Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Environmental monitoring”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Versatile mobile lidar system for environmental monitoring.

A mobile lidar (light detection and ranging) system for environmental monitoring is described. The optical and electronic systems are housed in a truck with a retractable rooftop transmission and receiving mirror, connected to a 40-cm-diameter vertically looking telescope. Two injection-seeded Nd:YAG lasers are employed in connection with an optical parametric oscillator-optical parametric amplification transmitter, allowing deep-UV to mid-IR wavelengths to be generated. Fast switching that employs piezoelectric drivers allows multiwavelength differential absorption lidar for simultaneous measurements of several spectrally overlapping atmospheric species. The system can also be used in an imaging multispectral laser-induced fluorescence mode on solid targets. Advanced LabVIEW computer control and multivariate data processing render the system versatile for a multitude of measuring tasks. We illustrate the monitoring of industrial atmospheric mercury and hydrocarbon emissions, volcanic sulfur dioxide plume mapping, fluorescence lidar probing of seawater, and multispectral fluorescence imaging of the facades of a historical monument.

Journal Article↗

Environmental monitoring of chromium in air, soil, and water.

Historical uses of chromium have resulted in its widespread release into the environment. In recent years, a significant amount of research has evaluated the impact of chromium on human health and the environment. Additionally, numerous analytical methods have been developed to identify and quantitate chromium in environmental media in response to various state and federal mandates such as CERCLA, RCRA, CWA, CAA, and SWDA. Due to the significant toxicity differences between trivalent [Cr(III)] and hexavalent [Cr(VI)] chromium, it is essential that chromium be quantified in these two distinct valence states to assess the potential risks to exposure to each in environmental media. Speciation is equally important because of their marked differences in environmental behavior. As the knowledge of risks associated with each valence state has grown and regulatory requirements have evolved, methods to accurately quantitate these species at ever-decreasing concentrations within environmental media have also evolved. This paper addresses the challenges of chromium species quantitation and some of the most relevant current methods used for environmental monitoring, including ASTM Method D5281 for air, SW-846 Methods 3060A, 7196A and 7199 for soils, sediments, and waste, and U.S. EPA Method 218.6 for water.

Air Pollutants↗

The use of biomarkers in environmental monitoring programmes.

The monitoring of biological effects has recently become an integral component of environmental monitoring programmes as a supplement to the commonly used contaminant monitoring. Over the years, many biomarkers have been developed that are claimed to be efficient at providing an early warning of deleterious effects on biological systems and for estimating biological effects due to contaminants. Although biomarkers are potentially useful, they have a number of important limitations. In this paper, we examine some of the key assumptions behind the theory and practice of use of biomarkers, and propose a scheme, which may facilitate decisions by environmental managers as to how and when to use biomarkers in their monitoring programmes.

Animals↗

Continuous determination of fine particulate matter mass in the Salt Lake City Environmental Monitoring project: a comparison of real-time and conventional TEOM monitor results.

Fine particulate matter (PM2.5) mass was determined on a continuous basis at the Salt Lake City Environmental Protection Agency Environmental Monitoring for Public Awareness and Community Tracking monitoring site in Salt Lake City, UT, using three different monitoring techniques. Hourly averaged PM2.5 mass data were collected during two sampling periods (summer 2000 and winter 2002) using a real-time total ambient mass sampler (RAMS), sample equilibration system (SES)-tapered element oscillating microbalance (TEOM), and conventional TEOM monitor. This paper compares the results obtained from the various monitoring systems, which differ in their treatment of semivolatile material (SVM; particle-bound water, semivolatile ammonium nitrate, and semivolatile organic compounds). PM2.5 mass results obtained by the RAMS were consistently higher than those obtained by the SES-TEOM and conventional TEOM monitors because of the RAMS ability to measure semivolatile ammonium nitrate and semivolatile organic material but not particle-bound water. The SES-TEOM monitoring system was able to account for an average of 28% of the SVM, whereas the conventional TEOM monitor loses essentially all of the SVM from the single filter during sampling. Occasional mass readings by the various TEOM monitors that are higher than RAMS results may reflect particle-bound water, which, under some conditions, is measured by the TEOM but not the RAMS.

Air Pollutants↗

Environmental monitoring and assessment of a Great River ecosystem: the Upper Missouri River pilot.

Most Great River ecosystems (GREs) are extensively modified and are not receiving adequate protection to prevent further habitat degradation and loss of biotic integrity. In the United States, ecological monitoring and assessment of GREs has lagged behind streams and estuaries, and the management of GREs is hampered by the lack of unbiased data at appropriate spatial scales. Properties of GREs that make them challenging to monitor and assess include difficult sample logistics and high habitat diversity. The U.S. Environmental Protection Agency's Environmental Monitoring and Assessment Program (EMAP) has developed a comprehensive, regional-scale, survey-based monitoring approach to assessment of streams and estuaries, but has not yet conducted research on applying these tools to GRE monitoring. In this paper we present an overview of an EMAP research project on the Upper Missouri River (UMR). We summarize the assessment objectives for the study, the design for selecting sample locations, the indicators measured at these sites and the tools used to analyze data. We present an example of the type of statements that can be made with EMAP monitoring data. With modification, the set of methodologies developed by EMAP may be well suited for assessment of GREs in general.

Conservation of Natural Resources↗

Volunteer environmental monitoring and the role of the universities: the case of Citizens' Environment Watch.

Universities can provide a stable home for launching collaborative community research projects. Citizens' Environment Watch (CEW), an environmental monitoring initiative based at the University of Toronto, has made significant contributions to environmental education and stewardship in Ontario, Canada. Following dramatic cuts in provincial monitoring programs, citizens and youth have used chemical parameters and biological indicators to gauge water and air quality, and to identify areas requiring remediation and pollution prevention efforts. The relationship of Citizens' Environment Watch to government agencies, funders and other grassroots environmental groups has evolved over the past 5 years as CEW attempts to remain effective without taking on the investigative and enforcement roles to support the regulatory enforcement that has been largely abandoned by government. We explore the challenges inherent in developing and maintaining a volunteer organization that carries out rigorous and useful scientific work and we outline the ability of a university to help overcome these critical challenges. Finally, we present lessons learned for the benefit of other citizen and youth monitoring projects.

Canada↗

Toxaphene in standard solutions and cleaned biota extracts--results of the first QUASIMEME interlaboratory studies. Quality Assurance of Information for Marine Environmental Monitoring in Europe.

Two interlaboratory studies on individual toxaphene congeners have been organised by the project Quality Assurance of Information for Marine Environmental Monitoring in Europe (QUASIMEME). Fifteen laboratories analysed two standard solutions in the first study and 13 laboratories analysed a standard solution and two cleaned biota extracts in the second study. The coefficients of variation obtained for the standard solutions were 6-21% and for the cleaned extracts 16-39%. Although the results were comparable to those of other studies, further improvement in the level of agreement between the participating laboratories was considered possible.

Animals↗

Bioseparation and bioanalytical techniques in environmental monitoring.

The growing use of antibody-based separation methods has paralleled the expansion of immunochemical detection methods in moving beyond the clinical diagnostic field to applications in environmental monitoring. In recent years high-performance immunoaffinity chromatography, which began as a separation technique in biochemical and clinical research, has been adapted for separating and quantifying environmental pollutants. Bioaffinity offers a selective biological basis for separation that can be incorporated into a modular analytical process for more efficient environmental analysis. The use of immunoaffinity chromatography for separation complements the use of immunoassay for detection. A widely used immunochemical detection method for environmental analyses is enzyme immunoassay. The objective of this paper is to review the status of bioaffinity-based analytical procedures for environmental applications and human exposure assessment studies. Environmental methods based on bioaffinity range from mature immunoassays to emerging techniques such as immunosensors and immunoaffinity chromatography procedures for small molecules.

Biosensing Techniques↗

[Capacitive sensor for environmental monitoring based on thin films of molecularly imprinted polymers. Computer modeling for optimization of the composition of synthetic analogs of bioreceptors].

A capacitive sensor for environmental monitoring based on thin films of desmetryn-selective molecularly imprinted polymer (MIP) was developed. The method of modification of gold electrodes with the thin film of herbicide-selective MIP using the grafting polymerization approach was developed. The method of computational modeling was used to optimize the composition of desmetryn-selective MIPs. It was shown that 2-acrylamido-2-methyl-1-propan-sulfonic acid is the optimal functional monomer for desmetryn. Formation of synthetic binding sites in MIPs was demonstrated to be determined by the binding energy between the template and functional monomers as well as the number of functional groups taking part in the recognition of the template molecule. Electrochemical processes occurring at the MIP-modified electrode were analyzed. The detection limit for desmetryn comprised 100 nM. High selectivity of the capacitive sensor towards structural analogues of desmetryn as well as high operational and storage stabilities was demonstrated.

Biomimetic Materials↗

Environmental monitoring by gene expression biomarkers in Barbus graellsii: laboratory and field studies.

Barbel (Barbus graellsii) is a freshwater fish used as a sentinel species in environmental monitoring programmes and ecotoxicological studies in northern Spain, particularly in the Ebro River basin, the largest freshwater resource in Spain. We developed specific primers for the quantification of CYP1A and metallothionein (MT)-1 and -2 gene expression by QRT-PCR in barbel in order to assess their suitability in biological effect monitoring of dioxin-like compounds and metals. All three genes responded as expected in laboratory tests, using model inducers. Hepatic CYP1A mRNA levels showed a twofold induction in fish injected intraperitoneally with beta-naphthoflavone, whereas MT-1 and MT-2 gene expression was strongly induced by cadmium (15- and 13-fold, respectively) and mercury (five- and eightfold). Barbel populations from different sites on the Ebro River basin showed a good correlation between the historical records of organochlorine pollution, CYP1A expression levels and EROD activity. Nevertheless, although metallothionein protein levels in the liver of wild fish correlated with hepatic levels of mercury, MT-1 and MT-2 gene expression did not correlate with the mercury content or with the concentration of metals in sediments from the sites inhabited by the fish. These results demonstrate the utility of barbel CYP1A-mRNA expression, but not that of MT-1 or MT-2, as a biomarker in field studies. The tools and protocols developed here are likely to apply to other species of the genus Barbus, with some 700 species distributed throughout most of the Old World.

Amino Acid Sequence↗

Biosensors in flow-injection systems for biomedical analysis, process and environmental monitoring.

This paper presents the construction of various biosensors using thin-film layers incorporated in flow injection devices, providing automated systems for biomedical analysis, process and environmental monitoring. A urease sensor has been developed in conjunction with a flow injection system for the automatic determination of urea. Use of the spraying immobilization technique gives rise to a response time of a few seconds, which allows sample throughputs up to 200 h-1. With a penicillin biosensor adapted in an appropriate cell detection, on-line measurements of penicillin V in the fermentation broth are achieved during the whole fermentation process; the results are compared with the HPLC method. Linearity, sensitivity and reproducibility of the biosensor are studied with regards to sample dilution in a stirred flow detection cell to provide optimal operating conditions. Measurements without any change in parameters are obtained during the whole fermentation process. Acetylcholinesterase sensors have been used in batch systems for the determination of pesticides, but they require large amounts of substrate. When those enzyme sensors are combined with flow injection systems, only small volumes (100 microliters) of substrate are injected into the carrier stream and an automated system can be obtained for continuous control of water quality.

Biosensing Techniques↗

Biological and environmental monitoring of hospital personnel exposed to antineoplastic agents: a review of analytical methods.

In order to assess occupational exposure of hospital personnel involved in the preparation and administration of antineoplastic drugs, biological and environmental monitoring are essential to identify the main exposure routes and to quantify potential health risks. If workplace contamination cannot be completely avoided, it is of utmost importance to reduce exposure to the lowest possible levels. To this aim, not only do education and training of the exposed subjects play an important role, but accurate standardized sampling techniques and analytical methods are also required. A critical overview of the most significant methods available in the literature is presented and their value is discussed, especially with respect to their sensitivity and specificity. In addition, attention is given to validation procedures and, consequently, to their reliability. The results from the most important surveys carried out at hospital departments are also discussed, with a view to improving both monitoring strategies and moreover working conditions.

Antineoplastic Agents↗

Enzyme inhibition-based biosensors for food safety and environmental monitoring.

Analytical technology based on sensors is an extremely broad field which impacts on many major industrial sectors such as the pharmaceutical, healthcare, food, and agriculture industries as well as environmental monitoring. This review will highlight the research carried out during the last 5 years on biosensors that are based on enzyme inhibition for determination of pollutants and toxic compounds in a wide range of samples. Here the different enzymes implicated in the inhibition, different transducers forming the sensing devices, and the different contaminants analyzed are considered. The general application of the various biosensors developed, with emphasis on food and environmental applications, is reviewed as well as the general approaches that have been used for enzyme immobilization, the enzyme catalysis, and the inhibition mechanism.

Biosensing Techniques↗

On-line and in situ biosensors for monitoring environmental pollution.

Efficient tools for on-line and in situ monitoring of environmental pollutants are required to provide early warning systems. In addition, such tools can contribute important information on the progress of various remediation treatments. One of the recently developed monitoring technologies involves the use of whole-cell biosensors. Such biosensors could be constructed to detect general toxicity or specific toxicity caused by one or more pollutants. Currently, a large spectrum of microbial biosensors have been developed that enable the monitoring of pollutants by measuring light, fluorescence, color or electric current. Electrochemical monitoring is of special interest for in situ measurements as it can be performed using simple, compact and mobile equipment and is easily adaptable for on-line measurements. Here we survey the potential application of electrochemical biosensors in monitoring of general toxicity as well as hydrocarbons and heavy metals.

Bacteria↗

Integrated environmental monitoring and simulation system for use as a management decision support tool in urban areas.

Leachates are generated as a result of water or other liquid passing through waste at a landfill site. These contaminated liquids originate from a number of sources, including the water produced during the decomposition of the waste as well as rain-fall which penetrates the waste and dissolves the material with which it comes into contact. The penetration of the rain-water depends on the nature of the landfill (e.g. surface characteristics, type and quantity of vegetation, gradient of layers, etc). The uncontrolled infiltration of leachate into the vadose (unsaturated) zone and finally into the saturated zone (groundwater) is considered to be the most serious environmental impact of a landfill. In the present paper the water flow and the pollutant transport characteristics of the Ano Liosia Landfill site in Athens (Greece) were simulated by creating a model of groundwater flows and contaminant transport. A methodology for the model is presented. The model was then integrated into the Ecosim system which is a prototype funded by the EU, (Directorate General XIII: Telematics and Environment). This is an integrated environmental monitoring and modeling system, which supports the management of environmental planning in urban areas.

Cities↗

Environmental monitoring and decision-making.

This paper combines insights from public administration and statistics to discuss the place of water quality monitoring in the decision making process. It uses measured data obtained from the monitoring of the River Elbe in the Federal Republic of Germany to illustrate the statistical argument. It is further based on my experience as a board member of a Water Authority and as a governor of the Municipality of Delft. The literature is overviewed by a quick scan on the Internet and by using insights obtained from the Global Environmental Monitoring Network, GEMS.

Decision Making↗

Tools for evaluation of impact associated with MSW incineration: LCA and integrated environmental monitoring system.

The identification of significant pollutants emitted from the contamination source is the first step in evaluating the impact associated with anthropic activity. Municipal solid waste (MSW) incinerators are still generally perceived as great pollutant sources, in particular due to their gaseous emissions from the stack, which constitute the major effluent from the plant. In this work a life cycle assessment and an integrated environmental monitoring system were applied together, in order to obtain complete information about the incineration process and its environmental impact. The former is a proven methodology, but its application to waste management systems constitutes a relatively new field of application with a great developmental potential. The contribution of the incineration process to the different environmental impact categories was investigated, finding many avoided impacts due to energy recovery. The latter is an innovative approach that allows a remarkable understanding of impact due to a contamination source; interesting correlations were found between heavy metals both in gas emissions and in natural matrices in the surroundings.

Air Pollutants↗