Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MAGNETICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Investigation of magnetic fluids by ultrasonic and magnetic methods

The influence of magnetic field on the acoustic and magnetic properties of magnetic liquids is discussed. By fitting the curve of Taketomi's theory to the experimental data of the anisotropy of ultrasonic attenuation, the values of quantities describing the structure of magnetic liquids have been determined. Moreover, the dependence of magnetic susceptibility on frequency has been measured. It shows that two processes of magnetization, based on the mechanisms proposed by Brown and Neel, contribute to the magnetization of the magnetic liquid.

Journal Article↗

Magnetophoretic velocimetry of manganese(II) in a single microdroplet in a flow system under a high gradient magnetic field generated with a superconducting magnet.

An experimental system for magnetophoretic velocimetry, which could determine the volume magnetic susceptibility of a single particle dispersed in a liquid phase from a magnetophoretic velocity, has been developed. A micrometer-sized high-gradient magnetic field could be generated in a capillary by a pair of iron pole pieces in a superconducting magnet (10 T). The magnetophoretic behavior of a single particle in a capillary flow system was investigated under the inhomogeneous magnetic field. From the magnetophoretic velocity of a polystyrene latex particle dispersed in a MnCl2 aqueous solution, the product of the magnetic flux density and the gradient, B(dB/dx), was determined as a function of the position along the capillary. The maximum value of B(dB/dx) was 4.7 x 10(4) T2 m(-1), which was approximately 100 times higher than that obtained by two Nd-Fe-B permanent magnets (0.4 T). Organic droplets extracting manganese(II) with 2-thenoyltrifluoroacetone and tri-n-octylphosphine oxide from MnCl2 solution were used as test samples. The difference of the volume magnetic susceptibility between the droplet and the medium could be determined from the magnetophoretic velocity. This method allowed us to continuously measure a volume magnetic susceptibility of 10-6 level for a picoliter droplet and to determine manganese(II) in the single droplet at the attomole level.

Journal Article↗

Single-molecule magnets: a new class of tetranuclear manganese magnets.

The preparation, X-ray structure, and detailed physical characterization are presented for a new type of single-molecule magnet [Mn4(O2CMe)2(pdmH)6](ClO4)2 (1). Complex 1.2MeCN.Et2O crystallizes in the triclinic space group P1, with cell dimensions at 130 K of a = 11.914(3) A, b = 15.347(4) A, c = 9.660(3) A, alpha = 104.58(1) degree, beta = 93.42(1) degree, gamma = 106.06(1) degree, and Z = 1. The cation lies on an inversion center and consists of a planar Mn4 rhombus that is mixed-valent, MnIII2MnII2. The pdmH- ligands (pdmH2 is pyridine-2,6-dimethanol) function as either bidentate or tridentate ligands. The bridging between Mn atoms is established by either a deprotonated oxygen atom of a pdmH- ligand or an acetate ligand. The solvated complex readily loses all acetonitrile and ether solvate molecules to give complex 1, which with time becomes hydrated to give 1.2.5H2O. Direct current and alternating current magnetic susceptibility data are given for 1 and 1.2.5H2O and indicate that the desolvated complex has a S = 8 ground state, whereas the hydrated 1.2.5H2O has a S = 9 ground state. Ferromagnetic interactions between MnIII-MnII and MnIII-MnIII pairs result in parallel spin alignments of the S = 5/2 MnII and S = 2 MnIII ions. High-frequency EPR spectra were run for complex 1.2.5H2O at frequencies of 218, 328, and 436 GHz in the 4.5-30 K range. A magnetic-field-oriented polycrystallite sample was employed. Fine structure is clearly seen in this parallel-field EPR spectrum. The transition fields were least-squares-fit to give g = 1.99, D = -0.451 K, and B4 degrees = 2.94 x 10(-5) K for the S = 9 ground state of 1.2.5H2O. A molecule with a large-spin ground state with D < 0 can function as a single-molecule magnet, as detected by techniques such as ac magnetic susceptibility. Out-of-phase ac signals (chi'' M) were seen for complexes 1 and 1.2.5H2O to show that these complexes are single-molecule magnets. A sample of 1 was studied by ac susceptibility in the 0.4-6.4 K range with the ac field oscillating at frequencies in the 1.1-1000 Hz range. A single peak in chi'' M vs temperature plots was seen for each frequency; the temperature of the chi'' M peak varies from 2.03 K at 995 Hz to 1.16 K at 1.1 Hz. Magnetization relaxation rates were evaluated in this way. An Arrhenius plot gave an activation energy of 17.3 K, which, as expected, is less than the 22.4 K value calculated for the thermodynamic barrier for magnetization direction reversal for an S = 8 complex with D = -0.35 K. The 1.2.5H2O complex with an S = 9 ground state has its chi'' M peaks at higher temperatures.

Journal Article↗

Characterization of a soluble molecular magnet: unusual magnetic behavior of cyano-bridged Gd(III)-Cr(III) complexes with one-dimensional and nanoscaled square structures.

Two cyano-bridged Gd(III)-Cr(III) complexes [Gd(urea)(4)(H(2)O)(2)](2)[Cr(CN)(6)](2) (1) and ([Gd(capro)(2)(H(2)O)(4)Cr(CN)(6)].H(2)O)(n)(2) (capro represents caprolactam) have been synthesized and characterized structurally and magnetically. Complex 1 has a tetranuclear Gd(2)Cr(2) square structure, in which two cis-CN(-) ligands of each [Cr(CN)(6)] link two [Gd(urea)(4)(H(2)O)(2)] groups and in turn, two [Gd(urea)(4)(H(2)O)(2)] link two [Cr(CN)(6)] in a cis fashion. Complex 2 is composed of 1D chains with alternating [Gd(capro)(2)(H(2)O)(4)] and [Cr(CN)(6)] moieties connected by the trans-CN(-) ligands of [Cr(CN)(6)]. The dehydration of 2 at 120 degrees C generates a new complex, [Gd(capro)(2)(H(2)O)(2)Cr(CN)(6)] (2'). Magnetic studies show the existence of antiferromagnetic Gd(III)-Cr(III) interaction in these complexes. On the basis of the tetranuclear model, the magnetic susceptibilities of 1 have been analyzed giving the intermetallic magnetic coupling constant of -0.36 cm(-1). Complex 2' exhibits a ferrimagnetic order below 2.1 K. Interestingly, 2' is quite soluble in water, and slow evaporation of the solution gives the hydrated complex 2. Therefore, 2' is a soluble molecular magnet, and this significant behavior implies potential applications. Isothermal magnetization measurements of 2' and other cyano-bridged Gd(III)-Cr(III) molecular magnets show unusual field-induced metamagnetic behavior from the ferrimagnetic ground state to the ferromagnetic state. Field dependence of magnetization of the cyano-bridged Gd(III)-Cr(III) complexes shows unusual field-induced metamagnetic behavior from the ferrimagnetic ground state to the ferromagnetic state.

Journal Article↗

Synthesis, structure, and magnetic properties of a Mn(21) single-molecule magnet.

The reaction of [Mn(3)O(O(2)CMe)(6)(py)(3)](ClO(4)) (1; 3Mn(III)) with [Mn(10)O(4)(OH)(2)(O(2)CMe)(8)(hmp)(8)](ClO(4))(4) (2; 10Mn(III)) in MeCN affords the new mixed-valent complex [Mn(21)O(14)(OH)(2)(O(2)CMe)(16)(hmp)(8)(pic)(2)(py)(H(2)O)](ClO(4))(4) (3; 3Mn(II)-18Mn(III); hmp(-) is the anion of 2-(hydroxymethyl)pyridine), with an average Mn oxidation state of +2.85. Complex 3.7MeCN crystallizes in the triclinic space group P. The structure consists of a low symmetry [Mn(21)(micro(4)-O)(4)(micro(3)-O)(12)(micro-O)(16)] core, with peripheral ligation provided by 16 MeCO(2)(-), 8 hmp(-), and 2 pic(-) groups and one molecule each of water and pyridine. The magnetic properties of 3 were investigated by both dc and ac magnetic susceptibility measurements. Fitting of dc magnetization data collected in the 0.1-0.8 T and 1.8-4.0 K ranges gave S = (17)/(2), D approximately -0.086 cm(-)(1), and g approximately 1.8, where S is the molecular spin of the Mn(21) complex and D is the axial zero-field splitting parameter. ac susceptibility studies in the 10-997 Hz frequency range reveal the presence of a frequency-dependent out-of-phase ac magnetic susceptibility (chi(M)' ') signal consistent with slow magnetization relaxation rates. Fitting of dc magnetization decay versus time data to the Arrhenius equation gave a value of the effective barrier to relaxation (U(eff)) of 13.2 K. Magnetization versus applied dc field sweeps exhibited hysteresis. Thus, complex 3 is a new member of the small but growing family of single-molecule magnets.

Journal Article↗

Microstructured magnetic materials for RF flux guides in magnetic resonance imaging.

Magnetic resonance imaging and spectroscopy systems use coils, either singly or as arrays, to intercept radio-frequency (RF) magnetic flux from regions of interest, often deep within the body. Here, we show that a new magnetic material offers novel possibilities for guiding RF flux to the receiver coil, permitting a clear image to be obtained where none might otherwise be detectable. The new material contains microstructure designed according to concepts taken from the field of photonic band gap materials. In the RF range, it has a magnetic permeability that can be produced to specification while exhibiting negligible direct-current magnetism. The latter property is vital to avoid perturbing the static and audio-frequency magnetic fields needed to obtain image and spectral data. The concept offers a new paradigm for the manipulation of RF flux in all nuclear magnetic resonance systems.

Humans↗

Quantitative analysis of magnetic resonance imaging susceptibility artifacts caused by neurosurgical biomaterials: comparison of 0.5, 1.5, and 3.0 Tesla magnetic fields.

Magnetic resonance (MR) imaging is an important diagnostic tool for neurosurgical diseases but susceptibility artifacts caused by biomaterial instrumentation frequently causes difficulty in visualizing postoperative changes. The susceptibility artifacts caused by neurosurgical biomaterials were compared quantitatively by 0.5, 1.5, and 3.0 Tesla MR imaging. MR imaging of uniform size and shape of pieces ceramic (zirconia), pure titanium, titanium alloy, and cobalt-based alloy was performed at 0.5, 1.5, and 3.0 Tesla. A linear region of interest was defined across the center of the biomaterial in the transverse direction, and the susceptibility artifact diameter was calculated. Susceptibility artifacts developed around all biomaterials at all magnetic field strengths. The artifact diameters caused by pure titanium, titanium alloy, and cobalt-based alloy increased in the order of 0.5, 1.5, to 3.0 Tesla magnetic fields. The artifact diameter of ceramic was not influenced by magnetic field strength, and was the smallest of all biomaterials at all magnetic field strengths. The artifacts caused by biomaterials except ceramic increase with the magnetic field strength. Ceramic instrumentation will minimize artifacts in all magnetic fields.

Artifacts↗

Aneurysm clips: magnetic quantification and magnetic resonance imaging safety. Technical note.

Knowledge of the magnetic properties of cerebral aneurysm clips in patients undergoing magnetic resonance (MR) imaging is imperative. The authors quantified in electromagnetic units the magnetic properties of 13 different types of aneurysm clips by using a vibrating sample magnetometer. Their results showed that the magnetic moment of these clips ranged from 0.15 EMU/g to as high as 152.7 EMU/g. Based on these results and tests of the movement of the clips during MR imaging, they conclude that aneurysm clips with a magnetic moment less than 1 EMU/g may be safely used during MR imaging. The quantification of magnetic properties into electromagnetic units by using a vibrating sample magnetometer is a reliable method applicable to any testing field gradient. This method can be used as a standard to measure and label the magnetic properties of aneurysm clips.

Aneurysm↗

[Magnet systems for magnetic resonance tomography].

In the past fifteen years, Magnetic Resonance Tomography (MRT) has become a valuable tool for medical diagnostics. At the same time, Magnetic Resonance Spectroscopy (MRS) has attracted more and more attention in medical and other related areas of investigations. For both methods it is necessary to provide a magnetic field, which can be generated by resistive magnets, by permanent magnets as well as by superconducting magnets. These three concepts are described and compared together with the advantages of each design and the considerations that must be addressed regarding the planned use and the availability of a suitable site. In addition to the main magnet important additions like gradient and shim coils, aspects of site planning and future problems are discussed.

Equipment Design↗

Cell-cycle kinetics of Friend erythroleukemia cells in a magnetically shielded room and in a low-frequency/low-intensity magnetic field.

This work was undertaken to compare the behavior of Friend erythroleukemia cells in a solenoid, where the magnetic field was 70 microT at 50 Hz (plus 45 microT DC of Earth) with that of the same cells in a magnetically shielded room, where the magnetic field was attenuated to 20 nT DC and 2.5 pT AC. The control laboratory magnetic field corresponded to 45 microT DC and a stray 50 Hz field below 0.2 microT. The culture growth cycle of cells maintained inside the solenoid was slightly accelerated compared with that of cells maintained outside the solenoid (P < .05). This stimulation probably depended on sensitivity of cell cycle to a magnetic field, because, inside the solenoid, the percentage of G1 cells slightly increased during the culture growth cycle, whereas that of S cells slightly decreased. Acceleration of growth was detected soon after exposure of the cultures to the solenoid field, and growth did not change further if the action of this field continued for a long time, accounting for adaptation. The solenoid field also caused a small increase of cell survival without influencing cell volume. By contrast, the culture growth cycle of cells maintained inside the magnetically shielded room was slightly decelerated compared with that of cells maintained outside the room (P < .05). The essential absence of any field inside the magnetically shielded room also caused a small increase of cell volume, whereas, during the culture growth cycle, the percentage of G1 cells decreased, and that of S cells increased. The majority of these events did not change in cells induced to differentiate hemoglobin through dimethylsulfoxide.

Animals↗

Temporally incoherent magnetic fields mitigate the response of biological systems to temporally coherent magnetic fields.

We have previously demonstrated that a weak, extremely-low-frequency magnetic field must be coherent for some minimum length of time (approximately 10 s) in order to affect the specific activity of ornithine decarboxylase (ODC) in L929 mouse cells. In this study we explore whether or not the superposition of an incoherent (noise) magnetic field can block the bioeffect of a coherent 60 Hz magnetic field, since the sum of the two fields is incoherent. An experimental test of this idea was conducted using as a biological marker the twofold enhancement of ODC activity found in L929 murine cells after exposure to a 60 Hz, 10 microT rms magnetic field. We superimposed an incoherent magnetic noise field, containing frequencies from 30 to 90 Hz, whose rms amplitude was comparable to that of the 60 Hz field. Under these conditions the ODC activity observed after exposure was equal to control levels. It is concluded that the superposition of incoherent magnetic fields can block the enhancement of ODC activity by a coherent magnetic field if the strength of the incoherent field is equal to or greater than that of the coherent field. When the superimposed, incoherent noise field was reduced in strength, the enhancement of ODC activity by the coherent field increased. Full ODC enhancement was obtained when the rms value of the applied EM noise was less than one-tenth that of the coherent field. These results are discussed in relation to the question of cellular detection of weak EM fields in the presence of endogenous thermal noise fields.

Animals↗

High-spin molecules with magnetic anisotropy toward single-molecule magnets.

High-spin molecules with easy-axis magnetic anisotropy show slow magnetic relaxation of spin-flipping along the axis of magnetic anisotropy and are called single-molecule magnets (SMMs). SMMs behave as molecular-size permanent magnets at low temperature and magnetic relaxation occurs by quantum tunneling processes; such molecules are promising candidates for use in quantum devices. We first discuss intramolecular ferromagnetic interactions for preparing high-spin molecules. Second, we determine the magnetic anisotropy for single metal ions with d(n) configurations and discuss how molecular anisotropy arises from single-ion anisotropy of the assembled component metal ions.

Magnetics↗

Lack of mutagenic and co-mutagenic effects of magnetic fields during magnetic resonance imaging.

Mutagenic and co-mutagenic effects of static, pulsed bipolar gradient, and high-frequency magnetic fields, as well as combinations of them, were examined using the Ames test. The Ames test using Salmonella typhimurium bacteria, wild-type strain RTA, preincubation assay, without metabolic activation, was performed. All combinations of magnetic fields were tested with and without co-exposure to N-methyl-N'-nitro-N-nitrosoguanidine and benzo[a]pyrene-4,5-oxide, ethylene oxide, carboplatin, or cisplatin. As expected, chemical mutagens caused a clear-cut increase of the revertants in the Ames test. However, neither the static fields nor a combination of a static magnetic field with the time-varying bipolar gradient field or a pulsed high-frequency magnetic field caused an alteration in the number of revertants in the Ames test. No co-mutagenic effect of any magnetic field combination was observed. In conclusion, magnetic fields used during clinical magnetic resonance imaging (MRI) were neither mutagenic nor co-mutagenic.

Animals↗

A cylindrically symmetric magnetic shield for a large-bore 3.0 Tesla magnet.

A 3.0 Tesla, 0.80-m bore magnet replaced our previous 1.9 Tesla, 0.76-m magnet. The 3.0 Tesla replacement magnet had a dipole moment of 1.7 with respect to that of the 1.9 Tesla magnet. The pre-existing cylindrically symmetric passive steel shielding was modified to confine the fringe fields of the replacement magnet to match those of the previous magnet. A cylindrically symmetric inner shield insert of about 20,000 kg was designed, fabricated, and installed. Upon energization of the magnet, the combined shielding met all design criteria. Alternative designs, optimization of cylindrically symmetric designs, and costs of fabrication, are presented herein.

Carbon↗

Effective targeting of magnetic radioactive 90Y-microspheres to tumor cells by an externally applied magnetic field. Preliminary in vitro and in vivo results.

Magnetic biodegradable poly(lactic acid) microspheres that incorporate both magnetite and the beta-emitter 90Y were prepared. By applying a directional external magnetic field gradient in excess of 0.02 Tesla/cm across a 96-well plate containing neuroblastoma cells incubated with the 90Y magnetite loaded microspheres, the radiation dose to the cells could be enhanced or reduced relative to the dose from a uniform loading of the well with 90Y-DTPA. Using the MTT assay, cell survival was measured for the magnetic field directed from above (cell sparing) and from below (cell targeting) the well plate, resulting in 65 +/- 8% or 18 +/- 5% survival respectively. This method was then applied to an in vivo murine tumor model. The biodistribution of intraperitoneally injected magnetic radioactive microspheres, after 24 h in mice, showed that 73 +/- 32% of the radioactivity was found on the subcutaneous tumor that had a rare earth magnet fixed above it. In contrast, the tumor radioactivity with no attached magnet was 6 +/- 4%. Magnetically targeted radiopolymers such as 90Y-microspheres show great promise for regional or intracavitary radiotherapy.

Animals↗

Crystal structures and magnetic properties of complexes of M(II)Cl2 (M = Cu, Ni, and Co) coordinated with 4-(N-tert-butyloxyamino)-2-(methoxymethylenyl)pyridine: 2D magnetic anisotropy of the aminoxyl-Co(II) complex in the crystalline state.

Three metal complexes, [M(II)Cl2(4NOPy-OMe)2] (M = Cu (1), Ni (2), and Co (3)), were prepared by mixing the corresponding metal chloride and 4-(N-tert-butyloxyamino)-2-(methoxymethylenyl)pyridine, 4NOPy-OMe, in 1:2 ratio. Complex 1 has two structures (complexes A and B) with similar coordination geometries, compressed octahedrons. In the crystal structure, complexes A and B locate alternately in short distances (C(radical)...C(beta) = 3.17 and 3.23 A) to form a 1-D chain structure. Complexes 2 and 3 are isomorphous and have a slightly distorted octahedral structure. In the crystal structure, both complexes have intermolecular short contacts (C(radical)...C(alpha) = 3.46 and 3.52 A for 2 and 3, respectively) to form the 2-D structures. The temperature dependence of the chi(mol)T values for the three complexes indicated that the magnetic interactions between the radicals and the metal ions within the complexes were ferromagnetic. By fitting a modified Fisher 1-D model to the data of the chi(mol)T vs T plot for 1, we estimated the intra- and intermolecular (intrachain) exchange coupling constants to be J1/kB = 60.2 and J2/kB = -7.02 K, respectively. On the other hand, complexes 2 and 3 showed steep increases of the chi(mol)T value below ca. 3 K, indicating that the long-range magnetic ordering is operating. The 1/chi(mol) vs T plot for 2 was analyzed by a Curie-Weiss model to give theta = 6.25 K and C = 2.02 cm3 K mol(-1) with g(Ni) = 2.25. Complex 3 was investigated in more detail using an orientated sample. Magnetic behavior strongly depends on the direction of the applied field, in which the c axis perpendicular to the ab plane is an easy axis for magnetization. Direct current (dc) and alternating current (ac) magnetic susceptibility measurements revealed that complex 3 had a magnetic phase transition of T(c) = 2.14 K and exhibited a glasslike magnetic behavior below T(c).

Cobalt↗

Magnetization curves of haemoproteins measured by low-temperature magnetic-circular-dichroism spectroscopy.

The magnetic-circular-dichroism (m.c.d.) spectra of methymyoglobin cyanide and oxidized horse heart cytochrome c were measured in the region of the Soret band over a range of temperatures from 1.5 to 50 K and in fields from 0 to 5T. A similar study has been made with reduced bovine heart cytochrome c oxidase, which contains one high-spin ferrous haem, namely a3. M.c.d. magnetization curves characteristic of an isolated Kramer's ground state with spin S = 1/2. These curves contrast with the magnetization curve of the high-spin ferrous haem with spin S = 2. The electronic ground state of the latter compound contains zero-field components that are thermally accessible over the temperature range of the experiment. Hence the magnetization curves are a complex nested set. The magnetization curves of the S = 1/2 proteins were analysed and it is shown that it is possible to make estimates of the ground-state g-factors even in the presence of rhombic anisotropy, provided that some knowledge of the polarizations of the electronic transitions is available. The striking difference between the m.c.d. magnetization curves of a simple S = 1/2 paramagnet and magnetically complex ground state should prove extremely useful when m.c.d. spectroscopy is sued to probe the magentic properties of metal centres in proteins, and should have wide application beyond the field of haemoproteins.

Circular Dichroism↗

Patient positioning using artificial intelligence neural networks, trained magnetic field sensors and magnetic implants.

The purpose of this study was to evaluate the precision of a sensor and to ascertain the maximum distance between the sensor and the magnet, in a magnetic positioning system for external beam radiotherapy using a trained artificial intelligence neural network for position determination. Magnetic positioning for radiotherapy, previously described by Lennernäs and Nilsson, is a functional technique, but it is time consuming. The sensors are large and the distance between the sensor and the magnetic implant is limited to short distances. This paper presents a new technique for positioning, using an artificial intelligence neural network, which was trained to position the magnetic implant with at least 0.5 mm resolution in X and Y dimensions. The possibility of using the system for determination in the Z dimension, that is the distance between the magnet and the sensor, was also investigated. After training, this system positioned the magnet with a mean error of maximum 0.15 mm in all dimensions and up to 13 mm from the sensor. Of 400 test positions, 8 determinations had an error larger than 0.5 mm, maximum 0.55 mm. A position was determined in approximately 0.01 s.

Humans↗