Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AIR CONDITIONING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Consistent pattern of elevated symptoms in air-conditioned office buildings: a reanalysis of epidemiologic studies.

Published studies of the relation between type of building ventilation system and work-related symptom prevalence in office workers have been contradictory. A reanalysis was performed of six studies meeting specific eligibility criteria, combining published data with unpublished information obtained from study authors. Five eligible studies were from the United Kingdom, and one was from Denmark. Standardized categories of building ventilation type were created to allow comparison of effects across studies. Within each study, prevalence odds ratios (PORs) were calculated for symptoms in each ventilation category relative to a baseline category of naturally ventilated buildings. Air-conditioned buildings were consistently associated with increased prevalence of work-related headache (POR = 1.3-3.1), lethargy (POR = 1.4-5.1), and upper respiratory/mucus membrane symptoms (POR = 1.3-4.8). Humidification was not a necessary factor for the higher symptom prevalence associated with air-conditioning. Mechanical ventilation without air-conditioning was not associated with higher symptom prevalence. The consistent associations found between type of building ventilation and reported symptom prevalence have potentially important public health and economic implications.

Air Conditioning↗

The occurrence and persistence of mixed biofilms in automobile air conditioning systems.

Twelve automobile air conditioner systems from six manufacturers and three countries, selected mostly because of complaints of unpleasant odors in the passenger compartment, were examined for microbial growth by direct microscopy and enrichment culture. Mixed populations of fungi and bacteria (with occasional protozoa) were observed in biofilms in at least some of the components from all used units. The aluminum heat exchanger fins from ten evaporators demonstrated bacterial biofilms that yielded Methylobacterium mesophilicum. Penicillium viridicatum colonized components from four units. These bacteria and fungi were recoverable repeatedly from these units during 'dry' storage of up to 27 months. This report associates a bacterial-fungal community with disagreeable air quality in some automobiles.

Air Conditioning↗

Highly integrated system solutions for air conditioning.

Starting with the air handling unit, new features concerning energy efficient air treatment in combination with optimisation of required space were presented. Strategic concepts for the supply of one or more operating suites with a modular based air handling system were discussed. The operating theatre ceiling itself, as a major part of the whole integrated system, is no longer a simple air outlet: additional functions have been added in so-called media-bridges, so that it has changed towards a medical apparatus serving as a daily tool for the physicians and the operating staff. Last and not least, the servicing of the whole system has become an integral part of the facility management with remote access to the main functions and controls. The results are understood to be the basis for a discussion with specialists from medical and hygienic disciplines as well as with technically orientated people representing the hospital and building-engineering.

Air Conditioning↗

Air-conditioned environments do not prevent deterioration of human semen quality during the summer.

OBJECTIVE: To determine if air conditioning might mitigate summer reductions in semen quality. DESIGN: Prospective study of semen quality in summer and winter. SETTING: Normal human volunteers were studied in the setting of a fertility laboratory. PATIENTS, PARTICIPANTS: Two groups of volunteers were selected from the vicinity of New Orleans: 64 men who worked indoors during the summer in air-conditioned environments and 76 others who worked outdoors. INTERVENTIONS: None. MAIN OUTCOME MEASURES: Parameters of manual semen analysis were examined for seasonal and group differences. RESULTS: Remarkably similar reductions in semen quality during summer as compared with winter were observed in both indoor and outdoor workers, respectively, with regard to the following parameters of semen quality: 19% and 19% in sperm concentration, 25% and 27% in total sperm per ejaculate, 17% and 20% in motile sperm concentration, 13% and 15% in percent sperm with normal morphology, and 23% and 23% in concentration of morphologically normal motile sperm. CONCLUSIONS: These findings do not support the hypothesis that the heat of the summer is detrimental to male reproductive capacity. The available evidence suggests instead a possible role of photoperiod in causing the seasonal changes in semen quality.

Adolescent↗

[Fungi and bacteria on air filters from heating, ventilation and air-conditioning systems: a method for determination of fungi and bacteria on air filters].

A method was developed for the determination of microorganism concentrations on air filters of HVAC systems, and the influence of different test parameters on the microbiological results was examined by considering various used air filters from several such systems. Microorganisms are detected by shaking air filter samples in fluid, where their concentration is then determined as surface cultures. Since varying the shaking time (30, 60, 90 min) had no influence on the quantitative microorganism determination, a shaking time of 60 minutes was chosen for detection of bacteria, yeasts and moulds. Incubation of blood agar plates either for 4 days at 20 degrees C +/- 2 degrees C or for 2 days at 36 degrees C +/- 1 degree C yielded identical concentrations of bacteria and yeasts. Since results obtained with malt extract agar and Czapek-Dox agar are comparable, one of the two culture media is sufficient for the quantitative determination of moulds on air filters. For statistical evaluation, the inoculation of three parallel agar plates per growth medium was found to be adequate, and the arithmetic mean and the median proved to be equivalent. Investigation on the detection rate showed that, on the average, the method developed demonstrated 80% of the microorganisms detectable on an air filter sample. Thus a simple method is available for quantitative determination of microorganisms on air filters.

Agar↗

Volatile organic compounds associated with microbial growth in automobile air conditioning systems.

Volatile organic compounds from Penicillium viridicatum and Methylobacterium mesophilicum growing on laboratory media and on component materials of automobile air conditioners were analyzed with gas chromatography and mass spectrometry. P. viridicatum produced compounds such as 4-methyl thiazole, terpenes and alcohols, whereas M. mesophilicum produced dimethyl disulfide, dimethyl trisulfide, and chlorophenol with growth on laboratory media. In comparison with laboratory media, fewer volatiles were detected from colonized foam insulation materials. Biofilms of M. mesophilicum on aluminum evaporator components produced mainly dimethyl disulfide. These biofilms, after inoculation with P. viridicatum, produced offensive smelling alcohols and esters such as 2-methyl propanol, 3-penten-2-ol, and the ethyl ester of butanoic acid. The moisture and substrates innate to the automobile air conditioning systems provided an environment suitable for microbial biofilm development and odor production. Reduction of retained moisture in the air conditioning system coupled with use of less susceptible or antimicrobial substrates are advised for remediation of the noxious odors.

Air Conditioning↗

Air conditioning systems.

There are some basic requirements for air conditioning systems in operating theatres. 1. Obviously the regulation of temperature and humidity is necessary, but cleaning of fresh air and circulating air is much more important. 2. Concerning cleaning, a high standard of filtration of air is demanded to avoid contamination of wounds. 3. So far only HEPA-filters, a technical description, give security and safety. They filter particles down to under 1 micrometer and have a filtration rate of more than 99.9%. 4. The ventilation rate is directly related to the germ concentration in the air. The higher the ventilation rate the cleaner the air during working. 5. To avoid turbulences unidirectional or uniform flow is necessary. This technique has become popular as the laminar flow technique. To get such a flow an air flow velocity of 0 45 +/- 0.1 m/s is necessary. 6. The arrangement of the different working places in an operating theatre is very important. Instrument tables and the operation field itself have to be in the zone of first air. 7. One of the commonest germ dispersion sources is the human body. Proper dressing and behaviour have to be observed. The airflow behind a person (in laminar cross flow) or under a person (in laminar down flow for instance when the neurosurgeon bends his head over the operating field) has to be regarded as contaminated. 8. Hygienic controls must be made in the operation theatre when unused and also under working conditions, in a sophisticated manner. If all these points are respected a real clean room technique is possible with considerable lowering of the risk of infection for the patient. Obviously all the other rules of hygiene, i.e., asepsis and antisepsis, elaborated since the days of Lister, have to be strictly respected.

Air Conditioning↗

Air conditioning and source-specific particles as modifiers of the effect of PM(10) on hospital admissions for heart and lung disease.

Studies on acute effects of particulate matter (PM) air pollution show significant variability in exposure-effect relations among cities. Recent studies have shown an influence of ventilation on personal/indoor-outdoor relations and stronger associations of adverse effects with combustion-related particles. We evaluated whether differences in prevalence of air conditioning (AC) and/or the contribution of different sources to total PM(10) emissions could partly explain the observed variability in exposure-effect relations. We used regression coefficients of the relation between PM(10) and hospital admissions for chronic obstructive pulmonary disease (COPD), cardiovascular disease (CVD), and pneumonia from a recent study in 14 U.S. cities. We obtained data on the prevalence of AC from the 1993 American Housing Survey and data on PM(10) emissions by source category, vehicle miles traveled (VMT), and population density from the U.S. EPA. We analyzed data using meta-regression techniques. PM(10) regression coefficients for CVD and COPD decreased significantly with increasing percentage of homes with central AC when cities were stratified by whether their PM(10) concentrations peaked in winter or non-winter months. PM(10) coefficients for CVD increased significantly with increasing percentage of PM(10) emission from highway vehicles, highway diesels, oil combustion, metal processing, decreasing percentage of PM(10) emission from fugitive dust, and increasing population density and VMT/mile(2). In multivariate analysis, only percentage of PM(subscript)10(/subscript) from highway vehicles/diesels and oil combustion remained significant. For COPD and pneumonia, associations were less significant but the patterns of the associations were similar to that for CVD. The results suggest that air conditioning and proportion of especially traffic-related particles significantly modify the effect of PM(10) on hospital admissions, especially for CVD.

Air Conditioning↗

The effects of season, climate, and air-conditioning on the prevalence of Dermatophagoides mite allergens in household dust.

BACKGROUND: Clinical evidence reveals a strong relationship between dust mite allergen levels and asthma. This study suggests the relative importance and interactions among factors that influence mite allergen levels in human dwellings. METHODS: Dermatophagoides pteronyssinus allergen (Der p I) and D. farinae allergen (Der f I) were measured in 536 dust samples collected from 424 homes across the United States. RESULTS: There were distinct seasonal fluctuations of Der p I and Der f I. Der p I rapidly increased to peak in July then gradually decreased through October. Der f I slowly rose to peak later, around September, before declining. Different climates in regions of the United States had no significant affect on the quantity of Der p I or Der f I. However, regional climate differences seemed to influence the prevalence of either D. pteronyssinus or D. farinae. Air-conditioning significantly reduced (p < 0.001) Der I mite allergens detected in the dust samples, and a tendency existed for Der f I to be higher than Der p I in air-conditioned homes. There was a significant (p < 0.01) interaction between air-conditioning and seasons. The most dramatic affect was observed during the summer months, the cooling season, from approximately May to September. CONCLUSIONS: These findings show that distinct seasonal fluctuations exist of D. pteronyssinus and D. farinae mite populations, and suggest that differences in the microclimate within homes may have a dramatic affect on Dermatophagoides mite populations.

Air Conditioning↗

Airborne irritant contact dermatitis due to synthetic fibres from an air-conditioning filter.

We describe 8 cases of occupational airborne irritant contact dermatitis in intensive care unit (ICU) employees caused by synthetic (polypropylene and polyethylene) fibres from an air-conditioning filter. Not until a workplace investigation was conducted, was it possible to clarify the unusual sequence of events. High filter pressure in the intensive care air-conditioning system, maintained to establish an outward airflow and prevent microorganisms from entering the ward, probably caused fibres from the filter to become airborne. Upon contact with air-exposed skin, fibres subsequently provoked skin irritation. Test periods in the ICU with varying filter pressures, in an attempt to improve environmental conditions, led to even higher filter pressure levels and more complaints. The sometimes-very-low humidity might have contributed to development of skin irritation. The fact that most patients recovered quickly after treatment with emollients and changing the filters made it most likely that the airborne dermatitis was of an irritant nature.

Adult↗

[Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

Air Conditioning↗

Interaction of temperature, humidity, driver preferences, and refrigerant type on air conditioning compressor usage.

Recent studies have shown large increases in vehicle emissions when the air conditioner (AC) compressor is engaged. Factors that affect the compressor-on percentage can have a significant impact on vehicle emissions and can also lead to prediction errors in current emissions models if not accounted for properly. During 1996 and 1997, the University of California, Riverside, College of Engineering-Center for Environmental Research and Technology (CE-CERT) conducted a vehicle activity study for the California Air Resources Board (CARB) in the Sacramento, CA, region. The vehicles were randomly selected from all registered vehicles in the region. As part of this study, ten vehicles were instrumented to collect AC compressor on/off data on a second-by-second basis in the summer of 1997. Temperature and humidity data were obtained and averaged on an hourly basis. The ten drivers were asked to complete a short survey about AC operational preferences. This paper examines the effects of temperature, humidity, refrigerant type, and driver preferences on air conditioning compressor activity. Overall, AC was in use in 69.1% of the trips monitored. The compressor was on an average of 64% of the time during the trips. The personal preference settings had a significant effect on the AC compressor-on percentage but did not interact with temperature. The refrigerant types, however, exhibited a differential response across temperature, which may necessitate separate modeling of the R12 refrigerant-equipped vehicles from the R134A-equipped vehicles. It should be noted that some older vehicles do get retrofitted with new compressors that use R134A; however, none of the vehicles in this study had been retrofitted.

Air Conditioning↗

[Optimal air conditioning in the classrooms of secondary schools as a factor of improving health status of schoolchildren].

Proceeding from the analysis and statistical processing of the data derived during the study of health dynamics of junior schoolchildren, who studied during an academic year under the conditions of different air exchange regimes (20 and 40 m3 of air per hr/child), it was established that indoor air medium formed by air supply of 40 m3 per hr/child (compared to 20 m3) even during a year had a favorable impact on the functional state of some body systems and prevalence of acute diseases among schoolchildren.

Air Conditioning↗