Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PLETHYSMOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48Linked to original sources

Validation of a continuous penile blood-flow measurement by pulse-volume-plethysmography.

Today, in the assessment of cavernous artery blood-flow, the most commonly used technique is Doppler ultrasound velocimetry (continuous, pulsed, color-coded or power), which is often considered as the gold standard. Plethysmographic techniques and radioactive tracers have been widely used for the assessment of global penis flow variations but are not adequate for continuous blood-flow measurement. A new pulse-volume plethysmographic (PVP) device using a water-filled penile cuff was employed to assess continuous blood-flow measurement in the penis. Simultaneously Doppler velocity was recorded and served as a gold standard. A penile water-cuff is connected through a pressure tube to a three-way tap. The pulse-volume changes in the penile water-cuff are measured by means of a latex membrane placed over one of the three-way taps. The displacements of the latex are recorded by a photoplethysmograph. The third tap is connected to a 5 l perfusion bag placed 30 cm above the penis so as to maintain constant pressure in the whole device whatever the penis volume. Twenty-four volunteers were tested. The Doppler velocity signal and pulse volume of cavernous arteries were measured simultaneously after PGE1 intra-cavernous injection. Blood-flow variations were induced by increasing penis artery compression with a second penile water-cuff used as a tourniquet fitted onto the penis root, and the pressure of which could be modified by a water-filled syringe. The amplitude of the plethysmographic pulse-volume signal and the area under the Doppler velocity signal were correlated. The inter-patient (n=24) correlation ranged from 0.455 to 0.904, with a mean correlation of 0.704 and P<0.0001. PVP measurement by a water-filled cuff was validated by ultrasound velocimetry. This new continuous, non-invasive and easy-to-use technique enables physiological and physiopathological flow-measurement during sleep, under visual sexual stimulation (VSS), or following artificial erection. Simultaneous recording of penile blood-flow by PVP and intra-cavernous pressure (ICP) measured by a non-invasive device will provide fundamental inflow and outflow information in both physiological and pathophysiological conditions, and further enable venous leakage to be assessed by a mathematical model.

Erectile Dysfunction↗

Role of the wrist cuff in forearm plethysmography.

1. To determine whether a wrist cuff is necessary to measure the forearm blood flow correctly, we studied the effects of wrist cuff inflation to supra-venous and supra-systolic pressure values over a large range of forearm blood flow values: in the basal state, during post-occlusive hyperaemia of the hand, and during heating of the hand with warm air. Eleven healthy men participated, and the study was carried out at two different ambient temperatures of 20 and 25 degrees C. 2. In the basal state, the measured forearm blood flow was lowest with the wrist cuff at supra-systolic pressure. With the wrist cuff at supra-venous pressure the forearm blood flow was also lower than with an uninflated cuff, but only significantly so when the basal forearm blood flow was higher (at a room temperature of 25 degrees C). 3. During post-occlusive hyperaemia, inflating the wrist cuff to supra-systolic pressure produced the lowest forearm blood flow value at both room temperatures. In addition, with the wrist cuff at supra-venous pressure, forearm blood flow values were lower than with the uninflated cuff, but the supra-venous cuff pressure was clearly less efficient in excluding the hand blood flow than the supra-systolic cuff pressure. 4. During heating of the hand, both supra-systolic and supra-venous cuff pressures were effective in excluding the hand blood flow at both room temperatures. The forearm blood flow measured with the wrist cuff at supra-systolic pressure was lower than that measured with the wrist cuff at supra-venous pressure, but the difference was only significant at a room temperature of 20 degrees C. 5. In conclusion, we have demonstrated that a wrist cuff at supra-systolic pressure is most appropriate for the exclusion of the hand circulation in order to measure the forearm blood flow correctly.

Forearm↗

Deep venous thrombosis: a prospective 3-month follow-up using duplex scanning and strain-gauge plethysmography.

1. The purpose of the study was to evaluate the degree of thrombus regression, development of valvular insufficiency, impaired calf muscle pump function and clinical symptoms after a period of acute deep venous thrombosis. 2. Seventy patients with acute deep venous thrombosis, diagnosed by duplex scanning or venography, received treatment with heparin and oral coumarin derivatives according to a standard protocol. All patients wore graduated compression stockings during the whole study period. Duplex scanning was performed at diagnosis and 1 and 3 months later to measure thrombus mass and reflux. The supine venous pump function test was used to assess calf muscle pump function. 3. Three months follow-up was completed in 60 patients. In total 218 (28%) out of 780 vein segments were initially thrombosed and 134 (17%) could not be traced. A statistically significant reduction of thrombus mass was recorded throughout the study period. Total resolution of thrombosis in all vein segments occurred in 25% of the patients within 1 month and in 40% in 3 months. There was no difference in regression between the various proximal vein segments. Distal segments showed more regression than proximal segments. Reflux occurred in 27% of the initially thrombosed veins and in 15% of the patent veins. Patients who showed total resolution after 1 month had a significantly higher calf muscle pump function than patients without total resolution (70%pf vs 61%pf, P < 0.05). Patients with reflux in two or more segments had a significantly lower calf muscle pump function than patients with reflux in less than two segments (58%pf vs 69%pf, P < 0.05). 4. Using duplex scanning and the supine venous pump function test 3 months after an acute deep venous thrombosis, overall haemodynamic abnormalities and local site of valve incompetence could readily be identified. Patients with haemodynamic abnormalities might be at risk to develop the post-thrombotic syndrome. There was no difference in thrombus regression between the various proximal vein segments. Reflux was significantly more often seen in initially thrombosed veins. Thirty-five percent of the patients developed an abnormal calf muscle pump function after 3 months. Patients with early resolution of thrombus had a higher calf muscle pump function after 3 months.

Adult↗

Computer assisted strain-gauge plethysmography is a practical method of excluding deep venous thrombosis.

AIM: To evaluate a computed strain-gauge plethysmograph (CSGP) as a screening tool to exclude above knee deep venous thrombosis (DVT). METHODS: The first phase took place in the Radiology department. One hundred and forty-nine patients had both Doppler ultrasound and CSGP performed. Discordant results were resolved by venography where possible. The second phase took place in an acute medical admissions ward using a modified protocol. A further 173 patients had both studies performed. The results were collated and analysed. RESULTS: Phase 1. The predictive value of a negative CSGP study was 98%. There were two false-negative CSGP results (false-negative rate 5%), including one equivocal CSGP study which had deep venous thrombosis on ultrasound examination. Two patients thought to have thrombus on ultrasound proved not to have acute thrombus on venography. Phase 2. The negative predictive value of CSGP using a modified protocol was 97%. There were two definite and one possible false-negative studies (false-negative rate 4-7%). CONCLUSION: Computer strain-gauge plethysmograph can provide a simple, cheap and effective method of excluding lower limb DVT. However, its use should be rigorously assessed in each hospital in which it is used. Goddard, A. J. P., Chakraverty, S. & Wright, J. (2001). Clinical Radiology56, 30-34.

Acute Disease↗

[Stability of lung function parameters: spirometry, body plethysmography and mouth occlusion pressure (p0.1)].

Spirometric, bodyplethysmographic and mouth occlusion results of 9 healthy probands were measured 9 - 11 times over a total of 28 - 39 days. Interindividual predicted values based on large studies show SDs of +/- 20 %, which is not acceptable for the judgement of individual values. Individual values are much less scattered (SD +/- 10 %). Each test person showed a differing individual range of 75 - 140 %. Functional basic facts can be derived from the different levels of individual values. Early changes in the individual range are of special interest. For the evaluation of individual results the earliest possible basic values are of importance.

Adolescent↗

[Accuracy of measurement and comparability of anterior rhinomanometry and whole body plethysmography in determination of nasal resistance. Studies with a mechanical model].

The degree of accuracy of anterior rhinomanometry and the plethysmographic method in determining nasal resistance was examined in a mechanical model. The plethysmographic method allows a precise estimation of nasal resistance. It was found that the absolute variation of the plethysmographically measured values is not greater than 5%. Anterior rhinomanometry as described by Bachmann (2) allows a valid estimation of the pressure-flow relation. Here, too, inaccuracy remains within a range of 5% if the values are recorded with an X-Y-plotter. With the system developed by EVG, a microprocessor-controlled analysis is also possible. The flow rate is measured at pressure rates of 75, 150, and 300 Pa. Inconstancies in respiratory flow cause deviations from the correct pressure-flow graph. Should these deviations accidentally coincide with the predefined points of evaluation these erroneously achieved results will be assumed to be representative for the whole graph. This analytical fault has meanwhile been corrected by interpolating the points at the predefined pressure rates. Due to the differences in analytic techniques the methods of determining nasal resistance are not comparable in practice. The authors therefore recommend that, in addition to the usual results of analysis, average value of nasal resistance be determined for each measuring procedure. Today, this can be done without any problem by using microprocessors.

Airway Resistance↗

Blood pressure measurement of all five fingers by strain gauge plethysmography.

The aim of the present paper was to study the methodological problems involved in measuring systolic blood pressure in all five fingers by the strain gauge technique. In 24 normal subjects, blood pressure at the proximal phalanx of finger I and both at the proximal and the intermediate phalanx of the other fingers was measured using a 24-mm-wide cuff. Blood pressure at the proximal phalanx was higher than that at the intermediate phalanx in all fingers except finger V. The difference of blood pressure values corresponded well with circumference of the finger. In 15 normal subjects, blood pressure at the proximal phalanx was compared in fingers I, III, IV, and V, using 16, 20, 24 and 24 mm wide cuffs. Finger blood pressure was closest to arm systolic blood pressure when a 24-mm or 27-mm-wide cuff was used in fingers I, III, and IV, and with a 20-mm-wide cuff in finger V. As the standard deviation of the mean values was larter with the 27-mm-wide cuff than with the 24-mm-wide cuff, the 24-mm-wide cuff was considered to be most suitable for clinical use in fingers I, II, III, and IV. By using the 20-mm-wide cuff in finger V and the 24-mm-wide cuff in the other fingers, normal value of finger blood pressure was determined for both proximal and intermediate phalanxes.

Adolescent↗

Simultaneous application of differential servo-oscillometry and volume-clamp plethysmography for continuous non-invasive recording of the finger blood pressure response to a hand postural change.

Continuous blood pressure recordings obtained by the volume-clamp method (Finapres 2300 BP monitor, Ohmeda, USA) were compared with measurements made by using the modified oscillometric method (UT9201 beat-to-beat monitor, University of Tartu, Estonia) in normal subjects during a hand postural change. Changes in the local blood pressure were induced in 11 healthy volunteers by passive elevation of the hand by 40 cm and lowering it again after one minute. We did not reveal a statistically significant difference between the group-averaged responses of the oscillometric finger mean blood pressure measurement device and those of Finapres during this test. The difference UT9201 minus Finapres equalled -1.3 +/- 3.1 mm Hg (p = 0.15). Blood pressure responses were similarly tracked by both beat-to-beat finger blood pressure monitors despite the considerable variability in the shape of the subjects' individual responses.

Adult↗

Respiratory inductive plethysmography accuracy at varying PEEP levels and degrees of acute lung injury.

BACKGROUND AND OBJECTIVE: This study was performed to assess the accuracy of respiratory inductive plethysmographic (RIP) estimated lung volume changes at varying positive end-expiratory pressures (PEEP) during different degrees of acute respiratory failure. METHODS: Measurements of inspiratory tidal volume were validated in eight piglets during constant volume ventilation at incremental and decremental PEEP levels and with increasing severity of pulmonary injury. RIP accuracy was assessed with calibration from the healthy state, from the disease state as the measurement error was assessed, and at various PEEP levels. RESULTS: Best results (bias 3%, precision 7%) were obtained in healthy animals. RIP accuracy decreased with progressing degrees of acute respiratory failure and was PEEP dependent, unless RIP was calibrated again. When calibration was performed in the disease state as the measurement error was assessed, bias was reduced but precision did not improve (bias -2%, precision 9%). CONCLUSIONS: RIP accuracy is within the accuracy range found in monitoring devices currently in clinical use. Most reliable results with RIP are obtained when measurements are preceded by calibration in pulmonary conditions that are comparable to the measurement period. When RIP calibration is not possible, fixed weighting of the RIP signals with species and subject size adequate factors is an alternative. Measurement errors should be taken into account with interpretation of small volume changes.

Acute Disease↗

The use of inductive plethysmography in the study of the ventilatory effects of respirator wear.

The authors recently developed an ambulatory system, in which a self-contained respiratory inductive plethysmograph (RIP) was used, to measure noninvasively the volume and time components of breathing. Since it does not use nasal or oral devices, such a system is particularly suitable for use in studying the effects of respiratory protective masks on respiratory parameters. In order to validate this portable system, 22 healthy subjects were exercised on a treadmill; RIP and pneumotachographic minute ventilation measurements were compared. A short, graded submaximal exercise protocol was run 3 times by each subject under each of the following conditions: no oral mouthpiece; oral mouthpiece with pneumotachograph; and wearing an industrial protective mask (half facepiece, twin cartridge). Chest and abdominal RIP signals, a time signal and either a pneumotachograph or heart-rate signal were recorded on a small cassette recorder worn at the belt. The data tapes were later edited and analyzed by computer. Data from 5 subjects were excluded because of equipment malfunction. The average error in RIP-measured ventilation compared to values simultaneously measured by a pneumotachograph in the 17 remaining subjects over all exercise levels was -3.16%. Marked variability (SD = 11.26%), however, was found in individuals at different exercise levels and especially between subjects. Use of a respirator was associated with a decreased respiratory frequency, an increased tidal volume and minute ventilation, and an unchanged heart rate. At present, the portable RIP system has substantial variability that limits its ability to measure ventilation accurately.

Humans↗

Reliability of respiratory inductive plethysmography for measuring tidal volume during exercise.

This study was designed to determine the reliability of measurements of respiratory volumes obtained with a respiratory inductive plethysmograph (RIP) during exercise. Tidal volumes (VT) from the RIP were compared with simultaneous flowmeter volumes in 8 healthy subjects at 5 incremental work rates of 60, 90, 120, 150, and 180 W during cycling and treadmill exercise. During cycling, average RIP and flowmeter values did not differ significantly at work rates below 180 W for 63% of the subjects. Average RIP and flowmeter VT were similar at work rates below 180 W for 50% of the subjects, and for 83% of the subjects at intensities below 150 W. The variability in these results may be attributed to several factors including RIP calibration errors and slippage of the RIP elastic bands containing the inductive coils. Correlations of breath-by-breath flowmeter and RIP VT were significant for subjects during cycling (R = 0.73, P < 0.05) and treadmill exercise (R = 0.78, P < 0.05). These findings suggest that the RIP should be considered a semi-quantitative method for measurements of tidal volume during exercise with and without respirator wear.

Adult↗