Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “GASES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48Linked to original sources

Wound metastasis after laparoscopy with different insufflation gases.

BACKGROUND: There is growing evidence that laparoscopy for malignancy is associated with an increased incidence of metastasis to port sites. This study investigated the effect of different insufflation gases on port-site metastasis after laparoscopy in an established animal model. METHODS: Forty-eight Dark Agouti rats with an established adenocarcinoma in the left flank underwent laparoscopic intraperitoneal tumor laceration. The gas used for insufflation was one of the following (12 rats in each group): (1) CO2, (2) N2O, (3) helium, or (4) air. Rats were killed 7 days after the procedure, and the port sites were examined for the presence of tumor metastasis. RESULTS: Tumor involvement of port sites was significantly less likely after helium insufflation than in the other groups (p < 0.0001). There was no significant difference between the air, CO2, and N2O groups. CONCLUSIONS: This study suggests that the development of metastases in port sites after laparoscopy may be influenced in part by the choice of insufflation gas used to create the pneumoperitoneum. In particular, helium was associated with a reduced rate of metastases.

Adenocarcinoma↗

Keeping Mars warm with new super greenhouse gases.

Our selection of new super greenhouse gases to fill a putative "window" in a future Martian atmosphere relies on quantum-mechanical calculations. Our study indicates that if Mars could somehow acquire an Earth-like atmospheric composition and surface pressure, then an Earth-like temperature could be sustained by a mixture of five to seven fluorine compounds. Martian mining requirements for replenishing the fluorine could be comparable to current terrestrial extraction.

Journal Article↗

Viscosity of dilute gases and vapors.

The well-known formula for calculating the viscosity of hard sphere gases, eta(o) = 2(mkT)(1/2)/3pi(3/2)sigma(2), where sigma(2) is molecular cross section, is altered to eta(o) = K(MT)(1/2)/V(t) (2/3), where V(t) is the molal volume of a liquid that has expanded sufficiently to permit mean free paths long enough to have significant fractions of the random thermal momenta of molecules in free flight and M is molal mass.This formulation places upon a single straight line points for all nonpolar molecules, mono- and polyatomic molecules alike, over long ranges of temperature.

Journal Article↗

Nasal dosimetry of inhaled gases and particles: where do inhaled agents go in the nose?

The anatomical structure of the nasal passages differs significantly among species, affecting airflow and the transport of inhaled gases and particles throughout the respiratory tract. Since direct measurement of local nasal dose is often difficult, 3-dimensional, anatomically accurate, computational models of the rat, monkey, and human nasal passages were developed to estimate regional transport and dosimetry of inhaled material. The computational models predicted that during resting breathing, a larger portion of inspired air passed through olfactory-lined regions in the rat than in the monkey or human. The models also predicted that maximum wall mass flux (mass per surface area per time) of inhaled formaldehyde in the nonsquamous epithelium was highest in monkeys (anterior middle turbinate) and similar in rats and humans (dorsal medial meatus in the rat and mid-septum in the human, near the squamous/nonsquamous epithelial boundary in both species). For particles that are 5 microm in aerodynamic diameter, preliminary simulations at minute volume flow rates predicted nasal deposition efficiencies of 92%, 11% and 25% in the rat, monkey, and human, respectively, with more vestibular deposition in the rat than in the monkey or human. Estimates such as these can be used to test hypotheses about mechanisms of toxicity and supply species-specific information for risk assessment, thus reducing uncertainty in extrapolating animal data to humans.

Animals↗

Optical remote measurement of toxic gases.

Enactment of the Clean Air Act Amendments (CAAA) of 1990 has resulted in increased ambient air monitoring needs for industry, some of which may be met efficiently using open-path optical remote sensing techniques. These techniques include Fourier transform spectroscopy, differential optical absorption spectroscopy, laser long-path absorption, differential absorption lidar, and gas cell correlation spectroscopy. With this regulatory impetus, it is an opportune time to consider applying these technologies to the remote and/or path-averaged measurement and monitoring of toxic gases covered by the CAAA. This article reviews the optical remote sensing technology and literature for that application.

Air Pollutants↗

Measurement and analysis of the relationship between ammonia, acid gases, and fine particles in eastern North Carolina.

An annular denuder system, which consisted of a cyclone separator; two diffusion denuders coated with sodium carbonate and citric acid, respectively; and a filter pack consisting of Teflon and nylon filters in series, was used to measure acid gases, ammonia (NH3), and fine particles in the atmosphere from April 1998 to March 1999 in eastern North Carolina (i.e., an NH3-rich environment). The sodium carbonate denuders yielded average acid gas concentrations of 0.23 microg/m3 hydrochloric acid (standard deviation [SD] +/- 0.2 microg/m3); 1.14 microg/m3 nitric acid (SD +/- 0.81 microg/m3), and 1.61 microg/m3 sulfuric acid (SD +/- 1.58 microg/m3). The citric acid denuders yielded an average concentration of 17.89 microg/m3 NH3 (SD +/- 15.03 microg/m3). The filters yielded average fine aerosol concentrations of 1.64 microg/m3 ammonium (NH4+; SD +/- 1.26 microg/m3); 0.26 microg/m3 chloride (SD +/- 0.69 microg/m3), 1.92 microg/m3 nitrate (SD +/- 1.09 microg/m3), and 3.18 microg/m3 sulfate (SO4(2-); SD +/- 3.12 microg/m3). From seasonal variation, the measured particulates (NH4+, SO4(2-), and nitrate) showed larger peak concentrations during summer, suggesting that the gas-to-particle conversion was efficient during summer. The aerosol fraction in this study area indicated the domination of ammonium sulfate particles because of the local abundance of NH3, and the long-range transport of SO4(2-) based on back trajectory analysis. Relative humidity effects on gas-to-particle conversion processes were analyzed by particulate NH4+ concentration originally formed from the neutralization processes with the secondary pollutants in the atmosphere.

Acids↗

Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans from stack gases of electric arc furnaces and secondary aluminum smelters.

This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD]= 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 microg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 microg I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650-750 degrees C) are lower than those for EAFs (1600-1700 degrees C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are approximately 27, 53, and approximately 24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g I-TEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/ yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.

Air Pollutants↗

Predicting extents of mercury oxidation in coal-derived flue gases.

The proposed mercury (Hg) oxidation mechanism consists of a 168-step gas phase mechanism that accounts for interaction among all important flue gas species and a heterogeneous oxidation mechanism on unburned carbon (UBC) particles, similar to established chemistry for dioxin production under comparable conditions. The mechanism was incorporated into a gas cleaning system simulator to predict the proportions of elemental and oxidized Hg species in the flue gases, given relevant coal properties (C/H/O/N/S/Cl/Hg), flue gas composition (O2, H2O, HCl), emissions (NO(X), SO(X), CO), the recovery of fly ash, fly ash loss-on-ignition (LOI), and a thermal history. Predictions are validated without parameter adjustments against datasets from lab-scale and from pilot-scale coal furnaces at 1 and 29 MWt. Collectively, the evaluations cover 16 coals representing ranks from sub-bituminous through high-volatile bituminous, including cases with Cl2 and CaCl2 injection. The predictions are, therefore, validated over virtually the entire domain of Cl-species concentrations and UBC levels of commercial interest. Additional predictions identify the most important operating conditions in the furnace and gas cleaning system, including stoichiometric ratio, NO(X), LOI, and residence time, as well as the most important coal properties, including coal-Cl.

Air Pollutants↗

Pilot-scale study of the effect of selective catalytic reduction catalyst on mercury speciation in Illinois and Powder River Basin coal combustion flue gases.

A study was conducted to investigate the effect of selective catalytic reduction (SCR) catalyst on mercury (Hg) speciation in bituminous and subbituminous coal combustion flue gases. Three different Illinois Basin bituminous coals (from high to low sulfur [S] and chlorine [Cl]) and one Powder River Basin (PRB) subbituminous coal with very low S and very low Cl were tested in a pilot-scale combustor equipped with an SCR reactor for controlling nitrogen oxides (NOx) emissions. The SCR catalyst induced high oxidation of elemental Hg (Hg0), decreasing the percentage of Hg0 at the outlet of the SCR to values <12% for the three Illinois coal tests. The PRB coal test indicated a low oxidation of Hg0 by the SCR catalyst, with the percentage of Hg0 decreasing from approximately 96% at the inlet of the reactor to approximately 80% at the outlet. The low Cl content of the PRB coal and corresponding low level of available flue gas Cl species were believed to be responsible for low SCR Hg oxidation for this coal type. The test results indicated a strong effect of coal type on the extent of Hg oxidation.

Air Pollutants↗

Assessment of the pulmonary toxicity of inhaled gases and particles with physicochemical methods.

Physicochemical techniques used for evaluating the pulmonary surfactant (PS) quality are discussed as methods useful in assessing toxicity of inhaled gases and particles. Two standard devices, Langmuir-Wilhelmy film balance and pulsating bubble apparatus, are presented in detail, and the measured results of interaction between sulfuric acid and 2 models of PS materials are analyzed. The evident decrease in surface activity of the pulmonary surfactant after its contact with the acid at concentrations approaching 0.001 M may be considered as an indicator of the adverse effect, which can result in several health problems. The presented approach can be used as a method of assessing pulmonary toxicity of any substances present in the breathing air.

Air Pollution, Indoor↗

Quantitative evaluation of a novel sensor for measuring muscular tissue flow and gases.

Information about muscular tissue flow is important for diagnosing, treating and monitoring patients with tissue ischemia. For this purpose an objective method which is reproducible and continuous is needed. In co-operation with the company Unisense A/S, we have developed a sensor for instantaneous and continuous monitoring of muscle tissue flow in vivo. The method is based on a flexible microsensor which emits and measures minute amounts of inert tracer gases. The objective was to evaluate the capability of the microsensor to measure varying degrees of tissue flow changes and compare these measurements with the 133Xenon Washout Technique for measuring local perfusion rates in skeletal muscle. The Unisense microsensor was tested in the gracilis muscle of six anaesthetized pigs subjected to varying degrees of muscle ischemia. We found that both tissue flow and pO2 declined in synchrony with reduced blood flow to the lower extremities. All the data from the Unisense microsensor show the same trend as the Xenon data and thus confirms that the microsensor can measure changes in tissue flow.

Animals↗

Isolation and measurement of 15N2 from respiratory gases of animals administered 15N-labeled substances.

A method is described for collection of metabolic 15N2 from in vitro preparations or intact rats administered 15N-containing compounds. The methods enables routine collection and mass spectrometric measurement of as little as 10 mumol 15N2 respired by a rat over a 24-h period. A device is described that includes either an animal chamber or a tissue reaction vessel in a closed recycling atmosphere, with automatic O2 replenishment and removal of CO2 and water. It is capable of sustaining moderate vacuum and is coupled to a high-vacuum manifold designed to process the contained atmosphere and respiratory gases. The starting atmosphere is an 80:20 mix of sulfur hexafluoride and O2. Recovery of 15N2 gas from the system without an animal present was 101.3 +/- 5.75%. When 15N2 gas was very slowly infused iv into an animal, recovery was 89.1 +/- 5.38%. Use of the method in studies of the fate of [15N]hydrazine in rats indicated that about 15% of the administered hydrazine is rapidly converted to 15N2, followed by slower conversion of an additional 7-10% over the next several hours.

Animals↗

Evaluating the toxicity of urban patterns of oxidant gases. I. An automated chronic gaseous animal inhalation exposure facility.

An automated animal inhalation exposure facility was designed to conduct chronic exposures of rodents to gaseous pollutants. The facility consisted of 3 walk-in chambers with modular cages to allow for exposure of up to a maximum of 480 mice or 240 adult rats. Critical parameters of operation, such as relative humidity, pollutant concentration, and temperature, were monitored continuously. Failure of the system to maintain parameters within specified limits activated the alarm system. Distribution of test gases in the chambers was evaluated for homogeneity, and the standard deviation was determined to be within +/- 5% of the target concentrations throughout the chamber. The exposure facility was successfully used to expose 720 rats to diurnal patterns of O3 (baseline of 0.06 ppm for 13 h with an exposure peak to 0.25 ppm over 9 h) and NO2 (baseline of 0.5 ppm for 16 h with an exposure peak to 1.5 ppm over 6 h) for a period of 18 mo.

Administration, Inhalation↗

Evaluation of waste anesthetic gases, monitoring strategies, and correlations between nitrous oxide levels and health symptoms.

The release of waste anesthetic gases (WAG) in hospital operating rooms (ORs) was evaluated to determine if staff exposure to nitrous oxide exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV) and investigate possible correlations between symptoms and nitrous oxide exposure. The monitoring strategy consisted of nitrous oxide measurements by personal monitoring of the anesthetists and scrub nurses, and area monitoring at the exhaust grills. In addition, room ventilation rates and carbon dioxide concentrations were measured. Self-administered questionnaires were given to both the operating room personnel and staff on control wards. Nitrous oxide levels exceeded the current TLV of 50 ppm in 4 of 12 ORs. Anesthetists typically received the highest nitrous oxide exposure. There was a strong correlation (r2 = 0.90) for nitrous oxide dosimetry results between anesthetists and scrub nurses, and a fair correlation (r2 = 0.35) between area monitoring results and the anesthetists' personal exposures. Carbon dioxide levels commonly exceeded 1000 ppm on control wards. A correlation between reported symptoms and nitrous oxide exposure was not demonstrated. Reported symptoms more closely correlated with carbon dioxide levels. Nitrous oxide dosimetry of the anesthetists appears to be the only accurate strategy for monitoring human exposure to WAG in an operating room.

Air Pollutants, Occupational↗

Acid-base regulation in the South American lungfish Lepidosiren paradoxa: effects of prolonged hypercarbia on blood gases and pulmonary ventilation.

The South American lungfish (Lepidosiren paradoxa) has well-developed lungs and highly reduced gills. To evaluate acid-base regulation, we applied hypercarbia while blood gases and pulmonary ventilation were measured for up to 48 h. Dorsal aortic blood was analyzed, and pulmonary ventilation was measured by pneumotachography. Two protocols were used: (1) normocarbia (control) followed by aquatic hypercarbia (7% CO2 approximately 49 mmHg), gas phase normocarbic; and (2) normocarbia (control) followed by combined aquatic/gas phase hypercarbia (7% CO2). Normocarbic values were pHa~7.5, Paco2 approximately 17 mmHg, and [HCO-3]pl approximately 22 mM. For protocol 1, the first hour of exposure increased Paco2 from 17.0 to 37.4 mmHg, and pHa fell to 7.21 and remained there for the rest of the experiment. At 3 h, pulmonary ventilation reached sixfold the normocarbic value but then decreased. For protocol 2, combined gas phase/water hypercarbia had a large effect on acid-base status. Thus, Paco2 increased gradually to 74 mmHg (pHa=7.15) at 48 h. At 3 h, ventilation reached a sixfold increase relative to normocarbic control but then rose further to a 60-fold peak at 6 h, followed by a gradual decline. As in some salamanders and air-breathing teleosts, there was no evidence of active extracellular modulation bicarbonate.

Acid-Base Equilibrium↗

Maternal blood-gases, PAo2--Pao2), hysiological shunt and VD/VT in normal pregnancy.

Serial measurements of maternal blood-gases, alveolar-to-arterial oxygen tension difference (PAO2--PaO), calculated pulmonary venous admixture (physiological shunt), deadspace/tidal volume ratio (VD/VT), and respiratory minute volume have been made in a carefully selected group of normal pregnant patients at 12, 24, 32 and 38 weeks of gestation and 5 weeks after delivery. All measurements were made in the semi-recumbent position with a left lateral pelvic tilt. Mean arterial PO2 was consistently greater than 100 mm Hg throughout pregnancy, although the value decreased from 106.4 mm Hg at 12 weeks of gestation to 101.8 mm Hg at the 38th week. Despite this decrease there was no change in (PAO2--PaO2) VD/VT, or percentage shunt with increasing gestation; nor did these values differ significantly from non-pregnant values in the same patients.

Adult↗

A passive method of disposal of expired anaesthetic gases.

A passive method for the disposal of waste anaesthetic gases is described. The resistance characteristics of the collector valve, the balancing device and the disposal system were studied. It was found that the resistances offered by the conduction channels and the terminal exhaust valve were extremely low. The collector valves were found to be responsible for most of the expiratory resistance. Swabs taken from various components of the system showed that these were contaminated mainly with commensals and non-pathogenic organisms.

Air Pollution↗

Halothane adsorption complicating the use of soda-lime to humidify anaesthetic gases.

If the anaesthetic circle system is arranged to increase the humidity of fresh anaesthetic gases by placing the carbon dioxide absorbent canister between the fresh gas inlet and the patient, drying of the soda-lime can occur. Very dry soda-lime adsorbs significant quantities of halothane. Using fresh soda-lime, effluent halothane concentration reached 50% of the input concentration in 35s, but this time increased to 500 s when dry soda-lime was used. The use of dry soda-lime can result in a slow inhalation induction or in the release of absorbed halothane during a subsequent anaesthetic.

Adsorption↗