Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Sampling”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47Linked to original sources

The evaluation of dioxin and dioxin-like contaminants in selected food samples obtained from the Belgian market: comparison of TEQ measurements obtained through the CALUX bioassay with congener specific chemical analyses.

A limited number of different foods were analysed for dioxin-like compounds by the CALUX bioassay which is an in vitro luciferase reporter gene assay measuring chemical activation of the aryl hydrocarbon receptor. Sixty-two milk samples were obtained from a surveillance campaign, 34 meat samples and 34 fishery products were purchased from the Belgian market. Bio-analytical and chemo-analytical dioxin toxicity equivalents (TEQ) values of the same milk samples were compared. Spearman's Rank correlation coefficients of 0.72, 0.67, 0.73 were obtained respectively between CALUX-TEQ and PCDD/F-TEQ, DL-PCB-TEQ and PCDD/F+DL-PCB-TEQ. The bioassay limit of detection was 0.1 pg TEQ from 1 g animal lipid, the limit of quantification was 0.4 pg TEQ. The repeatability of the CALUX bioassay (variability of butter fat samples analysed in the same run) showed a coefficient of variation (CV) of 10%, intra laboratory reproducibility based on independent runs of the same butter fat samples showed more variation (CV of 26% for samples above 2 pg TEQ/g lipid). All milk samples with a chemical TEQ value above the current limit value in Belgium showed an elevated CALUX-TEQ concentration, above 6 pg TEQ/g lipid. No false negative results were obtained. Based on the good correlation between CALUX-TEQ and chemically measured TEQ levels, the CALUX bioassay can be recommended as a screening tool for routine measurement of potentially toxic PHAHs in milk samples. Chemical analyses could then largely be restricted to positive samples, in order to identify the nature and to quantify the concentration of the chemicals that give the positive signal. Meat samples showed lower CALUX-TEQ values per gram lipid compared to fish samples. The fish samples showed a wider range of CALUX-TEQ values than the meat samples.

Belgium↗

Quantitative evaluation of the CEEM soil sampling intercomparison.

The aim of the CEEM soil project was to compare and to test the soil sampling and sample preparation guidelines used in the member states of the European Union and Switzerland for investigations of background and large-scale contamination of soils, soil monitoring and environmental risk assessments. The results of the comparative evaluation of the sampling guidelines demonstrated that, in soil contamination studies carried out with different sampling strategies and methods, comparable results can hardly be expected. Therefore, a reference database (RDB) was established by the organisers, which acted as a basis for the quantitative comparison of the participants' results. The detected deviations were related to the methodological details of the individual strategies. The comparative evaluation concept consisted of three steps: The first step was a comparison of the participants' samples (which were both centrally and individually analysed) between each other, as well as with the reference data base (RDB) and some given soil quality standards on the level of concentrations present. The comparison was made using the example of the metals cadmium, copper, lead and zinc. As a second step, the absolute and relative deviations between the reference database and the participants' results (both centrally analysed under repeatability conditions) were calculated. The comparability of the samples with the RDB was categorised on four levels. Methods of exploratory statistical analysis were applied to estimate the differential method bias among the participants. The levels of error caused by sampling and sample preparation were compared with those caused by the analytical procedures. As a third step, the methodological profiles of the participants were compiled to concisely describe the different procedures used. They were related to the results to find out the main factors leading to their incomparability. The outcome of this evaluation process was a list of strategies and methods, which are problematic with respect to comparability, and should be standardised and/or specified in order to arrive at representative and comparable results in soil contamination studies throughout Europe. Pre-normative recommendations for harmonising European soil sampling guidelines and standard operating procedures have been outlined in Wagner G, Desules A, Muntau H, Theocharopoulos S. Comparative Evaluation of European Methods for Sampling and Sample Preparation of Soils for Inorganic Analysis (CEEM Soil). Final Report of the Contract SMT4-CT96-2085, Sci Total Environ 2001;264:181-186. Wagner G, Desaules A, Munatu H. Theocharopolous S, Quevauvaller Ph. Suggestions for harmonising sampling and sample pre-treatment procedures and improving quality assurance in pre-analytical steps of soil contamination studies. Paper 1.7 Sci Total Environ 2001b;264:103-118.

Environmental Monitoring↗

Evaluation of an indirect ELISA for the diagnosis of bovine brucellosis in milk and serum samples in dairy cattle in Argentina.

An indirect enzyme-linked immunosorbent assay (ELISA) for Brucella abortus antibodies detection in bovine milk and serum samples was validated. The assay use B. abortus smooth lipopolysaccharide as antigen, immobilized on a polystyrene matrix; milk diluted 1:2 or serum diluted 1:50, in a buffer containing divalent cation chelating agents EDTA and EGTA (ethyleneglycol-bis-aminoether-N,N,N',N'-tetraacetic acid) to reduce non-specific reactions; and a mouse monoclonal antibody specific for an epitope of bovine IgG1, conjugated with horseradish peroxidase. A total of 2646 sera and 2119 milk samples from cows older than 24 months were obtained from 12 brucellosis-free herds for at least the previous 5 years. Milk samples were obtained in parallel with serum samples. The remaining 527 serum samples were from dry cows. All cattle were vaccinated with B. abortus strain 19 between 3-10 months of age. Five hundred and fifty-two milk samples and 562 serum samples were obtained from 6 infected herds with abortions where B. abortus was isolated at least once no more than 6 months before sampling. The complement-fixation test (CFT) on serum samples was considered the gold standard. Serum samples were also tested with the official screening test: the buffered plate antigen (BPA) test. The cut-off point was determined using receiver-operating characteristic (ROC) analysis. For milk samples, it was fixed at 36 percent positivity (PP) giving a sensitivity of 99.6% with a 95% confidence interval (CI) of 98.6-99.9%. The specificity was 99.1% (CI 98.9-99.4%). For serum samples, the cut-off was fixed at 53 PP giving a sensitivity of 99.6% (CI 98.6-99.9%) and a specificity 98.6% (CI 98-99%). The BPA test showed a relative sensitivity of 99.6% (CI 98.6-99.9%) and a relative specificity of 98.6% (CI 98.1-99%). Our results indicate that the indirect ELISA is a highly sensitive and specific test and can be adapted to process a large number of samples.

Animals↗

Analysis of drugs and other toxic substances in biological samples for pharmacokinetic studies.

The importance of the role of analysis of drugs and other toxic substances in biological samples (bioanalysis) in medicine, toxicology, pharmacology, forensic science, environmental research and other biomedical disciplines is self-evident. Among these disciplines, bioanalysis plays a special pivotal role in pharmacokinetics. The pharmacokinetic parameters, such as half-life, volume of distribution, clearance and bioavailability, of drugs and other compounds are derived from the concentrations of these analytes assayed in the biological samples collected at specified time points. The capability of analysts to develop sensitive and specific analytical methods for the assay of low concentrations of drugs and other toxic compounds in small amounts of biological samples has contributed significantly to the theoretical advances in pharmacokinetics and its applications in clinical pharmacology and the management of drug therapy in patients. The increased demands for pharmacokinetic applications in turn have stimulated the innovation and improvement in bioanalytical technologies. The reliability of the pharmacokinetic conclusions depends on the accuracy and precision of the analytical methods employed to assay the biological samples. Factors that affect the integrity of the bioanalytical data should therefore be controlled in analysis of biological samples for pharmacokinetics studies. The biological samples for drug concentration determination should be collected as specified in the study protocol with respect to the time and site of sampling. These samples should be processed to avoid extraneous interactions between the analytes and sampling devices or additives resulting in the redistribution of the analytes between components of the biological samples, such as displacement of drug binding and changes in the distribution of the analytes between plasma and red blood cells. The stability of the drugs and other analytes in the samples should also be evaluated to establish the conditions suitable for the transportation and storage of the samples to avoid chemical, photochemical and enzymatic degradation of the analytes. Various technologies have been utilized to assay biological samples for pharmacokinetic studies. The most frequently used are chromatography (high-performance liquid chromatography, gas chromatography and thin-layer chromatography), immunoassays and mass spectrometry.(ABSTRACT TRUNCATED AT 400 WORDS)

Body Fluids↗

An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen.

To measure the speed of sound (SOS), most quantitative ultrasound (QUS) devices use the transmission mode, whereby two transducers are placed on opposite sides of the sample. This mode is limited to a few specific skeletal sites because of the varying configuration of bone geometry and varying amounts of overlying soft tissue at most other sites. The aim of this study was to address the dependence of SOS measured along the sample on the thickness and composition of the bone sample. Bovine samples from mid-femur and trochanter, and perspex phantoms were used. We prepared the perspex samples in the shapes of blocks and cylinders to investigate the effect of wall thickness on SOS. The thickness of the blocks was decreased in decrements of 1 mm; a 22 mm diameter hole was drilled through the cylindrical samples and the hole size was gradually increased. The second configuration was also used with the bovine samples. For each experimental set-up five SOS measurements were acquired, with the probe aligned along the sample and a mean value computed. All measurements were taken with castor oil as the coupling agent, and in the cylindrical cases, the oil was used to fill the tube. The measurement precision determined as the root mean square coefficient of variation (RMSCV) was determined to be 0.14% and 0.65% for perspex and bovine samples respectively. The measured SOS on the perspex phantom (2760+/-4 m/s) was within the published values for bulk velocity. It was observed that for both perspex and bovine samples the SOS was independent of sample wall thickness greater than the wavelength (2.2 mm, 2.7 mm and 3.5 mm for perspex, trochanter and mid-femur respectively). The SOS decreased with sample wall thickness smaller than the wavelength in concordance with theoretical predictions. The SOS values obtained for bovine samples reflected either totally cortical (mid-femur) or a composite of cortical and cancellous bone (trochanter).

Animals↗

Biological sample collection and processing for molecular epidemiological studies.

Molecular epidemiology uses biomarkers and advanced technology to refine the investigation of the relationship between environmental exposures and diseases in humans. It requires careful handling and storage of precious biological samples with the goals of obtaining a large amount of information from limited samples, and minimizing future research costs by use of banked samples. Many factors, such as tissue type, time of collection, containers used, preservatives and other additives, transport means and length of transit time, affect the quality of the samples and the stability of biomarkers and must be considered at the initial collection stage. An efficient study design includes provisions for further processing of the original samples, such as cryopreservation of isolated cells, purification of DNA and RNA, and preparation of specimens for cytogenetic, immunological and biochemical analyses. Given the multiple uses of the samples in molecular epidemiology studies, appropriate informed consent must be obtained from the study subjects prior to sample collection. Use of barcoding and electronic databases allow more efficient management of large sample banks. Development of standard operating procedures and quality control plans is a safeguard of the samples' quality and of the validity of the analyses results. Finally, specific state, federal and international regulations are in place regarding research with human samples, governing areas including custody, safety of handling, and transport of human samples, as well as communication of study results.Here, we focus on the factors affecting the quality and the potential future use of biological samples and some of the provisions that must be made during collection, processing, and storage of samples, based on our experience in the Superfund Basic Research Program and Children's Environmental Health Center, at the University of California, Berkeley.

Humans↗

A novel method to compensate for different amplification efficiencies between patient DNA samples in quantitative real-time PCR.

Quantification of residual disease by real-time polymerase chain reaction (PCR) will become a pivotal tool in the development of patient-directed therapy. In recent years, various protocols to quantify minimal residual disease in leukemia or lymphoma patients have been developed. These assays assume that PCR efficiencies are equal for all samples. Determining t(14;18) and albumin reaction efficiencies for sixteen follicular lymphoma patient samples revealed higher efficiencies for blood samples than for lymph node samples in general. However, within one sample both reactions had equivalent efficiencies. Differences in amplification efficiencies between patient samples (low efficiencies) and the calibrator in quantitative analyses result in the underestimation of residual disease in patient samples whereby the weakest positive patient samples are at highest error. Based on these findings for patient samples, the efficiency compensation control was developed. This control includes two reference reactions in a multiplex setting, specific for the beta-actin and albumin housekeeping genes that are present in a constant ratio within DNA templates. The difference in threshold cycle values for both reference reactions, ie, the Ct(2) value, is dependent on the amplification efficiency, and is used to compensate for efficiency differences between patient samples and the calibrator. The beta-actin reference reaction is also used to normalize for DNA input. Furthermore, the efficiency compensation control facilitates identification of patient samples that are so contaminated with PCR inhibitory compounds that different amplification reactions are affected to a different extent. Accurate quantitation of residual disease in these samples is therefore impossible with the current quantitative real-time PCR protocols. Identification and exclusion of these inadequate samples will be of utmost importance in quantitative retrospective studies, but even more so, in future molecular diagnostic analyses.

Actins↗

Development of a method for dioxin analysis of small serum samples with reduced risk of volatilization.

To analyze the dioxin content of samples, including dibenzo-p-dioxins/dibenzofurans, and coplanar polychlorinated biphenyls (Co-PCBs), a large volume is usually necessary. This is difficult, however, when analyzing clinical samples, such as serum and tissue. We therefore sought to increase the sensitivity of high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS) in analyzing dioxins by injecting most of the extract from a small clinical sample. The concentration of each congener was estimated by injecting extracts of 5-g samples into a gas chromatography capillary precolumn (AT column) and by assaying extracts of 25-g samples by conventional splitless methods. We found that the limit of detection with the AT column was lower than that obtained by the splitless technique. In the AT column technique, 100 microL of the 110-microL final solution, equivalent to 4.5 g of the original sample, was injected into HRGC/HRMS. In contrast, 2 microL of the 20-microL final solution, equivalent to 2.5 g of original sample, was assayed using the splitless method. Moreover, when 25 fg of ultratrace dioxin was added to 100 microL of HRGC/HRMS sample and injected into the AT column, the peak area was almost the same as that obtained with 2 microL of HRGC/HRMS sample injected using the splitless method. Although assaying 10-20 microL of sample by the splitless method presents difficulties due to sample volatility, this problem can be reduced by using volumes larger than 100 microL. We tested this application by quantifying the parts-per-trillion levels, on a lipid weight basis, of each congener in a serum sample of 5 g using the AT column HRGC/HRMS method. We found this application to be successful and practical for mass screening of dioxin exposure in clinical samples.

Dioxins↗

A 96-well screen filter plate for high-throughput biological sample preparation and LC-MS/MS analysis.

A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples--to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.

Automation↗

Atypical "tails-up" capnograph due to breach in the sampling tube of side-stream capnometer.

OBJECTIVE: An atypical "tails-up" capnograph pattern was noticed in a patient during the use of an accidentally crushed sampling tube with a slit-like hole. We investigated the mechanics involved in the observed capnograph pattern. METHODS: Forty consenting ASA I patients of both sexes presenting for tonsillectomy were included in this study. After intravenous induction of anaesthesia, intermittent positive pressure ventilation (IPPV) using a mechanical ventilator was maintained for 20 min and the capnograph trace, ETCO2, and inspiratory/expiratory sevoflurane were compared using a breached sampling tube and then an intact sampling tube. Similar comparisons were made during spontaneous breathing. RESULTS: During IPPV, an atypical "tails-up" capnograph was noted using the breached sampling tubing. At similar inspiratory sevoflurane (2.0 +/- 0.03) levels, expiratory levels (0.9 +/- 0.03) were significantly lower when using the breached sampling tube than the intact tube (1.7 +/- 0.03). ETCO2 with the breached sampling tube (26.8 +/- 0.30 mmHg) showed significantly lower values than with the intact sampling tube (37 +/- 0.3). During spontaneous breathing, the capnograph was normal in shape with both sampling tubes, but ETCO2 and both insp./exp. sevoflurane levels were lower with the breached sampling tube. CONCLUSION: During IPPV, pressure in the breathing circuit is lower during exhalation, thus allowing air to enter through the slit-like hole in the sampling tube causing erroneously low ETCO2 and expiratory sevoflurane. With inspiration, positive pressure in the breathing circuit, transmitted to the sampling tube, prevents air admixture and the upsurge in CO2 is displayed giving the capnograph an atypical "tails-up" appearance. During spontaneous breathing, since pressure in the breathing circuit barely becomes positive during exhalation and is negative during inspiration, air mixes with the sampled gas during both phases and so the capnograph shape was normal but with lower values for ETCO2, insp./exp. sevoflurane, and nitrous oxide levels. If undiagnosed, this defect in the sampling tube can lead to significant errors in the measurement of inspired and expired gas concentrations.

Adolescent↗

Field measurement of lead in workplace air and paint chip samples by ultrasonic extraction and portable anodic stripping voltammetry.

On-site measurement of lead in workplace air filter samples and paint chip samples by ultrasonic extraction and anodic stripping voltammetry (UE-ASV) was evaluated in the field during renovation and remodeling activities in residences having leaded paint. Aerosol and paint samples were collected using standard techniques, and the samples were analyzed on-site for lead content by portable UE-ASV. Lead in sample extracts was subsequently determined by atomic absorption (AA) spectrometry in a fixed-site laboratory. The remaining sample extracts plus undissolved material (air filters or paint particles) were then subjected to hot plate digestion in concentrated nitric acid-30% hydrogen peroxide prior to AA analysis for lead. Field UE-ASV lead data were thereby compared to UE-AA and hot plate digestion-AA results from fixed-site laboratory lead measurement. Determination of lead in air filter samples by UE-ASV (over the range of 5 microg to approximately 800 microg Pb per sample) was extremely well correlated with lead measurement by UE-AA and hot plate digestion-AA procedures. However, a significant negative bias associated with ASV measurement was observed, and this was attributed to a matrix effect. Lead measurement in paint chip samples by UE-ASV (over the range of approximately 10 to approximately 550 microg Pb g(-1)) was well correlated with lead measurement by UE-AA and hot plate digestion-AA procedures. However, correlation and precision were lower for lead measurement in paint samples as compared to aerosol samples, and a negative bias was also observed. Lead measurements by UE-AA were compared to lead determinations by hot plate digestion-AA; these data were highly correlated and demonstrated no significant bias. Thus it was concluded that the ultrasonic extraction procedure performed equivalently to hot plate digestion. It was reasoned that matrix effects due to the preparation and analysis of paint chip particles resulted in greater imprecision as well as negative bias by ASV measurement. Despite significant negative bias in this sample set, UE-ASV offers promise for on-site measurement of lead in samples of interest in occupational and environmental health.

Air Pollution, Indoor↗

The quality of the fossil record and the accuracy of phylogenetic inferences about sampling and diversity.

Because phylogenies can be estimated without stratigraphic data and because estimated phylogenies also infer gaps in sampling, some workers have used phylogeny estimates as templates for evaluating sampling from the fossil record and for "correcting" historical diversity patterns. However, it is not known how sampling intensity (the probability of sampling taxa per unit time) and completeness (the proportion of taxa sampled) affect the accuracy of phylogenetic inferences, nor how phylogenetically inferred estimates of sampling and diversity respond to inaccurate estimates of phylogeny. Both issues are addressed with a series of simulations using simple models of character evolution, varying speciation patterns, and various rates of speciation, extinction, character change, and preservation. Parsimony estimates of simulated phylogenies become less accurate as sampling decreases, and inaccurate trees chronically underestimate sampling. Biotic factors such as rates of morphologic change and extinction both affect the accuracy of phylogenetic estimates and thus affect estimated gaps in sampling, indicating that differences in implied sampling need not reflect actual differences in sampling. Errors in inferred diversity are concentrated early in the history of a clade. This, coupled with failure to account for true extinction times (i.e., the Signor-Lipps effect), inflates relative diversity levels early in clade histories. Because factors other than differences in sampling predict differences in the numbers of gaps implied by phylogeny estimates, inferred phylogenies can be misleading templates for evaluating sampling or historical diversity patterns.

Fossils↗

The efficacy and safety of blood sampling through peripherally inserted central catheter devices in children.

BACKGROUND: The peripherally inserted central catheter (PICC) is commonly used in children for medication and fluid administration. In addition, PICCs are used occasionally for blood sampling as an alternative to venipuncture. Blood sampling from these catheters carries the hypothetical risk of catheter occlusion caused by blood remaining in the catheter, and this practice is not supported by PICC manufacturers. Children often undergo multiple needle punctures, which are associated with pain, anxiety, and dissatisfaction with care. The authors hypothesized that blood sampling through 3-Fr PICC devices is effective and safe for children. METHODS: After placement of a 3-Fr PICC, all the children were sequentially enrolled in one of two groups. The control group included patients that had 3-Fr PICC devices without blood sampling. The blood sampling group included patients with 3-Fr PICC devices through which blood samples were obtained. Demographic data, PICC placement and sampling data, infusate composition, catheter occlusion, mechanical complications, and blood stream infections were recorded. The primary outcome variable was the difference in occlusion rates between the two groups. RESULTS: The analysis included 204 children with 3-Fr PICCs (120 in the blood sampling group and 84 in the control group) who had a mean age, 117.7 +/- 4.9 months. The mean PICC duration was 15.6 +/- 1.0 days. Blood sampling was successful more than 98% of the time from all blood sampling group catheters, with a mean of 4.4 +/- 0.5 samples removed from each catheter. There was a higher occlusion rate in the blood sampling group. However, this result did not reach statistical significance. There were no significant differences between the groups in terms of infection or mechanical complication rates. CONCLUSIONS: Blood sampling is feasible and effective through 3-Fr PICC devices in children. This practice is not associated with a significant increase in occlusion, infection, or mechanical complication rates.

Age Factors↗

Oropharyngeal samples for genotyping and monitoring response to treatment in AIDS patients with Pneumocystis carinii pneumonia.

A nested PCR, amplifying a portion of the gene encoding the mitochondrial large subunit ribosomal RNA (mt LSU rRNA) of Pneumocystis carinii sp. f. hominis was applied to oropharyngeal samples obtained on repeated occasions from 12 HIV-infected patients with P. carinii pneumonia (PCP) to monitor response to anti-P. carinii treatment. Genotyping of P. carinii sp. f. hominis was also performed on paired samples of oropharyngeal and broncho-alveolar lavage samples before the start of treatment, and on oropharyngeal samples during the course of treatment, by analysis of sequence variation at the internal transcribed spacer (ITS) regions of the nuclear rRNA operon. When a simple dilutional method was used, a reduction in the amount of amplification product was observed in samples from all patients during the course of treatment. In eight of the 12 patients, a single ITS sequence type was found in the oropharyngeal samples and also in the paired broncho-alveolar lavage sample. A mixed infection was identified in the samples from three patients. In eight patients, the ITS sequence types identified in the oropharyngeal sample were the same as in the broncho-alveolar lavage sample. Nested PCR amplifying the mt LSU rRNA on oropharyngeal samples provides a non-invasive method of monitoring response to treatment of PCP. ITS sequence typing of P. carinii sp. f. hominis from oropharyngeal samples appears to be a reliable alternative to broncho-alveolar lavage samples and provides a non-invasive tool for further epidemiological studies.

AIDS-Related Opportunistic Infections↗

Concentrations of cat and dust-mite allergens in dust samples from 92 large US office buildings from the BASE Study.

UNLABELLED: The concentrations of cat (Fel d1) and dust-mite (Der f1 and Der p1) allergens were measured in 92 large office buildings in the US Environmental Protection Agency's Building Assessment Survey and Evaluation (BASE) Study (251 dust samples; one to four samples per building). Fel d1 was detected in almost all buildings and samples (91 buildings, 99%; 235 samples, 94%; range: <0.01-19 microg/g; median: 0.3 microg/g). Cat allergen exceeded 1 microg/g (a lower symptom threshold) in 56 samples (22%) from 45 buildings, but exceeded 8 microg/g (a sensitization threshold) in only two samples (1%) from two buildings. Der f1 or Der p1 was found in approximately half of all buildings and samples (63 and 70% of buildings; 45 and 51% of samples; range: <0.01-53 microg/g and <0.01-25 microg/g; median: <0.02 and 0.03 microg/g, respectively). Mite allergen exceeded 2 microg/g (a sensitization threshold) in seven samples (3%) from five buildings and exceeded 10 microg/g (a symptom threshold) in three samples (1%) from three buildings. Fel d1 concentration was significantly higher in samples collected in summer (June to September, 48 buildings), but cat allergen was not correlated with either mite allergen. Der f1, but not Der p1, concentration tended to be higher in samples collected in winter (December to April, 44 buildings), and the two mite allergens were significantly correlated only in winter. Cat and mite allergens were detected in 78% of representative US office buildings, but the concentrations seldom exceeded levels associated with sensitization or symptom provocation. PRACTICAL IMPLICATIONS: The information on the concentrations of cat and dust-mite allergens in representative large US offices has expanded the baseline data available for interpretation of measurements from other building investigations. With suggested refinements, the BASE protocol for measurement of allergen concentrations in dust samples may serve as a guide to future studies of building characteristics, bioaerosol concentrations, and occupant perceptions of the indoor environment.

Air Microbiology↗

Natural occurrence of Fusarium mycotoxins in field samples from the 1992 Wisconsin corn crop.

Analysis of 98 moldy corn samples collected in Wisconsin between November 1992 and January 1993 for Fusarium toxins by various immunochemical assays revealed overall average mycotoxin concentrations of 305.6, 237.7, and 904.3 ng/g for type A trichothecenes (TCTCs), deoxynivalenol (DON)-related type B TCTCs (total DON), and zearalenone (ZE), respectively. A small portion (5.1%) of the samples was found to be contaminated with high levels ( > 1 microgram/g) of type A TCTCs and total DON during the whole survey. Over 40% of the samples had 100 to 1,000 ng of total DON per g, while 17% of the samples had the same levels of type A TCTCs. The analytical data were consistent with those from mycological examinations for the samples in which various toxic Fusarium spp., including F. sporotrichioides, F. poae, and F. graminearum, were found. The samples received in November 1992 had relatively low concentrations of toxin; the average levels of type A TCTCs and total DON were 9.9 and 79 ng/g, respectively. The toxin concentrations became progressively higher in the samples received in December. The average levels for the type A TCTCs and total DON increased to 920 and 335 ng/g, respectively. However, the levels of ZE were higher in the samples collected earlier. The average levels for samples collected in November and late December were 1,195 and 242 ng/g, respectively. Analysis of selected samples by high-performance liquid chromatography monitoring with an enzyme-linked immunosorbent assay revealed that T-2 toxin, HT-2 toxin, diacetoxyscirpenol, neosolaniol, and T-2 tetraol (T-2-4ol) were common in these samples. Statistical analysis revealed a weak correlation between the levels of total type A TCTCs and total DON in the samples (r = 0.18, P = 0.09), but a strong correlation between the levels of ZE and total type B TCTCs (r = 0.75, P < 0.0001) was found. The mycotoxin levels of total type A TCTCs, total DON-related type B TCTCs, and ZE in the cobs (5.2, 3.9, and 21 micrograms/g, respectively) were considerably higher than those in the kernels (1.0, 0.5, and 0.5 microgram/g, respectively). The type A toxin levels increased from a range of 14 to 35 ng/g to a range of 110 to 538 ng/g after the moldy corn samples were held at 5 degrees C for 8 days in the laboratory.

Food Microbiology↗

Comparative analysis of ACTH and corticosterone sampling methods in rats.

A frequently debated question for studies involving the measurement of stress hormones in rodents is the optimal method for collecting blood with minimal stress to the animal. Some investigators prefer the implantation of indwelling catheters to allow for frequent sampling. Others argue that the implantation of a catheter creates a chronic stress to the animal that confounds stress hormone measures and therefore rely on tail vein sampling. Moreover, some investigators measure hormones in trunk blood samples obtained after anesthesia, a practice that may itself raise hormone levels. To address these controversies, we 1) compared plasma ACTH and corticosterone (Cort) concentrations in pre- and poststress rat blood samples obtained via previously implanted vena cava catheters, tail vein nicks, or clipping the tip off the tail and 2) compared plasma ACTH and Cort in rat blood samples obtained by decapitation with and without anesthesia. Rats sampled via indwelling catheters displayed lower prestress ACTH levels than those sampled by tail vein nick if the time to acquire samples was not limited; however, elevated basal ACTH was not observed in samples obtained by tail clip or tail nick when the samples were obtained within 3 min. Baseline Cort levels were similar in all groups. After restraint stress, the profile of the plasma ACTH and Cort responses was not affected by sampling method. Decapitation with prior administration of CO2 or pentobarbital sodium increased plasma ACTH levels approximately 13- and 2-fold, respectively, when compared with decapitation without anesthesia. These data indicate that tail vein nicking, tail clipping, or indwelling venous catheters can be used for obtaining plasma for ACTH and Cort during acute stress studies without confounding the measurements. However, the elevation in basal ACTH seen in the tail vein nick group at baseline suggests that sampling needs to be completed rapidly (<3 min) to avoid the initiation of the pituitary stress response. Death by CO2 and pentobarbital sodium injection before trunk blood collection cause significant stress to animals, as reflected in the elevated plasma ACTH levels. These results support the use of either chronic vascular cannulas or sampling from a tail vein. However, collection of blood under pentobarbital sodium or CO2 anesthesia is likely to confound the results of stress studies when ACTH is an important endpoint.

Adrenocorticotropic Hormone↗

Observed intra-cluster correlation coefficients in a cluster survey sample of patient encounters in general practice in Australia.

BACKGROUND: Cluster sample study designs are cost effective, however cluster samples violate the simple random sample assumption of independence of observations. Failure to account for the intra-cluster correlation of observations when sampling through clusters may lead to an under-powered study. Researchers therefore need estimates of intra-cluster correlation for a range of outcomes to calculate sample size. We report intra-cluster correlation coefficients observed within a large-scale cross-sectional study of general practice in Australia, where the general practitioner (GP) was the primary sampling unit and the patient encounter was the unit of inference. METHODS: Each year the Bettering the Evaluation and Care of Health (BEACH) study recruits a random sample of approximately 1,000 GPs across Australia. Each GP completes details of 100 consecutive patient encounters. Intra-cluster correlation coefficients were estimated for patient demographics, morbidity managed and treatments received. Intra-cluster correlation coefficients were estimated for descriptive outcomes and for associations between outcomes and predictors and were compared across two independent samples of GPs drawn three years apart. RESULTS: Between April 1999 and March 2000, a random sample of 1,047 Australian general practitioners recorded details of 104,700 patient encounters. Intra-cluster correlation coefficients for patient demographics ranged from 0.055 for patient sex to 0.451 for language spoken at home. Intra-cluster correlations for morbidity variables ranged from 0.005 for the management of eye problems to 0.059 for management of psychological problems. Intra-cluster correlation for the association between two variables was smaller than the descriptive intra-cluster correlation of each variable. When compared with the April 2002 to March 2003 sample (1,008 GPs) the estimated intra-cluster correlation coefficients were found to be consistent across samples. CONCLUSIONS: The demonstrated precision and reliability of the estimated intra-cluster correlations indicate that these coefficients will be useful for calculating sample sizes in future general practice surveys that use the GP as the primary sampling unit.

Australia↗