Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Coliphages”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48Linked to original sources

Reviewing efficacy of alternative water treatment techniques.

This section is designed to provide a brief summary of some of the findings. A good deal of work has been conducted by Mr N. L. Pavey and the team at BSRIA, Bracknell. The BSRIA publications are an excellent source of further information. Ultraviolet radiation: UV radiation of wavelength 254 nm destroys bacteria by a mechanism of damaging nucleic acids by producing thymine dimers which disrupt DNA replication [Gavdy and Gavdy, 1980]. L. pneumophila has been reported as sensitive to UV dosages of 2,500-7,000 uW.s/cm2 [Antopol & Ellner, 1979; Knudson, 1985]. Antopol and Ellner [1979] examined the susceptibility of L. pneumophila to UV dosage. Their results indicated that 50% of the organisms were killed by 380 uWs/cm2 and 90% were killed by 920 uWs/cm2. Kills of 99 and 99.9% were obtained using 1,840 and 2,760 uWs/cm2 respectively. Muraca et al [1987] showed that continuous UV irradiation resulted in a 5 logarithm decrease in waterborne L. pneumophila in a circulating system. Gilpin [1984] reported that in laboratory buffer solutions, exposure to 1 uW of UV radiation per cm2 achieved a 50% kill of L longbeachae in 5 minutes, L. gormanii in 2-30 minutes and L pneumophila in 17 minutes. Exposure times for 99% kills for L. longbeachae, L pneumophila and L. Gormanii were 33, 48 and 63 minutes respectively. The same research worker conducted experiments using a 3 litre circulating water system, connected to a stainless steel housing containing a UV source. The UV lamp output was 7 ergs/mm2 per second per 100 cm at 254 nm. L. pneumophila was killed within 15 seconds, that is within their first pass through the system. Continuous disinfection with UV has the advantages of imparting no taste, odour or harmful chemical by-products and requires minimal operation and maintenance [Muraca et al 1988]. Keevil et al [1989] state that UV irradiation fails to clear systems of biofilm because of poor penetration into microflocs of the micro-organisms. Copper/silver ionisation: A recent study of full scale hot water test rigs incorporating copper-silver ionisation systems has been reported by Pavey, 1996. Copper and silver ions were introduced into the water by electrolysis. One of the principal mechanisms of biocidal action of these ions is thought to be cell penetration. The positively charged copper ions form electrostatic bonds with negatively charged sites on the cell wall. The cell membrane is thus distorted, allowing ingress of silver ions which attack the cell by binding at specific sites to DNA, RNA, respiratory enzymes and cellular protein, causing catastrophic failure of the life support systems of the cell. Silver and copper ion concentrations of 40 and 400 ug/L respectively were effective against planktonic Legionellae in cold water systems and hot water systems containing soft water. In hard water, the ionisation was ineffective due to the inability to control silver ion concentrations. This was caused by scaling of the electrodes and silver ion complexation by the high concentration of dissolved solids. Bosch et al [1993] had earlier extended the application of copper-silver disinfection to human enteric viruses in water, such as adenovirus, rotavirus, hepatitis A virus, and poliovirus. Their work showed that copper and silver ions in the presence of reduced levels of free chlorine did not ensure the total elimination of viral pathogens from water. In the case of an amoeba, Naegleria fowleria [responsible for primary amoebic meningoencephalitis], Cassells et al [1995] have demonstrated that a combination of silver and copper ions were ineffective at inactivating the amoebae at 80 and 800 ug/L respectively. However addition of 1.0 mg/L free chlorine produced a synergistic effect, with superior inactivation relative to either chlorine or silver-copper in isolation. A similar synergy was reported by Yahya et al [1989] in their study of Staphylococcus sp. and Pseudomonas aeruginosa. Yahya et al [1992] also suggested an additive or synergistic effect in the inactivation of coliphage MS-2 and poliovirus. Other techniques: There are a number of other techniques. We have conducted trials of most of these in the control of Legionella sp., but these fall out of the scope of this article, and as such less emphasis has been placed on them here. Ozonation: Ozone [O3] is an oxidising gas, generated electrically from oxygen [O2]. L. pneumophila can be killed at < 1 mg/L of ozone [Edelstien et al 1982]. Muraca et al [1987] found that 1-2 mg/L of continuous ozone over a six hour contact time, produced a 5 logarithm decrease of L. pneumophila. The effectiveness of ozone treatment against a range of bacteria and coliphages has been studied Botzenhart et al [1993]. E. coli was least resistant to ozone, followed by MS 2-coliphage and PhiX 174-coliphage, with L. pneumophila and Bacillus subtilis spores being the most resistant. (ABSTRACT TRUNCATED)

Chlorine Compounds↗

Evaluation of bacteriophages during the treatment of sludge.

The aim of this work was to determine the effect of liming and composting on the fate of three bacteriophages (somatic coliphages, F-RNA phages, Bacteroides fragilis phages) considered as potential indicators of viral contamination. It was shown that the three bacteriophages studied exhibited variable densities in sludge. Somatic coliphages were most abundant (10(4) to 10(5) x 10 g(-1) DM) then F-RNA bacteriophages (10(2) to 10(4) x 10 g(-1) DM) and Bacteroides fragilis phages (10(1) to 10(2) x 10 g(-1) DM). The efficacy of liming was found to be pH dependent but also sludge dependent. The pH allowing 99% elimination of somatic coliphage is close to 9 for solid sludges and close to 13.5 for liquid sludges. For composting, our findings clearly demonstrated that phage inactivation is very clearly temperature-dependent. For temperatures reaching 70 degrees, there is a 5 log reduction in somatic coliphages while for temperature in the 50-55 degrees C range, the drop off is only 2 log. Considering the efficacy of the treatment methods, it is clear that the well-established industrial procedures that reach temperatures in the 60-70 degrees C range totally inactivate all 3 phages tested and present in sludge before composting.

Bacteriophages↗

Flow fingerprinting fecal pollution and suspended solids in stormwater runoff from an urban coastal watershed.

Field studies were conducted to characterize the concentration vs streamflow relationships (or "flow fingerprints") of fecal pollution and suspended solids in stormwater runoff from the Santa Ana River watershed, the largest watershed in southern California. The concentrations of fecal indicator bacteria and F+ coliphages (viruses infecting E. coli) exhibit little-to-no dependence on streamflow rates, whereas the concentrations of total suspended solids (TSS) exhibit a very strong (power-law) dependence on streamflow rates. The different flow fingerprints observed for fecal pollutants, on one hand, and TSS, on the other hand, reflect different sources and transport pathways for these stormwater constituents. The flow-independent nature of fecal indicator bacteria and F+ coliphages is consistent with the idea that these contaminants are ubiquitously present on the surface of the urban landscape and rapidly partition into the surface water as the landscape is wetted by rainfall. The flow-dependent nature of TSS, on the other hand, is usually ascribed to the shear-induced erosion of channel bed sediments and/or the expansion of drainage area contributing to runoff. The apparent ubiquity of fecal indicator bacteria and F+ coliphages, together with the very high storm-loading rates of fecal indicator bacteria and the low detection frequency of human adenovirus and human enterovirus, suggest that fecal pollution in stormwater runoff from the Santa Ana River watershed is primarily of nonhuman waste origin.

California↗

Giardia and Cryptosporidium removal from waste-water by a duckweed (Lemna gibba L.) covered pond.

AIMS: To determine the ability of duckweed ponds used to treat domestic waste-water to remove Giardia and Cryptosporidium. METHODS AND RESULTS: The influent and effluent of a pond covered with duckweed with a 6 day retention time was tested for Giardia cysts, Cryptosporidium oocysts, faecal coliforms and coliphage. Giardia cysts and Cryptosporidium oocysts were reduced by 98 and 89%, respectively, total coliforms by 61%, faecal coliforms by 62% and coliphage by 40%. There was a significant correlation between the removal of Giardia cysts and Cryptospordium oocysts by the pond (P < 0.001). Influent turbidity and parasite removal were also significantly correlated (Cryptosporidium and turbidity, P=0.05; Giardia and turbidity, P=0.01). CONCLUSIONS: The larger organisms (parasites) probably settled to the bottom of the pond, while removal of smaller bacteria and coliphages in the pond was not as effective. SIGNIFICANCE AND IMPACT OF THE STUDY: Duckweed ponds may play an important role in wetland systems for reduction of Giardia and Cryptosporidium.

Animals↗

Lethality and double-strand scissions from 14C decay in the DNA of micro-organisms.

14C-2-thymidine was incorporated into the DNA of E. coli B/r and of coliphage T4. The labelled organisms were stored for several years at -196 degrees C. Both were periodically assayed for loss of viability, and the coliphage also for the appearance of double-strand breaks (DSBs) in DNA. E. coli B/r exhibited a survival curve with a substantial initial shoulder, extrapolation number 5-2 +/- 2-3, and a final exponential portion corresponding to a lethal efficiency per 14C decay per 2-5 X 10(9) daltons of DNA, of 0-009 +/- 0-002. For coliphage T4, our best estimate for the lethal efficiency per 14C decay is 0-03 +/- 0-04, and that for the DNA breakage efficiency is -0-002 +/- 0-004. The large standard errors result from the very small number of 14C decays occurring in each phage. These results suggest that 14C decay in the DNA of micro-organisms does not cause DSBs but does cause potentially lethal damage to the thymine bases in which decay occurs, and that wild-type E. coli can repair a large number of such DNA lesions.

Carbon Radioisotopes↗

Microbial water quality improvement by small scale on-site subsurface wetland treatment.

It has been demonstrated that large constructed wetlands used for domestic wastewater treatment are useful in the reduction of enteric microorganisms. This study evaluated the ability of three small-scale, on-site subsurface wetlands with different vegetation densities to remove total coliforms, fecal coliforms, coliphage, Giardia and Cryptosporidium. These wetlands were found to be equally efficient in the removal of enteric bacteria and coliphage as larger constructed wetlands. Giardia and Cryptosporidium were usually undetectable after passage of the wastewater through the subsurface wetlands. Coliphage removal increased with increasing vegetation density.

Animals↗

Fate of virus in wastewater applied to slow-infiltration land treatment systems.

The removal of seeded coliphage f2 and indigenous enteroviruses from primary and secondary wastewaters applied by spray irrigation to sandy loam and silt loam soils in field test cells was examined. The amount of f2 recovered from 170-cm-deep soil percolate samples taken over a 53-day period never exceeded 0.1% of applied virus levels and was usually below detection limits. Indigenous enterovirus levels in percolate waters also constituted only a small portion of those found in the wastewaters. At 10 days after seeding, f2 virus was present throughout the soil column but tended to accumulate around the soil core middepths. Coliphage f2 disappeared from the soil surface regions at a high rate, and by 53 days very little virus could be detected within the length of the soil columns. Sterilized soil core segments from different depths were studied to determine their virus adsorption capabilities when suspended in either wastewater, test cell percolate water, or distilled water containing divalent cations. The adsorptive capacity of Windsor and Charlton soils for poliovirus 1 and coliphage f2 increased greatly with the soil sample depth until leveling off at the midcore depths. Soil suspended in wastewater had the least virus adsorption capability for all depths studied.

Animals↗

Novel approach for modifying microporous filters for virus concentration from water.

Electronegative microporous filters composed of epoxyfiberglass (Filterite) were treated with cationic polymers to enhance their virus-adsorbing properties. This novel and inexpensive approach to microporous filter modification entails soaking filters in an aqueous solution of a cationic polymer such as polyethyleneimine (PEI) for 2 h at room temperature and then allowing the filters to air dry overnight on absorbent paper towels. PEI-treated filters were evaluated for coliphage (MS2, T2, and phi X174) and enterovirus (poliovirus type 1 and coxsackievirus type B5) adsorption from buffer at pH 3.5 to 9.0 and for indigenous coliphages from unchlorinated secondary effluent at ambient pH. Adsorbed viruses were recovered with 3% beef extract (pH 9). Several other cationic polymers were used to modify epoxyfiberglass filters and were evaluated for their ability to concentrate viruses from water. Zeta potentials of disrupted filter material indicated that electronegative epoxyfiberglass filters were made more electropositive when treated with cationic polymers. In general, epoxyfiberglass filters treated with cationic polymers were found to adsorb a greater percentage of coliphages and enteroviruses than were untreated filters.

Coliphages↗

Potential usefulness of bacteriophages that infect Bacteroides fragilis as model organisms for monitoring virus removal in drinking water treatment plants.

The presence of bacteriophages at different stages in three drinking water treatment plants was evaluated to study the usefulness of phages as model organisms for assessing the efficiency of the processes. The bacteriophages tested were somatic coliphages, F-specific coliphages, and phages infecting Bacteroides fragilis. The presence of enteroviruses and currently used bacterial indicators was also determined. Most bacteriophages were removed during the prechlorination-flocculation-sedimentation step. In these particular treatment plants, which include prechlorination, phages were, in general, more resistant to the treatment processes than present bacterial indicators, with the exception, in some cases, of clostridia. Bacteriophages infecting B. fragilis were found to be more resistant to water treatment than either somatic or F-specific coliphages or even clostridia. Enteric viruses were found only in untreated water in low numbers, and consequently, the efficiency of the plants in the removal of viruses could not be evaluated with precision. The numbers and frequencies of detection of the various microorganisms in water samples taken in the distribution network served by the three plants confirm the results found in the finished water at the plants.

Bacteriophages↗

Detection of viral pathogens by reverse transcriptase PCR and of microbial indicators by standard methods in the canals of the Florida Keys.

In order to assess the microbial water quality in canal waters throughout the Florida Keys, a survey was conducted to determine the concentration of microbial fecal indicators and the presence of human pathogenic microorganisms. A total of 19 sites, including 17 canal sites and 2 nearshore water sites, were assayed for total coliforms, fecal coliforms, Escherichia coli, Clostridium perfringens, enterococci, coliphages, F-specific (F(+)) RNA coliphages, Giardia lamblia, Cryptosporidium parvum, and human enteric viruses (polioviruses, coxsackie A and B viruses, echoviruses, hepatitis A viruses, Norwalk viruses, and small round-structured viruses). Numbers of coliforms ranged from <1 to 1, 410, E. coli organisms from <1 to 130, Clostridium spp. from <1 to 520, and enterococci from <1 to 800 CFU/100 ml of sample. Two sites were positive for coliphages, but no F(+) phages were identified. The sites were ranked according to microbial water quality and compared to various water quality standards and guidelines. Seventy-nine percent of the sites were positive for the presence of enteroviruses by reverse transcriptase PCR (polioviruses, coxsackie A and B viruses, and echoviruses). Sixty-three percent of the sites were positive for the presence of hepatitis A viruses. Ten percent of the sites were positive for the presence of Norwalk viruses. Ninety-five percent of the sites were positive for at least one of the virus groups. These results indicate that the canals and nearshore waters throughout the Florida Keys are being impacted by human fecal material carrying human enteric viruses through current wastewater treatment strategies such as septic tanks. Exposure to canal waters through recreation and work may be contributing to human health risks.

Clostridium↗

Leaching of phage from Class B biosolids and potential transport through soil.

The objective of this study was to investigate leaching and transport of viruses, specifically those of an indigenous coliphage host specific to Escherichia coli ATTC 15597 (i.e., MS-2), from a biosolid-soil matrix. Serial extractions of 2% and 7% (solids) class B biosolid matrices were performed to determine the number of phage present in the biosolids and to evaluate their general leaching potential. Significant concentrations of coliphage were removed from the biosolids for each sequential extraction, indicating that many phage remained associated with the solid phase. The fact that phage was associated with or attached to solid particles appeared to influence the potential for release and subsequent transport of phage under saturated-flow conditions, which was examined in a series of column experiments. The results indicated that less than 8% of the indigenous coliphage initially present in the biosolids leached out of the biosolid-soil matrix. A fraction of this was subsequently transported through the sandy porous medium with minimal retention. The minimal retention observed for the indigenous phage, once released from the biosolids, was consistent with the results of control experiments conducted to examine MS-2 transport through the porous medium.

Coliphages↗

Rapid determination of the presence of enteric bacteria in water.

A rapid and sensitive method is described for the detection of bacteria in water and various other natural substrates by the isolation of specific bacteriophage. By the addition of large numbers of the organism in question to the sample, the presence of virulent bacteriophage can be demonstrated in as little as 6 to 8 h. Fecal coliform, total coliform, and total coliphage counts were determined for over 150 water samples from several geographical areas over a period of 2 years. Computer analysis of the data shows a high degree of correlation between fecal coliforms and the coliphage present in the samples. With a high correlation coefficient between fecal coliform and coliphage counts, predictions of the fecal coliforms may be made by enumeration of the phage.

Bacteriological Techniques↗

Secondary structure of RNA from bacteriophages f2 Qbeta, and PP7.

Electron microscopy of RNA-protein monolayers prepared under partial denaturing conditions has been used to compare the secondary structure of coliphage f2 and Qbeta and Pseudomonas aeruginosa phage PP7 RNAs. The secondary structure map of f2 RNA contains a central open loop and four symmetrically placed hairpins, which is similar to the pattern reported by Jacobson (A. B. Jacobson, Proc. Natl. Acad. Sci. U.S.A. 73:307-311, 1976) for the closely related phage MS2. With the same denaturing conditions, Qbeta RNA, which is 20% larger than f2 or PP7 RNA, has a central open loop and a smaller terminal loop. PP7 RNA has two large, closed secondary structures, one of which is nearly central. The base composition of PP7 RNA was determined and is similar to that of the group I coliphage RNAs. Thus, the greater amount of large base-paired structure is not related to an increased guanine-plus-cytosine content of PP7 RNA. With increased denaturing conditions, the central, closed structure of PP7 RNA is converted into an open loop. The central structures of all three phages include about 700 nucleotides. The relevance of these findings to the genetic maps of the coliphage RNAs is discussed.

Bacteriophages↗

Lysogenic conversion in Klebsiella pneumoniae: system which requires active immunity regulation for expression of the conversion phenomenon.

We have previously described Klebsiella pneumoniae MirM7b, which, although stably lysogenic for the inducible and nondefective phages FR2 and AP3, is not immune to superinfection by these same viruses. MirA12b, a strain which is lysogenic for FR2 and AP3 and immune to superinfection, has been derived from MirM7b. The sensitivity of this strain and that of the nonimmune parent to several bacteriophages have been compared in this work. It has been found that, whereas MirM7b is sensitive to coliphages P1, T3, T7, and phiI, MirA12b is fully resistant to all of them. It is shown that phages FR2 and AP3 convert Klebsiella strains to resistance to coliphage P1 and coliphages T3, T7, and phiI, respectively, and cause loss of surface antigens in lysogenic cells. To determine such a conversion, both FR2 and AP3 require expression of immunity to superinfection. This explains the differences that exist between MirM7b and MirA12b in both phage sensitivity and surface antigens. Hypotheses are presented to explain the peculiar need for an active superinfection repressor to express lysogenic conversion.

Antigens, Bacterial↗

Microbiological aspects of an urban river used for unrestricted irrigation in the semi-arid region of north-east Brazil.

This study compared the behaviour of pathogenic bacteria (Salmonella and Listeria), faecal indicators (faecal coliforms FC and faecal streptococci FS), somatic coliphages and F-specific bacteriophages in an urban river contaminated with domestic sewage and surface run-off from agricultural and cattle grazing lands. The influence of physical and chemical parameters was also investigated as well as Salmonella and Listeria serotype diversity and drug resistance patterns. Faecal contamination was high (FC = 5 x 10(6) - 4 x 10(3) CFU/100 mL; FS = 4 x 10(5) - 2 x 10(2) CFU/100 mL) but decreased along the river by up to 99.5% following 47% reduction of BOD5 and 91% increase of DO, both associated with the self purification process. Somatic coliphages (6.9 x 10(5) - 1 x 10(3) PFU/100 mL) and F-specific bacteriophages (5.8 x 10(4) - 65 PFU/100 mL) behaved similarly with reductions of 99.85%. Salmonella and Listeria were isolated at all sampling points with highestfrequencies (91-100%) at those with sewage discharge and rural water run-off. The lowest value (35%) occurred at the end of the river where it was (a) wider and shallower, (b) it ran slower and was warmer (29-33 degrees C), (c) the pH was alkaline (8.2-9.9), (d) electrical conductivity (2,200-5,800 microS/cm) and DO (6-13 mg/L) were highest. Pathogen decline did not follow exactly FC and FS reduction patterns, while physical and chemical parameters apparently did not interfere with Salmonella and Listeria survival to the same extent as they did with FC and FS. Somatic coliphages and F-specific bacteriophages did not show more resistance than bacterial indicators. Catchment area contribution seemed to be more significant for pathogens than for indicators and rainy periods increased pathogenic isolation frequency. Five Salmonella serotypes and five serogroups were identified. S. hadar and serogroup E were predominant (50%); both are increasing in Brazil apparently from animal sources. Nearly 25% of Salmonella strains were resistant to at least one of twelve antimicrobials tested. Resistance to tetracycline was common (17%) followed by cefalotine (3%). Five Listeria serogroups were isolated and L. grayi (43%) and L. monocytogenes (9%) were present at all points. Listeria drug resistance rates were 100% for oxaciline followed by clindamicine (97%), tetracycline (34%) and vancomycin (32%). Both pathogenic bacterial strains presented resistance to the same drugs observed in humans and warm blood animals but the high number of sensitive strains and the low numbers of strains resistant to more than one drug was not expected because of the heavy anthropogenic impact in this basin.

Agriculture↗

Use of reflectors to enhance the synergistic effects of solar heating and solar wavelengths to disinfect drinking water sources.

Aluminum reflectors were added to solar units designed to inactivate faecal microorganisms (faecal coliform, E. coli, enterococci, FRNA coliphage, C. perfringens) in stream water and diluted sewage by the two mechanisms (solar heat, solar UV) known to inactivate microorganisms. During sunny conditions, solar units with and without reflectors inactivated E. coli to <1 CFU/100 ml to meet drinking water standards. Solar units with reflectors disinfected the water sooner by increasing the water temperature by 8-10 degrees C to 64-75 degrees C. However, FRNA coliphages were still detected in these samples, indicating that this treatment may not inactivate pathogenic human enteric viruses. During cloudy conditions, reflectors only increased the water temperature by 3-4 degrees C to a maximum of 43-49 degrees C and E. coli was not completely inactivated. Under sunny and cloudy conditions, the UV wavelengths of sunlight worked synergistically with increasing water temperatures and were able to disinfect microorganisms at temperatures (45-56 degrees C), which were not effective in inactivating microorganisms. Relative resistance to the solar disinfecting effects were C. perfringens > FRNA coliphages > enterococci > E. coli > faecal coliform.

Aluminum↗

Evaluation of MBR effluent characteristics for reuse purposes.

One of the advantages of MBR is its excellent effluent quality, which is suitable for a wide range of reuse purposes. We investigated the characteristics of MBR effluent and evaluated them based on the Japanese guideline for the reuse of treated wastewater. As the result, MBR effluent showed qualitative coaracteristics that satisfy the requirement except chromaticity for recreational purpose. Further treatment, such as by oxone or activated carbon, will be required to remove the remaining color. MBR shows high removal efficiency of bacteria and other hazardous microorganisms such as Cryptosporidium. We investigated the removal efficiency of virus by MBR using coliphage as an alternative index. The results showed that high removal efficiency for coliphage could be obtained by MBR. The removal mechanism appears to be that coliphage are attached to the activated sludge and thus rejected by the membrane together with activated sludge particles. With regard to the endocrine disrupters, no significant differences were observed between MBR and CAS in the removal of main endocrine disrupters.

Animals↗

[Phage count in the waters of the Canal Imperial de Aragón and the Ebro River in Saragossa].

Saragossa city supply channel and the river Ebro (up and downstream urban sewage) were studied for the presence of coliphages and B. fragilis phages and their relationship with the bacterian faecal indicators. In the supply channel the coliphages geometric mean was of 130 ufp/100 ml, and showed no correlation with faecal and total coliforms, but it showed indirect correlation with ambient temperature. In the river Ebro the coliphages geometric mean ranged from 290 to 8,000 ufp/100 ml; the relationship with total and faecal coliforms and faecal streptococci was high, but they were temperature independent. With the methodology utilized B. fragilis phages only were recovered in samples with faecal coliforms levels > 1 x 10(4) ufc/100 ml.

Bacillus↗