Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Labor Stage, First”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48Linked to original sources

Transcutaneous electrical nerve stimulation for relief of parturition pain. A clinical report.

The purpose of this clinical report is to share procedures and results using transcutaneous electrical nerve stimulation (TENS) in the management of pain associated with labor and delivery. Although favorable reports of the use of TENS during labor have been published in Europe, its application in the United States to the labor and delivery process has received little attention and is relatively unknown. We decided to use US equipment in the obstetric department of a US community hospital to verify the European studies. Fifteen patients selected by two obstetricians evaluated the effectiveness of a 3M TENS unit Model 6240. The criteria for inclusion were willingness to try TENS and ability to understand the procedure. The patients served as their own control and turned the unit off for several contractions during the middle and late periods of the first stage of labor to judge the effectiveness of TENS. Twenty-four hours after delivery, a physical therapist recorded the subjective response of patients and obstetricians separately on a questionnaire, which gave a rating scale of poor, moderate, or excellent for relief. We found TENS provided some form of relief to 87 percent of the participants, and 20 percent reported excellent relief. Most participants expressed a willingness to use TENS if they gave birth again.

Adult↗

Fetal fibronectin: a new tool for the prediction of successful induction of labor.

OBJECTIVE: The Bishop score is the only available tool for predicting successful labor induction. Vaginal fetal fibronectin has been shown to predict which patients will enter labor spontaneously, usually within 2 weeks. This study was designed to determine whether fetal fibronectin can also predict the success of labor induction. STUDY DESIGN: Term patients undergoing labor induction had a single swab from the vagina tested for fetal fibronectin before initiation of cervical ripening or oxytocin. The swab was tested with a blinded qualitative immunoassay for fetal fibronectin (positive > or = 50 ng/ml). RESULTS: Of the overall 160 subjects, 108 had a positive and 52 had a negative fetal fibronectin result. Patients with a positive result had a lower cesarean section rate (15% vs 27%, p = 0.05) and shorter intervals to delivery, including first dose of prostaglandin to delivery interval (21.3 vs 35.8 hours, p = 0.0001) and first stage of labor (14.8 vs 21.2 hours, p = 0.0009). These differences remain similar even in nulliparous women with Bishop scores < or = 5, with patients with positive results having statistically shorter intervals to delivery and similar differences in cesarean section rates (22% vs 35%), although this difference was not significant. In this subgroup more than half the patients in the negative results group (11/20) were undelivered after 24 hours and were judged to require a second dose of prostaglandin compared with only 2 of 53 in the group with positive results (p = 0.000001). By stepwise logistic regression analysis the predictive ability of a positive result for fetal fibronectin was found to be independent of the Bishop score. CONCLUSIONS: Vaginal fetal fibronectin appears to be an efficacious new test that independently predicts which patients will have shorter and easier inductions of labor and lower cesarean section rates, even nulliparous patients with low Bishop scores. This test has the potential for clinical utility and cost reduction.

Adult↗

The role and comparison of two techniques of paracervical block for pain relief during suction evacuation for first-trimester pregnancy termination.

This prospective study assessed the role and compared two techniques of paracervical block (PCB) for pain relief during suction evacuation for first-trimester termination of pregnancy following cervical priming with misoprostol. One-hundred and thirty-five women undergoing suction evacuation up to 12 weeks of gestation were randomized into three groups: (a) 5 mL of 1% lignocaine injected at the 4 and 8 o'clock positions of the vaginal vault; (b) 5 mL of 1% lignocaine injected at the 4 and 8 o'clock positions of the cervix and (c) no PCB. Pain scores during PCB, cervical dilatation and during and after suction evacuation were compared among the three groups. The sedation and satisfaction levels were also compared. There were no statistically significant differences in the pain levels during PCB, cervical dilatation and suction evacuation and in the satisfaction levels among the three groups. Patients with a lighter sedation level experienced more pain. In conclusion, PCB did not improve the pain levels during first-trimester suction termination of pregnancy after cervical priming with misoprostol and use of intravenous sedation, regardless of whether the local anaesthetic was injected into the cervix or the vaginal vault.

Abortion, Induced↗

[The effect of spasmolytics on dilatation of the uterine cervix].

UNLABELLED: Spasmolytics and spasmoanalgetic mixtures are administered to facilitate dilatation of the cervix during delivery and to shorten the first stage of labour. This medication is used in 70% deliveries at the 1st Dept. of Obstetrics and Gynaecology Masaryk University in Brno. The aim of the study was to analyze the spasmolytic effect on the process of cervix dilatation. The study comprises 108 uncomplicated deliveries (52 deliveries with spasmolytics and 56 deliveries without). We analyzed the effect of spasmolytics on the cervix, process of labour and outcome of delivery. Six kinds of spasmolytics were used, administered from once to four times during labour and most of them (85%) in the latent phase of the first stage of labour. In the group with spasmolytics there was statistically insignificant by prolonged active phase of the first stage of labour (126 vs 104 minutes) and more frequent administration of Oxytocin. Others parameters such as length of the second stage of labour, rate of birth injuries, the 1st minute Apgar score less than 7 and the necessity of neonatal resuscitation did not differ in the two groups. CONCLUSIONS: The application of spasmolytics did not significantly affect the process of delivery.

Adult↗

Bishop score and risk of cesarean delivery after induction of labor in nulliparous women.

OBJECTIVE: To quantify the risk and risk factors for cesarean delivery associated with medical and elective induction of labor in nulliparous women. METHODS: A prospective cohort study was performed in nulliparous women at term with vertex singleton gestations who had labor induced at 2 obstetrical centers. Medical and elective indications and Bishop scores were recorded before labor induction. Obstetric and neonatal data were analyzed and compared with the results in women with a spontaneous onset of labor. Data were analyzed using univariate and multivariable regression modeling. RESULTS: A total of 1,389 women were included in the study. The cesarean delivery rate was 12.0% in women with a spontaneous onset of labor (n = 765), 23.4% in women undergoing labor induction for medical reasons (n = 435) (unadjusted odds ratio [OR] 2.24; 95% confidence interval [CI] 1.64-3.06), and 23.8% in women whose labor was electively induced (n = 189) (unadjusted OR 2.29; 95% CI 1.53-3.41). However, after adjusting for the Bishop score at admission, no significant differences in cesarean delivery rates were found among the 3 groups. A Bishop score of 5 or less was a predominant risk factor for a cesarean delivery in all 3 groups (adjusted OR 2.32; 95% CI 1.66-3.25). Other variables with significantly increased risk for cesarean delivery included maternal age of 30 years or older, body mass index of 31 or higher, use of epidural analgesia during the first stage of labor, and birth weight of 3,500 g or higher. In both induction groups, more newborns required neonatal care, more mothers needed a blood transfusion, and the maternal hospital stay was longer. CONCLUSION: Compared with spontaneous onset of labor, medical and elective induction of labor in nulliparous women at term with a single fetus in cephalic presentation is associated with an increased risk of cesarean delivery, predominantly related to an unfavorable Bishop score at admission. LEVEL OF EVIDENCE: II-2.

Adult↗

[Clinical importance of fetal pulse oximetry. I. Methodological evaluation. Multicenter study. French Study Group on Oximetry of Fetal Pulse].

OBJECTIVE: To evaluate the feasibility of intrapartum fetal pulse oximetry, the distribution of fetal oxygen saturation values, and the relation with the neonatal outcome in a population with an abnormal fetal heart rate (FHR). STUDY DESIGN: A prospective multicenter observational study, from June 1994 to November 1995. Fetal oxygen saturation was continuously recorded using a Nellcor N-400 fetal pulse oximeter in case of abnormal FHR during labor. Simultaneous readings of fetal oxygen saturation and of fetal blood analysis (FBA) were obtained at inclusion and before birth. Feasibility, adverse effects, distribution of fetal oxygen saturation values and relation with neonatal outcome were assessed. RESULTS: 74 patients were included. From 172 attempted sensor placements, the procedure was impossible in three cases and fetal oxygen saturation values were obtained in 164 cases (95.3%). Physicians considered sensor placement an easier task than FBA attempt (easy in 87.5% vs 78.9% for FBA, p = 0.03). The mean reliable signal time (+/- SD) was 64.7 +/- 32% during the first stage. There were no serious adverse effects in the study population. The mean fetal oxygen saturation during the first stage of labor was 42.2 +/- 8.0% (10th-90th centile range: 30-53%). Fetal oxygen saturation was significantly correlated with scalp pH (r = 0.29; p = 0.01) but not with neonatal umbilical artery pH or gas values. There was a significant association between a low fetal oxygen saturation (< 30%) and a poor neonatal condition. CONCLUSION: The feasibility of fetal pulse oximetry is satisfactory in clinical practice. It is easy to use and provides a fair rate of recorded values, even in a population with suspicion of fetal distress. A low fetal oxygen saturation is significantly associated with an abnormal neonatal outcome.

Adult↗

Deceleration/contraction ratios as an index of fetal health during labor.

Internal FHR tracings of 259 patients with variable decelerations and 49 with late decelerations were analyzed for frequency and severity of the pattern in an attempt to correlate with fetal pH or Apgar score at 1 minute. A significant increase in the risk of fetal acidosis was associated with a frequency of greater than 30% variable decelerations and 20% late decelerations. It also increased with the increase of severity of the pattern. Variable decelerations are not good predictors of Apgar scores less than or equal to 6 at 1 minute, but late decelerations are predictive when they occur more than 20% of the time. The fetus with variable decelerations a normal pH can be observed through the first stage of labor with a high degree of confidence. However, when a 20% or more moderate-to-severe late deceleration/contraction ratio is present, intervention is necessary even if scalp blood pH is normal. The FHR deceleration/uterine contraction (UC) ratio is a simple bedside technique for assessing fetal outcome.

Acidosis↗

The use of oral misoprostol for pre-abortion cervical priming: a randomised controlled trial of 400 versus 200 microg in first trimester pregnancies.

OBJECTIVE: To compare the impact of 200 and 400 microg oral misoprostol on pre-operative cervical priming in both primi- and multigravidae prior to first trimester termination of pregnancy. Pre-operative cervical dilatation and bleeding were assessed. DESIGN: Randomised controlled trial. SETTING: Norwegian university teaching hospital. SAMPLE: Five hundred and fifty-one women undergoing surgical termination of pregnancy between 7 and 12 weeks of gestation. METHODS: Patients were randomised to either 200 or 400 microg of oral misoprostol 10-16 hours before vacuum aspiration. The degree of cervical dilatation prior to abortion by vacuum aspiration was measured. Pre-operative bleeding and pain were recorded and vaginal bleeding was measured. MAIN OUTCOME MEASURES: Degree of pre-operative cervical dilatation and pre-operative bleeding. RESULTS: The mean cervical dilatation was 5.8 mm (SD 1.7) for the women who received 400 microg misoprostol and 5.4 mm (SD 1.4) for those who received 200 microg (P= 0.004). The pre-operative dilatation was larger in multigravidae than in primigravidae in both dosage groups. The odds ratio (OR) of pre-operative bleeding was 3.3 (95% confidence interval [CI] 2.1-5.0) in the 400 microg dosage group, as compared with the group receiving 200 microg misoprostol. The occurrence of bleeding was dose-dependent. Frequency of bleeding was similar in multigravidae compared with primigravidae in the 400 microg dosage group, whereas the occurrence of bleeding was less in primigravidae than multigravidae in the 200 microg dosage group. Only 89 out of 551 patients bled one or more grams. The volumes measured were not statistically significantly different. Complications were minor, and were distributed equally between the two dosage groups. CONCLUSIONS: The 200 microg oral misoprostol compared with the 400 microg oral misoprostol given 10-16 hours before first trimester surgical abortions results in less pre-operative vaginal bleeding and in a statistically, although not clinically significant reduction in cervical dilatation.

Abortifacient Agents, Nonsteroidal↗

Transvaginal sonographic assessment of cervical dynamics during the third trimester of normal pregnancy.

BACKGROUND: To obtain a normogram of measurements of the uterine cervix by transvaginal sonography during the third trimester of normal primiparous pregnancies and to relate these measurements to the events surrounding labor. METHODS: A prospective observational study, set in Guangzhou, Peoples Republic of China, was undertaken. Fifty-five normal nulliparous Chinese women with singleton pregnancies were studied from 30 weeks gestation until delivery. Serial transvaginal ultrasound examinations were performed at 30, 32, 34 and 36 weeks gestation and weekly thereafter. RESULTS: There was a significant correlation between gestational age and cervical length and width. Funnelling of the internal os was present in 25% of cases, and its earliest appearance was at 36 weeks. There was no consistent relationship between funnel length and width and gestational age. The duration of the first stage of labor was inversely correlated with the last ultrasound measurement of cervical length, but there was no relationship with either cervical width nor the presence of funnelling. The cervical changes in this population differed from those found in Caucasians. CONCLUSIONS: There is a direct relationship between both cervical width and length and gestational age and an inverse relationship with cervical length and the duration of labor. Funnelling of the internal os was not a predictor of the early onset of labor. The dimensions and features of the Asian cervix differ from those of the Europeans, and this should be considered when conducting further studies of a similar nature.

Cervix Uteri↗

Interrelationships among abnormal cardiotocograms in labor, meconium staining of the amniotic fluid, arterial cord blood pH, and Apgar scores.

A prospective study of the relationships among fetal heart rate pattern, meconium staining of the amniotic fluid, umbilical cord artery pH, and Apgar score was carried out in 1219 consecutive births. Interpretable cardiotocogram patterns and cord arterial pH and blood gas analysis were obtained in 698 cases. The sensitivity of an abnormal cardiotocogram at any time for acidosis (more than 1 SD below the mean, pH less than 7.17) was 80%, and for severe acidosis (more than 2 SDs below the mean, pH less than 7.085) was 83%. However, the predictive value was low, and 32% of fetuses had an abnormal cardiotocogram but no acidosis. If only cardiotocogram abnormality in the first stage of labor was considered, sensitivity was still 47% for acidosis and 67% for severe acidosis, and the false-positive rate was reduced to only 14%. We attempted to improve the prediction of acidosis by including meconium staining of the amniotic fluid, but 65% of the variation in umbilical cord artery pH and 72 and 86% of the variation in 1- and 5-minute Apgar scores, respectively, remained unexplained. In light of these poor correlations, the current practice of considering cardiotocogram abnormality, meconium staining of the amniotic fluid, acidosis, and low Apgar scores as indicating one single disorder, "fetal distress," is not valid.

Acidosis↗

Multicenter study on the clinical value of fetal pulse oximetry. I. Methodologic evaluation. The French Study Group on Fetal Pulse Oximetry.

OBJECTIVE: Our purpose was to evaluate the feasibility of intrapartum fetal pulse oximetry, the distribution of fetal oxygen saturation values, and the relationship with the neonatal outcome in a population with an abnormal fetal heart rate. STUDY DESIGN: A prospective multicenter observational study was performed from June 1994 to November 1995. Fetal oxygen saturation was continuously recorded with use of a Nellcor N-400 fetal pulse oximeter in case of an abnormal fetal heart rate during labor. Simultaneous readings of fetal oxygen saturation and fetal blood analysis were obtained at inclusion and before birth. Feasibility, adverse effects, distribution of fetal oxygen saturation values, and relationship with neonatal outcome were assessed. RESULTS: One hundred seventy-four patients were included. From 172 attempted sensor placements, the procedure was impossible in three cases and fetal oxygen saturation values were obtained in 164 cases (95.3%). Physicians considered sensor placement an easier task than an attempt at fetal blood analysis (easy in 87.5% vs 78.9% for fetal blood analysis, p = 0.03). The mean reliable signal time (+/- SD) was 64.7% +/- 32% during the first stage. There were no serious adverse effects in the study population. The mean fetal oxygen saturation during the first stage of labor was 42.2% +/- 8.0% (10th to 90th percentile range 30% to 53%). Fetal oxygen saturation was significantly correlated with scalp pH (r = 0.29, p = 0.01) but not with neonatal umbilical artery pH or gas values. There was a significant association between low fetal oxygen saturation (< 30%) and poor neonatal condition. CONCLUSION: The feasibility of fetal pulse oximetry is satisfactory in clinical practice. It is easy to use and provides a fair rate of recorded values, even in a population with suspicion of fetal distress. A low fetal oxygen saturation is significantly associated with an abnormal neonatal outcome.

Adult↗

Epidural infusions for labor analgesia: a comparison of 0.2% ropivacaine, 0.1% ropivacaine, and 0.1% ropivacaine with fentanyl.

BACKGROUND AND OBJECTIVES: Epidural infusion of 0.2% ropivacaine is recommended by the manufacturer for labor analgesia, but lower concentrations may be effective. The objective of this study was to compare 0.1% ropivacaine with 0.2% ropivacaine and to examine the effect of addition of fentanyl. METHODS: In a randomized double-blind study, 58 nulliparous laboring parturients had epidural analgesia established with 0.2% ropivacaine and were then randomized to receive one of the following epidural infusions at 10 mL/h: 0.2% ropivacaine (group R2, n = 19), 0.1% ropivacaine (group R1, n = 19), or 0.1% ropivacaine with 2 microg/mL fentanyl (group RF, n = 20). Supplementary analgesia was provided on request with 5-mL boluses of 0.2% ropivacaine. RESULTS: All solutions provided effective analgesia during early labor, with all groups requiring similar numbers of supplementary top-ups. Visual analog pain scores in groups R2 and RF were equivalent and lower than in group R1 (P =.006). Hypotension was more frequent in group RF compared with groups R2 and R1 (P =.014). Patient and midwife satisfaction and obstetric and neonatal outcomes were similar among groups. Maternal venous plasma concentrations of ropivacaine were greater in group R2 compared with groups R1 and RF (P =.008), but umbilical venous concentrations were similar. CONCLUSIONS: We conclude that epidural infusion of 0.1% ropivacaine alone at 10 mL/h provided adequate analgesia in the first stage of labor, and that the addition of 2 microg/mL fentanyl to that concentration improved analgesia to a quality similar to 0.2% ropivacaine alone.

Adult↗

Periviable birth at 20 to 26 weeks of gestation: proximate causes, previous obstetric history and recurrence risk.

OBJECTIVE: Early preterm birth at 20 to 26 weeks of gestation (periviable birth) carries extreme risks of infant death and morbidities. Prevention of periviable birth could improve infant outcomes significantly. We sought to characterize the causes of periviable birth and to determine whether periviable birth can be predicted by previous pregnancy outcome. STUDY DESIGN: We evaluated 104,921 pregnancies (1974-2004) and assessed the frequency and causes of periviable birth. Women who were delivered of both their first and second pregnancies at >20 weeks of gestation at our institution were identified. Predictive values of the first pregnancy outcomes for second pregnancy outcomes were determined. RESULTS: Periviable birth complicated 1981 deliveries (1.9%). Seventy-nine percent of the women with periviable births had no history of periviable births; 44% of the women had no previous deliveries, and 35% of the women had previous term deliveries only. Causes of periviable birth were labor (36%), premature rupture of membranes (34%), bleeding (10%), and preeclampsia (4%). Four percent of the gestations were multiple gestations. Among 7970 pregnancies at >20 weeks of gestation, periviable birth in the first pregnancy was associated with preterm birth and periviable birth in the second pregnancy (35.6%, 6.9%; relative risk, 3.3 and 8.6; P < .0001). Periviable birth and preterm birth in the first pregnancy were insensitive for periviable birth in the second pregnancy (8.8%, 36.8%, respectively). CONCLUSION: Although periviable birth is associated with subsequent periviable birth and preterm birth, preterm birth and periviable birth are insensitive markers for recurrences in the next pregnancy. Early pregnancy or preconceptional markers for prediction of periviable birth are needed.

Female↗

[Causes of labor initiation in man: role of oxytocin and prostaglandins].

Questions related to the mechanism of human labor are of central clinical importance nowadays, since the majority of perinatal mortality and morbidity is due to disregulation of uterine contractility mainly premature onset of labor. During delivery of spontaneous or induced onset endogenous prostaglandin F-synthesis increases dramatically and reaches a maximum at the time of placental separation. These increased amounts of prostaglandin F and E lead to myometrial contractions and to a reduction of the cervical resistance. Post partum, prostaglandins lead to the contracture of the myometrium necessary for separation and expulsion of the placenta. The precise causes for initiation of parturition at term however have not been fully elucidated. The present review presents a theory in which oxytocin acts as central trigger of labor. At the end of human pregnancy a marked rise in the concentration of oxytocin receptors in the myometrium can be observed, thereby leading to an increased sensitivity of the myometrium towards oxytocin. Therefore, a small increase of the circulating oxytocin concentration in the maternal peripheral blood (for example through addition of fetal oxytocin) is sufficient to induce contractions. Apart from inducing contractions, oxytocin also leads to a stimulation of prostaglandin synthesis through receptors in the decidua. Prostaglandins themselves lead to further contractions, soften the cervix, induce gap-junctions and sensitize the myometrium further for oxytocin, thereby leading to a progressive cervical dilatation. At the end of the first stage of labor, the membranes usually rupture leading to a further increase in prostaglandin synthesis, so that the mechanism can no longer be interrupted exogenously.(ABSTRACT TRUNCATED AT 250 WORDS)

Cervix Uteri↗

The site of action of epidural fentanyl infusions in the presence of local anesthetics: a minimum local analgesic concentration infusion study in nulliparous labor.

UNLABELLED: We have previously demonstrated that continuous epidural infusions of fentanyl without local anesthetics elicit analgesia by a systemic mechanism. In this study, we examined the hypothesis that, in the presence of epidural bupivacaine, continuous infusions of epidural fentanyl elicit analgesia by a spinal mechanism. Forty-eight nulliparous women in active labor participated in this prospective, randomized, double-blinded study. Women received lumbar epidural analgesia with 20-30 mL bupivacaine 0.125% until pain free. Subjects were then randomized to either IV or epidural (EPI) fentanyl infusion groups. Each infusion delivered fentanyl 30 microg/h. All women received an epidural infusion of bupivacaine at a rate of 20 mL/h, the concentration of which was determined by the response of the previous woman in the same group to the analgesic regimen used. Unlike previous studies that assessed the minimum local analgesic concentration (MLAC) for bolus administration at the initiation of analgesia, this study assessed MLAC(infusion) for the maintenance of analgesia throughout the first stage of labor. MLAC(infusion) was determined using the up-down sequential analysis described by Dixon and Massey. The MLAC(infusion) of epidural bupivacaine was 0.063% (95% confidence interval, 0.058-0.068) and 0.019% (95% confidence interval, 0.000-0.038) in the IV and EPI groups respectively. A continuous infusion of fentanyl was more than three times as potent when administered by the epidural than by the IV route. This marked increase in potency for the epidural route is highly suggestive for a predominantly spinal mechanism of action for infused epidural fentanyl under the conditions of this study. IMPLICATIONS: This study determined the median effective concentration for epidural infusions of bupivacaine during labor analgesia. Coadministered epidural fentanyl infusions were more than three times more potent than IV fentanyl infusions, suggesting a predominantly spinal mechanism of opioid action under these study conditions.

Adolescent↗

Visual effect of partogram designs on the management and outcome of labour.

A prospective study of 3 partogram designs was performed in 990 women in labour with singleton pregnancy. Partogram A, B and C showed a progressively flatter steepness of the curve of labour progression. Oxytocin was administered in 35.1% of partogram-A users, 45.9% of partogram-B users (p = 0.001) and 44.1% of partogram-C users (p = 0.035). Significantly fewer patients among the partogram-A users (10.2%) were administered oxytocin too early compared to 18.6% of partogram-B users and 20.5% of partogram-C users. Of those with spontaneous onset of labour, a significantly smaller total dose of oxytocin was administered to the partogram-A users compared to the other 2 groups. Ominous electrocardiotocographic fetal heart patterns were detected less frequently during the first stage of labour in partogram A users (0.4%) compare to partogram-B users (1.1%) and partogram-C users (3.0%). Significantly fewer infants born to partogram-A users had depressed Apgar scores at 1 and 5 minutes. Partograms displaying a flat graph, compared to a steep graph, were more often considered to have a slow progress of labour. Adoption of partograms showing a steep graph of progress of cervical dilatation is recommended.

Cervix Uteri↗

The addition of pethidine to epidural bupivacaine in labour--effect of changing bupivacaine strength.

The effects of varying the strength of bupivacaine used in epidurals for the relief of labour pain was examined. The trial randomly allocated sixty women in the first stage of labour to one of three groups. All women were of ASA status 1 or 2 and had uncomplicated pregnancies. Subjects in each group received pethidine 25 mg in 10 ml of either 0.125%, 0.1875%, or 0.25% bupivacaine. Pain scores for each patient were then assessed over the following thirty minutes. Duration of analgesia and subsequent dose requirements were examined. No difference in pain scores between groups at thirty minutes after injection of the test solutions was found. The 0.25% solution group did however have a more rapid onset of analgesia with the majority of patients in this group achieving their maximum effect between ten and twenty minutes after injection. Duration of analgesia was not prolonged by using the stronger solutions. This study suggests that when epidural pethidine 25 mg is added to local anaesthetic solutions of bupivacaine, adequate analgesia for the first stage of labour is achieved with the 0.125% bupivacaine solution. The use of stronger solutions of bupivacaine achieves no greater degree of analgesia nor longer duration of action, although the onset of analgesia may be faster with the stronger solutions. Further investigations are needed to determine if 25 mg of pethidine is the best choice of dose to use under these circumstances.

Adult↗

Continuous infusion epidural analgesia during labor: a randomized, double-blind comparison of 0.0625% bupivacaine/0.0002% fentanyl versus 0.125% bupivacaine.

The analgesic efficacy of the continuous epidural infusion of 0.0625% bupivacaine/0.0002% fentanyl was compared with the infusion of 0.125% bupivacaine alone in a randomized, double-blind study of nulliparous women. Each patient received, in sequence: 1) 3 ml of 0.5% bupivacaine with 1:200,000 epinephrine; 2) 6 ml of study solution 1 (bupivacaine-fentanyl group: 0.125% bupivacaine/0.0008% fentanyl; bupivacaine-only group: 0.25% bupivacaine alone); and 3) a continuous epidural infusion of study solution 2 at a rate of 12.5 ml/h (bupivacaine-fentanyl group: 0.0625% bupivacaine/0.0002% fentanyl; bupivacaine-only group: 0.125% bupivacaine alone). The epidural infusion was discontinued at full cervical dilatation, but patients who lacked perineal anesthesia received one or two 5-ml boluses of study solution 3 (bupivacaine-fentanyl group: 0.0625% bupivacaine alone; bupivacaine-only group: 0.125% bupivacaine alone). During the first stage of labor, 36 of 41 (88%) women in the bupivacaine-fentanyl group, and 37 of 39 (95%) women in the bupivacaine-only group, had analgesia of excellent or good quality (P = NS). During the second stage, 22 of 37 (59%) women in the bupivacaine-fentanyl group, and 23 of 35 (66%) women in the bupivacaine-only group, rated their analgesia as excellent or good (P = NS). Women in the bupivacaine-only group were more likely to have motor block at full cervical dilatation (P less than .001). There was no significant difference between groups in duration of the second stage of labor, duration of pushing, position of the vertex before delivery, method of delivery, Apgar scores, or umbilical cord blood gas and acid-base values.(ABSTRACT TRUNCATED AT 250 WORDS)

Analgesia↗