Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “HEMAGGLUTINATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49Linked to original sources

Method for extracting viral hemagglutination-inhibiting antibodies from the nonspecific inhibitors of serum.

Various methods are used to remove nonspecific inhibitors from sera before titering viral hemagglutination-inhibiting antibodies. These methods have several undesirable features; some are tedious and time-consuming, some remove antibody along with nonspecific inhibitors, and different techniques are usually required to remove the nonspecific inhibitors for different viruses. This communication describes a single method that uses diethylaminoethyl-Sephadex to extract the immunoglobulin G antibodies for several viruses from nonspecific inhibitors. The procedure is fast, simple to perform, and removed the nonspecific inhibitors for influenza, Western equine encephalitis, dengue-2, and rubella viruses.

Acetone↗

Serological diagnosis of human melioidosis with indirect hemagglutination and complement fixation tests.

An indirect hemagglutination (IHA) test and a complement fixation (CF) test were evaluated from test results on sera from 212 human melioidosis patients of which 119 were culturally proved cases. Significant antibody titers (IHA titers of 1:40 or greater and CF titers of 1:4 or greater) were demonstrated with either test in all except five patients. IHA and CF titers ranged as high as 1:20,480 and 1:1,024, respectively. Antibodies were usually demonstrated by both tests 1 week after onset of disease. Transient seronegative reactions during the course of disease were seen in sera of approximately 19% of the patients with either IHA and CF but rarely with both tests. High titers in either test were obtained by the third week of disease and reached maximum levels in 4 to 5 months. Titers usually were detectable for 9 or more months. Antibodies were detected by IHA and CF tests in 80 to 100% of the sera obtained at various time intervals from 9 months to 2 or more years after disease onset. Antibody persistence occurred in patients who had a short disease course, as well as in patients with prolonged, complicated infections. The IHA test had excellent specificity when evaluated with normal human sera and diverse antimicrobial sera from hyperimmunized rabbits and human patients. The CF antigen appeared to contain common antigens with some but not all types of Pseudomonas aeruginosa. The specificity of the CF antigen could be enhanced without appreciable effect on its sensitivity by use of a titer of 1:8 in lieu of 1:4 as a criterion for a significant reaction. Either test could be used advantageously for the laboratory diagnosis of melioidosis.

Animals↗

Micro indirect hemagglutination test for Cytomegalovirus.

In an effort to obtain the flexibility and ease of performance of a rapid, serological test for detection of cytomegalovirus antibody, the indirect hemagglutination (IHA) technique was investigated by using a microserological system. Antigens were prepared from tissue cultures of infected human fibroblasts. The specificity of the cytomegalovirus antibody response detected by the IHA test correlated well with the standard neutralization test. The IHA method was more sensitive than the complement fixation test in detecting antibody in congenitally infected newborns. There appeared to be some heterologous antibody response with Herpesvirus hominis or varicella virus infections. The IHA test pattern was found to be very stable with excellent persistence of agglutination.

Antigen-Antibody Reactions↗

Detection of foot-and-mouth disease virus antibodies. II. Use of fractionated bovine antisera for improving the specificity of a "passive" hemagglutination test.

Because 7S immunoglobulin (Ig) G antibodies of low type specificity were present in mixtures with highly specific 19S IgM antibodies, many bovine antisera to foot-and-mouth disease virus (FMDV) type A(12), strain 119 cross-reacted with type O of FMDV and to some degree with type C in the passive hemagglutination (HA) test. After 19S IgM antibodies were separated by density gradient centrifugation or precipitated with 4% (w/v) polyethylene glycol, the antigen could be determined with "block" HA tests. Such tests used several antigen concentrations in the titration of each antiserum. Adding 4% (w/v) polyethylene glycol to the serum was especially convenient for rapid precipitation of 19S IgM antibodies for the test. Similar results were obtained with bovine 19S IgM antibodies to FMDV type O, subtype 1, strain Caseros and type C strain Rezende.

Aldehydes↗

Automation of a hemagglutination-inhibition test for parainfluenza 3 antibodies in bovine sera.

An automated hemagglutination-inhibition (HI) test for the "shipping fever" strain (SF-4) of parainfluenza 3 antibody in bovine sera was developed and compared to manual tube and microtiter test procedures. The automated system operating at 60 samples per hr provided the most test results per specified time period, and the manual tube test provided the least. The manual microtiter test and the automated system at 40 samples per hr, falling between the two above procedures, were comparable in the number of sera that could be titrated in 1 day by one technician. There was little difference between automated and manual test reproducibility when measured at the twofold titer one-dilution difference level. However, the automated system titrated a higher number of sera at the same titer on repeat runs than either of the manual test procedures. The automated one-quartile difference reproducibility (each twofold dilution subdivided into 4 units-"quartiles") was equal to the manual test one-dilution difference reproducibility. The standard deviation of the per cent variation from the mean of paired serum titers for 40-sample-per-hr runs ranged from +/-3.49 to +/-5.36%. The manual and automated systems were of comparable sensitivity in their detection of negative sera.

Animals↗

Passive hemagglutination-inhibition test for typing foot-and-mouth disease virus.

In addition to currently used serological tests for the occurrence of foot-and-mouth disease virus (FMDV), a specific "passive" hemagglutination-inhibition (HAI) test has been developed as a supplement. Serial twofold dilutions of antiserum (0.05 ml) were mixed with 0.05 ml of a constant concentration of FMDV. After incubating for 30 min at 37 C, agglutinating antibodies were determined by adding 0.1 ml of 2.5% virus-sensitized erythrocytes. The minimum concentration of antiserum required to agglutinate the erythrocytes defined the inhibition in the HAI test. Similar tests using different concentrations of virus to inhibit antibodies were carried out in parallel fashion. The relationship between the logarithm of the HAI titer and the concentration of inhibiting virus was nearly first order (P > 0.25). The slope was used as a measure of the relative specificities of the antigen-antibody interaction and was independent of concentration. The HAI test was type-, subtype-, strain-, and variant-specific with the viral antigens used. In particular, typing was performed directly on bovine antisera.

Animals↗

Hemagglutination inhibition for serogrouping of Neisseria meningitidis.

A hemagglutination inhibition (HI) test has been studied as an alternative to bacterial agglutination (BA) for serogrouping strains of Neisseria meningitidis isolated from clinical specimens. The HI test consists of polysaccharide antigens adsorbed to sheep red blood cells which were then agglutinated by group-specific antisera. Supernatant fluids from suspensions of meningococci were used to inhibit the agglutination. Results of the two tests agreed for 381 (80%) carrier strains. Of the remaining 95 strains, 82 (86%) were identified by HI although they were nongroupable by BA. Thus, the HI test has been shown to be more highly specific and sensitive and to be more economical of reagents and time than the BA test.

Adsorption↗

Modified hemagglutination-inhibition test for rubella employing human group O erythrocytes.

A hemagglutination-inhibition (HI) test for rubella is described which utilizes human group O, rather than 1-day-old chick, erythrocytes. The test was found to be as sensitive and reproducible for detection of rubella antibody as HI tests employing chick erythrocytes. Advantages to the use of human erythrocytes are (i) they are more available, (ii) it is unnecessary to absorb natural agglutinins from human test sera, and (iii) heparin-MnCl(2)-treated sera do not agglutinate human erythrocytes, as is sometimes the case with chick erythrocytes. Factors influencing the reliability of the test are discussed.

Agglutination Tests↗

Further studies on the anti-immunoglobulin G hemagglutination-inhibition test for influenza.

Incorporating species-specific anti-immunoglobulin G (IgG) serum into the hemagglutination-inhibition (HI) test for influenza markedly increased sensitivity without loss of specificity. The effectiveness of anti-IgG serum for augmenting antibody titers may be influenced by the variable potency of commercial anti-IgG preparations. Maximal enhancement of HI titers was achieved when anti-IgG serum and virus-antiserum mixtures were incubated at 23 C for 10 min. Precision and reproducibility of the test were within acceptable limits. Other conditions likely to affect the test were investigated.

Animals↗

Indirect hemagglutination test for chlamydial antibodies.

An indirect hemagglutination (IHA) test is described for chlamydial antibodies in psittacosis diagnostic sera; for this test tanned sheep erythrocytes sensitized with a deoxycholate extract of Chlamydia psittaci grown in Vero cell monolayers were used. Adaptation of the IHA test to the Microtiter system decreased sensitivity; nevertheless, the Microtiter-IHA test was more sensitive than the complement fixation test. Lymphogranuloma venereum antibodies also were detected by using antigen extracted from C. psittaci.

Animals↗

Improved dextran sulfate-calcium chloride method for the removal of nonspecific inhibitors with modifications for nonspecific agglutinin removal in the rubella hemagglutination inhibition test.

The dextran sulfate precipitation method for removal of nonspecific inhibitors from sera to be tested in the rubella hemagglutination-inhibition test was modified by shortening the dextran sulfate-serum mixture incubation period from 2 hr to 30 min. A comparative study using both treatment times showed no significant difference in rubella antibody titers. Reducing the treatment time even further also gave comparable results, indicating the select 30-min incubation period is not marginal for undertreatment. It was shown that 41.5% of the 159 serums tested had nonspecific agglutinins at levels from 1:8 to as high as 1:64. In each specimen, all demonstrable nonspecific agglutinin was removed by adsorption with 10%, 0- to 2-day-old chick red blood cells rather than the usually recommended 50% adult chicken erythrocytes.

Agglutinins↗

Use of trypsin-modified human erythrocytes in rubella hemagglutination-inhibition testing.

A method of treating human erythrocytes with trypsin has been modified and found to be an efficient and practical indicator system for the rubella hemagglutination-inhibition test. Both the trypsin-treated human cells and the widely used, newborn chicken erythrocytes were used in comparative testing of 464 selected diagnostic rubella serums. Results with each cell system were essentially the same. The trypsin treatment procedure has been found to be relatively simple, and with our limited testing has not presented any problems with reproducibility. Other advantages include the ready availability of human cells, greater intralaboratory standardization of the test by using the same donors over a long period of time, and elimination of adsorption of test sera with red blood cells.

ABO Blood-Group System↗

Hemagglutination inhibition of passively sensitized red blood cells.

It has been shown that sheep red blood cells sensitized with the polysaccharides of Haemophilus influenzae type B and pneumococcal types I, III, IV, VII, VIII, XII, and XIV respond readily in hemagglutination-inhibition testing and exhibit antigen inhibition at levels of 0.09 to 4.0 ng.

Animals↗