Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SILICA”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49Linked to original sources

Kinetic modeling of adsorption of di-2-pyridylketone salicyloylhydrazone on silica gel.

The kinetics of DPKSH (di-2-pyridylketone salicyloylhydrazone) adsorption onto silica gel has been investigated at (25+/-1) degrees C and pH 1 and 4.7. The kinetics of adsorption of DPKSH is discussed using three kinetic models, the first-order Lagergren model, the pseudo-second-order model, and the intraparticle diffusion model. The adsorption of DPKSH, at pH 1 and 4.7, onto silica gel proceeds according to the pseudo-second-order model and the correlation coefficients were very close to 1. The intraparticle diffusion of DPKSH molecules within the silica gel particles was identified as the rate-limiting step. The parameters of the pseudo-second-order model are q(max,calc)=1.02 x 10(-4) and 1.5 x 10(-4) g DPKSH/g silica; k(2)=3.01 x 10(4) and 9.67 x 10(4) h(-1)g silica/g DPKSH, respectively, for pH 1 and 4.7.

Adsorption↗

Wet sol-gel derived silica for controlled release of proteins.

The potential of wet sol-gel derived silica gels as new matrices for the entrapment and sustained release of proteins was investigated. Model proteins, BSA, ribonuclease-A and avidin, with differing molecular weights and/or isoelectric points, were entrapped in two silica polymer formulations having different silica contents (4% and 12% wt/v). The conformational stability of the proteins after entrapment and their release after immersion into physiological conditions were measured. Circular dichroism analysis showed that protein conformation is maintained after entrapment and stability is enhanced. Protein-free formulations were injected intramuscularly into BALB/c mice to monitor the in vivo fate of the matrix, and the results showed that the gel is totally reabsorbed, without any apparent surrounding inflammation process. The time required for matrix bioerosion varied between one to three weeks, depending on its SiO(2) content. Erosion was also measured in vitro and the contribution of erosion and diffusion to the release of the embedded proteins was quantified. These data indicate that wet silica polymers obtained by the sol-gel route are promising matrices for the sustained release of protein drugs.

Animals↗

Retention behavior of common mono- and divalent cations on calcinated silica gel columns in ion chromatography with conductimetric detection and the use of nitric acid, containing crown ethers, as eluents.

Ion chromatographic behavior of common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) on columns packed with silica gels (Super Micro Bead Silica Gel B-5, SMBSG B-5) calcinated at 200, 400, 600, 800 and 1000 degrees C for 5 h was investigated using nitric acid containing crown ethers [18-crown-6 (1,4,7,10,13,15-hexaoxacyclooctadecane) and 15-crown-5 (1,4,7,10,13-pentaoxacyclopentadecane)] as eluent. When using 0.5 mM HNO3 as the eluent, the calcination had almost no effect on the improvement of peak resolution between these mono- and divalent cations. In contrast, when using 0.5 mM HNO3 containing crown ethers as the eluent, with increasing the calcinating temperature, the amount of crown ethers adsorbed on the corresponding calcinated SMBSG B-5 silica gels columns increased and, as a consequence, peak resolution between these mono- and divalent cations was quite improved. Excellent simultaneous separation of these mono- and divalent cations was achieved on column (150x4.6 mm I.D.) packed with the SMBSG B-5 silica gel calcinated at 1000 degrees C by elution with 0.5 mM HNO3 containing either 1.0 mM 18-crown-6 or 5.0 mM 15-crown-5.

Cations, Divalent↗

Simultaneous separation of common mono- and divalent cations on an acid-treated silica gel column by ion chromatography with indirect photometric detection and tyramine-oxalic acid, containing 18-crown-6 as eluent.

The application of unmodified silica gel (Super Micro Bead Silica Gel B-5, SMBSG B-5) as cation-exchange stationary phase in ion chromatography with indirect photometric detection for common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) was carried out using 0.75 mM tyramine [4-(2-aminoethyl)phenol]-0.25 mM oxalic acid at pH 5.0 as the eluent. Although complete group separation between these mono- and divalent cations was achieved on the SMBSG B-5 column (150x4.6 mm I.D.) in 12 min, peak shapes of NH4+ and K+ were strongly tailed. Hence, the application of SMBSG B-5 silica gel treated with conc. hydrochloric acid at reflux-temperature for 12 h for the simultaneous separation of these cations was carried out. Although the retention volumes of these cations decreased on the acid-treated SMBSG B-5 silica gel column, the peak shapes of NH4+ and K+ were quite improved. Excellent simultaneous separation and highly sensitive detection at 275 nm [detection limits (signal-to-noise ratio of 3 and injection volume of 20 microl), 0.34 microM for Li+, 0.47 microM for Na+, 0.39 microM for NH4+, 0.59 microM for K+, 0.24 microM for Mg2+ and 0.28 microM for Ca2+] were achieved in 15 min on the acid-treated SMBSG B-5 column using 0.5 mM tyramine-0.2 mM oxalic acid-10 mM 18-crown-6 (1,4,7,10,13,15-hexaoxacyclooctadecane) at pH 5.5 as the eluent.

Cations, Divalent↗

Simultaneous separation of common mono- and divalent cations on silica gel modified with aluminium by non-suppressed ion chromatography with conductimetric detection and nitric acid-15-crown-5 as eluent.

The modification of silica gel with aluminium by a coating method was very effective for the preparation of silica-based stationary phases which acted as a cation exchanger under strongly acidic conditions. However, the separation of common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) on an aluminium-adsorbing silica (Al-Silica) column was moderate by a conductimetric detection ion chromatography (IC) with strongly acidic eluents. Then, the addition of various crown ethers (12-crown-4, 15-crown-5 and 18-crown-6) in acidic eluent was carried out. As a result, it was found that 15-crown-5 was most effective for the improvement of peak resolution. Excellent separation of these cations was achieved in 20 min by elution with 2 mM nitric acid-2 mM 15-crown-5. The proposed IC was successfully applied to the determination of major cations in various natural waters.

Aluminum↗

In vitro release of dexmedetomidine from silica xerogel monoliths: effect of sol-gel synthesis parameters.

Dexmedetomidine, an alpha 2-agonist, was incorporated as a hydrochloride salt into silica xerogel in order to evaluate the effect of sol-gel synthesis parameters: pH of the sol, water/alkoxide molar ratio, drug concentration and size of the device on the drug release rate and degradation rate of the matrix. This study showed that diffusion controlled the release of dexmedetomidine from silica xerogel prepared between pH 1 and pH 5. The drug release was, however, slowest near the zero charge of silica xerogel (pH 2-3). The burst of dexmedetomidine, a lipophilic, but in the form of hydrochloride salt water-soluble drug, was increased from the matrix prepared either below or above the isoelectric point. It follows that the optimum pH for preparing a drug delivery device for dexmedetomidine, is near the zero charge of silica xerogel, where the degradation of the matrix was also slowest. In addition to processing pH, the release rate of drugs can be controlled by changing the water/alkoxide molar ratio of the sol.

Adrenergic alpha-Agonists↗

An ion-imprinted functionalized silica gel sorbent prepared by a surface imprinting technique combined with a sol-gel process for selective solid-phase extraction of cadmium(II).

A new ion-imprinted thiol-functionalized silica gel sorbent was synthesized by a surface imprinting technique in combination with a sol-gel process for selective on-line, solid-phase extraction of Cd(II). The Cd(II)-imprinted thiol-functionalized silica sorbent was characterized by FT-IR, the static adsorption-desorption experiment, and the dynamic adsorption-desorption method. The maximum static adsorption capacity of the ion-imprinted functionalized sorbent was 284 micromol g(-1). The largest selectivity coefficient for Cd(II) in the presence of Pb(II) was over 220. The static uptake capacity and selectivity coefficient of the ion-imprinted functionalized sorbent are higher than those of the nonimprinted sorbent. The breakthrough capacity and dynamic capacity of the imprinted functionalized silica gel sorbent for 4 mg L(-1) of Cd(II) at 5.2 mL min(-1) of sample flow rate were 11.7 and 64.3 micromol g(-1), respectively. No remarkable effect of sample flow rate on the dynamic capacity was observed as the sample flow rate increased from 1.7 to 6.8 mL min(-1). The imprinted functionalized silica gel sorbent offered a fast kinetics for the adsorption and desorption of Cd(II). The prepared ion-imprinted functionalized sorbent was shown to be promising for on-line, solid-phase extraction coupled with flame atomic absorption spectrometry for the determination of trace cadmium in environmental and biological samples. All competitive ions studied did not interfere with the determination of Cd(II). With a sample loading flow rate of 8.8 mL min(-1) for 45-s preconcentration, an enhancement factor of 56, and a detection limit (3sigma) of 0.07 microg L(-1) were achieved at a sampling frequency of 55 h(-1). The precision (RSD) for 11 replicate on-line sorbent extractions of 8 mug L(-1) Cd(II) was 0.9%. The sorbent also offered good linearity (r = 0.9997) for on-line, solid-phase extraction of trace Cd(II).

Adsorption↗

A method to circumvent the lot number of activated carbon affecting the performance of activated carbon silica gel columns used for cleanup of blood samples for analysis of 29 hazardous organochlorine compounds.

We have previously described the use of a tandem simplified multilayer silica gel-activated carbon dispersed silica gel (TS-ML-AC) column for the cleanup of blood samples for the analysis of 29 hazardous organochlorine compounds (OCs)--the 17 major polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/DFs) and 4 non-ortho- and 8 mono-ortho-polychlorinated biphenyls (PCBs). We noted that the performance of the activated carbon-silica gel (ACS) column (lower column) varied with the lot number of the ACS. In this study, we compared the elution profiles of OCs eluted on 5 ACS columns, each with a different ACS lot number, and found that only mono-ortho-PCBs #114 and #123 were affected by lot number. The problem was that the 50 ml of n-hexane required to elute all the OCs from the simplified multilayer silica gel (MLS) column (upper column) into the AC column (lower column) also eluted varying amounts of PCBs #114 and #123 from the ACS column by ACS lot number. Although we could prevent PCBs #114 and #123 from being eluted from the ACS column by reducing the n-hexane volume to 10 ml, this volume was not sufficient to elute all the OCs from the MLS column. We solved this by separating the two columns; the sample solution was eluted with 50 ml of n-hexane from the MLS column, this eluate was concentrated to about 0.3 ml using a rotary evaporator, and then the concentrated solution was cleaned up on the ACS column. The recovery rates of #114 and #123 from blood samples were above 70% and the relative standard deviations of their concentration were below 10%, irrespective of the lot number, compared with recovery rates of 45-79% for #114 and 59-89% for #123, and relative standard deviations of their concentration above 15% when 50 ml of n-hexane was run through the tandem column. Our modified method affords reliable and reproducible cleanup of blood samples for analysis of 29 OCs, irrespective of the ACS lot number.

Charcoal↗

Laboratory evaluation of silica gel sorbent tubes for sampling hydrogen fluoride.

The NIOSH sampling and analytical method for inorganic acids employs a silica gel sorbent tube for the collection of five common inorganic acids with simultaneous determination of these acids in a single sample by ion chromatography. When the method was extended to the determination of hydrogen fluoride (HF) the sampled HF reacted with the silica gel and glass fiber of the sampler, but the reaction products remained trapped on the sorbent. Silica gel samplers were evaluated for the collection of HF from laboratory generated atmospheres. Factors tested included capacity, storage stability, humidity, accuracy and precision. Based on comparison with impinger collection, the mean recovery of HF from silica gel tube samples was 100.7% with a precision of 0.144.

Adsorption↗

Extraction of heavy metals by 2-mercaptoethoxy groups attached to silica gel.

Silica gel is currently being used as a support for various straight chain mono- and bifunctional compounds such as amines, thiols (mercaptans), and mercaptoalochols. The current study reports the results of an investigation of a 2-mercaptoethoxy moiety covalently attached to silica gel. The condensation was effected by acid-catalyzed condensation of toluene solution of 2-mercaptoethanol and silica gel and azeotropically removing the water using a Dean-Stark tube. As a coordinating agent, this bifunctional compound was used in the removal of copper(II), cadmium(II), and lead(II) from standard aqueous solutions. Using silica gel support, the removal percentages were 91-93% for the three metals.

Cadmium↗

Dynamics of green fluorescent protein mutant2 in solution, on spin-coated glasses, and encapsulated in wet silica gels.

Single-molecule experiments are performed by investigating spectroscopic properties of molecules either diffusing in and out of the observation volume or fixed in space by different immobilization procedures. To evaluate the effect of immobilization methods on the structural and dynamic properties of proteins, a highly fluorescent mutant of the green fluorescent protein, GFPmut2, was spectroscopically characterized in bulk solutions, dispersed on etched glasses, and encapsulated in wet, nanoporous silica gels. The emission spectrum, the fluorescence lifetimes, the anisotropy, and the rotational correlation time of GFPmut2, encapsulated in silica gels, are very similar to those obtained in solution. This finding indicates that the gel matrix does not alter the protein conformation and dynamics. In contrast, the fluorescence lifetimes of GFPmut2 on glasses are two-to fourfold higher and the fluorescence anisotropy decays yield almost no phase shifts. This indicates that the interaction of the protein with the bare glass surface induces a significant structural perturbation and severely restricts the rotational motion. Single molecules of GFPmut2 on glasses or in silica gels, identified by confocal image analysis, show a significant stability to illumination with bleaching times of the order of 90 and 60 sec, respectively. Overall, these data indicate that silica gels represent an ideal matrix for following biologically relevant events at a single molecule level.

Anisotropy↗

Nanosized Ni/SiO2 catalyst prepared by homogeneous precipitation in wet silica gel.

A Ni/SiO2 catalyst was prepared by homogeneous precipitation of nickel hydroxide in a sol-gel-derived wet silica gel. The preparation process consists of two successive steps: gelation of silica in the presence of nickel nitrate and urea at 50 degrees C, followed by aging at higher temperature, typically at 80 degrees C, to decompose the urea. The decomposition of urea increases the pH of the solution in the wet gel, leading to the concurrence of structural rearrangement of silica gel and deposition of nickel species. As a result, the structure of the silica changes from a ramified polymeric network into particle aggregates that entrap the nickel cations in the particles. The resulting Ni/SiO2 contains large mesopores that have high thermal stability up to 1000 degrees C and highly dispersed Ni metal particles with typical crystallite size of 4 nm even at high Ni content at 20 wt%.

Catalysis↗

HPLC retention behaviors of poly-aromatic-hydrocarbones on Cu(II)-octabromotetrakis(4-carboxyphenyl)porphine derivatives-immobilized aminopropyl silica gels in polar and non-polar eluents.

As one of approaches of developing novel HPLC stationary phases, we prepared Cu-octabromotetrakis(4-carboxyphenyl)porphine derivative-immobilized silica gels (Cu-OBTCPP(D)), and evaluated the availability of the resultant Cu-OBTCPP(D) as a stationary phase for separation of poly-aromatic-hydrocarbons (PAHs) and their related compounds. A Cu-OBTCPP(D) column was revealed to have an ability to separate simple PAHs and be useful as a stationary phase in both polar and non-polar eluents. The retention property of the Cu-OBTCPP(D) column was evaluated in various comparative experiments using commercially available columns. In comparison with 2-(1-pyrenyl)ethyl dimetylsilyl silica gel column (PYE column) regarding the retention behavior for PAHs etc., the Cu-OBTCPP(D) column showed stronger interactions involving pi electron in non-polar eluent than PYE column. In comparison with a pentabromobenzyloxy propylsilyl silica gel column (PBB column) regarding the influence of bromination, the Cu-OBTCPP(D) column was affected differently from the PBB column. In comparison with nitrophenylethyl silica gel column (NPE column) regarding the retention behavior for compounds having a dipole in a non-polar eluent, the Cu-OBTCPP(D) column showed electrostatic interactions such as dipole-dipole interaction equivalent to or larger than the NPE column.

Chemical Phenomena↗

Preconcentration and determination of mercury(II) at a chemically modified electrode containing 3-(2-thioimidazolyl)propyl silica gel.

A mercury-sensitive chemically modified graphite paste electrode was constructed by incorporating modified silica gel into a conventional graphite paste electrode. The functional group attached to the (3-chloropropyl) silica gel surface was 2-mercaptoimidazole, giving a new product denoted by 3-(2-thioimidazolyl)propyl silica gel, which is able to complex mercury ions. Mercury was chemically adsorbed on the modified graphite paste electrode containing 3-(2-thioimidazolyl)propyl silica (TIPSG GPE) by immersion in a Hg(II) solution, and the resultant surface was characterized by cyclic and differential pulse anodic stripping voltammetry. One cathodic peak at 0.1 V and other anodic peak at 0.34 V were observed on scanning the potential from -0.1 to 0.8 V (0.01 M KNO3; v = 2.0 mV s(-1) vs. Ag/AgCl). The anodic peak at 0.34 V show an excellent sensitivity for Hg(II) ions in the presence of several foreign ions. A calibration graph covering the concentration range from 0.02 to 2 mg L(-1) was obtained. The detection limit was estimated to be 5 microg L(-1). The precision for six determinations of 0.05 and 0.26 mg L(-1) Hg(II) was 3.0 and 2.5% (relative standard deviation), respectively. The method can be used to determine the concentration of mercury(II) in natural waters contaminated by this metal.

Calibration↗

[Preparation and evaluation of 2,6-di-O-pentyl-beta-cyclodextrin bonded silica stationary phase for high performance liquid chromatography].

In order to improve the chiral separation capability of the conventional beta-cyclodextrin bonded-silica gel stationary phase, 2,6-di-O-pentyl-beta-cyclodextrin bonded stationary phase (PCDS) was prepared via a long spacer. The resulted bonded-silica stationary phase was characterized by three methods, namely Fourier transform infrared, Molisch color reaction, X-ray optical electrical energy spectrogram. The chromatographic performances of PCDS were investigated by using liquid chromatography with toluene, dimethyl phthalate, and phenanthrene as solutes, and their retention mechanism was investigated and discussed. The results show that the introduction of pentyl to beta-cyclodextrin leads to enhancement of the retention of the solutes. The chiral separation capability of the new bonded-silica stationary phase was evaluated by using liquid chromatography with some chiral drugs. Some of the enantiomers such as chlorphenamine maleate and bupropion hydrochloride were separated by heptakis (2,6-di-O-pentyl)-beta-cyclodextrin bonded silica stationary.

Chromatography, High Pressure Liquid↗

Problems connected with HPLC separation of pilocarpine from its degradation products by means of silica gel and water-based mobile phase.

HPLC separation of pilocarpine from its degradation products (isopilocarpine, pilocarpic acid and isopilocarpic acid) was studied on unmodified silica gel stationary phase. An acidified aqueous solution of inorganic salts with addition of methanol served as the mobile phase. The influence of silica gel used, methanol content, mobile phase pH, anion of acids and/or inorganic salts and column temperature on solute retention, separation selectivity as well as peak shape was studied and partly explained. A significant dependence of the properties of the resulting separation system on the silica gel used was found. A test was proposed for evaluation of silica gel suitability.

Chromatography, High Pressure Liquid↗

Was there sufficient justification for the 10-fold increase in the TLV for silica fume? A critical review.

In 1992, the Threshold Limit Value (TLV) for amorphous silica fume produced as a by-product of metallurgical processes was revised upwards from 0.2 mg/m3 (respirable dust) to 2.0 mg/m3. Comparison of the documentation justifying the lower TLV published by the ACGIH in 1989, with the subsequent documentation justifying the higher value published in 1992, does not support this increase. Following an outline of the problem areas existing in interpretational difficulties of experimental and review material in the silica fume bibliography, this paper provides a detailed examination of the six additional references cited in the 1992 documentation. All additional material suggests a need for extra caution, particularly with respect to recent experimental work in Australia on the sizing of silica fume. This paper concludes that the health evidence supports a TLV for silica fume closer to 0.3 mg/m3 rather than the current 2.0 mg/m3 now adopted in the U.S. and Australia.

Air Pollutants, Occupational↗

Nested case-control study of esophageal cancer in relation to occupational exposure to silica and other dusts.

BACKGROUND: Standardized proportionate mortality ratio (SPMR) was found to be 2.2 (95% CI = 1.3-3.5) for esophageal cancer (EC) among workers exposed to refractory brick dust in a large iron-steel complex in China. METHODS: A nested case-control design within a cohort of industrial workers. One hundred and twenty-five EC cases and 250 controls were identified from the death registry file. Interviews were conducted of the next of kin for past exposure information on job, domestic, and lifestyle factors. History of occupational exposure to various dusts was reconstructed from personnel files and by interviewing colleagues utilizing a job-exposure matrix. RESULTS: After adjusting for confounders, occupational exposure to silica dust was the most important risk factor among all variables investigated, with a 2.8-fold risk and a clear dose-response by length of exposure. Alcohol drinking (OR = 1.8) and coal cooking (OR = 2.0) were risk factors and high consumption of fruit diet (OR = 0.5) and meat diet (OR = 0.6) were protective factors. CONCLUSIONS: The relationship between occupational exposure to silica dust and the risk of EC found in an earlier SPMR study was confirmed. Ingestion of silica particles after lung clearance may increase the risk of EC among workers exposed to silica.

Aged↗