Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Knee Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48Linked to original sources

Risk factors for septic arthritis in patients with joint disease. A prospective study.

OBJECTIVE: To quantify potential risk factors for septic arthritis, in order to identify a basis for prevention. METHODS: The occurrence of potential risk factors for septic arthritis in patients with joint diseases attending a rheumatic disease clinic was prospectively monitored at 3-month intervals over a period of 3 years. Potential risk factors investigated were type of joint disease, comorbidity, medication, joint prosthesis, infections, and invasive procedures. The frequencies of risk factors in patients with and those without septic arthritis were compared using multiple logistic regression analysis. RESULTS: There were 37 patients with and 4,870 without septic arthritis. Risk factors for developing septic arthritis were age > or = 80 years (odds ratio [OR] = 3.5, 95% confidence interval [95% CI] 1.4-8.6), diabetes mellitus (OR = 3.3, 95% CI 1.1-10.1), rheumatoid arthritis (OR = 4.0, 95% CI 1.9-8.3), hip and/or knee prosthesis (OR = 15, 95% CI 4.1-54.3), joint surgery (OR = 5.1, 95% CI 2.2-11.9), and skin infection (OR = 27.2, 95% CI 7.6-97.1). CONCLUSION: These findings indicate that preventive measures against septic arthritis in patients with joint diseases should mainly be directed at those with joint prostheses and/or skin infection.

Age Factors↗

[Postoperative autotransfusion in primary knee replacement surgery].

OBJECTIVE: To assess the efficacy of postoperative autologous transfusion to reduce homologous blood transfusion needs in primary knee replacement surgery. PATIENTS AND METHODS: A prospective study was carried out in 33 consecutive patients with diagnoses of arthrosis scheduled for primary knee replacement surgery with postoperative autotransfusion using a CBCII Constavac-Stryker (Stryker Instruments, Michigan, USA) recovery system from June through October 2002. We analyzed patient age, sex, preoperative and postoperative (24 hours) hemoglobin and hematocrit values, autologous blood reinfused and homologous blood transfusion incidence rate (if hematocrit was below 25%). RESULTS: Of the 33 patients receiving postoperative autotransfusion, one also needed homologous blood transfusion (3%). The mean volume of filtered whole blood reinfused was 538.63+/-261.23 mL, 1100 mL being the largest volume reinfused. We observed no complications related to use of autotransfusion devices during the perioperative period. CONCLUSIONS: Postoperative autotransfusion as the only blood salvage technique in primary knee prosthesis surgery nearly eliminates homologous transfusion needs. In addition, it is a safe, simple procedure and has replaced our hospital's preoperative autologous transfusion procedure.

Aged↗

Poor outcomes of isolated tibial insert exchange and arthrolysis for the management of stiffness following total knee arthroplasty.

BACKGROUND: Severe stiffness after total knee arthroplasty is a debilitating problem. In patients with securely fixed and appropriately aligned components, arthrolysis of adhesions and exchange to a thinner tibial polyethylene insert may appear to be a reasonable and logical solution. We reviewed our experience with this procedure to determine its efficacy. METHODS: From 1992 through 1998, seven knees with marked stiffness after total knee arthroplasty were treated at our institution with arthrolysis of adhesions and conversion to a thinner tibial polyethylene insert. Only patients in whom the total knee prosthesis was well aligned, well fixed, and not associated with infection were included. There were five women and two men with a mean age at revision of sixty-one years (range, thirty-eight to seventy-four years). The average time to revision was twelve months, and the mean arc of motion prior to revision was 38.6 degrees (range, 15 degrees to 60 degrees ). The duration of follow-up after the insert exchange averaged 4.2 years (range, two to eight years). RESULTS: Mean Knee Society pain and function scores changed from 44 and 36.4 points preoperatively to 39.6 and 46 points at the time of final follow-up. Two knees were rerevised, one because of infection and the other because of aseptic loosening of the components. The five remaining knees were painful and stiff at the time of final follow-up. Four of these five knees were severely painful, and one knee was moderately and occasionally painful. The mean arc of motion of these five knees was 58 degrees (range, 40 degrees to 70 degrees ) at the time of final follow-up. CONCLUSION: Isolated tibial insert exchange, arthrolysis, and débridement failed to provide a viable solution to the difficult and poorly understood problem of knee stiffness in a group of carefully selected patients following total knee arthroplasty. We therefore have little enthusiasm for the continued use of this strategy.

Adult↗

Is radiation synovectomy for arthritis of the knee more effective than intraarticular treatment with glucocorticoids? Results of an eighteen-month, randomized, double-blind, placebo-controlled, crossover trial.

OBJECTIVE: To compare the clinical efficacy and safety of radiation synovectomy (RSO) with intraarticular (IA) yttrium-90 plus glucocorticoids (GCs) with the efficacy and safety of IA placebo yttrium plus GCs and to identify parameters that predict efficacy. METHODS: The knees of 97 patients with persistent arthritis despite outpatient treatment with IA GCs (n = 113 knees), were treated with either IA (90)Y plus GCs (50%) or IA placebo yttrium plus GCs (50%), followed by 3 days of bed rest in the hospital clinic, with splinting of the treated knee. Predominant diagnoses were undifferentiated arthritis (39%) and rheumatoid arthritis (32%). The clinical effect of therapy was assessed at 6 months using a composite change index (CCI; range 0-12). The primary outcome measure was the response rate (i.e., the percentage of joints with a CCI > or =6). Knees with persistent arthritis after 6 months underwent crossover therapy (51% of the (90)Y plus GCs group versus 45% of the placebo plus GCs group). Adverse effects and radiologic damage during followup were documented. RESULTS: Neither the response rate (48% in both groups), the mean CCI, nor the duration of remission was significantly different between groups. No clinically relevant short-term adverse effects were observed, except for progression of radiologic damage in 34% of the (90)Y plus GCs group versus 28% of the placebo plus GCs group (knee prosthesis placement in 8% versus 1%). The functional and radiologic status at study entry predicted the clinical effect. CONCLUSION: Treatment with (90)Y plus GCs with bed rest and splinting is not superior to IA GCs with bed rest and splinting. Over the short term, both treatments appeared to be safe, although a negative effect of (90)Y on cartilage and bone cannot be ruled out. Thus, it appears that RSO with (90)Y should no longer be considered the treatment of first choice for persistent arthritis of the knee.

Adult↗

Natural history and pathogenesis of the patella clunk syndrome.

INTRODUCTION: The current study aims to test the importance of the design of total knee prostheses in the 'patella clunk syndrome', which is one of the possible patellofemoral complications that can occur after total knee replacement. MATERIALS AND METHODS: Three patient cohorts consisting of 75 consecutive patients with 80 Insall-Burstein II (IB II) total knee replacements; 57 patients with 60 Anatomic Modular Knee (AMK) total knee replacements; and 103 patients with 106 Low Contact Stress Rotating Platform (LCS) total knee replacements were studied during the period from 1995 to 2001. This was an unselected series of elderly patients with knee arthritis of comparable demographics; we excluded only those patients receiving revision surgery. We recorded the preoperative and postoperative Knee Society scores, and the patient subgroups with postoperative patellofemoral complications were analysed in detail and were serially followed up. Radiological analysis followed the recommendation of the Knee Society, and the degree of pain was recorded on a visual analogue scale. Also, since the majority of patients with patella clunk syndrome had refused operation and were followed up for several years, an idea of the natural history of this condition was obtained. RESULTS: The relative frequency of occurrence of patella clunk syndrome among patients with the IB II, AMK, and LCS prostheses was 8.8%, 3.3%, and 0%, respectively. The calculated p value is strongly significant when comparing the IB II group with the LCS group (p<0.01); and of borderline significance when comparing the AMK with the LCS group (p=0.05); and not statistically significant between the IB II and AMK groups (p=0.19). Analysis of the results also showed that about half of the patients who underwent conservative treatment still had incapacitating symptoms after several years of follow-up, while the other half showed progressive improvement over time. CONCLUSION: Given a good surgical technique in component placement and debridement of the peripatella synovium, the design of a total knee prosthesis has a strong bearing on the incidence of the patella clunk syndrome. The natural history of the patella clunk syndrome reveals that for as yet uncertain reasons about 50% will improve with time even when given conservative treatment.

Aged↗

[Prosthetic and wheelchair management of elderly patients following above the knee amputation--a decision at the acute hospital].

Following above-knee amputation in aged persons, rehabilitative measures have to be initiated already by the acute-care clinic, inter alia because lack of movement fosters physical and mental decline. Energy consumption in walking with an above-knee prosthesis moreover is considerably higher than in the non-amputated. The rehabilitation counsellor is called upon to determine the most promising route in view of an acceptable long-term outcome. Our aim following wound healing is that of early prosthetic provision to enable the old patient to return to his familiar surroundings. Before taking a decision as to prosthetic and/or wheelchair management, numerous parameters must be critically analyzed and appraised. These are dealt with in some detail in the present article. In case of prosthetic management, the model used should reflect current levels, and be supplied in the raw to permit convenient implementation of necessary corrections. General physical as well as gait training are of great significance. Selection of a wheelchair should be a matter of individualized prescription. The above-knee amputee must be viewed from his whole personality, i.e. rehabilitation not only refers to looking after the stump but has to consider the entire person. An essential role is played here by the individual's social environment.

Amputation, Surgical↗

Different patterns of cartilage wear in medial and lateral gonarthrosis.

We studied the morphologic changes of cartilage wear on the resected parts of the joint in 42 knees operated on with a total knee prosthesis. The medial and lateral compartments were divided into 6 equal regions on both the tibial and femoral sides. The amount of cartilage/bone destruction was classified into 4 grades in each region. In medial and lateral arthrosis, maximal wear was found in the middle of the joint, but it was more marked in the lateral group. In the medial group, wear was greater in the anterior regions. In the lateral group, we found more wear in the posterior regions. We ascribed these findings to different anterior/posterior translations of the medial and lateral condyles during flexion/extension of the knee joint.

Aged↗

Thrombosis of axillary-femoral bypass secondary to prosthesis suspension belt.

Patients with peripheral vascular disease and lower extremity amputation frequently undergo arterial bypass surgery to salvage the opposite leg. Compression of axillary-femoral bypass grafts can occur from a variety of causes. The primary physician should monitor graft pulses closely. Compression should be avoided by using forearm crutches instead of axillary crutches. Waist belts for prosthetic support should not be used, and alternatives such as a thigh corset or shoulder suspension should be used. The patient should avoid sleeping on the graft, using a wrist restraint when necessary. If the patient gains weight, garments should be adjusted so as not to be constricting. Upper extremity exercises, particularly in should abduction and extension, should not be so vigorous as to put tension on the graft. A 77-year-old woman with a left below-knee amputation underwent an axillary-femoral bypass for right lower extremity arterial insufficiency which subsequently thrombosed due to compression by the waist belt of her below-knee prosthesis. A series of guidelines are outlined, so that the physiatrist can help maintain graft patency, prolong limb salvage, and avert similar complications in such patients.

Aged↗

Adverse impact of surgical site infections in English hospitals.

Between October 1997 and June 2001, 140 English hospitals participating in the surveillance of surgical site infection (SSI) with the Nosocomial Infection National Surveillance Service (NINSS) reported 2832 SSIs following 67 410 surgical procedures in nine defined categories of surgery. Limb amputation had the highest incidence of SSI with 14.3 SSIs per 100 operations. For all categories of surgery, except knee prosthesis (P=0.128), there was a linear increase in the incidence of SSI when the American National Nosocomial Infections Surveillance risk index increased. Superficial incisional SSI was more common than deep incisional and organ/space SSI, and accounted for more than half of all SSIs for all categories of surgery. The postoperative length of stay (LOS) was longer for patients with SSI, and when adjusted for other factors influencing LOS, the extra LOS due to SSI ranged from 3.3 days for abdominal hysterectomy to 21.0 days for limb amputation, and was at least nine days for the other categories. The additional cost attributable to SSI ranged from pound959 for abdominal hysterectomy to pound6103 for limb amputation. Deep incisional and organ/space SSI combined incurred a greater extra LOS and cost than superficial incisional SSI for all categories of surgery, except limb amputation. The crude mortality rate was higher for patients with SSI for all categories of surgery but, after controlling for confounding, only patients with SSI following hip prosthesis had a mortality rate that was significantly higher than those without SSI [odds ratio (OR)=1.8, P=0.002]. However, the adjusted mortality rate for patients with deep incisional and organ/space SSI compared with those without SSI was significantly higher for vascular surgery (OR=6.8, P<0.001), hip prosthesis (OR=2.5, P=0.005) and large bowel surgery (OR=1.8, P=0.04). This study shows that the adverse impact of SSI differs greatly for different categories of surgery, and highlights the importance of measuring the impact for defined categories rather than for all SSIs and all surgical procedures.

Amputation, Surgical↗

[Antibiotic chemoprophylaxis in orthopedic prosthesis implantation].

In elective orthopedic surgery, as well as in any type of clean operations, it is now advised to administer antibiotic prophylaxis only when extraneous material is implanted (prostheses). Given the most frequent appearance of staphylococcal postoperative infections, in orthopedic surgery the antibiotic used for prophylaxis should be particularly active against these microorganisms. Therefore, the first- (cefazolin) and second-generation (cefuroxime or cefamandole) cephalosporins are usually recommended. Because prosthetic infections are more and more frequently caused by methicillin-resistant staphylococci, the glycopeptides (vancomycin and teicoplanin) are often recommended for prophylaxis and more frequently used in routine practice, at least in hospital environments in which these microorganisms often appear. Indeed, various investigations have demonstrated that a single dose of teicoplanin is equally protective as multiple doses of other antibiotics usually used. Regardless of the type of surgery, perioperative prophylaxis should be administered as an i.v. bolus or as a small infusion. However, for mono- or bilateral knee prosthesis, regional prophylaxis has been suggested in recent years, i.e., antibiotic administration in a vein of the foot or leg being operated. The pharmacokinetic and clinical results of this technique have proved to be quite successful.

Anti-Bacterial Agents↗

Pyoderma gangrenosum occurring in a lower limb fasciocutaneous flap--a lesson to learn.

Pyoderma gangrenosum is a destructive cutaneous disease characterised by progressive painful ulceration. The occurrence of pyoderma gangrenosum at a surgical site is rare (especially if there is no predisposing illness), but is well recognised. We present a case of a 63-year-old man who developed erythematous ulcerative lesions due to pyoderma gangrenosum in and around a lower limb fasciocutaneous flap used to cover an exposed total knee prosthesis. The lesions were initially confused with postoperative wound infection. No predisposing disorder, other than the rarely reported association with osteoarthritis, was found. The diagnosis is important because its rapid detection not only avoids unnecessary treatment but also allows for prompt intervention with oral steroids. This case is presented to alert surgeons to the presence of pyoderma gangrenosum and its diagnostic confusion with postoperative wound infection.

Anti-Inflammatory Agents↗

Bone strains and anterior lift-off, measured with three alternative designs of tibial components of TKA.

Total knee replacement is a successful procedure with high clinical success rates. Problems are mostly initiated on the tibial side, and may be due to - amongst others - improper mechanical design of the tibial base plate. In this paper some new design concepts for the tibial component of a total knee prosthesis are presented. They are evaluated experimentally using a model for a proximal tibia, and strain gauge measurements and displacement measurements as experimental techniques. The designs are meant to yield a physiological load sharing between the trabecular and the cortical bone in the proximal tibia, and to minimize anterior lift-off of the tibial base plate. The optimal design required a metal backing of the plastic part and a thin continuous metallic rim in contact with the proximal tibial cortex. An optimal macro-composite structure within the plastic part was obtained by using thin steel wires in the transversal direction, connected to the metallic rim. With this optimal design, it was shown that the force required to close the anterior gap at simulated knee bending was smaller than 250 N, which can easily be applied clinically by an anteriorly placed clamp or bone screw.

Journal Article↗

Patient satisfaction, function and return to work after knee arthroplasty.

We investigated the working status during 2 years before and 2 years after primary knee prosthetic operation for arthrosis in order to identify preoperative factors predicting patient satisfaction, function and working capacity. 162 patients (86 women) younger than 60 years of age when operated on with a knee prosthesis during 1993 were studied. 91% of the patients returned a Nottingham Health Profile (NHP) questionnaire, and the Social Insurance Office could supply data on all patients. There was a positive association between the duration of pre- and postoperative sick-leave in the patients who returned to work. Preoperative sick-leave longer than 180 days increased the risk of postoperative disability pension, which was not found to be influenced by the grade of the work. Among the 52 patients who returned to work postoperatively, all 6 NHP functional categories were better in the patients with less than 180 days of preoperative sick-leave than in the patients with more than 180 days of preoperative sick-leave. The overall patient satisfaction was greater among patients who went back to work postoperatively. We conclude that long sick-leave before a knee prosthetic operation increases the risk of long postoperative sick-leave and disability pension and impairs the quality of life.

Arthritis↗

Activity sampling in the assessment of patients with total joint arthroplasty.

Quantitative assessment of patient activity is important in evaluating the outcomes of joint prostheses, and such methods are gaining popularity. The single greatest impediment to quantitative activity assessment is patient compliance. How many days of sampling are necessary to provide reliable and accurate estimates of walking activity? The current study analyzes how well sampling for 4 consecutive days of activity compares to assessing activity for 7 or more days with the same pedometer in 131 patients with either a total hip or total knee prosthesis. The mean steps per day obtained throughout the full-length sampling (7-123 days) was strongly correlated to the one obtained from the random consecutive 4-day sample (r2 = 0.94, P < .001) with only 5 outliers. The 4-day activity assessment gave an underestimation of 4.7% (P = .5). The number of outliers increased with fewer days of sampling. Monitoring activity for 4 consecutive days yields a quantitative assessment that is within 5% of a sampling of 7 or more days.

Adult↗

Rehabilitation after total knee replacement via low-bandwidth telemedicine: the patient and therapist experience.

After a total knee replacement, inadequate rehabilitation is associated with poor physical outcomes and a reduced longevity of the knee prosthesis. We have developed a low-bandwidth telemedicine system to enable rehabilitation services to be delivered directly to the home of patients in rural and remote areas. We have examined the experience of clinical physiotherapists and of 31 participants who received treatment via the system. High levels of satisfaction were reported by participants (mean responses > 7 on a 10 cm visual analogue scale). The service was found to be effective, safe and easy to use, and it integrated well into current clinical practice. The study demonstrates the potential for delivering physiotherapy services via low-bandwidth Internet connections.

Arthroplasty, Replacement, Knee↗

Validity of echographic evaluation of cartilage in gonarthrosis. Preliminary report.

We studied an echographic technique by which precise reproducible measurements of articular cartilage thickness of the knee is possible. Two groups of individuals were studied: a group of 18 patients with gonarthrosis and a control group of 10 normal individuals. The group of 18 patients with gonarthrosis was studied by ultrasound (US) before knee prosthesis surgery. The cartilage thickness was measured within the weight-bearing area. US re-evaluation and histological measurements were made on the pathological specimen following the operation. Results of pre- and post-operative US data were compared with histological data. A good correlation between these measurements was found [P(t) > 10%]. In order to have comparative reference values of the articular cartilage within the weight-bearing area of the femoral trochlea a group of 10 control subjects was also studied with US as above. We found that the articular cartilage thickness of the femoral trochlea in the weight-bearing area has a mean of 2.2 +/- 0.3 mm for the lateral condyle and 2.3 +/- 0.2 mm for the medial condyle. The intra-observer and inter-observer difference in measurements was evaluated with Student's t-test. Our data demonstrate that US measurements of articular cartilage thickness of femoral condyles is a sensitive and reproducible technique which permits early diagnosis and management of knee arthropathy as well as quantification of cartilage damage.

Adolescent↗

Fever and autologous blood retransfusion after total knee arthroplasty: a prospective study of 40 autotransfusion events in 21 patients.

The commonest adverse reaction of autotransfusion of drain blood is an increase in temperature, probably due to a cytokine-mediated inflammatory reaction. We recorded body temperature in 21 patients operated on with a total knee prosthesis prospectively during the first 18 postoperative hours. The patients had been given an autotransfusion of autologous filtered drain blood (40 events) within the first 8-9 hours. They all had hypothermia at the end of operation, with a continuous increase in temperature during the first 12 hours whereafter the temperature slowly fell. No additional increase in temperature was seen during the first 2 hours after an autologous retransfusion. Autotransfusion of filtered drain blood within the first 8 postoperative hours after arthroplasty thus did not seem to cause an additional increase in temperature above that due to spontaneous recovery after postoperative hypothermia and surgical trauma.

Aged↗