Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Accuracy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49Linked to original sources

Multidetector row CT angiography of the abdominal aorta and lower extremities in patients with peripheral arterial occlusive disease: diagnostic accuracy and interobserver agreement.

PURPOSE: To evaluate the accuracy of four channel multidetector row CT angiography (MDCTA) of the abdominal aorta and lower extremities arteries compared with digital subtraction angiography (DSA). MATERIALS AND METHODS: In our prospective study 42 patients with peripheral vascular occlusive disease (27 M, 15 F, age range 40-79 years) underwent MDCTA and DSA within 5 days. Images were blindly interpreted by two radiologists. Maximum intensity projections (MIP), multiplanar (MPR) reformations, three-dimensional (3D) reconstructions as well as axial images were available for analysis of MDCTA. DSA were analyzed on hard copies. RESULTS: Overall sensitivity and specificity of MDCTA were 93 and 95%, respectively, with positive and negative predictive values of 90 and 97%. Overall diagnostic accuracy was 94%. Normal arterial segments and 100% occlusions were correctly identified in all cases by MDCTA. Moderately stenotic segments interpretation in the calves appeared to be more controversial, but no statistical difference in accuracy of MDCTA in the infrapopliteal district arteries was noted with respect to accuracy in the more proximal arterial bed. Good to excellent interobserver and intraobserver agreement were observed, with k values greater than 0.80. CONCLUSIONS: MDCTA of the abdominal aorta and lower extremities is an accurate imaging modality in clinical practice when compared with DSA.

Adult↗

The diagnostic accuracy of computed tomography angiography for traumatic or atherosclerotic lesions of the carotid and vertebral arteries: a systematic review.

INTRODUCTION: Helical computed tomography angiography (CTA) has become an established technique for evaluating atherosclerosis of the cerebrovascular arteries. However, the role of CTA in penetrating and blunt trauma to the carotid and vertebral arteries is not well defined. We conducted a systematic literature review to determine the diagnostic accuracy of CTA for atherosclerotic, penetrating and blunt lesions in the carotid and vertebral arteries. METHODS: We searched MEDLINE and EMBASE databases to identify studies evaluating the diagnostic accuracy of CTA of the carotid and vertebral arteries published between January 1, 1992 and December 31, 2002. Two reviewers independently assessed abstracts and full text to determine study eligibility. Information on methodological quality, imaging technique and diagnostic accuracy was abstracted from all eligible studies by three independent reviewers. We pooled sensitivity and specificity data from diagnostic accuracy studies of high methodological quality. RESULTS: Forty-three articles met the inclusion criteria and were included in the review. Thirty studies examined atherosclerotic disease, two blunt trauma, two penetrating trauma and nine examined patients with other pathology. Pooled data from 15 higher quality studies demonstrated that CTA had a sensitivity of 95% (91-97% CI) for detecting severe (>70%) atherosclerotic stenosis of the carotid artery. The specificity of CTA for severe stenosis was also high 98% (96-99% CI). CTA remained a sensitive technique (95%; 93-97% CI) when the criterion for a positive result is relaxed to moderate or greater (>30%) stenosis. Two studies raised concerns about the use of CTA in the blunt trauma setting, suggesting that CTA may not be sensitive for detecting small intimal injuries, although both of these studies used older technologies for either obtaining or viewing images. Conversely, two penetrating trauma studies concluded that the sensitivity of CTA was high. CONCLUSIONS: Our findings demonstrate that CTA is both a sensitive and specific imaging technique for identifying severe atherosclerotic stenosis and occlusion of the carotid arteries. However, there is currently not enough high quality evidence to accurately estimate the sensitivity and specificity of CTA in the setting of blunt or penetrating trauma.

Angiography↗

Insufficient diagnostic accuracy of imported serological kits for Helicobacter pylori infection in Japanese population.

Although there are many reports of the high diagnostic accuracy of commercially available serologic kits for Helicobacter pylori infection in Western countries, they rarely has been investigated in oriental population. Accordingly we examined their usefulness in 492 Japanese patients with dyspeptic symptoms. Diagnostic accuracy of 4 imported serologic kits (HEL-p TEST, HM CAP, G.A.P IgG, Helico G2) was investigated using the (13)C-urea breath test as the gold standard. When intermediate results were excluded, the sensitivity, specificity and accuracy of these serologic tests ranged from 88.6% to 97.8%, 67.9% to 85.9%, and 87.9% to 91.4%, respectively, which were comparable with reported median accuracy in the Western population. However, there were many intermediate results in these tests, ranging from 5.3% to 23.0%. Their usefulness seemed to be limited in our patient population because of the large number of intermediate results.

Adult↗

Accuracy of computerized electrocardiographic identification of left ventricular hypertrophy as determined by echocardiographic measurements of left ventricular mass: evaluation of a widely used computer program.

The Hewlett-Packard 1000 electrocardiographic management system employs a user-interactive computer with revisable software. The diagnostic accuracy of this system in predicting left ventricular hypertrophy has been evaluated by comparing computer-predicted with anatomic left ventricular hypertrophy. The latter was defined as a left ventricular mass greater than 247 g as determined by M-mode echocardiography within 1 week of the computerized electrocardiogram. In this study, the Hewlett-Packard system was evaluated in 134 consecutive patients having anatomic left ventricular hypertrophy and 157 similarly studied patients with a normal left ventricular mass. By means of various combinations of voltage criteria, ST-T wave changes, abnormal QRS duration or ventricular activation time, left atrial enlargement and left axis deviation, the computer correctly identified 43 of 134 patients with left ventricular hypertrophy (sensitivity 32%); left ventricular hypertrophy was suggested or identified in an additional 18 patients with a normal left ventricular mass (specificity 89%). Graded probability statements (that is, the "strength" of the left ventricular hypertrophy diagnosis) increased with ventricular mass not only in patients with anatomic left ventricular hypertrophy but also in the patients with a "false positive" computerized electrocardiogram. Overall diagnostic accuracy was improved only in men by adjusting the definition of left ventricular hypertrophy for sex (at least 300 g for men and 220 g for women). Diagnostic accuracy was significantly better in patients 65 years of age and younger than in older patients (p = 0.007). It is concluded that the overall performance of this computer program (version ECLSB6) requires modification to improve its accuracy in identifying left ventricular hypertrophy.

Age Factors↗

Dobutamine-atropine stress echocardiography for reversible dysfunction during the first week after acute myocardial infarction: limitations and determinants of accuracy.

OBJECTIVES: We sought to compare the accuracy of biphasic and ischemic responses and sustained improvement for reversible dysfunction and to identify causes of false negative and false positive findings. BACKGROUND: Previous studies have shown that low dose dobutamine echocardiography was accurate for detecting reversible dysfunction after acute myocardial infarction (MI) but did not determine whether accuracy was improved by peak dose findings or influenced by the test interval or clinical or angiographic factors. METHODS: Dobutamine-atropine stress echocardiography (DASE) (baseline, low dose [5 and 10 microg/kg body weight per min] and peak dose) and coronary angiography were performed in 115 patients 2 to 7 days after MI (test interval). Segmental wall thickening was analyzed according to the 16-segment model. Sustained improvement and biphasic and ischemic responses included improved wall thickening at low and peak doses, improved wall thickening at the low dose with worsening at peak dose and no change in wall thickening at the low dose with worsening at peak dose, respectively. Follow-up echocardiography was performed at 4 to 8 weeks, and reversible dysfunction was defined as improved wall thickening. RESULTS: Wall thickening improved at follow-up in 305 (44%) of 688 dysfunctional segments. The test interval was 2 days in 16 patients, 3 days in 24, 4 days in 24, 5 days in 12, 6 days in 16 and 7 days in 23. No change at low and peak doses accurately predicted fixed dysfunction (318 [88%] of 360 segments), especially in akinetic and dyskinetic segments (276 [91%] of 303), irrespective of the test interval or clinical and angiographic factors. Ischemic segmental responses also predicted fixed dysfunction (63% [12 of 19 patients]), especially in medically treated compared with revascularized patients (100% [8 of 8] vs. 36% [4 of 11], p = 0.013). Both biphasic responses and sustained improvement (77% [179 of 231 segments] vs. 87% [84 of 97], p = 0.082) were highly predictive of reversible dysfunction, especially in akinetic segments, irrespective of the test interval or clinical and angiographic factors. The only limitation was reduced accuracy (77% [177 of 222 segments], p < 0.001) due to false positive results (16%) in hypokinetic segments. CONCLUSIONS: No change and ischemic responses during DASE were specific for fixed dysfunction. Improved wall thickening at the low dose, irrespective of changes at peak dose, was highly predictive of reversible dysfunction. Accuracy was only limited by false positive results in hypokinetic segments and not by the test interval or clinical or angiographic factors.

Atropine↗

Functional anatomy of mitral regurgitation: accuracy and outcome implications of transesophageal echocardiography.

OBJECTIVES: This study was performed to determine the accuracy and outcome implications of mitral regurgitant lesions assessed by echocardiography. BACKGROUND: In patients with mitral regurgitation (MR), valve repair is a major incentive to early surgery and is decided on the basis of the anatomic mitral lesions. These lesions can be observed easily with transesophageal echocardiography (TEE), but the accuracy and implications for outcome and clinical decision-making of these observations are unknown. METHODS: In 248 consecutive patients operated on for MR, the anatomic lesions diagnosed with TEE were compared with those observed by the surgeon and those seen on 216 transthoracic echocardiographic (TTE) studies, and their relationship to postoperative outcome was determined. RESULTS: Compared with surgical diagnosis, the accuracy of TEE was high: 99% for cause and mechanism, presence of vegetations and prolapsed or flail segment, and 88% for ruptured chordae. Diagnostic accuracy was higher for TEE than TTE for all end points (p < 0.001), but the difference was of low magnitude (<10%) except for mediocre TTE imaging or flail leaflets (both p < 0.001). The type of mitral lesions identified by TEE (floppy valve, restricted motion, functional lesion) were determinants of valve repairability and postoperative outcome (operative mortality and long-term survival; all p < 0.001) independent of age, gender, ejection fraction and presence of coronary artery disease. CONCLUSIONS: Transesophageal echocardiography provides a highly accurate anatomic assessment of all types of MR lesions and has incremental diagnostic value if TTE is inconclusive. The functional anatomy of MR defined by TEE is strongly and independently predictive of valve repairability and postoperative outcome. Therefore, the mitral lesions assessed by echocardiography represent essential information for clinical decision making, particularly for the indication of early surgery for MR.

Aged↗

Determination of accuracy of preoperative templating of noncemented femoral prostheses.

The purpose of this study was to determine the accuracy of preoperative templating of primary, noncemented femoral components. A retrospective review of charts and radiographs was performed on 74 hips in 64 patients who had undergone either noncemented total hip arthroplasty (THA) or placement of an endoprosthesis (including bipolar). Preoperative radiographs were templated by a total joint arthroplasty attending surgeon, a senior orthopaedic resident, and a junior resident. The templated size corresponded to the actual femoral implant used in approximately 50% of cases. When femoral prostheses within one size above or below the templated size were included, the accuracy of preoperative templating rose to 88-95%. When implants within two sizes of the templated size were included, the accuracy approached 100%. Factors associated with discrepancies in the size of femoral stem used included placement of an undersized implant, presence of metal hardware that obscured the ability to template accurately, proximal bone deformity, sclerotic bone, acute femoral neck fracture, and inadequate preoperative radiographs. The accuracy of templating increased gradually with the level of training. The most experienced investigator was able to template within one size of the actual implant used in 95% of cases, compared with 88% and 82% for the less experienced investigators. Acute femoral neck fractures and proximal bone deformity were associated with the largest discrepancies in templated sizes.

Adult↗

Accuracy of the Jamar dynamometer.

The purpose of the study was to check the calibrations of six Jamar dynamometers. Five handle positions were tested for each instrument, with the application of seven different external forces, from 5 kg to 60 kg. Between two testers the repeatability was also evaluated. Major differences in testing accuracies were not found according to different breadths of grip. The repeatability of testing accuracy among the two examiners was rather good, varying in average from only 1.2 kg to 1.4 kg per handle position. The error of absolute kilograms increased relating to heavier loads, but the percentage error decreased when the load increased. The accuracy of the older dynamometers was poorer than the accuracy of the newer ones. The normative values of hand grip related to different handle positions are reviewed.

Calibration↗

The Canadian experience in performing accuracy checks on administered doses of radiopharmaceuticals.

A calibration service was introduced in 1986 to assist the Canadian nuclear medicine community in determining more accurately the amount of radioactive material administered to patients for either diagnostic or therapeutic purposes. This aspect of a quality assurance program in nuclear medicine provides an accuracy check on instruments and the technologists using them. The calibration report issued constitutes direct traceability of a facility to a national standards laboratory. Nuclides most frequently calibrated are 99mTc and 131I. Others include 67Ga, 111In, 123I, 125I and 201Tl. All samples received are analysed for radionuclidic impurities by high-resolution X-ray and gamma-ray spectrometry. Ten years of testing has shown that, except for a few conscientious departments, accuracy checks on radionuclide (dose) calibrators are not a high priority. There are 285 nuclear medicine facilities in Canada and, since there is no legal requirement that the calibrators be checked for accuracy, only 29 have had their instruments checked using this service. Of these, 14 perform annual accuracy checks with NRCC. In this paper, the results of the intercomparisons are described, and quality control problems associated with the use of radionuclide calibrators in nuclear medicine are discussed.

Canada↗

Racial differences in accuracy of self-assessment of sexual maturation among young black and white girls.

PURPOSE: To examine the validity of maturation self-assessments and to investigate the association between race and validity of self-assessments among young black and white girls. METHODS: Self-assessments and examiner-assessments of areolar and pubic hair development using line drawings were compared at three visits among a cohort of 11- to 14-year-old girls enrolled in the National Heart, Lung, and Blood Institute's Growth and Health Study. Accuracy rates and kappa coefficients were calculated to measure the agreement between girls and examiners. Logistic regression models were used to assess the racial differences in the accuracy of self-assessments while adjusting for possible confounders. RESULTS: Fair to moderate agreement was found between self- and examiner-assessments (areolar self-assessments: adjusted accuracy rates: 60.7-69.9%, kappa: 0.32-0.51; pubic hair self-assessments: adjusted accuracy rates: 57.9-70.7%, kappa: 0.36-0.55). While there were indications of racial differences in the ability to perform self-assessment with black girls tending to self-assess less accurately, most of the differences disappeared after adjusting for nurse-assessed stage. CONCLUSIONS: These findings suggest that self-assessment can substitute for examiner evaluations only when crude estimates of maturation are needed. However, when accurate maturation stage data are required, examiner-assessments are necessary. Because black girls are usually more pubertally advanced and tend to underestimate their development, the value of self-assessment is questionable for assessing populations with young black and white girls. Use of self-assessment might present biased estimates of maturation and confound research findings.

Adolescent↗

Diagnostic accuracy of dipyridamole technetium 99m-labeled sestamibi myocardial tomography for detection of coronary artery disease.

BACKGROUND: The diagnostic accuracy of exercise 99mTc-labeled sestamibi and intravenous dipyridamole 201Tl-labeled myocardial tomography is established. The accuracy of dipyridamole stress 99mTc-labeled sestamibi myocardial tomography for the detection of coronary artery disease has not been reported. METHODS AND RESULTS: Our purpose was to determine the diagnostic accuracy of same-day, rest-dipyridamole stress 99mTc-labeled sestamibi myocardial single-photon emission computed tomography (SPECT) compared with coronary angiography. Two hundred forty-four patients who were unable to exercise adequately underwent both dipyridamole 99mTc-labeled sestamibi SPECT and coronary angiography within 6 months. Dipyridamole was administered intravenously in a standard dose of 0.56 mg/kg for 4 minutes. Cardiac and noncardiac side effects were recorded. The presence of coronary stenoses of 50% or greater diameter reduction in each of the major coronary arteries was compared with imaging data in corresponding myocardial perfusion beds. The patient population was predominately (98.8%) male with a mean age of 63 +/- 9 years (range 33 to 83 years). The majority of patients had stable angina (88%). Eighty-four patients (35%) gave a prior history of myocardial infarction; 44 patients (18%) had a history of congestire heart failure. The principal limitation to exercise stress was peripheral vascular disease in 62 patients (26%). No serious side effects occurred during dipyridamole stress; 14% of patients had chest pain and 8% of patients had 1 mm or greater ST segment depression. Of the 204 patients with documented coronary stenoses, 43 (21%) had single-vessel disease and 161 (79%) had multivessel disease. The sensitivity was 93% (40/43 in patients with single-vessel disease) and 91% (146/161 in patients with multivessel disease). Overall sensitivity was 91%. The specificity was 28% (11/40) in this population with a high prestest probability of coronary artery disease and posttest referral for cardiac catheterization. CONCLUSION: 99mTc-labeled sestamibi myocardial tomography in conjunction with intravenous dipyridamole stress is a safe and sensitive method for the detection of coronary artery disease. The diagnostic accuracy of dipyridamole stress 99mTc-labeled sestamibi SPECT for the detection of coronary artery disease is similar to that reported for exercise stress 99mTc-labeled sestamibi tomography, making this a suitable alternative for the evaluation of patients who are unable to exercise adequately.

Adult↗

Effects of morphine analgesia on diagnostic accuracy in Emergency Department patients with abdominal pain: a prospective, randomized trial.

BACKGROUND: Because of concerns about masking important physical findings, there is controversy surrounding whether it is safe to provide analgesia to patients with undifferentiated abdominal pain. The purpose of this study was to address the effects of analgesia on the physical examination and diagnostic accuracy for patients with abdominal pain. STUDY DESIGN: The study was a prospective, double-blind clinical trial in which adult Emergency Department (ED) patients with undifferentiated abdominal pain were randomized to receive placebo (control group, n = 36) or morphine sulphate (MS group, n = 38). Diagnostic and physical examination assessments were recorded before and after a 60-minute period during which study medication was titrated. Diagnostic accuracy and physical examination changes were compared between groups using univariate statistical analyses. RESULTS: There were no differences between control and MS groups with respect to changes in physical or diagnostic accuracy. The overall likelihood of change in severity of tenderness was similar in MS (37.7%) as compared with control (35.3%) patients (risk ratio [RR] 1.07, 95% confidence interval [CI] 0.64-1.78). MS patients were no more likely than controls to have a change in pain location (34.0% versus 41.2%, RR 0.82, 95% CI 0.50-1.36). Diagnostic accuracy did not differ between MS and control groups (64.2% versus 66.7%, RR 0.96, 95% CI 0.73-1.27). There were no differences between groups with respect to likelihood of any change occurring in the diagnostic list (37.7% versus 31.4%, RR 1.20, 95% CI 0.71-2.05). Correlation with clinical course and final diagnosis revealed no instance of masking of physical examination findings. CONCLUSIONS: Results of this study support a practice of early provision of analgesia to patients with undifferentiated abdominal pain.

Abdominal Pain↗

Accuracy of preoperative localization studies and intraoperative parathyroid hormone assay in patients with primary hyperparathyroidism and double adenoma.

BACKGROUND: The purpose of this retrospective investigation was to evaluate the results of preoperative localization studies and intraoperative parathyroid hormone (IOPTH) assay in patients with primary hyperparathyroidism and double adenomas. STUDY DESIGN: Twenty-one of 287 consecutive patients with primary hyperparathyroidism who had double adenomas identified during first-time parathyroid exploration between July 1999 and September 2002 were analyzed. Individual and combined accuracy of preoperative localization studies, and IOPTH assay and their influence on surgical strategy, were compared. RESULTS: Seven percent of these 287 patients had double adenomas. Fifteen of the patients were female and six were male with a mean age of 59 years (range 17 to 76 years). The accuracy of ultrasonography (US) and technetium 99m sestamibi ((99m)TC-sestamibi) was 40% and 30%, respectively, in this select group. Combined accuracy of both tests reached 60% and guided the surgeon to select a bilateral approach. After removal of the first gland, IOPTH failed to decrease by 50% relative to the highest baseline value in 43% of the cases, indicating other hyperfunctioning parathyroid glands. These results prompted the surgeon to explore further after an initially planned focused approach. When the combination of three tests was analyzed, at least one test accurately suggested a double adenoma in 80% of the patients; in 15% of the patients, no test was suggestive of a double adenoma and in 5% the sestamibi scan was false positive. CONCLUSIONS: This retrospective investigation documents that neither preoperative localization tests nor IOPTH assay accurately document double adenomas in patients with primary hyperparathyroidism. The combined accuracy of US, sestamibi, and IOPTH assay predicted a double adenoma in 80% of the patients.

Adenoma↗

The accuracy of sentinel lymph node biopsy in multicentric and multifocal invasive breast cancers.

BACKGROUND: Sentinel lymph node biopsy (SLNB) has proved to be an accurate alternative to complete axillary lymph node dissection (ALND) in clinically node-negative breast cancer patients. Multicentric (MC) and multifocal (MF) invasive breast cancers are considered to be relative contraindications to SLNB. We examine the accuracy of SLNB in patients with MC and MF invasive breast cancers. STUDY DESIGN: From September 1996 to August 2001, a total of 3,501 patients with clinically node-negative breast cancer underwent SLNB using both blue dye and radioisotope at our institution. A total of 70 patients had MC or MF invasive breast cancer, a successful SLNB, and mastectomy for local control. All had >/=10 axillary nodes excised (including the SLN) in a planned ALND. Exclusion criteria included MC and MF in situ carcinoma; breast conservation; previous breast irradiation, ALND, or SLNB; recurrent breast cancer; neoadjuvant chemotherapy; or ALND based solely on SLNB pathologic examination. RESULTS; The incidence of axillary metastases was 54% (38 of 70). SLNB accuracy was 96% (67 of 70), sensitivity 92% (35 of 38), and false-negative rate 8% (3 of 38). All patients with an inaccurate SLNB had a dominant invasive tumor >5 cm and one patient had palpable axillary disease intraoperatively. The SLN was the only site of axillary metastasis in 37% (14 of 38). Results were compared with those of published SLNB validation studies, most of which reflect experience with single-site invasive breast cancers. No statistically significant difference was noted for accuracy, sensitivity, or false-negative rate. CONCLUSIONS: SLNB accuracy in MC and MF disease is comparable with that of published validation studies. MC and MF patients with a dominant T3 tumor (>5 cm) or axillary disease palpable intraoperatively should have a concurrent formal ALND. Our retrospective data suggest SLNB may be used as a reliable alternative to conventional ALND in selected patients with MC or MF disease. Further studies in this patient population are warranted.

Adult↗

Accuracy of hysteroscopy in predicting histopathology of endometrium in 1500 women.

STUDY OBJECTIVE: To estimate the accuracy of hysteroscopy in predicting endometrial histopathology. DESIGN: Retrospective analysis (Canadian Task Force classification II-2). SETTING: Public hospital. PATIENTS: One thousand five hundred women undergoing diagnostic hysteroscopy for suspected endometrial pathology, mostly because of abnormal uterine bleeding. INTERVENTIONS: Hysteroscopy and endometrial biopsy. MEASUREMENTS AND MAIN RESULTS: Hysteroscopy imaging was matched with histology. Functional, dysfunctional, and atrophic endometrium were considered normal findings; endometritis, endometrial polyps, hyperplasia, and carcinomas were considered abnormal. Sensitivity, specificity, and negative (NPV) and positive (PPV) predictive values of hysteroscopy in detecting normal or abnormal endometrium were calculated. These figures were defined to assess hysteroscopic accuracy in estimating pathologic conditions. Histology showed normal endometrium in 927 patients. Endometritis, polyps, hyperplasia, and malignancies were found in 21, 265, 185, and 102 patients, respectively. Hysteroscopy showed sensitivity, specificity, NPV, and PPV of 94.2%, 88.8%, 96.3%, and 83.1%, respectively, in predicting normal or abnormal histopathology of endometrium. Highest accuracy was in diagnosing endometrial polyps, with sensitivity, specificity, NPV, and PPV of 95.3%, 95.4%, 98.9%, and 81.7%, respectively; the worst result was in estimating hyperplasia, with respective figures of 70%, 91.6%, 94.3%, and 60.6%. All failures of hysteroscopic assessment resulted from poor visualization of the uterine cavity or from underestimation or overestimation of irregularly shaped endometrium. CONCLUSION: Hysteroscopy was accurate in distinguishing between normal and abnormal endometrium. Nevertheless, better knowledge of relationship between hysteroscopic imaging and pathophysiologic states of endometrium is necessary to improve its accuracy. Endometrial sampling is recommended in all hysteroscopies showing unevenly shaped and thick endometrial mucosa or an anatomically distorted uterine cavity, and when endouterine visualization is less than optimal.

Adult↗

Accuracy of MR imaging for staging prostate cancer: a meta-analysis to examine the effect of technologic change.

RATIONALE AND OBJECTIVES: The purpose of this study was to summarize the accuracy of magnetic resonance (MR) imaging for staging prostate cancer and to determine the effect of high magnetic field strength, use of the endorectal coil, use of fast spin-echo (SE) imaging, and study size on staging accuracy. MATERIALS AND METHODS: A literature search and review yielded 27 studies comparing MR imaging to a pathologic standard in patients with clinically limited prostate cancer. Subgroup analyses examined magnetic field strength, use of an endorectal coil, use of fast SE imaging, publication date, and study size. RESULTS: A summary receiver operating characteristic curve for all studies had a maximum joint sensitivity and specificity of 74%. At a specificity of 80% on this curve, sensitivity was 69%. Subgroup analyses showed that fast SE imaging was statistically significantly more accurate than conventional SE techniques (P < .001). Unexpectedly, studies employing higher magnetic field strength and those employing an endorectal coil were less accurate. CONCLUSION: Seemingly small technologic advances may influence test accuracy. Early and small studies, however, may overstate accuracy because of publication bias, bias in small samples, or earlier studies being performed by the experts who developed the technology itself.

Humans↗

Accuracy of skin prick tests in IgE-mediated adverse reactions to bovine proteins.

OBJECTIVES: To review the recent literature on the diagnostic accuracy of skin prick tests (SPTs) in pediatric food allergy, focusing on adverse reactions to milk and beef. To present data about the test performance characteristics of beef extracts used in SPTs among children with atopic dermatitis (AD) reporting immediate hypersensitivity to beef. DATA SOURCES: MEDLINE search using the following algorithm ["skin prick test" AND "food allergy" OR allergen; 1997-2002; English; all children]. Prospective sensitivity study of SPTs in 34 patients. STUDY SELECTION: Thirty-four children with AD (median age 2.29 years) were consecutively recruited between 1992 and 2000 because of immediate reactions to beef. On double-blind, placebo-controlled food challenges (entry criterion), 20 of the patients reacted to beef and 14 did not. Cut-off points for skin prick test wheal positivity was selected by receiving-operator characteristic analysis for fresh and commercial beef allergens. Sensitivity and specificity of skin tests and indices of reproducibility were calculated. RESULTS: In the literature, the positive predictive accuracies of skin prick tests vary between 69 and 100% and the negative predictive accuracies between 20 to 86% for cow's milk. In our series, SPTs with commercial beef extracts were highly diagnostic (100% sensitivity; 10% false positive rate) and SPTs with fresh beef were highly specific (100%), albeit with a false-positive rate of 21.42%. CONCLUSIONS: From the literature, we conclude that the diagnostic accuracy of SPTs with milk should be reappraised in the workup of cow's milk allergy. Carrying out commercial and fresh food SPTs at the same time substantially reduces costs and diagnostic work. Oral provocation is necessary in 20.68% of children with AD who have immediate symptoms to beef. Greater allergen standardization and streamlining of the workup of cow's milk allergy are desirable future goals.

Allergens↗

Portable infusion pumps used for continuous regional analgesia: delivery rate accuracy and consistency.

BACKGROUND AND OBJECTIVES: Multiple benefits of postoperative perineural local anesthetic infusion have been shown including potent analgesia, decreased opioid requirements, and improved rehabilitation. Consequently, portable infusion pumps have been used with increasing frequency to provide perineural infusion for medically unsupervised ambulatory patients. We believe that the infusion rate accuracy and reliability of these pumps infusing potentially toxic doses of medication should be investigated independently. Therefore, we studied the flow-rate accuracy and consistency of various portable infusion pumps that have not been examined previously. METHODS: Using a computer/mass balance combination to record infusion rates, 6 pumps (3 electronic and 3 non electronic) were tested. Several factors that may influence pump performance were varied: temperature (ambient/skin), battery (replacement/addition), and catheter exchange (wound/perineural). RESULTS: Infusion rate accuracy differed significantly among the pumps, exhibiting flow rates within +/-15% of their expected rate for 55% to 99% of their infusion duration. Furthermore, the profiles (infusion rate over time) of the various pumps differed significantly depending on the pump power source. Although elastomeric pump infusion rate increased with an increase in temperature, battery life was a limiting factor for one of the electronic pumps. Substituting wound catheters with commonly used perineural catheters did not significantly alter infusion profile. CONCLUSIONS: Factors such as infusion rate accuracy and consistency, infusion profile, temperature sensitivity, and battery life affect the dose of medication administered by various portable pumps used for continuous regional analgesia. Health care providers should take these factors into consideration when choosing and using a portable infusion pump for local anesthetic administration.

Analgesia↗