Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Knee Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49Linked to original sources

Blood transfusions and postoperative infections in patients undergoing elective surgery.

BACKGROUND: Postoperative infections result from the interactions of bacteria, the surgical technique, and host defense mechanisms. Thus, identifying single determinant factors has proved difficult. MAGNITUDE OF THE RISK: In a recent survey of 2,809 colorectal resections, transfusion was the single most powerful risk factor for postoperative infection. In patients undergoing primary hip or knee prosthesis insertion, the transfusion of allogeneic blood increased the risk of a deep-seated infection by a factor of 12. MECHANISMS: Several host defense mechanisms are impaired by blood products. The initial hypothesis incriminated the transfused white blood cells, but this paradigm has since been challenged. The effects of free serum iron, the blood storage time, and the presence in stored blood of bioactive substances such as inhibitors of metalloproteinase-1 may also be important. CONCLUSION: It is worth pursuing efforts to emphasize autologous blood transfusion and the reinfusion of shed blood as blood conservation strategies, as these practices reduce the risk of infectious complications.

Arthroplasty, Replacement, Hip↗

[Comparison of roentgenological, macroscopic and histological degree of degeneration in varus gonarthrosis].

In 20 cases of varus gonarthrosis the degree of severity of osteoarthrosis was assessed preoperatively, intraoperatively and postoperatively for the medial and lateral compartments, respectively. The preoperative assessment was carried out on the basis of x-ray taken in an anterior-posterior and lateral view, whereas the intraoperative assessment was based on the recognizable macroscopic alteration of the femur and tibia. Following implantation of a total knee prosthesis, the resected osteocartilogical samples were assessed from a histological point of view. In the case of varus gonarthrosis there is a distinct difference in the degree of degeneration in the medial and lateral compartments. This difference becomes less noticeable if the assessment is carried out intraoperatively. The histological analysis shows that there are certainly differences between the compartments from a quantitative point of view but a late stage of osteoarthrosis was discernible both medially and laterally. From a histological point of view the radiological concept of the so-called "unicompartmental varus gonarthrosis" cannot be supported. In both compartments the osteoarthrotic process is more uniform than is to be expected.

Aged↗

[Pigmented villonodular synovitis of the knee. Treatment results in 22 cases].

PURPOSE OF THE STUDY: The authors report their experience about 22 cases of pigmented villonodular synovitis of the knee observed between 1970 and 1997. The authors studied the results of treatments according to localization, evolutionary stage and condition of an early diagnosis. MATERIAL AND METHODS: Among thirty three cases of pigmented villonodular synovitis treated during the same period the knee was involved in twenty two cases. Diagnosis was done or highly suspected in 13 cases because of significant symptoms (iterative hemarthrosis, bony gap in both articular components of the joint) or by MRI. The biopsy performed in each case allowed histological assessment in 22 patients. Surgical treatment was achieved in 19 patients. Three knees were not operated (two patients refused; one had a synoviorthesis) the treatment was a synovectomy alone for fifteen patients; four patients, needed a knee prosthesis, because of important degenerative joint disease. RESULTS: Fourteen patients, with a mean follow-up of five years were reviewed. Four had a recurrence which appeared between three and eight years after subtotal synovectomy for diffuse synovitis. There were no recurrence after arthroplastic treatment and in localized lesions. DISCUSSION: Pigmented villonodular synovitis should be treated as soon as possible but its different clinical features make diagnosis sometimes difficult. Because of an aggressive tendency of the disease which finds expression in extensive lesions in joint and bone, and early diagnosis allowed by MRI could make the prognosis more favourable. CONCLUSION: Surgical synovectomy is the usual treatment. In evolved stages arthroplasties are performed. Localized lesions and recurrences should need arthroscopic treatment.

Adolescent↗

Filterability of autotransfusion blood cells and plasma after total knee arthroplasty.

Postoperatively filtered drain blood can be used for autotransfusion, but quality has been questioned. The blood contains activated or destroyed blood cells, debris, and chemicals from the wound. The ConstaVac autotransfusion system was used in 18 patients operated with a total knee prosthesis. Samples were taken from drain blood and compared with venous blood at different sampling times (to 24 h) and different incubation conditions. Micro-rheology was measured as pore filterability (5 microm) in whole blood, erythrocyte resuspension, and plasma. The filtration flow resistance was significantly lower in drain whole blood, but was unchanged in erythrocyte resuspension compared to venous blood. However, the rate of filter clogging was unchanged in drain whole blood, but was increased in the erythrocyte resuspension at 2 h. Drain plasma filterability indicated particle contamination. In total, the filterability of resuspended drain erythrocytes and cell-free plasma is affected, but this is not significant enough to have effects on drain whole blood filterability which is increased, possibly due to the leukocyte reduction. From these perspectives, we consider drain blood acceptable for autotransfusion.

Aged↗

[Factors associated with blood transfusion during anesthesia for scheduled hip or knee arthroplasty in France].

GOAL OF THE STUDY: To determine over a whole country what are the factors associated with an intraoperative homologous blood transfusion and with the use of autologous techniques (preoperative autologous blood donation: PABD; acute normovolemic hemodilution: ANVH; intraoperative red cell salvage: IRCS). STUDY DESIGN: National enquiry using a large representative sample (3 days of anaesthesia in France). METHODS: Univariate followed by multivariate analyses of data gathered in 1996 during the survey leaded by the French society of anaesthesia and intensive care (Sfar) and corresponding to 884 scheduled hip and knee prosthesis surgical procedures. RESULTS: Factors associated with a decreased use of PABD programme were: 1--old age and high ASA physical status; 2--procedures of short duration. By contrast, an increased use of PABD was associated with anaesthetics in which a closed circuit had been used. Except for a significant association with increasing age and with absence of PABD used, no additional factor was found to be linked with ANVH. No factor among those studied was found related to the use of IRCS. Homologous blood transfusion was more frequently used in ASA > or = 3 patients, in long duration surgeries while its use was decreased in patients with PABD (odds ratio--for reduction by PABD: 4.4 [95% confidence interval: 2.2-8.8]). Homologous blood transfusion was not related to the use of ANVH or IRCS. CONCLUSION: These data obtained from a large national survey confirm previously published studies and meta-analyses and are in agreement with current recommendations. An unexpected relation between PABD and closed circuit anaesthesia has been found.

Aged↗

The Total Condylar III prosthesis in complex knee reconstruction.

Sixty-one Total Condylar III (TC III) prostheses were implanted in 59 patients at the authors' institution between March 1977 and December 1987. Among the knees with adequate clinical and roentgenographic data, the average follow-up period was 6.1 years. There were six primary arthroplasties and 29 revisions in this group. The primary diagnosis was osteoarthrosis in 17 patients, rheumatoid arthritis in 16 patients, and juvenile rheumatoid arthritis in two patients. The knee score improved from 21.9 preoperatively to 73.7 at last follow-up evaluation. Based on the knee score, there were 71% good or excellent results. There were three failures (8.6%). Radiolucent lines were present in at least one component in 71% of patients, but few of these were considered significant. Although rarely needed, the TC III prosthesis has been shown to be a satisfactory and durable solution to complex knee reconstructive problems including severe deformity, ligamentous instability, and bone loss.

Adult↗

The morselized and impacted bone graft. Animal experiments on proteins, impaction and load.

The results of primary hip replacements are good. However, dealing with a loose prosthesis has been problematic, especially when major bone deficiencies are encountered. These problems appear to have been solved by the introduction of the Slooff-Ling method of using morselized and impacted allograft chips. The clinical results are excellent in the hands of the innovators. However, it remains confusing that a thick layer of dead, broken, immunogenic tissue taken from another individual does not resorb and collapse during remodeling. Still harder to understand is the impression, as judged by radiography, that this thick layer seems to incorporate and remodel up to a distance of perhaps 10 mm or more from the host bone, whereas the ingrowth distance into a non-morselized graft is limited to a few mms. To clarify the biological basis of the morselized and impacted grafts better, the present study was stated. Three hypotheses were initially proposed to explain the good clinical results: 1. Morselization releases growth factors present in the graft (osteoinduction). 2. Impaction makes it easier for the ingrowing bone to climb up into the graft (osteoconduction). 3. The compliance or elasticity of the graft allows the load to produce deformations that stimulate bone formation (mechanical load). In the first studies, bone chambers were implanted in rats and the distance of new bone ingrowth into a graft in the chamber was measured. In Paper I, a morselized graft was deproteinized by slow heating under high pressure. Ingrowing bone did not reach so far into the deproteinized graft as into a non-treated one. We concluded that the proteins present in the graft partly determine how far ingrowing new bone will extend into a graft. In Paper II, a cancellous graft was impacted so that the bone volume fraction of the graft rose from 35% in the unimpacted to 65%. The impacted grafts were compared to unimpacted ones and it was shown that impaction reduced the ingrowth of new bone into a graft in the chamber at six weeks. In Paper III, this somewhat unexpected finding was further studied. Syngeneic and allogeneic grafts showed a reduced ingrowth distance at six weeks when impacted, compared to unipacted controls. However, the reduction was not found when the time for ingrowth was extended to 12 weeks, indicating a possible catch-up phenomenon. Moreover, an exogenously applied growth factor, osteogenic protein-1, was found to have increased the ingrowth distance of new bone into impacted grafts at six weeks. In Paper IV, a rabbit knee prosthesis was developed to study the effect of a mechanical load on the remodeling of a morselized and impacted graft. All rabbits had their tibial marrow cavity cleansed of cancellous bone, which was replaced by a morselized and impacted bone graft. Six rabbits received a complete tibial prosthesis with a tibial load-bearing tray and a stem transferring the load to the impacted graft with each step made by the rabbit. Another six rabbits had only the stem, without the tibial tray, inserted into the impacted graft. With this design, the load from walking was not transferred to the graft, since there was no joint surface replacement to transfer the load to the stem and the graft. Thus, the graft was loaded in rabbits receiving a full prosthesis, whereas it was unloaded in the animals receiving only the stem. New bone formation and resorption of the graft were increased in the loaded grafts, and we concluded that a load increases the rate or speed of remodeling. In Paper V, four patients were operated on for vertebral fractures. The fractures were stabilized by plates and the vertebral bodies packed with autogenous morselized graft. After 1.5 years, when the fractures were clinically and radiographically healed, a biopsy was taken. It was found, that even after such a long time, large areas remained unremodeled and sometimes even unrevascularized. In some parts, necrotic graft trabeculae were embedded in fibrous vasc

Animals↗

A multidirectional motion pin-on-disk wear test method for prosthetic joint materials.

A realistic pin-on-disk wear test method for prosthetic joint materials has been developed. The new method, called circularly translating pin-on-disk (CTPOD), yields wear rates and wear mechanisms similar to those observed in retrieved polyethylene acetabular cups. In the established methods, where a polyethylene specimen slides against a unidirectionally rotating, or reciprocating, metallic or ceramic counterface, the wear rate typically is two orders of magnitude too low. In the present study, also, the reciprocator gave negligible wear. In the CTPOD method, considerable wear occurs because the direction of sliding rotates relative to the polyethylene pin, hence, the molecular orientation effect of polyethylene is avoided.

Biocompatible Materials↗

Side-effects of prosthetic materials on the human body.

The authors report 6 patients (7 joints) in whom inflammation, dermal necrosis, dermatitis or fistula formation was attributed to the materials commonly used for joint endoprostheses. Histological appearances and chemical analyses of the involved tissues are presented, together with a discussion of the possible mechanism and methods of diagnosis and treatment.

Adult↗

Complications with antibiotics used prophylactically in joint replacement surgery: a case report of cephradine-induced pseudomembranous colitis.

A woman underwent joint replacement surgery with prophylactic antibiotic cover, and subsequently died as a result of pseudomembranous colitis. We have noted a high incidence of antibiotic diarrhoea with cephradine, and suggest that if administration of prophylactic antibiotics is restricted to 3 days or less, the incidence of diarrhoea would diminish, and the therapeutic value of the antibiotics would be maintained.

Aged↗

Computer-aided manufacture of individual endoprostheses. Preliminary communication.

Long-term anchorage of foreign material in vital bone has proven to be the main problem in endoprosthetics. In the authors' opinion, modelling an endoprosthetic anchorage component to the individual anatomic needs is, at present, the best way to transmit stresses harmoniously from the prosthesis to the sensitive bone, in order to utilize functional adaptation, and to guarantee long-term function. The production of a true-to-scale joint model is possible with computer-assisted tomography. This model of the joint or bone canal can be used to construct an individual endoprosthesis prior to surgery. A procedure described.

Biomechanical Phenomena↗

Determination of metallic ion transfer from an implanted prosthesis by the PIXE method.

Prostheses can release some metallic elements to the surrounding tissues, particularly when they are not covered with a biomaterial layer and when an unsealing process happens. We try to measure major and trace elements in these tissues with an experimentally sensitive method. Proton-induced X-ray emission is used to detect about 10 elements in tissue. Tissues are calcinated and deposited in a thin layer before irradiation. Results are obtained in a standard and samples from three patients. We observe contamination by Ti, Cr, Ni, and Zn in the tissues. Correlations are to be studied between these atomic transfers and prosthesis in the patient.

Hip Prosthesis↗

[The value of leukocyte scintigraphy in suspected implant infection in patients with chronic polyarthritis].

When infection of implants is suspected, optimal management requires accurate confirmation or exclusion of infection. However, in spite of demonstrative clinical signs cultures of smears or chemical parameters of inflammation frequently are ambiguous. Scintigraphy with indium-labeled white blood cells (WBC) has been reported to be sensitive and specific in the diagnosis of low-grade sepsis of the musculoskeletal system. Twenty-eight patients with possible infection were prospectively studied. Infection was suspected in 19 cases with total hip joint prosthesis, 14 cases with knee joint prosthesis and 1 case with shoulder joint prosthesis. All of them underwent scanning with indium-111-labeled WBC and subsequently underwent surgery. At surgery infections were determined by means of culture or histologic results. When correlated with culture and histologic results sensitivity of 111-indium-WBC imaging was 89% with a specificity of 67% and a predictive accuracy of 77%. In patients with rheumatoid arthritis, however, predictive accuracy of 111-indium-labeled WBC imaging was higher than with standard diagnostic methods. The difference was statistically significant (P < 0.05, chi(2)-test). In the patients examined as a whole, predictive accuracy of 111-indium-labeled WBC imaging does not differ from that of standard diagnostic methods. That is why expensive and time-consuming 111-indium-WBC imaging is not justified generally in diagnosis of infection of implants. 111-Indium-WBC imaging is well suited to supplement standard diagnostic methods in patients with rheumatoid arthritis.

Adult↗

MRSA-infected external iliac artery pseudoaneurysm treated with endovascular stenting.

A 48-year-old woman with severe juvenile-onset rheumatoid arthritis presented with a bleeding cutaneous sinus distal to her right total hip replacement scar. Methicillin resistant Staphylococcus aureus (MRSA) was isolated on culture. She had previously undergone bilateral total hip and knee replacements at aged 23 and six years later had the right knee prosthesis removed for infection, with subsequent osteomyelitis of the femoral shaft and right total hip prosthesis disruption. Peripheral arteriography was performed in view of persistent bleeding from the sinus, which revealed a 6 cm false aneurysm filling from and compressing the right external iliac artery (EIA). A PTFE-covered, balloon expandable JOSTENT was deployed in the right EIA, successfully excluding the false aneurysm and preventing further bleeding from the sinus. No graft infection was reported at 12 months. This case illustrates the potential use of endovascular stent-grafting in the treatment of an infected pseudoaneurysm.

Aneurysm, False↗

The multicentric epitheloid hemangioendothelioma of bone: a case example and review of the literature.

Epitheloid hemangioendothelioma of bone is a rare primary bone malignancy. Diagnosis can be difficult for physicians who are not experienced with bone neoplasms. We also had difficulties in diagnosis and treatment in one of our patients with a multicentric epitheloid hemangioendothelioma involving the pelvis, left femur, and left tibia. We recommend a complete skeletal survey with magnetic resonance imaging because it can reveal previously undetected lesions on conventional radiographs. We performed an extraarticular resection of the hip joint including the spina iliaca anterior inferior, resection of the femur, and amputation of the lower leg. The femur was replaced by a modular endoprosthesis. The patient is provided with an above-knee prosthesis and is able to walk even longer distances with a cane 2 years after surgery. In our opinion it is necessary to perform a wide resection of this tumour in order to treat a patient with curative intention. Palliative radiotherapy should only be used for a non-resectable tumour or in metastatic disease. Chemotherapy is not a treatment option.

Adult↗

Accelerated ageing experiments with crosslinked and conventional ultra-high molecular weight polyethylene (UHMW-PE) stabilised with alpha-tocopherol for total joint arthroplasty.

Samples of untreated ultra-high molecular weight polyethylene (UHMW-PE), UHMW-PE sterilized with gamma-rays in nitrogen atmosphere (conventional UHMW-PE, widely used for articulating surfaces in endoprostheses) and UHMW-PE, which has been crosslinked by electron beam irradiation and annealed subsequently, were stabilized with alpha-tocopherol and aged in air at 120 degrees C as well as in 10% aqueous hydrogenperoxide with 0.04 mg/ml FeCl3 as catalyst at 50 degrees C. The oxidative degradation was monitored with the help of infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), solubility measurements and size exclusion chromatography (SEC) and were compared to unstabilized samples. When aged in air at 120 degrees C, the crosslinked UHMW-PE showed a slightly slower increase of the carbonyl (CO)-number (according to DIN 53383) in FTIR than conventional UHMW-PE. A stabilisation with 0.4% w/w alpha-tocopherol resulted in an increase of lifetime by a factor of approx. 40 for all samples. Ageing in 10% aqueous H2O2 at 50 degrees C yielded similar results for all three unstabilised samples. The addition of the natural antioxidant alpha-tocopherol led to a prolongation of lifetime by a factor of approx. 2.5. A linear loss of alpha-tocopherol was detected during ageing. An increase of crystallinity as well as lamella thickness during ageing was observed with the help of DSC. The two-phase structure of crosslinked UHMW-PE with two melting endotherms at 114 degrees C and 137 degrees C was replaced very quickly by a single melting point at 130 degrees C. This effect was delayed with the stabilized samples. In the solubility and SEC measurements, a severe molecular degradation and drop of molar mass of all materials could be observed after ageing in H2O2, leading to a complete destruction and, in case of crosslinked UHMW-PE, to a serious damage of the molecular network, respectively.

Biocompatible Materials↗