Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Examination Tables”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

In vivo strain measurements from hardware and lamina during spine fusion.

Currently, spine fusion is determined using radiography and clinical evaluation. There are discrepancies between radiographic evidence and direct measurements of fusion, such as operative exploration and biomechanical or histological measurements. In order to facilitate the rapid return of patients to normal activities, a monitoring technique to accurately detect fusion in vivo and to prevent overload during the postoperative period would be useful. The objectives of this study were to develop an implantable monitoring system consisting of CPC-coated strain gauges and a radio transmitter to detect the onset of fusion and measure strain during postsurgical activities. A patient underwent anterior release and fusion, followed by posterior instrumentation and fusion with segmental spinal instrumentation. Four strain gauges were placed during surgery. One was attached to the left-side rod and one to each of the lamina at T9, T10, and T11. An externally powered implanted radio transmitter attached to the gauges was placed in a subcutaneous pouch. Strains were monitored weekly and tabulated during various activities for 7 months. Peak strains during twisting and bending were tabulated to detect the onset of fusion. Strains were also recorded during activities such as climbing off an examination table, rising from a chair, and climbing stairs. Strains collected from the left rod indicated that, immediately postoperatively, it was loaded at acceptable levels. The largest and most consistent strain changes measured from the lamina were recorded during twisting.

Adolescent↗

Cerebrovascular regulation and vasoneuronal coupling.

Maintenance of cerebral perfusion pressure is a prerequisite for the prevention of cerebral ischemia. Physiological fluctuations in systemic perfusion pressure are compensated by cerebrovascular autoregulation. Cerebral hypoperfusion could result from (1) systemic hemodynamic failure (eg, distal to severe arterial stenosis), overcharging the vasoregulatory capacity; (2) dysfunction and exhaustion of cerebrovascular autoregulation; or (3) both. Ultrasound offers an excellent temporal resolution, is noninvasive, and is easily applicable for follow-up investigations. Despite its poor spatial resolution, transcranial Doppler sonography has been used for determination of cerebral perfusion reserve studies measuring cerebral blood flow velocity (CBFV) during hypercapnia or application of vasoactive agents (eg, acetazolamide). This approach evaluates vasomotor regulation in patients with hemodynamic compromise distal to severe stenosis or occlusion of the brain supplying arteries. Monitoring CBFV during tilt table examinations directly measures cerebral autoregulation. In patients with systemic orthostatic hypotension, maintainance or failure of cerebrovascular compensation and, even more importantly, cerebrovascular dysautoregulation, despite normal systemic blood pressure regulation, may be demonstrated. Vasoneuronal coupling is reflected by CBFV variations during appropriate neuronal stimulation. Neuronal dysfunction is associated with CBFV abnormalities as exemplified by preconditions of focal cerebral dysfunction in the posterior cerebral artery (PCA) in migraineurs with aura, where massive alteration of vasoneuronal coupling and ischemia is threatening during spreading depression. A highly significant asymmetric gain of vasoneuronal coupling in the interictal state may act as a trigger mechanism in these patients. Testing for vasoneuronal coupling within the middle cerebral artery (MCA) territory is more difficult due to the poor spatial resolution with various neuronal stimuli (eg, motorsensory or cognitive paradigms), only eliciting local neuronal areas underrepresented in the MCA CBFV global changes. However, motor stimulation evoked CBFV may be used to indicate dysintegration of vasoneuronal coupling in the course of acute cerebral ischemia with sensorimotor hemiparesis and, moreover, seems to be of prognostic value regarding the motor deficit.

Blood Flow Velocity↗

Case reports and studies of paraneoplastic hypotension: abnormal low pressure baroreceptor responses.

Intrathoracic stretch receptors regulate adjustments of the vasculature to gravitational changes and influence urinary water and solute excretion. Few reports of pathologic states involving interruption of these regulatory mechanisms have appeared. Two patients with orthostatic hypotenstion related to advanced intrathoracic carcinoma were studied, utilizing tilt-table examinations and immersion of the entire body in water to test the function of their intrathoracic baroreceptor reflex arcs. Both patients showed abnormalities of antidiuretic hormone level and sodium excretion as compared with normal controls. This suggests that total immersion is a safe and convenient test of the low-pressure baroreceptor system in patients with suspected dysfunction. Three patients are also reported whose charts were reviewed posthumously. Although they were not tested in the laboratory, their clinical data suggest that they too had been suffering from an interference with the transmission of impulses from the intrathoracic receptors.

Adult↗

Multicontrast sequences with continuous table motion: a novel acquisition technique for extended field of view imaging.

A novel acquisition technique called multicontrast imaging is presented that provides multiple datasets of different image contrasts covering an extended field of view within one measurement procedure. The technique uses a continuously moving table and is based on the repetitive acquisition of axial volume sections while the patient moves through the scanner once. To compensate for the table motion during the measurement, adaptive slice shifting is applied. Multicontrast imaging is designed to combine the comfort of a moving table examination with the high time efficiency of a multitask protocol and can be used for generating differences in both contrast and spatial parameters of the acquired data. The technique and its properties are demonstrated on healthy human volunteers.

Humans↗

Reproducibility of manual pressure force on provocation of the sacroiliac joint.

BACKGROUND AND PURPOSE: Previous studies of pain-provocation sacroiliac (SI) joint tests have revealed conflicting results. The aim of the present study was to evaluate the intra- and inter-test reliability of pressure force applied during distraction test, compression test and pressure on the apex sacralis. METHODS: Seventeen physiotherapists (PTs), median age 43 years and median clinical experience 11 years, all experienced in musculoskeletal evaluation and therapy, participated in the study. Each PT performed each test on the same healthy volunteer for 20 s, on three separate occasions, at intervals of one week using a specially constructed examination table which registered pressure force. RESULTS: The PTs were capable of maintaining a relatively constant pressure force for 20 s. The intra-test reliability was acceptable even though there were individual differences on different occasions between those PTs who used the SI joint tests often and those who seldom or never used them. The inter-test reliability was insufficient. CONCLUSIONS: The findings indicate the advantage of registering pressure force as a complement for standardized methods for pain-provoking tests and when learning provocation tests, since individual variability was considerable.

Adult↗

Image resolution and magnification using a cone beam densitometer: optimizing data acquisition for hip morphometric analysis.

Bone mineral density (BMD) is a primary determinant of hip fracture risk. However, other factors, notably the femoral geometry, can influence hip fracture risk. The purpose of this study was to evaluate the potential of a new cone beam densitometer, the DMS Lexxos, in order to visualise femoral morphometry. Resolution, magnification and distortion were assessed in vitro using a line pair test pattern and a matrix test object. Results were given in comparison with currently available systems: the Hologic Discovery A and the Lunar Prodigy densitometers. The DMS Lexxos image resolution was the same in the longitudinal and transversal directions evaluated between 1.4 and 0.5 line pairs/mm (lps/mm) for an attenuation varying from 25 to 325 mm of Perplex. The longitudinal resolution was evaluated between 0.9 and 0.5 lps/mm with the Hologic Discovery densitometer, and inferior to 0.5 with the Lunar Prodigy; as for transversal resolution, it varied from 0.63 to 0.5 lps/mm and from 0.6 to inferior 0.5 lps/mm, respectively. The image was isotropic without magnification with the GE-Lunar Prodigy, whereas there was only a transversal magnification with the Hologic Discovery device. The magnification was about 1.17% cm(-1 )in the two directions, while increasing the distance of the phantom above the examination table with the Lexxos. This magnification was isotropic without distortion. The magnification could be evaluated from two images taken before and after translation of the C-arm, and a magnification correction could be applied. This method was applied to a phantom and to a human cadaver femoral bone.

Absorptiometry, Photon↗

Subtraction procedure for the registration of tissue perfusion with Doppler ultrasound.

Tissue perfusion, i.e., in muscles or parenchymatous organs, is of both physiological and pathophysiological interest. The measurement of tissue perfusion is an unsolved problem. The Doppler ultrasound method is well suited to this purpose. However, measurements using this technique may be disturbed by movements or vibrations such as heart motion, muscle trembling or vibration of the subsoil (i.e. the examination table). These interfering movements produce Doppler frequencies in the same frequency range as slowly flowing erythrocytes, causing artifacts to appear in the measured data. The goal of this project was to suppress such artifacts with the help of a subtraction procedure. The mathematical theory of this subtraction procedure and its implementation in a newly developed two channel Doppler system are presented. This system was successfully tested on a phantom which is able to generate flow and movement artifacts. Preliminary measurements in the forearms of volunteers showed that movement artifacts can be at least partially suppressed.

Adult↗

Saphenous nerve injury following medial knee joint injection: a case report.

Knee joint injection is a procedure commonly performed for pain management of osteoarthritis. Although several techniques have been described, it is usually performed by either medial or lateral approach with the lower limb extended on the examination table. We present the case of a patient who developed saphenous neuropathy following knee joint injection via medial approach. The clinical picture suggests that the needle pierced the nerve during the procedure. The patient was moderately obese. This is the first case report in the literature of saphenous nerve injury following medial knee joint injection. Practitioners should be aware of this complication in choosing an approach to the knee joint injection, especially when the patient is obese and the anatomic landmarks are obscured.

Adjuvants, Immunologic↗

SOGC clinical practice guidelines. Ultrasound evaluation of first trimester pregnancy complications. Number 161, June 2005.

OBJECTIVES: First, to review normal embryonic development and the sonographic evidence of early pregnancy failure; second, to review sonographic evidence of ectopic pregnancy. OUTCOMES: First, prediction of pregnancy failure, second, sonographic identification of ectopic pregnancy. EVIDENCE: A MEDLINE search and review of bibliographies in identified articles was conducted. VALUES: The evidence was reviewed by the Diagnostic Imaging Committee along with the principal authors. A quality of evidence assessment was undertaken as outlined in the report of the Canadian Task Force on the Periodic Health Examination (Table 1). BENEFITS, HARMS, AND COSTS: Women presenting with first trimester bleeding may be incorrectly diagnosed with a missed abortion and (or) may be inappropriately reassured about viability. Transvaginal ultrasound provides improved resolution allowing description of early embryonic development characteristics. Improvement in the identification of the sonographic landmark of normal embryonic development and awareness of the sonographic risk factors of pregnancy failure may lead to more successful management strategies. Diagnosis of suspected ectopic pregnancy often involves an assessment of both hormonal markers and sonographic features. Maternal morbidity and mortality can be reduced with an early diagnosis of ectopic pregnancy. RECOMMENDATIONS: There is good (class A) evidence that current ultrasound technology can distinguish between normal and abnormal pregnancies in the first trimester. There is good (class A) evidence that transvaginal ultrasound in conjunction with quantitative-HCG can diagnose ectopic pregnancy.

Embryonic Development↗

Choice of surgery for stress incontinence.

OBJECTIVE: To outline the evidence for the efficacy of surgical procedures used for the primary treatment of urinary incontinence. OPTIONS: The range of surgical options available for the primary treatment of urinary incontinence in women. OUTCOMES: The best possible outcomes for women undergoing primary surgery for urinary incontinence. To provide a current understanding of the evidence available as the basis of an informed discussion of the anticipated outcome of surgery. EVIDENCE: A systematic review of clinical trials of the outcomes of primary surgical treatment of urinary incontinence. VALUES: The quality of the evidence is rated using the criteria described by the Canadian Task Force on periodic health examination (Table). BENEFITS, HARMS, AND COSTS: Careful consideration of the surgical options available will result in informed choice, which is essential to the process of determining the most appropriate surgery for a woman. Use of a range of surgeries that have the highest proven efficacy is most likely to result in long-term patient satisfaction.

Journal Article↗

Spinal muscle evaluation using the Sorensen test: a critical appraisal of the literature.

The first test for evaluating the isometric endurance of trunk extensor muscles was described by Hansen in 1964. In 1984, following a study by Biering-Sorensen, this test became known as the "Sorensen test" and gained considerable popularity as a tool reported to predict low back pain within the next year in males. The test consists in measuring the amount of time a person can hold the unsupported upper body in a horizontal prone position with the lower body fixed to the examining table. This test has been used in many studies, either in its original version or as variants. Although its discriminative validity, reproducibility, and safety seem good, debate continues to surround its ability to predict low back pain; in addition, the gender-related difference in position-holding time remains unexplained and the influence of body weight unclear. A contribution of the hip extensor muscles to position holding has been established, but its magnitude remains unknown. The influence of personal factors such as motivation complicates the interpretation of the results. Despite these drawbacks, the Sorensen test has become the tool of reference for evaluating muscle performance in patients with low back pain, most notably before and after rehabilitation programs.

Exercise Test↗

The slippery slope: reducing fall risk in older adults.

Determining fall risk can be a daunting task for the busy clinician, but a simple set of questions and observations at each encounter with the patient can help. Rarely does a complete fall-risk evaluation have to be completed in one visit. Most patients will have a gradual or incremental decline and the evaluation can be performed over time. The clinician should ask the older patient at each visit if he or she has had a fall, is concerned about falling, or is concerned about balance or gait. The clinician should also take notice of the person's mobility at the time of each encounter and observe how the patient enters the office and the examination room. How did the person get on the examination table room? Did the person walk in independently or with the aid of a family member or office staff? By being vigilant in the evaluation of patients at each visit, the office practitioner can more easily identify subtle declines that may lead to disability, falls, and the potential injuries associated with falls. Once at-risk patients are identified, risk factors can be reduced or eliminated and ongoing exercise and fitness programs recommended.

Accidental Falls↗

Body composition assessment by dual-energy x-ray absorptiometry: comparison of prone and supine measurements.

The aim of the study was to assess whether changes in the interposition of body compartments affect the results of body composition measurements by dual-energy x-ray absorptiometry (DEXA) in the fan-beam mode. Thirty healthy subjects underwent two sequential measurements: the first was performed in the supine position as described by the manufacturer, and the second in the prone position. Estimates of body composition were compared between the two measurements. Mean body weight did not differ between measurements ([mean+/-SD] supine vprone, 68.561+/-12.461 v 68.589+/-12.469 kg). Mean bone mineral content (BMC) was lower in the prone position versus the supine position. When the head was excluded, this difference reached statistical significance (supine v prone, 1,738+/-361 v 1,688+/-360 g, P=.0001). The mean fat tissue mass (FTM) was lower and lean tissue mass (LTM) higher in the prone measurements. When the head was excluded, the mean FTM difference between the two measurements became greater (FTM supine v prone, 25.129+/-10.445 v 24.030+/-10.388 kg, P=.0001; LTM supine v prone, 37.309+/-9.357 v 38.246+/-9.150 kg, P=.0001). It is concluded that the positioning of the patient on the examination table affects DEXA body composition measurements by the fan-beam mode. This could imply a lack of accuracy of the method, which may be due to subtle changes in regional tissue depth and fat distribution caused by patient repositioning.

Absorptiometry, Photon↗

The latest in ultrasound: three-dimensional imaging. Part 1.

OBJECTIVE: The state-of-the-art of three-dimensional ultrasound is reviewed to evaluate technological achievements and future possibilities in diagnosis and in the follow-up of medical or invasive therapy. MATERIAL AND METHODS: The problems related to volumetric acquisitions in the tissues of interest to provide three-dimensional images are considered. Three-dimensional images are easier to achieve with computed tomography because the scanning system of this technique is automatic and thus provides sequential slices. The same is true for magnetic resonance imaging which can aquire volumes directly. The problem with ultrasound lies in the fact that the scans are manual and therefore less precise. To obtain three-dimensional images these devices are commonly used: manual scanning probes connected to spatial magnetic evidencers with remote processing; manual scanning probes connected to spatial magnetic evidencers placed on the patient's examination table with processing internal to the ultrasound unit; mechanical probes that can provide volumetric scans; 'matrix' probes. Recent contributions are discussed relative to three-dimensional applications to cardiology (cardiac valve studies), obstetrics (malformations), gynecology (uterine malformations and extensive ovarian disease studies), gastroenterology (diagnosis of pancreatic and hepatoabiliary tumor extent), uro-nephrology (detection of stones, prostatic tumors) and finally in the study of rectal carcinomas. CONCLUSIONS: Nearly all the papers about three-dimensional ultrasound are works in progress because the technique has not been standardized yet and some of its future diagnostic possiblities are difficult to foresee. Moreover, 'matrix' probes are still in the experimental stage. Nevertheless, this technique seems to be able to yield the best results in: fetal malformations; calculating the volumes of normal and diseased organs; the follow-up of masses treated with irradiation/chemotherapy or with alcohol or chemoembolization; the spatial reconstruction of extensive lesions; the detection of small lesions (metastases); the study of some complex functions such as cardiac valve dynamics. But the real problem with three-dimensional sonography is not its efficiency but rather its efficacy, that is which actual role this technique can play in diagnosis and which information it can add to that obtained with two-dimensional imaging.

Humans↗

Modifications of plasma levels of tissue factor pathway inhibitor and endothelin-1 induced by a reverse Trendelenburg position: influence of elastic compression--preliminary results.

PURPOSE: The purpose of this study was to assess the effects of the passive 45-degree reverse Trendelenburg position and graduated compression stockings (GCS) on plasma tissue factor pathway inhibitor (TFPI) and endothelin-1 levels in a group of volunteers. METHODS: Ten healthy subjects lay on an examining table for 30 minutes while baseline measurements were made. The table was then tilted to a 45-degree upright position for 60 minutes, and measurements were repeated. On a different day, subjects were tilted again, but on this occasion they wore thigh-length GCS. Blood was drawn before and 60 minutes after tilting during both sessions, and plasma TFPI and endothelin-1 were obtained. Cross-sectional areas of the calf medial gastrocnemius vein, before and after tilting, were measured by a duplex scanner. RESULTS: Upright tilting induced a significant dilation of the medial gastrocnemius veins that was partially corrected by the use of elastic stockings. Similarly, endothelin-1 levels significantly increased after tilting. The use of GCS did not modify these differences. On the other hand, although TFPI levels were not affected by tilting without stockings, they were significantly elevated after tilting when GCS were used. CONCLUSIONS: Upright passive tilting induces significant dilation of the deep calf veins and is associated with a significant increase in plasma levels of endothelin-1, whereas TFPI levels remain unchanged. The use of elastic stockings reduces the degree of calf distention but does not prevent an increase in endothelin-1. TFPI levels are significantly increased after tilting when GCS are used. This might represent a previously unknown mechanism of action of elastic stockings with interesting potential for deep vein thrombosis prophylaxis. More studies are warranted in a larger series to confirm these results.

Adult↗

[Use of real-time system of portal imaging in the daily monitoring of patients treated by radiotherapy for thoracic cancer].

PURPOSE: Retrospective analysis of the results obtained with daily interactive use of portal imaging for monitoring thoracic cancer radiotherapy. MATERIALS AND METHODS: A Siemens electronic portal imaging system called Beamviewplus was used daily in 15 lung cancer patients for each X-ray field. Out of the 714 expected portal images, 585 (82%), were obtained and printed. RESULTS: We counted 94 errors in the 585 successful controls (16%). Four main classes of errors were identified: irradiation field placement (47 cases, 50%), shielding placement (30 cases, 32%) patient's position on the till examining table (14 cases, 15%), and selection of the energy (3 cases, 3%). Forty percent of these errors were potentially serious in terms of treatment volume and vital organ protection. CONCLUSION: Only portal imaging control could easily detect errors because they occurred randomly. We thus consider the use of this daily system helpful for patient management.

Esophageal Neoplasms↗

Current status of vaginosonography: a world-wide inquiry.

In the last 5 years, vaginosonography has become a routine procedure in obstetrics and gynecology. Many obstetricians, gynecologists, radiologists and ultrasonographers have recognized the advantages of this method. Nearly all manufacturers of ultrasound equipment offer several types of vaginal probes. The rapid spread of vaginosonography has also led to some disadvantages concerning the lack of standardized terminology and image display. In this study, we collected data about the current standards of vaginosonography. To obtain data, questionnaires were sent out to the 1107 Departments of Obstetrics and Gynecology in the FIG0 Registry 1985. In the accompanying letter, the chairman was asked to hand over the questionnaire to the appropriate specialist. The questionnaire was designed to gather information about the personnel performing vaginosonography and the techniques, transducer frequency, position of the patient and image display used. A total of 369 responses were received. Vaginosonographic investigations were performed in 84% of the University Departments of Obstetrics and Gynecology. In 90% of these, vaginosonography was performed by the obstetrician or gynecologist, in 4% by the radiologist and in 6% by the technician. Most departments preferred end-firing transducers. The numbers of electronic and mechanical probes were nearly identical (56% vs. 44%). The preferences for a scanner with a narrow (less than 120 degrees ) or wide angle (more than 120 degrees ) were very similar (53% vs. 47%). More than half of the responders (54%) used a transducer frequency of 5 MHz, while 46% preferred scanners with a frequency between 5.5 and 7.5 MHz. In 55%, the gynecological examination table was considered to be superior to a flat table. Of the responders, 52% projected the apex of the vaginal probe to the bottom of the ultrasound monitor. This was particularly the case in Europe (63%). Questioned about a preference for a particular orientation in the future, an additional 7% voted to change to this mode of image display world-wide. When performing a sagittal section, if the probe was projected to the bottom of the screen, dorsally located to the structures were projected twice as often to the left of the screen as to the right.

Journal Article↗

Extensibility and stiffness of the hamstrings in patients with nonspecific low back pain.

OBJECTIVE: To investigate the extensibility and stiffness of the hamstrings in patients with nonspecific low back pain (LBP). DESIGN: An experimental design. SETTING: A university laboratory for human movement analysis in a department of rehabilitation medicine. PARTICIPANTS: Forty subjects, a patient group (20) and a healthy control group (20). INTERVENTIONS: Subjects laid supine on an examination table with a lift frame, with left leg placed in a sling at the ankle. Straight leg raising, pulling force, and activity of hamstring and back muscles were recorded with electrodes. Patients indicated when they experienced tension or pain. MAIN OUTCOME MEASURES: The lift force, leg excursion, pelvic-femoral angle, first sensation of pain, and the electromyogram of the hamstrings and back muscles measured in an experimental straight-leg raising set-up. RESULTS: The patient group showed a significant restriction in range of motion (ROM) and extensibility of the hamstrings compared with the control group. No significant difference in hamstring muscle stiffness can be assessed between both groups. CONCLUSION: The restricted ROM and the decreased extensibility of the hamstrings in patients with nonspecific LBP is not caused by increased muscle stiffness of the hamstrings, but determined by the stretch tolerance of the patients.

Adult↗