Search PubMedSearch

SEARCH · Search PubMed

Results for “Measurement reliability”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

718 records · Page 5Linked to original sources

A versatile reversed-phase liquid chromatography charged aerosol detection method for streamlined monitoring of QS-21 content and stability in liposomal adjuvant formulations.

Identifying and quantifying an active adjuvant along with its degradants in drug formulations is essential for ensuring the safety and efficacy of the drug product. QS-21 is a potent adjuvant that is being evaluated in several clinical trials and is currently formulated in licensed vaccines that protect against shingles, malaria, and RSV. In aqueous environments, QS-21 is subject to hydrolytic degradation that is influenced by pH and temperature, resulting in the formation of a degradant known as QS-21 Hydrolyzed Product, QS-21 HP, which can occur during manufacturing and/or prolonged storage. The intact QS-21 and QS-21 HP induce distinct immune response profiles, making it critical to monitor the degradation of QS-21 in vaccine adjuvant formulations. To date, there has been a paucity of reliable assays for QS-21, its isomers, and degradant QS-21 HP in liposomal adjuvant formulations available that can be transferred seamlessly in quality control (QC) environments. Herein, we introduce a simple and QC-friendly liquid chromatography coupled to a charged aerosol detector (LC-CAD) enabled by stationary phase screening combined with in silico method development optimization. The method exploits 2.7&#xa0;&#x3bc;m fused-core phenyl hexyl particles, ensuring its versatility in standard and ultra-high pressure LC systems. This approach demonstrates a high correlation between predicted retention time (RT) and experimental outcomes with overall &#x2206;RT&#xa0;<&#xa0;4%. In addition, this assay shows great linearity, precision, specificity, and accuracy to advance process development characterization of new vaccine formulations.

Liposomes

Gonadal function and fertility outcomes after orchiopexy versus orchiectomy for testicular torsion: A systematic review and meta-analysis.

PURPOSE: To review the early and late changes in hormonal profiles, semen parameters, and clinical outcomes in patients treated with orchiopexy versus orchiectomy for testicular torsion. METHODS: A systematic search was conducted across MEDLINE, Scopus, Web of Science, Cochrane Library, and other databases, following PRISMA guidelines. PRIMARY OUTCOMES: FSH, LH, testosterone, inhibin-B, and semen parameters. Quality was assessed using the Newcastle-Ottawa Scale. Certainty of evidence was evaluated using the GRADE framework. Statistical analysis was performed using the random-effects model. RESULTS: Eleven studies involving 538 participants (197 orchiectomy, 341 orchiopexy) were included. Orchiectomy was associated with a significant increase in FSH (SMD: 1.63, P < 0.0001) and LH (SMD: 1.31, P < 0.0001) compared to orchiopexy. However, testosterone (MD: 0.31 ng/mL; P = 0.4) and inhibin-B (SMD: -0.14; P = 0.87) levels were comparable between groups. Regarding semen parameters, orchiectomy resulted in a significant reduction in sperm concentration (MD: -18 million/mL, P = 0.01). No significant differences were found in sperm count (MD: 13.9 million; P = 0.43), normal morphology (MD: 4.97%; P = 0.12), or total motility (MD: 4.05%; P = 0.49). The pooled rate for ipsilateral atrophy following orchiopexy was 38%, which likely depends on ischemia duration. CONCLUSION: Surgical choice in testicular torsion does not significantly affect the overall hormonal balance or most semen parameters due to compensatory mechanisms of the hypothalamic-pituitary-gonadal axis. Clinical decisions should consider individual case factors, as we lack reliable data on subsequent paternity rates.

Male

Safety and Stability of a Combined C2 Screw Placement Strategy With Vertebral Artery Mobilization.

BACKGROUND: Although C2 pedicle screws are considered the gold standard for atlantoaxial fixation, the optimal fixation strategy for patients with high-riding vertebral arteries (HRVA) or narrow C2 pedicles (NC2P) remains controversial because of the increased risk of vertebral artery injury and the limitations of alternative fixation techniques. OBJECTIVE: To evaluate the safety, stability, and clinical efficacy of an individualized C2 screw fixation strategy incorporating vertebral artery mobilization for complex upper cervical anatomy. METHODS: A retrospective study was conducted in 312 patients who underwent C2 fixation between 2017 and 2025. Patients were categorized according to fusion method, screw laterality, and VA transposition requirement. Bone fusion rates and screw accuracy (Gertzbein-Robbins grading) were compared across groups using &#x3c7;2, Fisher's exact, and multivariate logistic regression analyses to control confounders. RESULTS: All procedures were successfully completed without permanent neurovascular injury. At 6&#x2009;months, the fusion rate with an atlantoaxial fusion cage was significantly higher than with interlaminar bone grafting (92.3% vs. 51.0%, p&#x2009;<&#x2009;0.001). Unilateral C2 pedicle screw fixation combined with a contralateral alternative screw achieved comparable stability to bilateral fixation (p&#x2009;>&#x2009;0.05). Screw placement accuracy was 100% clinically acceptable in normal anatomy and 60% in cases requiring VA mobilization, with no VA injury or blood flow compromise. CONCLUSION: The proposed multi-strategy C2 screw placement protocol-integrating fusion cage support and VA mobilization-achieves superior fusion, reliable fixation, and high safety, even in anatomically challenging conditions. This approach provides a reproducible and versatile solution for C2 instrumentation in complex craniovertebral junction surgery.

Humans

Genomic determinants underlying biogenic amine detoxification phenotypes in food-associated lactic acid bacteria: Mechanism, evolutionary origin, and relevance to fermented food safety.

Biogenic amines (BAs) are toxic metabolites that accumulate in fermented foods and pose significant food safety concerns. Although several lactic acid bacteria (LAB) have previously been reported to exhibit strain-specific BA-degrading phenotypes, the genetic determinants underlying these activities have remained largely uncharacterized. Here, we analyzed 8251 LAB genomes to validate BA-degrading phenotypes. We predicted five BA-associated genes, including two direct biogenic amine-degrading genes (BADGs), mco and patA, and three polyamine-modifying genes (PMGs), speG, paiA, and bltD. Among BADGs, mco was broadly distributed across LAB and strongly enriched across food-associated niches. patA, organized within a conserved potD-glnB-potABC-patA cassette, is a putative, functionally distinct BADG in LAB, revealing a nitrogen-responsive polyamine uptake-catabolism module. Phylogenomics, phylogenetic reconciliation, and synteny analysis established that all five genes entered the LAB through episodic horizontal gene transfer followed by lineage-specific fixation. GC compositional bias and mobile genetic element association further corroborated the horizontal origin of the two BADGs. Structural analysis confirmed the conservation of catalytic core residues of BADGs across LAB, indicating strong purifying selection. Phenotype-to-genotype correlation with experimentally reported LAB suggested mco as a reliable genomic predictor of degrading phenotype. Integration of degradation and biosynthetic profiles predicted multiple LAB species capable of both synthesizing and degrading BA, along with 1823 genomes with degradation potential but lacking detectable BA biosynthesis genes. This study provides the first large-scale genome framework linking BA-degrading phenotypes with their genetic determinants in LAB and offers a rational basis for selecting BA-detoxifying strains for fermented food applications.

Biogenic Amines

Acceptability of capillary point-of-care testing: a systematic review.

OBJECTIVE: To identify and synthesise evidence on the acceptability and perceived experience of finger-prick point-of-care testing (POCT) among patients and clinicians across healthcare settings. DESIGN: Systematic review conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA 2020) guidelines. DATA SOURCES: Medline, Embase, PsycInfo, CINAHL, Cochrane and Web of Science were searched from inception to January 2024 and re-run in July 2025, supplemented by citation tracking of relevant studies. ELIGIBILITY CRITERIA: Studies reporting patient and clinicians' experiences, perceptions, satisfaction or acceptability relating to finger-prick POCT for any health condition or blood parameter were eligible. Quantitative, qualitative and mixed-methods designs were included. DATA EXTRACTION AND SYNTHESIS: Data were extracted independently by two reviewers and synthesised using thematic analysis and narrative synthesis. Methodological quality was appraised using the Mixed-Methods Appraisal Tool. RESULTS: 21 studies met the inclusion criteria, encompassing 9128 participants (17 quantitative, 3 qualitative, 1 mixed methods). Across diverse clinical contexts, finger-prick POCT was reported as generally acceptable, less distressing and perceived as a convenient alternative to venous sampling in comparative studies. Thematic synthesis identified two major themes: (1) enhancing the patient-clinician relationship through improved engagement, communication and understanding of care and (2) clinical implications of finger-prick POCT on clinicians' workflow, confidence and skill acquisition. Finger-prick POCT was perceived to promote personalised consultations, enable immediate discussion of results and streamline decision-making. Clinicians highlighted its potential to expand task sharing, improve efficiency and strengthen continuity of care, although concerns regarding training, reliability and quality assurance were identified. CONCLUSIONS: Finger-prick POCT is generally acceptable to patients and clinicians, improving comfort, convenience, engagement and perceived efficiency. Implementation should prioritise training, infrastructure and quality assurance frameworks to maximise clinical and experiential benefits. PROSPERO REGISTRATION NUMBER: CRD42024512130.

Humans

A systematic literature review on low-grade myofibroblastic sarcoma of the trunk.

BACKGROUND: Low-grade myofibroblastic sarcoma (LGMS) is a rare malignant mesenchymal tumor, with primary trunk involvement being particularly uncommon. Due to its rarity, associated diagnostic challenges, and variability in management, a comprehensive evaluation of the available evidence is required. This study aims to systematically review the clinical characteristics, treatment strategies, and outcomes of truncal LGMS. METHODS: A systematic literature search was conducted using PubMed, Web of Science, and Embase for articles published from January 1998 to January 2026. The review included full-text articles involving patients with a pathologically confirmed diagnosis of truncal LGMS. The collected data included patient demographics, tumor features, treatment modalities, recurrence, and follow-up status. RESULTS: Of the 404 studies initially identified, 30 studies involving 59 patients with pathologically confirmed truncal LGMS met the inclusion criteria. Outcome analyses of therapeutic management and clinical course included 45 patients with complete follow-up data, including 42 surgically treated patients and 3 non-surgically managed patients. The final evidence base consisted solely of retrospective studies and case reports. No prospective studies or randomized controlled trials were identified. Consequently, a descriptive statistical analysis was conducted instead of a meta-analysis. CONCLUSION: Current evidence indicates that wide excision with negative margins may be a reasonable primary treatment option for truncal LGMS, with case-based reports showing numerically lower recurrence after wide excision, although the evidence is limited and potentially confounded by multiple factors. Radiotherapy or chemotherapy may be considered only on a highly individualized basis for selected unresectable, recurrent, metastatic, anatomically constrained, or margin-positive cases. Given the very limited sample size and heterogeneous treatment indications across published cases, treatment efficacy cannot be reliably estimated from the available data. Prolonged long-term regular follow-up is recommended for all patients, considering the risk of late recurrence.

Humans

Evidence-based insights into medial pedicle reduction mammaplasty: A systematic review and meta-analysis.

BACKGROUND: Breast reduction relieves the physical and psychosocial burden of macromastia. Medial pedicle reduction mammaplasty may enhance vascular reliability, preserve nipple-areola complex (NAC) sensation, and sustain upper pole fullness, even in large-volume reductions. The purpose of this study was to assess the outcomes of medial pedicle breast reduction. METHODS: A search across ScienceDirect, Cochrane, and PubMed was conducted. Included studies reported on perioperative outcomes and complications of medial pedicle breast reduction. Data on demographics, surgical variables, complications, sensory recovery, volumetric changes, and patient satisfaction were extracted. Proportion meta-analysis was performed, and odds ratios were calculated for comparison with inferior pedicle breast reduction. RESULTS: Twenty-five studies comprising 1033 patients met the inclusion criteria. Mean BMI ranged from 27 to 42&#xa0;kg/m2, with mean resection weights between 412 and 3828&#xa0;g. Mean surgical times ranged from 104 to 204&#xa0;min. Pooled complication rates were low: infection 1%, seroma 1%, hematoma 1%, fat necrosis 2%, NAC necrosis 1%, dehiscence 8%, and reintervention 5%. Odds of complications did not differ significantly from inferior pedicle reductions. NAC sensation typically recovered by 6-12 months, with no long-term deficits. Volumetric analyses demonstrated stable breast shape after the first postoperative year, with superior upper pole tissue maintained. Patient satisfaction ranged 75-100%, with higher ratings for scar appearance and overall aesthetics in medial pedicle reductions. CONCLUSION: Medial pedicle breast reduction is a well-established and reproducible technique, preserving NAC sensation, achieving stable long-term shape, and enhancing upper pole fullness. It offers satisfactory aesthetic outcomes compared to other traditional methods, even in large-volume reductions.

Humans

Screening of Estrogenic and Antiestrogenic Effects of Estradiol, Bisphenol A, and Fulvestrant Using 2D and 3D Breast Cancer Cell Systems With a Luciferase Reporter Gene Assay.

Endocrine-disrupting chemicals (EDCs) like bisphenol A (BPA) pose health risks by interfering with hormones. This study develops and utilizes in&#xa0;vitro 2D and 3D cell models to evaluate the estrogenic and antiestrogenic properties of compounds. Human breast cancer cell lines T47D and MCF7, stably transfected with a luciferase reporter gene (ERE-LUC), were first compared in 2D. Due to the significantly higher sensitivity and responsiveness observed in the T47D line during preliminary 2D screenings, this cell line was exclusively selected for the development of the 3D spheroid model. Cells were treated with 17&#x3b2;-estradiol (E2), BPA, and Fulvestrant (FUL) to assess cell viability and luciferase activity. In 2D models, T47D ERE-LUC cells showed higher responsiveness than MCF7 ERE-LUC, which failed to show significant luciferase induction with E2. In the 3D T47D model, cells exhibited significant and robust changes in luciferase activity in response to E2 and BPA, highlighting the enhanced fidelity of 3D cultures in replicating tissue conditions compared to their 2D counterparts. The study highlights the effectiveness of 3D models over 2D in evaluating estrogenic activity. Specifically, the 3D T47D ERE-LUC system serves as a superior, sensitive, and reliable platform for screening EDCs, offering benefits in cost, data speed, and reduced in&#xa0;vivo reliance.

Humans

Artificial intelligence for anticancer drug discovery from natural products of macroalgae and sponges: A systematic review.

Marine natural products (MNPs) from macroalgae and marine sponges have inspired clinically important anticancer agents, including the cytarabine pharmacophore and the eribulin scaffold, while cyanobacterial dolastatin chemistry supplies the auristatin payloads of several marine-inspired antibody-drug conjugates (ADCs) such as brentuximab vedotin. Artificial intelligence (AI) methods, encompassing both classical machine learning (ML) with hand-engineered features and modern deep learning (DL) with many-layered neural networks, are increasingly supporting key decisions in natural-product anticancer drug discovery, including bioactivity prediction, target identification, absorption, distribution, metabolism, excretion and toxicity (ADMET) filtering, generative analogue design, and the selection of preclinical candidates. DL architectures relevant to this field include graph neural networks, transformer-based molecular generators, diffusion models for protein-ligand docking, and convolutional networks for mass spectrometry, while classical ML contributes interpretable fingerprint-based bioactivity models and molecular networking for dereplication. This review follows a systematic literature review methodology to organize the landscape of AI methods now applied to MNP anticancer discovery, distinguishing ML and DL approaches where relevant, situating them within the chemical context of macroalgal and sponge-derived oncology leads, and critically examining published case studies, including validation level (computational, in vitro, in vivo, clinical). The principal bottleneck for medical translation has shifted partly from algorithmic capability toward data infrastructure and experimental validation. Sparse, heterogeneous, and taxonomically biased bioactivity records limit what current models can learn and reduce the reliability of AI-prioritized candidates entering the preclinical pipeline. A roadmap is proposed that prioritizes open MNP-specific benchmarks, symbiont-aware modeling, and active learning loops with synthesizability and ADMET constraints. These AI workflows may accelerate the prioritization of marine-derived anticancer leads and support earlier, more evidence-based translational decisions in oncology drug development.

Biological Products

Assay-dependent variability in peptide biomarker quantification: experimental evidence from renalase in chronic kidney disease.

BACKGROUND: Renalase is a promising biomarker for kidney disease, but published levels vary widely between studies. We hypothesised that variability in commercial enzyme-linked immunosorbent assays (ELISAs) kits and matrix effects (serum vs plasma) drive these inconsistencies. METHODS: Paired serum and plasma samples from 56 participants (28 chronic kidney disease (CKD) stages 2-5, 28 healthy controls) were tested using three commercial renalase ELISAs (BTLAB, Cloud-Clone, EIAab). We assessed intra-assay precision, inter-assay agreement (Spearman's rank correlation and Bland-Altman analysis on log10-transformed values), matrix effects, and associations with estimated glomerular filtration rate (eGFR). Diagnostic performance was evaluated by Receiver operating characteristic (ROC) analysis. RESULTS: Inter-assay renalase concentrations differed markedly (up to orders of magnitude), with weak inter-assay correlations (r&#x2009;&#x2264;&#x2009;0.25). Bland-Altman analyses revealed large, systematic biases between kits. Only the BTLAB assay showed consistent serum/plasma agreement, a significant correlation with eGFR (&#x3c1;&#x2009;&#x2248;&#x2009;0.32-0.42, p&#x2009;<&#x2009;0.05), and moderate discriminatory performance for CKD in serum (AUC = 0.70) and plasma (AUC = 0.68). Cloud-Clone and EIAab produced divergent results and strong matrix-dependent biases. CONCLUSIONS: Observed variability among commercial ELISA platforms may compromise comparability between studies. Harmonisation, standardised reference materials, and cross-validation are necessary before renalase assays can be used reliably in clinical practice.

Humans

Quality assessment, prognostic factors, and biomarkers for brain tumor analysis: a comprehensive systematic review.

The brain tumors possess different causative factors and properties, making their diagnosis and treatment difficult. Growth of these cancers usually leads to compression of the adjacent nerves and obstruction of the flow of cerebrospinal fluid, thus leading to increase in intracranial pressure. This affects the working of brain in many ways; thus, the difficulty involved in its treatment. With the improvements in technology in neuroimaging, including Diffusion Tensor Imaging (DTI), Positron Emission Tomography (PET), and multiparametric Magnetic Resonance Imaging (mpMRI), the diagnosis process has become easy. The effectiveness of any form of therapy in such patients depends primarily on their prognosis. While it is a common practice that physicians determine the prognosis of the disease by considering the age of the patient, histological grade of the tumor, and resection status, now this method has become more comprehensive by adding molecular signature and genetic analyses to the list of criteria. Next-generation sequencing (NGS) allows a reliable molecular classification. It increases the level of risk stratification, facilitating the application of therapies tailored to individual patients. Thus, molecular oncology has greatly changed our views on brain tumors' pathology and prognosis while neoadjuvant treatments aim at increasing the survival rate. On the other hand, radiogenomics is a field of study that combines non-invasive imaging phenotypes and genomic information in order to find unique molecular signatures of tumors without collecting samples from tumors. Molecular biomarkers are absolutely essential in the diagnosis of cancer, treatment monitoring, and recurrence of cancer. Advances in liquid biopsy technology, particularly the methods for circulating tumor DNA (ctDNA) and Extracellular Vesicle (EV) based analysis, have enabled the possibility of non-invasive monitoring of the progression of the tumors over time. This review highlights key studies and important scientific works about imaging technologies, biomarkers, and prognostic factors of malignant brain tumors.

Humans

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000&#xa0;nM. However, due to carry-over observed at 10,000&#xa0;nM, the validated calibration range was established at 1-2000&#xa0;nM, with matrix-dependent LLOQs of 1-10&#xa0;nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals

Emergence of a Novel, Phenotypically Difficult-to-Detect Vancomycin-Resistant Enterococcus faecium Clone (ST117/CT7799).

A significant increase of vancomycin-resistant Enterococcus faecium (VREfm) infections was observed in South-Eastern Austria since 2024. The prolonged outbreak is caused by a novel vanB-VREfm clone (ST117/CT7799, "VREfmstyr"). This study characterizes the atypical difficult-to-detect resistance phenotype and assesses the genomic relatedness of the isolates. Patient and outbreak characteristics were investigated including whole genome sequencing of the isolates. Sensitivity of broth microdilution (BMD), gradient tests (GT), disk diffusion (DD), and automated susceptibility testing (VITEK2) was compared. The performance of commercial screening media was evaluated. From sporadic detections in early 2024 case numbers began to rise during the year. In 30/31 (97%) of all cases, intra-hospital transmission was considered likely and an association with invasive procedures was identified in most cases. Core genome multilocus sequence typing revealed only six allelic differences between VREfmstyr isolates collected in a 12-month period, all belonging to the E. faecium ST117/CT7799 lineage. BMD detected vancomycin resistance (MIC&#x2009;>&#x2009;4&#x2009;mg/L) in no more than 16/31 (52%) of isolates after 24&#x2009;h incubation, while GT and DD misclassified all isolates. Only prolonged incubation improved the performance of these assays. VITEK2 analysis, however, correctly classified all 31 isolates. Of four commercially available VRE-screening agars, only one was capable of detecting VREfmstyr after 24&#x2009;h incubation. The emergence and clonal dissemination of VREfm ST117/CT7799 reveals a serious diagnostic gap as commonly used diagnostic algorithms fail to reliably detect this resistance phenotype. Our findings should help to further evaluate the true geographical distribution and clinical significance of this novel VREfm clone.

Enterococcus faecium

Indications, Techniques and Complications Associated With Pterygoid Implants: A Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Pterygoid implants represent a graftless option for rehabilitation of patients with posterior maxillary atrophy, engaging the dense cortical bone of the pterygomaxillary complex. Despite clinical growth, a comprehensive synthesis of indications, surgical techniques, and complications is lacking. This review evaluated the prevalence of complications, implant survival rates, and marginal bone loss (MBL) associated with pterygoid implant placement. METHODS: The reporting of this review follows PRISMA 2020 guidelines. Six electronic databases (PubMed, Ovid, Scopus, WoS, CENTRAL, and Dentistry & Oral Sciences Source) were searched from 1 January 2020 to 31 December 2025. Included criteria comprised randomized and non-randomized clinical studies reporting outcomes of pterygoid implants (&#x2265;&#x2009;13&#x2009;mm) in adult patients with posterior maxillary atrophy (minimum 10 implants). Risk of bias was assessed using JBI critical appraisal checklists. Proportions were pooled using the Freeman-Tukey double arcsine transformation under a random-effects model. Certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies reporting 846 patients and 1915 pterygoid implants were included. The pooled survival rate was 97.9% (95% CI: 97.1%-98.6%; I2&#x2009;=&#x2009;0%; 14 studies) and the overall failure rate was 2.1% (95% CI: 1.4%-3.0%). Early failure rate was 0.9% (95% CI: 0.0%-3.0%; I2&#x2009;=&#x2009;59.5%). Late failure and MBL were summarized narratively. Certainty of evidence was low to very low. CONCLUSIONS: Pterygoid implants demonstrate excellent survival (97.9%) and low failure rates (2.1%), primarily early, supporting their reliability as a graftless solution for posterior maxillary atrophy. Complications appear infrequent though heterogeneously reported. Low evidence certainty necessitates prospective studies with standardized outcome reporting.

Humans

Unravelling bioanalytical innovations, degradation processes, and impurity landscapes of VEGFR inhibitors.

From pre-formulation studies to clinical trials, VEGFR-targeted small-molecule tyrosine kinase inhibitors (TKIs) require rigorous analytical standards. Bioanalysis, stability-indicating studies, and impurity profiling are used to examine chromatographic advances for VEGFR-targeted TKIs like sunitinib, pazopanib, axitinib, sorafenib, cabozantinib, vandetanib, apatinib, lenvatinib, nintedanib, and regorafenib. An LC-MS/MS and UPLC-MS/MS routinely show sub ng/mL performance, as shown by LLOQs (0.2&#xa0;ng/mL) for sunitinib and axitinib, 1&#xa0;ng/mL for pazopanib, 5-7&#xa0;ng/mL for sorafenib, 0.5-1.5&#xa0;ng/mL for regorafenib metabolic products, and 0.1-0.5&#xa0;ng/mL for lenvatinib. These approaches are used for pharmacokinetics and therapeutic drug monitoring due to their good correlation coefficient of 0.1-10,000&#xa0;ng/mL, accuracy of 95%-108%, and precision of 15% RSD. UPLC-QTOF-MS/MS distinguishes degradants and metabolites during forced degradation studies, enabling structural elucidation following ICH M7 risk evaluation protocol. HPTLC/MLC offers fast, sensitive screenings, while RP-HPLC/DAD or HPLC-UV offer reliable, cost-effective routine quality-control solutions with LOD/LOQ in the &#x3bc;g/mL range and linearity of 10-240&#xa0;&#x3bc;g/mL. This review lists the structures and CAS numbers of ten VEGFR-2 TKI degradants and metabolites, as well as pharmacopeial impurities in SMILES forms. It will be useful for future method development and regulatory applications. To ensure VEGFR-targeted TKI quality, safety, and therapeutic efficacy, LC-MS/MS for trace quantification and HRMS for structure elucidation provide a robust, future-oriented framework. To improve VEGFR-targeted TKI quality, safety, and regulatory compliance, analytical development should focus on HRMS-based impurity characterization, AI-assisted degradation prediction, green chromatography, and harmonized bioanalytical validation.

Humans

Treatment of Established Groin Lymphatic Complications After Arterial Surgery: A Systematic Review.

BACKGROUND: To systematically review the effectiveness and safety of interventions for established groin lymphatic complications after arterial vascular surgery. METHODS: PubMed, Embase, and Cochrane CENTRAL were searched from inception to May 28, 2025. This review was registered in PROSPERO (CRD420251061708) and conducted according to PRISMA, PRISMA-S, and Synthesis Without Meta-analysis (SWiM) guidance. Eligible studies included adults with established groin lymphorrhea/lymphocutaneous fistula or seroma/lymphocele after arterial exposure in the common femoral or iliofemoral region. Prophylactic studies were excluded. Two reviewers independently screened studies and assessed full texts. Prespecified outcomes were resolution, time to resolution, length of stay, surgical site infection, wound complications, reintervention, and recurrence. Owing to substantial heterogeneity, meta-analysis was not performed. RESULTS: Eighteen retrospective single-center studies were included; no randomized trials were identified. Reported strategy-family totals were operative control (n = 240, including 55 dye-assisted cases), intranodal lymphangiography with glue embolization (n = 39), intracavitary or chemical instillation (n = 52), negative-pressure wound therapy (n = 20), radiotherapy (n = 206), and drainage or aspiration alone (n = 7). One additional cohort compared nonsurgical with surgical management. Definitions, follow-up windows, and statistical reporting were inconsistent, and arm-level denominators were frequently incomplete. Risk of bias was serious to critical across the evidence base, mainly because of retrospective design, confounding by indication, treatment-selection bias, inconsistent outcome definitions, and incomplete reporting. Using GRADE principles, certainty of evidence was very low across strategies and phenotypes. Across study arms, conduit-directed approaches for external leak and cavity-directed approaches for encapsulated collections often achieved control, but valid comparative inference was not possible. CONCLUSION: Evidence is limited to small retrospective series with heterogeneous definitions, serious to critical risk of bias, and very low certainty. Reliable comparisons between interventions cannot currently be made. Standardized phenotype-specific definitions and outcome reporting are needed to support prospective studies and future trials.

Humans

Micro- and nanoplastics-induced neurotoxicity: a CNS-centered, evidence-graded adverse outcome pathway framework based on systematic weight-of-evidence assessment.

Micro- and nanoplastics (MPs/NPs) are ubiquitous anthropogenic particulate pollutants posing emerging threats to human neurological health. Severe heterogeneity in particle physicochemical properties, environmental aging status, exposure paradigms and experimental platforms has created persistent mechanistic uncertainties in MP/NP neurotoxicology, hindering reliable hazard characterization and risk translation. Here, we systematically consolidate empirical toxicological evidence and construct a dedicated central nervous system (CNS)-targeted adverse outcome pathway (AOP) network integrated with rigorous weight-of-evidence (WoE) grading to elucidate the hierarchical, particle-specific toxic cascades underlying MP/NP-induced neural injury. Our synthesis overturns the conventional linear toxicity paradigm, demonstrating that MPs/NPs trigger neurotoxicity via a complex multi-input mechanistic network. We definitively establish oxidative stress as a robust early convergent key event-rather than a universal molecular initiating event-orchestrating ROS overproduction, lipid peroxidation, mitochondrial dysfunction, and neuroinflammation to propagate neuronal damage. This core module is driven by five distinct particulate upstream triggers: particle-biomolecule interfacial perturbation, corona-facilitated cellular internalization, plastic-associated chemical leaching, aging-derived free radical reactivity, and gut-borne systemic neurotoxic signaling. Downstream pathogenic outcomes encompass glial overactivation, neurotransmitter dyshomeostasis, autophagy-lysosome dysfunction, metabolic reprogramming, regulated neuronal cell death, and behavioral impairments. Tiered WoE analysis confirms strong validation for early oxidative/inflammatory cascades, moderate support for gut-brain axis crosstalk and intracellular trafficking disruption, and nascent evidence for synaptic dysfunction and neurodegeneration-linked proteostatic defects. Extrapolation to human health risk remains constrained by the frequent use of high-dose exposure paradigms, limited validated data on internal dosimetry in the human brain, discrepancies between effective concentrations in experimental models and environmentally relevant human tissue burdens, and insufficient causal validation of distal adverse outcomes. We highlight key research priorities including aged mixed-particle exposure systems, leachate-controlled assays, quantitative internal dose evaluation, and mechanistic intervention verification. This evidence-stratified AOP framework resolves longstanding mechanistic ambiguities in particulate neurotoxicity, providing a standardized, causality-based foundation for future mechanistic exploration and health risk assessment of global plastic pollution.

Adverse outcome pathway

Clinical accuracy and short-term outcomes of intraoral photogrammetry for complete-arch implant rehabilitation: A retrospective multicentre study on 35 patients.

OBJECTIVES: To evaluate the clinical accuracy and short-term outcomes of complete-arch implant-supported fixed dental prostheses (ISFDPs) fabricated using an intraoral photogrammetry (IPG) based digital workflow in completely edentulous patients. METHODS: This multicenter retrospective clinical study included 35 patients rehabilitated with 52 complete-arch ISFDPs (10 FP1, 18 FP2 and 24 FP3 restorations) supported by 221 implants. All definitive prostheses were designed and fabricated using a fully digital workflow initiated by IPG acquisition with the Aoralscan Elite IPG&#xae; (SHINING 3D). The primary outcome was clinical accuracy, assessed at definitive prosthesis delivery through evaluation of passive fit using the Sheffield test and radiographic verification. Secondary outcomes included biologic and prosthetic complications, as well as implant and prosthesis survival rates during the follow-up. RESULTS: Passive fit was achieved in all definitive restorations (100%). Radiographic evaluation confirmed accurate marginal adaptation at the implant-prosthesis interface in all cases. No statistically significant differences in clinical accuracy were observed according to treated arch, number of supporting implants, or prosthetic design (P > .05). During a mean follow-up period of 12.1 &#xb1; 3.5 months, biologic and prosthetic complications were limited and generally minor. Implant survival was 99.5%, and prosthesis survival was 100%. CONCLUSIONS: Within the limitations of this retrospective clinical study, the IPG based workflow demonstrated high clinical accuracy and predictable short-term outcomes for complete-arch implant rehabilitation, consistently enabling passive fit and favorable prosthetic performance. CLINICAL RELEVANCE: IPG may represent a clinically reliable and predictable approach for complete-arch digital implant impression acquisition. The high rates of passive fit, together with the low incidence of biologic and prosthetic complications observed in this multicenter clinical study, support the use of IPG based workflows for the fabrication of complete-arch ISFDPs.

Humans