Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “BIOPSIES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Effect of peripheral biopsies in maximising early prostate cancer detection in 8-, 10- or 12-core biopsy regimens.

OBJECTIVE: To assess the cancer detection rate per individual core biopsy in a 12-core protocol and develop an optimal biopsy regimen for detecting early prostate cancer. PATIENTS AND METHODS: The study included 445 new patients who had a 12-core transrectal ultrasonography (TRUS)-guided prostatic biopsy over a 40-month period. The 12- core biopsy protocol included parasagittal sextant and six peripheral biopsies. The cancer detection rate per individual core was evaluated to give an optimal biopsy protocol. RESULTS: Prostate cancer was detected in 142 patients (31.9%). Parasagittal sextant biopsy would have failed to detect 40 (28.2%) of the cancers. Among the various possible biopsy protocols, the optimum 10-core biopsy strategy excluding the parasagittal mid-zone biopsies from the 12-core protocol achieved a cancer detection rate of 98.6%. CONCLUSION: The cancer detection rate increased from 71.8% for parasagittal sextant biopsies to 88.7% by adding peripheral basal biopsies (8-biopsy protocol); 98.6% of cancers in the series would have been detected with a 10-biopsy strategy omitting the parasagittal mid-zone biopsies. Thus we recommend a 10-core protocol incorporating six peripheral biopsies in patients with elevated age- specific prostate-specific antigen levels (2.6-10.0 ng/mL) for maximising cancer detection.

Adult↗

Use of three additional mid biopsies to improve local assessment of prostate cancer in patients with one positive sextant biopsy.

OBJECTIVES: Routine sextant biopsies have proven useful in the diagnosis and local staging of prostate cancer. A single positive biopsy is more frequently associated with a smaller tumor and a low risk of positive margins. Nevertheless, the risk of positive margins in patients with 1 positive sextant biopsy remains high (20%). A better assessment of local invasion is therefore needed. In addition to standard sextant biopsies, we routinely obtain 3 additional mid biopsies from the apex to the base of the prostate. The aim of this study is to analyze the contribution of these 3 additional mid biopsies to local staging. METHODS: From 1988 to 1996, 177 men underwent sextant biopsies plus 3 additional mid biopsies prior to radical prostatectomy; 59 men had 1 positive sextant biopsy, and 13 also had 1-3 positive mid biopsies. The pathological results of the prostatectomy specimens from these 13 men (group A) were compared with those of the 46 men with only 1 positive sextant biopsy (group B), by means of the Fisher and Mann-Whitney tests. RESULTS: The two groups were similar in terms of age, preoperative prostate-specific antigen, the Gleason score of positive biopsies, the weight of the specimen, the Gleason specimen score, tumor volume and pathological stage. Positive surgical margins were found in 53.8% of group A and 19.4% of group B patients (p = 0.002). The location of the positive additional biopsies matched that of the positive surgical margins. CONCLUSIONS: Additional mid biopsies improve the local assessment of prostate cancer in patients with a single positive sextant biopsy, identifying significantly more positive margins when these additional mid biopsies are positive and indicating the location of the positive surgical margins. These informations could be helpful to avoid positive surgical margins during radical prostatectomy.

Aged↗

Are endoscopic biopsies of small bowel as good as suction biopsies for diagnosis of enteropathy?

BACKGROUND: Endoscopy is increasingly used in paediatric practice for diagnosis of enteropathy, although the quality of grasp forceps-obtained biopsy specimens required for reliable diagnosis has been questioned in comparison with suction capsule biopsy specimens. This study prospectively compared the diagnostic suitability of grasp forceps biopsy versus suction biopsy in the same patient during the same procedure. METHODS: A double-port paediatric suction biopsy capsule was front-loaded onto an endoscope and directed to the fourth part duodenum-proximal jejunum for biopsy sampling. Subsequently, three grasp biopsy specimens were taken from the same region. All biopsies were coded, photographed, and measured for area, using computed morphometry. A single blinded histopathologist assessed sample adequacy for diagnosis. Twenty-nine patients were enrolled (age range, 8-185 months). RESULTS: On three occasions the suction capsule failed to fire, and on four occasions only one sample was obtained. Three grasp biopsy specimens were obtained on each occasion by endoscopy, and the first two were used for comparison with suction biopsy samples. Median total area of individual biopsy samples obtained by the two procedures was not different (21.3 vs. 22.5 mm2; P = 0.027). Muscularis mucosae was obtained more commonly with grasp biopsies (P<0.001), and no difference was observed for the presence of three or more villus-crypt units, degree of haemorrhage, or optimal orientation. Two suction biopsy procedures and one grasp biopsy procedure were inadequate for diagnosis. CONCLUSIONS: Endoscopic grasp biopsies are perfectly adequate for the assessment of small intestinal histology. In addition, endoscopy affords advantage in diagnosis of other upper gastrointestinal disease with avoidance of radiologic screening involved with the suction capsule technique.

Adolescent↗

Stereotactic core needle biopsy of mammographic breast lesions as a viable alternative to surgical biopsy.

BACKGROUND: Stereotactic needle biopsy technique has received considerable attention as a possible alternative to surgical biopsy of nonpalpable breast lesions. The exact role of this procedure in the management of mammographic breast lesions has not yet been accurately defined. METHODS: Data have been collected prospectively on 416 patients over an 8-month period (January 1992 through August 1992). Of 416, 356 patients underwent only stereotactic breast biopsy with a 14-gauge needle. Sixty patients underwent stereotactic breast biopsy followed by surgical biopsy. Based on mammographic findings before biopsy, lesions were classified as benign (24%), likely benign (49%), malignant (2%), likely malignant (6%), and indeterminate (19%). The number of core biopsy specimens obtained from each patient ranged from one to six. RESULTS: The specimen was considered adequate in 98% of cases. Complications were minimal. The tissue diagnosis was benign in 92% and malignant in 8% of patients. In those patients undergoing surgical and stereotactic biopsy, 57 of 60 had matching histopathological results, representing an agreement rate of 95% (p < 0.001). The three patients whose histopathological results did not match had malignant diagnoses on stereotactic biopsy that were subsequently not identified in the modified radical mastectomy specimen because the entire focus of malignancy was removed by the several passes made by the core needle during biopsy. No patient had a negative stereotactic biopsy result in whom malignancy was later detected by surgical biopsy. CONCLUSIONS: This study indicates excellent agreement between surgical and stereotactic needle biopsy findings. Stereotactic biopsy with a 14-gauge needle could obviate the need for surgical biopsy in certain women with radiologically benign, likely benign, and indeterminate lesions.

Algorithms↗

Percutaneous testis biopsy: an alternative to open testicular biopsy in the evaluation of the subfertile man.

PURPOSE: We evaluated the safety and efficacy of percutaneous testis biopsy by comparing the ultrasound appearance and histological status of testicular parenchyma obtained to those noted after open testis biopsy. MATERIALS AND METHODS: A total of 51 consecutive infertile men with azoospermia or severely impaired semen quality, in whom ductal obstruction was suspected, underwent percutaneous (31) or open (20) testis biopsy, with 58 and 34 procedures performed, respectively. Scrotal ultrasound was performed preoperatively, and at 2 weeks and 1, 3 and 6 months after biopsy. In addition, immunoglobulins G and A antisperm antibody assays were obtained preoperatively and postoperatively. Two biopsy specimens were obtained from each testis for formal histological evaluation. A touch preparation was also performed and examined immediately for mature spermatozoa using phase contrast microscopy. RESULTS: All biopsies yielded adequate tissue for diagnosis and morphometric analysis. Of 58 percutaneous biopsies 4 (7%) demonstrated sonographic evidence of intratesticular bleeding, characterized by a hypoechoic region within the testicular parenchyma, which resolved by 6 months postoperatively. In contrast, 10 of 34 open biopsies (29%) showed evidence of intratesticular bleeding or a new area of increased echogenicity at 1 month after the procedure (intraparenchymatous scar). All intraparenchymatous scars persisted to 6 months postoperatively. No patient undergoing percutaneous or open testis biopsy had antisperm antibodies in the seminal fluid or serum (azoospermia cases) or on sperm postoperatively. Of the 32 and 20 patients undergoing percutaneous and open testis biopsy 3 (9%) and 14 (70%), respectively, required narcotic analgesia. All patients returned to routine activities within 24 hours after percutaneous testis biopsy. No postoperative infections or extratesticular hematomas were noted. Pathological study was diagnostic in all specimens. CONCLUSIONS: Percutaneous testis biopsy is well tolerated by the patient, with fewer apparent complications than and diagnostic value equal to open testis biopsy. Percutaneous testis biopsy should be considered an alternative to open biopsy.

Biopsy↗

Is extended 11-core biopsy valuable in benign prostatic hyperplasia patients with intermediate serum prostate-specific antigen (4.1-10 ng/ml) and prior negative sextant biopsy?

OBJECTIVE: To evaluate the importance of extended 11-core biopsy in benign prostatic hyperplasia (BPH) patients with intermediate prostate-specific antigen (PSA; 4.1-10 ng/ml) and prior negative sextant biopsy. MATERIAL AND METHODS: A total of 381 BPH patients with intermediate PSA (4.1-10 ng/ml) and prior negative sextant biopsy underwent extended 11-core biopsy, which included conventional sextant biopsy in addition to five cores from three alternative sites. Two cores were taken from the right and left anterior horns of the peripheral zone (PZ), two from the right and left anterior transition zones (TZs) and one from the midline of the PZ. Overall, 315 patients were subjected to transurethral resection of the prostate (n = 272) or open prostatectomy (n = 43). RESULTS: Repeat 11-core biopsy revealed prostate cancer in 66/381 cases (17.3%). The distribution of positive cores on repeat 11-core biopsy was as follows: sextant biopsy sites only in 50% of cases (33/66); alternative sites only in 31.8% (21/66); and sextant plus alternative biopsy sites in 18.2% (12/66). The anterior horn of the PZ was the most frequently positive alternative site (25/33; 75.8%), followed by the TZ (5/33; 15.2%), while the midline site was involved in 9% of cases (3/33). Eleven-core biopsy had a significantly better cancer detection rate compared to sextant biopsy when digital rectal examination was normal (p = 0.009), prostate volume was in the range 30-50 cm (p = 0.033) and PSA density was > or =0.15 (p = 0.024). Six cancer cases out of 315 (1.9%) were diagnosed as a result of the definitive pathology. The sensitivity of 11-core biopsy was 91.6%, compared to 62.5% for sextant biopsy (p < 0.001). CONCLUSION: An extended 11-core biopsy protocol is valuable in BPH patients with intermediate PSA (4.1-10 ng/ml) and prior negative sextant biopsy as it significantly improved the overall detection rate in our study by 32% (p = 0.019).

Age Distribution↗

Parotid gland biopsy compared with labial biopsy in the diagnosis of patients with primary Sjogren's syndrome.

OBJECTIVE: To assess the value of the parotid biopsy as a diagnostic tool for primary Sjögren's syndrome (pSS), and to compare the parotid biopsy and the labial biopsy with regard to diagnostic value and biopsy-related morbidity. METHODS: In 15 consecutive patients with pSS and 20 controls, the parotid biopsy was assessed as a diagnostic tool based on the presence of lymphocytic foci, benign lymphoepithelial lesions and lymphoid follicles. These new histological criteria were compared with established diagnostic criteria for the labial biopsy in 35 consecutive patients suspected for pSS who underwent simultaneous biopsies from both sites. In addition, both biopsies were compared for morbidity. RESULTS: The first analysis revealed a focus score of >or=1 or lymphocytic infiltrates (not fulfilling the criterion of a focus score of 1) combined with benign lymphoepithelial lesions as diagnostic criteria for pSS. When comparing the parotid biopsy with the labial biopsy sensitivity and specificity were comparable (sensitivity 78%, specificity 86%). Level of pain was comparable and no loss of motor function was observed. No permanent sensory loss was observed after parotid biopsy, while labial biopsy led to permanent sensory loss in 6% of the patients. Malignant lymphoma was detected in one parotid biopsy by chance, without involvement of the labial salivary gland. CONCLUSION: A parotid biopsy has a diagnostic potential comparable with that of a labial biopsy in the diagnosis of pSS, and may be associated with less morbidity.

Biopsy↗

High-grade prostatic intraepithelial neoplasia on needle biopsy: risk of cancer on repeat biopsy related to number of involved cores and morphologic pattern.

The importance of isolated high-grade prostatic intraepithelial neoplasia (HGPIN) on needle biopsy is its association with synchronous invasive carcinoma. The relevance of this relationship has been called into question in recent years. In our study, we examined whether the histologic subtype of HGPIN (ie, tufting, micropapillary, cribriform, flat) and/or the number of core biopsies involved by HGPIN was predictive of a subset of men who were at higher risk of having invasive carcinoma on follow-up biopsies. We examined 200 sets of needle biopsies with a diagnosis of isolated HGPIN. Patient age ranged from 46 to 90 years (mean 66.4 years). The breakdown of the histologic subtypes of HGPIN is as follows: tufting 59%, micropapillary 34.3%, cribriform 6.2%, and flat 0.5%. A total of 132 patients (66%) had follow-up biopsies. Prostatic adenocarcinoma was identified in 28.8% of patients with 89.5% of cancers identified on the first two follow-up biopsies. For men that had two or more cores with HGPIN on the initial biopsy, 35.9% eventually had cancer on follow-up whereas men with only single core involvement had cancer in 22% of cases. Men with tufting/flat HGPIN on the initial biopsy had cancer on follow-up in 31.9% of cases, whereas the micropapillary/cribriform subtype was associated with cancer in 22% of follow-up biopsies. The histologic findings on the first repeat biopsy can be quite informative as to the risk of synchronous invasive carcinoma. Of the men with HGPIN on the first repeat biopsy, 32% eventually had cancer on follow-up. Additionally, if multiple cores were involved by HGPIN on the first repeat biopsy, the risk of finding cancer was 50%, regardless of single or multiple core involvement on the initial biopsy. Men with a benign diagnosis on the first repeat biopsy had a 14% risk of having cancer on follow-up. These data indicate that the multiple core involvement by HGPIN, both on initial and first repeat biopsy, defines a subset of men that are at increased risk of harboring synchronous invasive carcinoma. The histologic subtype of PIN does not appear to be as informative.

Adenocarcinoma↗

Prostate cancer detection with office based saturation biopsy in a repeat biopsy population.

PURPOSE: Patients at increased risk for prostate cancer with previously negative biopsies pose a diagnostic challenge. We have previously demonstrated that extensive saturation biopsy can be performed in an office setting. We now report the diagnostic yield of office saturation biopsy in patients at increased risk for prostate cancer and at least 1 negative prior biopsy. MATERIALS AND METHODS: We performed saturation prostate biopsy with local anesthesia in the office in 116 patients with at least 1 prior negative biopsy and with certain risk factors, namely persistently elevated prostate specific antigen, abnormal digital rectal examination, or prior atypia or PIN on prior biopsy. RESULTS: A total of 34 cancers were detected for an overall diagnostic yield of 29%. A 64% detection rate was noted when a patient had undergone a single prior sextant biopsy. Subgroup analysis revealed a cancer detection rate of 41% when only prior sextant biopsies were performed, and a 24% detection rate when 10 or more cores were taken on prior biopsy. The detection rate was 33% when only 1 prior biopsy was taken and it was 24% when 2 or more prior biopsies were performed. CONCLUSIONS: Saturation biopsy can be performed safely and effectively in the office with a significant diagnostic yield even in patients with previous extended biopsy schemes. We believe that it should be the next diagnostic step after an initial negative biopsy in patients in whom the diagnosis of prostate cancer is strongly suspected.

Aged↗

Increased accuracy of biopsy Gleason score obtained by extended needle biopsy.

PURPOSE: Accurate tumor grading is critical for adequate prostate cancer treatment. Nonetheless, the Gleason score of standard sextant biopsy correctly predicts the Gleason score of the radical prostatectomy specimen in about 50% of cases. We investigated if extended needle biopsy could improve biopsy Gleason score accuracy. MATERIALS AND METHODS: Laparoscopic transperitoneal radical prostatectomy was performed in 135 patients. Prostate cancer was diagnosed in 89 cases by standard sextant transrectal (6 to 8 cores) biopsy and in 46 by extended needle (12 core transperineal under transrectal guidance) biopsy. Preoperative evaluation included digital rectal examination, prostatic specific antigen measurement, transrectal ultrasonography and endorectal coil magnetic resonance imaging in all patients. All biopsy and prostatectomy specimens were reviewed by a single pathologist. RESULTS: Clinical characteristics were similar in the 2 groups. The concordance between prostate biopsy and radical prostatectomy Gleason score was 32 of 46 cases (70%) and 44 of 89 (49%) for 12 core and standard transrectal biopsy, respectively (z test p = 0.0127). Biopsy under grading was found in 11 of 46 cases (24%) and 35 of 89 (39%) (z test p = 0.0366), and biopsy over grading was found in 3 of 46 (6%) and 10 of 89 (11%) (z test p = 0.1894) with 12 core and standard transrectal biopsy, respectively. Primary Gleason pattern was predicted exactly by biopsy in 40 of 46 cases (87%) and 56 of 89 (63%) with 12 core and standard sextant biopsy, respectively (z test p = 0.0018). CONCLUSIONS: Extended needle biopsy significantly increases the accuracy of biopsy Gleason score for assessing final prostate cancer grade.

Biopsy, Needle↗

Importance of peripheral biopsies in maximising the detection of early prostate cancer in repeat 12-core biopsy protocols.

OBJECTIVE: To assess cancer-detection rates in repeat 12-core biopsy protocols, as extended multicore prostate biopsy protocols have become standard when investigating men with a raised prostate-specific antigen (PSA) level, but repeat prostate biopsy protocols are still developing. PATIENTS AND METHODS: During a 4.5-year period, 241 of 590 patients with persistently high age-specific PSA levels of 2.6-10 ng/mL and an initial benign biopsy were invited for repeat transrectal ultrasonography-guided 12-core prostatic biopsy. The protocol for repeat biopsy was identical to the first biopsy, and included a periprostatic nerve block. The first six biopsies were obtained from the periphery of the gland directed more laterally at the base, mid-zone and apices. The remainder were parasagittal sextant biopsies. Pathological findings were analysed on an individual core basis. RESULTS: The mean age of the 241 men was 63.4 years; cancer was diagnosed in 40 (16.6%) on repeat biopsy. Men with cancer were older and had a higher median PSA level. The median Gleason score was 6, with a median of two cores positive for cancer. Maximum cancer detection rates were from peripheral apices (37.5%), basal biopsies had the lowest detection rates (23.8% and 16.3%), and parasagittal biopsies missed 35% of detected cancers. Patients with cancer also had significantly lower prostate volumes and higher PSA densities (both P < 0.001). CONCLUSION: A low cancer yield from both peripheral basal and parasagittal basal specimens on repeat biopsy indicates adequate sampling at initial biopsy. The maximum cancer yield in the peripheral mid-zones and apical zones suggests the necessity for concentrated sampling of these zones in repeat biopsy protocols.

Adult↗

Biopsy proven and biopsy negative temporal arteritis: differences in clinical spectrum at the onset of the disease. Groupe de Recherche sur l'Artérite à Cellules Géantes.

OBJECTIVES: To assess the clinical features of biopsy proven and negative biopsy temporal arteritis at the time of diagnosis and during a three year follow up. METHODS: Newly diagnosed cases of giant cell arteritis were included in a prospective, multicentre study. Initial clinical and biological features, season of diagnosis, and cardiovascular events occurring during the follow up were recorded. Biopsy proven and negative biopsy cases were compared. RESULTS: Two hundred and seven biopsy proven, and 85 negative biopsy cases were included from 1991 to 1997. Fifty eight per cent of the biopsy proven cases, compared with 39.29% of the negative biopsy cases, were diagnosed during the autumn or winter (p = 0.003). Visual problems (31.5%, v 19.1%, p = 0.031), blindness (9.7% v 2.38%, p = 0.033), jaw claudication (40.8%, v 28.243%, p = 0.044), and temporal artery palpation abnormalities (61.3% v 29.5%, p = 7.10(-7)) were more frequent in the biopsy proven than in the negative biopsy group. Less specific symptoms, such as headache (82.5% v 92. 9%, p = 0.021), or associated polymyalgia rheumatica (40.1% v 65.9%, p = 9 x 10(-5)) were more prevalent in the negative biopsy cases. Biological markers of inflammation were significantly more increased in the biopsy proven group. All cases of blindness occurring after treatment belonged to the biopsy proven group. CONCLUSION: Biopsy proven cases seem to be more severe than biopsy negative cases at the time of diagnosis and during follow up. Seasonal difference at diagnosis may suggest a different aetiological pattern.

Aged↗

Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast.

OBJECTIVE: The purpose of this study was to compare the outcome of sonographically guided core biopsies performed with the 14-gauge automated gun with the outcome of those performed with the 11-gauge vacuum-assisted device. Outcome was defined in terms of missed tumors, the need (both immediate and delayed) for a second biopsy, histologic underestimation, and complication rates. MATERIALS AND METHODS: We retrospectively reviewed all sonographically guided core biopsies performed between January 1997 and August 2001. Before February 2000, biopsies were performed using the 14-gauge automated gun and after that time, with either the 14-gauge automated gun or the 11-gauge vacuum-assisted device. During the study period, 181 biopsies were performed with the 14-gauge automated gun and 100 with the 11-gauge vacuum-assisted device. RESULTS: The histologic results of the core biopsies were similar for the group who underwent biopsy with the 14-gauge automated gun and the group who underwent biopsy with the 11-gauge vacuum-assisted device: malignant, 19% versus 19%; benign, 78% versus 79%; and high-risk lesion or other, 3% versus 2%, respectively (p > 0.7). Complications were rare and similar for both methods: 2% for the 14-gauge automated gun and 3% for the 11-gauge vacuum-assisted device (p = 0.46). A second biopsy was recommended immediately after the first in 14% of the patients who underwent biopsy with the 14-gauge automated gun versus 17% of those who underwent biopsy with the 11-gauge vacuum-assisted device (p = 0.47). Recommendation for delayed rebiopsy due to interval change occurred in 2.5% of the patients who underwent biopsy with the 14-gauge automated gun method and 3% of those who underwent biopsy with the 11-gauge vacuum-assisted device (p = 0.94). CONCLUSION: No significant differences were found in the outcomes of sonographically guided core biopsies performed with the automated gun compared with those performed with the vacuum-assisted device in terms of missed cancers, underestimation, complications, or the need (immediate or delayed) for a second biopsy.

Biopsy, Needle↗

Prostate cancer diagnosis using a saturation needle biopsy technique after previous negative sextant biopsies.

PURPOSE: We hypothesized that markedly increasing the number of cores obtained during prostate needle biopsy may improve the cancer detection rate in men with persistent indications for repeat biopsy. MATERIALS AND METHODS: We performed saturation ultrasound guided transrectal prostate needle biopsy in 224 men under anesthesia in an outpatient surgical setting in whom previous negative biopsies had been performed in the office. The mean number of previous sextant biopsy sessions plus or minus standard deviation before saturation biopsy was 1.8 (range 1 to 7). A mean of 23 saturation biopsy cores (range 14 to 45) were distributed throughout the whole prostate, including the peripheral, medial and anterior regions. Indications for repeat biopsy were persistent elevated serum prostate specific antigen (PSA) in 108 cases, persistent elevated PSA and abnormal rectal examination in 27, persistent abnormal rectal examination in 4, high grade prostatic intraepithelial neoplasia in the previous biopsy in 64 and atypia in the previous biopsy in 21. RESULTS: Cancer was detected in 77 of 224 patients (34%). The number of previous negative sextant biopsies was not predictive of subsequent cancer detection by saturation biopsy. Median PSA was 8.7 ng./ml. and median PSA velocity was 0.63 ng./ml. yearly. Of the 77 patients in whom cancer was detected radical prostatectomy was performed in 52. Pathological stage was pT2 in 48 patients and pT3 in 4, while Gleason score was 4 to 5, 6 to 7 and 8 in 5, 46 and 1, respectively. At prostatectomy median cancer volume was 1.04 cc and 85.7% of removed tumors were clinically significant, assuming a 3-year doubling time. The overall complication rate for saturation needle biopsy was 12% and hematuria requiring hospital admission was the most common event. CONCLUSIONS: Saturation needle biopsy of the prostate is a useful diagnostic technique in men at risk for prostate cancer with previous negative office biopsies. This technique allows adequate sampling of the whole prostate gland and has a detection rate of 34% in this cohort of patients.

Adenocarcinoma↗

Comparative evaluation of bone marrow aspirate particle smears, biopsy imprints, and biopsy sections.

Bone marrow aspirate particle smears, biopsy imprints, and biopsy sections were compared to determine the accuracy of the three samples in assessing for overall cellularity, differential cell count, megakaryocyte density, iron stores, and tumor infiltration. Aspirate particle smears and biopsy imprints were stained by Wright-Giemsa method. Aspirate particle smears were also stained with Prussian-blue. Biopsy sections were 1 1/2-2 micron thick and were prepared from non-decalcified plastic embedded samples and stained with combined Prussian-blue-hematoxylin-eosin, and Giemsa. One hundred-eight sets of specimens from 99 patients were examined. In 20 cases, chi-square analysis showed a comparable degree of cellularity (p less than 0.001) and megakaryocyte density (p less than 0.001) among the three preparations. Differential count comparison by regression analysis indicated that mean percentages of neutrophilic cells in the proliferation compartment were comparable in the three groups (p less than 0.01). A better correlation was obtained among the three groups in the percent neutrophilic cells in the maturation-storage compartment, normoblasts, eosinophils, and plasma cells (p less than 0.001). Lymphocytes in the aspirate smears correlated with the biopsy imprints (p less than 0.01) but not with the biopsy sections (p greater than 0.05). Monocytes did not correlate in any of the groups (p greater than 0.05). In 47 cases, chi-square analysis of iron stores in the aspirate particle smears correlated well with those in the biopsy sections (p less than 0.001). Fifty-two marrows that were done for staging nonhematological malignancies revealed malignant cells in 21 cases, biopsy sections were positive in all, biopsy imprints were positive in 19 (90%), and aspirate particle smears were positive in 7 (33%). Thirty-six marrows done for staging non-Hodgkin's lymphoma showed malignant cells in 13 cases. Twelve (92%) biopsy sections, three (23%) biopsy imprints, and nine (69%) aspirate particle smears contained lymphoma cells. In conclusion, a satisfactory evaluation of marrow samples for diagnostic studies can be achieved by examination of biopsy sections along with aspirate particle smears or biopsy imprints. Any of the three marrow preparations alone is not sufficient for accurate diagnosis in all cases. The biopsy imprint is an accurate modality for identifying nonhematological tumor metastasis in the bone marrow.

Biopsy↗

Monofocal and plurifocal high-grade prostatic intraepithelial neoplasia on extended prostate biopsies: factors predicting cancer detection on extended repeat biopsy.

OBJECTIVES: To evaluate factors predicting cancer detection by extended repeat prostate biopsies in patients with an initial, isolated, monofocal or plurifocal, high-grade prostatic intraepithelial neoplasia (HGPIN) diagnosis. METHODS: From 1995 to 2002, after a first set of 10 to 12 systematic biopsy cores, 47 patients with an initial HGPIN diagnosis underwent repeat biopsy using the same technique (mean repeat biopsy cores 11.5) after a median follow-up of 11.4 months (range 3 to 24). RESULTS: Cancer was detected at the second biopsy in 21 patients (44.6%). Cancer detection was significantly greater in patients with plurifocal HGPIN than in those with monofocal HGPIN (70% vs. 10%, respectively; P <0.005) and in patients who underwent repeat biopsy more than 6 months after the first biopsy set (65%) compared with patients who underwent repeat biopsy within 6 months (25%; P <0.01; mean follow-up 15.5 and 3.8 months, respectively). Multivariate analysis showed that prostate-specific antigen, prostate-specific antigen density, digital rectal examination, and transrectal ultrasound findings were not statistically significant predictors of prostate cancer, and HGPIN multifocality and interval between biopsies (more than a 6-month follow-up interval) were independent prognostic factors (odds ratio 4.65 and 2.65, respectively). After radical prostatectomy (14 patients), no statistically significant differences were found in the pathologic stage between patient groups stratified by repeat biopsy interval (within or after 6 months). CONCLUSIONS: After a 10 to 12-core biopsy, patients with initial, isolated monofocal or plurifocal HGPIN diagnoses had an overall cancer detection rate of 45% on repeat extended biopsies. Plurifocal HGPIN on the first biopsy set was the strongest independent predictive factor in cancer detection. A 12 to 18-month interval before repeat biopsy could permit a significantly greater cancer detection rate, with no apparent likelihood of clinical cancer progression.

Aged↗

Will the spectrum of lesions prompting a "B3" breast core biopsy increase the benign biopsy rate?

AIM: To audit the benign surgical biopsies in women screened, assessed, and referred by the Leeds/Wakefield Breast Screening Unit for the year 1999-2000 with a view to determining any association with a preoperative B3 core biopsy categorisation. METHODS: The results of all preoperative diagnostic procedures in all patients who underwent surgical excision for a lesion proving benign in the year 1999-2000 were reviewed. Cases were categorised according to whether the preoperative fine needle aspirate cytology (FNAC) or core biopsy had been equivocal or of uncertain malignant potential (C3/B3), inadequate or unrepresentative (C1/B1), or benign (C2/B2). In those cases with a C3/B3 FNAC or core biopsy result, reasons for the uncertainty were determined by examination of the report and, where necessary, slides. In cases with C1/B1 or C2/B2 investigations and in those without a preoperative procedure, the reasons for surgical referral were determined from the screening records. Case records of all patients with a B3 core biopsy categorisation who subsequently proved to have malignancy were also reviewed. RESULTS: Thirty six women had benign surgical biopsies in the 1999-2000 screening year. In 13 of the 36 patients, referral for diagnostic biopsy rested on radiological and/or pathological suspicion of radial scar. The core biopsy category was B3 in all but one, which was in the B1 category. In a further 10 patients, referral was based primarily on a pathological B3 categorisation. The reasons for this were as follows: papillary lesion (two), fibroepithelial lesion (two), atypical intraductal epithelial proliferation (two), stromal mucin (two), atypical lobular hyperplasia (one), and an unusual vascular lesion (one). Two cases with a C3 on FNAC also derived from papillary lesions. In the remaining nine patients, the radiological features were sufficiently suspicious to prompt referral in the presence of either inadequate/unrepresentative (C1/B1) or benign (B2) preoperative pathological findings. Two women had no preoperative needle biopsy. CONCLUSIONS: In 22 of 36 benign biopsies, the initial core biopsy categorisation was B3. According to the current system of core biopsy categorisation, a diversity of lesions must be designated as of "uncertain malignant potential" (B3) because the technique provides insufficient tissue for full histological assessment. The use of this category may increase the number of benign biopsies if all such cases are referred for surgery. An increase in the benign biopsy rate may be averted if larger amounts of tissue can be obtained using newer vacuum assisted techniques such as the Mammotome.

Biopsy↗

Pleural mesothelioma: sensitivity and incidence of needle track seeding after image-guided biopsy versus surgical biopsy.

PURPOSE: To retrospectively compare the sensitivity of image-guided core-needle biopsy, thoracoscopy, and thoracotomy in the diagnosis of malignant pleural mesothelioma and to retrospectively determine the incidence of needle track seeding after these procedures. MATERIALS AND METHODS: Institutional review board approval was obtained, and informed consent was not required. The study included 100 consecutive patients (81 men, 19 women; average age, 65.8 years) with pathologically proved malignant pleural mesothelioma who were treated between 1994 and 2002. A total of 23 core-needle biopsies were performed in 22 patients, and 11 of these biopsies were coupled with fine-needle aspiration biopsy. A coaxial technique was used, and biopsy was performed with fluoroscopic (12 biopsies), computed tomographic (10 biopsies), or ultrasonographic (one biopsy) guidance. Sixty-nine patients underwent surgical biopsy in the form of thoracoscopy (n = 51) and/or thoracotomy (n = 21). Patients were followed up clinically for any evidence of needle track seeding after image-guided or surgical procedures. The sensitivity of diagnostic procedures and the incidence of needle track seeding as a result of intervention were calculated. RESULTS: Sensitivity was 86% for image-guided core-needle biopsy, 94% for thoracoscopy, and 100% for thoracotomy. The incidence of needle track seeding was 4% for image-guided core-needle biopsy and 22% for surgical biopsy. CONCLUSION: Image-guided core-needle biopsy in patients with malignant pleural mesothelioma has a lower incidence of needle track seeding than surgical biopsy and has a high sensitivity for diagnosis.

Adult↗