Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Odontometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48Linked to original sources

Identifying multiplanar root canal curvatures using stainless-steel instruments.

Information obtained from careful observation of stainless-steel hand file deformation can be a critical step in efficient root canal space debridement. Secondary and tertiary canal curvatures that occur most often in the proximal view have been reported in the literature. Except in teeth that are clinically rotated, there is currently no method for observing the proximal view of root canal systems. This article presents a simple clinical procedure for detecting the three-dimensional anatomy of root canal spaces. We refer to the procedure as file molding.

Dental Instruments↗

An in vivo comparison of two frequency-based electronic apex locators.

The purpose of this study was to compare the accuracy of a two-frequency (Root ZX) and a five-frequency (Endo Analyzer Model 8005) electronic apex locator under clinical conditions. Thirty-two teeth planned for extraction were used. The coronal portion of each canal was flared using Gates Glidden drills and Orifice Shapers. The canals were irrigated with 2.6% sodium hypochlorite. A K-type file was used to determine a separate working length in each canal using the electronic apex locators. The teeth were extracted and the apical 4 mm of each root canal was exposed along the long axis of the tooth. Photographic slides of each canal were projected and the file position in relation to the minor diameter was determined by two investigators. The mean distance between the electronic apex locator working length and minor diameter was 1.03 mm for the Endo Analyzer and 0.19 mm for the Root ZX. A paired sample t test showed that the Endo Analyzer had significantly longer readings beyond the minor diameter than the Root ZX (p < 0.0001). The ability to locate the minor diameter (+/- 0.5 mm) was 90.7% for the Root ZX and 34.4% for the Endo Analyzer Model 8005.

Adult↗

Patient safety during endodontic therapy using current technology: a case report.

It is an accepted safety practice to take precautions during endodontic treatment to prevent aspiration or swallowing of instruments (1). The placement of a rubber dam is considered the standard of care (2, 3). With the advent of new endodontic devices, new safety challenges have arisen and must be considered in addition to the placement of a rubber dam. A case report is presented that emphasizes the importance of patient safety and suggests precautions to prevent any safety-related mishaps during treatment.

Dental Instruments↗

Anatomy of the pulp-chamber floor.

Locating the number and position of orifices on pulp-chamber floors can be difficult. This is especially true when the tooth being treated is heavily restored, malposed, or calcified. After evaluating 500 pulp chambers of extracted teeth, new laws for finding pulp chambers and root-canal orifices are proposed. The use of these laws can aid in the determination of the pulp-chamber position and the exact location and number of root canals in any individual tooth.

Color↗

In vitro evaluation of the accuracy of three electronic apex locators.

The accuracy of three electronic apex locators (EALs) (Justy II, Root ZX, and Neosono Ultima EZ) is evaluated, together with the concordance of the measurements obtained by two different operators. Twenty single-root human teeth were used, sectioning the crown to gain access to the root canal. A first operator (A) determined the reference (or control) length (corresponding to the actual length) for each tooth, after which all teeth were measured individually and independently by the other two operators (B and C). The results obtained with each EAL and by each operator were in turn compared with the corresponding control length. The statistical analysis of the results showed EAL reliability in detecting the apex to vary from 80% to 85% and 85% to 90% (depending on the operator) for the Justy II and Neosono systems, respectively, whereas reliability was found to be 85% for the Root ZX device. These results, combined with a high interobserver concordance, suggest electronic root canal measurement to be an objective and acceptably reproducible technique.

Chi-Square Distribution↗

Morphological measurements of anatomic landmarks in human maxillary and mandibular molar pulp chambers.

The aim of this in vitro study was to measure critical morphology of molar pulp chambers. One hundred random human maxillary and mandibular molars (200 teeth in total) were used. Each molar was radiographed mesiodistally on a millimeter grid. Using a stereomicroscope, the measurements were read to the nearest 0.5 mm. Results were as follows (mean, mm): pulp chamber floor to furcation, maxillary = 3.05 +/- 0.79, mandibular = 2.96 +/- 0.78; pulp chamber ceiling to furcation, maxillary = 4.91 +/- 1.06, mandibular = 4.55 +/- 0.91; buccal cusp to furcation, maxillary = 11.15 +/- 1.21, mandibular = 10.90 +/- 1.21; buccal cusp to pulp chamber floor, maxillary = 8.08 +/- 0.88, mandibular = 7.95 +/- 0.79; buccal cusp to pulp chamber ceiling, maxillary = 6.24 +/- 0.88, mandibular = 6.36 +/- 0.93; and pulp chamber height, maxillary = 1.88 +/- 0.69, mandibular = 1.57 +/- 0.68. The pulp chamber ceiling was at the level of the cementoenamel junction in maxillary, 98%, and mandibular, 97% of the specimens. The measurements showing the lowest percentage variance were buccal cusp to furcation (approximately 11%) and buccal cusp to pulp chamber ceiling (approximately 14%). The measurements were similar for both maxillary and mandibular molars.

Dental Pulp Cavity↗

Evaluation of the root canal configurations of the mandibular and maxillary permanent teeth by gender in the Turkish population.

A key objective of successful nonsurgical endodontic treatment is obturation of the root canal systems. One factor in achieving this goal is the knowledge of possible root canal morphologies. Root canal morphology may exhibit variation as a result of many factors, including ethnic origin. In this study, 1400 male and 1400 female extracted mandibular and maxillary permanent teeth were evaluated for patterns in root canal morphology. The mandibular and maxillary teeth were divided into seven groups of tooth type (e.g. centrals, laterals, canines, first premolars, second premolars, first molars, and second molars), subdivided into gender, and classified by root canal morphologies. Vertucci's classification was taken as a reference during the evaluation. Although a majority of the specimens corresponded to this classification scheme, the analysis of this large data set revealed 14 additional root canal morphologies.

Bicuspid↗

Cross-sectional morphology and minimum canal wall widths in C-shaped roots of mandibular molars.

The cross-sectional canal morphology and minimum widths of buccal and lingual canal walls were studied in 20 mandibular molars with C-shaped roots and canal orifices. The roots were mounted in clear resin blocks and sectioned transversely at 1-mm intervals. A total of 154 cross-sections were evaluated with an image analyzer. Twelve different longitudinal canal configurations were identified. The most prevalent were types 1-2 and 1-2-1 with each type occurring in four roots. Evaluation of the cross-sectional morphology showed that the configurations were complete "C" (27%), incomplete C (64%), and non-C (9%). The mean value for the minimum width of the lingual canal wall was 0.58 +/- 0.21 mm and the buccal wall was 0.96 +/- 0.26 mm. This suggests that there is a higher risk of root perforation at the thinner lingual walls of C-shaped canals during shaping and post canal preparation procedures. Both buccal and lingual canal walls were frequently narrower at mesial locations.

Adult↗

C-shaped canal system in mandibular second molars: Part II--Radiographic features.

The purpose of this study was to investigate the relation between the radiographic features of C-shaped mandibular second molars and the cross-sectional shapes of their root canal system. Fifty-eight extracted mandibular second molars with fused roots were collected from a native Chinese population. The teeth were scanned at 0.5-mm interval thickness by micro-computed tomography (microCT) and observed at 11 levels. The 54 teeth that possessed a C-shaped canal system were further examined. Their radiographic appearances were classified into three types according to discernible radiographic features. The results were subject to the Kruskal-Wallis statistical test. In these 54 molars, 16 teeth (29.63%) showed a type I radiographic image, 22 (40.74%) type II, and 16 (29.63%) type III. In the type I category, the C1 and C4 canal configurations were mostly found in the apical area. Categories C2 and C3 were the main configurations in the middle and apical areas in type II and III. The type III had more C2 canals in middle area than type II. These results suggested that it was possible to predict the presence and the configuration of C-shaped canal system by the radiographic appearance.

Anatomy, Cross-Sectional↗

C-shaped canal system in mandibular second molars: Part I--Anatomical features.

The purpose of this study was to investigate the anatomical features of C-shaped root canal system in mandibular second molars using micro-computed tomography (microCT). Fifty-eight extracted mandibular second molars with fused roots were collected from a native Chinese population. The teeth were scanned into layers of 0.5-mm thickness by microCT and measurements were made at eleven levels. The ratio of the depth of the deepest part of the groove to the buccal-lingual thickness of the cross-section of the root was calculated for each tooth. The canal shapes of the scanned cross-sections were assessed and classified according to a modified Melton's method. Results were subject to the Kruskal-Wallis test. Of the 58 molars, 54 had a C-shaped canal system with a mean groove-to-thickness ratio of 47.96%; the four teeth without a C-shaped canal had a mean ratio of 14.82%. Most orifices (98.1%) were found within 3 mm below the cementoenamel junction. Of teeth with a C-shape canal system, a majority demonstrated an orifice with an uninterrupted "C" configuration. Seventeen canals divided in the apical portion, most of which did so within 2 mm from the apex. The cross-sectional shape varied drastically along the length of the canal. Teeth with a high groove-to-thickness ratio had at least one section with C1, C2, or C3 configuration. The canal shape in middle and apical thirds of C-shaped canal systems could not be predicted on the basis of the shape at the orifice level. Section 2 of this paper addressed the correlation between the radiographic appearance and these microCT images.

Anatomy, Cross-Sectional↗

The effect of mesio-distal chamber dimension on access preparation in mandibular incisors.

Because the pulp chamber of a young mandibular incisor flares coronally in a mesio-distal dimension, the access form pictured by a number of authors is triangular in shape. As a person ages, the chamber recedes and the access shape becomes oval in form consistent with a canal system that is primarily bucco-lingual in orientation. Endodontic literature generally recommends either the triangular or oval access shape without acknowledging that both are appropriate at a given time in the life of the individual. The question addressed by this study is when does the pulp chamber loose its coronal flare to become primarily oval in shape, and as a consequence of this change, when should the access form go from triangular to oval. It was concluded that by the age of 40 the canal has decreased in size sufficiently to justify in routine cases an oval preparation of less than 2 mm mesio-distal width.

Adult↗

Effect of root canal size and external root surface morphology on fracture susceptibility and pattern: a finite element analysis.

The aim of the study was to determine the extent to which canal size, radius of curvature and proximal root concavity influence fracture susceptibility and pattern. A standardized cross-section of the mid-root region of a mandibular incisor was created by averaging the dimensions of 10 extracted teeth, and then the basic finite element analysis (FEA) model was created. By varying canal diameter, shape, and proximal concavity, these factors could be examined for roles in fracture susceptibility and pattern. The factors all interact in influencing fracture susceptibility and pattern, with dentin thickness not the only determining factor. The removal of dentin does not always result in an increased fracture susceptibility.

Dental Pulp Cavity↗

Determining the optimal obturation length: a meta-analysis of literature.

The purpose was to aid in determining termination of instrumentation and obturation. A meta-analysis was conducted as to success/failure of different obturation lengths. Inclusion criteria were (a) minimum follow-up of 2 yr, (b) data on obturation length, (c) definition of success/failure, (d) available data on success/failure, (e) radiographic evaluation. Correlations were made as to success/failure as related to length of obturation from the apex. When comparing group A (obturated 0-1 mm from apex) versus group C (obturated past apex) using the DerSimonian and Laird estimates, group A showed a marginally better (p < 0.10) success rate than group C by 28.8%. Group A had better success than group B (obturated >1 mm short); the difference was insignificant. The results were similar after controlling for study quality using a single random effects regression model. In conclusion, the meta-analysis indicated that a better success rate is achieved when treatment includes obturation short of the apex.

Dental Pulp Cavity↗

Shaping ability of RaCe rotary nickel-titanium instruments in simulated root canals.

This study assessed the shaping ability of RaCe rotary nickel-titanium instruments in simulated root canals. Forty simulated root canals consisting of four different shapes were prepared with RaCe rotary nickel-titanium instruments in a crowndown approach. Preoperative images were taken at the outset and postoperative images at various stages of preparation including at the conclusion of the shaping procedure. The combined images enabled assessment of aberrations and resin removal at various positions along the canal length. Overall, mean preparation time to size 40, .02 taper was 1.36 min. Thirty-three canals (83%) maintained the working length, three instruments deformed and no zips, perforations, or ledges were created. Under the conditions of this study RaCe rotary nickel-titanium instruments prepared simulated canals rapidly and successfully, with little change in working length and with few aberrations or instrument deformities.

Dental Alloys↗

Morphological measurements of anatomic landmarks in pulp chambers of human maxillary furcated bicuspids.

The aim of this in vitro study was to measure key morphological features of pulp chambers from furcated maxillary bicuspid teeth. There were 107 random human maxillary bicuspid teeth used. Each bicuspid was radiographed using the Trophy RVG digital imaging system and a Belmont Acuray X-ray at 70 kVp. Measurements were made using the Digipan measuring mode of the Trophy system. Results were mean (mm): pulp chamber floor to furcation: 1.85 +/- 0.85; pulp chamber ceiling to furcation: 4.61 +/- 1.04; cusp to furcation: 11.55 +/- 1.12; cusp to pulp chamber ceiling: 6.94 +/- 0.70; pulp chamber height: 2.76 +/- 0.97. The measurements showing the lowest percentage variance were: cusp to furcation (9.70%) and cusp to pulp chamber ceiling (10.09%). The only measurement that was statistically the same across maxillary molars, mandibular molars and bicuspids was measurement "B," pulp chamber ceiling to furcation. The critical distance from cusp tip to pulp chamber ceiling in bicuspids was approximately 7.00 mm.

Analysis of Variance↗

A comparative study of three different root canal curvature measurement techniques and measuring the canal access angle in curved canals.

In the first part of this study the Schneider (S), Weine (W), and Long-Axis (LA) techniques are used for comparing the measurement of canal curvature. One hundred mandibular first and second molar teeth were selected. Radiographs were taken after inserting size 10 K-files into the mesiobuccal root canals. The radiographic findings were digitized on a computer, and the three different curvature angles were measured from drawings of the same root canal and compared statistically. ANOVA showed that there were significant differences between the curvature angle values determined using each technique (p < 0.001). In the second part of this study the term "canal access angle" (CAA) was introduced and it was defined by examining the morphology of canal curvature. Canal length, curvature distance (y), curvature height (x), Schneider angle, and the newly defined CAA were evaluated statistically. Using a multiple regression analysis, the CAA was significantly related to x (p < 0.001) and y (p < 0.005). There was a positive correlation (r = 0.74) between the CAA and curvature height (x). The results indicated that the CAA is a more effective way of evaluating the root canal curvature.

Dental Pulp Cavity↗

Four major disasters in Aquitaine, France: use of odontologic techniques for identification.

The 4 mass disasters that have affected the Aquitaine region (France) in the previous 15 years are related through the specificity and the efficiency of dental methodology in identifying the victims. The results point to the decisive influence and the efficiency of dental methodology for identification of bodies that are burned or disfigured after an accident or a prolonged period in water.

Accidents, Traffic↗