Introduction to micro-analytical systems: bioanalytical and pharmaceutical applications.

This review presents a brief overview of recent developments in miniaturization of analytical instruments utilizing microfabrication technology. The concept 'Micro-Total Analysis Systems micro-TAS)', also termed 'Lab-on-a-chip', and the latest progresses in the development of microfabricated separation devices and on-chip detection techniques are discussed. Applications of micro-analytical methods to bioanalytical and pharmaceutical studies are also described, including chemical reactions, assays, and analytical separations of biomolecules in micro-scale.

Animals↗

S-layer proteins as supporting scaffoldings for functional lipid membranes.

A great challenge is the coupling of very sensitive microelectronic devices to wet biological systems in the generation of biomimetic sensors. Lipid membranes on solid supports (electrodes or semiconductors) may become the matrix of future bioelectronic devices probing and controlling biomolecular processes for scientific and technical applications. A sufficient electrical isolation between the coupling region and the surrounding electrolyte is mandatory. An attached lipid membrane with integral natural or designed proteins may be the material of choice if the biological components are kept in a proper environment. To retain the fluidity and stability of the lipid membrane and to provide an ion reservoir and space for bulky integral proteins, a separating layer composed of crystalline arrays of monomolecular proteinaceous subunits, termed S-layer, can be self-assembled on metal or semiconductor surfaces. In this way S-layer-supported lipid membranes are biomimetic structures mimicking the supramolecular principle of archeal cell envelopes. These composite architectures may ascend toward exciting new key devices, particularly in fields of membrane protein-based biosensors or lab-on-a-chip technology.

Bacterial Proteins↗

A chip system for size separation of macromolecules and particles by hydrodynamic chromatography.

For the first time, a miniaturized hydrodynamic chromatography chip system has been developed and tested on separation of fluorescent nanospheres and macromolecules. The device can be applied to size characterization of synthetic polymers, biopolymers, and particles, as an attractive alternative to the classical separation methods such as size exclusion chromatography or field-flow fractionation. The main advantages are fast analysis, high separation efficiency, negligible solvent consumption, and easy temperature control. The prototype chip contains a rectangular flat separation channel with dimensions of 1 microm deep and 1000 microm wide, integrated with a 300-pL injector on a silicon substrate. The silicon microtechnology provides precisely defined geometry, high rigidity, and compatibility with organic solvents or high temperature. All flows are pressure driven, and a specific injection system is employed to avoid excessive sample loading times, demonstrating an alternative way of lab-on-a-chip design. Separations obtained in 3 min show the high performance of the device and are also the first demonstration of flat channel hydrodynamic chromatography in practice.

Chromatography, Liquid↗

Integrated microfluidic system enabling (bio)chemical reactions with on-line MALDI-TOF mass spectrometry.

A continuous flow micro total analysis system (micro-TAS) consisting of an on-chip microfluidic device connected to a matrix assisted laser desorption ionization [MALDI] time-of-flight [TOF] mass spectrometer (MS) as an analytical screening system is presented. Reaction microchannels and inlet/outlet reservoirs were fabricated by powderblasting on glass wafers that were then bonded to silicon substrates. The novel lab-on-a-chip was realized by integrating the microdevice with a MALDI-TOFMS standard sample plate used as carrier to get the microfluidic device in the MALDI instrument. A novel pressure-driven pumping mechanism using the vacuum of the instrument as a driving force induces flow in the reaction microchannel in a self-activating way. Organic syntheses as well as biochemical reactions are carried out entirely inside the MALDI-MS ionization vacuum chamber and analyzed on-line by MALDI-TOFMS in real time. The effectiveness of the micro-TAS system has been successfully demonstrated with several examples of (bio)chemical reactions.

Amino Acid Sequence↗

Cambridge Healthtech Institute's Third Annual Conference on Lab-on-a-Chip and Microarrays. 22-24 January 2001, Zurich, Switzerland.

Cambridge Healthtech Institute's Third Annual Conference on Lab-on-a-Chip and Microarray technology covered the latest advances in this technology and applications in life sciences. Highlights of the meetings are reported briefly with emphasis on applications in genomics, drug discovery and molecular diagnostics. There was an emphasis on microfluidics because of the wide applications in laboratory and drug discovery. The lab-on-a-chip provides the facilities of a complete laboratory in a hand-held miniature device. Several microarray systems have been used for hybridisation and detection techniques. Oligonucleotide scanning arrays provide a versatile tool for the analysis of nucleic acid interactions and provide a platform for improving the array-based methods for investigation of antisense therapeutics. A method for analysing combinatorial DNA arrays using oligonucleotide-modified gold nanoparticle probes and a conventional scanner has considerable potential in molecular diagnostics. Various applications of microarray technology for high-throughput screening in drug discovery and single nucleotide polymorphisms (SNP) analysis were discussed. Protein chips have important applications in proteomics. With the considerable amount of data generated by the different technologies using microarrays, it is obvious that the reading of the information and its interpretation and management through the use of bioinformatics is essential. Various techniques for data analysis were presented. Biochip and microarray technology has an essential role to play in the evolving trends in healthcare, which integrate diagnosis with prevention/treatment and emphasise personalised medicines.

Computational Biology↗

Lab-on-a-chip for drug development.

Significant advances have been made in the development of micro-scale technologies for biomedical and drug discovery applications. The first generation of microfluidics-based analytical devices have been designed and are already functional. Microfluidic devices offer unique advantages in sample handling, reagent mixing, separation, and detection. We introduce and review microfluidic concepts, microconstruction techniques, and methods such as flow-injection analysis, electrokinesis, and cell manipulation. Advances in micro-device technology for proteomics, sample preconditioning, immunoassays, electrospray ionization mass spectrometry, and polymerase chain reaction are also reviewed.

Animals↗

DNA detection by integrable electronics.

This paper presents a new electronic methodology to detect DNA hybridization for rapid identification of diseases, as well as food and environmental monitoring on a genetic base. The proposed solution exploits a new (electrical) capacitive measurement circuit, not requiring any prior labeling of the DNA (as it is often the case with the commonly employed optical detection). The sensitivity, the reliability, and the reproducibility of this device have been evaluated by experiments performed with a (non-integrated) prototype implementation, easily integrable in IC and/or micro-fabricated lab-on-a-chip.

Adsorption↗

Design and fabrication of a silica on silicon integrated optical biochip as a fluorescence microarray platform.

Previous research into the use of Flame Hydrolysis Deposition (FHD) of glasses in integrated optics has focused on the successful commercial exploitation of low cost optical devices within the field of telecommunications and optoelectronics. Recently we have sought to apply these fabrication technologies to the development of optical biochips, utilising their ability to be integrated with microfluidics as a 'Lab-on-a-chip' platform. In this paper, we carry this development forward by seeking to create a microarray of integrated optical sensing elements, addressed using a glass-polymer hybrid technology in which poly(dimethylsiloxane), PDMS, is used as an elastomeric packaging over-layer. In particular, we describe the wide range of modelling and microfabrication processes required for the successful manufacture, integration and packaging of such arrays. The integration of both optical and fluidic circuits in this device avoids precise alignment requirements and results in a compact, robust and reliable device. Finally, in this paper, we describe the implementation of a pumping system for delivering small amounts of fluid across the array together with an optical signal treatment.

Carbocyanines↗

Electrically actuated, pressure-driven microfluidic pumps.

In order to make the lab-on-a-chip concept a reality, it is desirable to have an integrated component capable of pumping fluids through microchannels. We have developed novel, electrically actuated micropumps and have integrated them with microfluidic systems. These devices utilize the build-up of electrolysis gases to achieve pressure-driven pumping, only require small voltages (approximately 10 V), and have approximate dimensions of 5 cm x 3 cm x 2 cm. Furthermore, these micropumps are composed of relatively inexpensive materials, and the reversible sealability of their poly(dimethylsiloxane) body to different microfluidic arrays enables repeated uses of the same pump. Under an applied potential of 10 V, three different micropumps had average flow rates of 8-13 microL min(-1) for water being pumped through five different 2 cm-long, 5500 microm(2) cross-sectional-area channels in poly(methyl methacrylate), in approximate agreement with predicted pump rates. We have also evaluated pump operation at the lower applied potential of 8 V and observed an average flow rate of 6.1 microL min(-1) for a pump-channel system. The current micropump design is capable of sustaining pumping pressures in the range of 300 kPa. The various advantages of these micropumps make them well suited for use in lab-on-a-chip analysis techniques.

Microcomputers↗

Low-voltage electroosmosis pump for stand-alone microfluidics devices.

Two types of low-voltage electroosmosis pumps were developed using microfabrication technology for usage in handy or stand-alone applications of the micrototal analysis systems (micro-TAS) and the lab-on-a-chip. This was done by making a thin (< 1 microm) region in the flow path and by only applying voltages near this thin region using electrodes inserted into the flow path. The inserted electrodes must be free from bubble formation and be gas-tight in order to avoid pressure leakage. For these electrodes, Ag/AgCl or a gel salt bridge was used. For patterning the gel on the chip, a hydrophilic photopolymerization gel and a photolithographic technique were optimized for producing a gel with higher electric conductivity and higher mechanical strength. For high flow rate application, wide (33.2 mm) and thin (400 nm) pumping channels were compacted into a 1 mm x 6 mm area by folding. This pump achieves an 800 Pa static pressure and a flow of 415 nL/min at 10 V. For high-pressure application, a pump was designed with the thin and thick regions in series and positive and negative electrodes were inserted between them alternatively. This pump could increase the pumping pressure without increasing the supply voltage. A pump with 10-stage connections generated a pressure of 25 kPa at 10 V.

Acrylic Resins↗

A micromachined capillary electrophoresis chip with fully integrated electrodes for separation and electrochemical detection.

A novel analytical microsystem with fully integrated electrodes for electrophoresis and amperometrical detection is described. With respect to the lab-on-a-chip concept a capillary electrophoresis (CE) microsystem has been fabricated with a total of six gold electrodes for sample injection, separation and electrochemical detection using standard microfabrication technologies. The device is a ready-to-use system that does not need any extra mechanical apparatus for electrode insertion. The CE-chip has successfully been tested by measuring hydrogen peroxide, ascorbic acid and uric acid simultaneously. All three oxidizable species could be detected in less than 70 s. Glucose was detected by performing an enzymatic reaction along the separation channel. The microsystem showed a very good reproducibility.

Ascorbic Acid↗

Levitation and movement of human tumor cells using a printed circuit board device based on software-controlled dielectrophoresis.

In this study we describe an original, efficient, and innovative printed circuit board (PCB) device able to generate dielectrophoresis-based, software-controlled cages that can be moved to any place inside a microchamber. Depending on their dielectrophoretic properties, eukaryotic cells can be "entrapped" in cages and moved under software control. The main conclusion gathered from the experimental data reported is that the PCB device based on dielectrophoresis permits levitation and movement of different tumor cells at different dielectrophoresis conditions. The results presented herein are therefore the basis for experiments aimed at forced interactions or separation of eukaryotic cells using "lab-on-a-chip." In fact, because many cages can be controlled at the same time, and two or more cages can be forced to share the same or a different location, it is possible, in principle, either to bring in contact cells of a differing histotype or to separate them.

Animals↗

Electrophoresis in microfabricated devices using photopolymerized polyacrylamide gels and electrode-defined sample injection.

Microfabrication techniques have become increasingly popular in the development of the next generation of DNA analysis systems. While significant progress has been reported by many researchers, complete microfabricated integrated DNA analysis devices are still in the earliest stages of development. Most miniaturized analysis systems have incorporated noncross-linked polymer solutions as the separation medium of choice and the operation of these systems necessitates the use of high electric fields and long separation lengths. In this paper, we present two techniques that may help alleviate this problem and accelerate the development of the so-called 'lab-on-a-chip' systems. We present the use of photodefinable polyacrylamide gels as a sieving medium for DNA electrophoresis. These gels offer the significant advantages of faster curing times, locally controlled gel interface, and simpler handling over chemically polymerized gels. We also introduce an electrode-defined sample compaction and injection technique. This technique helps achieve sample compaction without migration into the gel and offers significant control over the size and application of the sample plug. The use of these technologies for double-stranded DNA separations in microfabricated separation systems is demonstrated.

Acrylic Resins↗

Continuous cell partitioning using an aqueous two-phase flow system in microfluidic devices.

We present a novel microfluidic system in which an aqueous two-phase laminar flow is stably formed, and the continuous partitioning of relatively large cells can be performed, eliminating the influence of gravity. In this study, plant cell aggregates whose diameters were 37-96 microm were used as model particles. We first performed cell partitioning using a simple straight microchannel having two inlets and two outlets and examined the effects of the flow rate and the phase width on partitioning efficiency. Second, by using a microchannel with a pinched segment, the partitioning efficiency was successfully improved. This microscale aqueous two-phase flow system can further be incorporated into micro total analysis systems (microTAS) or lab-on-a-chip technology, owing to its simplicity, applicability, and biocompatibility.

Cell Aggregation↗

Microfabricated capillary electrophoresis amino acid chirality analyzer for extraterrestrial exploration.

Chiral separations of fluorescein isothiocyanate-labeled amino acids have been performed on a microfabricated capillary electrophoresis chip to explore the feasibility of using such devices to analyze for extinct or extant life signs in extraterrestrial environments. The test system consists of a folded electrophoresis channel (19.0 cm long x 150 microns wide x 20 microns deep) that was photolithographically fabricated in a 10-cm-diameter glass wafer sandwich, coupled to a laser-excited confocal fluorescence detection apparatus providing subattomole sensitivity. Using a sodium dodecyl sulfate/gamma-cyclodextrin pH 10.0 carbonate electrophoresis buffer and a separation voltage of 550 V/cm at 10 degrees C, baseline resolution was observed for Val, Ala, Glu, and Asp enantiomers and Gly in only 4 min. Enantiomeric ratios were determined for amino acids extracted from the Murchison meteorite, and these values closely matched values determined by HPLC. These results demonstrate the feasibility of using microfabricated lab-on-a-chip systems to analyze extraterrestrial samples for amino acids.

Amino Acids↗

Lab-on-a-chip: applications in proteomics.

Recent advances in chip-based separation of proteins provide methods that are faster and more convenient than conventional gel electrophoresis. Rapid and automated protein sizing on a chip is at the commercial stage and first attempts have been made to perform two-dimensional separation on a chip. Numerous designs have been described to interface a microfluidic chip to a mass spectrometer. Impressive integration efforts are demonstrated by the ability to perform on-chip trypsin digestion, separation and injection into a mass spectrometer with a single device.

Animals↗

Selective ion extraction: a separation method for microfluidic devices.

A separation concept, selective ion extraction (SIE), is proposed on the basis of the combination of hydrodynamic and electrokinetic flow controls in microfluidic devices. Using a control system with multiple pressure and voltage sources, the hydrodynamic flow and electric field in any section of the microfluidic network can be set to desired values. Mixtures of compounds sent into a T-junction on a chip can be completely separated into different channels on the basis of their electrophoretic mobilities. A simple velocity balance model proved useful for predicting the voltage and pressure settings needed for separation. SIE provides a highly efficient separation with minimal additional dispersion. It is an ideal technique for high-throughput screening systems and demonstrates the power of lab-on-a-chip systems.

Journal Article↗

Interconnected reversible lab-on-a-chip technology.

Interconnected lab-on-a-chip modules with minimal dead volume have been developed resulting in the 'plug and play' concept based upon a reversible bonding process. This paper describes the detail of a chip to chip interconnection method, where devices have been aligned and bonded within 15 min and rapidly disassembled in under 5 min. The transport of fluorescein between the chip modules was used as a model microfluidic system and analysed in order to demonstrate the electrophoretic performance of the device and the interconnected junction. Using this technology, in the future different modules for various applications can be developed and interconnected, depending on the required applications. In addition, this simple but rapid method of chip to chip connection overcomes potential problems associated with integrating incompatible materials on one device.

Journal Article↗