Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Torque”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49Linked to original sources

Formation and control of optimal trajectory in human multijoint arm movement. Minimum torque-change model.

In this paper, we study trajectory planning and control in voluntary, human arm movements. When a hand is moved to a target, the central nervous system must select one specific trajectory among an infinite number of possible trajectories that lead to the target position. First, we discuss what criterion is adopted for trajectory determination. Several researchers measured the hand trajectories of skilled movements and found common invariant features. For example, when moving the hand between a pair of targets, subjects tended to generate roughly straight hand paths with bell-shaped speed profiles. On the basis of these observations and dynamic optimization theory, we propose a mathematical model which accounts for formation of hand trajectories. This model is formulated by defining an objective function, a measure of performance for any possible movement: square of the rate of change of torque integrated over the entire movement. That is, the objective function CT is defined as follows: (formula; see text) We overcome this difficult by developing an iterative scheme, with which the optimal trajectory and the associated motor command are simultaneously computed. To evaluate our model, human hand trajectories were experimentally measured under various behavioral situations. These results supported the idea that the human hand trajectory is planned and controlled in accordance with the minimum torque-change criterion.

Arm↗

Relationship of triceps surae torques to photographed tibia-calcaneum angles in man (II).

A previous paper described an apparatus and method for giving the relationship between triceps surae torque and the tibia-calcaneum angle. As a first approximation we took the angle between the calcaneum and the foot-plate as being invariable in all subjects, when the torque was zero. The aim of the present work is to measure the inter-individual variations of the angle. 1. Guide-marks are selected on the skin; showing the axes of the calcaneum and of the leg. Metal rods indicate the axes thus defined and the true angle between the leg and the calcaneum is measured by photography. The curves drawn from these true angles differ from the preceding curves by 0 degrees to 10 degrees for normal children and +12 degrees to -15 degrees for cerebral palsied children. 2. The photographic method verifies the exactitude of the trigonometrical method of correcting angles that we proposed in the previous paper.

Ankle Joint↗

An apparatus and a method for measuring the relationship of triceps surae torques to tibio-tarsal angles in man.

1. The apparatus and method described give the relationship of triceps surae torque to the absolute tibio-tarsal angle. Data of the anatomy of the foot and the axis of the ankle are taken into consideration. They make complementary measurements necessary, which in certain cases enable the angle recorded by the apparatus to be corrected so as to obtain the true angle. 2. The reliability of the apparatus and the technique of linkage of subject to apparatus are judged by examination of the torque-angle plots obtained by passive stretching of the triceps in 7 subjects for whom correction is monor. Good reliability was observed during the session and from one session to another. The plot is exponential. The merits of the method of correcting angles are illustrated in three subjects with the same protocol: when plots are not corrected, they are more dispersed during the session and no longer exponential. These results justify the considerable correction of the angle that we propose in the study of isometric contractions.

Adult↗

Muscle cross-sectional area and torque in resistance-trained subjects.

Eight elite male bodybuilders (MB), five elite female bodybuilders (FB), eight male control (MC), and eight female control recreational weight-trainers (FC) performed maximal elbow flexions on an isokinetic dynamometer at velocities between 1.02 and 5.24 rad.s-1, from which peak torque (PT) was measured. Elbow flexor cross-sectional area (CSA) was measured by computed tomographic scanning. Flexor CSA.lean body mass-1 ratios were greater in MB than in other subject groups. Correlations of PT were positively related to CSA but negatively to CSA.lean body mass-1 and to PT.CSA-1. PT.CSA-1 at low-velocity contractions were greater in MC and FC than in MB and FB groups, suggesting a training effect. The velocity-associated declines in torque between velocities of 1.02 and 5.24 rad.s-1 averaged 28.4 +/- 0.9% and were statistically identical in men and women among the subject groups, suggesting that neither gender nor training had affected this variable.

Female↗

Maximum isokinetic ankle plantar and dorsal flexion torques in trained subjects.

Isokinetic ankle plantar- and dorsal-flexion torques, IPF and IDF, respectively, were measured in twenty-five physically healthy athletes, fifteen males and ten females, with simultaneous recording of rectified, linearly enveloped surface electromyograms, and peak electromyographic tensions (PEMG). Angular delays from the start of motion to occurrence of peak torques were also registered. Manoeuvres were performed in two knee positions. For comparison of strength 30 non-athletic (untrained) controls were included. IPF, but not IDF, was greater in the trained than in the untrained subjects. Formulae for estimation of IPF at 30 degrees differ between trained and untrained subjects. Smaller gender differences in maximum strength for trained than for untrained subjects suggest that habitual rather than genetic dissimilarities cause sex differences in strength. Slope differences in the negative exponential models which characterize IPF and IDF as functions of increasing velocity of angular motion may be caused by different structural properties of ankle flexors and extensors. A lower PEMG of the m. gastrocnemius in the flexed than in the extended knee positions can explain the lower IPFs, suggesting that mechanical rather than supraspinal factors cause postural IPF differences. In contrast, greater IDF in the flexed than in the extended knee positions may indicate that neurogenic mechanisms are involved.

Adult↗

Bilateral eccentric and concentric torque of quadriceps and hamstring muscles in females and males.

This study assessed maximum eccentric (ECC) and concentric (CON) torque of quadriceps (QUAD) and hamstring (HAM) muscle groups in healthy females (n = 13) and males (n = 27). Peak torques (PT) of bilateral muscle actions were recorded at constant angular velocities of 0.52, 1.57 and 2.61 rad.s-1. The QUADCON and HAMCON PT decreased (p less than 0.05) with increasing angular velocity. The QUADECC and HAMECC PT increased (p less than 0.05) in females, whereas QUADECC PT decreased (p less than 0.05) and HAMECC PT showed no change in males. In general, ECC PT was higher (p less than 0.05) than CON PT and QUAD PT was higher (p less than 0.05) than HAM PT, for any given angular velocity. Males displayed higher (p less than 0.05) PT than females but when PT were adjusted for body mass the sex differences in QUADCON and HAMCON were reduced (p less than 0.05), whereas the differences in QUADECC and HAMECC were abolished. The CON and ECC PT were, on average, 60% and 41% greater, respectively, in males than in females. The corresponding differences, when adjusted for body mass, were 23% and 8%. ECC:CON PT for QUAD were higher (p less than 0.05) in females than in males. CON and ECC HAM:QUAD PT ratio increased (p less than 0.05), as a function of velocity. This study suggests, that bilateral ECC PT is higher than CON PT and CON HAM:QUAD PT ratio is higher than ECC HAM:QUAD PT ratio.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Force measurement and design of a torquing high-pull headgear.

The dynamic extraoral force analyzer (DEFA) was found to be capable of measuring linear deflection as a function of force created by a headgear. Ten standard nontorqued face-bows with a cervical and a high-pull direction were tested to determine the reliability of the DEFA. Statistical analysis showed the DEFA to be reliable and accurate in differentiating various directions and deflections of maxillary molars. Doubled-over distal ends of the inner bow with 0 degree of torque and a parietal direction of pull were used as controls. The same face-bows with 9 degrees of buccal root torque were tested on the DEFA. These face-bows were tested to determine whether transverse translation without buccal crown tipping of the maxillary first molar will occur. Statistical analysis showed that transverse translation occurred at a force of 200 to 347 gm.

Dental Stress Analysis↗

Reaction torques and operator stress while using powered nutrunners.

Reaction torque measures of six different nutrunners were correlated with EMG measures and subjective ratings of perceived exertion for different work surface orientations, joint stiffnesses, rpm levels, air pressure levels and handle configurations. Using an underpowered tool or using a softer joint resulted in larger impulses and worse ratings. A pulse-type shut-off mechanism produced the lowest reaction torque and the best rating. Overall, ratings correlated directly with the impulse level. The subjects were good judges of stress levels, and subjective ratings were valid measures of operators stress.

Journal Article↗

Dynamics of human ankle stiffness: variation with mean ankle torque.

The left foot of five human subjects was rotated in a fixed stochastic pattern about a constant ankle angle and the forces opposing these perturbations were measured. The dynamic stiffness transfer functions relating ankle angular position to ankle torque were calculated. Stiffness gain was flat at low frequencies, had a resonant valley at intermediate frequencies and rose at about 40 dB/decade at high frequencies. The low frequency gain and resonant frequency increased progressively with increases in tonic muscular activity. The dynamic stiffness of the ankle was well described by a linear, under-damped, second-order transfer function having inertial, viscous and elastic terms. Estimates of the inertial parameter were independent of the level of muscle activity whereas the viscous and elastic parameters increased with increases in mean torque level.

Adult↗

A dynamometer for the measurement of the extension torque of the lower leg during static and dynamic contractions of the quadriceps femoris muscle.

A dynamometer which makes an angular movement is described. The dynamometer enables the measurement of the extension torque of the lower leg at different knee angles during static and slow concentric and eccentric contractions of the quadriceps femoris muscle. The influence of gravity on the measured torque signal can be compensated for by another signal representing the angular movement. The application of the dynamometer is demonstrated by giving an example of measurement.

Biomechanical Phenomena↗

A biomechanical model for flexion torques of human arm muscles as a function of elbow angle.

The contribution that a muscle makes to a torque in a certain direction depends among other things on the length and on the mechanical advantage of the muscle. In this study a simple model is presented which enables us to calculate the torques exerted by elbow flexor muscles as a function of elbow angle. The model is tested and verified with a method of spike triggered averaging.

Adult↗

Investigation of the torque-tension characteristics of a flanged external fixator pin.

The torque-tension characteristics of standard, conical and flanged external fixator pins and a cortical screw were compared using a commercially available testing apparatus. The flanged pin and the screw were similar in behaviour, and converted torque into tension more efficiently than conical and standard external fixator pins.

Biomechanical Phenomena↗

Comparison of torque measurements between cortical screws and emergency replacement screws in the cadaver mandible.

The so-called emergency screws are designed for use in a drill hole where the conventional screw has failed following a stripped bone thread. It is not known, however, if these screws are as well anchored in bone as cortical screws, nor is it known how well they secure contact to the previously damaged screw bed. On the basis of torque measurements in mandibles of fresh cadavers, emergency screws were compared with cortical screws. Further, the contact between emergency screw and bone was investigated on interfacial sections after embedding in methyl methacrylate resin. The maximum torque reached during insertion of the AO emergency screws was about 70% of the value measured with 2.7-mm conventional cortical screws and 67% of this value when the 3.2-mm emergency screws were used. While the emergency screws had good contact to the bone in the thread crest area, no bone contact was evident at the bottom of thread groove. This experimental situation can not be entirely extrapolated to the clinical situation. However, the study seems to suggest that emergency screws do not fully meet the demands of rigid internal fixation.

Adolescent↗

Labial root torque: effect on the maxilla and incisor root apex.

This study was designed to determine the effectiveness of labial root torque on anterior nasomaxillary development. Quantification was made of the angular and linear changes in Downs' point A (representing midsagittal basal bone) and incisor point A (representing the dentoalveolar bone) and any concomitant incisor root resorption. The study was divided into two parts: part 1--to determine the anatomic configuration of the premaxillary region by use of laminagraphy on skulls, and part 2--to use the morphologic landmarks found in part 1 to assess the development of the nasomaxillary complex in maxillary retrusive patients. The clinical study involved 17 maxillary retrusive patients, aged 8.0 to 15.7 years, who had been treated for a period between 0.31 and 3.70 years with edgewise advancing mechanics. Clinical results indicate that during the first phase of orthodontic treatment with labial root torque, encompassing a 0.63-year mean treatment period, a greater rate of advancement of Downs' point A was produced when compared with normal growth. The skeletal convexity increased, whereas normal growth straightened the profile. Incisor point A advanced at a greater rate than Downs' point A, suggesting that treatment caused a larger dentoalveolar effect than the effect on midsagittal basal bone. When treatment was extended to 1.57 years, similar changes were found but at a reduced rate. Overall apical root resorption was 12.7%/year. Sex and age were not found to have any correlation to the amount of apical root loss.

Cephalometry↗

The effect of using a laptopstation compared to using a standard laptop PC on the cervical spine torque, perceived strain and productivity.

The objective of this study was to assess the effect of using a laptopstation and a laptop PC and how this difference in work set-up affected the mechanical load on the neck (C7-Th1 segment), the subjective evaluation of strain on the neck and productivity. Ten healthy male students at Umeå University, Sweden with an average of 10 years of PC work experience and an average of 18 months of laptop PC work experience participated in the study. For each research subject measurements were divided into two parts; sitting working at the ErgoQ laptopstation in test situation A, and sitting working at a conventional laptop PC, test situation B. Each part took 4h and was scheduled on two consecutive days. Photography and biomechanical analysis was used to calculate the torque at the neck. To examine perceived strain the Borg Scale was used and to assess performance a productivity score was calculated. The results in the study demonstrated a significant (p<0.05) difference with the use of the laptopstation resulting in decreased torque at the C7-Th1 segment, less perceived strain at the neck and a higher productivity score. In conclusion, the results of the study confirm the importance of adjustable work tools that recognize anthropometric differences and biomechanics to meet the needs of individual customers during continuous visual display terminal work.

Adult↗

Effects of a postoperative resistive exercise program on the knee extension and flexion torque in children with cerebral palsy: a randomized clinical trial.

OBJECTIVE: To investigate the effects of resistive exercise on the knee extension and flexion torque production during the rehabilitation period after multilevel orthopedic surgery. DESIGN: Randomized clinical trial. SETTING: Hospital rehabilitation department. PARTICIPANTS: Thirty-nine children with spastic diplegic cerebral palsy (CP) (age range, 6-16 y), randomly allocated to an exercise group (n=19) and a control group (n=20). All received conventional physiotherapy (PT), and the exercise group also followed a resistive exercise program. INTERVENTION: A 9-month standardized home-based resistive exercise program, which started about 3 months after the surgery. MAIN OUTCOME MEASURES: The Gross Motor Functional Measurement (GMFM) assessed before (E(0)) and 1 year (E(1)) after the surgery. The Modified Ashworth Scale and the isometric and isokinetic torque of the knee extensors and flexors were evaluated at E(0), E(1), and 6 months after the surgery. RESULTS: The knee extension and flexion moments had decreased 6 months after the surgery and recovered to the preoperative level 1 year after surgery. These changes were not group dependent. CONCLUSIONS: Additional long-term, home-based, low-cost resistive exercise that starts soon after the operation of patients with CP was not more beneficial than conventional PT only, in terms of strength and GMFM.

Adolescent↗

Torque measurements of the mechanical load capacity of thin bony structures of the visceral cranium.

The stability of self-tapping screws of the Luhr (1979)-mini-plate system in thin facial bones was assessed. The maximal possible torque which can be applied to the screws before they strip the thread in the bone was measured. This end point was called the penetration torque. Only the central section of the maxillary sinus wall was unsuitable for anchorage of the screw and plate. The other sections of the osseous middle and lateral parts of the face, of the glabella and of the root of the nose have sufficient strength for bony segments to be anchored using plates.

Adult↗

Study of effect of excipient source variation on rheological behavior of diltiazem HCl-HPMC wet masses using a mixer torque rheometer.

In the wet massing of powders and powder blends, the rheological behavior of the wet powder masses not only plays a critical role in the unit process but also influences the attributes of the product. The physical properties of the powder excipients, such as particle size and size distribution, shape, surface area, bulk and tapped density and surface morphology, are a major source of variability in the rheological behavior of wet powder masses and the quality attributes of the final product. The objective of the present investigations was to study the rheological behavior of wet masses containing hydroxypropyl methylcellulose (HPMC) obtained from two sources (Methocel from Dow and Pharmacoat from Shin-Etsu) using a mixer torque rheometer. In order to simulate a real formulation, diltiazem HCl (DTZ) (40% loading) was used as part of the substrate powder mass. Hydroxypropyl cellulose (HPC) was used as the binder. Since HPMC is water-soluble, isopropyl alcohol (IPA) was used as the wet massing liquid. The rheological behavior of the wet powder masses was studied as a function of mixing time and amount of wet massing liquid (IPA). The rheological profiles obtained for DTZ-Methocel and DTZ-Pharmacoat exhibited same magnitude for mean torque, however, for DTZ-Pharmacoat the peak was more extended than that for DTZ-Methocel. The extended peak for DTZ-Pharmacoat indicated that the wet mass will stay suitable during the process for larger quantities of the wet massing liquid before turning into paste and becoming unsuitable for the process as compared with the DTZ-Methocel system. The mixing kinetics of the two powder systems appeared to be quite different. These differences in the rheological behavior of the wet masses may be attributed to the difference in the particulate and surface properties of the two HPMCs. Some of the properties of the two HPMCs, such as particle size and size distribution, surface area, surface morphology and DSC thermograms, explain the difference observed in their rheological behavior. The difference in the rheological profiles of the two DTZ-HPMC systems indicated superiority of Pharmacoat over Methocel considering their wet massing behavior.

Calorimetry, Differential Scanning↗