Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Torso”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49Linked to original sources

High-resolution 1H NMR spectroscopy in a live mouse subjected to 1.5 Hz magic angle spinning.

It is demonstrated that the resolution of the (1)H NMR metabolite spectrum in a live mouse can be significantly enhanced by an ultraslow magic angle spinning of the animal combined with a modified phase-corrected magic angle turning (PHORMAT) pulse sequence. Proton NMR spectra were measured of the torso and the top part of the belly of a female BALBc mouse in a 2 T field while spinning the animal at a speed of 1.5 Hz. It was found that even in this relatively low field, with PHORMAT an isotropic spectrum is obtained with line widths that are a factor of 4.6 smaller than those obtained in a stationary mouse. It is concluded that in vivo PHORMAT has the potential to significantly increase the utility of (1)H NMR spectroscopy for biochemical and biomedical animal research.

Animals↗

The field dependence of NMR imaging. II. Arguments concerning an optimal field strength.

Some of the factors involved in the choice of field strength for NMR imaging are examined. The influences of relaxation times and chemical shift upon image quality and signal-to-noise ratio are highlighted, and power deposition is introduced as a significant factor which may limit the flexibility and information available at higher fields as long as 180 degrees echo pulses continue to be necessary. Chemical-shift imaging is examined and found wanting as a means of coping with chemical-shift artifacts, and the use of multiple echoes (albeit with research) in conjunction with multiple-slice techniques is advocated as representing an efficient data-gathering scheme which can improve image signal-to-noise ratio. With such use, a medium field strength (0.5-1 T) is presented as representing, for general purpose imaging of head and torso, the best current compromise when imaging time is of major importance, with the important caveat that new techniques may always invalidate this conclusion.

Fourier Analysis↗

MR measurement of relative water content and multicomponent T2 relaxation in human breast.

MR techniques providing accurate measurement of relative volumetric water content and multicomponent T2 relaxation times from a large volume of interest, have been implemented for characterization of breast tissue in vivo. In a sequence of 20-s breath-holds, data are obtained from much of the breast volume while suppressing signal from the chest wall and torso. Relative water content of each breast is calculated from one-dimensional fat and water profiles obtained using a hybrid two-point Dixon method (TE/TR = 17/5000 ms). Multicomponent T2 relaxation measurements are calculated from T2 decay curves obtained using a CPMG train of rectangular pulses (TE/TR = 8/5000 ms, 140 echoes) preceded by saturation pulses to localize longitudinal magnetization spatially. These techniques, validated in phantoms and human volunteers, are suitable for quantitative study of breast tissue in vivo, and in particular to investigate the potential role of MR for assessment of breast cancer risk.

Body Water↗

Ultimate intrinsic signal-to-noise ratio in MRI.

A method to calculate the ultimate intrinsic signal-to-noise ratio (SNR) in a magnetic resonance experiment for a point inside an arbitrarily shaped object is presented. The ultimate intrinsic SNR is determined by body noise. A solution is obtained by optimizing the electromagnetic field to minimize total power deposition while maintaining a constant right-hand circularly polarized component of the magnetic field at the point of interest. A numerical approximation for the optimal field is found by assuming a superposition of a large number of plane waves. This simulation allowed estimation of the ultimate intrinsic SNR attainable in a human torso model. The performance of six coil configurations was evaluated by comparing the SNR of images obtained by the coils with the ultimate values. In addition, the behavior of ultimate intrinsic SNR was investigated as a function of main field strength. It was found that the ultimate intrinsic SNR increases better than linearly with the main magnetic field up to 10 T for our model. It was observed that for field strengths of 4 T or higher, focusing is required to reach the ultimate intrinsic SNR.

Abdomen↗

Large field-of-view real-time MRI with a 32-channel system.

The emergence of parallel MRI techniques and new applications for real-time interactive MRI underscores the need to evaluate performance gained by increasing the capability of MRI phased-array systems beyond the standard four to eight high-bandwidth channels. Therefore, to explore the advantages of highly parallel MRI a 32-channel 1.5 T MRI system and 32-element torso phased arrays were designed and constructed for real-time interactive MRI. The system was assembled from multiple synchronized scanner-receiver subsystems. Software was developed to coordinate across subsystems the real-time acquisition, reconstruction, and display of 32-channel images. Real-time, large field-of-view (FOV) body-survey imaging was performed using interleaved echo-planar and single-shot fast-spin-echo pulse sequences. A new method is demonstrated for augmenting parallel image acquisition by independently offsetting the frequency of different array elements (FASSET) to variably shift their FOV. When combined with conventional parallel imaging techniques, image acceleration factors of up to 4 were investigated. The use of a large number of coils allowed the FOV to be doubled in two dimensions during rapid imaging, with no degradation of imaging time or spatial resolution. The system provides a platform for evaluating the applications of many-channel real-time MRI, and for understanding the factors that optimize the choice of array size.

Abdomen↗

3D fluoroscopy with real-time 3D non-cartesian phased-array contrast-enhanced MRA.

For optimized CE-MRA of the chest and abdomen, the scan time and breath-hold must be coordinated with the arrival of contrast. A 3D fluoroscopy system is demonstrated that performs real-time 3D projection reconstruction acquisition, reconstruction, and visualization using only the standard scanner hardware and operator console workstation. Unlike 2D fluorotriggering techniques, no specification of a monitoring slab or careful placement of the imaging volume is required. 3DPR data are acquired continuously throughout the examination using an eight-channel receiver and 1 s interleaved subframes. The data are reconstructed using 1 s segments for real-time monitoring with 0.8-cm isotropic spatial resolution over the entire torso, allowing full-volume axial, coronal, and sagittal MIPs to be displayed simultaneously with minimal latency. The system later uses the same scan data to generate high-spatial-resolution time-resolved sequences of the breath-hold interval. The 3D fluoroscopy system was validated on phantoms and human volunteers.

Artifacts↗

Bayesian parallel imaging with edge-preserving priors.

Existing parallel MRI methods are limited by a fundamental trade-off in that suppressing noise introduces aliasing artifacts. Bayesian methods with an appropriately chosen image prior offer a promising alternative; however, previous methods with spatial priors assume that intensities vary smoothly over the entire image, resulting in blurred edges. Here we introduce an edge-preserving prior (EPP) that instead assumes that intensities are piecewise smooth, and propose a new approach to efficiently compute its Bayesian estimate. The estimation task is formulated as an optimization problem that requires a nonconvex objective function to be minimized in a space with thousands of dimensions. As a result, traditional continuous minimization methods cannot be applied. This optimization task is closely related to some problems in the field of computer vision for which discrete optimization methods have been developed in the last few years. We adapt these algorithms, which are based on graph cuts, to address our optimization problem. The results of several parallel imaging experiments on brain and torso regions performed under challenging conditions with high acceleration factors are shown and compared with the results of conventional sensitivity encoding (SENSE) methods. An empirical analysis indicates that the proposed method visually improves overall quality compared to conventional methods.

Algorithms↗

On restoring motion-induced signal loss in single-voxel magnetic resonance spectra.

Destructive interference from phase fluctuations caused by motion during (1)H magnetic resonance spectroscopy (MRS) stimulated-echo acquisition mode (STEAM) and point-resolved spectroscopy (PRESS) acquisitions can significantly diminish the traditional radicalN-gain in signal-to-noise ratio (SNR) afforded by averaging N signals, especially in the torso. The SNR loss is highly variable among individuals, even when identical acquisition protocols are used. This paper presents a theory for the SNR loss, assuming that the phase fluctuates randomly. It is shown that SNR in conventional averaging is reduced by the factor sinc(sigma(phi) radical3/pi), where sigma(phi) is the standard deviation (SD) of the phase. "Constructive averaging," whereby each individual acquisition is phase-corrected using the phase of a high-SNR peak before averaging, reverses the SNR loss from motion-induced dephasing, resulting in a {1/sinc(sigma(phi) radical3/pi)}-fold SNR improvement. It is also shown that basing phase corrections on an average of radicalN adjacent points both improves correction accuracy and effectively eliminates false signal artifacts when corrections are based on low-SNR peaks. The theory is validated over a sevenfold range of variation in signal loss due to motion observed in (1)H STEAM and PRESS data acquired from 17 human subjects (heart: N = 16; leg: N = 1). Constructive averaging should be incorporated as a routine tool for in vivo (1)H MRS.

Artifacts↗

Far-field potentials in circular volumes: the effect of different volume sizes and intercompartmental openings.

Preliminary investigations of circular volume conductors suggested that far-field potential magnitude declines progressively slower with increasing radial distance from a current source and follows a cosine function with angular displacement of the recording electrode from the electrical generator's axis. Using circular volumes of 6 differing radii, the mathematical relationship between angle, radii, and far-field potential amplitude is determined. Previous theoretical relationships of amplitude versus dipolar spacing, current, and distance from a dipole generator in a bounded volume conducting medium are verified for the near-field. Far-field potentials in circular volumes are found to become constant at radii greater than 75% of the bounded volume's radius. Additionally, an adjoining volume conductor acts simply as a passive fluid-filled electrode (wick electrode) to the circular volume containing the generator until the intercompartmental opening to the circular volume exceeds 20% of its circumference. This finding was clinically supported by recording similar P9 somatosensory-evoked far-field potentials generated caudal to the foramen magnum from various portions of the cranium, whose connections to the torso, foramen magnum, and neck, average 6.2% and 17.8%, respectively. Finally, 3 circular volume conductors were connected in series by channels less than 20% of the volume conductor's circumference. Both adjoining circular volumes were equipotential to the far-field potential present at the boundary of the first circular volume containing the dipole generator. This observation supports the clinical finding of far-field potential transmission through multiple human bodies in conductive contact.

Action Potentials↗

Healing determinants in older people with leg ulcers.

A descriptive correlational design was used to identify the physiologic, therapeutic, and psychosocial determinants of leg ulcer healing in community-residing older people with venous and venous-arterial disease (N = 156). A regression model with healing rate as the dependent variable explained 49% of the variance. Increased pain when mobilizing, increased hours with limbs horizontal to the torso, and moderate and severe liposclerosis (hardening and induration of the skin) were associated with poorer healing rates. Higher wound status scores were associated with more rapid healing rates. Self-efficacy beliefs and social support were not significant factors. The findings suggest the need for early detection and management of limb pain that interferes with normal mobility. Limb position and edema assessment prior to the application of compression bandages is recommended, with bandages that provide clients with high compression when ambulant and low compression when resting being potentially beneficial.

Aged↗

Influence of jacket tightness and pressure on raised lung volume forced expiratory maneuvers in infants.

While the use of the raised volume rapid thoraco-abdominal compression (RVRTC) technique has been shown to provide new insights into airway and pulmonary pathophysiology in infants, and appears to resemble the spirometric techniques used in older subjects, there is as yet no consensus regarding measurement procedures, which are known to vary considerably between laboratories (Gappa [1999] Pediatr Pulmonol 28:391-393). The aims of this study were to assess the effects of tightness of jacket fit, the efficiency with which pressure is transmitted from the jacket to the intrathoracic airways, and the effect of jacket pressure on parameters derived from the RVRTC technique. Paired forced expiratory maneuvers were performed in 20 infants with the jacket snugly or loosely wrapped around the infant's torso, and in a further 21 infants using "optimal" or a higher jacket pressure (P(j)) (1-2 kPa above "optimal" P(j)). When either a loosened jacket or a higher than "optimal" P(j) was used, forced expired flow at low lung volumes (FEF(75)) was significantly reduced by, on average, 8% and 7%, respectively. There were, however, minimal changes in forced vital capacity (FVC) or forced expired volume in 0.4 sec (FEV(0.4)). The observed changes may have been due to the increased pressure transmitted to the intrathoracic structures under these experimental conditions, and emphasize the need to assess optimal jacket pressure within each infant when using the RVRTC technique. In addition, when using a loosened jacket or a higher than "optimal" P(j), chest wall and upper airway reflexes such as glottic closure, peripheral airway closure, and negative flow dependence were more evident.

Confidence Intervals↗

The long-term effect of high-frequency chest compression therapy on pulmonary complications of cystic fibrosis.

A high-frequency chest compression (HFCC) device for clearance of mucous secretions from airways was tested in 16 cystic fibrosis (CF) patients with significant improvement in pulmonary function for the HFCC period, which averaged 22 months per patient. The device consists of a variable air pulse delivery system and a non-stretch inflatable vest worn by the patient to cover the entire torso. The patients perform 30 minute therapy sessions divided into 5 minute periods at each of six frequencies. Individual patient therapy time per day ranged from 30 to 240 minutes. Frequencies used by each patient were determined by measuring air flow at the mouth and calculated volume expired per chest compression during tidal breathing while receiving HFCC at frequencies between 5 and 22 Hz at 1 Hz increments. The frequencies that produced the three highest flows and the three largest volumes were selected for each patient's therapy. Ninety-four percent of patients' regression line slopes for percent predicted forced vital capacity (FVC) and forced expiratory volume in 1 second (FEV1) became more positive during self-administered HFCC therapy as compared to slopes before HFCC therapy, when manual chest physical therapy was used. Two-sided t-test showed that the mean slopes were more positive for FVC and FEV1 during HFCC therapy than for the manual chest physical therapy period before HFCC therapy. The significance level for both FVC and FEV1 was at P less than 0.001.

Adolescent↗

Breathing patterns and heart rate during simulated occupational upper limb tasks in normal subjects.

BACKGROUND AND PURPOSE: Despite the arms being used extensively in the performance of many occupational tasks, little is known about the pattern of breathing and physiological cost of such work. The purpose of this study was to establish whether a simple change in arm support could alter the workload, pattern of breathing and respiratory muscle recruitment during a low intensity arm task. METHODS: Ten normal subjects performed a simulated work task when sitting, once with the arms supported and once unsupported. Subjects were required, over a five-minute period, to repeatedly pick up a 2 kg object, inspect and hold it for 15 seconds and then pack it in a box. Breathing pattern responses, measured by pneumotachograph and respiratory inductive plethysmography, were minute ventilation (VE), respiratory frequency (Rf), tidal volume (VT) and change in functional residual capacity (FRC). RESULTS: The main findings were that unsupported arm work was more physiologically demanding than supported arm work. During work VE increased as a result of a change in respiratory frequency but not VT which was much more limited when the arms were unsupported. At the completion of activity, when the arms were unloaded, VT initially increased as VE decreased. FRC and VT were reduced during arm work and increased during recovery, mainly as a result of a change in ribcage excursion. CONCLUSIONS: These findings support the theory that during arms activity, intercostal and accessory respiratory muscles act to stabilize the arms and torso, impeding chest wall movement and shifting the respiratory load from these muscles to the diaphragm. This may adversely effect performance of workers who have ventilatory limits to arm work tasks.

Adolescent↗

Evaluation of a new norepinephrine transporter PET ligand in baboons, both in brain and peripheral organs.

Reboxetine is a specific norepinephrine transporter (NET) inhibitor and has been marketed in several countries as a racemic mixture of the (R,R) and (S,S) enantiomers for the treatment of depression. Its methyl analog (methylreboxetine, MRB) has been shown to be more potent than reboxetine itself. We developed a nine-step synthetic procedure to prepare the normethyl precursor, which was used to synthesize [11C]O-methylreboxetine ([11C]MRB). We also developed a convenient resolution method using a chiral HPLC column to resolve the racemic precursor to obtain enantiomerically pure individual precursors that lead to the individual enantiomers (R,R)-[11C]MRB and (S,S)-[11C]MRB. Here we report an evaluation of the racemate and individual enantiomers of [11C]MRB as radioligands for PET imaging studies of NET systems in baboons both in brain and in peripheral organs. The relative regional distribution of the radioactivity after injection of [11C]MRB in baboon brain is consistent with the known distribution of NET. For a NET-poor region such as striatum, there were no significant changes in the striatal uptakes with and without the nisoxetine pretreatment. In contrast, a significant blocking effect was observed in NET-rich regions such as thalamus and cerebellum after injection of racemic [11C]MRB, with an even more dramatic effect after injection of (S,S)-[11C]MRB. These results, along with the fact that there was no regional specificity and no blocking effect by nisoxetine for (R,R)-[11C]MRB, suggest the enantioselectivity of MRB in vivo, consistent with previous in vitro and in vivo studies in rodents. PET studies of baboon torso revealed a blocking effect by desipramine only in the heart, a NET-rich organ, after injection of (S,S)-[11C]MRB, but not the (R,R)-isomer. These studies demonstrate that the use of (S,S)-[11C]MRB would allow a better understanding of the role that NET plays in living systems.

Animals↗

Constructing a 3-D mesh model for electrical cardiac activity simulation.

The 3-D ventricle model in this study was reconstructed from a series of MRI torso cross-section data. We used a 3-D voxel array to represent the ventricle. As in cardiac simulations proposed by previous studies, the activation sequence and body surface ECG were simulated in this model. But to reduce the amount of elements in the model, so that the amount of parameters in the model can be handled numerically, we propose another approach to simulate cardiac activity. A mesh model was constructed on the closed surface formed by epicardiac and endocardiac surfaces of the ventricle. We propose a method to simulate the activation sequence on the epicardiac and endocardiac surfaces of the mesh model. As with the uniform double layer theorem, body surface ECG can be estimated in terms of epicardiac and endocardiac surface current source. Consequently, we can also generate ECG waveforms corresponding to this mesh simulation. Both the depolarization sequence and ECG simulated by the mesh model resemble those generated by the 3-D voxel model. However, the mesh model greatly simplified the process of ECG simulation. Both the simulation of depolarization and ECG estimation were expressed in terms of clear and simple mathematical representations. Consequently, we can analytically investigate the effects of the mesh model's parameters on the cardiac activation sequence and ECG. It could be a useful tool to numerically study the relation of ECG waveforms and electrical activity of the heart.

Computer Simulation↗

The nonreceptor protein tyrosine phosphatase corkscrew functions in multiple receptor tyrosine kinase pathways in Drosophila.

Corkscrew (csw) encodes a nonreceptor protein tyrosine phosphatase (PTPase) that has been implicated in signaling from the Torso receptor tyrosine kinase (RTK). csw mutations, unlike tor mutations, are associated with zygotic lethality, indicating that Csw plays additional roles during development. We have conducted a detailed phenotypic analysis of csw mutations to identify these additional functions of Csw. Our results indicate that Csw operates positively downstream of other Drosophila RTKs such as the Drosophila epidermal growth factor receptor (DER), the fibroblast growth factor receptor (Breathless), and likely other RTKs. This model is substantiated by specific dosage interactions between csw and DER. It is proposed that Csw is part of the evolutionarily conserved "signaling cassette" that operates downstream of all RTKs. In support of this hypothesis, we demonstrate that SHP-2, a vertebrate PTPase similar to Csw and previously implicated in RTK signaling, encodes the functional vertebrate homologue of Csw.

Alleles↗

Quantitative variations in the level of MAPK activity control patterning of the embryonic termini in Drosophila.

We have examined the role in patterning of quantitative variations of MAPK activity in signaling from the Drosophila Torso (Tor) receptor tyrosine kinase (RTK). Activation of Tor at the embryonic termini leads to differential expression of the genes tailless and huckebein. We demonstrate, using a series of mutations in the signal transducers Corkscrew/SHP-2 and D-Raf, that quantitative variations in the magnitude of MAPK activity trigger both qualitatively and quantitatively distinct transcriptional responses. We also demonstrate that two chimeric receptors, Torextracellular-Egfrcytoplasmic and Torextracellular-Sevcytoplasmic, cannot fully functionally replace the wild-type Tor receptor, revealing that the precise activation of MAPK involves not only the number of activated RTK molecules but also the magnitude of the signal generated by the RTK cytoplasmic domain. Altogether, our results illustrate how a gradient of MAPK activity controls differential gene expression and, thus, the establishment of various cell fates. We discuss the roles of quantitative mechanisms in defining RTK specificity.

Animals↗

Adaptation to Coriolis force perturbation of movement trajectory; role of proprioceptive and cutaneous somatosensory feedback.

Subjects exposed to constant velocity rotation in a large fully-enclosed room that rotates initially make large reaching errors in pointing to targets. The paths and endpoints of their reaches are deviated in the direction of the transient lateral Coriolis forces generated by the forward velocity of their reaches. With additional reaches, subjects soon reach in straighter paths and become more accurate at landing on target even in the absence of visual feedback about their movements. Two factors contribute to this adaptation: first, muscle spindle and golgi tendon organ feedback interpreted in relation to efferent commands provide information about movement trajectory, and second, somatosensory stimulation of the fingertip at the completion of a reach provides information about the location of the fingertip relative to the torso.

Acceleration↗