Voltage-dependent reversal of anodic galvanotaxis in Nyctotherus ovalis.

Aerobic and anaerobic ciliates swim towards the cathode when they are exposed to a constant DC field. Nyctotherus ovalis from the intestinal tract of cockroaches exhibits a different galvanotactic response: at low strength of the DC field the ciliates orient towards the anode whereas DC fields above 2-4 V/cm cause cathodic swimming. This reversal of the galvanotactic response is not due to backward swimming. Rather the ciliates turn around and orient to the cathode with their anterior pole. Exposure to various cations, chelators, and Ca(2+)-channel inhibitors suggests that Ca(2+)-channels similar to the "long lasting" Ca(2+)-channels of vertebrates are involved in the voltage-dependent anodic galvanotaxis. Evidence is presented that host-dependent epigenetic factors can influence the voltage-threshold for the switch from anodic to cathodic swimming.

Animals↗

Electric and magnetic stimulation of human motor cortex: surface EMG and single motor unit responses.

1. The effects of different forms of brain stimulation on the discharge pattern of single motor units were examined using the post-stimulus time histogram (PSTH) technique and by recording the compound surface electromyographic (EMG) responses in the first dorsal interosseous (FDI) muscle. Electrical and magnetic methods were used to stimulate the brain through the intact scalp of seven normal subjects. Electrical stimuli were applied either with the anode over the lateral central scalp and the cathode at the vertex (anodal stimulation) or with the anode at the vertex and the cathode lateral (cathodal stimulation). Magnetic stimulation used a 9 cm diameter coil centred at the vertex; current in the coil flowed either clockwise or anticlockwise when viewed from above. 2. Supramotor threshold stimuli produced one or more narrow (less than 2 ms) peaks of increased firing in the PSTH of all thirty-two units studied. Anodal stimulation always produced an early peak. The latencies of the peaks produced by other forms of stimulation, or by high intensities of anodal stimulation, were grouped into four time bands relative to this early peak, at intervals of -0.5 to 0.5, 1-2, 2.5-3.5 and 4-5.5 ms later. Peaks occurring within these intervals are referred to as P0 (the earliest anodal), P1, P2 and P3 respectively. 3. At threshold, anodal stimulation evoked only the P0 peak; at higher intensities, the P2 or more commonly the P3 peak also was recruited. The size of the P0 peak appeared to saturate at high intensities. 4. In five of six subjects, cathodal stimulation behaved like anodal stimulation, except that there was a lower threshold for recruitment of the P2 or P3 peak relative to that of the P0 peak. In the other subject, the P3 peak was recruited before the P0 peak. 5. Anticlockwise magnetic [corrected] stimulation, at threshold, often produced several peaks. These always included a P1 peak, and usually a P3 peak. A P0 peak in the PSTH was never produced by an anticlockwise stimulation [corrected] at intensities which we could explore with the technique. 6. Clockwise magnetic [corrected] stimulation never recruited a P1 peak; in most subjects a P3 peak was recruited first and at higher intensities was accompanied by P0 or P2 peaks. 7. On most occasions when more than one peak was observed in a PSTH, the unit fired in only one of the preferred intervals after each shock. However, double firing was seen in five units when high intensities of stimulation were used.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

Break excitation alone does not explain the delay and amplitude of anodal current-induced vasodilatation in human skin.

In iontophoresis experiments, a 'non-specific' current-induced vasodilatation interferes with the effects of the diffused drugs. This current-induced vasodilatation is assumed to rely on an axon reflex due to excitation of cutaneous nociceptors and is weaker and delayed at the anode as compared to the cathode. We analysed whether these anodal specificities could result from a break excitation of nociceptors. Break excitation is the generation of action potentials at the end of a square anodal DC current application, which are generally weaker than those observed at the onset of a same application at the cathode. In eight healthy volunteers, we studied forearm cutaneous laser Doppler flow (LDF) responses to: (1) anodal and cathodal 100 microA current applications of 1, 2, 3, 4 or 5 min; (2) 100 microA anodal applications of 3 min with a progressive ending over 100 s (total charge 23 mC); these were compared to square-ended 100 microA anodal applications of the same total charge (23 mC) or duration (3 min); (3) a 4 min 100 microA anodal application with a 333 msec break at half time. Results (mean +/- S.D.) are expressed as percentage of heat-induced maximal vasodilatation (%MVD). Onset (T(vd)) and amplitude (LDF(peak)) of vasodilatation were determined. We observed that: T(vd) was linearly related to the duration of current application at the anode (slope = 1.01, r(2) = 0.99, P < 0.0001) but not at the cathode (slope = 0.03, r(2) = 0.02, n.s.). Progressive ending of anodal current did not decrease LDF(peak) (63.3 +/- 24.6 %MVD) as compared to square-ending of current application of the same duration (36.9 +/- 22.2 %MVD) or the same total charge (57.1 +/- 23.5 %MVD). A transient break of anodal current did not allow for the vasodilatation to develop until current was permanently stopped. We conclude that, during iontophoresis, anodal break excitation alone cannot account for the delay and amplitude of the vascular response.

Adult↗

A short latency vestibulomasseteric reflex evoked by electrical stimulation over the mastoid in healthy humans.

We describe EMG responses recorded in active masseter muscles following unilateral and bilateral electrical vestibular stimulation (EVS, current pulses of 5 mA intensity, 2 ms duration, 3 Hz frequency). Averaged responses in unrectified masseter EMG induced by unilateral EVS were examined in 16 healthy subjects; effects induced by bilateral (transmastoid) stimulation were studied in 10 subjects. Results showed that unilateral as well as bilateral EVS induces bilaterally a clear biphasic response (onset latency ranging from 7.2 to 8.8 ms), that is of equal amplitude and latency contra- and ipsilateral to the stimulation site. In all subjects, unilateral cathodal stimulation induced a positive-negative response termed p11/n15 according to its mean peak latency; the anodal stimulation induced a response of opposite polarity (n11/p15) in 11/16 subjects. Cathodal responses were significantly larger than anodal responses. Bilateral stimulation induced a p11/n15 response significantly larger than that induced by the unilateral cathodal stimulation. Recordings from single motor units showed that responses to cathodal stimulation corresponded to a brief (2-4 ms) silent period in motor unit discharge rate. The magnitude of EVS-induced masseter response was linearly related to current intensity and scaled with the mean level of EMG activity. The size of the p11/n15 response was asymmetrically modulated when subjects were tilted on both sides; in contrast head rotation did not exert any influence. Control experiments excluded a possible role of cutaneous receptors in generating the masseter response. We conclude that transmastoid electrical stimulation evokes vestibulomasseteric reflexes in healthy humans at latencies consistent with a di-trisynaptic pathway.

Adult↗

Modulating parameters of excitability during and after transcranial direct current stimulation of the human motor cortex.

Weak transcranial direct current stimulation (tDCS) of the human motor cortex results in excitability shifts which occur during and after stimulation. These excitability shifts are polarity-specific with anodal tDCS enhancing excitability, and cathodal reducing it. To explore the origin of this excitability modulation in more detail, we measured the input-output curve and motor thresholds as global parameters of cortico-spinal excitability, and determined intracortical inhibition and facilitation, as well as facilitatory indirect wave (I-wave) interactions. Measurements were performed during short-term tDCS, which elicits no after-effects, and during other tDCS protocols which do elicit short- and long-lasting after-effects. Resting and active motor thresholds remained stable during and after tDCS. The slope of the input-output curve was increased by anodal tDCS and decreased by cathodal tDCS. Anodal tDCS of the primary motor cortex reduced intracortical inhibition and enhanced facilitation after tDCS but not during tDCS. Cathodal tDCS reduced facilitation during, and additionally increased inhibition after its administration. During tDCS, I-wave facilitation was not influenced but, for the after-effects, anodal tDCS increased I-wave facilitation, while cathodal tDCS had only minor effects. These results suggest that the effect of tDCS on cortico-spinal excitability during a short period of stimulation (which does not induce after-effects) primarily depends on subthreshold resting membrane potential changes, which are able to modulate the input-output curve, but not motor thresholds. In contrast, the after-effects of tDCS are due to shifts in intracortical inhibition and facilitation, and at least partly also to facilitatory I-wave interaction, which is controlled by synaptic activity.

Adult↗

Energetic Iron(VI) chemistry: the super-iron battery

Higher capacity batteries based on an unusual stabilized iron(VI) chemistry are presented. The storage capacities of alkaline and metal hydride batteries are largely cathode limited, and both use a potassium hydroxide electrolyte. The new batteries are compatible with the alkaline and metal hydride battery anodes but have higher cathode capacity and are based on available, benign materials. Iron(VI/III) cathodes can use low-solubility K(2)FeO(4) and BaFeO(4) salts with respective capacities of 406 and 313 milliampere-hours per gram. Super-iron batteries have a 50 percent energy advantage compared to conventional alkaline batteries. A cell with an iron(VI) cathode and a metal hydride anode is significantly (75 percent) rechargeable.

Journal Article↗

Percutaneous electrical stimulation of lumbosacral roots in man.

High voltage percutaneous electrical stimulation over the lumbosacral spinal column was used to assess conduction in the cauda equina of 13 normal subjects. Electromyographic activity elicited by such stimulation was recorded from various muscles of the lower limbs. The stimulating cathode was placed over the spinous process of each vertebral body and the anode kept on the iliac crest contralateral to the studied limb. Shifting the cathode in a rostro-caudal direction shortened the response latency in quadriceps, tibialis anterior and extensor digitorum brevis muscles. At moderate intensities (60% maximum), this occurred abruptly when the cathode was placed at levels corresponding to the exit sites from the spinal canal of the roots innervating these muscles. At these intensities, the size of the response in each muscle was largest when the cathode was placed over the conus medullaris or at or below the exit of the motor roots from the spine. Latencies were always equal to or shorter than those obtained with F-wave measurements, suggesting that peripheral motor axons, rather than intraspinal structures were activated by the stimulus. Collision experiments demonstrated that activation occurred at two sites: near the spinal cord and at the root exit site in the vertebral foramina. Recordings made from soleus indicated that larger diameter proprioceptive afferent fibres also could be activated. This technique might have useful clinical applications in the study of both proximal and distal lesions of the cauda equina and provide a non-invasive method of localising such lesions electrophysiologically.

Adult↗

Mechanisms of make and break excitation revisited: paradoxical break excitation during diastolic stimulation.

Onset and termination of electric stimulation may result in "make" and "break" excitation of the heart tissue. Wikswo et al. (30) explained both types of stimulations by virtual electrode polarization. Make excitation propagates from depolarized regions (virtual cathodes). Break excitation propagates from hyperpolarized regions (virtual anodes). However, these studies were limited to strong stimulus intensities. We examined excitation during weak near-threshold diastolic stimulation. We optically mapped electrical activity from a 4 x 4-mm area of epicardium of Langendorff-perfused rabbit hearts (n = 12) around the pacing electrode in the presence (n = 12) and absence (n = 2) of 15 mM 2,3-butanedione monoxime. Anodal and cathodal 2-ms stimuli of various intensities were applied. We imaged an excitation wavefront with 528-micros resolution. We found that strong stimuli (x5 threshold) result in make excitation, starting from the virtual cathodes. In contrast, near-threshold stimulation resulted in break excitation, originating from the virtual anodes. Characteristic biphasic upstrokes in the virtual cathode area were observed. Break and make excitation represent two extreme cases of near-threshold and far-above-threshold stimulations, respectively. Both mechanisms are likely to contribute during intermediate clinically relevant strengths.

Action Potentials↗

Examination of stimulation mechanism and strength-interval curve in cardiac tissue.

Understanding the basic mechanisms of excitability through the cardiac cycle is critical to both the development of new implantable cardiac stimulators and improvement of the pacing protocol. Although numerous works have examined excitability in different phases of the cardiac cycle, no systematic experimental research has been conducted to elucidate the correlation among the virtual electrode polarization pattern, stimulation mechanism, and excitability under unipolar cathodal and anodal stimulation. We used a high-resolution imaging system to study the spatial and temporal stimulation patterns in 20 Langendorff-perfused rabbit hearts. The potential-sensitive dye di-4-ANEPPS was utilized to record the electrical activity using epifluorescence. We delivered S1-S2 unipolar point stimuli with durations of 2-20 ms. The anodal S-I curves displayed a more complex shape in comparison with the cathodal curves. The descent from refractoriness for anodal stimulation was extremely steep, and a local minimum was clearly observed. The subsequent ascending limb had either a dome-shaped maximum or was flattened, appearing as a plateau. The cathodal S-I curves were smoother, closer to a hyperbolic shape. The transition of the stimulation mechanism from break to make always coincided with the final descending phase of both anodal and cathodal S-I curves. The transition is attributed to the bidomain properties of cardiac tissue. The effective refractory period was longer when negative stimuli were delivered than for positive stimulation. Our spatial and temporal analyses of the stimulation patterns near refractoriness show always an excitation mechanism mediated by damped wave propagation after S2 termination.

Animals↗

An electrode for PN2O and PO2 analysis in blood and gas.

The development of a new polarographic sensor for measuring simultaneously both N2O and O2, in either gas or blood, is described. The cathode is made of silver, and it is shown that silver deposition on normal platinum or gold cathode electrodes can result in an enhancement of a PO2 signal, when measured in the presence of nitrous oxide. Silver can be deposited on the cathode by means of Ag+ ions diffusing through the electrolyte from an Ag/AgCl reference electrode. The use of an Ag cathode enables both O2 and N2O signals to be measured.

Blood Gas Analysis↗

Mechanisms of myocardial capture and temporal excitable gap during spiral wave reentry in a bidomain model.

BACKGROUND: Recent studies have demonstrated that regional capture during cardiac fibrillation is associated with an elevated capture threshold. It is typically assumed that the temporal excitable gap (capture window) during fibrillation reflects the size of the spatial excitable gap (excitable tissue between fibrillation waves). Because capture threshold is high, virtual electrode polarization is expected to be involved in the process. However, little is known about the underlying mechanisms of myocardial capture during fibrillation. METHODS AND RESULTS: To clarify these issues, we conducted altogether 3168 simulations of single spiral wave capture in a bidomain sheet. Unipolar stimuli of strengths 4, 8, 16, and 24 mA and 2-ms duration were delivered at 99 locations in the sheet. We found that cathode-break rather than cathode-make excitation was the dominant mechanism of myocardial capture. When the stimulation site was located diagonally with respect to the core (upper left or lower right if the spiral wave rotates counterclockwise), the cathode-break excitation easily invaded the spatial excitable gap and resulted in a successful capture as a result of the formation of virtual anodes in the direction of the myocardial fibers. Thus, the spatial distribution of the temporal excitable gap did not reflect the spatial excitable gap. CONCLUSIONS: The areas exhibiting wide temporal excitable gaps were areas in which the cathode-break excitation wave fronts easily invaded the spatial excitable gap via the virtual anodes. This study provides mechanistic insight into myocardial capture.

Atrial Fibrillation↗

Comparison of bipolar and unipolar programmed electrical stimulation for the initiation of ventricular arrhythmias: significance of anodal excitation during bipolar stimulation.

To determine if anodal excitation during bipolar stimulation facilitates the initiation of sustained monomorphic ventricular tachycardia, nonsustained polymorphic ventricular tachycardia, or repetitive ventricular responses, both bipolar and cathodal unipolar programmed ventricular stimulation with one to three extrastimuli delivered during ventricular pacing at two rates from the right ventricular apex were performed in 28 patients evaluated for spontaneous sustained ventricular tachycardia or ventricular fibrillation (11 patients), nonsustained tachycardia (eight patients), or syncope (nine patients). In 25 patients a hexapolar pacing catheter was used to record local endocardial activation times adjacent to the cathode and anode and ventricular excitation during bipolar stimulation was defined as predominantly anodal, cathodal, or simultaneous at both anode and cathode. When bipolar and unipolar stimulation were compared there was no difference in the incidence of initiating sustained monomorphic ventricular tachycardia (57% vs 57%), nonsustained polymorphic ventricular tachycardia (14% vs 14%), or repetitive ventricular responses (21% vs 21%), although the response to bipolar vs unipolar stimulation was not concordant in every patient. Evidence of anodal excitation was observed in 11 (44%) patients but did not indicate increased risk of initiation of any ventricular arrhythmia, despite the fact that it was associated with shortening of the ventricular effective refractory period by 5.2 +/- 8.7 msec (p less than .05) during bipolar as opposed to unipolar stimulation. We conclude that unipolar and bipolar stimulation produce a similar incidence of initiation of arrhythmia, despite the frequent occurrence of anodal excitation during bipolar stimulation. Thus, the risk of initiation of nonspecific ventricular arrhythmias during programmed stimulation is unlikely to be reduced by the use of unipolar stimulation.

Adolescent↗

Transmembrane voltage changes during unipolar stimulation of rabbit ventricle.

This study tested the prediction of bidomain models that unipolar stimulation of anisotropic myocardium produces transmembrane voltage changes (delta VmS) of opposite signs away from the electrode on perpendicular axes. Stimulation with a strength of 0.1 to 40 mA was applied from a point electrode on the left or right ventricle of isolated perfused rabbit hearts at 37 degrees C to 38 degrees C stained with the potentiometric dye di-4-ANEPPS. A laser scanner system recorded Vm-sensitive fluorescence at 63 spots in an 8 x 8-mm region around the electrode. Cathodal stimulation in the refractory period produced regions of -delta Vm 1 to 5 mm away from the electrode on an axis oriented parallel to the fast propagation axis to within 1.8 +/- 11 degrees (P > or = .7 for difference versus zero, n = 7). Recording spots in these regions underwent + delta Vm when anodal stimulation was used. At recording spots on the slow propagation axis, cathodal stimulation produced + delta Vm and anodal stimulation produced -delta Vm. During diastolic stimulation, early excitation occurred near the electrode for cathodal stimulation or on the fast propagation axis as fas as 2.8 +/- 1 mm away from the electrode for anodal stimulation. A "dog-bone" region of + delta Vm that included tissue near and away from the electrode on the slow propagation axis occurred when cathodal stimulation was given in diastole. Regions of + delta Vm occurred away from the electrode on the fast propagation axis when anodal stimulation was given in diastole. Thus, delta Vm differs in regions along and across myocardial fibers, indicating that delta Vm depends on anisotropic bidomain properties. Sites of early excitation are those where + delta Vm occurs, indicating that membrane channel excitation depends on the distribution of delta Vm.

Animals↗

Direct current stimulation over V5 enhances visuomotor coordination by improving motion perception in humans.

The primary aim of this study was to determine the extent to which human MT+/V5, an extrastriate visual area known to mediate motion processing, is involved in visuomotor coordination. To pursue this we increased or decreased the excitability of MT+/V5, primary motor, and primary visual cortex by the application of 7 min of anodal and cathodal transcranial direct current stimulation (tDCS) in healthy human subjects while they were performing a visuomotor tracking task involving hand movements. The percentage of correct tracking movements increased specifically during and immediately after cathodal stimulation, which decreases cortical excitability, only when V5 was stimulated. None of the other stimulation conditions affected visuomotor performance. We propose that the improvement in performance caused by cathodal tDCS of V5 is due to a focusing effect on to the complex motion perception conditions involved in this task. This hypothesis was proven by additional experiments: Testing simple and complex motion perception in dot kinetograms, we found that a diminution in excitability induced by cathodal stimulation improved the subject's perception of the direction of the coherent motion only if this was presented among random dots (complex motion perception), and worsened it if only one motion direction was presented (simple movement perception). Our data suggest that area V5 is critically involved in complex motion perception and identification processes important for visuomotor coordination. The results also raise the possibility of the usefulness of tDCS in rehabilitation strategies for neurological patients with visuomotor disorders.

Adult↗

HGF, MAPK, and a small physiological electric field interact during corneal epithelial cell migration.

PURPOSE: To investigate the effects of hepatocyte growth factor (HGF) and a small applied electric field (EF) on corneal epithelial cell (CEC) migration. METHODS: Primary cultures of bovine CECs were exposed to an EF (25-250 mV/mm) in the presence or absence of HGF (100 ng/mL). The rate and directionality of CEC migration were quantified. The expression of HGF receptors (HGFRs), p42/44 mitogen-activated protein kinase (MAPK) and the time-course of activation of p42/44 MAPK were investigated by confocal microscopy and Western blot analysis. RESULTS: CECs migrated significantly faster in the presence of an EF, HGF, or HGF and an EF combined. The distribution of HGFRs was intracellular and in the presence of an EF was concentrated in the cathode-facing side. This EF-induced asymmetrical accumulation of HGFRs correlated with the direction of CEC migration. The application of HGF or an EF led to the activation of the MAPK signaling pathway and in the presence of an EF, activation of MAPK was greater in the cathode-facing half of the CECs. Inhibition of the MAPK signaling pathway by PD98059 (100 micro M) reduced the ability of HGF and an EF to enhance the rate of CEC migration, but did not alter EF-induced cathodal directionality. CONCLUSIONS: These data suggest that both HGF and an EF augment the rate of CEC migration through activation of p42/44 MAPK. Moreover, EF-induced redistribution of HGFRs and asymmetry of MAPK signaling, although not instrumental in directing CEC migration cathodally, may be important for the signaling and maintenance of migration.

Animals↗

Orientation and directed migration of cultured corneal epithelial cells in small electric fields are serum dependent.

Reorientation and migration of cultured bovine corneal epithelial cells (CECs) in an electric field were studied. Electric field application was designed to model the laterally directed, steady direct current electric fields which arise in an injured corneal epithelium. Single cells cultured in media containing 10% foetal bovine serum showed significant galvanotropism, reorienting to lie perpendicular to electric field vector with a threshold field strength of less than 100 mV/mm. Cells cultured in serum-free medium showed no reorientation until 250 mV/mm. Addition of EGF, bFGF or TGF-beta 1 singly or in combination to serum free medium significantly restored the reorientation response at low field strengths. Both the mean translocation rate and directedness of cell migration were serum dependent. Cultured in medium with serum or serum plus added EGF, single cells showed obvious cathodal migration at 100 mV/mm. Increasing electric field strength enhanced the cathodal directedness of single cell migration. Supplementing serum free medium with growth factors restored the cathodal directed migration of single cells and highest directedness was found for the combination of EGF and TGF-beta 1. Corneal epithelial sheets also migrated towards the cathode in electric fields. Serum or individual growth factors stimulated CEC motility (randomly directed). Applied fields did not further augment migration rates but added a vector to stimulated migration. Electric fields which are present in wounded cornea interact with other environmental factors and may impinge on CECs migration during wound healing. Therapies which combine the application of growth factors and electric fields may be useful clinically.

Animals↗

"Anode heel effect" on patient dose in lumbar spine radiography.

Appropriate use of the "anode heel effect" of the output beam from an X-ray tube can reduce the effective dose to patients in some common radiological examinations. We investigated the variation in radiation intensity across the X-ray beam caused by the anode heel effect, and quantified the difference in absorbed dose to critical organs resulting from lumbar spine X-ray projections carried out with the two possible orientations of the patient along the tube axis (cathode to anode). A Rando phantom and some high sensitivity thermoluminescent dosemeters (TLDs) (LiF:Mg,Cu,P) were used. With the tube axis horizontal, radiation intensity profiles, parallel and perpendicular to the axis, were measured. Lumbar spine radiographs were recorded using the Rando phantom in the standard anteroposterior (AP) and lateral projections. TLD pellets were used to measure the absorbed radiation dose at various sites corresponding to critical organ tissues (ovaries, testes, breasts, thyroid and lens). Each set of projections was recorded in two phantom orientations, first with the phantom head placed towards the cathode end of the X-ray tube, and then in the reverse direction. From the radiation intensity profile of the incident X-ray beam, the "cathode end" to "anode end" air dose ratio was found to be 1.8. In lumbar spine radiography, with the phantom head placed towards the anode end of the X-ray tube, the ovaries and testes received an average dose 17% and 12% higher, respectively, in the lateral projection, and 16% and 27% higher, respectively, in the AP projection, than those obtained in the reverse "patient" orientation. These results indicate that patients (particularly females) should always be positioned with the head placed towards the cathode end of the X-ray tube for lumbar spine radiography to achieve significant dose reductions.

Breast↗

In vitro and in vivo stability of electrode potentials in needle-type glucose sensors. Influence of needle material.

Enzymatic glucose sensors are based on the amperometric detection of an oxidable species generated during the oxidation of glucose by glucose oxidase. This measurement usually requires a working electrode (anode), an auxiliary electrode (cathode), and a reference electrode, the function of the latter being to keep constant the working potential of the anode, which is responsible for current generation. However, in the needle-type glucose sensors proposed so far, the reference electrode is missing, and its function is performed by the auxiliary electrode. We investigated, in vitro and in vivo in rats, the ability of several cathode-needle materials to behave as a reference electrode in two-electrode glucose sensors, i.e., to present a stable auxiliary electrode potential. In vitro, when glucose concentration was raised from 0 to 30 mM, the auxiliary potential of both gold- and silver-coated sensors presented a cathodic drift, whereas that of silver/silver chloride-coated sensors remained stable. In vivo, during insulin-induced hypoglycemia (5.9-2.4 mM), the auxiliary potentials of all sensors remained stable, whereas during glucose infusion (mean blood glucose concentration 11.2 mM), the auxiliary potentials of both gold- and silver-coated sensors presented an anodic drift, whereas those of silver/silver chloride-coated sensors remained stable. We also indirectly quantified the changes in sensor response induced by variations in the working potential in vitro and in vivo, simulating those that might be produced by a drift in the auxiliary potential. Such changes in the working potential could bring about a 30% unspecific variation in sensor response. We conclude that improvements in sensor analytical characteristics should be obtained with silver/silver-chloride-coated cathodes.

Animals↗