Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Microscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Morphological studies of the spleen in idiopathic portal hypertension (so-called Banti's syndrome without liver cirrhosis) using light microscopy, scanning electron microscopy and histometry.

Morphological changes in the spleens of patients with idiopathic portal hypertension (IPH) were studied and compared with the normal spleen. The study used (1) light microscopy with histometry, (2) scanning electron microscopy (SEM) of the splenic tissue with histometry and (3) SEM of the spleen vascular replica. Histometrical studies by light microscopy showed that the volume of red pulp of IPH was increased in a unit area and to a total of 12 times the normal in the whole spleen. The white pulp was scanty of lymphocytes and decreased in a unit area but it was increased in the whole spleen. SEM of the white pulp of IPH demonstrated many channels formed by reticulum cells and running parallel with each other along the central artery. This finding presumably corresponds to periarterial fibrosis in light microscopy. SEM histometry demonstrated that the venous sinuses of IPH were small but increased in number and occupied the same percentage area in a unit red pulp area as in the normal spleen. The Billroth cord of IPH was narrowed and occupied by thickened reticulum cells, which may cause increased pooling and destruction of blood cells in the enlarged spleen (hypersplenism). SEM of the tissue and vascular replica demonstrated open arterial termination in the Billroth cord in the spleen of IPH as well as in the normal spleen. Venous sinuses in the replica of IPH ran parallel with each other forming bundles with fewer intercommunications than normal.

Adult↗

Rapid detection of biofilms and adherent pathogens using scanning confocal laser microscopy and episcopic differential interference contrast microscopy.

Knowledge of biofilm structure and function has changed significantly in the last few years due to advances in light microscopy. One pertinent example is the use of scanning confocal laser microscopy (SCLM) to visualise corrosion pits caused by the biofilm mosaic footprint on corroding metal surfaces. Nevertheless, SCLM has some limitations as to its widespread use, including cost, inability to observe motile bacteria and eukaryotic grazers within biofilms, and difficulty to scan a curved surface. By contrast, episcopic differential interference contrast (EDIC) microscopy has provided a rapid, real time analysis of biofilms on opaque, curved, natural or man-made surfaces without the need for cover slips and oil. EDIC, coupled with epi-fluorescence (EDIC/EF), microscopy has been used successfully to visualise the 3-D biofilm structure, physiological niches, protozoal grazing and iron biomineralization, and the location of specific pathogens such as Legionella pneumophila, Campylobacter jejuni and Cryptosporidium parvum. These species were identified using gold nanoparticles or fluorophores coupled to monoclonal antibodies or 16S rRNA probes, respectively. Among its many potential uses, the EDIC technique will provide a rapid procedure to facilitate the calibration of the modern generation of biofilm-sensing electrodes.

Animals↗

Identification of feline monocytes and neutrophils as effector cells in antibody-dependent cellular cytotoxicity: sequential analysis, using light microscopy, histochemistry, and scanning electron microscopy.

Feline monocytes and neutrophils functioned as effector cells in antibody-dependent cellular cytotoxicity (ADCC) against antibody-coated chicken erythrocytes. Using light microscopy, effector cell populations were identified in effector-target cell interactions, with further characterization of these identical individual effector cells by histochemical evaluations and scanning electron microscopy. Monocytes and neutrophils, but not lymphocytes, were observed attacking target cells. Carbonyl iron depletion of monocytes and neutrophils from peripheral blood leukocytes caused a marked reduction from a mean of 62% to 3.6% lysis in ADCC as measured by a 4-hour 51Cr release assay. Effector cells functioning in the ADCC reaction were visualized, using sequential analysis and light microscopy, histochemistry, and scanning electron microscopy.

Animals↗

Scanning and transmission electron microscopy and high resolution intravital video-microscopy of capillaries in the mouse exocrine pancreas, with special emphasis on endothelial cells.

Capillaries in the mouse exocrine pancreas were studied by scanning electron microscopy of microvascular corrosion casts, transmission electron microscopy of tissue sections, and high resolution intravital video-microscopy. Two types of capillaries were discerned by corrosion casting. The first type was rather straight, had a constant diameter of 5-6 microns, and its surface showed multiple circumferential furrows. The frequency of such constrictions was less in the second type, which was more undulated and had a diameter of 7-9 microns. In the second type, these constrictions defined bulged areas of the capillary cast. Corresponding tissue sections also showed two types of capillaries, fenestrated and non-fenestrated capillaries. Microtubules were abundant in all capillary endothelial cells, whereas bundles of microfilaments were scarce. Microtubules were arranged along the long axis of endothelial cells as well as parallel to endothelial cell border regions. Endothelial cells were joined by intermediate junctions along cell borders running both circumferentially and longitudinally. Flow reversal in capillaries and spontaneous endothelial contractions were documented in vivo. Endothelial cells bulged into the lumen, either at their nuclear region or distant from it. Spontaneous contraction of pericytes was not observed. These results suggest that contraction of capillaries is carried out by endothelial cells, representing an autonomous flow regulatory device. Capillary contraction in exocrine pancreas may be influenced by blood-borne agents, probably by those released in Langerhans islets.

Animals↗

Effects of acetone, methanol, or paraformaldehyde on cellular structure, visualized by reflection contrast microscopy and transmission and scanning electron microscopy.

The authors recently showed variable subcellular immunoreactivity of the Bcl-2 and Bax proteins after fixation of cell monolayers with acetone, methanol, or paraformaldehyde (PF) followed by methanol (PF/methanol). Here, the authors demonstrate by reflection contrast microscopy and transmission electron microscopy that acetone or methanol fixation result in complete loss of integrity of intracellular structures in contrast with PF or glutaraldehyde fixation. Scanning electron microscopy revealed poor preservation of plasma membrane integrity after fixation in acetone or methanol. Fixation with PF before methanol reduced damage to intracellular and plasma membranes. In addition, Western blot analysis demonstrated loss of Bcl-2 and Bax protein during acetone or methanol fixation, whereas PF fixation before methanol permeabilization markedly reduced this loss. For studies on the intracellular localization of soluble or unknown types of antigen, the authors discourage the use of acetone and methanol as single fixatives.

Acetone↗

A rapid and simple technique for correlating light microscopy, transmission and scanning electron microscopy of fixed tissues in Epon blocks.

A simplified and standardized technique for close correlation between light microscopy (LM), transmission electron microscopy (TEM) and scanning electron microscopy (SEM) is described. Perfusion and immersion fixed tissue specimens were embedded in Epon 812 and cut for conventional LM and TEM. The Epon blocks with remaining tissue were thereafter treated with epoxy solvent (ethanol-NaOH solution) for partial epoxy resin removal only (dissolving rate approx 33 microns/h). The blocks with partially blotted tissue specimens were then critically point dried and gold coated for SEM. This method, in an easy way, allows repeated observations with LM, TEM and SEM with preserved fine structure and exact correlation. Since the technique is so simple and there is no need for special equipment the method can easily be adopted in all laboratories with basic SEM standards.

Animals↗

Concerted use of immunologic and ultrastructural analyses in diagnostic medicine: immunoelectron microscopy and correlative microscopy.

Electron microscopy (EM) is a valuable tool in diagnostic medicine, and in some cases, can be enhanced by immunological methods. A major medical application of EM, diagnostic virology, can frequently be augmented by employment of immunological reagents. Three immunoelectron microscopy (IEM) methods, aggregation, coating, and gold labeling, provide means for serotyping viruses; aggregation by antibody can also be used to concentrate viruses in dilute suspension or to serotype them. As a research tool, IEM can be useful in studying the relationship of various pathogen proteins to the infected cells or tissues. Delineating the subcellular location of viral components can yield information about how virions are constructed, and hence, suggest methods and compounds for inhibiting that process. Conversely, labeling virus-infected cells with antibodies against various cell receptors and proteins can yield information about the association of the proteins with budding virions. Another research example is the identification by immunological staining of virus-infected cells for subsequent ultrastructural identification of the specific cell type involved. Electron microscopy and immunolabeling methods are also useful in the diagnosis of immune complex disorders, including various forms of postinfectious immune complex glomerulonephritis. Precise analysis of immune complex deposits can be accomplished by using EM to pinpoint their location and immunohistology to probe their composition. Finally, a variety of optical microscopic techniques, including some involving immunofluorescent labeling, can be used to identify areas of interest in inhomogeneous tissues for further study by EM.

Child↗

Chronology of cellular alterations during 7-ketocholesterol-induced cell death on A7R5 rat smooth muscle cells: analysis by time lapse-video microscopy and conventional fluorescence microscopy.

BACKGROUND: Time-lapse video microscopy was used to determine whether mitochondrial and nuclear changes (decrease in mitochondrial transmembrane potential, condensation, and/or fragmentation of the nuclei, morphologic features typical of apoptosis) occurring during 7-ketocholesterol-induced cell death on A7R5 rat smooth muscle cells took place before or after the loss of cell adhesion. In addition, changes in actin organization were followed by conventional fluorescence microscopy. METHODS: Morphologic, functional, and spatial changes at the mitochondrial level were investigated with 3,3'-dihexyloxacarbocyanine iodide and/or MitoTracker Red, and nuclear morphology was characterized by staining with Hoechst 33342. Actin fibers, which are major components of the filament network of the cytoskeleton, were visualized with phalloidin linked to fluorescein. The numbers of adherent and nonadherent cells were determined by cell counting. RESULTS: 7-Ketocholesterol-induced cell death was associated with a rapid alteration of actin fibers, a loss of intercellular junctions, and cell shape modifications. Analysis of mitochondrial transmembrane potential showed successively a hyperpolarization and a more or less pronounced progressive decrease followed by a dramatic drop associated with an increase in Hoechst 33342 staining, reflecting chromatin condensation and morphologic changes in the nuclei. CONCLUSIONS: During cell death induced by 7-ketocholesterol in A7R5 rat smooth muscle cells, the different methods of microscopy allowed us to establish that alterations of actin fibers and mitochondrial dysfunctions occurred before condensation and/or fragmentation of the nuclei, which preceded the loss of cell adhesion.

Actins↗

Three-dimensional morphology of cerebellar climbing fibers. A study by means of confocal laser scanning microscopy and scanning electron microscopy.

The intracortical pathway of cerebellar climbing fibers have been traced by means of scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM) to study the degree of lateral collateralization of these fibers in the granular Purkinje cell and molecular layers. Samples of teleost fish were processed for conventional and freeze-fracture SEM. Samples of hamster cerebellum were examined by means of CLSM using FM4-64 as an intracellular stain. High resolution in lens SEM of primate cerebellar cortex was carried out using chromium coating. At scanning electron and confocal laser microscopy levels, the climbing fibers appeared at the white matter and granular layer as fine fibers with a typical arborescence or crossing-over branching pattern, whereas the mossy fibers exhibited a characteristic dichotomous bifurcation. At the granular layer, the parent climbing fibers and their tendrils collaterals appeared to be surrounding granule and Golgi cells. At the interface between granule and Purkinje cell layers, the climbing fibers were observed giving off three types of collateral processes: those remaining in the granular layer, others approaching the Purkinje cell bodies, and a third type ascending directly to the molecular layer. At this layer, retrograde collaterals were seen descending to the granular layer. By field emission high-resolution SEM of primate cerebellar cortex, the climbing fiber terminal collaterals were appreciated ending by means of round synaptic knobs upon the spines of secondary and tertiary Purkinje cell dendrites.

Animals↗

Confocal light microscopy and scanning electron microscopy of the human eye lens.

The potential of confocal light microscopy (CLM) for in vivo observation of pathology in the anterior pole of the eye lenses was evaluated by performing an in vitro study of human lenses comparing this type of microscopy with scanning electron microscopy (SEM). In vitro CLM showed high resolution images of the epithelium which would enable early detection of pathology and easily allows cell counting and estimating cell size. Superficial lens fibres are well visualised and low and high frequency bands as well as vacuolar elements were easily detected. SEM observations fully supported the CLM observations. This study shows that CLM has the potential to become a useful tool for detecting lens changes, after suitable adaptation for clinical use.

Adult↗

[Micromorphological findings in jaw bone after radiotherapy. Confocal laser scanning microscopy and fluorescence darkfield microscopy studies].

Early radiation effects on human bone may lead to osteoradionecrosis (ORN). Direct bone cellular lesions [28] as well as fibrous degeneration of blood vessels [21] are considered to be pathologically relevant. Only few data on initial subclinical radiation effects are available. Patients were grouped according to the dose of radiation and clinical findings. Group 1: sound human bone of lower jaw, mostly collected during orthodontic surgery (n = 10 patients); group 2: specimens of lower jaw from patients with ORN (n = 12 patients); group 3: specimens of lower jaw from patients with head and neck cancer who were preoperatively treated with 36 Gy radiation; group 4: specimens of lower jaw from patients with head and neck cancer (n = 9) who were treated with 60-70 Gy radiation. Specimens were studied by confocal laser scanning microscopy (CLSM), by conventional light microscopy (DL) and by fluorescence darkfield microscopy (DFM) after bisbenzimide staining (H 33258) of the viable cellular nuclei. For the correlating study of identical areas in CLSM and DL the specimens were prepared according to the sawing and grinding technique [8]. All the radiated bony specimens, regardless of the dose of radiation, showed areas of extensive or total loss of vitality of the osteocytes. This finding was also evident after 36 Gy and a short interval between radiation and sample collection (group 3). Additionally, in CLSM micromorphologic lesions of the lamellate structure were seen. With these results we can confirm the loss of vitality of the osteocytes as an initial radiation effect as described earlier [10, 23, 28]. In addition to these findings, alteration of the lamellate microstructure was found in the early phase after radiation. The functional and mechanical significance of these findings should be the subject of further studies.

Bone and Bones↗

Interactions of elastic and rigid vesicles with human skin in vitro: electron microscopy and two-photon excitation microscopy.

Interactions between vesicle formulations and human skin were studied, in vitro, in relation to their composition and elasticity. The skin ultrastructure was investigated using transmission electron microscopy (TEM), freeze-fracture electron microscopy (FFEM) and two-photon fluorescence microscopy (TPE). The main difference between the vesicle formulations was their elasticity. Elastic vesicle formulations contained bilayer forming surfactants/lipids and single-chain surfactant octaoxyethylenelaurate-ester (PEG-8-L), whereas rigid vesicles contained bilayer surfactants in combination with cholesterol. TEM results showed three types of interactions after non-occlusive application of elastic PEG-8-L containing vesicle formulations on human skin: (1) the presence of spherical lipid structures containing or surrounded by electron dense spots; (2) oligolamellar vesicles were observed between the corneocytes in the upper part of the stratum corneum; and (3) large areas containing lipids, surfactants and electron dense spots were observed deeper down into the stratum corneum. Furthermore, after treatment with vesicles containing PEG-8-L and a saturated C12-chain surfactant, small stacks of bilayers were found in intercellular spaces of the stratum corneum. Rigid vesicles affected only the most apical corneocytes to some extent. FFEM observations supported the TEM findings. Major morphological changes in the intercellular lipid bilayer structure were only observed after treatment with PEG-8-L containing elastic vesicles. TPE showed a distinct difference in penetration pathways after non-occlusive application of elastic or rigid vesicles. After treatment with elastic vesicles, thread-like channels were formed within the entire stratum corneum and the polygonal cell shape of corneocytes could not be distinguished. Fluorescent label incorporated in rigid vesicles was confined to the intercellular spaces of the upper 2-5 micrometer of the stratum corneum and the cell contours could still be distinguished.

Freeze Fracturing↗

Design of functionalized lipids and evidence for their binding to photosystem II core complex by oxygen evolution measurements, atomic force microscopy, and scanning near-field optical microscopy.

Photosystem II core complex (PSII CC) absorbs light energy and triggers a series of electron transfer reactions by oxidizing water while producing molecular oxygen. Synthetic lipids with different alkyl chains and spacer lengths bearing functionalized headgroups were specifically designed to bind the Q(B) site and to anchor this large photosynthetic complex (240 kDa) in order to attempt two-dimensional crystallization. Among the series of different compounds that have been tested, oxygen evolution measurements have shown that dichlorophenyl urea (DCPU) binds very efficiently to the Q(B) site of PSII CC, and therefore, that moiety has been linked covalently to the headgroup of synthetic lipids. The analysis of the monolayer behavior of these DCPU-lipids has allowed us to select ones bearing long spacers for the anchoring of PSII CC. Oxygen evolution measurements demonstrated that these long-spacer DCPU-lipids specifically bind to PSII CC and inhibit electron transfer. With the use of atomic force microscopy (AFM) and scanning near-field optical microscopy (SNOM), it was possible to visualize domains of PSII CC bound to DCPU-lipid monolayers. SNOM imaging has enabled us to confirm that domains observed by AFM were composed of PSII CC. Indeed, the SNOM topography images presented similar domains as those observed by AFM, but in addition, it allowed us to determine that these domains are fluorescent. Electron microscopy of these domains, however, has shown that the bound PSII CC was not crystalline.

Diuron↗

Assembly of chromatin fibers into metaphase chromosomes analyzed by transmission electron microscopy and scanning electron microscopy.

The higher-order assembly of the approximately 30 nm chromatin fibers into the characteristic morphology of HeLa mitotic chromosomes was investigated by electron microscopy. Transmission electron microscopy (TEM) of serial sections was applied to view the distribution of the DNA-histone-nonhistone fibers through the chromatid arms. Scanning electron microscopy (SEM) provided a complementary technique allowing the surface arrangement of the fibers to be observed. The approach with both procedures was to swell the chromosomes slightly, without extracting proteins, so that the densely-packed chromatin fibers were separated. The degree of expansion of the chromosomes was controlled by adjusting the concentration of divalent cations (Mg2+). With TEM, individual fibers could be resolved by decreasing the Mg2+ concentration to 1.0-1.5 mM. The predominant mode of fiber organization was seen to be radial for both longitudinal and transverse sections. Using SEM, surface protuberances with an average diameter of 69 nm became visible after the Mg2+ concentration was reduced to 1.5 mM. The knobby surface appearance was a variable feature, because the average diameter decreased when the divalent cation concentration was further reduced. The surface projections appear to represent the peripheral tips of radial chromatin loops. These TEM and SEM observations support a "radial loop" model for the organization of the chromatin fibers in metaphase chromosomes.

Calcium↗

Electron microscopy: use of transmission and scanning electron microscopy to study cells in culture.

Standard techniques for electron microscopy were developed for tissues dissected from animals. Optimal methods for electron microscopy of cells in culture are different. This chapter describes methods for processing cells grown on plastic or in suspension. Both transmission and scanning electron microscopy are discussed. The focus is on the procedures for fixation, dehydration, embedding, and staining, which will help the reader to obtain superior electron micrographs of cultured cells.

Animals↗

Platelet-derived microparticles on synthetic surfaces observed by atomic force microscopy and fluorescence microscopy.

Platelet activation on a thrombogenic surface includes the release of membrane-derived microparticles that provide catalytic sites for blood coagulation factors. Here, we describe a quantitative investigation on the production and dimensions of platelet-derived microparticles observed on glass and polyethylene under aqueous conditions, using atomic force microscopy (AFM) and complementary fluorescence microscopy. The results show that contact-activated platelet microparticles are not evenly distributed over a thrombogenic surface, but in clusters in close proximity to adherent platelets. The microparticles are localized near the platelet periphery, and in some cases appear to emanate from platelet pseudopodia, suggesting that formation may result from vesiculation of the pseudopodia. The microparticles measured 125 +/- 21 nm (n = 73) in the x-y dimensions and 5.2 +/- 3.6 nm in height. The results compared closely with 125 +/- 22 nm width and 4.1 +/- 1.6 nm height obtained for control preparations of thrombin activated microparticles, that were filtered and deposited on glass. Large differences between the measured widths and heights of adsorbed microparticles suggest that platelet microparticles may undergo spreading after attachment to a surface. The adsorbed microparticles expressed platelet membrane receptor GPIIb/IIIa, and many expressed the platelet activation marker P-selectin as determined by fluorescence microscopy. The high number distribution of procoagulant microparticles per unit area of surface compared with platelets suggests that platelet-derived microparticles provide a mechanistic route for amplifying thrombus formation on a thrombogenic surface.

Biocompatible Materials↗

Thermal balloon endometrial ablation: safety aspects evaluated by serosal temperature, light microscopy and electron microscopy.

OBJECTIVES: Thermal balloon endometrial ablation is a new method for treating menorrhagia. The technique appears to be less difficult compared to standard hysteroscopic ablation techniques and to be significantly safer. The influence into the uterine wall of the thermal balloon ablation procedure was investigated with special reference to the ability of total destruction of the endometrium and the thermal action on the myometrium and the serosa. STUDY DESIGN: Temperatures were measured at the uterine serosal surface during thermal balloon endometrial ablation for 8-16 min in eight patients. After subsequent hysterectomy the extent of thermal damage into the myometrium was assessed by light and electron microscopy. RESULTS: The highest temperature measured on the uterine serosa was 39.1 degrees C. Coagulation of the myometrium adjacent to the endometrium could be demonstrated by light microscopy in all patients, with a maximum depth of 11.5 mm. By electron microscopy no influence of heat could be demonstrated beyond 15 mm from the endometrial surface. CONCLUSION: Up to 16 min of thermal balloon endometrial ablation therapy can destroy the endometrium and the submucosal layers. The myometrium is only coagulated to a depth where full thickness necrosis or injury is unlikely.

Adult↗

Investigation of microcontact transfer of proteins from a selectively plasma treated elastomer stamp by fluorescence microscopy and force microscopy.

Selective plasma treatment of the recessed regions of the elastomer stamps is shown to alter the resultant protein patterns. Fluorescence microscopy is demonstrated to be an excellent tool to discriminate between regions of microcontact printed fluorescent dye-labelled albumin in polystyrene. Atomic force microscopy and shear force microscopy are used to provide high-resolution images of the patterned protein layers. The formation and characteristics of the patterns formed by these alternative strategies is discussed.

Animals↗