Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Liquid Phase Microextraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Liquid-phase microextraction of basic drugs--selection of extraction mode based on computer calculated solubility data.

The extractability of 58 different basic drugs by 3-phase liquid-phase microextraction (LPME) was studied. Extraction recoveries were correlated to solubility data and log D data calculated with a commercial computer program. The basic drugs were extracted from 1.5 mL water samples (pH 13) through approximately 15 microL of dodecyl acetate immobilized within the pores of a porous polypropylene hollow fibre (organic phase), and into 15 microL of 10 mM HCl (acceptor solution) present inside the lumen of the hollow fibre. Compounds with a calculated solubility below 1 mg/mL at pH 2 were poorly recovered and remained principally in the organic phase. For these drugs, 2-phase LPME may be used as an alternative technique, where the aqueous acceptor phase is replaced by an organic solvent. In the solubility range 1-5 mg/mL, most drugs were effectively extracted (recovery >30%), whereas drugs belonging to the solubility range 5-150 mg/mL were all extracted with recoveries above 30% by 3-phase LPME. The hydrophilic nature of most drugs with solubilities above 150 mg/mL prevented them from entering the organic phase, and only those with log D >1.8 were effectively recovered by 3-phase LPME. For drugs with log D < 1.8 (and solubility >150 mg/mL), carrier-mediated LPME was found to be the preferred technique, where an ion-pair reagent (octanoic acid) was added to the sample. In the case of carrier-mediated LPME, the volume of sample was decreased to 100 microL to facilitate rapid extractions. Based on the present work, the extractability of new compounds may easily be predicted to speed up method development. Extractions were also accomplished from plasma samples, where interactions between proteins and the drugs may reduce the extraction recovery. However, dilution of the plasma samples with water and adjustment of pH into the alkaline region effectively suppressed drug-protein interactions for most of the drugs studied.

Humans↗

Application of hollow fiber liquid phase microextraction for the determination of insecticides in water.

In the present work, a novel sample pre-treatment technique for the determination of trace concentrations of some insecticide compounds in aqueous samples has been developed and applied to the determination of the selected analytes in environmental water samples. The extraction procedure is based on coupling polypropylene hollow fiber liquid phase microextraction (HF-LPME) with gas chromatography by flame thermionic detection (GC-FTD). For the development of the method, seven organophosphorous insecticides (dichlorvos, mevinphos-cis, ethoprophos, chlorpyrifos methyl, phenthoate, methidathion and carbofenothion) and one carbamate (carbofuran) were considered as target analytes. Several factors that influence the efficiency of HF-LPME were investigated and optimized including agitation, organic solvent, sample volume, exposure time, salt additives and pH. The optimized methodology exhibited good linearity with correlation coefficient = 0.990. The analytical precision for the target analytes ranged from 4.3 to 11.1 for within-day variation and 4.6 to 12.0% for between-day variation. The detection limits for all analytes were found in the range from 0.001 to 0.072 microg/L, well below the limits established by the EC Drinking Water Directive (EEC 80/778). Relative recoveries obtained by the proposed method from drinking and river water samples ranged from 80 to 104% with coefficient of variations ranging from 4.5 to 10.7%. The present methodology is easy, rapid, sensitive and requires small sample volumes to screen environmental water samples for insecticide residues.

Chemical Fractionation↗

Hollow fiber-mediated liquid-phase microextraction of chemical warfare agents from water.

Unambiguous detection and identification of chemical warfare agents (CWAs) and related compounds are of paramount importance from verification point of view of Chemical Weapons Convention (CWC). It requires development of fast, reliable, simple and reproducible sample preparation of CWAs from water which is likely to be contaminated during deliberate or inadvertent spread of CWAs. This work describes development of hollow fiber liquid-phase microextraction (HF-LPME) method for efficient extraction of CWAs (such as sarin, sulfur mustard and their analogues) from water followed by gas chromatography-mass spectrometric analysis. Extraction parameters, such as organic solvent, agitation, extraction time, and salt concentration were optimized. Best recoveries of target analytes were achieved using 1 microL trichloroethylene as extracting solvent, 1000 rpm stirring rate, 15 min extraction time, and 30% NaCl. Excellent precision was observed with less than 7.6% RSD. The limit of detection by HF-LPME was achieved up to 0.1 microg/L at 30% salt concentration.

Chemical Warfare Agents↗

In situ derivatization hollow fiber mediated liquid phase microextraction of alkylphosphonic acids from water.

Alkylphosphonic acids (APAs), particularly the methyl-, ethyl-, isopropyl- and n-propyl-phosphonic acids are important markers of extremely toxic nerve agents. Hence, their detection and identification is of vital importance to verification of chemical weapons convention (CWC). Verification analysis of CWC requires development of fast, reliable, simple and reproducible sample preparation methods of water and soil samples. Present investigation is focused on the optimization of alkylation of APAs in water with subsequent extraction of alkylated acids by hollow fiber liquid phase microextraction (HF-LPME). This simple and sensitive sample preparation of APAs from water offered better recoveries in comparison to conventionally used extraction technique. Under optimized conditions, the APAs were detected at the concentration of 0.5-0.75 microg/mL with S/N ratio > or = 5, whereas the LODs for alkyl APAs (monobasic APAs) were achieved up to 0.1 microg/mL. The developed method was finally tested with water samples supplied in 19th official proficiency test conducted by the OPCW.

Chromatography, Liquid↗

Solid-phase microextraction liquid chromatography/tandem mass spectrometry to determine postharvest fungicides in fruits.

A method to determine five postharvest fungicides (dichloran, flutriafol, o-phenylphenol, prochloraz, tolclofos methyl) in fruits (cherries, lemons, oranges, peaches) has been developed using solid-phase microextraction (SPME) coupled to liquid chromatography (LC) with photodiode array (DAD), mass spectrometry (MS), or tandem mass spectrometry (MS/MS) with ion trap detection. Extraction involved sample homogenization with an acetone/water solution (5:1), filtration, and acetone evaporation prior to fiber extraction. The pesticides were isolated with a fused-silica fiber coated with 50-microm Carbowax/template resin. The effects of pH, ion strength, sample volume, and extraction time were investigated, and their impact on the SPME-LC/MS was studied. Dynamic and static modes of desorption were compared and the variables affecting desorption processes in SPME-LC optimized. Static desorption provided the best recoveries and peak shapes. Recoveries at the limit of quantification (LOQ) levels were between 10% for prochloraz and 60% for o-phenylphenol, with relative standard deviations from 13.6% for prochloraz to 3.1% for o-phenylphenol. The versatility of the method was also exhibited by its excellent linearity in the concentration intervals between 0.0005 and 5 mg kg(-1) for dichloran and 0.01-10 mg kg(-1) for tolclofos methyl and prochloraz. LOQs ranged from 0.25 to 1 microg g(-1) using DAD, from 0.002 to 0.01 microg g(-1) using LC/MS, and from 0.0005 to 0.01 to microg g(-1) using LC/MS/MS. LOQs obtained in the present study using LC/MS and LC/MS/MS are lower than maximum residue limits established for all the fungicides in any matrix studied. The method enables to determine polar pesticides at low-microgram per gram levels in fruits.

Calibration↗

Development and application of microporous hollow fiber protected liquid-phase microextraction via gaseous diffusion to the determination of phenols in water.

A new organic solvent-free microextraction technique termed liquid-gas-liquid microextraction (LGLME) was developed. In this technique, a small amount (6 microl) of aqueous acceptor solution (0.5M NaOH) is introduced into the channel of a 2.65 cm polypropylene hollow fiber. The hollow fiber is then immersed in an aqueous sample donor solution. The aqueous acceptor phase in the channel of the hollow fiber is separated from the sample solution by the hydrophobic microporous hollow fiber wall with air inside its pores. The analytes (phenols) passed through the microporous hollow fiber membrane by gas diffusion and were then trapped by the basic acceptor solution. After extraction, the acceptor solution was withdrawn into a microsyringe and injected into a capillary electrophoresis sample vial for subsequent analysis. Limits of detection of between 0.5 and 10 microg/l for eight phenols could be achieved. The relative standard deviations (n=6) of this technique between 2.7 and 7.6%. The technique also provides good enrichment factors for all the eight analytes.

Chromatography, Gas↗

Liquid-phase microextraction of phenolic compounds combined with on-line preconcentration by field-amplified sample injection at low pH in micellar electrokinetic chromatography.

This paper describes a novel method that applies field-amplified sample injection (FASI) in micellar electrokinetic chromatography (MEKC) with a low pH background electrolyte (BGE). Six phenolic compounds prepared in water or NaOH solution were used as the test analytes. Sample was injected electrokinetically after the introduction of a plug of water. During the injection, the water plug was pumped out of the capillary inlet by the electroosmotic flow, and the phenolic anions migrated very quickly in the direction of the outlet. When the anions reached the boundary between the water plug and BGE, they were neutralized and ceased moving. Thereafter, MEKC was initiated for the separation. This on-line preconcentration method could be conveniently coupled with a liquid-liquid-liquid microextraction procedure, in which a hollow fiber was used as an extraction solvent support to extract the analytes from the water sample. The acceptor phase consisted of 8 mM NaOH. After extraction, the extract was analyzed directly by MEKC, as described.

Journal Article↗

Kinetic calibration for automated hollow fiber-protected liquid-phase microextraction.

Recently, a kinetic calibration method was developed for the quantification of microextraction. In this study, we proved that the sample volume and sampling time do not affect the feasibility of the calibration method, theoretically. The new theoretical considerations of the kinetic calibration method were validated through the investigation of the kinetics of the absorption and desorption processes of hollow fiber-protected liquid-phase microextractrion (HF-LPME). The kinetic calibration method for HF-LPME was successfully used to correct the matrix effects in the carbaryl analysis of a red wine sample. This research extends the kinetic calibration approach to fast sampling and some in-vial analyses, whereby the sample volume is not much larger than the product of the distribution coefficient and the volume of the extraction phase. HF-LPME technique was successfully automated with a CTC CombiPal autosampler, and a new device was designed for the automation of HF-LPME in this study. All steps of the HF-LPME technique, including the filling of the extraction solvent, sample transfer and agitation, withdrawing the solvent to a syringe, and introducing the extraction phase into the injector, were automated by a CTC autosampler. The fully automated HF-LPME technique is more convenient and more accurate. The good reproducibility of the fully automated HF-LPME technique eliminates the need for an internal standard to improve the analytical precision. The automated HF-LPME technique can be also used to obtain the distribution coefficient between the sample matrix and the extraction phase. The distribution coefficients of carbaryl and (13)C-carbaryl between 1-octanol and red wine, at 25 degrees C, were obtained with this technique.

Journal Article↗

Solid-phase microextraction liquid chromatography/tandem mass spectrometry for the analysis of chlorophenols in environmental samples.

Liquid chromatography with atmospheric pressure chemical ionisation mass spectrometry (LC/APCI-MS), using negative ion detection in a triple quadrupole instrument, was used for the determination of chlorophenols (CPs) in environmental samples. In-source collision-induced dissociation (CID) was compared with MS/MS fragmentation. In general, less fragmentation was observed in MS/MS as compared with in-source CID, with the latter providing more intense fragment ions due to chemical ionisation. Under MS/MS conditions [M - H - HCl](-) was the main fragment ion observed for all compounds except for pentachlorophenol, which showed no fragmentation. For multiple reaction monitoring (MRM) acquisition mode, the transition from [M - H](-) to [M - H - HCl](-) was selected, leading to detection limits down to 0.3 ng injected. Direct and headspace-solid-phase microextraction (HS-SPME) were used as preconcentration procedures for the analysis of CPs in wood and in industrially contaminated soils. CPs were quantified by standard addition, which led to good reproducibility (RSD between 4 and 11%) in both SIM and MRM modes, and detection limits down to ng/g. The combination of MS/MS and in-source CID allowed confirmation of the presence of CPs in environmental samples.

Chlorophenols↗

Analysis of benzene ethylamine derivatives in urine using the programmable dynamic liquid-phase microextraction (LPME) device.

An automated LPME device for a dynamic LPME method was manufactured and its extraction efficiency was tested using spiked urine samples. The developed home-made LPME device was a programmable automated syringe dispenser to overcome deteriorating precision and difficulties in manually manipulating the plunger repeatedly. To establish the optimum parameters for benzene ethylamines, the effects of sampling volume, solvent volume, pH, salt-effect, choice of solvents, plunger speed, and number of samplings were investigated. Good repeatabilities for the extraction of mephentermine, ephedrine, methoxyphenamine, selegiline, and bupropion were obtained and the RSD values were 2.4, 1.9, 1.3, 1.6 and 1.5% at a concentration of 3 microg mL(-1) in spiked urine samples, respectively. The limit of detection was below 0.05 microg mL(-1) for the investigated drugs. This developed device for LPME analysis gave good validation results and improved convenience.

Benzene Derivatives↗

Strategies for interfacing solid-phase microextraction with liquid chromatography.

Solid-phase microextraction (SPME) techniques are equally applicable to both volatile and non-volatile analytes, but the progress in applications to gas-phase separations has outpaced that of liquid-phase separations. The interfacing of SPME to gas chromatographic equipment has been straight-forward, requiring little modification of existing equipment. The requirement of solvent desorption for non-volatile or thermally labile analytes has, however, proven challenging for interfacing SPME with liquid-phase separations. Numerous options to achieve this have been described in the literature over the past decade, with applications in several different areas of analysis. To date, no single strategy or interface device design has proven optimal. During method development analysts must select the most appropriate interfacing technique among the options available. Out of these options three general strategies have emerged: (1) use of a manual injection interface tee; (2) in-tube SPME; and (3) off-line desorption followed by conventional liquid injection. In addition, there has been interest in coupling SPME directly to electrospray ionisation and matrix-assisted laser desorption ionisation (MALDI) for mass spectrometry. Several examples of each of these strategies are reviewed here, and an overview of their use and application is presented.

Chromatography, High Pressure Liquid↗

Identification and quantification of 77 pesticides in groundwater using solid phase coupled to liquid-liquid microextraction and reversed-phase liquid chromatography.

This paper describes a method for the extraction, separation, identification, and quantification of 77 pesticides (neutral, acidic, and basic) including some s-triazine metabolites. The method is appropriate for organically (e.g. with humic acids) highly loaded groundwater samples. A comparative study of a pH-controlled mixed solid phase (LiChroprep RP18/LiChrolut EN) extraction with different desorption solvents (acetonitrile or acetonitrile and dichloromethane/methanol) is elaborated. A subsequent liquid-liquid microextraction reduces matrix effects. The pesticides in the sample are separated using RP-HPLC, detected, and identified by diode array. The efficiency is illustrated on a natural groundwater sample from a phreatic aquifer.

Chromatography, High Pressure Liquid↗

Coupling solid-phase microextraction to liquid chromatography. A review.

Solid-phase microextraction (SPME) is a technique for extraction of organic compounds from gaseous, aqueous, and solid matrices. SPME is rapid and simple, ideal for automation and for in situ measurements, and no harmful solvents are needed. The principle of SPME involves equilibration of the analytes between the sample matrix and an organic polymeric phase coated on a fused-silica fiber. SPME is traditionally combined with analysis by gas chromatography (GC) and this combination has proved sensitive, accurate, and precise for quantitative analysis of different classes of volatile compound. More recently SPME has been coupled with liquid chromatography to widen its range of application to non-volatile and thermally unstable compounds also. This article reviews the status of SPME coupled with liquid chromatography. It focuses on different applications of the technique, e.g. environmental samples, biological fluids, and food samples, to show that SPME-HPLC has great potential in the analysis of a wide range of compounds in different matrices.

Journal Article↗

Determination of chlorophenols by solid-phase microextraction and liquid chromatography with electrochemical detection.

A solid-phase microextraction method has been developed for the determination of 19 chlorophenols (CPs) in environmental samples. The analytical procedure involves direct sampling of CPs from water using solid-phase microextraction (SPME) and determination by liquid chromatography with electrochemical detection (LC-ED). Three kinds of fibre [50 microm carbowax-templated resin (CW-TPR), 60 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) and 85 microm polyacrylate (PA)] were evaluated for the analysis of CPs. Of these fibres, CW-TPR is the most suitable for the determination of CPs in water. Optimal conditions for both desorption and absorption SPME processes, such as composition of the desorption solvent (water-acetonitrile-methanol, 20:30:50) and desorption time (5 min), extraction time (50 min) and temperature (40 degrees C) as well as pH (3.5) and ionic strength (6 g NaCl) were established. The precision of the SPME-LC-ED method gave relative standard deviations (RSDs) of between 4 and 11%. The method was linear over three to four orders of magnitude and the detection limits, from 3 to 8 ng l(-1), were lower than the European Community legislation limits for drinking water. The method was applied to the analysis of CPs in drinking water and wood samples.

Chlorophenols↗

Solid-phase microextraction-liquid chromatography (SPME-LC) determination of fluoxetine and norfluoxetine in plasma using a heated liquid flow through interface.

A simple and sensitive procedure using solid-phase microextraction coupled with high performance liquid chromatography (HPLC) to analyze fluoxetine (FLU) and its metabolite norfluoxetine (nor-FLU) in plasma samples was developed and validated. SPME conditions were optimized employing a factorial design. The sampling step was performed using a PDMS-DVB fiber and desorption was carried out in a novel homemade heated interface. Fluoxetine and norfluoxetine were analyzed by HPLC, using a C18 Phase Sep column (150mmx4.6mm, 3microm) packed "in house", and acetonitrile:acetate buffer 25mmoll(-1) with triethylamine 25mmoll(-1) pH 4.6 (70:30) as the mobile phase. The developed method has shown precision, linearity, specificity, and limit of quantification (LOQ) adequate to assay fluoxetine and norfluoxetine in plasma. Furthermore, the results obtained using the homemade interface has shown an improvement in the desorption process when compared with the results obtained using the off-line mode.

Chromatography, High Pressure Liquid↗

Combining drop-to-drop solvent microextraction with gas chromatography/mass spectrometry using electronic ionization and self-ion/molecule reaction method to determine methoxyacetophenone isomers in one drop of water.

A novel analytical technique termed drop-to-drop solvent microextraction (DDSME) was developed to determine three methoxyacetophenone isomers in one drop of water, which were then detected by gas chromatography/mass spectrometry using electronic ionization mass spectrometry for quantification analysis and self-ion/molecule reaction/tandem mass spectrometry for isomer differentiation. The best optimum parameters for the DDSME technique were as follows: extraction time, 5 min; using toluene as the extraction solvent; volume of extraction solvent, 0.5 microL and no salt addition. The advantages of this method are rapidity, convenience, ease of operation, simplicity of the device, and extremely little solvent and sample consumption. The limit of detection (LOD) for this technique was 1 ng/mL. The relative standard deviation was less than 2.6% (n = 5). The linear range of the calibration curve of DDSME is from 0.01 to 5 microg/mL with correlation coefficient (r2) of >0.954. In the comparison of the LOD of DDSME with other sample pretreatment methods including liquid/liquid extraction (LLE), single-drop microextraction (SDME), solid-phase microextraction (SPME), and liquid-phase microextraction (LPME) using a dual gauge microsyringe with hollow fiber methods, this method shows much better in sensitivity than the LLE (25 ng/mL) and it is compatible with SDME (0.5 ng/mL), SPME (0.5 ng/mL), and LPME using a dual gauge microsyringe with a hollow fiber (1 ng/mL). However, DDSME was more convenient than the LPME using a dual gauge microsyringe with a hollow fiber method and much lower cost than the SPME technique.

Acetophenones↗

Supercritical fluid extraction of steroids from biological samples and first experience with solid-phase microextraction-liquid chromatography.

Modern extraction techniques, supercritical fluid extraction (SFE) and solid-phase microextraction (SPME) were used for isolation of four corticosteroids from biological matrices. SFE was applied for extraction from solid matrices--hydromatrix and pig muscle. The effects of various extraction conditions were studied. Good recoveries of corticosteroids from hydromatrix were obtained under moderate extraction conditions and without modification of carbon dioxide. On the contrary, the best recoveries from spiked pig muscle were obtained with modified carbon dioxide. SPME was used for extraction from liquid samples--water and urine. The eventuality of the use of this fast solvent-free technique in steroid analysis is demonstrated. Several extraction conditions were optimized. Extracted steroids were analyzed by HPLC-UV and a special SPME-HPLC interface was used for combination with SPME.

Adrenal Cortex Hormones↗

Automated in-tube solid-phase microextraction-liquid chromatography-electrospray ionization mass spectrometry for the determination of ranitidine.

The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) was evaluated for the determination of ranitidine. In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary column by repeated aspirate/dispense steps. In order to optimize the extraction of ranitidine, several in-tube SPME parameters such as capillary column stationary phase, extraction pH and number and volume of aspirate/dispense steps were investigated. The optimum extraction conditions for ranitidine from aqueous samples were 10 aspirate/dispense steps of 30 microliters of sample in 25 mM Tris-HCl (pH 8.5) with an Omegawax 250 capillary column (60 cm x 0.25 mm I.D., 0.25 micron film thickness). The ranitidine extracted on the capillary column was easily desorbed with methanol, and then transported to the Supelcosil LC-CN column with the mobile phase methanol-2-propanol-5 M ammonium acetate (50:50:1). The ranitidine eluted from the column was determined by ESI-MS in selected ion monitoring mode. In-tube SPME followed by LC-ESI-MS was performed automatically using the HP 1100 autosampler. Each analysis required 16 min, and carryover of ranitidine in this system was below 1%. The calibration curve of ranitidine in the range of 5-1000 ng/ml was linear with a correlation coefficient of 0.9997 (n = 24), and a detection limit at a signal-to-noise ratio of three was ca. 1.4 ng/ml. The within-day and between-day variations in ranitidine analysis were 2.5 and 6.2% (n = 5), respectively. This method was also applied for the analyses of tablet and urine samples.

Anti-Ulcer Agents↗