Rest-injected thallium-201 redistribution and resting technetium-99m methoxyisobutylisonitrile uptake in coronary artery disease: relation to the severity of coronary artery stenosis.

To compare rest-injected thallium-201 (Tl) redistribution and resting technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) myocardial uptake in chronic coronary artery disease (CAD), 15 patients with angiographically proven CAD and left ventricular (LV) dysfunction (ejection fraction 34% +/- 9%) were studied. All patients underwent rest-redistribution Tl and resting 99mTc-MIBI cardiac imaging. Gated 99mTc-MIBI images were also acquired to assess regional LV wall motion (WM). Myocardial segments (n = 225) were divided into three groups on the basis of the degree of coronary artery stenosis: group 1 (total occlusion, n = 82), group 2 (50%-99% of stenosis, n = 84) and group 3 (< 50% of stenosis, n = 59). WM was significantly worse in groups 1 and 2 compared to group 3 (P < 0.001), but no difference was observed between groups 1 and 2. Tl and 99mTc-MIBI uptake were significantly lower in groups 1 and 2 compared to group 3 (P < 0.001), and in group 1 compared to group 2 (P < 0.001). When Tl and 99mTc-MIBI uptake were directly compared. Tl uptake was higher than 99mTc-MIBI uptake in group 1 (P < 0.001), while no significant difference was observed in groups 2 and 3. Thus, both rest-injected Tl redistribution and resting 99mTc-MIBI uptake reflected the severity of coronary artery stenosis in CAD. However, in myocardial segments with total coronary occlusion Tl uptake was significantly higher than 99mTc-MIBI uptake.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Poor-quality red blood cell labelling with technetium-99m: case report and review of the literature.

Technetium-99m red blood cell (RBC) venography is a simple and sensitive technique for the diagnosis of deep vein thrombosis of the lower limb, but optimal labelling of the blood pool is essential for a diagnostic study. Here we report the case of a 44-year-old male with deep vein thrombosis of the right leg. RBC venography of the lower extremities showed poor labelling. In addition we review the literature on the subject.

Erythrocytes↗

Imaging rheumatoid arthritis joints with technetium-99m labelled specific anti-CD4- and non-specific monoclonal antibodies.

A direct comparison of the joint-imaging properties of inflammation-specific- and non-specific monoclonal antibodies (Mabs) was possible in a patient suffering from long-standing, severe rheumatoid arthritis (RA). This patient received an anti-CD4- and an anticarcinoembryonic antigen (anti-CEA) Mab, both labelled with technetium-99m, 9 days apart from each other. The anti-CD4 Mab was superior to the isotype-matched anti-CEA Mab in imaging inflamed joints. In the knee joint, the target-to-background ratio of the synovial membrane (SM) activity in comparison to that of adjacent large vessels was 1.22 (SM/muscle 1.55) for the anti-CD4 Mab and 0.53 (SM/muscle 0.92) for the anti-CEA Mab, in both cases 4 h after injection of the immunoglobulin. Since the CD4 antigen is present on the surface of T-helper lymphocytes and macrophages infiltrating the inflamed synovial membrane, imaging with the anti-CD4 Mab may allow more specific detection of inflammatory infiltrates in RA.

Aged↗

Motor stimulation response by technetium-99m hexamethylpropylene amine oxime split-dose method and single photon emission tomography.

We applied the technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) split-dose method in order to evaluate the feasibility of assessing cerebral blood flow (CBF) changes with single photon emission tomography (SPET) during a motor activation task. Eleven normal subjects were studied using the Tomomatic 564 (Medimatic, DK). Five subjects were studied twice at rest and 6 subjects at rest and during a motor task performance (finger opposition movements). A total of 28 mCi of 99mTc-HMPAO was injected in 2 doses with a 1:3 ratio. The first scan was obtained after injection of 7 mCi at rest in all subjects. The second scan was obtained a few minutes later, after injection of the remaining dose (21 mCi), under similar resting conditions or during a motor task performance. The mean brain uptake was proportional to the amount of tracer injected and to the acquisition time for both the first scan (5263 +/- 1266 counts x mCi x min) and the second (5034.4 +/- 966 counts x mCi x min). The grey/white matter ratio was 1.67 +/- 0.019 and 1.67 +/- 0.097 for the two scans, respectively. A three-way analysis of variance (ANOVA) for repeated measure showed no significant effects of side, slice and region of interest (ROI) on the CBF in the 5 subjects studied twice at rest, and the mean regional CBF change was -0.2% +/- 5%.(ABSTRACT TRUNCATED AT 250 WORDS)

Brain↗

The use of technetium-99m hexamethylpropylene amine oxime labelled white blood cells to detect subclinical inflammation of the heart after cardiopulmonary bypass in children with congenital heart disease.

Ten children (6 boys and 4 girls, aged 1-9 years old) underwent operations with a cardiopulmonary bypass, and the technetium-99m hexamethylpropylene amine oxine (99mTc-HMPAO) labelled white blood cell (WBC) heart scans were used to detect postoperative leukocyte infiltration in the hearts. The results showed that 80% (8/10) of the cases had subclinical inflammation in the hearts (grading of WBC scans > or = score 2), and a positive correlation (R = 0.77) was noted between the severity of the inflammation (grading of the WBC scans) and the duration of the cardiopulmonary bypass in the operations. Another control group (9 boys and 2 girls, aged 2-13 years old) underwent operations without a cardiopulmonary bypass, and subclinical inflammation of hearts was demonstrated in only 1 case (9%) by the 99mTc-HMPAO labelled WBC scans (grading of WBC scans < score 2) after the operations. There was a significant difference (P < 0.001, by a Wilcoxon rank sum test) based upon the severity of the ischaemic heart damage in the two groups. In our preliminary conclusions, the 99mTc-HMPAO labelled WBC heart scans may provide non-invasive and directly discernible evidence of subclinical inflammation in the heart due to a transient ischaemic state during a cardiopulmonary bypass, even if the clinical symptoms and signs of carditis are not apparent.

Cardiopulmonary Bypass↗

Comparison of stress-only vs. stress/rest with technetium-99m methoxyisobutylisonitrile myocardial perfusion imaging.

Unlike conventional thallium-201 myocardial imaging, technetium-99m methoxyisobutylisonitrile (MIBI) requires separate stress and rest injections. We prospectively studied 148 consecutive patients referred for myocardial perfusion studies to determine the diagnostic value of rest images once normal exercise or dipyridamole tomographic images had been obtained. In patients referred with no history of previous myocardial infarction in whom the diagnosis of coronary artery disease was suspected, 45 of 109 (41%) patients had normal stress tomographic images. Obtaining rest images did not alter the final interpretation in any of these cases. From this we infer that in patients with normal images after exercise or dipyridamole administration and no past history of myocardial infarction, 99mTc-MIBI rest images are not required. This provides several advantages including increased speed of diagnosis, decreased patient radiation exposure, improved cost efficiency and decreased demand on tomographic camera time.

Contrast Media↗

A comparative technetium 99m hexamethylpropylene amine oxime SPET study in different types of dementia.

Regional cerebral perfusion was evaluated by single photon emission computed tomography (SPET) using technetium 99m hexamethylpropylene amine oxime (99mTc-HMPAO) as a tracer, in 13 control subjects and 44 age-matched patients suffering from dementia of the Alzheimer's type (DAT, n = 19), presumed Pick's disease (n = 5), idiopathic Parkinson's disease with dementia (DPD, n = 15) and progressive supranuclear palsy (PSP, n = 5). HMPAO uptake was measured in the superior frontal, inferior frontal, parietal, temporal and occipital cortices, and the perfusion values were expressed as cortical/cerebellar activity ratios. As compared with controls, tracer uptake ratios in the DAT group were significantly reduced over all cortical regions, with the largest defects in the parieto-temporal and superior frontal cortices. A marked hypoperfusion affecting the superior and inferior frontal cortices was found in Pick's disease, whereas a mild but significant hypoperfusion was observed only in the superior frontal cortex of patients with PSP. In the DPD group, HMPAO uptake was significantly reduced in the parietal, temporal and occipital cortices, but not in the frontal cortex. These results show that DAT and DPD share an opposite anteroposterior HMPAO uptake defect as compared with the Pick's and PSP groups.

Aged↗

Estimation of technetium 99m mercaptoacetyltriglycine plasma clearance by use of one single plasma sample.

Recent studies have shown that technetium 99m mercaptoacetyltriglycine (MAG-3) is a suitable replacement for iodine 131 or 123 hippurate in gamma-camera renography. Also, the determination of its clearance is of value, since it correlates well with that of hippurate and thus may be an indirect measure of renal plasma flow. In order to simplify the clearance method we developed formulas for the estimation of plasma clearance of MAG-3 based on a single plasma sample and compared them with the multiple sample method based on 7 plasma samples. The correlation to effective renal plasma flow (ERPF) (according to Tauxe's method, using iodine 123 hippurate), which ranged from 75 to 654 ml/min per 1.73 m2, was determined in these patients. Using the developed regression equations the error of estimate for the simplified clearance method was acceptably low (18-14 ml/min), when the single plasma sample was taken 44-64 min post-injection. Formulas for different sampling times at 44, 48, 52, 56, 60 and 64 min are given, and we recommend 60 min as optimal, with an error of estimate of 15.5 ml/min. The correlation between the MAG-3 clearances and ERPF was high (r = 0.90). Since normal values for MAG-3 clearance are not yet available, transformation to estimated ERPF values by the regression equation (ERPF = 1.86 x CMAG-3 + 4.6) could be of clinical value in order to compare it with the normal values for ERPF given in the literature.

Humans↗

A modified technetium-99m isotope test to measure nasal mucociliary transport: comparison with the saccharine-dye test.

In this study two indirect mucociliary transport tests were compared. Nine subjects underwent duplicate saccharine-dye tests and duplicate modified technetium-99m (99mTc) tests, in which the radioactive 99mTc was nebulized in the nostril by means of a pump spray. The efficacy of mucociliary transport was deduced from the transport time of saccharine, dye and 99mTc. Transport rate also provided additional information in the 99mTc test. Transport rate correlated best in the repeated tests (r = 0.46), but was not significant (P = 0.21). Use of a pump spray for the 99mTc test instead of placement of a single droplet on the nasal mucosa makes the test easier to perform.

Adult↗

Technetium-99m hexamethyl propylene amine oxine leucocytes in the assessment of disease activity in inflammatory bowel disease.

The inflammatory activity in 108 bowel segments of 40 patients with suspected or known inflammatory bowel disease was assessed macroscopically by endoscopy, histology and technetium-99m hexamethyl propylene amine oxine (99mTc-HMPAO) leucocytes using a numerical grading system (scores 0-3). A 4-h series of scintigrams showed a significant correlation with both histological and macroscopical assessment of disease activity (rho = 0.850, P less than 0.001 and rho = 0.773, P less than 0.001, respectively). Sensitivity, specificity and accuracy of scintigraphy in detecting active inflammatory segments were 85%, 92% and 89%, respectively. A normal scintigram did not completely exclude mild inflammatory activity, especially in the rectosigmoid area. 99mTc-HMPAO leucocytes offer an accurate and non-invasive alternative for the assessment of disease activity in ulcerative colitis and Crohn's disease.

Adult↗

Anomalies in reduction-mediated technetium-99m labelling of monoclonal antibodies.

A reduction-mediated technetium-99m labelling method has been evaluated with a range of tumour-specific monoclonal antibodies. Antibodies reduced with 2-mercaptoethanol (2-ME) had free sulphydryl groups, but their number was much higher than could be accounted for by only limited intra-chain reduction of disulphide bonds. Reduced antibody could be labelled efficiently with 99mTc using an methylene diphosphonate (MDP) bone-scanning kit, although this seemed to depend on the presence of residual 2-ME in the preparations. With a carcinoembryonic antigen (CEA)-specific antibody, immunoreactivity of labelled antibody was confirmed, and after injection into nude with CEA-producing xenografts there was localisation into the tumours. Sephacryl S300 gel filtration showed the radiolabel eluting at a single discrete peak at the expected 150 kDa. However, examination of all of the labelled antibodies by polyacrylamide gel electrophoresis (PAGE) and autoradiography showed the presence of a large number of radiolabelled low molecular weight degradation products of the antibodies. These degradation products seemed to be formed in previously reduced antibodies during processing for PAGE, indicating some fragility of the reduced antibody.

Antibodies, Monoclonal↗

Radioimmunoimaging of subacute infective endocarditis using a technetium-99m monoclonal granulocyte-specific antibody.

Immunoscintigraphy with a technetium-99m murine monoclonal IgG1 antibody directed against non-specific cross-reacting antigen (NCA-95) and carcinoembryonic antigen was performed with 20 patients with suspected subacute infective endocarditis (SIE) and 6 controls with suspected inflammatory/infectious disease elsewhere in the body. Immunoscintigraphy and echocardiography localised SIE in 11 of 15 patients in whom the disease could be confirmed. In 4 patients with validated SIE, the immunoscan was abnormal, and the echocardiogram was normal. In another 4 patients, the result was exactly the opposite. These findings suggest that the combination of immunoscintigraphy and echocardiography improves diagnostic efficacy in patients with suspected SIE.

Adolescent↗

Increment of brain temporal perfusion during auditory stimulation. Preliminary study with technetium-99m HMPAO SPET.

A study on the dynamic exploration of the auditory pathway is presented, in which technetium-99m hexamethylpropylene amine oxime single-photon emission computed tomography (SPET) was used in volunteers with normal hearing. Changes in 99mTc-HMPAO distribution were calculated using a region of interest/whole-brain count ratio. The results showed a temporal perfusion increment of 17% (right) and 19% (left) during tonal supraliminar stimulation, which was significantly different from the control ROI. Sensitivity tests for the method were requested before any clinical application.

Acoustic Stimulation↗

First experience in healthy volunteers with technetium-99m L,L-ethylenedicysteine, a new renal imaging agent.

Animal studies have indicated that technetium-99m L,L-ethylenedicysteine (99mTc-L,L-EC) may be a promising tracer agent for renal function studies. We have performed a paired study with 99mTc-mercaptoacetyltriglycine (99mTc-MAG3) and 99mTc-L,L-EC in six male volunteers. In both cases, iodine-131-labelled o-iodohippurate was co-injected as an internal biological standard. The analog images between 0 and 30 min p.i. were of identical diagnostic value for both tracer agents. The two renograms were similar in all volunteers. The mean 1-h plasma clearance for 99mTc-MAG3 and 99mTc-L,L-EC was significantly different, respectively 382.9 +/- 17.1 ml/min per 1.73 m2 versus 460.2 +/- 47.7 ml/min per 1.73 m2 (P < 0.003). The urinary excretion after 30 min p.i. was 69.4% +/- 5.6% of the injected dose for 99mTc-MAG3 versus 66.5% +/- 2.5% for 99mTc-L,L-EC (P > 0.05) and after 60 min p.i. respectively 83.1% +/- 3.9% versus 79.8% +/- 4.3% (P > 0.05). 99mTc-L,L-EC has a very low plasma protein binding (31% +/- 6.8%) as compared to 99mTc-MAG3 (88% +/- 5.2%) and a larger volume of distribution. Although the exact mechanism responsible for the high plasma clearance of 99mTc-L,L-EC is not yet fully known, we conclude that this new agent merits further clinical evaluation in patients to establish its value as a renal radiopharmaceutical.

Adult↗

Technetium-99m hexamethylpropylene amine oxime labelled leucocyte scintigraphy in ulcerative colitis and Crohn's disease.

Technetium-99m hexamethylpropylene amine oxime labelled leucocyte scintigraphy (LS) was performed on 45 occasions in 30 patients with ulcerative colitis and on 53 occasions in 34 patients with Crohn's disease. Serial images were taken following re-injection of the labelled leucocytes. The segmental extent of the inflammation and the grade of the leucocyte uptake were calculated, and compared with the laboratory results and colonoscopy findings. The sensitivity and specificity of LS proved higher in ulcerative colitis (87% and 93%) than in Crohn's disease (53% and 89% in cases with large intestine involvement, and 82% and 100% in cases with small intestine involvement). The activity of the process determined by LS correlates with the alpha 2-globulin level (r = 0.47), fibrinogen level (r = 0.50), fS iron level (r = -0.57), sedimentation (r = 0.44), leucocyte count (r = 0.38), platelet count (r = 0.34) and Best index (r = 0.31) in ulcerative colitis, but not in Crohn's disease.

Adolescent↗

Evaluation of single-photon emission tomography imaging of supratentorial brain gliomas with technetium-99m sestamibi.

Single-photon emission tomography (SPET) with technetium-99m sestamibi (MIBI) was carried out in 61 adult patients with supratentorial expanding brain lesions. Thirty-one patients had pathologically proven malignant glioma. Ten patients had pathologically proven low-grade glioma, while another 12 patients had a clinical diagnosis of low-grade glioma. The other eight patients had a variety of lesions including radiation necrosis (3), abscess (2), ischaemic stroke (2) and primary brain lymphoma (1). SPET was performed 15 min after administration of 740-930 MBq MIBI and transverse, sagittal and coronal views were reconstructed. Using computed tomography or magnetic resonance imaging guidance, a MIBI uptake index was computed as the ratio of counts in the lesion to counts in the contralateral homologous region. In high-grade gliomas, the MIBI index ranged from 1.9 to 6.6 (mean 3.6 +/- 1.4) whereas it ranged from 0.8 to 1.7 (1.1 +/- 0.2) in the pathologically proven low-grade group (P < 0.01). No significant difference was found between the two low-grade groups (1.1 +/- 0.2 vs 1.1 +/- 0.2). No overlap was found between high-grade and low-grade glioma index values. Patients with suspected radiation necrosis, cerebral abscess or ischaemic stroke did not demonstrate high MIBI uptake (0.9-2.2), whereas one patient with brain lymphoma did (3.9). This study suggests that MIBI SPET imaging is of value in distinguishing low-from high-grade supratentorial gliomas in adults.

Adult↗

Optimized localization of bacterial infections with technetium-99m labelled human immunoglobulin after protein charge selection.

To improve the scintigraphic detection of bacterial infections a protein charge-purified fraction of polyclonal human immunoglobulin was applied as a radiopharmaceutical. This purification was achieved by attaching the immunoglobulin to an anion-exchanger column and by obtaining the column-bound fraction with buffer. The binding to bacteria in vitro and the target to non-target ratios of an experimental thigh infection with Staphylococcus aureus or Klebsiella pneumoniae in mice were evaluated to compare the purified and the unpurified immunoglobulin. The percentage of binding to all gram-positive and gram-negative bacteria used in this study was significantly (P < 0.03) higher for the purified than for the unpurified immunoglobulin. For the in vivo study, mice were infected in the thigh muscle with Staph. aureus or K. pneumoniae. After 18 h 0.1 mg of technetium-99m labelled polyclonal immunoglobulin or 99mTc-labelled protein charge-purified polyclonal human immunoglobulin was administered intravenously. At all time intervals the target (infected thighs) to non-target (non-infected thighs) ratios for both infections were significantly higher (P < 0.03) for protein charge-purified polyclonal immunoglobulin than for unpurified polyclonal human immunoglobulin. Already within 1 h the infected tissues could be detected by the purified immunoglobulin. It is concluded that 99mTc-labelled protein charge-purified immunoglobulin localizes both a gram-positive and a gram-negative thigh infection more intensely and faster than 99mTc-labelled unpurified immunoglobulin.

Animals↗

Diagnosis of brain death with technetium 99m hexamethylpropylene amine oxime.

We report on the utility of technetium 99m hexamethylpropylene amine oxime (99mTc-HMPAO) to diagnose brain death following cardiac surgery on a 49-year-old man with triple-vessel coronary artery disease. The imaging parameters and criteria to diagnose irreversible brain damage (brain death) with 99mTc-HMPAO are outlined. Brain imaging with this tracer seems to be more reliable than classic radionuclide angiography and has a potential value to confirm the diagnosis of brain death at an early stage. In addition, it may be used to evaluate the perfusion pattern to other vital organs with potential for transplantation.

Brain Death↗