Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “High Throughput Screening”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

A generic high-throughput screening assay for kinases: protein kinase a as an example.

A generic high-throughput screening assay based on the scintillation proximity assay technology has been developed for protein kinases. In this assay, the biotinylated (33)P-peptide product is captured onto polylysine Ysi bead via avidin. The scintillation signal measuring the product formation increases linearly with avidin concentration due to effective capture of the product on the bead surface via strong coulombic interactions. This novel assay has been optimized and validated in 384-well microplates. In a pilot screen, a signal-to-noise ratio of 5- to 9-fold and a Z' factor ranging from 0.6 to 0.8 were observed, demonstrating the suitability of this assay for high-throughput screening of random chemical libraries for kinase inhibitors.

Adenosine Triphosphate↗

Functional RNA microarrays for high-throughput screening of antiprotein aptamers.

High-throughput methods for generating aptamer microarrays are described. As a proof-of-principle, the microarrays were used to screen the affinity and specificity of a pool of robotically selected antilysozyme RNA aptamers. Aptamers were transcribed in vitro in reactions supplemented with biotinyl-guanosine 5'-monophosphate, which led to the specific addition of a 5' biotin moiety, and then spotted on streptavidin-coated microarray slides. The aptamers captured target protein in a dose-dependent manner, with linear signal response ranges that covered seven orders of magnitude and a lower limit of detection of 1 pg/mL (70 fM). Aptamers on the microarray retained their specificity for target protein in the presence of a 10,000-fold (w/w) excess of T-4 cell lysate protein. The RNA aptamer microarrays performed comparably to current antibody microarrays and within the clinically relevant ranges of many disease biomarkers. These methods should also prove useful for generating other functional RNA microarrays, including arrays for genomic noncoding RNAs that bind proteins. Integrating RNA aptamer microarray production with the maturing technology for automated in vitro selection of antiprotein aptamers should result in the high-throughput production of proteome chips.

Base Sequence↗

Development of a simple high-throughput screening protocol based on biosynthetic activity of Mycobacterium tuberculosis glutamine synthetase for the identification of novel Inhibitors.

A high-throughput screening protocol has been developed for Mycobacterium tuberculosis glutamine synthetase by quantitative estimation of inorganic phosphate. The K(m) values determined at pH 6.8 are 22 mM for L-glutamic acid, 0.75 mM for NH(4)Cl, 3.25 mM for MgCl(2), and 2.5 mM for adenosine triphosphate. The K(m) value for glutamine is affected significantly by the increase in pH of assay buffer. At the saturating level of the substrate, the enzyme activity at pH 6.8 and 25 degrees C is found to be linear up to 3 h. The reduction of enzyme activity is negligible even in presence of 10% DMSO. The Z' factor and signal-to-noise ratio are found to be 0.75 and 6.18, respectively, when the enzyme is used at 62.5 microg/ml concentration. The IC(50) values obtained at pH 6.8 for both L-methionine S-sulfoximine and DL-phosphothriacin are 500 microM and 30 microM, respectively, which is lowest compared to the values obtained at other pH levels. The Beckman Coulter high-throughput screening platform was found to take 5 h 9 min to complete the screening of 60 plates. For each assay plate, a replica plate is used to normalize the data. Screening of 1164 natural product fractions/extracts and synthetic molecules from an in-house library was able to identify 12 samples as confirmed hits. Altogether, the validation data from screening of a small set of an in-house library coupled with Z' and signal-to-noise values indicate that the protocol is robust for high-throughput screening of a diverse chemical library.

Combinatorial Chemistry Techniques↗

Post-high-throughput screening analysis: an empirical compound prioritization scheme.

An empirical scheme to evaluate and prioritize screening hits from high-throughput screening (HTS) is proposed. Negative scores are given when chemotypes found in the HTS hits are present in annotated databases such as MDDR and WOMBAT or for testing positive in toxicity-related experiments reported in TOXNET. Positive scores were given for higher measured biological activities, for testing negative in toxicity-related literature, and for good overlap when profiled against drug-related properties. Particular emphasis is placed on estimating aqueous solubility to prioritize in vivo experiments. This empirical scheme is given as an illustration to assist the decision-making process in selecting chemotypes and individual compounds for further experimentation, when confronted with multiple hits from high-throughput experiments. The decision-making process is discussed for a set of G-protein coupled receptor antagonists and validated on a literature example for dihydrofolate reductase inhibition.

Automation↗

A high-throughput screen utilizing the fluorescence of riboflavin for identification of lumazine synthase inhibitors.

A high-throughput screening method based on the competitive binding of a lumazine synthase inhibitor and riboflavin to the active site of Schizosaccharomyces pombe lumazine synthase was developed. This assay is sensitive, simple, and robust. During assay development, all of the known active inhibitors tested were positively identified. Preliminary high-throughput screening in 384-well format resulted in a Z factor of 0.7. The approach utilizes a thermodynamic assay to bypass the problems associated with the instabilities of both lumazine synthase substrates that complicate the use of a kinetic assay in a high-throughput format, and it removes the time element from the assay, thus simplifying the procedure.

Binding Sites↗

Chemoenzymatic synthesis and high-throughput screening of an aminoglycoside-polyamine library: identification of high-affinity displacers and DNA-binding ligands.

Chemoenzymatic parallel synthesis and high-throughput screening were employed to develop a multivalent aminoglycoside-polyamine library for use as high-affinity cation-exchange displacers and DNA-binding ligands. Regioselective lipase-catalyzed acylation, followed by chemical aminolysis, was used to generate vinyl carbonate and vinyl carbamate linkers, respectively, of the aminoglycosidic cores. These were further derivatized with polyamines, leading to library generation. A parallel batch-displacement assay was employed to identify the efficacy of the library candidates as potential displacers for protein purification. Using this approach, low-molecular-mass displacers with affinities higher than those previously observed have been identified. The aminoglycoside-polyamine library was also screened for DNA binding efficacy using an ethidium bromide displacement assay. These highly cationic molecules exhibited strong DNA-binding properties and may have potential for enhanced gene delivery.

Aminoglycosides↗

A cell-based cGMP assay useful for ultra-high-throughput screening and identification of modulators of the nitric oxide/cGMP pathway.

We have established a rapid, homogeneous, cell-based, and highly sensitive assay for guanosine 3'-5'-cyclic monophosphate (cGMP) that is suitable for fully automated ultra-high-throughput screening. In this assay system, cGMP production is monitored in living cells via Ca2+ influx through the olfactory cyclic nucleotide-gated cation channel CNGA2, acting as the intracellular cGMP sensor. A stably transfected Chinese hamster ovary (CHO) cell line was generated recombinantly expressing soluble guanylate cyclase, CNGA2, and aequorin as a luminescence indicator for the intracellular calcium concentration. This cell line was used to screen more than 900,000 compounds in an automated ultra-high-throughput screening assay using 1536-well microtiter plates. In this way, we have been able to identify BAY 58-2667, a member of a new class of amino dicarboxylic acids that directly activate soluble guanylate cyclase. The assay system allows the real-time cGMP detection within living cells and makes it possible to screen for activators and inhibitors of enzymes involved in the nitric oxide/cGMP pathway.

Animals↗

High-throughput screening with immobilized metal ion affinity-based fluorescence polarization detection, a homogeneous assay for protein kinases.

Protein kinases are one of the most important target classes in high-throughput screening today. The use of generic assay technologies facilitates assay development for new targets and decreases the time needed for implementation of assays in robotic screening. For tyrosine kinases, several generic assay technology platforms are available. These technologies make use of high-affinity antibodies that discriminate between phosphorylated tyrosines and non-phosphorylated tyrosines. Similar generic antibodies specific for phosphoserine or phosphothreonine are lacking. Recently, a non-antibody-based fluorescence polarization assay for protein kinases has become available, called IMAP (Molecular Devices, Sunnyvale, CA). In this assay, a fluorescently labeled peptide substrate that is phosphorylated by kinase is captured on metal-derivatized nanoparticles. We have evaluated IMAP in high-throughput screening, and compared this technology with a competition fluorescence polarization immunoassay based on an antibody specific for a phosphorylated peptide substrate. A random collection of >250000 compounds was screened with the two assays. Fluorescent library compounds were identified by calculation of fluorescence intensity values from the screening data, and by assaying in the absence of fluorescent reagents. Fluorescence polarization artifacts were filtered out further by testing in an ELISA-based kinase assay. Our data show that IMAP is a robust technology for high-throughput screening of kinase targets, and suggest that it is less susceptible to fluorescence polarization artifacts than the competition fluorescence polarization immunoassay.

Artifacts↗

High-throughput and ultra-high-throughput screening: solution- and cell-based approaches.

The trend towards assay miniaturization for high-throughput and ultra-high-throughput screening continues to spur development of homogeneous, fluorescence-based assays in higher density, smaller volume microplate formats. Recently, first-generation microfluidic devices have been designed for performing continuous-flow biochemical and cell-based assays. These devices provide orders-of-magnitude reduction in reagent consumption, and offer the potential for implementing high-throughput screening in formats that integrate up-front compound handling with unique assay functionality.

Animals↗

Beta galactosidase enzyme fragment complementation as a high-throughput screening protease technology.

The authors describe a homogeneous, high-throughput screening (HTS) assay for measuring protease activity and detection of inhibitors. The assay comprises a cyclic beta-galactosidase (beta-gal) enzyme donor peptide (ED) containing a protease-selective cleavage sequence. Alone, the cyclic peptide is inactive, but when linearized following protease cleavage, ED complements with beta-gal enzyme acceptor forming active beta-gal enzyme. This then catalyzes the formation of either fluorescent or chemiluminescent products, with beta-gal turnover providing a highly amplified signal, and thus an assay technology of high sensitivity. To demonstrate the utility of the technology, an EFC assay was developed to measure the activity of 2, caspase 3 and beta-secretase. Using a cyclic ED containing the caspase 3 substrate sequence, DEVD, the EFC assay signal was linear with respect to caspase 3 concentration. The assay was very sensitive, being able to detect activity at low picogram amounts of caspase 3. For the beta-secretase (BACE) EFC assay, a cyclic ED containing the Swedish mutant cleavage site of amyloid precursor protein (APP), SEVNLDAEFK, was used. In a similar fashion to the caspase 3 assay, the signal induced by BACE activity was linear with respect to enzyme concentration and was highly sensitive, being able to detect nanogram quantities of BACE. The assay was also more sensitive than a commercially available FRET-based assay of BACE activity. It is concluded that the EFC protease assay is a simple, flexible, and sensitive technology for HTS of proteases.

Amino Acid Sequence↗

A new pooling strategy for high-throughput screening: the Shifted Transversal Design.

BACKGROUND: In binary high-throughput screening projects where the goal is the identification of low-frequency events, beyond the obvious issue of efficiency, false positives and false negatives are a major concern. Pooling constitutes a natural solution: it reduces the number of tests, while providing critical duplication of the individual experiments, thereby correcting for experimental noise. The main difficulty consists in designing the pools in a manner that is both efficient and robust: few pools should be necessary to correct the errors and identify the positives, yet the experiment should not be too vulnerable to biological shakiness. For example, some information should still be obtained even if there are slightly more positives or errors than expected. This is known as the group testing problem, or pooling problem. RESULTS: In this paper, we present a new non-adaptive combinatorial pooling design: the "shifted transversal design" (STD). It relies on arithmetics, and rests on two intuitive ideas: minimizing the co-occurrence of objects, and constructing pools of constant-sized intersections. We prove that it allows unambiguous decoding of noisy experimental observations. This design is highly flexible, and can be tailored to function robustly in a wide range of experimental settings (i.e., numbers of objects, fractions of positives, and expected error-rates). Furthermore, we show that our design compares favorably, in terms of efficiency, to the previously described non-adaptive combinatorial pooling designs. CONCLUSION: This method is currently being validated by field-testing in the context of yeast-two-hybrid interactome mapping, in collaboration with Marc Vidal's lab at the Dana Farber Cancer Institute. Many similar projects could benefit from using the Shifted Transversal Design.

Algorithms↗

Integration of a rapid automated solubility classification into early validation of hits obtained by high throughput screening.

Besides the structural verification of hits generated by high throughput screening also the determination of physicochemical properties is essential for an efficient lead identification. Especially solubility is fundamental for the correct planning and interpretation of experiments. We describe the set up of a fast automated solubility test within our existing workflow for hit validation to assure compound identity and purity. 384-Well plates with hit validation compound solution are used for analysis employing liquid chromatography and mass spectrometry (LC/MS). The remaining compound solution was used for a fast automated solubility classification employing a nephelometer integrated into a Tecan robotic workstation. Thereby 9000 compounds were classified as poorly- and well-soluble. This rapid and simple test does not require any additional amount of sample or sample processing than before but provides additional information on the hits at an early stage of lead identification. Validated by a more detailed nephelometric analysis for 500 out of the 9000 compounds in different buffer systems this simple test has shown to produce relevant data.

Automation↗

NMR-based quality control approach for the identification of false positives and false negatives in high throughput screening.

The quality of the data generated in a high throughput screening (HTS) run is fundamental for selecting bona fide inhibitors and for ensuring the capture of the full richness of inhibitors present in a chemical library. For this purpose a quality control filter based on three one dimensional (1D) proton NMR experiments is proposed. The approach called SPAM (Solubility, Purity and Aggregation of the Molecule) Filter requires the acquisition of a 1D reference spectrum, a WaterLOGSY spectrum and/or a selective longitudinal relaxation filter spectrum for the identified hits dissolved in aqueous solution and in the presence of a water soluble reference molecule. This palette of experiments permits the rapid characterization of the identity, purity, solubility and aggregation state of the active compound. This knowledge is crucial for deriving accurate IC(50) and K(1) values of the inhibitors, for identifying false negatives and for detecting promiscuous inhibitors. Only compounds that pass through the SPAM Filter can be considered as starting points for medicinal chemistry efforts directed toward lead optimization. Examples of this approach in the identification of false positives in a screening run against the enzyme thymidine phosphorylase (TP) and the rescue of a false negative in a screening run against the Ser/Thr kinase AKT1 are presented.

Algorithms↗

Multiscale and Bayesian approaches to data analysis in genomics high-throughput screening.

Tremendous amounts of data are produced by high-throughput screening methods currently employed in drug discovery and product development. A typical cDNA microarray or oligonucleotide-based gene chip experiment easily generates over 10,000 data points for each array or chip. The challenge of inferring meaningful information is formidable given the size and number of these datasets. This paper reviews the current status of statistical tools available for gene expression analysis, with emphasis on Bayesian approaches and multiscale wavelet filtering. Fundamental concepts of Bayesian and multiscale modeling are discussed from the perspective of their potential to address important issues related to the analysis of gene expression data, such as the fact that genomic data often have non-Gaussian distributions and feature localization and multiple scales in both frequency and measurement dimension. Recent publications in these areas are reviewed. Wavelet filtering and the advantages of multiscale methods are demonstrated by application to publicly available gene expression data from the National Cancer Institute (NCI). Multiscale methods, including multiscale principal component analysis (MSPCA), are applied to extract gene subsets and to visualize data in multidimensions for comparisons. Similarity in cell lines and gene selection are effectively visualized and quantitatively compared.

Animals↗

The expression of recombinant human LOX-1 and identifying its mimic ligands by fluorescence polarization-based high throughput screening.

Lectin-like oxidized low-density lipoprotein receptor-1 (LOX-1) was identified as a major receptor for oxidized low-density lipoprotein (oxLDL) in endothelial cells. LOX-1 critically mediates the endothelial dysfunction and the progression of atherosclerosis by oxLDL stimulation. It might be an important target for vascular endothelium. In order to obtain human LOX-1 and identify its mimic ligand for facilitating the study of LOX-1 function, a recombinant plasmid pPIC9K-His-hLOX-1 was structured and expressed human LOX-1 in Pichia pastoris GS115. Western blot analysis ensured the expressed recombinant human LOX-1 protein and a receptor-ligand binding assay showed that it had high binding affinity with oxLDL. With this receptor protein, a competitive fluorescence polarization-based high throughput screening method was established in a 384-well microplate to isolate the mimic ligands of human LOX-1. The evaluating parameter Z' value of 0.72 for this method showed that fluorescence polarization-based high throughput screening assay was robust and the results had a high reliability. By the fluorescence polarization-based high throughput screening assay, a total of 20,316 chemicals were screened, and 2 chemicals were identified that they have a high affinity with human LOX-1. Competitive uptake DiI-oxLDL assay by human LOX-1 transfected CHO-K1 cells further confirmed that two chemicals block the uptake of DiI-oxLDL. And the preliminary results indicated that isolated mimic ligands may act as a function of antagonist. The discovery of human LOX-1 mimic ligand would benefit to further study the function of LOX-1 and identify a novel avenue for prevention and treatment atherosclerosis.

Animals↗

Identification of novel small-molecule inhibitors for human transketolase by high-throughput screening with fluorescent intensity (FLINT) assay.

The metabolic enzyme transketolase (TK) plays a crucial role in tumor cell nucleic acid synthesis, using glucose through the elevated nonoxidative pentose phosphate pathway (PPP). Identification of inhibitors specifically targeting TK and preventing the nonoxidative PPP from generating the RNA ribose precursor, ribose-5-phosphate, provides a novel approach for developing effective anticancer therapeutic agents. The full-length human transketolase gene was cloned and expressed in Escherichia coli and the recombinant human transketolase protein purified to homogeneity. A fluorescent intensity (FLINT) assay was developed and optimized. Library compounds were screened in a high-throughput screening (HTS) campaign using the FLINT assay. Fifty-four initial hits were identified. Among them, 2 scaffolds with high selectivity, ideal physiochemical properties, and low molecular weight were selected for lead optimization studies. These compounds specifically inhibited in vitro TK enzyme activity and suppressed tumor cell proliferation in at least 3 cancer cell lines: SW620, LS174T, and MIA PaCa-2. Identification of these active scaffolds represents a good starting point for development of drugs specifically targeting TK and the nonoxidative PPP for cancer therapy.

Cell Line, Tumor↗

Development of a complex scintillation proximity assay for high-throughput screening of PPARgamma modulators.

AIM: To develop a complex high-throughput screening (HTS) assay based on scintillation proximity assay (SPA) technology for identification of novel peroxisome proliferator-activated receptor gamma (PPARgamma) modulators. METHODS: Full-length PPARgamma and retinoid X receptor alpha (RXRalpha), biotinylated PPAR response element (PPRE), [3H]BRL49653 and streptavidin-coated FlashPlate or microbead were used to develop an HTS assay based on SPA technology. This 'ABCDE' method was validated against conventional hydroxyapatite (HA) assay and applied to large-scale screening of 16,000 synthetic compounds and natural product extracts. RESULTS: (1) IC50 values of positive control compounds (BRL49653 and troglitazone) obtained from the 'ABCDE' method and HA assay were comparable and consistent with those reported elsewhere; (2) Approximately 178 compounds, showing more than 70% competitive inhibition on BRL49653 binding to PPARgamma, were identified initially by the 'ABCDE' method (microbead); (3) Secondary screening using FlashPlate and cross-reactivity studies with RARalpha, beta, gamma and RXRalpha,beta, gamma confirmed that 12 compounds possessed specific PPARgamma binding properties including 2 with IC50 values less than 0.5 micromol/L and novel chemical structures. CONCLUSIONS: The 'ABCDE' method using either FlashPlate or microbead, is a highly efficient, automatable, and robust tool to screen potential PPARgamma modulators in HTS setting. Its application may be expanded to other nuclear receptors that form heterodimers upon activation.

Chromans↗

High-throughput screening of historic collections: observations on file size, biological targets, and file diversity.

At Pfizer Central Research, high-throughput screening has been an important source of new leads for drug discovery for a decade. Our experience with over 150 high-throughput screens can address questions about necessary file size, how well particular biological targets fare (with particular reference to protein-protein interactions), and what file diversity means in practice.

Databases, Factual↗