Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48Linked to original sources

Microfluidic chip with electrochemiluminescence detection using 2-(2-aminoethyl)-1-methylpyrrolidine labeling.

A tertiary amine derivative, 2-(2-aminoethyl)-1-methylpyrrolidine (AEMP) was successfully developed as electrochemiluminescence (ECL) probe within microfluidic chip using ECL detection in this paper. The system was characterized by the interaction between biotin and avidin. In principle, tertiary amine derivatives containing active group can be used as a potential alternative of traditional tris(2,2'-bipyridine)ruthenium(II) [Ru(bpy)3(2+)] label. Firstly, The ECL efficiency of AEMP was characterized via comparing with that of two coreactants enhancing Ru(bpy)3(2+) ECL, TPA and proline. At same condition, AEMP has a similar ECL efficiency to TPA, and much higher than proline. After AEMP reacted with NHS-LC-biotin (succinimidyl-6-(biotinamido) hexanoate), the products and their ECL were analyzed by directly injecting it in the microfluidic chip. A 4.5 cm microchannel was used to separate the mixture of AEMP and biotinylated AEMP. The present works indicated that AEMP has a good reactivity to the analytes containing carboxyl group with a similar ECL efficiency to TPA. Under optimal condition, the detection limits (based on 3 S/N) of AEMP was 2.7 microM. The system was also validated by the reaction between biotin and avidin. The calculated binding ratio between avidin and biotin based on the present method was 4.4.

Aminocaproates↗

Development and characterization of on-chip biopolymer membranes.

In lab-on-a-chip applications, filtration is currently performed prior to sample loading or through pre-cast membranes adhered to the substrate. These membranes cannot be patterned to micrometer resolution, and their adhesion may be incompatible with the fabrication process or may introduce contaminants. We have developed an on-chip separation process using a biocompatible polymer that can be patterned and has controllable molecular rejection properties. We spun cast cellulose acetate (CA) membranes directly onto silicon wafers. Characterization of the molecular flux across the membrane showed that molecular weight and charge are major factors contributing to the membranes' rejection characteristics. Altering casting conditions such as polymer concentration in the casting solution and the quenching-bath composition and/or temperature allowed control of the molecular weight cut-off (MWCO). Three MWCOs; 300, 350, and 700 Da have been achieved for non-linear molecules. Molecular shape is also very important as much higher molecular weight single-stranded DNA was electrophoresed across the membranes while heme with a similar negative charge density was rejected. This was due to DNA's small molecular cross section. This is an important result because heme inhibits polymerase chain reactions (PCR) reducing the detection and characterization of DNA from blood samples.

Base Sequence↗

On-chip micellar electrokinetic chromatographic separation of phenolic chemicals in waters.

This paper describes on-chip micellar electrokinetic chromatography (MEKC) separation of bisphenol A and 3 kinds of alkylphenols, which have been recently recognized as endocrine disrupting chemicals for fish by the Japanese government, using microchip capillary electrophoresis with UV detection. We successfully obtained high-speed separation of the phenolic chemicals within 15 s as optimizing in microfluidic controls and MEKC separation conditions. We obtained fairly good linearity with correlation coefficient of over 0.98 from 0 to 50 mg/l phenolic chemicals except for 4-nonylphenol, which sample is the mixture of many geometrical isomers (r = 0.86). The values of the relative standard deviation for peak height in 50 mg/l phenolic chemicals were less than 8% except for bisphenol A (11.0%). The limits of detection obtained at a signal-to-noise ratio of 3 were from 5.6 to 20.0 mg/l. To realize on-site monitoring, we described strategy for on-chip MEKC analysis of the phenolic chemicals in waters using a portable analyzer based on microfluidic devices.

Chromatography, Micellar Electrokinetic Capillary↗

Analysis of nerve agents using capillary electrophoresis and laboratory-on-a-chip technology.

The nerve agents belong among the most toxic compounds produced by human kind. While they have been used very sporadically until now, typically in local conflicts or by local terrorists groups, the global increase in terrorist activity in the recent years has generated tremendous demand for innovative tools capable of detecting nerve agents. Fast, sensitive and reliable detection of nerve agents in the field is very important issue in present days. Capillary electrophoresis (CE) offers great possibilities for sensitive detection of these harmful compounds as well as incorporation in mobile laboratory and it proved to have capability to detect nerve agent breakdown products in real environmental samples. Laboratory-on-a-chip format offers great possibilities to create portable, field deployable, rapidly responding and potentially disposable device, allowing security forces to make the important decision regarding the safety of civilians. This article overviews the conventional capillary electrophoretic and laboratory-on-a-chip techniques for analysis of degradation products of G-type and V-type nerve agents. It discusses diverse strategies of detection of different nerve agents breakdown products, which are corresponding to their parental nerve agents. It also overviews possibilities and challenges for analysis of the real samples.

Chemical Warfare Agents↗

Lab-on-a-chip technology for determination of protein isoform profiles.

A novel lab-on-a-chip technique for rapid (<15 min) and quantitative isoform-profile determination is presented. Ion-exchange chromatographic separation of protein-isoforms and a sensitive immunoassay detection are combined in a porous monolith chip. Thin lines of immobilized antibodies are used for specific capturing of target molecules, which can be detected by the reaction with antibodies bound to carbon black nano-strings. The bound carbon black is quantified by the use of an image scanner. As demonstrated with transferrin isoforms, differing only by 0.1 pH unit in their pI, this technology can distinguish minor differences in protein carbohydrate structure and enable specific determination of proteins in a complex environment, requiring only a few picogram of isoform for detection.

Chromatography, Ion Exchange↗

Intracellular labeling method for chip-based capillary electrophoresis fluorimetric single cell analysis using liposomes.

An intracellular derivatization method mediated by liposome was developed for single cell analysis with chip-based capillary electrophoresis (CE) and laser-induced fluorescence (LIF) detection. Liposomes with an average diameter of 100 nm were produced from phosphatidylcholine to encapsulate fluorescent dyes by an ultrasonic method. The encapsulation yield and the vesicle density were determined to be 46+/-5% and 8.8 x 10(14)/mL, respectively. The amount of fluorescent dye that entered the cells was dependent on the duration of incubating cells with liposomes, liposome density, and concentration of the dye solution encapsulated in liposomes. The described method introduced cell membrane nonpermeable fluorescent dyes into living cells without reducing cell viability. Single cell analysis using microfluidic chip-based CE revealed that liposome-membrane fusion occurred after entrance of liposomes into the cells, with release of encapsulated fluorescence dyes and labeling of intracellular species.

Cells↗

Most scaphoid non-unions heal with bone chip grafting and Kirschner-wire fixation. Thirty-nine patients reviewed 10 years after operation.

BACKGROUND: Many recommend to operate scaphoid pseudarthroses with wedge grafts and screw fixation. These are difficult operations. We have employed a simpler procedure and wished to review our results with regard to healing and long-term clinical results. PATIENTS AND METHODS: We reviewed 39 unselected scaphoid pseudarthroses which had been operated with Kirschner-wire fixation and bone chip transplantation 10 (3.5-12) years previously. Postoperative cast treatment was 15 (11-30) weeks. RESULTS: Four pseudarthroses failed to unite, one of which was after a trans-scaphoid perilunar dislocation. In another the pins were dislocated by an injury while the arm was in plaster. There were no other complications. All 14 proximal pseudarthroses united. There was no loss of grip strength but some loss of key-pinch strength and wrist mobility. Most patients reported no or little pain and none used analgesics because of wrist pain. The disability of the arm, shoulder and hand (DASH) score was 2 (0-33). Very few cases of mild arthrosis had arisen after operation. Three patients would not have consented to operation if they had known the outcome in advance. CONCLUSIONS: Kirschner-wire fixation and bone chip grafting of scaphoid pseudarthroses is an undemanding operation with few complications that produces good long-term results. Results are excellent also for proximal pole pseudarthroses.

Adolescent↗

Automated nanospray using chip-based emitters for the quantitative analysis of pharmaceutical compounds.

An automated nanospray system based on chip technology (the NanoMate) was successfully interfaced to a modified Particle Discriminator Interface on a triple quadrupole mass spectrometer. A number of the interface parameters were optimized to improve the sampling efficiency for ions from the chip-based system. Analytical performance was assessed using a number of biochemicals as well as via a methodology for a pharmaceutical that passed validation as required by Good Laboratory Practices. Infusion analyses in flow rates <1 microL/min provided advantages in terms of throughput and sample consumption when compared to other methodologies based on liquid chromatography.

Deoxycytidine↗

A microfluidic fluorous solid-phase extraction chip for purification of amino acids.

An electrokinetically-driven microfluidic chip was developed to realize beads-based solid-phase extraction (SPE) of amino acids. This chip uses a two-level (deep/shallow) poly(dimethylsiloxane) (PDMS) microchannel network to confine the fluorous reversed-phase silica beads within the SPE chamber. The mixture of fluorous tagged and non-tagged amino acids was carried into the fluorous solid-phase extraction (F-SPE) chamber by electrokinetic pumping and was successfully separated and extracted. By adding a reference material to the sample, the extraction efficiency of the eluted fluorous-tagged amino acid was calculated using the detection results from mass spectrometry (MS). The F-SPE microchips showed good reproducibility and efficiency, yielding an average extraction efficiency of 55% with a RSD of 10.6% under the typical experimental conditions.

Amino Acids↗

A microchip electrophoresis device with on-line microdialysis sampling and on-chip sample derivatization by naphthalene 2,3-dicarboxaldehyde/2-mercaptoethanol for amino acid and peptide analysis.

The integration of rapid on-chip sample derivatization employing naphthalene 2,3-dicarboxaldehyde and 2-mercaptoethanol (NDA/2ME) with an easily assembled microdialysis/microchip electrophoresis device was carried out. The microchip device consisted of a glass layer with etched microfluidic channels that was sealed with a layer of poly(dimethylsiloxane) (PDMS) via plasma oxidation. This simple sealing procedure alleviated the need for glass thermal bonding and allowed the device to be re-sealed in the event of blockages within the channels. The device was used for analysis of a mixture of amino acids and peptides derivatized on-chip with NDA/2ME for laser-induced fluorescence (LIF) detection. A 0.6 mM NDA/1.2 mM 2ME mixture was simply added into the buffer reservoir for dynamic on-column derivatization of sample mixtures introduced at a flow rate of 1.0 microl/min. Using this scheme, sample injection plugs were derivatized and separated simultaneously. Injections of ca. 12 fmol of 5 mM amino acid and peptide samples were conducted using the system. Finally, a three-component mixture of Arg, Gly-Pro, and Asp was sampled from a vial using microdialysis, derivatized, separated and detected with the system. The ultimate goal of this effort is the creation of a micro-total analysis system for high-temporal resolution monitoring of primary amines in biological systems.

Amino Acids↗

Analytical performance of and real sample analysis with an HBV gene visual detection chip.

A novel hepatitis B virus (HBV) gene detection chip has been developed. The HBV-specific probes immobilized on glass slides were hybridized with polymerase chain reaction (PCR) products of different serum samples. The hybridization signal can be easily visualized upon a sandwich assay with nanoparticle amplification. The analytical performance (e.g., specificity, sensitivity, and accuracy) of this method has been evaluated. The chip-based detection method possesses a greater sensitivity and a better reproducibility than some of the conventional immunological or molecular biological methods (e.g., enzyme-linked immunosorbent assay, ELISA) and is simple, cost-effective, and highly selective.

DNA, Viral↗

Rapid and simple detection of food poisoning bacteria by bead assay with a microfluidic chip-based system.

A rapid bead assay for detecting pathogenic bacteria with a simple microfluidic chip-based system was developed. Five oligonucleotide probes corresponding to the 16S rRNA of the targeted bacteria were coupled covalently to fluorescent beads. Four species of bacteria (Escherichia coli, Salmonella enterica subsp. enterica serovar Enteritidis, Yersinia enterocolitica, and Bacillus cereus) were used as representative food-borne pathogenic bacteria. The RNAs extracted from pure cultures of these microorganisms were fluorescently labeled and hybridized to the oligonucleotide probes-immobilized fluorescent beads (Bead assay). The duplexes of RNAs and the probes-immobilized beads were analyzed with the commercially available microfluidic chip-based system. This bead assay provided results within 3 h following RNA extraction from bacterial cells.

Bacillus cereus↗

Brain CHIP: removing the culprits in neurodegenerative disease.

A factor that is common to the most-frequent neurodegenerative diseases is the accumulation of abnormal proteins that are associated with cellular dysfunction. Contrary to years of speculation, recent evidence suggests that soluble intermediates--not the visible pathological aggregates associated with disease--are the cause of neurotoxicity. These findings suggest that aggregate formation might be an adaptive stress response that is facilitated by neuronal protein triage molecules. In particular, the molecular co-chaperone CHIP (C terminus of HSC70-interacting protein) has been linked to several of these disorders, serving as a crucial catalyst for the ubiquitination of several heat shock protein (HSP)70 client proteins that are involved in neurodegenerative disease. Therefore, understanding the mechanisms that are involved in CHIP-mediated protein trafficking might provide invaluable clues to neuronal function, both in normal and diseased conditions.

Age Factors↗

On-chip transfection of PC12 cells based on the rational understanding of the role of ECM molecules: efficient, non-viral transfection of PC12 cells using collagen IV.

Transfection microarrays (TMA) are important emerging tools for the study of genetic events in living cells in a high-throughput fashion and with significant material economy. However, the difficulty to transfect various relevant cell types on-chip hinders the use of TMAs. Herein we present the realization of a transfection microarray applicable to PC12 cells that heavily relies on the use of ECM molecules. Collagen IV and at a lesser extent laminin or collagen I, but not fibronectin or poly-l-lysine were found to significantly increase the solution-phase as well as on-chip transfection efficiency of PC12 cells. The highest transfection efficiency obtained was consistently above 60%. The observed correlations between the transfection efficiencies and the differential adhesion-induced events triggered by the studied ECMs provides the basis for the rationalization of the role of ECMs on the transfection process.

Animals↗

Development of the "Cell Chip": a new in vitro alternative technique for immunotoxicity testing.

Predictive testing of immunotoxicity associated with chemical compounds is complicated and cannot be accomplished with a single test. As most of the existing tests for immunotoxicity employ experimental animals, there is an increasing need for alternative tests in vitro. We have developed a new system for in vitro immunotoxicity testing, which employs changes in cytokine expression observed in vitro as an endpoint indicating potential for perturbation of the immune system in vivo. This system named "fluorescent cell chip" (FCC) is based on a number of genetically modified cell lines that regulate the expression of a transgene coding for fluorescent protein enhanced green fluorescent protein (EGFP) in a similar way as they regulate expression of IL-1beta, IL-2, IL-4, IFN-gamma, IL-10, TNF-alpha, and beta-actin. Morphological and functional features of selected cell lines expressing EGFP under the control of cytokine promotors were compared with maternal cell lines and this comparison showed that critical functional features of the maternal cell lines were preserved in EGFP expressing cells. Two chemicals with known immunotoxic activities, cyclosporine A and potassium tetrachloro-platinate(II), mediated compound-specific pattern of inhibition and activation of reporter gene expression. Thus, the "fluorescent cell chip" has demonstrated potential for application as a predictive screening test for immunomodulatory activities of chemicals. The major advantage of this approach is the possibility to apply this test in high throughput screening of high number of compounds for their well defined biological activity.

Animals↗

High-resolution analysis of chromosomal imbalances using the Affymetrix 10K SNP genotyping chip.

Array-based comparative genome hybridization is a powerful tool for detecting chromosomal imbalances at high resolution. However, the design and setup of such arrays are time consuming and expensive and thus worthwhile only when large numbers of arrays will be processed. To provide a feasible solution, we have developed an algorithm that renders the publicly available Affymetrix 10K SNP genotyping chip useful for high-resolution analysis of chromosomal imbalances. We have used our newly developed algorithm to analyze data from Affymetrix 10K chips that were hybridized with DNA probes from a variety of different sources, such as primary tumors, cell lines, and blood from patients with unbalanced translocations. In summary, we were able to (i) demonstrate the capability of our method by reproduction of published and unpublished data obtained with alternative methods and (ii) identify novel imbalances that were not shown before.

Algorithms↗

Separation of phospholipids in microfluidic chip device: application to high-throughput screening assays for lipid-modifying enzymes.

Phospholipid molecules such as ceramide and phosphoinositides play crucial roles in signal transduction pathways. Lipid-modifying enzymes including sphingomyelinase and phosphoinositide kinases regulate the generation and degradation of these lipid-signaling molecules and are important therapeutic targets in drug discovery. We now report a sensitive and convenient method to separate these lipids using microfluidic chip-based technology. The method takes advantage of the high-separation power of the microchips that separate lipids based on micellar electrokinetic capillary chromatography (MEKC) and the high sensitivity of fluorescence detection. We further exploited the method to develop a homogenous assay to monitor activities of lipid-modifying enzymes. The assay format consists of two steps: an on-plate enzymatic reaction using fluorescently labeled substrates followed by an on-chip MEKC separation of the reaction products from the substrates. The utility of the assay format for high-throughput screening (HTS) is demonstrated using phospholipase A(2) on the Caliper 250 HTS system: throughput of 80min per 384-well plate can be achieved with unattended running time of 5.4h. This enabling technology for assaying lipid-modifying enzymes is ideal for HTS because it avoids the use of radioactive substrates and complicated separation/washing steps and detects both substrate and product simultaneously.

Enzymes↗

Whole cell patch clamp recording performed on a planar glass chip.

The state of the art technology for the study of ion channels is the patch clamp technique. Ion channels mediate electrical current flow, have crucial roles in cellular physiology, and are important drug targets. The most popular (whole cell) variant of the technique detects the ensemble current over the entire cell membrane. Patch clamping is still a laborious process, requiring a skilled experimenter to micromanipulate a glass pipette under a microscope to record from one cell at a time. Here we report on a planar, microstructured quartz chip for whole cell patch clamp measurements without micromanipulation or visual control. A quartz substrate of 200 microm thickness is perforated by wet etching techniques resulting in apertures with diameters of approximately 1 microm. The apertures replace the tip of glass pipettes commonly used for patch clamp recording. Cells are positioned onto the apertures from suspension by application of suction. Whole cell recordings from different cell types (CHO, N1E-115 neuroblastoma) are performed with microstructured chips studying K(+) channels and voltage gated Ca(2+) channels.

Animals↗