Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Electric Conductivity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Electrical conducting and magnetic properties of (ethylenedithiotetrathiafulvalenothioquinone-1,3-diselenolemethide)2.FeBr4 (GaBr4) crystals with two different interlayer arrangements of donor molecules.

Two donor molecules newly synthesized, dimethylthio- and ethylenedithio-tetrathiafulvalenothioquinone-1,3-diselenolemethides (1 and 2), were used to prepare their charge-transfer (CT) salts with a magnetic FeBr(4)(-) counteranion. For 1, a low electrical conducting 1:1 salt (1.FeBr(4)) was obtained, in which molecules of 1 are tightly dimerized in a one-dimensional (1D) stacking column. On the other hand, 2 gave a 2:1 salt (2(2).FeBr(4)) as two different kinds of plate crystals (I and II). Both I and II possess similar stacking structures of molecules of 2 in each 1D column with a half-cut pipelike structure along the c axis. However, for I, the stacking columns are aligned in the same direction along the a and b axes, while for II they are in the same direction along the a axis, but in the reverse direction along the b axis, resulting in the difference in the relative arrangement of molecules of 2 and FeBr(4)(-) ions between the two crystals. The room-temperature electrical conductivities of the single crystals of I and II were 13.6 and 12.7 S cm(-)(1), respectively. The electrical conducting behavior in I was metallic above 170 K but changed to be semiconducting with a very small activation energy of 7.0 meV in the temperature range 4-170 K. In contrast, II showed the semiconducting behavior in the whole temperature range 77-285 K. The corresponding nonmagnetic GaBr(4)(-) salts with almost the same crystal structure as I and II showed definitively different electrical conducting properties in the metal to semiconductor transition temperature in I as well as in the magnitude of activation energy in the semiconducting region of I and II. The interaction between the d spins of FeBr(4)(-) ions was weak and antiferromagnetic in both I and II, but the magnitude of the spin interaction was unexpectedly larger compared with that in the FeBr(4)(-) salt of the corresponding sulfur derivative of 2 with closer contact between the neighboring FeBr(4)(-) ions. These electrical conducting and magnetic results suggest a significant interaction between the conducting pi electrons and the d spins of FeBr(4)(-) ions located near the columns or layers.

Journal Article↗

Magnitude and modulation of pancreatic beta-cell gap junction electrical conductance in situ.

The parallel gap junction electrical conductance between a beta-cell and its nearest neighbors was measured by using an intracellular microelectrode to clamp the voltage of a beta-cell within a bursting islet of Langerhans. The holding current records consisted of bursts of inward current due to the synchronized oscillations in membrane potential of the surrounding cells. The membrane potential record of the impaled cell, obtained in current clamp mode, was used to estimate the behavior of the surrounding cells during voltage clamp, and the coupling conductance was calculated by dividing the magnitude of the current bursts by that of the voltage bursts. The histogram of coupling conductance magnitude from 26 cells was bimodal with peaks at 2.5 and 3.5 nS, indicating heterogeneity in extent of electrical communication within the islet of Langerhans. Gap junction conductance reversibly decreased when the temperature was lowered from 37 to 30 degrees C and when the extracellular calcium concentration was raised from 2.56 to 7.56 mM. The coupling conductance decreased slightly during the active phase of the burst. Activation of adenylate cyclase with forskolin (10 microM) resulted in an increase in cell-to-cell electrical coupling. We conclude that beta-cell gap junction conductance can be measured in situ under near physiological conditions. Furthermore, the magnitude and physiological regulation of beta-cell gap junction conductance suggest that intercellular electrical communication plays an important role in the function of the endocrine pancreas.

Animals↗

Measurement of total body electrical conductivity: a new method for estimation of body composition.

A new method for the estimation of body composition in human subjects is described which entails the measurement of total body electrical conductivity. The method is based on the principle that the electrical conductivity of lean tissue is far greater than that of fat. Comparative studies in 19 adults of widely varying fatness have demonstrated excellent correlations between the total electrical conductivity of the subjects and both their total body water (r = 0.87) and total body potassium (r = 0.86). This noninvasive method, which is safe, simple, rapid, and convenient, should prove useful in the nutritional assessment of individuals and populations.

Adult↗

[The electric conductivity indices of the skeletal muscles in the dynamics of the posttraumatic period].

In order to determine the time of inflicting mechanical trauma, values of electric conduction of skeletal muscles were measured taking into consideration postmortem interval and temperature of an object tested. Electric conduction of traumatized and intact muscles was determined within 0, 6, 12, 24, 48 and 72 hr of posttraumatic period directly after death (the 1st series of observations) and in different postmortal periods. The results of investigations disclose presence of certain time-course changes in parameters of electric conductivity of skeletal muscles depending on time of posttraumatic period.

Animals↗

Calculation of ionization balance and electrical conductivity in nonideal aluminum plasma.

A practical approach has been implemented to calculate the ionization balance and electrical conductivity of warm dense aluminum plasma with the Coulomb coupling effect taken into account. The correction term for ionization potential is formulated with a number of basic dimensionless parameters that characterize nonideal plasma and incorporated with the fitted formulas of excess free energy given by Tanaka, Mitake, and Ichimaru [Phys. Rev. A 32, 1896 (1985)] and Chabrier and Potekhin [Phys. Rev. E 58, 4941 (1998)] to determine the ionization balance in an equilibrium state. The calculated degree of ionization of aluminum plasma exhibits a sudden increase near the solid density approximately 1 g/cm(3) at temperatures of a few eV, which effectively demonstrates the pressure-induced ionization. The electrical conductivity is evaluated in a partially ionized plasma regime based on a linear mixture rule that takes into account both the electron-ion and electron-neutral collisions and then the computed results are compared with available data from recent experiments. It is shown that the calculation well reproduces the overall trend of measured electrical conductivity of nonideal aluminum plasma accounting for the metal-insulator transition.

Journal Article↗

The Electric Conductivity of Dilute Suspensions of Charged Porous Spheres

The effective electric conductivity of a dilute suspension of polyelectrolyte molecules or charged flocs in an electrolyte solution is analytically studied. The model used for the particles is a porous sphere in which the density of hydrodynamic frictional segments, and therefore also that of the fixed charges, is constant. The equations which govern the electrochemical potential distributions of ionic species and the fluid flow field inside and outside a porous particle migrating in an unbounded solution are linearized assuming that the system is only slightly distorted from equilibrium. Using a perturbation method, these linearized equations are solved for a porous sphere in a uniform applied electric field with the density of the fixed charges as the small perturbation parameter. An analytical expression for the effective conductivity of a dilute suspension of identical charged porous spheres is obtained from the average electric current density calculated using the solution of electrochemical potential distributions of the ions. The result demonstrates that the presence of the fixed charges in the porous particles can lead to an augmented or a diminished electric conductivity of the suspension relative to that of a corresponding suspension of uncharged porous particles, depending on the characteristics of the electrolyte solution and the suspending particles. When the anionic and cationic diffusion coefficients of a symmetric electrolyte are the same, the correction for the effect of the fixed charges of the particles on the electric conductivity of the suspension is proportional to the square of the fixed charge density. Copyright 1997Academic Press

Journal Article↗

Electrical conductivity of pH-responsive hydrogels.

The electrical conductivity of pH-responsive hydrogels based on cross-linked poly(2-hydroxyethyl methacrylate-co-dimethylaminoethyl methacrylate) copolymers has been studied as a function of pH over the range 5-10, for copolymers containing up to 20 mol% of the amine-containing comonomer. The conductivities of membranes equilibrated in buffered potassium chloride solutions were determined by measuring the electrical resistance of a membrane mounted between the chambers of a modified side-by-side diffusion cell. The conductivity, expressed as a fraction of the conductivity of the buffer in which the gels were equilibrated, ranged from 1% for the gels in the collapsed state to 70% for the most highly swollen gels. The observed results are qualitatively consistent with a proposed model in which the ion concentrations in the fluid phase of the gel are described by Donnan partitioning, and the ion mobilities by the free-volume theory of Yasuda. The results suggest that conductivity measurements may provide an alternative to diffusive transport studies for characterizing moderately swollen hydrogel membranes.

Cross-Linking Reagents↗

Total body electrical conductivity measurements: an evaluation of current instrumentation for infants.

Quantitation of the body's fat and learn masses is an important component of nutritional assessment. Such measurements, however, are difficult to conduct routinely in infants due to the numerous limitations of traditional methods. The application of total body electrical conductivity measurements for quantitating fat-free mass (FFM) overcomes many of these limitations. The instruments required to perform these measurements in pediatric patients (HP-2) have recently become commercially available, but their measurement performance has not been evaluated. In these studies, we compared the precision, day-to-day variability, and magnetic field profile of three HP-2 instruments. We also derived a new calibration equation that relates the FFM to the total body electrical conductivity measurement in piglets, and compared it with an equation (provided currently by the manufacturer) derived on a prototype instrument. The performance of the instruments was generally similar, although a significant difference in the magnetic field of one instrument was identified. The coefficient of variation of inanimate phantom measurements varied from +/- 0.2 to +/- 0.5%, and the day-to-day variability was generally similar. Such measurement error is significant (+/- 0.035 to +/- 0.078 kg FFM) for small subjects. The new calibration equation was similar to the original equation; therefore, all the data were pooled to generate a new equation that is linear at least to 10 kg. Thus, the HP-2 total body electrical conductivity instruments, which can be safely and easily used to measure FFM and fat in infants through 1 y of age, proved to be reliable and precise, and results obtained from different instruments can be confidently compared.

Adipose Tissue↗

Accuracy and reliability of total body electrical conductivity (TOBEC) for determining body composition of rats in experimental studies.

Total body electrical conductivity (TOBEC) has been promoted as a noninvasive method to estimate body composition in small mammals. Validation of this method has primarily been under normative conditions and has generally been inadequate. This article reports on the reliability and accuracy of TOBEC methodology to assess gradual, physiologically induced changes in body composition in rats under different experimental conditions. Reliability of the index of electrical conductivity (EM number) was assessed by analyzing components of variance. Accuracy was assessed by comparing EM number to actual lean body mass (LBM, from carcass analysis), across different experimental conditions, within a particular experimental condition, and over time for a given set of animals. Reliable measurements were obtained by strictly adhering to a standard protocol. TOBEC was inaccurate across experimental conditions, within experimental conditions, and within a single experimental condition during the course of an experiment. This inaccuracy apparently stemmed from the lack of a direct relationship between EM number and LBM; EM number was more strongly correlated with body weight than with LBM. At the present time, TOBEC cannot be used in place of carcass analysis to accurately predict the body composition of rats during or following the administration of a variety of experimental conditions.

Adipose Tissue↗

The influence of the splanchnic nerves on the external secretion, blood flow and electrical conductance of the cat pancreas.

1. Electrical stimulation of the cut peripheral end of the splanchnic nerves results in a biphasic change in electrical conductance measured across the tail of the pancreas. A phase of decreased conductance is followed by a more prolonged phase of increased conductance.2. Simultaneous measurements of pancreatic blood flow indicate that the phase of decreased conductance occurs as a result of vasoconstriction, whilst the phase of increased conductance is due to vasodilatation.3. The initial phase of decreased conductance and vasoconstriction is abolished by alpha-receptor blocking agents such as phenoxybenzamine and the phase of increased conductance blocked by beta-receptor blocking agents such as pronethalol.4. Short periods of electrical stimulation applied to the splanchnic nerves result in a secretion of amylase and a reduction in the volume rate of secretion.5. When the vasoconstrictor response was abolished by phenoxybenzamine, nerve stimulation still reduced the rate of secretion, suggesting that the inhibitory effect is in part due to a direct action of the secretory cells.6. After bretylium tosylate, splanchnic nerve stimulation no longer produced vasomotor changes in the pancreas and the inhibitory effect on the volume response was converted to one of augmentation, but the secretion of enzymes was unaffected.7. The secretion of amylase on splanchnic stimulation was abolished by intravenous injection of atropine, suggesting that a cholinergic mechanism is involved.8. Noradrenaline did not mobilize pancreatic enzymes.

Journal Article↗

Electrical conductivity of polyelectrolyte solutions in the presence of added salt: The role of the solvent quality factor in light of a scaling approach.

The effects of added salt on the electrical conductivity behavior of a polyelectrolyte solution are described in light of the scaling approach recently proposed by Dobrynin and Rubinstein [Macromolecules 28, 1859 (1995); 32, 915 (1999)], taking into account the influence of the solvent quality factor. The coupling between the conformation of the chain and the local charge distribution, giving rise to different conductometric behaviors, has been investigated under different conditions, in a wide concentration range of added salt. The polyion equivalent conductances lambda(p) have been evaluated in different concentration regimes for a hydrophilic polyion in good solvent condition and compared with the experimental values obtained from electrical conductivity measurements. The agreement is rather good in the wide range of concentration of the added salt investigated. In the case of poor solvent conditions, we find the appropriate expressions for the electrical conductivity when the polyion chain consists into collapsed beads alternating with stretched segments in the framework of the necklace globule model.

Electric Conductivity↗

Influence of temperature on the electrical conductivity of leachate from municipal solid waste.

A bioreactor landfill is designed to manage municipal solid waste, through accelerated waste biodegradation, and stabilisation of the process by means of the controlled addition of liquid, i.e. leachate recirculation. The measurement of electrical resistivity by Electrical Resistivity Tomography (ERT) allows to monitor water content present in the bioreactors. Variations in electrical resistivity are linked to variations in moisture content and temperature. In order to overcome this ambiguity, two laboratory experiments were carried out to establish a relationship between temperature and electrical conductivity: the first set of measurements was made for leachate alone, whereas the second set was made with two different granular media saturated with leachate. Both experiments confirm a well known increase in conductivity of about 2% degrees C(-1). However, higher suspended matter concentrations lead to a lower dependence of electrical conductivity on temperature. Furthermore, for various porous media saturated with an identical leachate, the higher the specific surface of the granular matrix, the lower the effective bulk electrical conductivity. These observations show that a correct understanding of the electrical properties of liquids requires the nature and (in particular) the size of the electrical charge carriers to be taken into account.

Bioreactors↗

The effect of illumination on the electrical conductance of rhodopsin solutions.

An apparatus was constructed in order to record continuously and simultaneously changes in extinction and electrical conductance of rhodopsin solutions. With this apparatus, changes in electrical conductance on exposing rhodopsin to light were investigated. On illumination solutions of rhodopsin revealed a conductance change so long as they preserved their photosensitivity. The conductance change begins almost immediately upon illumination and is almost proportional to the amount of rhodopsin decomposed, continuing until rhodopsin is converted to indicator yellow. Near pH 7 the conductance is apt to increase slightly, while it decreases considerably outside the range of pH 6-9, being accompanied by a pH change towards neutrality. The conductance change is regarded as an essential property of rhodopsin, because it occurs in aqueous suspension as well as in digitonin solution; it may be caused by hydrogen or hydroxyl ions and some other conductive substances. It is also noteworthy that the petroleum ether-soluble component of the rod outer segments-presumably the lipide-tends to increase the conductance change. In suspensions of rod outer segments and retinal homogenates, the conductance increases on illumination irrespective of pH: this may be due to secondary reactions following the photic reaction of rhodopsin. We shall discuss the significance of the conductance change in relation to the initiation of visual excitation.

Electric Conductivity↗

Detection of clinical mastitis by changes in electrical conductivity of foremilk before visible changes in milk.

Mastitis was induced by the direct infusion of Staphylococcus aureus or Streptococcus uberis into the mammary gland of lactating cows. Changes in electrical conductivity of foremilk indicated the establishment of bacteria, increased SCC, increased clotting of milk, and, hence, disease, in advance of visible changes in the milk that could be diagnosed by a herdsperson. Clinical mastitis was detectable by changes in electrical conductivity of foremilk, 90% of cases were detectable when clots first appeared in foremilk, and 55% of cases were detectable up to 2 milkings prior to the appearance of clots. All subclinical infections from Staph. aureus were detected, but subclinical infections from Strep. uberis were not detected. The results suggested that clinical mastitis caused by these two major pathogens could be detected earlier by measuring changes in electrical conductivity of milk than by waiting for a herdsperson to detect visible changes in milk. Earlier detection would permit earlier treatment. However, the handheld sensor used in this experiment is impractical for commercial application, and reliable automated sensors and decision-making algorithms are required.

Animals↗

[A study of specific electrical conductivity of water by the action of constant magnetic field, electromagnetic field, and low-frequency mechanical vibrations].

The effect of a constant magnetic field, an electromagnetic field, and low-frequency mechanical vibrations on specific electrical conductivity of distilled water was studied. Newly formed (fresh), three-day- and six-day-old distilled water was used. The exposure of distilled water to a constant magnetic field (2.5 mT), electromagnetic field (2.5 mT and 1-100 Hz), low-intensity mechanical vibrations (1-100 Hz) with an intensity of 30 Db led to a reduction of its specific electrical conductivity. It was found that, as water aged, the effect of these factors on the specific electrical conductivity decreased.

Electric Conductivity↗

[Effect of various factors on the electric conductivity of mixed milk].

The authors evaluated the method of the determination of the electric conductivity of purchased milk for the estimation of the hygienic aspects of milk quality and for mass diagnosis of the inflammatory diseases of dairy cow mammary glands. The variability coefficient of duplicates varied from 1.37 to 3.09%. The study of the dependence of milk conductivity measurement on milk temperature revealed a statistically highly significant positive correlation between the values of these two factors. In the temperature range from 30 degrees C to 35 degrees C the coefficients of correlation ranged from 0.951 to 0.996. Furthermore, interference caused by milk acidity was examined during a five-day incubation of samples at 25 degrees C. A statistically significant difference was observed from the third hour of incubation (P less than 0.05) and a statistically highly significant difference from the fourth hour of incubation (P less than 0.01). The evaluation of the diagnostic value of the method of the measurement of electric conductivity in purchased milk revealed a positive correlation to the content of chloride ions (r = 0.69) and to the number of the cellular elements of milk (r = 0.33).

Animals↗

[Influence of some factors on the electric conductivity of mixed milk].

The authors evaluated the method of the determination of the electric conductivity of purchased milk for the estimation of the hygienic aspects of mlik quality and for mass diagnosis of the inflammatory diseases of dairy cow mammary glands. The variability coefficient of duplicates varied from 1.37 to 3.09%. The study of the dependence of milk conductivity measurement on milk temperature revealed a statistically highly significant positive correlation between the values of these two factors. In the temperature range from 30 degrees C to 35 degrees C the coefficients of correlation ranged from 0.951 to 0.996. Furthermore, interference caused by milk acidity was examined during a five-day incubation of samples at 25 degrees C. A statistically significant difference was observed from the third hour of incubation (P less than 0.05) and a statistically highly significant difference from the fourth hour of incubation (P less than 0.01). the evaluation of the diagnostic value of the method of the measurement of electric conductivity in purchased milk revealed a positive correlation to the content of chloride ions (r = 0.69) and to the number of the cellular elements of milk (r = 0.33).

Acids↗

Electrical conductivity of nonideal carbon and zinc plasmas: experimental and theoretical results.

Electrical conductivities of nonideal carbon and zinc plasmas have been measured in this paper. The plasma is produced by vaporizing a wire placed in a glass capillary within some hundred nanoseconds. In the case of carbon, vaporization occurs with good reproducibility when utilizing a preheating system. The particle density is in the range of n=(1-10) x 10(21) cm(-3). The plasma temperature, which is obtained by fitting a Planck function to the measured spectrum, is between 7-15 kK. Plasma radius and behavior of the plasma expansion were studied with a streak, a framing or an intensified charge coupled device camera. We compare the measured electrical conductivities with theoretical results, which were obtained solving quantum kinetic equations for the nonideal partially ionized plasmas. In this approach, the transport cross sections are calculated on the level of a T-matrix approximation using effective potentials. The plasma composition is determined from a system of coupled mass action laws with nonideality corrections.

Journal Article↗