Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Miniaturized sample preparation and separation methods for environmental and drug analyses.

Miniaturized extraction and separation media have been successfully developed from precisely controlled technologies. In this article, recent developments in these high performance analytical methods, such as miniaturized sample preparation methods and the coupling of these techniques with microscale separation systems, have been reviewed, along with some applications to environmental and biological analysis. The advantage of the miniaturization is not only for the environmental compatibility but also for the developments of the high performance analytical systems. Down-sizing also makes it possible to investigate and introduce various compounds and materials as novel media (such as tailor-made materials and devices) in separation science. As a typical example of the novel miniaturized sample preparation system, the applications of fibrous materials for microcolumn liquid-phase separation methods are described.

Environmental Monitoring↗

Sampling, sample preparation, and analytical variability associated with testing wheat for deoxynivalenol.

The variability associated with testing wheat for deoxynivalenol (DON) was measured using a 0.454 kg sample, Romer mill, 25 g comminuted subsample, and the Romer Fluoroquant analytical method. The total variability was partitioned into sampling, sample preparation, and analytical variability components. Each variance component was a function of the DON concentration and equations were developed to predict each variance component using regression techniques. The effect of sample size, subsample size, and number of aliquots on reducing the variability of the DON test procedure was also determined. For the test procedure, the coefficient of variation (CV) associated with testing wheat at 5 ppm was 13.4%. The CVs associated with sampling, sample preparation, and analysis were 6.3, 10.0, and 6.3%, respectively. For the sample variation, a 0.454 kg sample was used; for the sample preparation variation, a Romer mill and a 25 g subsample were used; for the analytical variation, the Romer Fluoroquant method was used. The CVs associated with testing wheat are relatively small compared to the CV associated with testing other commodities for other mycotoxins, such as aflatoxin in peanuts. Even when the small sample size of 0.454 kg was used, the sampling variation was not the largest source of error as found in other mycotoxin test procedures.

Algorithms↗

Simultaneous development of six LC-MS-MS methods for the determination of multiple analytes in human plasma.

Traditional sequential single analyte method development is both time-consuming and labor-intensive. In this report, a concept of simultaneously developing multiple liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS) methods were proposed. Mass spectrometric and chromatographic conditions as well as sample preparation methods for all analytes were optimized concurrently. Mass spectrometric conditions for six analytes, i.e. clonidine (CLO), albuterol (ALB), fentanyl (FEN), ritonavir (RIT), naltrexone (NAL), and loratadine (LOR), were established simultaneously using the Sciex Analyst software. LC-MS-MS sensitivities obtained using gradient elution methods on reversed-phase Inertsil ODS3 and normal phase Betasil silica columns were compared. Sample extraction methods using protein precipitation, liquid/liquid extraction, or solid-phase extraction (SPE) were evaluated. Recovery of analytes was determined. Matrix effects and interference due to endogenous compounds were investigated. Selection of a potential internal standard was discussed.

Albuterol↗

A direct determination of thymidine triphosphate concentrations without dephosphorylation in peripheral blood mononuclear cells by LC/MS/MS.

A rapid, sensitive and specific analytical method with minimal sample preparation for the measurement of thymidine triphosphate (TTP) in peripheral blood mononuclear cells (PBMC) by LC/MS/MS has been developed. PBMC were separated from whole blood or buffy coat. The analyte and internal standard were extracted from PBMC with 70% methanol (pH 7.2). These extracts after centrifugation were directly injected onto LC/MS/MS without need for any further sample preparation. The calibration curve was linear over the range 0.8-800 ng/ml. Mean inter- and intra-assay coefficients of variation (CVs) over the range of the standard curve were less than 10%. The overall recovery of TTP was 103.5%.

Calibration↗

Detection of the isoflavone aglycones genistein and daidzein in urine using solid-phase microextraction-high-performance liquid chromatography-electrospray ionization mass spectrometry.

An improved method of detection of the isoflavone aglycones, genistein and daidzein, is reported using solid-phase microextraction-high-performance liquid chromatography-electrospray ionization mass spectrometry (SPME-HPLC-ESI-MS). Extraction of the isoflavonoids from urine using SPME with a Carbowax-templated resin fiber coating allows rapid preconcentration of the analytes without the usual sample preparation required by other methods. Detection of the analytes is accomplished by HPLC-ESI-MS. Analysis of spiked samples of urine resulted in a linear range of 0.25 to 250 ng/ml for daidzein and 0.27 to 27.0 ng/ml for genistein. Limits of detection of daidzein and genistein were measured at 25.4 pg/ml for daidzein and 2.70 pg/ml for genistein. Daidzein and genistein were detected in urine following consumption of a soy drink.

Chromatography, High Pressure Liquid↗

Preparation and characterization of chemically defined oligomers of rabbit immunoglobulin G molecules for the complement binding studies.

Pure dimers, trimers, tetramers and pentamers of rabbit non-immune IgG (immunoglobulin G) or antibody IgG were prepared by polymerization in the presence of the bifunctional cross-linking reagent dithiobis (succinimidylpropionate). Oligomerization was performed either in the presence of polysaccharide antigen and specific monomeric antibody (method A) or by random cross-linking of non-immune rabbit IgG in the absence of antigen (method B). By repeated gel-filtration chromatography, samples prepared by both methods exhibited a single band in analytical sodium dodecyl sulphate/polyacrylamide-gel electrophoresis. The electrophoretic mobilities of samples prepared by method A were slightly greater than those for the corresponding samples prepared by method B. This might suggest a role played by antigen in the orientation of IgG molecules within the clusters, which may be more compact than those formed by random cross-linking. The average numbers of cross-linker molecules per oligomer varied between 3 and 6 for clusters made by method A and between 1 and 3 for clusters made by method B. Ultracentrifugal analyses of the oligomers yielded sedimentation coefficients (S20,w) of 9.6S for the dimer, 11.2S for the trimer, 13.6S for the tetramer and 16.1S for the pentamer. Comparison of the observed sedimentation coefficients with those predicted by various hydrodynamic models suggested these oligomers possessed open and linear structures. Reduction of the cross-linking molecules converted oligomers into monomeric species of IgG. C.d. spectra of some oligomers studied in the range 200-250 nm were essentially the same as that of monomeric IgG molecules, thus strongly suggesting no major conformation changes in IgG molecules within clusters. These oligomers were found to be stable for up to 2 months when stored at -70 degrees C.

Animals↗

Interlaboratory and intralaboratory variabilities in the Environmental Lead Proficiency Analytical Testing (ELPAT) Program.

The Environmental Lead Proficiency Analytical Testing (ELPAT) Program evaluates over 400 laboratories that perform lead measurements in paints, soils, and dusts. A previous National Institute for Occupational Safety and Health study, based on the ELPAT data over a 3-year period (1992-1995), found no large biases among common hotplate and microwave digestion techniques, but did detect small consistent bias between two common instrumental methods. This study expands on the earlier study by examining the total sample variability and its variation components (interlaboratory and intralaboratory). A correlation model was used to separate the variation components by estimating a variation ratio. The correlation model leads to a more general approach than a sample pairing technique developed by Youden. This study found no significant evidence that the relative contribution of intralaboratory and interlaboratory variability to total variability changes with lead loading levels. There were no significant differences in the relative contribution of variation components among three most commonly used analytical methods (combinations of sample preparation techniques and instrumental methods). The interlaboratory relative standard deviation is about 1.7 times the intralaboratory relative standard deviation. Both variation components are important parts of total variation although the laboratory-to-laboratory (including analyst-to-analyst) difference is greater than the within laboratory (including sample-to-sample) variation.

Chemistry Techniques, Analytical↗

Methods for gas chromatography-olfactometry: a review.

Gas chromatography-olfactometry methods are used in flavor research to determine the odor active compounds in foods. In this review, the four major methods for gas chromatography-olfactometry are described and their potentials and limitations discussed. The methods include dilution analysis, detection frequency methods, posterior intensity methods and time-intensity methods. The value of gas chromatography olfactometry data is shown to depend directly on the gas chromatography-olfactometry method, as well as on sample preparation and analytical conditions. Each of the methods has been used frequently and has its advantages and disadvantages. However, on the methodological side, a considerable area is still to be explored, which would contribute to the interpretation of the data and would improve the value of these techniques for both fundamental and applied research.

Chromatography, Gas↗

Extractionless method for the determination of urinary caffeine metabolites using high-performance liquid chromatography coupled with tandem mass spectrometry.

Caffeine is metabolised in humans primarily by cytochromes P450 1A2 and 2A6, xanthine dehydrogenase/oxidase, and N-acetyltransferase 2. The activities of these enzymes show a large variation due to genetic polymorphisms and/or induction by xenobiotics. Ratios of different caffeine metabolites in urine or other body fluids are frequently used to characterise the individual/actual activity of these enzymes. The common analytical method involves extensive sample preparation, followed by HPLC-UV. The presence of numerous other UV-absorbing chemicals in body fluids affects the sensitivity and selectivity of this method. We have developed an HPLC-electrospray-MS-MS method for the determination of 11 caffeine metabolites and two internal standards after a simple, extractionless preparation. Blank urine, obtained after 5 days on a methylxanthine-free diet, contained small amounts of some caffeine metabolites, but no other components producing any confounding signals. Eleven metabolites and internal standards were recovered at 90 to 110% after addition to the blank urine (0.1 to 2.5 micro M in the final sample involving a 20-fold dilution of urine) in the 0.1-2.5 micro M concentration range. Other metabolites, 5-acetylamino-6-amino-3-methyluracil (AAMU) and 5-acetylamino-6-formylamino-3-methyluracil (AFMU), were detected with similar recovery and precision, but required higher concentrations (3 to 30 micro M). AFMU was completely converted into AAMU by a short alkalisation of urine. The method was explored in six healthy individuals after consuming coffee (4 mg caffeine per kg body mass). These experiments demonstrated the simplicity, high sensitivity and selectivity of the method under conditions used for phenotyping.

Caffeine↗

[Preparation and quantitative analysis of methyl phenyl carbonate standard sample].

The preparation and quantitative analytical method for high-purity methyl phenyl carbonate (MPC) was developed. Dimethyl carbonate (DMC) and diphenyl carbonate (DPC) were firstly used as reactants to synthesize MPC catalyzed by TiO2/SiO2 because the disproportionation of MPC is reversible and the reverse reaction is thermodynamically favorable. The high-purity MPC standard sample was obtained by reduced pressure distillation and the removal of minor phenol with dilute sodium hydroxide solution. The qualitative analysis by gas chromatography-mass spectrometry (GC-MS) showed there were minor phenol and diphenyl carbonate in the MPC sample. The mass percent concentration of water in the MPC sample was 0.26%, which was determined by Karl Fischer titration. A gas chromatographic method with an OV-101 capillary column was established for quantifying the minor phenol and DPC in the MPC sample. The quantitative results showed the mass concentrations of phenol and DPC were 2.04% and 1.59%, respectively. The difficulty to analyze MPC, the intermediate product of the transesterification of DMC and phenol, was solved with the self-made MPC standard sample.

English Abstract↗

MALDI-TOF mass spectrometry of insoluble giant polycyclic aromatic hydrocarbons by a new method of sample preparation

The insolubility of giant polycyclic aromatic hydrocarbons (PAHs) prevents their characterization by conventional analytical methods, which require a solubilization of the analyte. Laser desorption mass spectrometry may be used to analyze insoluble samples but is limited to relatively low molecular weights (approximately 2000), in the case of PAHs. To overcome this limitation, we applied MALDI-TOF mass spectrometry. Since MALDI sample preparation also requires solubility of analyte and matrix molecules, the sample preparation needed modification. The giant PAHs (>2000 Da) were investigated after using a new sample preparation, consisting of mechanically mixing analyte and matrix without any solubilization procedures. This solvent-free process allows insoluble compounds to be characterized. Furthermore, new organic molecules can be used as a matrix. Indeed, 7,7,8,8-tetracyanoquinodimethane, a new matrix with promising properties, has proven to be particularly suitable for the measurement of PAHs. Thanks to the successful characterization with MALDI-TOF mass spectrometry, the chemical design of giant PAHs, which was hindered until now for a lack of analytical methods, can now continue to develop.

Journal Article↗

Polyamines and polyamine complexes: analytical comments.

Different methods of sample preparation for determination of di- and polyamines (putrescine, spermidine, spermine) and their conjugates in serum, plasma, and urine are discussed. Higher polyamine values obtained after hydrolysis of serum or plasma acidic extracts suggest the presence of polyamine conjugates. Additional polyamines might be bound to proteins and released by hydrolysis of the crude samples. Biological studies of bound polyamines in health and disease will require procedures for quantitative analysis. For the pertinent measurements, radioimmunoassays employing antibodies developed against isolated polyamine conjugates may prove useful.

Acetylation↗

Application of column-switching liquid chromatography-tandem mass spectrometry for the determination of pharmaceutical compounds in tissue samples.

Information on plasma-tissue distribution which is important for drug development may be obtained by "in silico" prediction tools. To support the validation of computer models, drug concentrations in rat plasma and tissues (brain, liver, kidney, testes, spleen, gut, lung. heart, muscle, skin and fat) had to be determined. In our work, we established analytical assays for a variety of substances including nicardipine, nitrendipine, felodipine and benzodiazepines. Sample preparation had to be simple and method development as well as analytical run time short to allow a high sample throughput and to minimize resources. Column-switching HPLC after homogenization and protein precipitation served as an efficient, easy and rapid sample preparation method, followed by selective MS-MS detection. Optimization of the trapping procedure was performed in order to reduce the influence of endogenous interferences and to obtain good recovery. Chromatographic separation was necessary to increase the selectivity. The use of small analytical column dimensions (2.1 x 10 mm) was investigated to achieve higher sample throughput without compromising the assay quality. Mass spectrometric parameters, such as ionization modes (positive vs. negative) and ion source types (TurbolonSpray vs. APCI) were screened to find suitable conditions for sensitive analysis of the compounds. Matrix suppression effects were taken into consideration. Calibration samples were prepared in plasma only, whereas quality control samples were prepared in both plasma and tissues to save animals and time. Accuracy and precision were in the range of 84.4-119.1% and 1-16.5%, respectively. Limits of quantification were in the range of 0.5-2.5 ng/ml for plasma and 2-10 ng/ml for tissues. Run times as short as 2.2 min could be achieved.

Animals↗

Comparison of human whole blood, plasma, and serum matrices for the determination of perfluorooctanesulfonate (PFOS), perfluorooctanoate (PFOA), and other fluorochemicals.

Interest in human exposure to perfluorinated acids, including perfluorobutanesulfonate (PFBS), perfluorohexanesulfonate (PFHS), perfluorooctanesulfonate (PFOS), and perfluorooctanoate (PFOA) has led to their measurement in whole blood, plasma and serum. Comparison of measurements in these different blood-based matrices, however, has not been rigorously investigated to allow for across-matrix comparisons. This research evaluated concentrations of PFBS, PFHS, PFOS, and PFOA in whole blood collected in heparin (lithium) and ethylenediamine tetraacetic acid (EDTA), plasma samples collected in heparin and EDTA, and serum (from whole blood allowed to clot). Blood samples were collected from 18 voluntary participants employed at 3M Company. Solid phase extraction methods were used for all analytical sample preparations, and analyses were completed using high-pressure liquid chromatography/tandem mass spectrometry methods. Serum concentrations ranged from: limit of quantitation (LOQ, 5 ng/mL) to 25 ng/mL for PFBS; LOQ (5 ng/mL) to 75 ng/mL for PFHS; LOQ (5 ng/mL) to 880 ng/mL for PFOS; and LOQ (5 or 10 ng/mL) to 7320 ng/mL for PFOA. Values less than the LOQ were not included in the statistical analyses of the mean of the ratios of individual values for the matrices. PFBS was not quantifiable in most samples. Serum to plasma ratios for PFHS, PFOS, and PFOA were 1:1 and this ratio was independent of the level of concentrations measured. Serum or plasma to whole blood ratios, regardless of the anticoagulant used, approximated 2:1. The difference between plasma and serum and whole blood corresponded to volume displacement by red blood cells, suggesting that the fluorochemicals are not found intracellularly or attached to the red blood cells.

Adult↗

Characterization of condom lubricant components using Raman spectroscopy and Raman chemical imaging.

A condom can be described as a protective sheath used as a contraceptive or to protect against sexually transmitted diseases. However, individuals also use condoms during the commission of sexual assaults to prevent identification through deposited biological material. Raman spectroscopy offers a novel approach to identifying the presence of condom lubricant components. Furthermore, Raman chemical imaging expands on conventional Raman spectroscopy to characterize multiple condom lubricant components simultaneously in a manner that effectively demonstrates heterogeneous sample mixtures both spectrally and spatially. Known reference materials, liquid and solid lubricant components of common condom brands were successfully characterized using Raman dispersive spectroscopy and Raman chemical imaging without extensive sample preparation inherent to other analytical methods. The characterization of these materials demonstrates the potential of this technique to become a routine screening method for condom lubricants. This preliminary investigation provides a basis for future studies to determine the feasibility of Raman spectroscopy and Raman chemical imaging for condom lubricant trace detection in case type samples.

Condoms↗

Sampling wheat for deoxynivalenol.

The variability associated with testing wheat for deoxynivalenol (DON) was measured using a 0.454 kg sample, a Romer mill, 25 g of comminuted subsample and the Romer Fluoroquant analytical method. The total variability was partitioned into sampling, sample preparation, and analytical variability components. Each variance component was found to be a function of the DON concentration and equations were developed to predict each variance component using regression techniques. The effects of sample size, subsample size, and number of aliquots on reducing the variability of the DON test procedure were also determined. Using the test procedure described above, the coefficient of variation (CV) associated with testing wheat at 5 ppm DON was found to be 13.4%. The CVs associated with sampling, sample preparation, and analysis were 6.3, 10.0, and 6.3%, respectively. The sample variations associated with testing wheat are relatively small when compared to CVs associated with testing other commodities for other mycotoxins such as aflatoxin in peanuts. Even with the use of a small sample size (0.454 kg), the sampling variation was not the largest source of error as found in other mycotoxin test procedures.

Algorithms↗

Quantitative determination of helicid in rat plasma by liquid chromatography-electrospray ionization mass spectrometry and its application to preliminary pharmacokinetic studies.

A sensitive and selective liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the identification and quantification of helicid in rat plasma. The method was based on simple liquid-liquid extraction (LLE). A Kromasil C18 column (150mmx2.00mm, 3.5microm) was used as the analytical column, while a mixture of acetonitrile and 500microM ammonium chloride was used as the mobile phase. MS detection was performed using a single quadrupole mass spectrometer in a negative selected ion monitoring (SIM) mode. The deprotonated molecules [M+Cl](-) at m/z 319.00 and 363.05 were used to quantify helicid and bergeninum (internal standard, I.S.), respectively. The lower limit of quantification of helicid was 1ng/ml. The method was linear in the concentration range of 1-1000ng/ml. The intra-day and inter-day precisions (R.S.D.%) were within 10.0% for the analyte. Helicid proved to be stable during all sample storage, preparation and analytical periods. The method was successfully applied to a pharmacokinetic study in rats after intragastric administration of helicid with a dose of 50mg/kg. Only 50microl of rat plasma at each sampling time was needed for analysis. The proposed method enables unambiguous identification and quantification for the preliminary pharmacokinetic studies of helicid.