Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Joint Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48Linked to original sources

Analgesic efficacy and safety comparison of ketorolac tromethamine and Doleron for the alleviation of orthopaedic post-operative pain.

The analgesic efficacy and safety of ketorolac tromethamine (ketorolac), a potent analgesic with anti-inflammatory and antipyretic activities, were evaluated and compared with Doleron, a combination analgesic, in 115 patients with moderate to severe orthopaedic post-operative pain. This was a randomized, double-blind (double-dummy), parallel-group comparison of a single oral dose of one capsule of 10 mg ketorolac with a single oral dose of two Doleron tablets (each tablet contained 150 mg dextropropoxyphene napsylate, 350 mg aspirin and 150 mg phenazone). During the 6 h following treatment, 80% of ketorolac treated patients and 82% of Doleron treated patients experienced adequate pain relief. There were no statistically significant differences in the overall analgesic efficacy between the treatment groups. Three patients (one on ketorolac, two on Doleron) withdrew because of adverse events (vomiting). Nausea (two patients in each treatment group), vertigo (none on ketorolac, three on Doleron) and sore throat (none on ketorolac, two on Doleron) were the only drug-related adverse events reported by more than one person in a treatment group during the trial. A total of 82% of patients given ketorolac and 76% given Doleron experienced no adverse events. A single oral dose of 10 mg ketorolac was shown to be as effective and safe as two Doleron tablets in the treatment of moderate to severe orthopaedic post-operative pain.

Adult↗

Evaluation of three pose estimation algorithms for model-based roentgen stereophotogrammetric analysis.

Model-based roentgen stereophotogrammetric analysis (RSA) uses a three-dimensional surface model of an implant in order to estimate accurately the pose of that implant from a stereo pair of roentgen images. The technique is based on minimization of the difference between the actually projected contour of an implant and the virtually projected contour of a model of that same implant. The advantage of model-based RSA over conventional marker-based RSA is that it is not necessary to attach markers to the implant. In this paper, three pose estimation algorithms for model-based RSA are evaluated. The algorithms were assessed on the basis of their sensitivities to noise in the actual contour, to the amount of drop-outs in the actual contour, to the number of points in the actual contour and to shrinkage or expansion of the actual contour. The algorithms that were studied are the iterative inverse perspective matching (IIPM) algorithm, an algorithm based on minimization of the difference (DIF) between the actual contour and the virtual contour, and an algorithm based on minimization of the non-overlapping area (NOA) between the actual and virtual contour. The results of the simulation and phantom experiments show that the NOA algorithm does not fulfil the high accuracy that is necessary for model-based RSA. The IIPM and DIF algorithms are robust to the different distortions, making model-based RSA a possible replacement for marker-based RSA.

Algorithms↗

Compliant layer acetabular cups: friction testing of a range of materials and designs for a new generation of prosthesis that mimics the natural joint.

Total joint replacements (TJRs) have a limited lifetime, but the introduction of components that exhibit good lubricating properties with low friction and low wear could extend the life of TJRs. A novel acetabular cup design using polyurethane (PU) as a compliant layer (to mimic the natural joint) has been developed. This study describes a series of friction tests that have been used to select the most appropriate material, optimize the design parameters, and fine-tune the manufacturing processes of these joints. To determine accurately the mode of lubrication under which these joints operate, a synthetic lubricant was used in all these tests. Friction tests were carried out to assess the lubrication of four PU bearing materials. Corethane 80A was the preferred material and was subjected to subsequent testing. Friction tests conducted on acetabular cups, manufactured using Corethane 80A articulating against standard, commercially available femoral heads, demonstrated friction factors approaching those for full-fluid-film lubrication with only approximately 1 per cent asperity contact. As the joint produces these low friction factors within less than half a walking cycle after prolonged periods of loading, start-up friction was not considered to be a critical factor. Cups performed well across the full range of femoral head sizes, but a number of samples manufactured with reduced radial clearances performed with higher than expected friction. This was caused by the femoral head being gripped around the equator by the low clearance cup. To avoid this, the cup design was modified by increasing the flare at the rim. In addition to this the radial clearance was increased. As the material is incompressible, a radial clearance of 0.08 mm was too small for a cup diameter of 32 mm. A clearance of between 0.10 and 0.25 mm produced a performance approaching full-fluid-film lubrication. This series of tests acted as a step towards the optimization of the design of these joints, which has now led to an in vivo ovine model.

Acetabulum↗

Mechanics of the knee and problems in reconstructive surgery.

Static force transmission at the knee is analysed using measurements from radiographs showing the position of the line of body weight and also the bones of the knee in their correct orientation during function. With this technique it is possible to suggest values for a variety of forces acting at the knee. During function the degree of knee flexion is not as important as the angle that the thigh makes with the vertical. The tension in the extensor mechanism is not the same above and below the patella. Failure to recognise these two features results in fundamental errors. The patella, the effects of patellectomy and of forward displacement of the attachment of the patellar ligament are discussed. The importance of the transmission of force in the coronal plane is emphasised with particular reference to total knee replacement. It is suggested that small errors of geometry, as seen in the anteroposterior radiograph, can produce large changes of load.

Biomechanical Phenomena↗

Manchester knee arthroplasty.

The results of fifty-one Manchester knee arthroplasties in forty-one patients are reviewed and discussed. Excellent and good results were obtained in 85.4 per cent of arthroplasties. Varus and valgus deformity can be corrected and stability preserved or restored. Complications occurred in only twelve patients but resolved in all except one.

Adult↗

ICLH arthroplasty of the knee: 1968--1977.

The essentially satisfactory results from the ICLH implant as used until 1975 were marred by examples of loosening and sinking of the tibial implant, by patellar pain of varying severity, by wear of the tibial implant caused by fragments of cement and by failure consistently to control the alignment of the leg. This report describes the methods now being used to overcome these complications and gives an account of the success so far achieved.

Arthroplasty↗

Utilisation of shoulder arthroplasty in the UK.

AIMS: To estimate the per capita utilisation of shoulder prostheses in the UK and to compare UK figures to those from the US. METHODS: A postal and telephone survey was undertaken of all hospitals in the UK carrying out orthopaedic operations. The relative usage of total shoulder replacement and hemi-arthroplasty for both elective and trauma indications were analysed and UK figures compared to those from the US. RESULTS: There were 281 replies from 314 questionnaires, a response rate of 90%. The per capita rate of shoulder replacement is approximately one-tenth for total replacement and one-fifth for hemiarthroplasty compared to the US, suggesting that there is an unmet demand in the UK. In the US, the proportion of total replacements to hemi-arthroplasties for elective indications is approximately equal whereas in the UK there are twice as many hemi-arthroplasties, which raises the question as to whether hemi-arthroplasties are being used when a total replacement might be preferable. The numbers of shoulder arthroplasties implanted by individual surgeons and units is, except for a few large centres, small. Consequently, it is much more difficult for the surgeon to evaluate the various prosthetic designs and surgical techniques. CONCLUSION: There is a need for a national register to increase the knowledge about such designs and techniques and to analyse risk factors.

Arthroplasty, Replacement↗

Prophylaxis against deep venous thrombosis after total knee arthroplasty. Pneumatic plantar compression and aspirin compared with aspirin alone.

A prospective, randomized study was conducted to assess the efficacy of pulsatile pneumatic plantar compression for prophylaxis against deep venous thrombosis after total knee arthroplasty performed with use of regional anesthesia. One hundred and twenty-two patients (164 knees) who were scheduled to have a unilateral or a one-stage bilateral total knee arthroplasty were separately randomized to be managed with either aspirin alone or the pulsatile pneumatic plantar-compression device and aspirin. The prevalence of deep venous thrombosis was 27 per cent (twenty-two of eighty-one knees) in the group treated with pneumatic plantar compression compared with 59 per cent (forty-nine of eighty-three knees) in the patients managed with aspirin alone (the control group) (p < 0.001). A significant difference was also noted in the group that had had a unilateral arthroplasty (a prevalence of 27 per cent [eleven of forty-one knees] in the group treated with pneumatic plantar compression, compared with 67 per cent [twenty-six of thirty-nine knees] in that treated with aspirin alone; p < 0.006) and in the group that had had a one-stage bilateral procedure (a prevalence of 28 per cent [eleven of forty knees] in the group treated with pneumatic plantar compression, compared with 52 per cent [twenty-three of forty-four knees] in that treated with aspirin alone; p < 0.03). No proximal thrombi were noted in any patient who used the pulsatile pneumatic plantar-compression device, while the prevalence of proximal thrombosis in the popliteal or femoral veins was 14 per cent (twelve of eighty-three knees) in the group treated with aspirin alone (p < 0.0003). In the group treated with a unilateral procedure and aspirin alone the prevalence of proximal thrombosis was 13 per cent (five of thirty-nine knees; p < 0.02), while in the group treated with a bilateral procedure and aspirin alone it was 16 per cent (seven of forty-four knees; p < 0.01). Only in the patients who had had a unilateral procedure was use of the compression device associated with significantly less edema postoperatively than was use of aspirin alone. The change between the preoperative and postoperative circumferences of the thigh and leg was significantly less (9 +/- 4.1 millimeters [mean and standard deviation] less for the thigh [p < 0.01] and 6 +/- 3.9 millimeters less for the leg [p < 0.049]) with the compression device than with aspirin alone. In addition, there was significantly less mean drainage (98 +/- 61.1 milliliters) in the group treated with a unilateral procedure and pneumatic compression, compared with that treated with a unilateral procedure and aspirin alone (p < 0.041). An internal timer of the compression device was used to assess the compliance of the patient with use of the device, and a relationship between deep venous thrombosis and the total duration of treatment with the device was found. The patients in whom deep venous thrombosis did not develop used the device for a mean of 96 +/- 23.4 hours (range, sixty to 164 hours) postoperatively, or 19.2 +/- 5.1 hours a day, while those in whom thrombosis developed used it for a mean of 67 +/- 21.1 hours (range, twenty-six to 101 hours), or 13.4 +/- 4.3 hours a day (p < 0.001). No untoward effects were noted in any patient who used the device. This study confirms the safety and efficacy of pulsatile pneumatic plantar compression and aspirin compared with aspirin alone and supports the use of mechanical compression for prophylaxis against deep venous thrombosis and for reduction of edema in patients who have had a total knee arthroplasty. In addition, we found a direct relationship between compliance with the use of this device and its efficacy in reducing deep venous thrombosis.

Arthritis, Rheumatoid↗

Radiology of knee joint replacement.

As total knee replacement becomes more successful due to advances in surgery and bioengineering, a greater number of patients will be offered this procedure as a viable alternative to arthrodesis. Radiologic consultation will be sought for evaluation of proper alignment as well as postoperative complications such as loosening, instability, dislocation, limitation of range of motion, fracture, and infection. This evaluation may be accomplished by plain films and arthrography. Radiographic aspects of these features are discussed and illustrated.

Biomechanical Phenomena↗

Multinuclide digital subtraction imaging in symptomatic prosthetic joints.

One hundred eleven patients with symptomatic prosthetic joints (86 hips, 23 knees, and two shoulders) were evaluated for prosthetic loosening and infection by combined technetium-99m-MDP/gallium-67 digital subtraction imaging. Clinical correlation was based on the assessment of loosening and bacterial cultures obtained at the time of surgery in 54 patients, joint aspiration cultures obtained in 37 patients, and long-term clinical follow-up for greater than 1.5 years in an additional 15 patients. Results revealed an 80%-90% predictive value of a positive test for loosening, and a 95% predictive value of a negative test for infection. However, because of the low sensitivities and specificities observed, this approach to the evaluation of symptomatic prosthetic joints does not seem cost effective.

Adult↗

Culture of joint specimens in bacterial arthritis. Impact of blood culture bottle utilization.

The advantage of inoculating blood culture bottles (BCB) with a bulk volume of joint fluid was studied by analyzing results for 155 positive specimens cultured in parallel in BCB and on conventional solid media. The specimens came from both natural and artificial joints of 89 patients treated in 1975-1994. One third of the specimens from patients not on antibiotics and half of the specimens from patients on antibiotics were positive by BCB culture only. Some fastidious or slow-growing organisms were detected exclusively by this method. Additional contaminants were also picked up, but the inconvenience was relatively minor. Alternative procedures for detecting microbes in joint specimens are discussed.

Ankle Joint↗