Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Exhalation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49Linked to original sources

Exhaled nitric oxide and exercise-induced bronchoconstriction in young male conscripts: association only in atopics.

This study was conducted to evaluate how bronchial responsiveness to direct and indirect stimuli relate to nitric oxide producing airway inflammation, and whether the relationship differs between atopic and nonatopic patients with various degrees of bronchial hyperresponsiveness and airway inflammation in a group of otherwise homogenous young men. We studied 181 consecutive non-smoking steroid-naive young male conscripts referred to military hospital because of respiratory symptoms suggesting asthma. Skin prick tests, spirometry, measurement of exhaled nitric oxide (FENO), and standardized airway challenges with histamine and exercise were performed. 128 patients were atopic. FENO was significantly higher in the atopic group, median 21.2 ppb, compared to 10.2 ppb in the nonatopic group. Still, 36% of all nonatopic patients had elevated FENO. Bronchial responsiveness to histamine (HIB) was similar in the two groups, but exercise-induced bronchoconstriction (EIB) was stronger in atopics (P < 0.01). FENO associated significantly with atopy (P < 0.001), severity of EIB (P < 0.001) and HIB (P = 0.006) in multiple linear regression model. In separate regression models for atopic and nonatopic patients FENO associated with severity of EIB and HIB in atopic patients only. The results were similar when patients with confirmed diagnosis of asthma were analyzed separately. Our results indicate that FENO significantly associates with EIB and HIB in atopic, but not in nonatopic steroid-naïve patients with asthmatic symptoms. The finding suggests that in such atopic patients degree of airway hyperresponsiveness may reflect severity of airway inflammation. However, in nonatopic patients with similar symptoms other mechanisms of airway hyperresponsiveness may be more important.

Adolescent↗

Exhaled nitric oxide in asthmatic children and adolescents after nasal allergen challenge.

Epidemiological data suggest a comorbidity link between nasal and bronchial allergic disease. Exhaled nitric oxide (FENO) is a sensitive marker of bronchial inflammation and increases after bronchial allergen provocation. We studied FENO in 19 children and adolescents with allergic asthma and 10 controls before and 2, 6 and 24 h after a single nasal allergen challenge. The correlation between FENO and other markers of allergic inflammation, such as eosinophils in blood and eosinophil cationic protein (ECP) in serum and nasal lavage was also assessed. FENO remained unchanged 24 h post-challenge in both steroid and steroid-naive patients. At 6 h post-challenge, FENO decreased in both asthmatics and controls. The asthmatic subjects showed a positive correlation between FENO and blood eosinophils before (r=0.71, p=0.001) and after the challenge, and between FENO and ECP in nasal lavage (r=0.62, p=0.02) 2 h after the challenge. Mean ECP in nasal lavage increased post-challenge but not significantly. We conclude that a single nasal allergen challenge does not augment bronchial inflammation although FENO, is related to blood eosinophil count and to the nasal inflammatory response. Our data do not support the theory of a direct transmission of the nasal inflammation to the lower airways.

Adolescent↗

Additive effect of eosinophilia and atopy on exhaled nitric oxide levels in children with or without a history of respiratory symptoms.

Although atopy and blood eosinophilia both influence exhaled nitric oxide (eNO) measurements, no study has quantified their single or combined effect. We assessed the combined effect of atopy and blood eosinophilia on eNO in unselected schoolchildren. In 356 schoolchildren (boys/girls: 168/188) aged 9.0-11.5 yr, we determined eNO, total serum IgE, blood eosinophil counts and did skin prick tests (SPT) and spirometry. Parents completed a questionnaire on their children's current or past respiratory symptoms. Atopy was defined by a SPT >3 mm and eosinophilia by a blood cell count above the 80th percentile (>310 cells/ml). eNO levels were about twofold higher in atopic-eosinophilic subjects than in atopic subjects with low blood eosinophils [24.3 p.p.b. (parts per billion) vs. 14.1 p.p.b.] and than non-atopic subjects with high or low blood eosinophils (24.3 p.p.b. vs. 12.2 p.p.b. and 10.9 p.p.b.) (p <0.001 for both comparisons). The additive effect of atopy and high eosinophil count on eNO levels remained unchanged when subjects were analyzed separately by sex or by a positive history of wheeze (n=60), respiratory symptoms other than wheeze (n=107) or without respiratory symptoms (n=189). The frequency of sensitization to Dermatophagoides (Dpt or Dpf) was similar in atopic children with and without eosinophilia (66.2% and 67.4%, respectively); eosinophilia significantly increased eNO levels in Dp-sensitized children as well in children sensitized to other allergens. In a multiple linear regression analysis, eNO levels were mainly explained by the sum of positive SPT wheals and a high blood eosinophil count (t=4.8 and 4.3, p=0.000), but also by the presence of respiratory symptoms (especially wheeze) and male sex (t=2.6 and 2.0, p=0.009 and 0.045, respectively). Measuring eNO could be a simple, non-invasive method for identifying subjects at risk of asthma in unselected school populations.

Analysis of Variance↗

The effect of spirometry and exercise on exhaled nitric oxide in asthmatic children.

American Thoracic Society (ATS) guidelines recommend to refrain from spirometry or exercise before measuring fractional exhaled nitric oxide (FENO) because forced breathing maneuvers might influence FENO values. However the few studies already reported in children have given conflicting results. The aim of the study was to observe to what extent spirometry or exercise could affect FENO in asthmatic children. Twenty-four asthmatic children (mean age 12.8 yr) were enrolled. Measurements of FENO were performed before and 5, 15, 30, 45 and 60 min after spirometry or a 6-min walk test, on two separate days in random order. Geometric mean FENO at baseline was 25.6 parts per billion (ppb) before spirometry and 23.5 ppb before exercise. A small drop of FENO to 24.2 and 23.7 ppb was found 5 and 15 min after spirometry (both p = 0.04). After exercise, FENO values showed a larger drop to 18.5 ppb after 5 min and 20.7 ppb after 15 min (p < 0.001; p = 0.004 respectively). Changes in FENO occurred after exercise irrespective of baseline FENO and values returned to baseline within 30 min. We conclude that both spirometry and exercise affect FENO in asthmatic children. As the changes after exercise may lead to erroneous interpretations, children should refrain from physical exercise during at least 30 min before FENO measurements.

Adolescent↗

Exhaled nitric oxide, total serum IgE and allergic sensitization in childhood asthma and allergic rhinitis.

Exhaled nitric oxide (eNO) levels are correlated with several markers of atopy and inflammatory activity in the airways, but the relationship between eNO and total serum IgE has not been fully elucidated in the context of allergic sensitization. The aim of this study was to investigate the relationship between eNO, total serum IgE and allergic sensitization in childhood asthma and allergic rhinitis. eNO levels, lung function, skin prick tests and total serum IgE were determined in 109 children (mean age, 10.4 yr) with mild intermittent asthma and in 41 children (mean age, 10.1 yr) with allergic rhinitis; 25 healthy non-atopic children were recruited as controls. eNO levels (median) were significantly higher in patients with asthma (22.7 p.p.b.) and in those with allergic rhinitis (15.3 p.p.b.) than in healthy controls (5.9 p.p.b.). Children with allergic asthma had higher eNO levels than children with allergic rhinitis. A significant positive correlation was found between eNO and total serum IgE (asthma, r = 0.42, p < 0.0001; allergic rhinitis, r = 0.31, p < 0.01), and between eNO and the number of positive skin prick tests (asthma, r = 0.31, p < 0.0001; allergic rhinitis, r = 0.39, p < 0.01). eNO levels were better correlated with total IgE than with the number of positive skin prick tests. This correlation was independent of allergic sensitization. High total serum IgE represents a specific and predictive marker of eNO increase in children with asthma or allergic rhinitis. This finding adds further support to the hypothesis that increased serum IgE could be a marker itself of airway inflammation in patients with allergic disease.

Adolescent↗

Daily ambulatory exhaled nitric oxide measurements in asthma.

Exhaled NO (FENO) is a non-invasive, validated marker for asthmatic airway inflammation. Recently, a new hand-held NO-analyzer has been developed which makes it possible to monitor FENO at home. We assessed feasibility and analyzed variability of daily FENO home measurements. Twenty-one asthmatics (mean age 14.5 yr; range 8-25 yr) participated. Nineteen used a stable dose of inhaled corticosteroids and all of them were in a stable clinical condition. FENO was measured twice daily for 14 consecutive days. Measurements and symptom scores were recorded on a smart card in the analyzer. Symptom score items included well-being, wheeze, activity, and nocturnal symptoms. Measurements showed a success rate of 93%. We found a significant diurnal variation in FENO with geometric mean morning levels 14% higher than evening levels (95% CI: 4%-25%; p = 0.013). Individual subjects showed marked fluctuation of FENO. The mean intrasubject coefficient of variation of FENO was 40% for morning and 36% for evening values. FENO and cumulative symptom scores did not correlate. Home FENO measurements are feasible, and offer the possibility to asses airway inflammation on a daily basis. Further study is needed to interpret and evaluate possible benefits of FENO home monitoring.

Adolescent↗

The promise and perils of exhaled breath condensates.

The exhaled breath condensate (EBC) approach provides a convenient and noninvasive approach for sampling the pulmonary epithelial lining fluid (ELF). Increased EBC concentrations of more than a dozen inflammatory markers and hydrogen ions have been reported in lung diseases associated with inflammation. However, the usefulness of EBC is compromised by uncertainties concerning the sources of the EBC droplets and by the extreme and variable dilution of ELF droplets with condensed water vapor ( approximately 20,000-fold). Reported increases in EBC concentrations may reflect proportionate increases in the total volume rather than the concentration of ELF droplets in the collected samples. Conclusions regarding ELF concentrations can only be made if this dilution is estimated with a dilutional indicator (e.g., conductivity of lyophilized EBC). In normal EBC samples, pH is effectively set by oral contamination with NH(3), and EBC pH cannot provide reliable information regarding ELF pH in normal subjects. Acidification of EBC observed in asthma and other conditions may reflect acidification of ELF, decreases in NH(3) added to the EBC, and/or the presence of gastric droplets in the EBC.

Breath Tests↗

Effects of mechanical ventilation at low lung volume on respiratory mechanics and nitric oxide exhalation in normal rabbits.

Lung mechanics, exhaled NO (NOe), and TNF-alpha in serum and bronchoalveolar lavage fluid were assessed in eight closed and eight open chest, normal anesthetized rabbits undergoing prolonged (3-4 h) mechanical ventilation (MV) at low volume with physiological tidal volumes (10 ml/kg). Relative to initial MV on positive end-expiratory pressure (PEEP), MV at low volume increased lung quasi-static elastance (+267 and +281%), airway (+471 and +382%) and viscolelastic resistance (+480 and +294%), and decreased NOe (-42 and -25%) in closed and open chest rabbits, respectively. After restoration of PEEP, viscoelastic resistance returned to control, whereas airway resistance remained elevated (+120 and +31%) and NOe low (-25 and -20%) in both groups of rabbits. Elastance remained elevated (+23%) only in closed-chest animals, being associated with interstitial pulmonary edema, as reflected by increased lung wet-to-dry weight ratio with normal albumin concentration in bronchoalveolar lavage fluid. In contrast, in 16 additional closed- and open-chest rabbits, there were no changes of lung mechanics or NOe after prolonged MV on PEEP only. At the end of prolonged MV, TNF-alpha was practically undetectable in serum, whereas its concentration in bronchoalveolar lavage fluid was low and similar in animals subjected or not subjected to ventilation at low volume (62 vs. 43 pg/ml). These results indicate that mechanical injury of peripheral airways due to their cyclic opening and closing during ventilation at low volume results in changes in lung mechanics and reduction in NOe and that these alterations are not mediated by a proinflammatory process, since this is expressed by TNF-alpha levels.

Animals↗

Quantitative assessment and repeatability of chlorine in exhaled breath condensate.

BACKGROUND: Airway condition is presumably reflected in epithelial lining fluid (ELF). Exhaled breath condensate (EBC) has been used as a surrogate marker of the composition of ELF. OBJECTIVES: This study aimed at assessing the technical repeatability of chlorine measurements in EBC and comparing two separate condensators (Ecoscreen and R Tube regarding recovery and repeatability. Furthermore, the association between condensate recoveries and variations in the airway status were scrutinized. METHODS: EBC was collected using two condensators from 10 healthy volunteers. In addition, 13 asthmatic patients produced EBC with or without an added resistance of 5 cm H2O (Res5), applied to the outflow tract of Ecoscreen. All tests were done in random order. Chlorine levels (analyzed by a coulometric technique) in EBC served as a tool for investigation. RESULTS: Chlorine was measurable in all samples. The coefficient of repeatability of chlorine measurements was <10%. Chlorine levels were higher in EBC obtained from R Tube (p < 0.001), and differences in recoveries and variability in chlorine levels were presumably related to technical differences in the condensators and not to the repeatability of chlorine measurements per se. Air-flow-dependent chlorine levels were obtained from healthy volunteers. Application of Res5, recruiting additional alveoli, resulted in increased recovery of the EBC volume, but not of chlorine, from those that had the most pronounced airway obstruction (p = 0.05). CONCLUSION: We conclude that by employing a sensitive analysis technique, chlorine is repeatedly measurable in EBC. We suggest that the bulk of chlorine in EBC originates from large airways and not from the alveolar area. Both condensators were comparable regarding repeatability but differed regarding chlorine recovery.

Adult↗

Decreased exhaled nitric oxide in pulmonary arterial hypertension: response to bosentan therapy.

RATIONALE: Decreased nitric oxide (NO) is considered an important pathogenetic mechanism in pulmonary arterial hypertension (PAH), but clear evidence is lacking. OBJECTIVES: We used multiple techniques to assess endogenous NO in 10 patients with untreated PAH (8 idiopathic and 2 anorexigen-associated PAH) and 12 control subjects. METHODS: After a nitrite/nitrate-restricted diet, NO metabolites (NOx) were assayed in 24-hour urine collections and exhaled NO (FE(NO)) determined at multiple expiratory flows. Analysis of the relation between FE(NO) and flow allowed derivation of three flow-independent parameters: airway wall concentration (C(W)), diffusing capacity (D(NO)), and alveolar concentration (C(A)). Seven patients underwent follow-up testing after 3 months of bosentan treatment. RESULTS: At baseline, FE(NO) was markedly decreased at the two lowest expiratory flows in PAH: 21 +/- 4 versus 36 +/- 4 ppb at 18 ml/second and 11 +/- 2 versus 17 +/- 2 ppb at 50 ml/second, for subjects with PAH and control subjects, respectively (p < 0.05). C(W) was 33 +/- 11 ppb in subjects with PAH versus 104 +/- 34 in control subjects (p = 0.04). Urinary NOx was also reduced in PAH (42 +/- 6 microM NOx/mM creatinine versus 62 +/- 7 in control subjects; p = 0.04). After bosentan, FE(NO), C(W), and urine NOx increased to control values (p < 0.05). Exclusion of the two anorexigen cases did not alter these results. CONCLUSIONS: FE(NO) at low expiratory flows was decreased in PAH due to reduced C(W). Bosentan reversed these abnormalities, suggesting that suppression of NO in PAH may have been caused by endothelin.

Adult↗

3p microsatellite alterations in exhaled breath condensate from patients with non-small cell lung cancer.

The still-high mortality for lung cancer urgently requires the availability of new, noninvasive diagnostic tools for use in early diagnosis and screening programs. Recently, exhaled breath condensate (EBC) has been proposed as a useful tool to obtain biological information on lung cancer disease. This study provides, for the first time, evidence that DNA alterations already described in lung cancer are detectable in EBC from patients with non-small cell lung cancer (NSCLC) and in healthy subjects. Thirty patients with histologic evidence of NSCLC and 20 healthy subjects were enrolled in the present study. All subjects had allelotyping analysis of DNA from EBC (EBC-DNA) and from whole blood (WB-DNA) of a selected panel of five microsatellites (D3S2338, D3S1266, D3S1300, D3S1304, D3S1289) located in chromosomal region 3p. Results from healthy subjects and subjects with cancer, and from EBC and WB, were compared. In addition, the relationships with smoking habit and clinicopathologic tumor features were considered. Microsatellite alterations (MAs) were found in 53% of EBC-DNA and in 10% of WB-DNA loci investigated in patients with NSCLC (p < 10(-6)); conversely, MAs were present only in 13% of EBC-DNA and in 2% of WB-DNA informative loci in healthy subjects. In patients with NSCLC, a direct association between number of MAs detected in EBC-DNA and tobacco consumption was observed. We conclude that EBC-DNA is highly sensitive in detecting MA information unique to patients with lung cancer. Furthermore, MA information seems to be directly related with tobacco consumption, and is potentially applicable to screening and early diagnostic programs for patients with NSCLC.

Aged↗

The effects of volatile salivary acids and bases on exhaled breath condensate pH.

RATIONALE: Recent studies have reported acidification of exhaled breath condensate (EBC) in inflammatory lung diseases. This phenomenon, designated "acidopnea," has been attributed to airway inflammation. OBJECTIVES: To determine whether salivary acids and bases can influence EBC pH in chronic obstructive pulmonary disease (COPD). METHODS: Measurements were made of pH, electrolytes, and volatile bases and acids in saliva and EBC equilibrated with air in 10 healthy subjects and 10 patients. RESULTS: The average EBC pH in COPD was reduced (normal, 7.24 +/- 0.24 SEM; range, 6.11-8.34; COPD, 6.67 +/- 0.18; range, 5.74-7.64; p = 0.079). EBCs were well buffered by NH(4)(+)/NH(3) and CO(2)/HCO(3)(-) in all but four patients, who had NH(4)(+) concentrations under 60 micromol/L, and acetate concentrations that approached or exceeded those of NH(4)(+). Saliva contained high concentrations of acetate (approximately 6,000 micromol/L) and NH(4)(+) (approximately 12,000 micromol/L). EBC acetate increased and EBC NH(4)(+) decreased when salivary pH was low, consistent with a salivary source for these volatile constituents. Nonvolatile acids did not play a significant role in determining pH of condensates because of extreme dilution of respiratory droplets by water vapor (approximately 1:12,000). Transfer of both acetic acid and NH(3) from the saliva to the EBC was in the gas phase rather than droplets. CONCLUSIONS: EBC acidification in COPD can be affected by the balance of volatile salivary acids and bases, suggesting that EBC pH may not be a reliable marker of airway acidification. Salivary acidification may play an important role in acidopnea.

Acetic Acid↗

Optimising hydrogen peroxide measurement in exhaled breath condensate.

BACKGROUND: Exhaled breath condensate (EBC) analysis has been proposed as a non-invasive method of assessing airway pathology. A number of substances, including hydrogen peroxide (H2O2), have been measured in EBC, without adequate published details of validation and optimisation. OBJECTIVES: To explore factors that affect accurate quantitation of H2O2 in EBC. MATERIALS AND METHODS: H2O2 was measured in EBC samples using fluorometry with 4-hydroxyphenylacetic acid. A number of factors that might alter quantitation were studied including pH and buffering conditions, reagent storage, and assay temperature. RESULTS: Standard curve slope was significantly altered by pH, leading to a potential difference in H2O2 quantification of up to 42%. These differences were resolved by increasing the buffering capacity of the reaction mix. H2O2 added to EBC remained stable for 1 h when stored on ice. The assay was unaffected by freezing assay reagents. The limit of detection for H2O2 ranged from 3.4 nM to 8.8 nM depending on the buffer used. CONCLUSIONS: The reagents required for this assay can be stored for several months allowing valuable consistency in longitudinal studies. The quantitation of H2O2 in EBC is pH-dependent but increasing assay buffering reduces this effect. Sensitive reproducible quantitation of H2O2 in EBC requires rigorous optimisation.

Adult↗

Alterations of exhaled nitric oxide in pre-term infants with chronic lung disease.

Animal models suggest that reduced nitric oxide (NO) synthase activity results in lower values of exhaled NO (eNO) present at birth in those individuals who are going to develop chronic lung disease of infancy (CLDI). Online tidal eNO was measured in 39 unsedated pre-term infants with CLDI (mean gestational age (GA) 27.3 weeks) in comparison with 23 healthy pre-term (31.6 weeks) and 127 term infants (39.9 weeks) at 44 weeks post-conceptional age, thus after the main inflammatory response. NO output (NO output (V'(NO)) = eNO x flow) was calculated to account for tidal- flow-related changes. Sex, maternal atopic disease and environmental factors (smoking, caffeine) were controlled for. The mean eNO was not different (14.9 ppb in all groups) but V'(NO) was lower in CLDI compared with healthy term infants (0.52 versus 0.63 nL x s(-1)). Values for healthy pre-term infants were between these two groups (0.58 nL x s(-1)). Within all pre-term infants (n = 62), V'(NO) was reduced in infants with low GA, high clinical risk index for babies scores and longer duration of oxygen therapy but not associated with post-natal factors, such as ventilation or corticosteroid treatment. After accounting for flow, the lower nitric oxide output in premature infants with chronic lung disease of infancy is consistent with the hypothesis of nitric oxide metabolism being involved in chronic lung disease of infancy.

Breath Tests↗

Exhaled nitric oxide from lung periphery is increased in COPD.

Single constant flow exhaled nitric oxide (eNO) cannot distinguish between the sources of NO. The present study measured eNO at multiple expired flows (MEFeNO) to partition NO into alveolar (Calv,NO) and bronchial (Jaw,NO) fractions to investigate peripheral lung contribution to eNO in chronic obstructive lung disease (COPD). MEFeNO were made in 81 subjects including 18 nonsmokers, 16 smokers and 47 COPD patients of different severity by the classification of the Global Initiative for Chronic Obstructive Lung Disease (GOLD): 0 (n = 14), 1 (n = 7), 2 (n = 11), 3 (n = 8) and 4 (n = 7). COPD severity was correlated with an increased Calv,NO regardless of the patient's smoking habit or current treatment. The levels of Calv,NO (in ppb) were 1.4+/-0.09 in nonsmokers, 2.1+/-0.1 in smokers categorised as GOLD stage 0 (smokers-GOLD0), 3.3+/-0.18 in GOLD1-2 and 3.4+/-0.1 in GOLD3-4. Jaw,NO levels (pL x s(-1)) were higher in nonsmokers than smokers-GOLD0 (716.2+/-33.3 versus 464.7+/-41.8), GOLD3-4 (609.4+/-71). Diffusion of NO in the airways (Daw,NO pL x ppb(-1) s(-1)) was higher (p<0.05) in GOLD3-4 than in nonsmokers (15+/-1.2 versus 11+/-0.5) and smokers-GOLD0 (11.6+/-0.5). MEFeNO measurements were reproducible, free from day-to-day and diurnal variation and were not affected by bronchodilators. In conclusion, chronic obstructive pulmonary disease is associated with elevated alveolar nitric oxide. Measurements of nitric oxide at multiple expired flows may be useful in monitoring inflammation and progression of chronic obstructive pulmonary disease, and the response to anti-inflammatory treatment.

Adult↗

Exhaled volatile organic compounds in patients with non-small cell lung cancer: cross sectional and nested short-term follow-up study.

BACKGROUND: Non-invasive diagnostic strategies aimed at identifying biomarkers of lung cancer are of great interest for early cancer detection. The aim of this study was to set up a new method for identifying and quantifying volatile organic compounds (VOCs) in exhaled air of patients with non-small cells lung cancer (NSCLC), by comparing the levels with those obtained from healthy smokers and non-smokers, and patients with chronic obstructive pulmonary disease. The VOC collection and analyses were repeated three weeks after the NSCLC patients underwent lung surgery. METHODS: The subjects' breath was collected in a Teflon bulb that traps the last portion of single slow vital capacity. The 13 VOCs selected for this study were concentrated using a solid phase microextraction technique and subsequently analysed by means of gas cromatography/mass spectrometry. RESULTS: The levels of the selected VOCs ranged from 10(-12) M for styrene to 10(-9) M for isoprene. None of VOCs alone discriminated the study groups, and so it was not possible to identify one single chemical compound as a specific lung cancer biomarker. However, multinomial logistic regression analysis showed that VOC profile can correctly classify about 80% of cases. Only isoprene and decane levels significantly decreased after surgery. CONCLUSION: As the combination of the 13 VOCs allowed the correct classification of the cases into groups, together with conventional diagnostic approaches, VOC analysis could be used as a complementary test for the early diagnosis of lung cancer. Its possible use in the follow-up of operated patients cannot be recommended on the basis of the results of our short-term nested study.

Aged↗

Exhaled breath condensate cysteinyl leukotrienes and airway remodeling in childhood asthma: a pilot study.

BACKGROUND: It has been suggested that cysteinyl leukotrienes (cysLTs) play an important role in airway remodeling. Previous reports have indicated that cysLTs augment human airway smooth muscle cell proliferation. Recently, cysLTs have been measured in exhaled breath condensate (EBC). The aim of this study was to evaluate the relationship between cysLTs in EBC and another marker of airway remodeling, reticular basement membrane (RBM) thickening, in endobronchial biopsies in children. METHODS: 29 children, aged 4-15 years, with moderate to severe persistent asthma, who underwent bronchoscopy as part of their clinical assessment, were included. Subjects underwent spirometry and EBC collection for cysLTs analysis, followed by bronchoscopy and endobronchial biopsy within 24 hours. RESULTS: EBC cysLTs were significantly lower in asthmatic children who were treated with montelukast than in those who were not (median (interquartile range) 36.62 (22.60-101.05) versus 249.1 (74.21-526.36) pg/ml, p = 0.004). There was a significant relationship between EBC cysLTs and RBM thickness in the subgroup of children who were not treated with montelukast (n = 13, r = 0.75, p = 0.003). CONCLUSION: EBC cysLTs appear to be associated with RBM thickening in asthma.

Acetates↗

Exhaled nitric oxide differentiates airway diseases in the first two years of life.

Fractional exhaled nitric oxide (FE(NO)) levels are increased in children and adults with asthma, whereas low levels have been found in cystic fibrosis and primary ciliary dyskinesia. The aim of this study was to investigate whether FE(NO) measurements could distinguish between children below the age of 2 with different airway diseases. FE(NO) measurements were performed in 118 infants aged between 4.6 and 25.2 mo: 74 infants with recurrent wheezing (RW), 24 with bronchopulmonary dysplasia (BPD), and 20 with cystic fibrosis (CF). FE(NO) was measured also in 100 healthy controls aged between 1.1 and 7.7 mo. Geometric mean (95% confidence interval) FE(NO) values were 10.4 (9.1-12.0) parts per billion (ppb) in healthy infants, 18.6 (15.6-22.2) ppb in wheezy infants, 11.7 (8.2-16.8) ppb in BPD infants and 5.9 (3.4-10.1) ppb in CF infants. FE(NO) in wheezers was higher than in controls, BPD, and CF (p = 0.009, p = 0.038, and p < 0.001, respectively). Atopic wheezers showed higher FE(NO) than nonatopic wheezers (p = 0.04). CF infants had lower FE(NO) than healthy controls and BPD infants (p = 0.003 and p = 0.043, respectively). FE(NO) values in BPD and control infants were not different. We conclude that FE(NO) is helpful to differentiate various airway diseases already in the first 2 y of life.

Diagnosis, Differential↗