Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Capillaries”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Capillary dysfunction in striated muscle ischemia/reperfusion: on the mechanisms of capillary "no-reflow".

The major dysfunction of capillaries after prolonged periods of ischemia is the lack of re-establishment of nutritive blood flow upon onset of reperfusion, i.e., capillary no-reflow. Several mechanisms have been proposed to cause capillary no-reflow, including intravascular hemoconcentration and thrombosis, leukocyte plugging, endothelial cell swelling, vasomotor dysfunction, and interstitial edema formation. Electron microscopic studies suggest that thrombus formation and intravascular clotting are not significant mechanisms. Moreover, intravital microscopic studies have demonstrated that plugging of capillaries by leukocytes is not a primary cause for the manifestation of no-reflow in postischemic striated muscle. In contrast, both in vivo studies and histological examinations support the concept that ischemia/reperfusion induces the disruption of the endothelial integrity with loss of fluid to endothelial cells and the interstitial space. As a consequence, these pathological sequelae are associated with intravascular hemoconcentration, endothelial cell swelling and interstitial edema formation, which contribute to capillary lumenal narrowing, increase of hydraulic resistance, and, thus, impairment of perfusion. Whether the postischemic diameter response with dilation of reperfused capillaries and lumenal narrowing of no-reflow capillaries involves endothelin/nitric oxide-triggered capillary pericyte function remains to be determined.

Animals↗

Capillary electrochromatography with segmented capillaries for controlling electroosmotic flow.

Capillaries consisting of two segments each packed with a different stationary phase were introduced for the control and manipulation of the electroosmotic flow (EOF) in capillary electrochromatography (CEC). This kind of column configuration was called segmented capillary where one segment was packed with octadecyl silica (ODS) and served as the separation segment while the other segment was packed with bare silica and functioned as the EOF accelerator segment. The average flow in the segmented capillary increased linearly with increasing fractional length of the EOF accelerator segment, and consequently the analysis time was reduced. Under a given set of conditions, the average flow can be varied over a certain range that extends from the EOF in the individual ODS capillary at the lower end to the EOF in the individual bare silica capillary at the higher end. The pore size of the bare silica in the EOF accelerator segment influenced the average flow in the segmented capillary. Because of the difference in the EOF of the individual segments, the average flow across the segmented capillary is partially degenerated from EOF to viscous flow. Furthermore, the retaining frits in CEC columns are restrictive points which slow down the average flow, thus furthering the degeneration of the flow from EOF to viscous flow. In other words, in CEC columns containing retaining frits, the flow of the mobile phase is not only based on electroosmosis but is contaminated by a viscous component.

Chromatography, Liquid↗

Preparation of capillary columns coated with linear polymer containing hydrophobic and charged groups for capillary electrochromatography.

A linear polymer-coated capillary was prepared by in-capillary copolymerization of N-tert-butylacrylamide (TBAAm) with a charged monomer, 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS), after the capillary pretreatment with a bifunctional reagent. The coated capillaries were applied in capillary electrochromatographic (CEC) separation of small neutral compounds. Hydrophobic groups in the linear polymer, which were immobilized onto the capillary surface, functioned as the stationary phase in reversed-phase CEC separation, and charged groups in the linear polymer generated electroosmotic flow (EOF) along the column. The coated capillaries were prepared by a simple procedure. Moreover, the reproducibility with respect to EOF rate and migration times of the solutes was excellent. The results for CEC separation of small molecules using the linear polymer-coated capillaries are presented.

Acrylamides↗

Capillary zone electrophoresis of biological substances with fused silica capillaries having zero or constant electroosmotic flow.

A series of capillary surface modifications entailing multilayered coatings were introduced and evaluated in capillary zone electrophoresis of biological substances, e.g., proteins, peptides, oligosaccharides and nucleotides. In one set of surface modifications, large molecular weight hydroxypropyl cellulose afforded "zero" flow capillaries, which were used as precursors for developing anodal flow capillaries. When "zero" flow capillaries were further functionalized with a charge polyethyleneimine layer to which a top polyether layer was covalently attached, the resulting anodal electroosmotic flow was relatively weak due to the high viscosity of the coated wall imparted by the hydroxypropyl cellulose layer. Capillaries with relatively strong and constant anodal electroosmotic flow were best achieved when the inner capillary surface was first chemically derivatized with methylated (i.e., quaternarized) polyethyleneimine hydroxyethylated. This hydroxylated and permanently charged polymeric coating yielded constant anodal flow regardless of electrolyte pH. The hydroxyl groups of the charged polymeric coating permitted the covalent attachment of polyether chains, which minimized electrostatic interaction between the positive charges of the polymeric layer and oppositely charged biopolymers. Under these conditions, rapid transport of acidic biopolymers past the detection point in the separation capillary could be achieved, and relatively high plate counts were obtained.

Amino Acid Sequence↗

Studies in capillary zone electrophoresis with a post-column multiple capillary device for fraction collection and stepwise increase in electroosmotic flow during analysis.

A new approach involving the stepwise increase in electroosmotic flow during analysis in capillary zone electrophoresis is introduced and evaluated in the rapid separations of proteins and peptides. The stepwise increase in electroosmotic flow is based on the principle of coupled capillaries in series having different flow characteristics, a concept that was introduced recently by our laboratory. To produce stepwise changes in electroosmotic flow during analysis, a post-column multiple capillary device, which allowed the switching between several coupled capillary systems, was designed and constructed in-house. The utility of the multiple capillary device was also demonstrated and extended to fraction collection of separated analytes in short capillary segments. The fraction collection in capillaries facilitated the quantitative transfer of the collected fractions to high performance liquid chromatography (HPLC) for further analysis or to mass spectrometry (MS) for structural determination. The off-line combination of capillary zone electrophoresis with HPLC or MS utilized commercial instruments without the need of expensive interfacing designs.

Amino Acid Sequence↗

Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated fused-silica capillary

A simple procedure was developed for preparing a carbon-coated fused-silica capillary for use in sheathless capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The tapered capillary tip was smeared with a marker pen before coating with carbon using a soft pencil. The layer from the ink of the marker pen was critical to the preparation of the carbon-coated capillary. The fabrication of a carbon-coated fused-silica capillary tip requires less than 1 min. The stability of this carbon-coated fused-silica capillary is examined, and its utility in on-line sheathless CE/ESI-MS is demonstrated with the separation of berberine, coptisine, and palmatine chlorides. Although the carbon-coated fused-silica capillary tip is not as rugged as a gold-coated capillary, it is durable enough for sheathless CE/ESI-MS applications. Moreover, it is easy to refurbish the column once the performance of the tip is degraded.

Journal Article↗

Use of dynamically coated capillaries for the routine analysis of methamphetamine, amphetamine, MDA, MDMA, MDEA, and cocaine using capillary electrophoresis.

A rapid, accurate, precise, reproducible, economical, and environmentally gentle method using capillary electrophoresis (CE) is presented for the routine analysis of methamphetamine, amphetamine, MDA, MDMA, MDEA, and cocaine in seized drugs. The methodology uses a 32 cm by 50 microm capillary (length to detector 23.5 cm) with a commercially available buffer kit and diode array UV detection. Dynamic coating of the capillary surface is accomplished by flushing with base for 1 min, a proprietary polycation for 1 min, and then a proprietary polyanion for 2 min. This approach provides a relatively high and stable electroosmotic flow (EOF), even at low pHs. The background electrolyte (BGE) contains 75 mM phosphate buffer (pH 2.5) with the same polyanion as above. Using this methodology, amphetamine, methamphetamine, MDA, MDMA, MDEA, and an internal standard (n-butylamphetamine) are baseline resolved in less than 5 min. The run-to-run migration time %RSDs and peak area %RSDs are typically <0.3% and <2.1%, respectively. The day-to-day and capillary-to-capillary migration time %RSDs are <1.5% and <2.1%, respectively. The %RSDs of the relative migration times compared with the internal standard on a day-to-day and capillary-to-capillary basis are <0.2% and <0.06%, respectively. The linear dynamic range using peak areas range from 0.003 to 0.10 mg/mL. The correlation coefficients are >0.9998, with all calibration curves passing at or near the origin. Similar data are obtained for cocaine and its internal standard henyltoloxamine. None of the compounds usually encountered in illicit samples interfere with the target compound (e.g., methamphetamine and cocaine) or the internal standard. Quantitative results for synthetic mixtures and seized exhibits are in good agreement with actual values, and also with results obtained from other techniques. The relatively high EOF for the dynamically coated capillary system allows for the screening of basic, acidic, and neutral adulterants in drug seizures; identification is facilitated by the use of automated UV library searches.

Journal Article↗

Comparison of the use of single capillaries and coupled capillaries based on micellar electrokinetic chromatography (MEKC) and sweeping-MEKC modes.

The use of single capillaries (25 and 50 microm inner diameter (ID)) and coupled capillaries of different diameters (100-50 and 75-25 microm ID) based on micellar electrokinetic chromatography (MEKC) and sweeping-MEKC modes is compared and reported. Naphthalene-2,3-dicarboxaldehyde (NDA)-derivatized dopamine was selected as the model compound by examining the fluorescence intensity when a violet (410 +/- 7 nm, 2 mW) light-emitting-diode (LED) was used as the light source. When a single capillary (50 microm ID) was used, the detection limit for NDA-derivatized dopamine was determined to be 2.0 x 10(-7) M (Signal-to-nose ratio S/N = 3) based on the MEKC mode. This was improved to 4.0 x 10(-9) M when the sweeping-MEKC mode was applied. In addition, this can be further improved to 1.0 x 10(-9) M and 5.6 x 10(-10) M when 100-50 and 75-25 microm ID coupled capillaries are used. The use of the coupled capillary is also helpful for improving the separation efficiency. Based on the sweeping-MEKC mode, the number of theoretical plates (N) for the detected peaks were determined to be 6.3 +/- 2.7 x 10(5) by means of a single capillary (50 microm ID). This can be improved to 9.4 +/- 3.6 x 10(5) and 9.4 +/- 0.9 x 10(6) when the 100-50 and 75-25 microm ID coupled capillaries were applied.

Chromatography, Micellar Electrokinetic Capillary↗

Capillary sieving electrophoresis/micellar electrokinetic capillary chromatography for two-dimensional protein fingerprinting of single mammalian cells.

We have developed a two-dimensional capillary electrophoresis method for the study of protein expression in single mammalian cells. The first-dimension capillary contains an SDS-pullulan buffer system to perform capillary sieving electrophoresis, which separates proteins based on molecular weight. The second-dimension capillary contains an SDS buffer for micellar electrokinetic capillary chromatography. After a 6-min-long preliminary separation, fractions from the first capillary are successively transferred to a second capillary, where they undergo further separation by MECC. Over 100 transfers and second-dimension separations are performed over an approximately 3.5-h-long period. We demonstrate this technology by generating protein fingerprints from single native MC3T3-E1 osteoprogenitor cells and MC3T3-E1 cells transfected with the human transcription regulator TWIST. We also present single-cell protein fingerprints from MCF-7 breast cancer cells before and following treatment to induce apoptosis.

Animals↗

Nailfold capillary density as a possible indicator of pulmonary capillary loss in systemic lupus erythematosus but not in mixed connective tissue disease.

Nailfold capillary density was measured in 24 patients with systemic lupus erythematosus (SLE), 14 with mixed connective tissue disease (MCTD) and 21 healthy subjects. Pulmonary function tests were performed on all subjects and needle muscle biopsies on 12 patients with SLE and 9 with MCTD. A significant correlation was documented between nailfold capillary density and pulmonary gas transfer (KCO) in patients with SLE (p less than 0.001) but not in patients with MCTD. This suggests that in SLE poor gas transfer may be dependent on alveolar capillary loss and that nailfold capillary density may be a good indicator of alveolar capillary density. There was no significant correlation between skeletal muscle fiber atrophy and nailfold capillary density in SLE or MCTD. Additional studies to optimize the nailfold capillary counting method are described.

Adolescent↗

Screening for urinary methadone by capillary electrophoretic immunoassays and confirmation by capillary electrophoresis-mass spectrometry.

This paper characterizes competitive binding, electrokinetic capillary-based immunoassays for urinary methadone using reagents which were commercialized for a fluorescence polarization immunoassay. After incubation of 25 microL urine with the reactants, a small aliquot of the mixture is applied onto a fused-silica capillary and the unbound fluorescein-labeled methadone tracer is monitored by capillary electrophoresis with on-column laser-induced fluorescence detection. Configurations in presence and absence of micelles were investigated, found to be capable of recognizing urinary methadone concentrations > or = 10 ng/mL, and shown to be suitable for rapid methadone screening of patient urines. Based upon shorter run times and a much better separation of free tracer and antibody-tracer complex, conditions without micelles are preferred. For confirmation analysis of urinary methadone and its major metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), capillary electrophoresis in a pH 4.6 ammonium acetate-acetic acid buffer was interphased to an atmospheric pressure ionization triple quadrupole mass spectrometry system. Using positive ion electrospray ionization and the tandem mass spectrometry mode with collision-induced dissociation in the collision cell, fragmentation of the two substances was determined. For confirmation via direct urine injection or application of a urinary extract, in-source fragmentation was employed and the first quadrupole was operated in the selected ion monitoring mode by switching between the masses of relevant precursor/product ion sets for methadone (m/z = 310, 265) and EDDP (m/z = 278, 249, 234). This capillary electrophoresis-mass spectrometry approach is shown to permit the confirmation of methadone and EDDP in patient urines that tested positive for methadone using electrokinetic capillary-based immunoassays, a fluorescence polarization immunoassay, and capillary electrophoresis with UV absorption detection.

Electrophoresis, Capillary↗

Electrochemical detection in capillary electrophoresis with dual-parallel on-capillary electrodes.

A new approach for dual electrode electrochemical detection in capillary electrophoresis (CEEC) is described. In this approach, two identical capillaries, each containing an on-capillary electrode incorporated permanently onto its tip, were paired together for simultaneous sample injection and detection. This procedure permitted dual-parallel detection to be performed without the need for painstaking alignment of the electrodes with respect to one another and to the capillary outlet as is required for the off-capillary microelectrode systems usually employed in CEEC. As a result, independent detection at two electrodes held at different potentials or at two electrodes of different composition or structure could be performed simply and with wide flexibility. Fabrication of on-capillary electrodes was carried out by sputter-coating the exit end of the capillaries with a thin layer of Au or Pt. Dual electrode system performance was demonstrated by separation and analysis of phenol and catechol samples. In addition, the detection system was coupled with glucose oxidase for the selective detection of glucose.

Catechols↗

Isolation of intact capillaries and capillary plasma membranes from frozen human brain.

The development of methods for the isolation of brain capillaries and brain capillary plasma membranes makes possible biochemical studies of the blood-brain barrier (BBB), which is made up of brain capillaries. Studies aimed at assessing the role of the BBB in the pathogenesis of specific neurologic diseases, e.g., Alzheimer's disease or multiple sclerosis, will necessitate the isolation of capillaries from brain involved with specific pathology. Such tissue is most readily available from banks containing frozen human brain. The present studies show that intact capillaries and capillary plasma membranes can be isolated from frozen human brain, including as little as five g of multiple sclerosis plaque tissue. Capillaries from frozen human brain are enriched in gamma-glutamyl transpeptidase, factor VIII antigen, and a 46K protein which has recently been shown to be a BBB-specific protein. These studies provide the basis for future biochemical studies of human brain microvessels in neurologic disease.

Aged↗

Enzymophoresis of nucleic acids by tandem capillary enzyme reactor-capillary zone electrophoresis.

Enzymophoresis with coupled heterogeneous capillary enzyme reactor-capillary zone electrophoresis was developed and evaluated in the area of nucleic acids. Ribonuclease T1, hexokinase and adenosine deaminase were successfully immobilized on the inner walls of short fused-silica capillaries through glutaraldehyde attachment. These open-tubular capillary enzyme reactors were quite stable for a prolonged period of use under operation conditions normally used in capillary zone electrophoresis. The capillary enzyme reactors coupled in series with capillary zone electrophoresis served as peak locator on the electropherogram, improved the system selectivity, and facilitated the quantitative determination of the analytes with good accuracy. Also, they allowed the on-line digestion and mapping of minute amounts of transfer ribonucleic acids, and the simultaneous synthesis and separation of nanogram quantities of oligonucleotides.

Adenosine Deaminase↗

On-capillary complexation of metal ions with 4-(2-thiazolylazo)resorcinol in capillary electrophoresis.

Co(II), Zn(II), Ni(II) and Fe(I) were successfully separated by capillary electrophoresis using pre-capillary and on-capillary complexation with 4-(2-thiazolylazo)resorcinol. The influences of some crucial parameters, including both pre- and on-capillary complexation procedure, were investigated. For on-capillary complexation, the complexing reaction was carried out inside the capillary by mixing the zones of ligand and sample during the electrophoretic migration. Compared with pre-capillary complexation, the method provided 30-fold reduction in detection limits for Co(II), 50-fold reduction for Zn(II), and 100-fold reduction for Ni(II) and Fe(II). It was used for the analysis of a pharmaceutical and tap water sample.

Azo Compounds↗

Optimization of capillary coating by hydroxyethyl methacrylate for capillary zone electrophoresis of proteins.

This work describes further improvements of coating fused silica capillaries with 2-hydroxyethyl methacrylate (HEMA) by atom transfer radical polymerization (ATRP). First, endcapping with a sterically less bulky silanyl reagent reduces the electrosmotic flow (EOF) by 25% in addition to the 40% EOF reduction caused by HEMA coating compared to a bare fused silica capillary. An additional hydrolysis step was introduced into the preparation of HEMA coated capillaries and leads to better reproducible migration times. The influence of the solvent during ATRP and the resulting polymer coating was investigated by replacement of DMF with water or water-methanol mixtures. The quality of the optimized coating was characterized by protein separations at pH 3. HEMA coated capillaries reveal up to 746000 plates. The polyvinyl alcohol (PVA) coated capillary provides only half of this efficiency. A long-term test at pH 9 shows good stability of the HEMA coated capillaries in basic medium. Also the numbers of plates in this medium was about 30% higher than for separations with the PVA capillary. In addition, the phosphate buffer was replaced by a volatile ammonium acetate buffer for later use with mass spectrometry (MS).

Buffers↗

Applications of a sulfonated-polymer wall-modified open-tubular fused-silica capillary in capillary zone electrophoretic separations.

A fused-silica capillary that is wall-modified via chemically bonding a sulfonated polymer to the capillary wall has a uniform negative charge density on its surface and produces an electroosmotic flow (EOF) greater than 4 x 10(-4) cm2 V(-1) s(-1) The EOF is nearly independent of buffer pH over the pH range of 2 to 10 and is lower than the EOF obtained for the bare fused-silica capillary at the more basic pH but is higher at the more acidic buffer pH. Optimization of buffer pH can be based on analyte pKa values to improve the overall quality of the capillary zone electrophoresis (CZE) separation of complex mixtures of weak acid and base analytes. Because of the high EOF in an acidic buffer, the capillary is useful for the separation of weak organic bases which are in their cation forms in the acidic buffer. EOF for the sulfonic acid bonded phase capillary can be adjusted via buffer additives such as organic solvent, tetraalkylammonium salts, multivalent cations and alkylsulfonic acids. The advantages of utilizing buffer pH and the EOF buffer modifiers to enhance migration time, selectivity, and resolution in CZE separations with this capillary are illustrated using a series of test analyte mixtures of inorganic anions, carboxylic acids, alkylsulfonic acids, benzenesulfonic acids, sulfas, pyridines, anilines or small-chain peptides.

Alkanesulfonic Acids↗

Separation of proteins and peptides by capillary electrochromatography in diol- and octadecyl-modified etched capillaries.

This study involves the evaluation of a capillary electrochromatography method based on etching the inner walls of a fused-silica tube, which is subsequently modified by a silanization/hydrosilation reaction scheme. Two different organic moieties, octadecyl and diol, are attached to the etched capillary wall. The performance of these two columns is compared to a bare capillary using peptide (angiotensins) and protein samples. It is concluded that the etching process increases the surface area of the inner wall sufficiently to induce solute-bonded phase interactions for the capillaries modified with the octadecyl and diol moieties. The separation capabilities of the two modified capillaries are not the same, presumably due to differences in the chemical properties of the two ligands. When compared to a bare capillary where separation is due only to electrophoretic mobility effects, the bonded etched capillaries also exhibit significant differences in separation factors for the same solutes under identical experimental conditions.

Angiotensin I↗