Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48Linked to original sources

Amperometric biosensor for hydrogen peroxide based on ferrocene-bovine serum albumin and multiwall carbon nanotube modified ormosil composite.

A novel amperometric biosensor for hydrogen peroxide (H(2)O(2)) was developed by entrapping horseradish peroxidase (HRP) in a new ormosil composite doped with ferrocene monocarboxylic acid-bovine serum albumin conjugate and multiwall carbon nanotubes (MWNTs). The ormosil was prepared using 3-(aminopropyl)triethoxysilane and 2-(3,4 epoxycyclohexyl)-ethyltrimethoxy silane as monomers. The encapsulated conjugate showed excellent electrochemistry and acted as an electron transfer mediator. The presence of MWNTs improved the conductivity of the composite film. This matrix showed a biocompatible microenvironment for retaining the native activity of the entrapped HRP and a very low mass transport barrier to the substrate, which provided a fast amperometric response to H(2)O(2). The proposed H(2)O(2) biosensor exhibited a linear range of 0.02-4.0 mM with a detection limit of 5.0 microM (S/N = 3) and a K(M)(app) value of 2.0 mM. It could be used for flow injection analysis of hydrogen peroxide with a liner range from 0.02 to 4.5 mM, sensitivity of 0.042 microA/mM and analytical time of 20 s per sample. This biosensor possessed good analytical performance and storage stability.

Adsorption↗

Electrosynthesized poly(pyrrole)/poly(2-naphthol) bilayer membrane as an effective anti-interference layer for simultaneous determination of acethylcholine and choline by a dual electrode amperometric biosensor.

Several neural diseases appear related to the neurotransmitter acethylcholine (ACh) and its metabolite choline (Ch) brain levels so that their simultaneous determination is essential. A cross-talk and interference free dual electrode amperometric biosensor for the simultaneous determination of both analytes has been developed. Acetylcholinesterase (AChE) and choline oxidase (ChO) were immobilized by glutaraldehyde co-crosslinking with bovine serum albumin. A very efficient rejection of electroactive interferents has been achieved by a novel electrosynthesized polymeric bilayer membrane composed by overoxidised poly(pyrrole) and poly(2-naphthol) films. Sensitivities towards several electroactive interferents ranged from ca. 0.04% (e.g. ascorbate) to ca. 0.3% (e.g. dopamine) of those relevant to ACh and Ch (11 and 15 microA/microM, respectively). Detection limits (at S/N=3) in flow injection analysis were ca. 100 nM for both ACh and Ch at the ChO-AChE electrode and ca. 40 nM for Ch at the ChO sensor. Biosensor performances appear more than adequate for brain tissue homogenates and cerebrospinal fluids analysis where average levels in the low micromolar range are typically found.

Acetylcholine↗

Highly selective and sensitive determination of dopamine using a Nafion/carbon nanotubes coated poly(3-methylthiophene) modified electrode.

A poly(3-methylthiophene) modified glassy carbon electrode coated with Nafion/single-walled carbon nanotubes film was fabricated and used for highly selective and sensitive determination of dopamine. The hybrid film surface of the modified electrode was characterized by scanning electrochemical microscopy (SECM) and the results indicated that the carbon nanotubes were dispersed uniformly on the conductive polymer. The experimental results suggest that the hybrid film modified electrode combining the advantages of poly(3-methylthiophene), carbon nanotubes with Nafion exhibits dramatic electrocatalytic effect on the oxidation of dopamine (DA) and results in a marked enhancement of the current response. In 0.1M phosphate buffer solution (PBS) of pH 7.0, the differential pulse voltammetric (DPV) peak heights are linear with DA concentration in three intervals, viz. 0.020-0.10 microM, 0.10-1.0 microM and 1.0-6.0 microM, with correlation coefficients of 0.9993, 0.9996 and 0.9993, respectively. The detection limit of 5.0 nM DA could be estimated (S/N=3). Moreover, the interferences of ascorbic acid (AA) and uric acid (UC) are effectively diminished. This hybrid film modified electrode can be applied to the determination of DA contents in dopamine hydrochloride injection and human serum. These attractive features provide a potential application for either in vitro measurement of DA in the presence of excess AA and UA or as detectors in flow injection analysis (FIA) and high performance liquid chromatography (HPLC).

Biosensing Techniques↗

On-line detection of atmospheric formaldehyde by a conductometric biosensor.

Atmospheric formaldehyde (CH(2)O) was detected under continuous flow conditions by an on-line system comprising of a wet scrubber for a continuous transfer of the pollutant to an aqueous solution, a micro-reactor containing immobilized formaldehyde dehydrogenase (FDH) and a conductometric transducer. By this system atmospheric formaldehyde concentrations in the range 0.05-2 ppm were detected with a sensitivity of 20 microS/ppm. In this concentration range the immobilized enzyme oxidized all the sampled formaldehyde molecules to formic acid, avoiding cumbersome calibration procedures. The operational stability of the biosensor was at least 3 months, working continuously 10 h/day at room temperature.

Air Pollutants↗

Electrochemical performance of 8-hydroxy-2'-deoxyguanosine and its detection at poly(3-methylthiophene) modified glassy carbon electrode.

8-Hydroxy-2'-deoxyguanosine (8-OH-dG) has attracted enormous attention in recent years because it has been acknowledged as a typical biomarker of oxidative DNA damage. In this paper, the electrochemical performance of 8-OH-dG at the poly(3-methylthiophene) (P3MT) modified glassy carbon electrode (GCE) was investigated by cyclic voltammetry (CV) and linear sweep voltammetry (LSV). The conducting polymer P3MT can effectively decrease the oxidation peak potential of 8-OH-dG and greatly enhance its peak current. In 0.1 M pH 7.0 phosphate buffer solution (PBS), the anodic peak currents of cyclic voltammograms are linear with the 8-OH-dG concentration in two intervals, viz. 0.700-35.0 microM and 35.0-70.0 microM, with the correlative coefficients of 0.9992 and 0.9995, respectively. The detection limit of 8-OH-dG can be estimated to be 0.100 microM (S/N=3). This modified electrode can be used to detect the amount of 8-OH-dG in human urine. Furthermore, the effects of scan rate, pH, and interference of uric acid (UA) for the voltammetric behavior and detection of 8-OH-dG are also discussed. This proposed modified electrode also shows excellent reproducibility and stability that makes it an ideal candidate for amperometric detection of 8-OH-dG in flow injection analysis (FIA) and high performance liquid chromatography (HPLC).

8-Hydroxy-2'-Deoxyguanosine↗

The use of single walled carbon nanotubes dispersed in a chitosan matrix for preparation of a galactose biosensor.

Chitosan was chosen as a natural polymer for dispersion of single walled carbon nanotubes (SWNT) based on its ability to efficiently solubilize SWNTs to form a stable dispersion. Moreover, chitosan films deposited on a surface of a glassy carbon (GC) electrode are mechanically stable. Further stabilisation of the chitosan film containing SWNT (CHIT-SWNT) was done by chemical crosslinking with glutaraldehyde and free aldehyde groups produced a substrate used for covalent immobilisation of galactose oxidase (GalOD). Different galactose biosensor configurations were tested with optimisation of composition of inner and outer membrane; and enzyme immobilisation procedure, as well. Detection of oxygen uptake by GalOD on CHIT-SWNT layer at -400 mV is robust and, when flow injection analysis (FIA) was applied for assays, a low detection limit (25 microM) and very high assay throughput rate (150 h-1) was achieved. This new galactose biosensor offers highly reliable detection of galactose with R.S.D. well below 2% and it has been successfully applied to assaying galactose in a blood sample with recovery index between 101.2 and 102.7%.

Biosensing Techniques↗

On-chip microdialysis system with flow-through sensing components.

Microdialysis probes have been used for diabetes treatment as continuous monitoring system coupled to a glucose sensor. An on-chip microdialysis system with in-line sensing electrodes is demonstrated. As a first step towards greater biosensor integration with this miniaturized microdialysis system, a stacked system with in-line sensing electrodes was developed. Impedance electrodes sputtered within the microchannels were used to determine fluid electrical resistance from a dialyzed phosphate buffered saline (PBS) solution, which characterizes solution conductivity as a function of PBS concentration. The permeability of the membrane to the salt ions was obtained as 0.246+/-0.028 microm/s (15 nm pores). Subsequently, experiments measuring PBS dialysis in the time-domain at 64.4% recovery were conducted. The PBS concentration of the reservoir was changed in both a step response and sinusoidally with an 800 s period. The subsequently measured impedance indicates that the system is able to continuously track concentration changes in the reservoir with a 210 s system response delay. Most of this delay is due to the dead volume within the tubing between the syringe pumps and the microsystem. In addition, the predicted response was modeled using linear systems theory and matches the experimental measurements (r=0.98). This system is expected to have the proper sensitivity to track physiologically relevant concentration changes of biomolecules such as glucose (which has a physiological maximum change rate of approximately 4 mg/dl min with a periodicity of 1h or greater) with minimal lag time and amplitude reduction.

Electrochemistry↗

Detection and identification of bacteria using antibiotic susceptibility and a multi-array electrochemical sensor with pattern recognition.

This work proposes the use of amperometric signals generated by a 96-well multi-array dissolved oxygen multi-electrode sensor (DOX) coupled with principal component analysis for continuous monitoring, identification and differentiation of bacteria. Two types of differentiation mechanisms were tested: (1) direct monitoring of respiratory activity via oxygen consumption and (2) quantification of the effect of three broad-spectrum antibiotics on bacteria growth and respiration over time. Five species of bacteria were examined including: Escherichia coli, Escherichia adecarboxylata, Comamonas acidovorans, Corynebacterium glutamicum and Staphylococcus epidermidis. The addition of small concentrations of antibiotics to the growth medium alters the oxygen consumption of the cells and a unique fingerprint is created for a specific cell. This fingerprint is shown to evolve over a specific concentration range that is dependant of instrumental constraints of the DOX system. The application of principal component analysis (PCA) to classify the data was also examined. It was shown that bacteria could be classified simply by their oxygen consumption rates over a varying concentration range. Discrimination between species can also be increased by the effects of the antibiotics on the oxygen consumption of varying concentrations of cells. The proposed DOX-PCA system illustrates a generic template that can be tailored to meet specific research goals by the selection of specific cell/antibiotic combinations and concentrations.

Algorithms↗

Making chlorine greener: performance of alternative dechlorination agents in wastewater.

The residual chlorine in chlorine-disinfected and dechlorinated wastewater was characterized using a liquid chromatograph that was switched between reversed-phase separation and flow injection analysis modes, permitting measurement of fractionated and total residual chlorine, respectively. Residuals were detected in the effluent of an operating wastewater treatment plant employing chlorine disinfection and sulfite dechlorination. Despite dechlorination, an estimated total residual chlorine of 3 microM (0.2 ppm as Cl2) was detected in the effluent. To improve dechlorination effectiveness, four alternative agents (ascorbic acid, iron, sulfite plus iodide mediator, thiosulfate) were compared to sulfite on laboratory-chlorinated wastewater. Listed in order of decreasing relative effectiveness, we found: iron metal >> sulfite plus iodide approximately = thiosulfate > sulfite >> ascorbic acid. Only the iron metal column was completely effective at rapidly removing all traces of residual chlorine.

Ascorbic Acid↗

Applicability of Fenton and H2O2/UV reactions in the treatment of tannery wastewaters.

In this paper we evaluated the H2O2/UV and the Fenton's oxidation processes for the treatment of tannery wastewater under different experimental conditions. Efficiencies were judged by the amounts of organic substances degraded or eliminated under these treatment techniques. Daphnia magna and Vibrio fischeri were used to monitor toxicity. Organic compounds contained in the untreated and treated tannery wastewater were determined and identified using substance specific techniques. Gas chromatography-mass spectrometry (GC-MS) in positive electron impact (EI(+)) mode was applied to determine volatile organics. Atmospheric pressure ionization (API) mass (MS) and tandem mass spectrometry (MS-MS) coupled with flow injection analysis (FIA) or liquid chromatography (LC) were used to detect or identify polar organic pollutants. The experimental results indicated that both oxidation processes--H2O2/UV at pH 3 and Fenton at pH 3.5--are able to reduce TOC content by mineralisation of the organic compounds.

Aliivibrio fischeri↗

Improved assay for catechol-O-methyltransferase activity utilizing norepinephrine as an enzymatic substrate and reversed-phase high-performance liquid chromatography with fluorescence detection.

We have previously established a rapid catechol-O-methyltransferase (COMT) assay using norepinephrine (NE) as a natural substrate and flow-injection analysis. In this study, the method is improved for screening of COMT inhibitors or activators using reversed-phase high-performance liquid chromatographic separation with fluorescence detection. The excess substrate, NE, was removed by the addition of borate in the eluent for HPLC to make an ionic complex with NE, which was eluted faster than the enzymatic product, normetanephrine. The method had good precision and accuracy, and was able to assay one sample in 5 min, showing the usability for screening of COMT inhibitors or activators.

Animals↗

Coupling of size-exclusion chromatography to a continuous assay for subtilisin using a fluorescence resonance energy transfer peptide substrate: testing of two standard inhibitors.

Liquid chromatography (LC) was coupled on-line to a homogeneous continuous-flow protease assay using fluorescence resonance energy transfer (FRET) as a readout for the screening of inhibitors of an enzyme (e.g., Subtilisin Carlsberg). The inhibitors aprotinin (a protein of approximately 6500 g/mol) and 4-(2-aminoethyl)benzenesulfonyl fluoride hydrochloride (AEBSF, 240 g/mol) were mixed with other, non-active compounds and separated on a size-exclusion chromatography column. After the separation, the analytes were eluted to the postcolumn reactor unit where the enzyme solution and subsequently the FRET peptide substrate were added; by measuring the fluorescence intensity the degree of inhibition was monitored on-line. As expected, only the two inhibitors caused a change in the FRET response. Detection limits for aprotinin were 5.8 microM in the flow injection analysis (FIA) mode and 12 microM in the on-line LC mode. System validation was performed by determining IC50 values for aprotinin for the FIA mode (19 microM) and the on-line mode (22 microM). These IC50 values were in line with the value determined in batch experiments (25 microM). With this system, chemical information (i.e., chromatographic retention time) and biological information (i.e., enzyme inhibition) can be combined to characterize mixtures.

Aprotinin↗

Selective determination of quinones by high-performance liquid chromatography with on-line post column ultraviolet irradiation and peroxyoxalate chemiluminescence detection.

A new HPLC method was developed for the simultaneous determination of quinones with peroxyoxalate chemiluminescence (PO-CL) detection following on-line UV irradiation. Quinones [i.e., 1,2-naphthoquinone, 1,4-naphthoquinone, 9,10-anthraquinone, 9,10-phenanthrenequinone] were UV irradiated (254 nm, 15 W) to generate hydrogen peroxide and a fluorescent product that were determined via PO-CL detection. Generation of hydrogen peroxide from quinones with on-line UV irradiation was confirmed using flow injection analysis (FIA) system whereby incorporating an enzyme column reactor immobilized with catalase. Moreover, the structure of the produced fluorophore was confirmed using LC-MS, IR, and (1)H NMR. Afterwards, the conditions for UV irradiation and PO-CL detection were optimized. The separation of four quinones by HPLC was accomplished isocratically on an ODS column within 25 min. The detection limits (signal-to-noise ratio=3) were 6.0 pmol/injection for 1,2-naphthoquinone, 4.4 pmol/injection for 1,4-naphthoquinone, 0.2 pmol/injection for 9,10-anthraquinone, and 0.45 pmol/injection for 9,10-phenanthrenequinone.

Chromatography, High Pressure Liquid↗

Rapid determination of short chain carnitines in human plasma by electrospray ionisation-ion trap mass spectrometry using capillary electrophoresis instrument as sampler.

A capillary electrophoresis apparatus was used as sampler for flow injection analysis (FIA) in tandem mass spectrometry of L-carnitine and its acetyl- and propionyl-metabolites in human plasma. The capillary electrophoresis instrument was coupled to the ion trap mass spectrometer by an electrospray ionization coaxial sheath liquid interface. The electrophoresis capillary introduced the sample directly into the source by applying a prolonged sample injection. The use of the capillary electrophoresis apparatus miniaturised the FIA procedure, substantially reducing the quantities of solvents and samples used, and allowed rapid automated sequential analyses. The method was optimised and validated using a dialyzed human plasma matrix. The plasma samples were analysed after a simple, rapid deproteinisation procedure with acetonitrile and diluted 70 times before direct injection into the mass spectrometer for product ion scan MS/MS analysis in positive ionisation. The total analysis time was 5 min, including capillary preconditioning and acquisition time (3 min). The method was sensitive, allowing the determination of L-, L-acetyl- and L-propionyl-carnitines at 140, 14 and 3.6 nM concentrations (injected values) corresponding to lower limit of quantitation values in plasma of 10, 1 and 0.25 microM, respectively. The method was processed for full validation and applied to the analysis of L-carnitine and its short chain derivatives in human plasma samples.

Carnitine↗

Efficiency of nano-electrospray ionization.

The efficiency of nano-electrospray ionization, defined as the flux of ions reaching the detector of a triple-quadrupole mass spectrometer divided by the flux of analyte ions leaving the needle, has been measured in a series of controlled experiments with dodecyltrimethyl ammonium (DDTMA) bromide, myoglobin, Glu- [1]-fibrinopeptide, and gramicidin S. By varying the flow rate from each needle, the optimum efficiency was determined. In general, the efficiency increased as the flow rate decreased. For DDTMA, efficiencies of up to 12% were measured, although efficiencies of approximately 1% were more common. Ion current measurements indicated efficient transfer of ions from the needle through to the detector. Significant needle-to-needle variations in efficiency were encountered and attributed to variations in ion-generation efficiency.

Equipment Design↗

An impulse-driven liquid-droplet deposition interface for combining LC with MALDI MS and MS/MS.

A simple and robust impulse-driven droplet deposition system was developed for off-line liquid chromatography matrix-assisted laser desorption ionization mass spectrometry (LC-MALDI MS). The system uses a solenoid operated with a pulsed voltage power supply to generate impulses that dislodge the hanging droplets from the LC outlet directly to a MALDI plate via a momentum transfer process. There is no contact between the LC outlet and the collection surface. The system is compatible with solvents of varying polarity and viscosity, and accommodates the use of hydrophobic and hydrophilic MALDI matrices. MALDI spots are produced on-line with the separation, and do not require further processing before MS analysis. It is shown that high quality MALDI spectra from 5 fmol of pyro-Glu-fibrinopeptide deposition after LC separation could be obtained using the device, indicating that there was no sample loss in the interface. To demonstrate the analytical performance of the system as a proteome analysis tool, a range of BSA digest concentrations covering about 3 orders of magnitude, from 5 fmol to 1 pmol, were analyzed by LC-MALDI quadrupole time-of-flight MS, yielding 6 and 57% amino acid sequence coverage, respectively. In addition, a complex protein mixture of an E. coli cell extract was tryptically digested and analyzed by LC-MALDI MS, resulting in the detection of a total of 409 unique peptides from 100 fractions of 15-s intervals.

Chromatography, Liquid↗

Identification of the adduct between a 4-Aza-3-ene-1,6-diyne and DNA using electrospray ionization mass spectrometry.

The interactions between a novel enediyne [1-methyl-2-(phenylethynyl)-3-(3-phenylprop-2-ynyl)-3H-benzimidazolium] (1) and various cytosine-containing oligonucleotides were studied using electrospray ionization mass spectrometry (ESI-MS) in a flow injection analysis mode useful for small volumes. This enediyne ligand, developed as a potential alternative to the highly cytotoxic natural enediynes, some of which have been successfully used as anti-tumor agents, has previously been shown to interact with DNA through frank strand scission as well as via the formation of adducts that lead to 2'-deoxycytidine-specific cleavage. Through ESI-MS, the structures of these adducts were examined and a sequence dependence of the 2'-deoxycytidine-specific cleavage was noted. Collisionally activated dissociation of the observed adducts confirmed the strength of the interactions between the enediyne and DNA and supports a direct linkage between the enediyne and the cytosine nucleobase, likely the result of a nucleophilic attack of the phenylethynyl group by the cytosine amine.

Alkynes↗

Automated sample treatment by flow techniques prior to liquid-phase separations.

Sample preparation (SP) is an integral and important part of an analytical process. Lately, SP has been the topic of increased interest in research and development of novel advanced technologies. Major needs in this aspect are miniaturization, automation, and enrichment. Among other methodologies, flow techniques can be conveniently and effectively coupled to liquid-phase separation technologies for on-line sample preparation. This paper reviews the current trends in on-line automated sample preparation by flow-through techniques prior to liquid-phase separations. Strategies and interfaces developed to couple flow techniques with liquid chromatography, capillary electrophoresis, and mass spectrometry are described. Advantages and limitations of the coupling are discussed. The paper also highlights certain selected applications of these coupled systems.

Chromatography, Liquid↗