Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLATES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49Linked to original sources

Morphology and metabolism of hepatocytes microencapsulated with acrylic terpolymer-alginate using gelatin and poly(vinyl alcohol) as extracellular matrices.

Microcapsules with good mechanical stability were prepared using an appropriate mixture of alginate and acrylic terpolymer. It was found from the microscopic observation that the microcapsules had a porous structure with interconnected pores, with a size of 50-150 nm. The results of the permeability experiment of microcapsules using FITC-dextrans showed that the capsule had a molecular mass cut-off of 120 kDa. The hepatocytes encapsulated in both alginate and acrylic terpolymer with gelatin and PVA rapidly aggregated in the core. The aggregated cells showed high albumin synthesis and ammonia removal, suggesting good metabolic function.

Acrylates↗

Effect of poly (2-methoxyethyl acrylate)-coated oxygenators on haemolysis.

Blood contact with artificial device surfaces and mechanical trauma are two major factors for haemolysis. Poly(2-methoxyethyl acrylate) (PMEA) is an amphiphilic polymer with a polyethylene chain that is hydrophobic and a mildly hydrophilic tail. PMEA coating has showed positive effects on protein adsorption, platelet loss, platelet aggregation and post-operative bleeding in previous studies. In this study, effects of poly(2-metoxyethyl acrylate) (PMEA)-coated oxygenators on haemolysis was investigated. PMEA-coated (SX18-Capiox) oxygenators were used. Desorbed erythrocyte, free haemoglobin indirect bilirubin and total bilirubin quantities from fibre samples of oxygenators were studied. Erythrocyte, total bilirubin and direct bilirubin values were measured from blood aliquots taken in five different times during cardiopulmonary by-pass (CPB); baseline (T1), during CPB (T2), at the end of CPB (T3), after protamine injection (T4) and in intensive care (T5). In both coated and non-coated oxygenators haemolysis rate was in clinically acceptable safety range. Average desorbed free haemoglobin was 6663 mg/dl from coated and 29.405 mg/dl from non-coated fibres. Average desorbed total bilirubin was 0.0068 mg/dl from coated and 0.023 mg/dl from noncoated fibres. We observed less haemolysis, as reflected by lower desorbed free haemoglobin and indirect bilirubin from coated oxygenators and less decrease in blood erythrocyte number. Blood bilirubin concentration was low in the coated group when compared to the control group. This study describes the relationship between PMEA coating and haemolysis at the blood contacting surface. PMEA coating reduces red blood cell damage during extracorporeal circulation.

Acrylates↗

Molecular calculations of poly(ethylene glycol) transport across a swollen poly(acrylic acid)/mucin interface.

The transport of poly(ethylene glycol) chains than can promote mucoadhesion across the interface between lightly cross-linked poly(acrylic acid) and mucin may be analyzed as a function of molecular characteristics using theories of chain penetration in a dilute network. The fracture energy for the ensuing adhesive bond is proportional to the number of polymer chains crossing the interface, which, in turn, is related to the polymer volume fraction, the chain diffusion coefficient, and the degree of polymerization. Relevant calculations were performed for a number of cross-linked poly(acrylic acid) gels and three different types of poly(ethylene glycol) chains.

Acrylic Resins↗

Frictional behavior and surface failure of acrylic denture teeth.

The water characteristics of acrylic denture teeth were investigated under single- and double-pass sliding. The response of acrylic teeth to sliding was that of a relatively ductile material. The wear characteristics were affected similarly by environments of water and saliva. The "enamel" surfaces showed more resistance to penetration and were less susceptible to surface damage than the "dentin" surfaces. The effect of the second pass was to increase track width and cause a more severe mode of surface failure.

Acrylic Resins↗

Sustainability of forestomach hyperplasia in rats treated with ethyl acrylate for 13 weeks and regression after cessation of dosing.

In a chronic study conducted by the National Toxicology Program (NTP), gavage administration of 100 or 200 mg ethyl acrylate (EA)/kg/day, 5 days/week, to F344 rats and B6C3F1 mice resulted in a significant dose-dependent increase in the incidence of squamous cell papillomas and carcinomas of the forestomach of both sexes of rats and mice. No increase in the incidence of tumors was observed at any other site in these rats. Chemically-induced cell proliferation is currently thought to play a role in the development and progression of chemically-induced neoplasia. Therefore, a stop-study was initiated where 100 or 200 mg EA/kg (in corn oil) was administered daily, 5 days/week, for 13 weeks. Rats sacrificed at the end of the treatment regimen had severe epithelial hyperplasia of the forestomach. No lesions were observed in the glandular stomach or liver of EA-treated rats. Forestomach hyperplasia induced by EA included upward and downward cell proliferation. However, forestomachs of rats treated for 13 weeks and sacrificed 8 weeks after the last EA dose exhibited a significant decline in the incidence and severity of forestomach mucosal hyperplasia. Histopathologic evaluation of forestomachs of EA-treated rats (13 weeks) which were allowed a 19-month-recovery (with no exposure to EA) showed further decline in the incidence and severity of mucosal cell hyperplasia. These results indicate that gavage administration of EA to rats results in extensive and sustained forestomach mucosal hyperplasia. The sustainability of forestomach hyperplasia is apparently dependent on the continued exposure of rats to ethyl acrylate, and regressed after cessation of dosing. Furthermore, although enough post-treatment time was allowed for tumors to develop after cessation of EA administration, forestomachs exhibited a nearly complete recovery with no increased incidence of papillomas or carcinomas. It, therefore, remains to be determined what duration of exposure or other factors are critical for reversibility or progression of EA-induced forestomach mucosal hyperplasia to neoplasia.

Acrylates↗

The effect of modification of acrylic resins on controlled release and bioadhesion.

The effect of various treatments on the properties of an acrylic matrix was studied, in terms of its swelling properties in buffer solution. The release of two types of drugs from those matrices and their bioadhesive character were also considered. Calcium stearate and sodium lauryl sulfate were used as additives for the matrix treatment. 2-Hydroxyethyl methacrylate was also used as a reactive agent for the acrylic resin treatment. The main function of the above chemicals is the modification of the hydrophilic/hydrophobic character of the matrix. This investigation showed that controlled release systems can be designed by adjusting the matrix properties via additives or chemical reaction.

Acrylic Resins↗

The creep behavior of acrylic denture base resins.

The creep behavior of acrylic dental base resins, at room temperature and at different loading conditions, has been examined. The behaviors of these resins are similar to that of "commercial perspex" at room temperature over a period of 1000 seconds. The pseudo-elastic moduli of the blends of PMMA VC show a significant increase compared with PMMA alone. The addition of the PVC powder to the heat-cured acrylic resin increased the time-dependent elastic modulus. This increase in elastic modulus is advantageous in the production of denture based resins of improv mechanical properties.

Acrylic Resins↗

Pluronic block copolymers and Pluronic poly(acrylic acid) microgels in oral delivery of megestrol acetate.

Several Pluronic-based formulations were studied in-vitro and in a rat model with respect to the release and bioavailability of megestrol acetate (MA) after oral administration. It was demonstrated that an aqueous, micellar formulation comprising a mixture of a hydrophobic (L61) and a hydrophilic (F127) Pluronic copolymer, significantly enhanced the bioavailability of MA administered orally at relatively low doses (1-7 mg kg(-1)). Pluronic-based microgels (spherical gel particles of sub-millimetre size) were introduced as MA vehicles. The microgels comprised a cross-linked network of poly(acrylic acid) onto which the Pluronic chains were covalently attached. Microgels of Pluronic L92 and poly(acrylic acid) fabricated into tablet dosage forms exhibited dramatically lowered MA initial burst release. The MA release was pH-dependent owing to the pH sensitivity of the microgel swelling, with the drug retained by the microgel at pH 1.8 and released slowly at pH 6.8. In the rat model, a significant increase in MA bioavailability was observed when the microgel-formulated MA was administered orally at a high dose of 10 mg kg(-1), owing to the enhanced retention of the microgel. The study of the microgel passage through the gastrointestinal tract demonstrated the microgel retention characteristic of a very high molecular weight polymer and the absence of any systemic absorption of the polymer.

Acrylates↗

Use of acrylic in anterior cervical discectomy: technical note.

Acrylic was inserted into the intervertebral space after anterior cervical discectomy in five patients. The application of the acrylic was simple and quick to perform and atraumatic to the patient. The intervertebral space was preserved satisfactorily and consistently in all five patients. With this technique, the complications associated with bone grafts can be avoided.

Acrylic Resins↗

Gentamicin sulphate release from a modified commercial acrylic surgical radiopaque bone cement. I. Influence of the gentamicin concentration on the release process mechanism.

The purpose of the present work was the study of the gentamicin sulphate (GS) release from a commercial acrylic bone cement CMW-1 with the aims of establishing the influence of the slabs preparation as well as the release mechanism and kinetics. The effect of the amount of GS on the release kinetic parameters has been also investigated. In vitro release studies were performed in a buffered saline solution at pH 7.4 and 37 degrees C. The GS concentration was determined using an indirect spectrophotometric method with an o-phthaldialdehyde as a derivatizing reagent. A commercial and three modified samples were tested. The free and fractured surfaces of the GS cement slabs before and after the release studies were observed by means of scanning electron microscopy (SEM). For low GS concentration loading the release was very incomplete because most of the GS beads were encapsulated by the hydrophobic PMMA matrix. A higher amount of antibiotic was released from cement that has a higher amount incorporated. A model and therefore a mechanism of release based on this model have been proposed. It has allowed us to explain the changes in dissolution kinetics of an acrylic matrix type controlled release system up to 12% GS loading. The cumulative amount of GS released M(t)/M(i), was fitted as a function of time. For lower amounts of GS, the regression analysis (R(2)>0.99) revealed that the release is most adequately represented by M(t)/M(i)=b+kt(n), where b represents a burst effect. The goodness of fit decreases as the amount of GS increases. The influence of some other type of release mechanism for higher amounts of GS must be taken into account and a second model for the release, M(t)/M(i)=b+k x [1-exp(-kt)], is proposed.

Acrylates↗

Characteristics of hyaluronate-hydroxyethyl acrylate blend gel and release of cationic amphiphilic solutes.

Hyaluronate-hydroxyethyl acrylate blend gel (HA-PHEA) were prepared to modify the brittleness of hyaluronate gel (HA) and the characteristics of HA-PHEA gel were compared with those of HA and polyhydroxyethyl acrylate (PHEA) gels. These gels were high in water content and transparent. HA-PHEA gel was improved in viscoelastic properties due to the elasticity and the high affinity with water of PHEA, and the drying-swelling cycles became reversible. The effective charge densities theta of the gels estimated from membrane potentials were -0.002, -0.008 and 0 mol dm(-3) for HA-PHEA, HA and PHEA gels. Effects of electro- static and nonelectrostatic interactions on absorptions and releases were studied using sodium benzoate (NaBA) as an anionic solute, and methylene blue (MB), chlorpromazine (CPHCl) and benzethonium chloride (BZTCl) as cationic solutes, in which CPHCl and BZTCl are cationic amphiphilic solutes. The releases of MB, CPHCl and BZTCl from HA-PHEA and HA gels were suppressed comparing with those of NaBA. By adding salts, the releases of MB and CPHCl were enhanced but those of BZTCl were suppressed due to enhancement of the intra- and intermicelle formation. In the releases of the cationic solutes from HA-PHEA gel, electrostatic and nonelectrostatic interactions with HA were found to play important roles. Behaviors of the releases from HA-PHEA gel were found to possess the features of HA gel.

Acrylates↗

Antibiotic-loaded acrylic cement.

Laboratory experiments and clinical investigations have confirmed the various claims made originally by Buchholz and Engelbrecht (1970) that antibiotic-loaded acrylic cement releases the antibiotic into the surroundings in useful concentrations. Palacos R cement released higher concentrations than CMW, Simplex and Sulfix brands of cement and over longer periods. Concentrations of gentamycin and fucidin were sufficient to penetrate dead cortical bone. These conclusions need to be assessed with animal studies, mechanical testing and clinical results before the ideal place of antibiotic-loaded acrylic cement is established.

Acrylic Resins↗

Reline materials--handle with care? An investigation into the effect of varying the powder/liquid ratio on some properties of auto-polymerising acrylic resin materials.

INTRODUCTION: The fit of the denture base to the alveolar ridge progressively declines with alveolar ridge resorption. Once a denture becomes ill-fitting there are two main treatment options: to construct a new denture or to restore the fit of the existing denture. A denture may be relined as a laboratory procedure or at the chairside in the dental clinic. The chairside reline technique involves the direct application of auto-polymerising acrylic resin materials to the prepared denture base and the material is allowed to polymerise in the patient's mouth. The reline materials are generally supplied as a powder and a liquid. Clinicians and laboratory dental staff do not always follow manufacturers' recommended guidelines and the tendency can be simply to add varying quantities of powder and liquid until the desired consistency is achieved. This method however may have deleterious effects on the properties of the resultant material. MATERIALS AND METHOD: The aim of the study was to investigate the effect of varying the powder/liquid ratio on some properties of three auto-polymerising acrylic resin reline materials. The properties investigated were the flow characteristics in terms of the manipulation and setting time and the hardness. Four powder and liquid ratios were chosen. RESULTS AND CONCLUSIONS: For all the materials studied, a clinically useful lengthening of the manipulation time can be achieved by increasing the amount of liquid added to the powder. However, this is perhaps offset by the fact that it is associated with a corresponding increase in the setting time and resultant increase in clinical chairside time. There were significant differences in surface hardness when the powder/liquid ratio was altered.

Acrylic Resins↗

Effect of cinnamic and acrylic acids' derivatives on luminol-enhanced chemiluminescence of neutrophils.

Fourteen derivatives of cinnamic and acrylic acids were evaluated for their ability to modulate chemiluminescence, evoked by neutrophils that had been exposed to luminol and phorbol-myristate-acetate. Compounds with one or two hydroxyl groups on the phenyl ring demonstrated significant inhibition of the chemiluminescence, but this inhibition was diminished by methoxylation. Saturation of the double bond in the aliphatic chain of cinnamic acid at C6-enhanced the chemiluminescence to a small degree. All three acrylic acid derivatives demonstrated a marked inhibition of the luminol chemiluminescence, indicating that characteristics of the heterocyclic ring is of utmost importance in this activity.

Acrylates↗

[Incidence of posterior capsule opacification in patients submitted to phacoemulsification and expandable acrylic intraocular lens implantation].

PURPOSE: To evaluate prospectively the results of expandable acrylic intraocular lenses in patients submitted to phacoemulsification as regard posterior capsule opacification. METHODS: The study group consisted of 830 patients, 1,200 eyes that underwent phacoemulsification from 1998 to 2002, by the same surgeon, using the same technique but with different diameters of capsulorrhexis, with expandable hydrophilic acrylic intraocular lens implantation. The mean follow-up was 2.4 years, ranging from 6 months to 4 years. RESULTS: The total number of posterior capsule opacification was 54 cases. CONCLUSIONS: The incidence of posterior capsule opacification was 4.6% in these patients.

Acrylic Resins↗

Influence of chemical and mechanical polishing on water sorption and solubility of denture base acrylic resins.

Influence of polishing methods on water sorption and solubility of denture base acrylic resins was studied. Eighty samples were divided into groups: Classico (CL), and QC 20 (QC) - hot water bath cured; Acron MC (AC), and Onda Cryl (ON) - microwave cured; and submitted to mechanical polishing (MP) - pumice slurry, chalk powder, soft brush and felt cone in a bench vise; or chemical polishing (CP) - heated monomer fluid in a chemical polisher. The first desiccation process was followed by storage in distilled water at 37 +/- 1 degrees C for 1 h, 1 day, 1, 2, 3 and 4 weeks. Concluding each period, water sorption was measured. After the fourth week, a second desiccation process was done to calculate solubility. Data were submitted to analysis of variance, followed by Tukey test (p<or=0.05). Means of water sorption (%) and solubility (%), respectively, were: CL-MP: 1.92 and 0.02; CL-CP: 1.98 and 0.52; QC-MP: 2.31 and -0.05; QC-CP: 2.32 and 0.25; AC-MP: 2.45 and -0.07; AC-CP: 2.43 and 0.41; ON-MP: 2.32 and -0.06; ON-CP: 2.34 and 0.27. Mechanical polishing promoted significantly lower solubility of acrylic resins; initially, water sorption values were higher for chemically polished samples, however, after 4 weeks all groups were similar.

Absorption↗