ail gene (425 bp). In contrast, the fluorogenic 5' nuclease PCR assay failed to detect an ail gene sequence (118 bp) in any of the 50 samples. These results indicate that the multiplex PCR was the most reliable and sensitive assay for detecting YEP(+) strains in feces among the three assays evaluated.

Animals↗

Sensitivity of multiplex real-time PCR reactions, using the LightCycler and the ABI PRISM 7700 Sequence Detection System, is dependent on the concentration of the DNA polymerase.

The introduction of multiplex PCR techniques to clinical laboratories has provided a means to streamline assays and to produce multiple results with minimal effort. While this methodology is very beneficial, care must be taken to ensure that reactions are properly optimized to allow for maximum sensitivity. This study was conducted to determine whether the sensitivity of multiplex-real-time PCR assays could be improved by increasing the concentration of DNA polymerase within a reaction. Multiplex reactions were designed to simultaneously detect the human HLA-DQ gene and a sequence from the UL83 region of the CMV genome. Two real-time PCR systems, one utilizing AmpliTaq Gold DNA polymerase and the ABI 7700 Sequence Detection System, and one utilizing FastStart Taq DNA polymerase and the Roche LightCycler were tested. The results indicated that increasing the AmpliTaq Gold concentration from 0.050 to 0.10 U/microl and the FastStart Taq concentration from 0.1875 to 0.375 U/microl increased detection sensitivity from 5,000 to 50 CMV copies per PCR reaction. In separate experiments, commercially prepared mastermixes were utilized for both real-time PCR platforms as per the manufacturer's suggestions or with the addition of supplemental DNA polymerase. In assays designed to detect 4 CMV genome copies per reaction, the addition of 2.5 U of AmpliTaq Gold to TaqMan Universal Mastermix increased the detection rate from 21 to 67%, and the addition of 5 U of FastStart Taq to FastStart DNA Master Hybridization Probes mastermix increased the detection rate from 17 to 56%. These results indicate that increasing the DNA polymerase concentration in multiplex real-time PCR reactions may be a simple way to optimize assay sensitivity.

Cytomegalovirus↗

Real-time multiplex PCR assays.

The ability to multiplex PCR by probe color and melting temperature (T(m)) greatly expands the power of real-time analysis. Simple hybridization probes with only a single fluorescent dye can be used for quantification and allele typing. Different probes are labeled with dyes that have unique emission spectra. Spectral data are collected with discrete optics or dispersed onto an array for detection. Spectral overlap between dyes is corrected by using pure dye spectra to deconvolute the experimental data by matrix algebra. Since fluorescence is temperature dependent and depends on the dye, spectral overlap and color compensation constants are also temperature dependent. Single-labeled probes are easier to synthesize and purify than more complex probes with two or more dyes. In addition, the fluorescence of single-labeled probes is reversible and depends only on hybridization of the probe to the target, allowing study of the melting characteristics of the probe. Although melting curves can be obtained during PCR, data are usually acquired at near-equilibrium rates of 0.05-0.2 degrees C/s after PCR is complete. Using rapid-cycle PCR, amplification requires about 20 min followed by a 10-min melting curve, greatly reducing result turnaround time. In addition to dye color, melting temperature can be used for a second dimension of multiplexing. Multiplexing by color and T(m) creates a "virtual" two-dimensional multiplexing array without the need for an immobilized matrix of probes. Instead of physical separation along the X and Y axes, amplification products are identified by different fluorescence spectra and melting characteristics.

Animals↗