Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Copying Processes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Variations in the emissions of volatile organic compounds from the toner for a specific photocopier.

A laboratory thermal desorption apparatus was used to measure emissions from a number of nominally identical photocopier toners--manufactured to meet the specifications of one specific model copier--when these toners were heated to fuser temperature (180-200 degrees C). The objective was to assess how potential volatile organic compound (VOC) emissions from the toner for a given copier can vary, depending upon the production run and the supplier. Tests were performed on a series of toner (and associated raw polymer feedstock) samples obtained directly from a toner manufacturer, representing two production runs using a nonvented extrusion process, and on toner cartridges purchased from two local retailers, representing three different production lots (histories unknown). The results showed that the retailer toners consistently had up to 350% higher emissions of some major compounds (expressed as microgram of compound emitted/g of toner), and up to 100% lower emissions of others, relative to the manufacturer toners (p < or = 0.01). The manufacturer toners from one production run had emissions of certain compounds, and of total VOCs, that were modestly higher (13-18%) than those from the other run (p < or = 0.01). The emission differences between the retailer and manufacturer toners are probably due to differences in the manufacturing processes and/or feedstocks used to produce the toners from these different sources.

Air Pollution, Indoor↗

A practical technique for the fabrication of transparent bite mark overlays.

A quick, inexpensive, and accurate technique for generating transparent overlays, using office photocopy machines, for use in bite mark case analysis is presented. The critical step in the fabrication process involves determination of the accuracy of the product produced by the photocopy machine. A reliable method for making such a determination is discussed.

Bites, Human↗

Copy-choice recombination mediated by DNA polymerase III holoenzyme from Escherichia coli.

Formation of deletions by recombination between short direct repeats is thought to involve either a break-join or a copy-choice process. The key step of the latter is slippage of the replication machinery between the repeats. We report that the main replicase of Escherichia coli, DNA polymerase III holoenzyme, slips between two direct repeats of 27 bp that flank an inverted repeat of approximately equal 300bp. Slippage was detected in vitro, on a single-stranded DNA template, in a primer extension assay. It requires the presence of a short (8 bp) G+C-rich sequence at the base of a hairpin that can form by annealing of the inverted repeats. It is stimulated by (i) high salt concentration, which might stabilize the hairpin, and (ii) two proteins that ensure the processivity of the DNA polymerase III holoenzyme: the single-stranded DNA binding protein and the beta subunit of the polymerase. Slippage is rather efficient under optimal reaction conditions because it can take place on >50% of template molecules. This observation supports the copy-choice model for recombination between short direct repeats.

Base Sequence↗

Fluorescence resonance energy transfer analysis of ribozyme kinetics reveals the mode of action of a facilitator oligonucleotide.

A defining characteristic of catalysts is the rate at which they can process multiple copies of substrate. In the case of synthetic hammerhead ribozymes that cleave an RNA sequence, binding of the ribozyme to the substrate and products is through base-paired duplexes. The kinetics of formation and dissociation of these duplexes can determine the turnover of the ribozyme. We have followed these processes in real time by using fluorescent labels that can interact through fluorescence resonance energy transfer (FRET). This approach has been used to identify the rate-limiting steps for a particular ribozyme and to reveal how turnover was improved by a facilitator oligonucleotide. It was found that dissociation of the ribozyme-substrate complex is faster than cleavage to products. Hence, to undergo cleavage, most substrate molecules must interact with a ribozyme more than once. In the presence of a facilitator oligonucleotide, the complex is stabilized so that cleavage is faster than dissociation. Under these circumstances, cleavage of the substrate becomes the most likely outcome following binding to the ribozyme.

Base Sequence↗

Selective transcription and post-transcriptional processing of the heteroplasmic mitochondrial orf156 copies in the nucleus-cytoplasm hybrids of wheat.

Transcript profile and post-transcriptional processing of the mitochondrial orf156 were compared among the nucleus-cytoplasm (NC) hybrids of tetraploid and hexaploid wheat and their parental lines. These NC hybrids, in which the plasmon from the maternal Aegilops squarrosa parent is combined with the nuclear genomes of the paternal parents, and their parental lines were previously shown to have heteroplasmic copies of the polycistronic transcriptional unit nad3-orf156 in different sub-stoichiometries. Despite the heteroplasmic conditions, only single transcript types were detected among reverse transcription-PCR products of the orf156 mRNA in the respective lines. In the NC hybrids only a major maternal copy was transcribed and edited, likewise in the parental lines only single major copies were transcribed and edited. RNA gel blot analysis using the orf156 probe showed that the NC hybrids had the transcripts similar to the parental lines but unlike the maternal line. Primer extension analysis further revealed the orf156 transcripts with different 5' termini, which most probably resulted from the alternative post-transcriptional cleavages of the precursor mRNA. These cleaved transcripts were polymorphic not only among the lines but also among four different tissues. The cleavages were highly selective and the paternal-type cleavages predominated in the NC hybrids, irrespective of the tissues studied. This seemingly neutral polymorphisms in wheat could make this system convenient for further analysis of mitochondrial gene expression in plants.

5' Flanking Region↗

Reproduction of radiologic images on plain paper.

Skyrocketing health care costs and pressures from managed care have combined to promote cost-cutting strategies in radiology and radiation oncology departments. A study was conducted to evaluate the use of a high-resolution laser printer for printing plain-paper images as substitutes for both original and duplicate radiologic film images. A variety of radiologic images were used to evaluate the image reproduction capabilities of the printer in terms of linearity, detail, and contrast. In many cases, printed images had a quality comparable to that of the original images. Six computed tomographic (CT) scans and six radiation therapy simulator radiographs were compared with printed reproductions by each of seven board-certified radiation oncologists, who rated the reproductions as acceptable for documentation, acceptable for diagnostic purposes (CT scans only), or unacceptable. Ninety-five percent of printed CT images and 90% of printed simulation images were rated acceptable for documentation. The quality of printed images of radiation therapy port films was not quantitatively measured but was improved by adjusting image contrast and brightness and using various image enhancement techniques. The use of printed images is less expensive than that of processed film and eliminates the environmental, time, storage, and delivery problems associated with film. Technologic advances in imaging, networking, and printing have made possible the inexpensive duplication of medical images.

Copying Processes↗

[Neonatal information system II: computer-adapted examination form for the newborn (author's transl)].

For the documentation of the neonatal status we use computer-adapted optic mark reader forms since 1972. All important symptoms and signs are scheduled on two sheets and are assigned by pencil marking. The forms can be read automatically and are suitable for data processing. A copy remains in the patients clinical file and can be used like a conventionally written status. The mark reader forms improved singificantly our knowledge about the newborn's status. The problems of introducing the new documentation into the hospital routine are reported.

Computers↗

Variable copy number DNA sequences in rice.

We have cloned two types of variable copy number DNA sequences from the rice embryo genome. One of these sequences, which was cloned in pRB301, was amplified about 50-fold during callus formation and diminished in copy number to the embryonic level during regeneration. The other clone, named pRB401, showed the reciprocal pattern. The copy numbers of both sequences were changed even in the early developmental stage and eliminated from nuclear DNA along with growth of the plant. Sequencing analysis of the pRB301 insert revealed some open reading frames and direct repeat structures, but corresponding sequences were not identified in the EMBL and LASL DNA databases. Sequencing of the nuclear genomic fragment cloned in pRB401 revealed the presence of the 3'rps12-rps7 region of rice chloroplast DNA. Our observations suggest that during callus formation (dedifferentiation), regeneration and the growth process the copy numbers of some DNA sequences are variable and that nuclear integrated chloroplast DNA acts as a variable copy number sequence in the rice genome. Based on data showing a common sequence in mitochondria and chloroplast DNA of maize (Stern and Lonsdale 1982) and that the rps12 gene of tobacco chloroplast DNA is a divided gene (Torazawa et al. 1986), it is suggested that the sequence on the inverted repeat structure of chloroplast DNA may have the character of a movable genetic element.

Base Sequence↗

An evaluation of line quality in photocopied signatures.

Qualified forensic document examiners from Canada, USA, Great Britain and Australia participated in this study. They were sent one photocopied signature, together with a set of original known standards to evaluate the line quality of the photocopied signature and compare these characteristics with the standards. They were asked to assess the photocopies for the presence of tremor, hesitation, pen lifts, patching, blunt initial or terminal strokes, and abrupt changes in direction. The authors compared the assessments with the corresponding original signatures. It was possible to determine which line quality characteristics were the most difficult to detect, which indicia of simulation were concealed and what anomalies were introduced by the photocopying process. Results indicated that line quality characteristics can be identified in average quality photocopies. Furthermore, accurate judgements can be made regarding similarities and differences in line quality when comparing a photocopied signature with original known standards. In a few instances, ink line morphology was problematic when striation patterns and ink gooping were misinterpreted as pen lifts, hesitation and patching on the photocopies.

Copying Processes↗

Manual and computer-aided space analysis: a comparative study.

Recently, computers have been used to measure key landmarks from photocopies of upper and lower study models to increase simplicity, accuracy, and informatics. This is a comparative study to evaluate the accuracy and reliability of computer-aided space analysis. Data were collected from a series of randomly selected study models. All subjects had Angle Class I molar relationships with minor malocclusions such as crowding, rotations, or diastemas. Two investigators independently measured teeth on models with a Vernier gauge that had sharpened caliper tips. Intraexaminer and interexaminer reliability was determined at 0.2 mm. All teeth, to and including the first molars, were measured. Two photocopies of each set of models were made on a photostat machine (Xerox, Japan) and were coded. A template with a ruler was used, to allow the investigator to compensate for any reduction or enlargement error during the photocopying process. The mesiodistal sizes were measured with a digitizer, and results were processed by using a dedicated computer program. Evaluations were done in a double-blind manner. The nonparametric Wilcoxon signed rank test for paired observations to compare median differences between measurements was used. Intraexaminer digitized measurements were almost identical and differed (p < 0.0001) for only one measurement. However, interexaminer manual and digitized measurements differed significantly (p < 0.001) for 20 of the 24 teeth. Nineteen of these digitized tooth measurements were smaller. The mean arch length measurements differed by 4.7 mm (p < 0.0001) in the maxilla and by 3.1 mm (p < 0.0001) in the mandible. The difference between the manual and digitized analyses may be due to the photocopying process. The inability to accurately measure a three-dimensional study cast that has been duplicated in two dimensions, convex structure of teeth, curve of Spee, tooth inclination, and tooth position may play a role. The computer-aided measuring system is reliable, but accurate mesiodistal measurements cannot be made from photocopies of dental models. Manual measurements that use a calibrated gauge produce the most accurate, reliable, and reproducible results.

Calibration↗

Maintaining confidentiality: health care's ongoing dilemma.

Confidentiality of patient information is an ethical obligation of health care professionals. The exercise of confidentiality is not a simple process; it is dynamic rather than static and must be upgraded with changes in technology. This article discusses some of the common issues that arise in maintaining confidentiality in the health care environment, including spoken and written breaches of confidentiality, use of the computer, confidentiality as an ethical rather than legal obligation, and the use of programs in health care institutions to maintain confidentiality.

Attitude of Health Personnel↗

Converting a large photographic negative collection to digital form.

Like many media production facilities in recent years, we at the University of Arkansas for Medical Sciences' Media Services have made the transition from silver and wet photographic processes to digital production methods. During that process we found that many of our products had to be transferred from traditional to digital form. One major asset we had was a portrait negative file that contained about 13,000 photographic negatives of nearly 6,000 individuals. These negatives were of individuals currently on staff or who had had their portrait taken while on staff in the past. The oldest of these negatives went back twenty years. About 65 percent of the collection consisted of 4 x 5 black and white negatives and the rest evenly distributed between 120 and 35 mm film formats. Less than 20 percent of the entire collection was color.

Arkansas↗

Investigation and control of occupational hazards associated with the use of spirit duplicators.

A Health Hazard Evaluation was conducted by the National Institute for Occupational Safety and Health (NIOSH) to determine if vapors from duplicating fluid (99% methyl alcohol) used in direct-process spirit duplicating machines were causing adverse health effects among teacher aides, or had been responsible for the deaths of three former teacher aides. Death certificates and autopsy data were obtained and evaluated. A self-administered symptom questionnaire was distributed to current teacher aides (exposed group) and to a comparison group of teachers. Fifteen-minute breathing zone air samples for methyl alcohol vapor were collected at operator stations using an infrared gas analyzer. No information supported the claim that the three deaths were related to methyl alcohol exposure. Teacher aides reported significantly more blurred vision, headache, dizziness, and nausea than the comparison group. Concentrations of airborne methyl alcohol ranged from 365-3080 ppm; 15 of 21 measurements exceeded the NIOSH-recommended 15-minute exposure limit of 800 ppm. A mean 96% reduction in vapor concentration was accomplished using inexpensive enclosures and existing room exhaust systems.

Adult↗

Development of a high quality film duplication system using a laser digitizer: comparison with computed radiography.

A high quality film-duplication system was developed in order to improve the image quality of duplicated radiographs and to recover improperly exposed films. The system consists of a laser film digitizer, a laser film printer, a workstation, and a magneto-optical disk. Radiographs are digitized by the laser digitizer, processed by the computer for image enhancement, and then printed on a film by the laser printer. A nonlinear density-correction technique is employed in recovering improperly exposed radiographs using the H&D curve of the screen-film system. Using the new duplication system in our department, the average recovery rate was over 80% for chest and abdominal films rejected due to over- or underexposed. The basic imaging properties of the duplication system were compared with those of a Computed Radiography (CR) system and a conventional screen-film system. For low spatial frequencies, the MTF of the CR system is superior to that of the digital duplication system; however, for high spatial frequencies, the MTF of the duplication system is superior. The noise in the duplication system is about half of that in the CR system.

Biophysical Phenomena↗

Oxidative stress and potential free radical damage associated with photocopying. A role for ozone?

OBJECTIVE: To study the relationship between oxidative stress and potential free radical damage associated with photocopying and to explore a role for ozone emitted during the photocopying process. METHODS: 80 photocopying operators (PO) and 80 healthy volunteers (HV) were enrolled in a random control study design, in which the level of lipoperoxide (LPO, thiobarbituric acid reactive substances, TBARS) in erythrocytes and the levels of vitamin C (VC), vitamin E (VE) and beta-carotene (beta-CAR) in plasma as well as the activities of superoxide dismutase (SOD) and catalase (CAT) in erythrocytes were determined by spectrophotometric methods. RESULTS: Compared with the average values of the above biochemical parameters in the HV group, the average value of LPO (TBARS) in erythrocytes in the PO group was significantly increased (P < 0.0001), while the average values of VC, VE and beta-CAR in plasma as well as those of SOD and CAT in erythrocytes in the PO group were significantly decreased (P < 0.0001). Pearson product-moment correlation analysis showed that with the increase of the ozone level in photocopying sites and the PO duration of exposure to ozone, the level of LPO in erythrocytes in the operators was increased (P < 0.001), while the levels of VC, VE and beta-CAR in plasma as well as the activities of SOD and CAT in erythrocytes in the operators were decreased (P < 0.01-0.0001). CONCLUSION: The findings in this study suggest that ozone causes oxidative damage in copier operatives.

Adult↗

Double-exposure duplication of preoperative and postoperative 2 X 2 transparencies.

Before and after photographs in plastic surgery are an essential part of the patient's record. They also provide visual data to supplement both primary and continuing education lectures. When successive photographs are used in lectures, a sharp visual memory is required to compare effectively the preoperative and postoperative photograph. The method presented in this article uses a specially constructed frame used as an accessory for one of the common commercial slide copiers. This device makes it possible to copy, duplicate, and frame preoperative and postoperative 2 X 2 transparencies onto a single 2 X 2 transparency without any additional work on the original, such as framing, cutting, and remounting. This technique leaves the original preoperative and postoperative 2 X 2 transparency slides intact for possible use elsewhere in the same lecture or subsequent lectures on the same subject.

Audiovisual Aids↗