Characterisation of a fungus reference material, and a guide for use.

A reference material consisting of an edible fungus, Cantharellus tubaeformis, with certified levels of Pb, Cd, Zn, Cu, Mn, Cr, Ni, Co and Fe was produced, primarily for use in a project concerning metal determination in common edible fungi. The C. tubaeformis was dried, homogenised and sieved using non-contaminating equipment. It was then mixed thoroughly before bottling in polythene containers. Homogeneity was checked by multiple analysis of a number of containers, and was found to be satisfactory. Each metal was determined by at least two different methods of analysis. A total of ten laboratories participated in the certification process. All the metals analysed in this certified reference material showed good agreement with the levels found in fresh C. tubaeformis, when the difference in water content was accounted for. This indicates that no contamination of the fungus reference material occurred during the production. It is concluded that the 95% confidence interval for the true mean, as defined for the different metals, is of limited value from the user's point of view. Therefore, a more user-oriented way of presenting the results, based on the within- and between-laboratory standard deviations of the certification process, is suggested. These are 95/95% tolerance intervals within which the user's results should fall. Different intervals are given, one of which indicates the largest acceptable difference between duplicates and another for the acceptable range of future means.

Agaricales↗

Prevention of cross-contamination when using microdermabrasion equipment.

This article addresses the concern of cross-contamination with the use of microdermabrasion equipment. After performing microdermabrasion on a patient with acne scarring, the instrument was examined for debris on the plateau of the hand piece. Bloody material was noted, indicating that it is not sufficient to only sterilize the distal cap of the hand piece or to use disposable caps. The hand piece itself must be sterilized to prevent the transmission of infectious particles to the next patient receiving treatment with this equipment.

Dermabrasion↗

Latex and vinyl examination gloves. Quality control procedures and implications for health care workers.

In December 1987, we investigated an increased number of cases of herpetic whitlow in medical intensive care unit nurses who routinely gloved for secretion contact. One particular brand of vinyl examination glove had been used in the medical intensive care unit. Restriction endonuclease mapping established the similarity of employee isolates with one patient isolate of herpes simplex virus type I. When initial viral assay demonstrated 2.5% to 10% penetration of herpes simplex virus type I across unused gloves, an evaluation of glove quality was undertaken. In a 300-mL watertightness test, seven brands of vinyl gloves failed 4% to 28% (average, 11.1%; 132/1200), while seven brands of latex gloves failed 0% to 2.6% (average, 1.4%; 24/1750). The brand of vinyl glove that had been in use in the medical intensive care unit failed 28% of the time. Watertight gloves were then tested for permeability to herpes simplex virus type I. None of the latex gloves failed (n = 1726), while only 10 of the vinyl gloves failed (n = 1068, 0.95%). Extreme variability in glove quality was observed. However, gloves made from intact vinyl may provide similar protectiveness as those made from intact latex. As the demand for gloves increases, emphasis should be placed on the production of plentiful, better quality latex and vinyl gloves.

Disease Outbreaks↗

A randomized crossover study of silver-coated urinary catheters in hospitalized patients.

BACKGROUND: Urinary tract infections (UTIs) account for 30% to 40% of nosocomial infections resulting in morbidity, mortality, and increased length of hospital stay. OBJECTIVE: To assess the efficacy of a silver-alloy, hydrogel-coated latex urinary catheter for the prevention of nosocomial catheter-associated UTIs. METHODS: A 12-month randomized crossover trial compared rates of nosocomial catheter-associated UTI in patients with silver-coated and uncoated catheters. A cost analysis was conducted. RESULTS: There were 343 infections among 27,878 patients (1.23 infections per 100 patients) during 114,368 patient-days (3.00 infections per 1000 patient-days). The relative risk of infection per 1000 patient-days was 0.79 (95% confidence interval, 0.63-0.99; P =.04) for study wards randomized to silver-coated catheters compared with those randomized to uncoated catheters. Infections occurred in 291 of 11,032 catheters used on study units (2.64 infections per 100 catheters). The relative risk of infection per 100 silver-coated catheters used on study wards compared with uncoated catheters was 0.68 (95% confidence interval, 0.54-0.86; P =.001). Fourteen catheter-associated UTIs (4.1%) were complicated by secondary bloodstream infection. One death appeared related to the secondary infection. Estimated hospital cost savings with the use of the silver-coated catheters ranged from $14,456 to $573,293. CONCLUSIONS: The risk of infection declined by 21% among study wards randomized to silver-coated catheters and by 32% among patients in whom silver-coated catheters were used on the wards. Use of the more expensive silver-coated catheter appeared to offer cost savings by preventing excess hospital costs from nosocomial UTI associated with catheter use. Arch Intern Med. 2000;160:3294-3298.

Adult↗

Frequency of infections associated with implanted systems vs cuffed, tunneled Silastic venous catheters in patients with acute leukemia.

A total of 75 central venous catheters were used for prolonged chemotherapy in 39 children with acute lymphocytic leukemia and 21 patients with acute myelocytic leukemia. Infection rates were 2.2 per 100 catheter days with the use of cuffed, tunneled, single-lumen Silastic catheters, 2.0 per 1000 catheter days with cuffed, tunneled, double-lumen Silastic catheters, and 0.5 per 1000 catheter days with the use of implanted venous access systems. Eighty-one percent of catheter sepsis episodes were successfully treated without removal of the catheter. All tunnel infections required withdrawal of the catheter for cure. The microorganisms were gram-positive bacteria in 15%, gram-negative bacteria in 7%, and fungi in 4%. Coagulase-negative staphylococci and Pseudomonas aeruginosa were the most commonly isolated organisms. Three of six fatal sepsis episodes were caused by disseminated fungal infections. We conclude that the use of intracorporeal venous catheter systems in patients with acute lymphocytic leukemia is associated with a lower infection rate than that with cuffed, tunneled Silastic single- or double-lumen catheters and that most septicemias can be cured with antimicrobial therapy without removal of the catheter.

Adolescent↗

Mode of chemotherapy does not affect complications with an implantable venous access device.

BACKGROUND: Few reports have been made regarding the long term safety of implantable venous access devices used for the delivery of chemotherapeutic agents. The authors' goals were to determine the frequency of complications in patients receiving chemotherapy with these devices; to determine whether complications were associated with the mode of chemotherapy delivery (push/bolus or infusional regimens); and to evaluate the influence of other risk factors, including home-based versus hospital-based administration. METHODS: A total of 152 oncology patients at the John L. McClellan Memorial Veterans Administration Medical Center in Little Rock, Arkansas (ages 26-81 years; mean age, 62 years), who underwent surgical placement of an Infus-a-Port (Strato, Inc., Beverly, MA) between May 1, 1992 and May 31, 1994, were evaluated retrospectively for postplacement device complications, such as infection, thrombosis, and mechanical failure. RESULTS: Twenty-seven patients experienced 1 complication each: 17 episodes of device-related sepsis, cellulitis, or fever of unknown origin; 8 episodes of thrombosis or catheter occlusion; 1 episode of drug extravasation; and 1 mechanical failure. Patient age, frequency of port accession, mode of chemotherapy delivery, tumor type, and neutropenia were evaluated as risk factors, but none was statistically significant. Complications were more frequent during the first 90 days after implantation, but they continued to occur throughout the observation period. CONCLUSIONS: Complications attributable to an implantable venous access device were infrequent in this patient population. No differences in complications for patients receiving home-based versus hospital-based chemotherapy administration were noted, opening the possibility of significant time and cost savings with home treatment.

Adult↗

Risks of reusing coronary angioplasty catheters: results of an experimental study.

This experimental study was conducted to evaluate the microbiological and mechanical risks of reusing angioplasty catheters after decontamination and resterilization. The catheters studied were decontaminated in an ultrasound chamber, rinsed, dried, wrapped, and resterilized at 25 or 35 Kgray. Sterility checks performed on catheters cut into three segments concerned bacteria, mushrooms, yeasts, and pyrogens. The surface condition of the balloons was studied by scanning electron microscopy. The mechanical properties analyzed were balloon diameter and bursting pressure and the mean resistance of the catheter body to breakage. Seventy angioplasty catheters of three different types (rapid exchange, coaxial, and on-wire balloon catheter) were tested. Decontamination proved insufficient owing to the persistence of cellular elements on the balloon surface and the presence of pyrogens. Sterility of the material was not ensured with an irradiation of 25 Kgray. It was probable but not certain with 35 Kgray, since an inhibitory effect on micro-organism growth was noted. Mechanical properties were not modified significantly. Our results do not favor the reuse of coronary angioplasty catheters. Better decontamination is desirable but difficult to obtain because of the adhesion of cellular elements to the polymers composing the catheters. Although our results are not necessarily applicable to all resterilization protocols, they indicate that teams desiring to reuse angioplasty material should first test the validity of their procedure for decontamination and resterilization.

Angioplasty, Balloon, Coronary↗

Self-sterilizing and self-cleaning of silicone catheters coated with TiO(2) photocatalyst thin films: a preclinical work.

TiO(2) photocatalysts were successfully coated on silicone catheters or medical tubes by pretreatment of the silicone surface with a sulfuric acid solution (5 M) for 3 h. The TiO(2) film adhered to the silicone substrate strongly against tensile and bending stresses. On the TiO(2)-coated silicone-catheters under UV illumination, both the bleaching of methylene blue dye and the photocatalytic bactericidal effect on Escherichia coli (E. coli) cells were confirmed. Thus, this type of catheter can be sterilized and cleaned simply by irradiation with low-intensity UV light and can, therefore, be useful in the protection from catheter-related bacterial infections.

Coated Materials, Biocompatible↗

An impedance study on admiralty brass dezincification originated by microbiologically influenced corrosion.

In this article we describe a field study of biofouling and microbiologically influenced corrosion (MIC) of admiralty brass heat exchanger tubes in contact with running fresh water on the river Tagus close to Almaraz nuclear power plant in Spain. Dezincification originated by biofouling and MIC was studied using impedance, polarization resistance, gravimetric, scanning electron microscopy (SEM), and X-ray diffraction (XRD) measurements. Close correlation was observed between the biofilms formed and the corrosion process (dezincification) using the different experimental techniques. Impedance data showed a capacitive behavior including two time constants. Kramers-Kronig (KK) transforms were used to validate impedance data. The admiralty tubes' impedance data satisfied the KK relations.

Biofilms↗

Infection control guidelines for the cardiac catheterization laboratory: society guidelines revisited.

In the early years of diagnostic cardiac catheterization, strict sterile precautions were required for cutdown procedures. Thirteen years ago, when the original guidelines were written, the brachial arteriotomy was still frequently utilized, femoral closure devices were uncommon, "implantables," such as intracoronary stents and PFO/ASD closure devices, were in their infancy, and percutaneous valve replacement was not a consideration. In 2005, the cardiac catheterization laboratory is a complex interventional suite with percutaneous access routine and device implantation standard. Despite frequent device implantation, strict sterile precautions are often not observed. Reasons for this include a decline in brachial artery cutdown, limited postprocedure follow-up with few reported infections, limited use of hats and masks in televised cases, and lack of current guidelines. Proper sterile technique has the potential to decrease the patient infection rate. Hand washing remains the most important procedure for preventing infections. Caps, masks, gowns, and gloves help to protect the patient by maintaining a sterile field. Protection of personnel may be accomplished by proper gowning, gloving, and eye wear, disposal of contaminated equipment, and prevention and care of puncture wounds and lacerations. With the potential for acquired disease from blood-borne pathogens, the need for protective measures is as essential in the cardiac catheterization laboratory as is the standard Universal Precautions, which are applied throughout the hospital. All personnel should strongly consider vaccination for hepatitis B. Maintenance of the cardiac catheterization laboratory environment includes appropriate cleaning, limitation of traffic, and adequate ventilation. In an SCAI survey, members recommended an update on guidelines for infection control in the cardiac catheterization laboratory. The following revision of the original 1992 guidelines is written specifically to address the increased utilization of the catheterization laboratory as an interventional suite with device implantation. In this update, infection protection is divided into sections on the patient, the laboratory personnel, and the laboratory environment. Additionally, specific CDC recommendation sections highlight recommendations from other published guidelines.

Antibiotic Prophylaxis↗

Improving the biosafety of cell sorting by adaptation of a cell sorting system to a biosafety cabinet.

BACKGROUND: The jet-in-air cell sorters currently available are not very suitable for sorting potentially biohazardous material under optimal conditions because they do not protect operators and samples as recommended in the guidelines for safe biotechnology. To solve this problem we have adapted a cell sorting system to a special biosafety cabinet that satisfies the requirements for class II cabinets. With aid of this unit, sorting can be performed in conformance with the recommendations for biosafety level 2. METHODS: After integrating a modified fluorescence-activated cell sorter (FACS) Vantage into a special biosafety cabinet, we investigated the influence of the laminar air flow (LAF) inside the cabinet on side stream stability and the analytical precision of the cell sorter. In addition to the routine electronic counting of microparticles, we carried out tests on the containment of aerosols, using T4 bacteriophage as indicators, to demonstrate the efficiency of the biosafety cabinet for sorting experiments performed under biosafety level 2 conditions. RESULTS: The experiments showed that LAF, which is necessary to build up sterile conditions in a biosafety cabinet, does not influence the conditions for side stream stability or the analytical precision of the FACS Vantage cell sorting system. In addition, tests performed to assess aerosol containment during operation of the special biosafety cabinet demonstrated that the cabinet-integrated FACS Vantage unit (CIF) satisfies the conditions for class II cabinets. In the context of gene transfer experiments, the CIF facility was used to sort hematopoietic progenitor cells under biosafety level 2 conditions. CONCLUSIONS: The newly designed biosafety cabinet offers a practical modality for improving biosafety for operators and samples during cell sorting procedures. It can thus also be used for sorting experiments with genetically modified organisms in conformance with current biosafety regulations and guidelines.

Aerosols↗

Comparison study of home catheter cleaning methods.

Three methods of cleaning urinary catheters for reuse at home by clients on intermittent catheterization programs were studied. Reused catheters were collected from clients, autoclaved, and then incubated in a culture of Escherichia coli broth. Three different isolates of E. coli were used at concentrations ranging from 4.8 x 10(5) to 1.0 x 10(8) colony-forming units per milliliter. The catheters were then rinsed with tap water for 1 minute and soaked in one of three cleaning solutions for 30 minutes. The three cleaning solutions studied were 0.6% hydrogen peroxide, bleach in a 1:4 solution with tap water, and betadine in a 1:2 solution with tap water. None of the cleaned catheters showed detectable growth for 48 hours after the cleaning procedure was performed.

Catheters, Indwelling↗

Toxicological, medical and industrial hygiene aspects of glutaraldehyde with particular reference to its biocidal use in cold sterilization procedures.

Aqueous solutions of > or =5% glutaraldehyde (GA) are of moderate acute peroral toxicity and those of < or =2% are of slight toxicity. By single sustained skin contact, aqueous GA solutions of > or =45% are of moderate acute percutaneous toxicity, those of 25% are of slight toxicity and those of </=15% do not present an acute percutaneous hazard. Vapor generated at ambient temperature may cause sensory irritant effects to the eye and respiratory tract, but not acute respiratory tract injury. The 50% decrease in respiratory rate (rd(50)) is 13.86 ppm. A 0.1% solution of GA is not irritating to the eye; the threshold for conjunctival irritation is 0.2% and for corneal injury it is 1.0%. Eye injury is moderate at 2% and severe at > or =5%. Primary skin irritation depends on the duration and contact site, occlusion and solvent. By sustained contact, the threshold for skin irritation is 1%, above which erythema and edema are dose related. With 45% and higher, skin corrosion may occur. There is a low incidence of skin sensitizing reactions, with an eliciting threshold of 0.5% aqueous GA. However, GA is neither phototoxic nor photosensitizing. Subchronic repeated exposure studies by the peroral route show only renal physiological compensatory effects, secondary to reduced water consumption. Repeated skin contact shows only minor skin irritant effects without systemic toxicity. By subchronic vapor exposure, effects are limited to the nasal mucosa at 1.0 ppm, with a no-effect concentration generally at 0.1 ppm. There is no evidence for systemic target organ or tissue toxicity by subchronic repeated exposure by any route. A chronic drinking water study showed an apparent increase, in females only, of large granular cell lymphocytic leukemia but this was not dosage related. This is most likely the result of a modifying effect on the factor(s) responsible for the expression of this commonly occurring rat neoplasm. A chronic (2-year) inhalation toxicity/oncogenicity study showed inflammatory changes in the anterior nasal cavity but no neoplasms or systemic toxicity. In vitro genotoxicity studies--bacterial mutagenicity, forward gene mutation (HGPRT and TK loci), sister chromatid exchange, chromosome aberration, UDS and DNA repair tests--have given variable results, ranging from no effect through to weak positive. In vivo genotoxicity studies--micronucleus, chromosome aberration, dominant lethal and Drosophila tests--generally have shown no activity but one mouse intraperitoneal study showed bone marrow cell chromosome aberrations. Developmental toxicity studies show GA not to be teratogenic, and a two-generation study showed no adverse reproductive effects. Percutaneous pharmacokinetic studies showed low skin penetration, with lowest values measured in vitro in rats and human skin. Overexposure of humans produces typical sensory irritant effects on the eye, skin and respiratory tract. Some reports have described an asthmatic-like reaction by overexposure to GA vapor. In most cases this resembles reactive airways dysfunction syndrome, and the role of immune mechanisms is uncertain. Local mucosal effects may occur if medical instruments or endoscopes are not adequately decontaminated. Protection of individuals from the potential adverse effects of GA exposure requires that there be adequate protection of the skin, eyes and respiratory tract. The airborne concentration of GA vapor should be kept below the recommended safe exposure level (e.g. the threshold limit value) by the use of engineering controls. Those who work with GA should, through a training program, be aware of the properties of GA, its potential adverse effects, how to handle the material safely and how to deal with accidental situations involving GA. If effects develop in exposed workers, the reasons should be determined immediately and corrective methods initiated. (c) 2001 John Wiley & Sons, Ltd.

Administration, Inhalation↗

The effect of particle wear debris on NFkappaB activation and pro-inflammatory cytokine release in differentiated THP-1 cells.

Orthopedic wear debris has been thought to be an important factor associated with osteolysis and loosening of total joint arthroplasties. Previous in vitro studies have reported that particles of wear debris induce the release of pro-inflammatory cytokines and other inflammatory mediators from macrophages and other cells. Several recent investigations, however, have suggested that the wear particles themselves may not be primarily responsible for the inflammatory cellular responses, but that the observed cytokine release in vitro may be caused by endotoxin adsorbed to commercially available particle preparations. The intracellular pathways involved in macrophage signal transduction also are poorly understood. The purposes of this study are to use isolated orthopedic wear debris particles to evaluate pro-inflammatory cytokine release and nuclear factor kappa B (NFkappaB) activation from macrophages. Cells from human monocyte/macrophage cell line (THP-1) were differentiated and incubated with particles of debris that had been isolated from a failed human total hip arthroplasty. The titanium-alloy particles did not evoke release of TNF-alpha or IL-1beta whereas lipopolysaccharide (LPS) or LPS-treated debris particles induced both TNF-alpha and IL-1beta. LPS-treated particles, but not particles alone, stimulated NFkappaB activation. Our results suggest that at the concentrations tested in this study, endotoxin-free wear debris particles may not themselves initiate inflammatory cellular responses in differentiated THP-1 cells. It is unclear whether adsorbed endotoxin is clinically associated with osteolysis and/or loosening in total joint arthroplasties, but several factors, including adsorbed endotoxin, need to be investigated to explore the cellular responses responsible for osteolysis and/or loosening.

Arthroplasty, Replacement↗